Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Ann Vasc Surg ; 71: 273-279, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32890647

RESUMO

BACKGROUND: Fusion imaging makes it possible to improve endovascular procedures and is mainly used in hybrid rooms for aortic procedures. The objective of this study was to evaluate the feasibility of fusion imaging for femoropopliteal endovascular procedures with a mobile flat plane sensor and dedicated software to assist endovascular navigation. MATERIALS AND METHODS: Between May and December 2017, 41 patients requiring femoropopliteal endovascular revascularization were included. Interventions were carried out in a conventional surgical room equipped with a mobile plane sensor (Cios Alpha, Siemens). The numerical video stream was transmitted to an angionavigation station (EndoNaut (EN), Therenva). The software created an osseous and arterial panorama of the treated limb from the angiographies carried out at the beginning of procedure. After each displacement of the table, the software relocated the current image on the osseous panorama, with 2D-2D resetting, and amalgamated the mask of the arterial panorama. The success rates of creation of osseous and arterial panorama and the success of relocation were evaluated. The data concerning irradiation, the volume of contrast (VC) injected, and operative times were recorded. RESULTS: Osseous panoramas could be automatically generated for the 41 procedures, without manual adjustment in 33 cases (80.5%). About 35 relocations based on a 2D-2D resetting could be obtained in the 41 procedures, with a success rate of 85%. The causes of failure were a change in table height or arch angulation. The average duration of intervention was 74.5 min. The irradiation parameters were duration of fluoroscopy 17.8 ± 13.1 min, air kerma 80.5 ± 68.4 mGy, and dose area product 2140 ± 1599 µGy m2. The average VC was 24.5 ± 14 mL. CONCLUSIONS: This preliminary study showed that fusion imaging is possible in a nonhybrid room for peripheral procedures. Imagery of mobile C-arms can be improved for femoropopliteal endovascular procedures without heavy equipment. These imagery tools bring an operative comfort and could probably reduce irradiation and the injected VC. The clinical benefit must be evaluated in more patients in a randomized comparative study with a rigorous methodology.


Assuntos
Angiografia/instrumentação , Procedimentos Endovasculares/instrumentação , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/instrumentação , Terapia Assistida por Computador/instrumentação , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Radiografia Intervencionista/efeitos adversos , Software , Fatores de Tempo , Resultado do Tratamento
2.
J Vasc Interv Radiol ; 30(9): 1386-1392, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31155497

RESUMO

PURPOSE: To quantify the displacement of the vascular structures after insertion of stiff devices during endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm and to identify potential parameters influencing this displacement. MATERIALS AND METHODS: A total of 50 patients from a single center undergoing EVAR were prospectively enrolled between January 2016 and December 2017. Fusion imaging was employed using the EndoNaut (Therenva, Rennnes, France) station through a 3-dimensional (3D)/2-dimensional (2D) technology synchronizing the 3D computed tomography scan to the live intraoperative fluoroscopy. The accuracy of the fusion roadmap was evaluated before deployment by conventional digital subtraction angiogram on a single plane (with different C-arm incidences). RESULTS: The mean displacement error of the ostium of the lowest renal artery was 4.1 ± 2.4 mm (range, 0-11.7 mm), with a left/right displacement of 1.6 ± 1.7 mm (range, 0-6.9 mm) and a craniocaudal displacement of 3.5 ± 2.4 mm (range, 0-11.3 mm). The correction required for the ostium of the lower renal artery was mostly cranial and to the left. Multiple linear regression analysis revealed only the sharpest angle between the aneurysm neck and sac as the factor influencing the accuracy of fusion imaging. All other parameters did not show any correlation. CONCLUSIONS: This study identified the sources of fusion error after insertion of rigid material during EVAR. As the sharpest angulation between aneurysm neck and sac increases, the overall accuracy of the fusion might be affected.


Assuntos
Angiografia Digital , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Stents , Resultado do Tratamento
3.
Int J Numer Method Biomed Eng ; 37(1): e03409, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33098246

RESUMO

Fenestrated endovascular aneurism repair (FEVAR) is a minimally invasive technique, and its success depends on the adequacy of the correspondence between the visceral arteries ostia and position of the fenestrations of the stent graft (SG) during its deployment in juxtarenal aneurisms. However, the fenestration position is generally determined from a preoperative computerised tomography (CT) scan, without considering the vascular deformation induced by the insertion of the endovascular tools. Catheterisation difficulties may occur during clinical procedures. Accordingly, the objective of this work is to present an initial proof of concept aimed at anticipating and optimising the position of the fenestrations, while considering the vascular deformation induced by the insertion of the endovascular tools. The proposed method relies on the finite element method to simulate the SG deployment in a vascular structure (VS), and considers the vascular deformation induced by the tools. After determining the optimal simulation parameters for a patient-specific case, the robustness of the method is demonstrated on six other representative anatomies. The simulated SG is also compared with post-deployment CT observations, and demonstrates good adequacy. The results show that the numerically corrected fenestration positions, as determined from the simulated results following the insertion of the endovascular tools, deviate from those of the standard plan (as determined from the preoperative CT scan). This indicates that the SG-VS adequacy could be improved via simulation-based planning, to anticipate potential catheterisation difficulties.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Humanos , Desenho de Prótese , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA