Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Assunto principal
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Mikrochim Acta ; 190(10): 386, 2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37700059

RESUMO

The development of a sensitive and selective electrochemical sensor for simultaneous quantification of manganese (Mn(II)) and chromium (Cr(VI)) using composite of graphene oxide (GO) and manganese oxide modified screen printed carbon electrode (GO-Mn2O3/SPCE) is reported for the first time. The good sensing performance is achieved by mixing GO prepared by modified Hummer's method (GO-H) with proper particle size of Mn2O3 (241 nm). The mechanism of this sensor is based on the formation of Mn-O and Cr-O on the modified electrode with assistance of oxygen moieties provided by both Mn2O3 NPs and GO. The analytical performances were investigated by measuring electrochemical signal of Mn(II) and Cr(VI) by using square-wave cathodic stripping voltammetry (SWCSV). This sensor holds low electrode-to-electrode variation (relative standard deviation (RSD) < 4%) with a good limit of detection (LOD) at about 6.67 and 11.20 µg⋅L-1 for Mn(II) and Cr(VI), respectively. Applicability of this sensor was demonstrated by measuring Mn(II) and Cr(VI) in tap water samples with recovery of 90.77-103.45% and 82.34-103.73% for Mn(II) and Cr(VI) determinations, respectively. With the contribution of both GO and Mn2O3 as electrocatalysts, this developed sensor is capable to be used for water quality monitoring in real samples.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38928976

RESUMO

A recent study conducted in Khon Kaen Province, Thailand, evaluated the effectiveness of a technology-assisted intervention aimed at improving water quality and addressing related health issues in communities around key water bodies. The intervention targeted health concerns associated with water contamination, including chronic kidney diseases, skin conditions, hypertension, and neurological symptoms. The study included water quality assessments and health evaluations of 586 residents and implemented a Learning Innovation Platform (LIP) across 13 communities. Results showed significant improvements in the community, including a decrease in hypertension and skin-related health issues, as well as enhanced community awareness and proficiency in implementing simple water quality assessments and treatment. The study demonstrated the value of a comprehensive, technology-driven community approach, effectively enhancing water quality and health outcomes, and promoting greater community awareness and self-sufficiency in managing environmental health risks.


Assuntos
Qualidade da Água , Tailândia , Humanos , Feminino , Masculino , Adulto , Poluição da Água , Pessoa de Meia-Idade , Dermatopatias/terapia
3.
RSC Adv ; 10(17): 9884-9893, 2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-35498601

RESUMO

This article reports the first fluorescent distance-based paper device coupled with an evaporating preconcentration system for determining trace mercury ions (Hg2+) in water. The fluorescent nitrogen-doped carbon dots (NCDs) were synthesized by a one-step microwave method using citric acid and ethylenediamine. The fluorescence turn-off of the NCDs in the presence of Hg2+ was visualized with a common black light, and the distance of the quenched fluorescence correlated to Hg2+ concentration. The optimal conditions for pH, NCD concentration, sample volume, and reaction time were investigated. Heating preconcentration was used to improve the detection limits of the fluorescent distance-based paper device by a factor of 100. Under the optimal conditions, the naked eye limit of detection (LOD) was 5 µg L-1 Hg2+. This LOD is sufficient for monitoring drinking water where the maximum allowable mercury level is 6 µg L-1 as established by the World Health Organization (WHO). The fluorescent distance-based paper device was successfully applied for Hg2+ quantification in water samples without interference from other cations. The proposed method provides several advantages over atomic absorption spectroscopy including ease of use, inexpensive material and fabrication, and portability. In addition, the devices are simple to fabricate and have a long shelf-life (>5 months).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA