Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 653-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16604719

RESUMO

A study of differential photo-neutron yields by irradiation with 2 GeV electrons has been carried out. In this extension of a previous study in which measurements were made at an angle of 90 degrees relative to incident electrons, the differential photo-neutron yield was obtained at two other angles, 48 degrees and 140 degrees, to study its angular characteristics. Photo-neutron spectra were measured using a pulsed beam time-of-flight method and a BC418 plastic scintillator. The reliable range of neutron energy measurement was 8-250 MeV. The neutron spectra were measured for 10 Xo-thick Cu, Sn, W and Pb targets. The angular distribution characteristics, together with the previous results for 90 degrees, are presented in the study. The experimental results are compared with Monte Carlo calculation results. The yields predicted by MCNPX 2.5 tend to underestimate the measured ones. The same trend holds for the comparison results using the EGS4 and PICA3 codes.


Assuntos
Modelos Estatísticos , Nêutrons , Aceleradores de Partículas , Fótons , Proteção Radiológica/métodos , Radiometria/métodos , Simulação por Computador , Elétrons , Doses de Radiação , Espalhamento de Radiação
2.
Radiat Prot Dosimetry ; 115(1-4): 623-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16381795

RESUMO

Precise estimation of induced activities in concrete shields for high-energy accelerator facilities is one of the most important issues that need to be solved, not only for the reduction of exposure for workers, but also for the reduction of radioactive wastes. Irradiation experiments have been performed by using the 500 MeV Neutron Spallation Source Facility in KEK. The large concrete assembly was placed in the direction of 0 degrees to the beamline. Two kinds of samples were placed at several positions in the assembly. The irradiation period was about 1 week and induced activities in the samples were measured until approximately 1.5 y after irradiation. From the comparison between the experiment and the available Monte Carlo calculation code system, good agreement was obtained for 24Na, 47Sc, 47Ca and 54Mn within a factor 2; however, large discrepancies were observed for some other nuclides.


Assuntos
Materiais de Construção/análise , Transferência Linear de Energia , Nêutrons , Aceleradores de Partículas/instrumentação , Proteção Radiológica/instrumentação , Radiometria/métodos , Simulação por Computador , Análise de Falha de Equipamento , Teste de Materiais , Modelos Estatísticos , Doses de Radiação , Proteção Radiológica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA