Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Health Serv Res ; 23(1): 1313, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017443

RESUMO

BACKGROUND: Due to the growing economic pressure, there is an increasing interest in the optimization of operational processes within surgical operating rooms (ORs). Surgical departments are frequently dealing with limited resources, complex processes with unexpected events as well as constantly changing conditions. In order to use available resources efficiently, existing workflows and processes have to be analyzed and optimized continuously. Structural and procedural changes without prior data-driven analyses may impair the performance of the OR team and the overall efficiency of the department. The aim of this study is to develop an adaptable software toolset for surgical workflow analysis and perioperative process optimization in arthroscopic surgery. METHODS: In this study, the perioperative processes of arthroscopic interventions have been recorded and analyzed subsequently. A total of 53 arthroscopic operations were recorded at a maximum care university hospital (UH) and 66 arthroscopic operations were acquired at a special outpatient clinic (OC). The recording includes regular perioperative processes (i.a. patient positioning, skin incision, application of wound dressing) and disruptive influences on these processes (e.g. telephone calls, missing or defective instruments, etc.). For this purpose, a software tool was developed ('s.w.an Suite Arthroscopic toolset'). Based on the data obtained, the processes of the maximum care provider and the special outpatient clinic have been analyzed in terms of performance measures (e.g. Closure-To-Incision-Time), efficiency (e.g. activity duration, OR resource utilization) as well as intra-process disturbances and then compared to one another. RESULTS: Despite many similar processes, the results revealed considerable differences in performance indices. The OC required significantly less time than UH for surgical preoperative (UH: 30:47 min, OC: 26:01 min) and postoperative phase (UH: 15:04 min, OC: 9:56 min) as well as changeover time (UH: 32:33 min, OC: 6:02 min). In addition, these phases result in the Closure-to-Incision-Time, which lasted longer at the UH (UH: 80:01 min, OC: 41:12 min). CONCLUSION: The perioperative process organization, team collaboration, and the avoidance of disruptive factors had a considerable influence on the progress of the surgeries. Furthermore, differences in terms of staffing and spatial capacities could be identified. Based on the acquired process data (such as the duration for different surgical steps or the number of interfering events) and the comparison of different arthroscopic departments, approaches for perioperative process optimization to decrease the time of work steps and reduce disruptive influences were identified.


Assuntos
Artroscopia , Salas Cirúrgicas , Humanos , Fluxo de Trabalho , Hospitais Universitários
2.
Langenbecks Arch Surg ; 407(8): 3755-3762, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36070032

RESUMO

PURPOSE: Since their invention 40 years ago, totally implantable venous-access ports (TIVAPs) have become indispensable in cancer treatment. The aim of our study was to analyze complications under standardized operative and perioperative procedures and to identify risk factors for premature port catheter explantation. METHODS: A total of 1008 consecutive TIVAP implantations were studied for success rate, perioperative, early, and late complications. Surgical, clinical, and demographic factors were analyzed as potential risk factors for emergency port catheter explantation. RESULTS: Successful surgical TIVAP implantation was achieved in 1005/1008 (99.7%) cases. No intraoperative or perioperative complications occurred. A total of 32 early complications and 88 late complications were observed leading to explantation in 11/32 (34.4%) and 34/88 (38.6%) cases, respectively. The most common complications were infections in 4.7% followed by thrombosis in 3.6%. Parameters that correlated with unplanned TIVAP explantation were gender (port in situ: female 95% vs. male 91%, p = 0.01), underlying disease (breast cancer 97% vs. gastrointestinal 89%, p = 0.004), indication (chemotherapy 95% vs. combination of chemotherapy and parenteral nutrition 64%, p < 0.0001), and type of complication (infection 13.4% vs. TIVAP-related complication 54% and thrombosis 95%, p < 0.0001). CONCLUSION: Standardized operative and perioperative TIVAP implantation procedures provide excellent results and low explantation rate.


Assuntos
Cateterismo Venoso Central , Trombose , Masculino , Feminino , Humanos , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Cateteres de Demora/efeitos adversos , Remoção de Dispositivo , Fatores de Risco , Estudos Retrospectivos
3.
Minim Invasive Ther Allied Technol ; 31(8): 1131-1139, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36260701

RESUMO

INTRODUCTION: A novel multipurpose bipolar radiofrequency instrument, the Erbe Dissector (EDS), which simultaneously seals and cuts tissue, was developed. Ex vivo sealing rate and time, burst pressure, jaw temperature and thermal spread were studied in porcine renal arteries. MATERIAL AND METHODS: In vivo, 13 surgical tasks were performed in two pigs: beside sealing rate and time, overall performance in sharp and blunt dissection, tissue sticking, hemostasis, precision, etc., were evaluated by four surgeons compared with ENSEAL G2 (EG2) using surveys on a Likert scale (1 = very poor; 5 = very good). RESULTS: Ex vivo, the EDS sealing rate was 91.7% (33/36 arteries) at an average sealing time of 2.1 s (range 1.7-2.8) and a burst pressure of 1040 ± 350 mmHg. The maximum jaw temperature was 87 ± 4 °C and the mean lateral thermal spread was 0.8 ± 0.2 mm. In vivo, the sealing rate for arteries and veins was 92.6% (50/54) and the median seal and cut time was 1.6 s (range: 1.3-2.9). The average EDS performance score across all tasks was 4.4 ± 0.6 Likert points. For five shared tasks, EDS was better than EG2 (4.4 ± 0.5 versus 3.4 ± 0.6 Likert points; p = 0.016). CONCLUSIONS: EDS seals and cuts arteries and veins rapidly with good safety and user-friendliness.


Assuntos
Hemostasia Cirúrgica , Artéria Renal , Suínos , Animais , Artéria Renal/cirurgia , Veias/cirurgia , Ligadura , Eletrocoagulação
4.
BMC Surg ; 19(1): 160, 2019 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-31690302

RESUMO

BACKGROUND: Electrosurgical vessel sealers are gradually replacing conventional techniques such as ligation and clipping. Algorithms that control electrosurgical units (ESU), known as modes, are important for applications in different surgical disciplines. This chronic porcine animal study aimed to evaluate the safety and effectiveness of the novel thermoSEAL electrosurgical vessel sealing mode (TSM). The BiClamp® mode (BCM) of the renowned VIO® 300 D ESU served as control. BCM has been widely available since 2002 and has since been successfully used in many surgical disciplines. The TSM, for the novel VIO® 3 ESU, was developed to reduce sealing time and/or thermal lateral spread adjacent to the seal while maintaining clinical success rates. The primary aim of this study was to investigate the long-term and intraoperative seal quality of TSM. METHODS: The BiCision® device was used for vessel sealing with TSM and BCM in ten German Landrace pigs which underwent splenectomy and unilateral nephrectomy during the first intervention of the study. The seals were cut with the BiCision® knife. Ninety-nine arteries, veins and vascular bundles were chronically sealed for 5 or 21 days. Thereafter, during the second and terminal intervention of the study, 97 additional arteries and veins were sealed. The carotid arteries were used for histological evaluation of thermal spread. RESULTS: After each survival period, no long-term complications occurred with either mode. The intraoperative seal failure rates, i.e. vessel leaking or residual blood flow after the first sealing activation, were 2% with TSM versus 6% with BCM (p = 0.28). The sealing time was significantly shorter with TSM (3.5 ± 0.69 s vs. 7.3 ± 1.3 s, p < 0.0001). The thermal spread and burst pressure of arteries sealed with both modes were similar (p = 0.18 and p = 0.61) and corresponded to the histological evaluation. The measured tissue sticking parameter was rare with both modes (p = 0.33). Tissue charring did not occur. Regarding the cut quality, 97% of the seals were severed in the first and 3% in the second attempt (both with TSM and BCM). CONCLUSIONS: The novel TSM seals blood vessels twice as fast as the BCM while maintaining excellent tissue effect and clinical success rates. TRIAL REGISTRATION: Not applicable.


