RESUMO
AIMS: Studies assessing transfemoral transcatheter aortic valve implantation (TF-TAVI) showed lower rates of in-hospital mortality at high-volume hospitals and minimum caseloads were recommended to assure quality standards. METHODS AND RESULTS: All patients in the German mandatory quality assurance registry with elective or urgent TF-TAVI procedures in 2018 and 2019 at 81 and 82 hospitals, respectively, were analysed. Observed in-hospital mortality was adjusted to expected mortality by the German AKL-KATH score (O/E) as well as by the EuroScore II (O/E2). Hospital volume and O/E were correlated by regression analyses and volume quartiles. 18 763 patients (age: 81.1 ± 1.0 years, mean EuroSCORE II: 6.9 ± 1.8%) and 22 137 patients (mean age: 80.7 ± 3.5 years, mean EuroSCORE II: 6.5 ± 1.6%) were analysed in 2018 and 2019, respectively. The average observed in-hospital mortality was 2.57 ± 1.83% and 2.36 ± 1.60%, respectively. Unadjusted in-hospital mortality was significantly inversely related to hospital volume by linear regression in both years. After risk adjustment, the association between hospital volume and O/E was statistically significant in 2019 (R2 = 0.049; P = 0.046), but not in 2018 (R2 = 0.027; P = 0.14). The variance of O/E explained by the number of cases in 2019 was low (4.9%). Differences in O/E outcome between the first and the fourth quartile were not statistically significant in both years (1.10 ± 1.02 vs. 0.82 ± 0.46; P = 0.26 in 2018; 1.16 0 .97 vs. 0.74 ± 0.39; P = 0.084 in 2019). Any chosen volume cut-off could not precisely differentiate between hospitals with not acceptable quality (>95th percentile O/E of all hospitals) and those with acceptable (O/E ≤95th percentile) or above-average (O/E < 1) quality. For example, in 2019 a cut-off value of 150 would only exclude one of two hospitals with not acceptable quality, while 20 hospitals with acceptable or above-average quality (25% of all hospitals) would be excluded. CONCLUSION: The association between hospital volume and in-hospital mortality in patients undergoing elective TF-TAVI in Germany in 2018 and 2019 was weak and not consistent throughout various analytical approaches, indicating no clinical relevance of hospital volume for the outcome. However, these data were derived from a healthcare system with restricted access to hospitals to perform TAVI and overall high TAVI volumes. Instead of the unprecise surrogate hospital volume, the quality of hospitals performing TF-TAVI should be directly assessed by real achieved risk-adjusted mortality.
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Humanos , Idoso , Idoso de 80 Anos ou mais , Mortalidade Hospitalar , Hospitais com Alto Volume de Atendimentos , Alemanha/epidemiologiaRESUMO
BACKGROUND: Transcatheter aortic valve implantation (TAVI) for aortic stenosis in older patients is the standard of care with a well-established supply density in Germany. In the near future, healthcare reform is planned that may affect TAVI capacities. Therefore, it is important to know how political regulations may interfere with access to services and what the need for TAVI will be in the future, based on demographic trends. METHODS: The number of TAVI procedures (DRG F98Aâ¯+F98) and the in-hospital main diagnoses of aortic stenosis (ICD I35) in 2021 were analyzed at the level of county or federal state based on anonymized data from hospital reports, according to § 21 of the German hospital reimbursement law. The number of TAVI and aortic stenosis cases was projected for 2035 based on data from the German Federal Statistical Office on demographic developments. With quality assurance data from hospitals in 2019 and a route planner, the travel time to the next hospital performing TAVI (OPS 535a.0) was calculated, and the consequence of a politically suggested minimum volume cut-off was analyzed. RESULTS: In 2021, a total of 26,506 TAVI procedures were reported with a mean number of TAVI per 100,000 inhabitants of 32 (range between federal states from 25 to 42). Among the 66,045 diagnoses of aortic stenosis, there was a variation per 100,000 inhabitants from 64 to 108 (mean 79) between federal states. Compared to 2021, an additional 8748 (+13%) diagnoses of aortic stenosis and an increase of 4673 (+18%) TAVI procedures is to be expected in 2035. In 2019, 57% of German citizens could reach a TAVI hospital within 30â¯min and 91% within 60â¯min of driving time by car (mean time to hospital 31â¯min). Applying a minimum number of 150 TAVI/hospital per year would increase the driving time to hospital from 33 to 52â¯min in Saxony-Anhalt and instantly remove six out of eight hospitals from service in Hesse. CONCLUSION: Regulation of TAVI services by minimum volume numbers would arbitrarily interfere with access to services, in contradiction to the medical service assurance tasks of federal state governments. These issues should be considered in the upcoming healthcare system reform.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco , Resultado do Tratamento , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Alemanha/epidemiologia , Atenção à SaúdeRESUMO
BACKGROUND: Current guidelines recommend dual antiplatelet therapy (DAPT) following percutaneous coronary intervention for 6-12 months in patients with acute coronary syndrome (ACS) and 3-6 months in those with chronic coronary syndromes (CCS). Whether DAPT duration has a differential effect on outcomes following treatment of ischemic coronary disease with durable versus biodegradable drug-eluting stent (DES) is poorly defined. METHODS: The TARGET All Comer study was a randomized trial of patients with ischemic coronary artery disease assigned to treatment with either a biodegradable polymer DES (Firehawk) or a durable polymer DES (XIENCE). This pre-specified TARGET AC sub-analysis sought to evaluate the 2-year clinical outcomes before and after DAPT discontinuation. The primary endpoint was target lesion failure (TLF). RESULTS: A total of 1,296 (78.4%) of 1,653 randomized patients were included in this substudy, of which 1,210 (93.4%) remained on DAPT at 6 months, 863 (66.6%) at 12 months, and 409 (31.6%) at 2 years. There was no difference in TLF between patients treated with Firehawk and XIENCE stents from index procedure to DAPT discontinuation (8.0 and 7.7%, p > .99) or after DAPT discontinuation (2.9 vs. 3.8%, p = .16). After DAPT discontinuation, target vessel myocardial infarction (1.3 vs. 3.3%, p = .07), and ischemia-driven target lesion revascularization (0.5 vs. 1.9%, p = .06) favored treatment with Firehawk. CONCLUSIONS: Although TLF was comparable for both Firehawk and XIENCE stent groups before and after DAPT discontinuation, after DAPT discontinuation, there was a trend for less target vessel myocardial infarction and ischemia-driven revascularization with the biodegradable polymer DES.
Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/terapia , Everolimo/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Polímeros , Sirolimo/efeitos adversos , Resultado do TratamentoRESUMO
Coronary artery bypass grafting (CABG) via full sternotomy remains a very invasive procedure, often requiring prolonged recovery of the patient. We describe a novel, less invasive approach for totally arterial CABG via a small left anterior thoracotomy in a pilot series of 20 unselected patients. From January to March 2020, 20 consecutive patients (mean age 65.9 ± 9.2 years, 100% male, STS-score: 1.6 ± 2) underwent CABG using only arterial conduits via a small left anterior thoracotomy. Patients were operated on cardiopulmonary bypass with peripheral cannulation and transthoracic aortic cross-clamping. Pulling tapes encircling the great vessels, the arrested empty heart was rotated and moved within the pericardium to enable conventional anastomotic techniques especially on lateral and inferior wall coronary targets. In all patients, left internal mammary artery and radial artery were utilized for bypass with 3.3 ± 0.7 distal coronary anastomoses per patient. Anterior, lateral, and inferior wall territories were revascularized in 100%, 85%, and 70% of patients, respectively. Complete anatomical revascularization was achieved in 95% of patients. ICU stay was 1 day in 17 patients, and 14 of patients left the hospital within 8 days. There was no hospital death, no stroke, no myocardial infarction, and no repeat revascularization. In this pilot series of 20 patients, minimally invasive, totally arterial CABG with avoidance of sternotomy was technically feasible with favorable patient outcomes.
Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos , Esternotomia , Idoso , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Esternotomia/efeitos adversos , Toracotomia/métodos , Resultado do TratamentoRESUMO
BACKGROUND: The Firehawk stent (Shanghai MicroPort Medical Group, Shanghai, China), a novel biodegradable polymer sirolimus-eluting coronary stent has been evaluated in the randomized TARGET I trial in which low-risk patients were enrolled with strict eligibility criteria. Recently, the TARGET All Comers study has shown similar results of the Firehawk compared to the XIENCE stent (Abbott Vascular, Santa Clara). However, clinical outcomes in high-risk patients are unclear. METHODS: The TARGET All Comer study was a randomized trial that assigned patients to either Firehawk or XIENCE implantation. This TARGET AC subanalysis sought to evaluate the 2 year clinical outcomes of patients according to two risk groups; patients meeting all inclusion criteria and no exclusion criteria of the TARGET I trial were classified as "low-risk," while their counterparts were classified as "high-risk." The primary endpoint was target lesion failure. RESULTS: A total of 1,585 patients were included, of which 1,334 (84%) were classified as high-risk. At 2 years, the high-risk group had a significantly higher rate of TLF than the low-risk group (9.5% vs. 3.6%, p = .003), mainly driven by increased target vessel myocardial infarction (6.3% vs. 2.4%, p = .02). The Firehawk and XIENCE had no significant differences in TLF among both low-risk (3.1% vs. 4.2%, p = .66) and high-risk (9.9% vs. 9.1%, p = .57) patients. CONCLUSIONS: High-risk patients had worse clinical outcomes at 2 years in the TARGET All Comer study. Outcomes with the Firehawk were similar to the XIENCE stent among both low-risk and high-risk patients at 2 years.
Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: The FIREHAWK is a drug-eluting stent with a fully biodegradable sirolimus-containing polymer coating localised to recessed abluminal grooves on the stent surface. We investigated clinical outcomes with this targeted, low-dose, biodegradable polymer, sirolimus-eluting stent compared with XIENCE durable polymer, everolimus-eluting stents in an all-comers population. METHODS: The TARGET All Comers study was a prospective, multicentre, open-label randomised non-inferiority trial done at 21 centres in ten European countries. Patients with symptomatic or asymptomatic coronary artery disease and objective evidence of myocardial ischaemia who qualified for percutaneous coronary intervention were randomised 1:1 to undergo implantation of a FIREHAWK or XIENCE. Randomisation was web-based, with random block allocation and stratification by centre and ST elevation myocardial infarction. Outcome assessors were masked to treatment allocation, but treating physicians and patients were not. The primary endpoint was target lesion failure at 12 months, a composite of cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation. The control event rate for XIENCE was assumed to be 7%, the non-inferiority margin was 3.5%, and the primary analysis was in the intention-to-treat population, censoring patients who did not have either an event before 365 days or contact beyond 365 days. Late lumen loss was the primary endpoint of an angiographic substudy designed to investigate the non-inferiority of the FIREHAWK compared with the XIENCE stent. This trial is registered with ClinicalTrials.gov, number NCT02520180. FINDINGS: From Dec 17, 2015, to Oct 14, 2016, 1653 patients were randomly assigned to implantation of the FIREHAWK (n=823) or XIENCE (n=830). 65 patients in the FIREHAWK group and 66 in the XIENCE group had insufficient follow-up data and were excluded from the analyses. At 12 months, target lesion failure occurred in 46 (6·1%) of 758 patients in the FIREHAWK group and in 45 (5·9%) of 764 patients in the XIENCE group (difference 0·2%, 90% CI -1·9 to 2·2, pnon-inferiority=0·004, 95% CI -2·2 to 2·6, psuperiority=0·88). There were no differences in ischaemia-driven revascularisation or stent thrombosis rates at 12 months. 176 patients were included in the angiographic substudy, in which in-stent late lumen loss was 0·17 mm (SD 0·48) in the FIREHAWK group and 0·11 mm (0·52) in the XIENCE group (p=0·48), with an absolute difference of 0·05 mm (95% CI -0·09 to 0·18, pnon-inferiority=0·024). INTERPRETATION: In a broad all-comers population of patients requiring stent implantation for myocardial ischaemia, the FIREHAWK was non-inferior to the XIENCE as assessed with the primary endpoint of target lesion failure at 12 months and in-stent late lumen loss at 13 months. The FIREHAWK is a safe and effective alternative stent to treat patients with ischaemic coronary artery disease in clinical practice. FUNDING: Shanghai Microport Medical.
Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Imunossupressores/administração & dosagem , Isquemia Miocárdica/cirurgia , Sirolimo/administração & dosagem , Idoso , Estudos de Equivalência como Asunto , Everolimo/administração & dosagem , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Resultado do TratamentoRESUMO
BACKGROUND: Observational studies suggest there are gender based differences in the treatment of coronary artery disease, with women receiving evidence based therapy less frequently than suggested by current guidelines. The aim of our study was to evaluate gender based differences in the use of DES. METHODS: We analysed prospectively collected data from 100704 stent implantations in the PCI registry of the ALKK between 2005 and 2009. RESULTS: The usage of DES increased from 16.0 to 43.9%. Although women had smaller vessel sizes, they received DES less often compared to men (28.2 vs. 31.3%), with an adjusted odds ratio of 0.93 (95% confidence interval 0.89-0.97) at the age of 75, and an adjusted odds ratio of 0.89 (95% confidence interval 0.84-0.94) at the age of 80. CONCLUSION: Despite having smaller vessels than men, women were treated less often with DES. These findings apply to women above the age of 75 years. These findings support previous reports, that elderly women with coronary artery disease are treated differently to men.
Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Disparidades em Assistência à Saúde , Intervenção Coronária Percutânea/instrumentação , Avaliação de Processos em Cuidados de Saúde , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Alemanha , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: This study sought to compare the use and outcome of radial versus femoral access in patients treated with primary percutaneous coronary intervention (PCI) for acute ST elevation myocardial infarction (STEMI) in clinical practice. BACKGROUND: The radial approach for PCI in patients with STEMI has been suggested to have a lower rate of complications and bleeding and to improve prognosis compared with the femoral approach. However, there still is a large regional and national variation in its use. METHODS: Between 2008 and 2012 a total of 17,865 patients with STEMI without cardiogenic shock undergoing primary PCI were prospectively enrolled in the observational German PCI registry of the Arbeitsgemeinschaft leitende kardiologische Krankenhausärzte (ALKK). Transfemoral (TF) access was used in 15,270 (85.5%), transradial (TR) access in 2,530 (14.2%), and other access in 65 (0.3%) patients. In this analysis, 10,264 patients from 20 centers that had performed at least 5 TR-PCI for STEMI were included. This study compared TR-PCI (n = 2,454 23.9%) with TF-PCI (n = 7,810, 76.1%). RESULTS: Procedural success was high in both cohorts. Hospital mortality (1.8 vs. 5.1%, P < 0.001) and vascular access complications (0.3 vs. 1.8%, P < 0.001%) were lower in the TR group. In the multivariate analysis radial access was associated with an improved in-hospital survival rate (OR 0.47, 95% CI 0.35-0.65). CONCLUSIONS: The radial approach for PCI can be performed with excellent procedural success in selected STEMI patients and is associated with a lower rate of vascular access complications and hospital mortality.
Assuntos
Cateterismo Cardíaco/métodos , Eletrocardiografia , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/métodos , Idoso , Feminino , Artéria Femoral , Seguimentos , Alemanha/epidemiologia , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Artéria Radial , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico , Taxa de Sobrevida/tendências , Resultado do TratamentoRESUMO
BACKGROUND: In the REPAIR-AMI trial, intracoronary infusion of bone marrow-derived cells (BMCs) was associated with a significantly greater recovery of contractile function in patients with acute myocardial infarction (AMI) at 4-month follow-up than placebo infusion. The current analysis investigates clinical outcome and predictors of event-free survival at 5 years. METHODS AND RESULTS: In the multicentre, placebo-controlled, double-blind REPAIR-AMI trial, 204 patients received intracoronary infusion of BMCs (n = 101) or placebo (n = 103) into the infarct vessel 3-7 days following successful percutaneous coronary intervention. Fifteen patients died in the placebo group compared with seven patients in the BMC group (P = 0.08). Nine placebo-treated patients and five BMC-treated patients required rehospitalization for chronic heart failure (P = 0.23). The combined endpoint cardiac/cardiovascular/unknown death or rehospitalisation for heart failure was more frequent in the placebo compared with the BMC group (18 vs. 10 events; P = 0.10). Univariate predictors of adverse outcomes were age, the CADILLAC risk score, aldosterone antagonist and diuretic treatment, changes in left ventricular ejection fraction, left ventricular end-systolic volume, and N-terminal pro-Brain Natriuretic Peptide (all P < 0.01) at 4 months in the entire cohort and in the placebo group. In contrast, in the BMC group, only the basal (P = 0.02) and the stromal cell-derived factor-1-induced (P = 0.05) migratory capacity of the administered BMC were associated with improved clinical outcome. CONCLUSION: In patients of the REPAIR-AMI trial, established clinical parameters are associated with adverse outcome at 5 years exclusively in the placebo group, whereas the migratory capacity of the administered BMC determines event-free survival in the BMC-treated patients. These data disclose a potency-effect relationship between cell therapy and long-term outcome in patients with AMI.
Assuntos
Transplante de Medula Óssea/métodos , Monócitos/transplante , Infarto do Miocárdio/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Transplante de Medula Óssea/mortalidade , Intervalo Livre de Doença , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Infusões Intralesionais , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Readmissão do Paciente/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/mortalidade , Recidiva , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/terapia , Adulto JovemRESUMO
AIMS: The objective of the present analysis was to systematically examine the effect of intracoronary bone marrow cell (BMC) therapy on left ventricular (LV) function after ST-segment elevation myocardial infarction in various subgroups of patients by performing a collaborative meta-analysis of randomized controlled trials. METHODS AND RESULTS: We identified all randomized controlled trials comparing intracoronary BMC infusion as treatment for ST-segment elevation myocardial infarction. We contacted the principal investigator for each participating trial to provide summary data with regard to different pre-specified subgroups [age, diabetes mellitus, time from symptoms to percutaneous coronary intervention, infarct-related artery, LV end-diastolic volume index (EDVI), LV ejection fraction (EF), infarct size, presence of microvascular obstruction, timing of cell infusion, and injected cell number] and three different endpoints [change in LVEF, LVEDVI, and LV end-systolic volume index (ESVI)]. Data from 16 studies were combined including 1641 patients (984 cell therapy, 657 controls). The absolute improvement in LVEF was greater among BMC-treated patients compared with controls: [2.55% increase, 95% confidence interval (CI) 1.83-3.26, P < 0.001]. Cell therapy significantly reduced LVEDVI and LVESVI (-3.17 mL/m², 95% CI: -4.86 to -1.47, P < 0.001; -2.60 mL/m², 95% CI -3.84 to -1.35, P < 0.001, respectively). Treatment benefit in terms of LVEF improvement was more pronounced in younger patients (age <55, 3.38%, 95% CI: 2.36-4.39) compared with older patients (age ≥ 55 years, 1.77%, 95% CI: 0.80-2.74, P = 0.03). This heterogeneity in treatment effect was also observed with respect to the reduction in LVEDVI and LVESVI. Moreover, patients with baseline LVEF <40% derived more benefit from intracoronary BMC therapy. LVEF improvement was 5.30%, 95% CI: 4.27-6.33 in patients with LVEF <40% compared with 1.45%, 95% CI: 0.60 to 2.31 in LVEF ≥ 40%, P < 0.001. No clear interaction was observed between other subgroups and outcomes. CONCLUSION: Intracoronary BMC infusion is associated with improvement of LV function and remodelling in patients after ST-segment elevation myocardial infarction. Younger patients and patients with a more severely depressed LVEF at baseline derived most benefit from this adjunctive therapy.
Assuntos
Transplante de Medula Óssea/métodos , Infarto do Miocárdio/terapia , Adulto , Idoso , Volume Cardíaco/fisiologia , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda/fisiologiaRESUMO
OBJECTIVES: To evaluate the safety and effectiveness of the Kaname™ cobalt-chromium (Co-Cr), thin strut, bare metal stent (BMS) system for the treatment of coronary artery lesions. BACKGROUND: Despite widespread use of drug-eluting stents, a certain percentage of patients with coronary artery disease are still treated with BMS. Therefore, it is essential to evaluate their clinical performance. METHODS: Two hundred eighty-two patients were enrolled in this prospective, single-arm study including a predefined subset of 79 patients with small vessels. The primary end-point was freedom from target vessel failure (TVF) at 6 months. Key angiographic and intravascular ultrasound (IVUS) end-points were late loss, diameter stenosis, binary restenosis, and neointimal hyperplasia volume. RESULTS: Freedom from TVF at 6 months was 93.3% and at 1 year 90.8% in total population, and 92.4% and 87.3% in small vessels, respectively. Clinically driven target lesion revascularization (TLR) rates at 6 and 12 months were 4.3% and 6.4% in total population, and 3.8% and 7.6% in small vessels, respectively. At 6 months in-stent late loss was 0.75 ± 0.43 mm and binary restenosis rate was 16.9% in total population, and 0.64 ± 0.40 mm and 26.1% in small vessels, while IVUS assessed neointimal hyperplasia volume at 6 months was 128.9 ± 42.6 mm(3) for total population. There were no definite and probable stent thromboses up to 12 months. CONCLUSIONS: Results indicate good safety and effectiveness of the Kaname™ stent with clinically equivalent results in small and larger vessels, as such providing useful treatment option for patients with ischemic heart disease considered for BMS implantation.
Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Stents , Idoso , Cromo , Cobalto , Angiografia Coronária , Reestenose Coronária/epidemiologia , Feminino , França/epidemiologia , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Estudos ProspectivosRESUMO
Objective: A sternum-sparing approach of minimally invasive total coronary revascularization via left anterior thoracotomy demonstrated promising early outcomes in unselected patients with coronary artery multivessel disease. Follow-up data are still missing. Methods: From November 2019 to September 2023, coronary artery bypass grafting via left anterior minithoracotomy on cardiopulmonary bypass and cardioplegic cardiac arrest was performed as a routine procedure in 392 consecutive, nonemergency patients (345 men; 67.0 ± 9.9 years; range, 32-88 years). All patients had multivessel coronary artery disease (77.6% 3-vessel-disease, 22.4% 2-vessel-disease, and 32.9% left main stenosis). Patients at old age (older than a 80 years, 12.5%), with severe left ventricular dysfunction (ejection fraction <30%, 7.9%), diabetes mellitus (34.9%), massive obesity (body mass index > 35, 8.9%), and chronic lung disease (17.1%) were included. Mean European System for Cardiac Operative Risk Evaluation II score was 2.9 ± 2.8. Mean midterm follow-up (100%) was 15.2 ± 10.7 months (range, 0.1-39.5 months). Results: Left internal thoracic artery (99.0%), radial artery (70.4%), and saphenous vein grafts (57.4%) were used, and 70.4% of patients received at least 2 arterial grafts. A total of 3.0 ± 0.8 anastomoses (range, 2-5 anastomoses) per patient were performed to revascularize the territories of left anterior descending (98.7%), circumflex (91.6%), and right coronary (70.9%) artery. Complete anatomical revascularization was achieved in 95.1%. At follow-up, all-cause-mortality, myocardial infarction, repeat revascularization, and stroke was 3.1%, 1.5%, 5.4%, and 0.7%, respectively. Overall major adverse cardiac and cerebrovascular events rate was 8.7%. Conclusions: This is the first report of midterm follow-up after routine sternum-sparing total coronary revascularization via left anterior thoracotomy for multivessel coronary artery disease with a high rate of multiple arterial grafting and complete anatomical revascularization. Outcome was favorable and similar to that of contemporary conventional coronary artery bypass grafting.
RESUMO
BACKGROUND: EuroSCORE and completeness of revascularization predicts long-term survival after multivessel PCI (MV-PCI). The SYNTAX-Score has also been proposed to predict clinical outcome. The prognostic impact of these scores to predict long-term survival after PCI has not yet been compared. METHODS AND RESULTS: Long-term survival was assessed in 740 patients undergoing MV-PCI. We calculated EuroSCORE, SYNTAX-Score, STS-Score, the clinical SYNTAX-Score (CSS), and the "post-PCI residual SYNTAX-Score." Mean follow-up time was 4.5 ± 2.5 years. 341 patients (46%) were treated for ACS (STEMI N = 191; NSTEMI N = 150). 113 patients (15%) underwent PCI of left main coronary artery. The EuroSCORE was significantly lower for stable patients compared to patients with ACS (stable 4.1 ± 4.5, NSTEMI 13.9 ± 13.3, STEMI 18.1 ± 18.7, p < 0.001). The differences in the SYNTAX-Score were less obvious but even significant (stable 14.9 ± 8.6, NSTEMI 17.8 ± 9.9, STEMI 18.3 ± 9.0; p < 0.001). Patients in the highest tertiles of each risk score experienced a dramatically elevated mortality rate compared to the extremely low mortality rate in the lower tertiles (p log-rank <0.001). This comparison remained significant for the EuroSCORE and STS-Score but not for the SYNTAX-Score, when analysis was restricted to stable patients. The multivariate Cox-regression-analysis confirmed the logistic EuroSCORE, EuroSCORE II, and the STS-Score as independent predictors of long-term mortality, whereas the SYNTAX-Score (including residual form) and the CSS had no predictive value. CONCLUSION: The EuroSCORE and the STS-Score outperforms the SYNTAX-Score and the CSS in predicting long-term survival following MV-PCI. In addition, the residual SYNTAX-Score predicts long-term survival not independently.
Assuntos
Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Medição de Risco , Idoso , Angioplastia Coronária com Balão , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , StentsRESUMO
AIMS: We aimed to characterize the influence of acute myocardial infarction (AMI) on the metabolic activity of the bone marrow (BM) and on the composition and functional activity of BM-derived mononuclear cells (BMC). Acute ischaemia or other stressors induce the mobilization of progenitor cells from the BM stem cell niche. The effect of AMI on the numbers and functional activity of cells within the BM is unknown. METHODS AND RESULTS: In patients of the REPAIR-AMI trial as well as in mice, the number and functionality of BMC was compared with respect to the time interval from AMI. Activation of Wnt signalling was assessed after AMI induction in TOP-GAL transgenic reporter mice, carrying a ß-galactosidase gene driven by an LEF/TCF/ß-catenin responsive promoter. The metabolic activity of the BM, as determined by F-18-fluorodeoxyglucose-positron emission tomography, was significantly higher in patients with AMI compared with patients with chronic post-ischaemic heart failure. Moreover, the number of haematopoietic CD34(+) (P < 0.05) and CD133(+) (P < 0.05) cells in the BM aspirates was significantly increased in patients within 7 days after AMI. In order to confirm these clinical data, we induced AMI in mice, which time-dependently increased the number of c-kit + Sca-1 + lin- cells and colony-forming units in the BM. Activation of the BM by AMI induced a significant increase in Wnt signalling, which is known to induce proliferation of haematopoietic stem cells, and demonstrated increased levels of the Wnt target Axin-2 in BM-derived cells on Day 7 (P < 0.01 vs. control). CONCLUSION: Acute myocardial infarction is associated with an increased metabolic activity and increased levels of progenitor cells within days after AMI. These findings document an activation of the stem cell niche within the BM following AMI, which may have important implications for the optimal timing of cell aspirations used for therapeutic application in patients with AMI.
Assuntos
Medula Óssea/metabolismo , Células-Tronco Hematopoéticas/fisiologia , Monócitos/fisiologia , Infarto do Miocárdio/patologia , Transdução de Sinais/fisiologia , Proteína Wnt1/metabolismo , Adulto , Idoso , Animais , Proliferação de Células , Quimiocina CXCL12/farmacologia , Fatores Quimiotáticos/farmacologia , Quimiotaxia de Leucócito/fisiologia , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Infarto do Miocárdio/metabolismo , Compostos Radiofarmacêuticos , Ensaios Clínicos Controlados Aleatórios como Assunto , Proteína Wnt3A/farmacologiaRESUMO
Background: Transcatheter Aortic Valve Implantation (TAVI) has emerged over time, reflected in appropriate adjustments in the European Society of Cardiology (ESC) guidelines in 2007, 2012 and 2017. Objective: The aim of this study was to analyze in-hospital outcomes after TAVI in the development within a single heart center over a period of 10 years depending on adjustments in the guidelines, infrastructural and procedural determinants. Methods: 489 consecutive patients who underwent TAVI from 2010 and 2019 at our center were analyzed retrospectively. Patients were divided into 3 groups of different treatment circumstances depending on guidelines adjustments and local infrastructural progress (group 1: 2010-2015 (n = 132), group 2: 2016-2017 (n = 155), group 3: 2018-2019 (n = 202). The primary endpoint was defined as all-cause in-hospital mortality. Secondary endpoints were selected according to the Valve Academic Research Consortium (VARC)-2 definitions. Multivariate logistic regression analysis was performed to determine predictors of in-hospital mortality. Statistical significance was assumed for p < 0.05. Results: 489 patients (346 (70.8 %) transfemoral and 143 (29.2 %) transapical) underwent TAVI. Comparing periods (group 1 vs. 2 vs. 3) age (82.1 ± 6.2 vs. 82.5 ± 4.8 vs. 81.1 ± 5.1 years, p = 0.012) and EuroSCORE II (8.4 ± 6.0 vs. 5.8 ± 4.9 vs. 5.5 ± 5.0 %, p < 0.001) declined over time. Rates of in-hospital mortality decreased significantly (9.1 % vs. 5.8 % vs. 2.5 %, p = 0.029), especially with observed-to-expected mortality ratios indicating a disproportionate decline of in-hospital mortality (1.08 vs. 1.00 vs. 0.45). Furthermore, post-procedural complications, such as acute kidney injury stage 3 (10.6 % vs. 3.2 % vs. 4.5 %, p = 0.016) and bleeding complications (14.4 % vs. 11.6 % vs 7.9 %, p = 0.165) decreased from group 1 to 3. However, rates of permanent pacemaker implantations (7.6 % vs. 11.0 % vs. 22.8 %, p < 0.001) increased, associated with a switch towards self-expanding valves (0.0 % vs. 61.3 % vs. 76.7 %, p < 0.001). Length of hospitalization as well as stay at intensive care and intermediate care unit could be reduced significantly during the observation period. In multivariate analysis age (OR: 1.103; 95 % CI: 1.013 - 1.202; p = 0.025), creatinine level before TAVI (OR: 1.497; 95 % CI: 1.013 - 2.212; p = 0.043), atrial fibrillation (OR: 2.956; 95 % CI: 1.127 - 7.749; p = 0.028) and procedure duration (OR: 1.017; 95 % CI: 1.009 - 1.025; p < 0.001) could be identified as independent predictors of in-hospital mortality. Conclusion: This study identified age, creatinine level before TAVI, the presence of atrial fibrillation and procedure duration as independent predictors for in-hospital mortality. Although these predictors decreased during the observation period, the decline in hospital-mortality was disproportionate, which was indicated by an observed-to-expected mortality ratio of 0.45 for the last observation period. However, it can be assumed that apart from patient-related factors, there were further institutional, technical and procedural developments, which ran in parallel and affected in-hospital mortality rates after TAVI.
RESUMO
BACKGROUND: In the prospective, multicentre, randomised TARGET All Comers study, percutaneous coronary intervention (PCI) with the FIREHAWK biodegradable-polymer sirolimus-eluting stent (BP-SES) was non-inferior to the durable-polymer everolimus-eluting stent (DP-EES) for the primary endpoint of target lesion failure (TLF) at 12 months. AIMS: We aimed to report the final study outcomes at 5 years. METHODS: Patients referred for PCI were randomised to receive either a BP-SES or DP-EES in a 1:1 ratio in 10 European countries. Randomisation was stratified by centre and ST-elevation myocardial infarction (STEMI) presentation, and clinical follow-up extended to 5 years. The primary endpoint was TLF (composite of cardiac death, target vessel myocardial infarction [MI], or ischaemia-driven target lesion revascularisation). Secondary endpoints included patient-oriented composite events (POCE; composite of all-cause death, all MI, or any revascularisation and its components). RESULTS: From December 2015 to October 2016, 1,653 patients were randomly assigned to the BP-SES or DP-EES groups, of which 93.8% completed 5-year clinical follow-up or were deceased. At 5 years, TLF occurred in 17.1% of the BP-SES group and in 16.3% of the DP-EES group (p=0.68). POCE occurred in 34.0% of the BP-SES group and 32.7% of the DP-EES group (p=0.58). Revascularisation was the most common POCE, occurring in 19.3% of patients receiving BP-SES and 19.2% receiving DP-EES, of which less than one-third was ischaemia-driven target lesion-related. In the landmark analysis, there were no differences in the rates of TLF and POCE between groups from 1 to 5 years, and these results were consistent across all subgroups. CONCLUSIONS: In an all-comers population requiring stent implantation for myocardial ischaemia, the BP-SES was non-inferior to the DP-EES for the primary endpoint of TLF at 12 months, and results were sustained at 5 years, confirming the long-term safety and efficacy of the FIREHAWK BP-SES.
Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis , Everolimo , Infarto do Miocárdio/etiologia , PolímerosRESUMO
BACKGROUND: Transcatheter aortic valve implantation (TAVI) has emerged as a new therapeutic option in high-risk patients with severe aortic stenosis. AIMS: PARTNER EU is the first study to evaluate prospectively the procedural and mid-term outcomes of transfemoral (TF) or transapical (TA) implantation of the Edwards SAPIEN® valve involving a multi-disciplinary approach. METHODS AND RESULTS: Primary safety endpoints were 30 days and 6 months mortality. Primary efficacy endpoints were haemodynamic and functional improvement at 12 months. One hundred and thirty patients (61 TF, 69 TA), aged 82.1 ± 5.5 years were included. TA patients had higher logistic EuroSCORE (33.8 vs. 25.7%, P = 0.0005) and more peripheral disease (49.3 vs. 16.4%, P< 0.0001). Procedures were aborted in four TA (5.8%) and six TF cases (9.8%). Valve implantation was successful in the remaining patients in 95.4 and 96.4%, respectively. Thirty days and 6 months survival were 81.2 and 58.0% (TA) and 91.8 and 90.2% (TF). In both groups, mean aortic gradient decreased from 46.9 ± 18.1 to 10.9 ± 5.4 mmHg 6 months post-TAVI. In total, 78.1 and 84.8% of patients experienced significant improvement in New York Heart Association (NYHA) class, whereas 73.9 and 72.7% had improved Kansas City Cardiomyopathy Questionnaire (KCCQ) scores in TA and TF cohorts, respectively. CONCLUSION: This first team-based multi-centre European TAVI registry shows promising results in high-risk patients treated by TF or TA delivery. Survival rates differ significantly between TF and TA groups and probably reflect the higher risk profile of the TA cohort. Optimal patient screening, approach selection, and device refinement may improve outcomes.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/mortalidade , Causas de Morte , Ecocardiografia , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Resultado do TratamentoRESUMO
BACKGROUND: The transradial approach for coronary procedures is associated with a low complication rate, but specific training is considered mandatory. METHODS: Procedural characteristics (contrast dye: CD; fluoroscopy time: FT, patient radiation dose: RD) and local complication rates were prospectively assessed in 784 consecutive patients who underwent transradial coronary procedures. The study was divided into an implementation (2008-IP) and an evaluation period (2009-EP). Transradial (N = 624) and transfemoral (N = 842) procedural characteristics were compared in the EP. RESULTS: The amount of CD (mL) of transradial coronary angiography was similar between IP (75 [IQR 60-100]) and EP (70 [55-100]; P = 0.630). In contrast, FT (min) of transradial coronary angiography could be reduced from IP (4.4 [3.2-6.8]) to EP (4.1 [2.7-6.5]; P = 0.036), whereas RD (µGy * qcm) was similar (IP: 1623 [1042-3026]); EP (1576 [944-2530]; P = 0.149). Safety data showed a low complication rate: 0.2% access failure, 0.1% dissection, 0.7% vessel closure. Transfemoral procedures were followed by significantly more procedure- related transfusions (1.3% vs. 0%; P = 0.003). The comparison between transfemoral and transradial procedures demonstrated prolonged FT for transradial procedures (transfemoral 2.9 [1.7-5.5]; transradial 4.1 [2.7-6.5]; P = 0.002), whereas CD was similar (transfemoral 70 [55-100]; transradial 70 [55-100]; P = 0.248). The prolonged FT was restricted to coronary angiography but did not differ for PCI (transfemoral 9.7 [5.8-18.1]; transradial 8.9 [5.3-16.5]; P = 0.433). CONCLUSION: A transradial program can be implemented with safety; therefore, the transradial approach should be preferred in suitable patients. Since spasm occurrence was the major determinant of procedural failure, further effort is need to develop better strategies for spasm prevention.
Assuntos
Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/radioterapia , Vasos Coronários/efeitos da radiação , Doses de Radiação , Idoso , Doença da Artéria Coronariana/diagnóstico , Segurança de Equipamentos , Feminino , Fluoroscopia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatística como Assunto , Fatores de TempoRESUMO
AIMS: During the COVID-19 pandemic, hospital admissions for cardiac care have declined. However, effects on mortality are unclear. Thus, we sought to evaluate the impact of the lockdown period in central Germany on overall and cardiovascular deaths. Simultaneously we looked at catheterization activities in the same region. METHODS AND RESULTS: Data from 22 of 24 public health-authorities in central Germany were aggregated during the pandemic related lockdown period and compared to the same time period in 2019. Information on the total number of deaths and causes of death, including cardiovascular mortality, were collected. Additionally, we compared rates of hospitalization (n = 5178) for chronic coronary syndrome (CCS), acute coronary syndrome (ACS), and out of hospital cardiac arrest (OHCA) in 26 hospitals in this area. Data on 5,984 deaths occurring between March 23, 2020 and April 26, 2020 were evaluated. In comparison to the reference non-pandemic period in 2019 (deaths: n = 5832), there was a non-significant increase in all-cause mortality of 2.6% [incidence rate ratio (IRR) 1.03, 95% confidence interval (CI) 0.99-1.06; p = 0.16]. Cardiovascular and cardiac mortality increased significantly by 7.6% (IRR 1.08, 95%-CI 1.01-1.14; p = 0.02) and by 11.8% (IRR 1.12, 95%-CI 1.05-1.19; p < 0.001), respectively. During the same period, our data revealed a drop in cardiac catherization procedures. CONCLUSION: During the COVID-19-related lockdown a significant increase in cardiovascular mortality was observed in central Germany, whereas catherization activities were reduced. The mechanisms underlying both of these observations should be investigated further in order to better understand the effects of a pandemic-related lockdown and social-distancing restrictions on cardiovascular care and mortality.
Assuntos
COVID-19 , Cateterismo Cardíaco/tendências , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/terapia , Hospitalização/tendências , Intervenção Coronária Percutânea/tendências , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Doenças Cardiovasculares/diagnóstico , Causas de Morte/tendências , Feminino , Alemanha , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Fatores de Risco , Fatores de TempoRESUMO
BACKGROUND: The prognostic relevance of complete revascularization (CR) in patients with multivessel coronary artery disease (MV-CAD) has been established so far for surgical treatment strategies rather than for percutaneous coronary revascularization (PCI). In addition, different definitions of CR have further complicated the interpretation of clinical studies. METHODS: Procedural characteristics and long-term overall survival were assessed in 679 consecutive "all-comer" patients, who underwent PCI in at least two main vessels. We adapted three definitions of CR from the coronary artery bypass grafting (CABG) trials. CR was achieved if following MV-PCI one of the three criteria was met: (1) no residual stenosis in a main coronary vessel, (2) no residual stenosis in any coronary segment, or (3) no residual stenosis in the left anterior descending (LAD) and at least one further main branch. The main objective was the evaluation of predictors of incomplete revascularization and the prognostic impact of CR in MV-PCI patients. RESULTS: CR was achieved in 76%, 67%, and 95%, respectively, (definitions 1-3). Patients without CR were older, had a lower ejection fraction, and presented more often with acute coronary syndromes (ACS). Clinical long-term follow-up regarding survival was available in 664 patients (98%) with a mean follow-up of 2.5 +/- 1.6 years. Independent of the specific definition, CR was associated with a reduced long-term mortality by approximately 50%. After adjusting for relevant baseline parameters, only absence of residual stenosis in all coronary segments remained as an independent predictor of long-term prognosis (hazard ratio [HR]= 0.51, 95% confidence interval [CI]: 0.28-0.93; P = 0.025). CONCLUSIONS: CR of all coronary segments is associated with improved overall survival after MV-PCI.