Assuntos
Algoritmos , Eletrocirurgia , Nefrectomia , Esplenectomia , Animais , Feminino , Artérias/cirurgia , Eletrocoagulação , Eletrocirurgia/métodos , Ligadura , Nefrectomia/métodos , Esplenectomia/métodos , Suínos , Veias , Distribuição Aleatória
5.
Surg Endosc ; 32(3): 1456-1463, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28924734

RESUMO

BACKGROUND: Bipolar vessel sealing has been successfully introduced in a variety of procedures like prostatectomy, hysterectomy, and nephrectomy. In this study, we evaluated a new sealing mode-the thermoSEAL® mode (TSM)-operated with the VIO3 generator in an ex vivo and in vivo animal study and compared the results with the commercially available BiClamp mode (BCM), operated with the VIO300D generator. Two different instruments were used in combination with both modes, BiCision® and BiClamp® 201T (Erbe Elektromedizin GmbH). METHODS: In the ex vivo experiment, the sealing of renal arteries was evaluated using both instruments and modes. For the in vivo study, different types of arteries and veins were sealed using both modes and instruments in a side-by-side comparison for acute complications in a total of four animals. RESULTS: Mean burst pressure was in all cases significantly above 360 mmHg (p < 0.001). Sealing time during the ex vivo setting was significantly shorter for TSM compared to BCM: BiCision® (3.7 ± 0.4 vs. 7.1 ± 0.3 s; p < 0.0001); BiClamp® 201T (3.9 ± 0.3 vs. 5.1 ± 1.1 s; p < 0.0015). Lateral thermal damage was more pronounced for BCM: BiCision® (TSM 1.4 ± 0.3 mm vs. BCM 1.9 ± 0.2 mm; p < 0.0001); BiClamp® 201T (TSM 1.9 ± 0.6 mm vs. BCM 3.1 ± 0.6 mm; p < 0.0001). The sealing time during the in vivo study was significantly shorter for TSM in combination with BiCision® for arteries [TSM 3.0 ± 0.7 s vs. BCM 6.5 ± 1.3 s, (p < 0.0001) and veins 3.2 ± 1.1 vs. 5.8 ± 1.8 s, (p < 0.0001)]. No significant differences were seen for the two modes used with BiClamp® 201T [artery: TSM 3.3 ± 0.7 s vs. BCM 3.4 ± 0.9 s, (p = 0.891)]. High sealing rates for arteries (100%) and veins (>90%) were noted for both instruments and modes. CONCLUSIONS: While both modes used with two different instruments reveal high safety characterized by a high burst pressure, low thermal damage (ex vivo) zones, and high sealing rates (in vivo), the thermoSEAL® mode convinces by its fast sealing speed probably helping to reduce operation time.


Assuntos
Artérias Carótidas/cirurgia , Eletrocirurgia/instrumentação , Hemostasia Cirúrgica/instrumentação , Artéria Renal/cirurgia , Veias/cirurgia , Animais , Eletrocirurgia/efeitos adversos , Eletrocirurgia/métodos , Hemostasia Cirúrgica/efeitos adversos , Hemostasia Cirúrgica/métodos , Técnicas In Vitro , Modelos Animais , Duração da Cirurgia , Estudos Prospectivos , Distribuição Aleatória , Suínos
6.
BMC Anesthesiol ; 18(1): 80, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29969995

RESUMO

BACKGROUND: Management of a patient's body temperature is an important aspect of care that should be addressed by targeted temperature management (TTM). Often, non-invasive methods like forced-air blankets are used. Especially in the operating room this management may be a subsidiary and repetitive task requiring constant observation of the patient's body temperature and adaption using the limited set of available settings. Thus, automation of TTM is a feasible target to improve patient outcome and reduce caregiver workload. METHODS: A Philips IntelliVue MP 50 patient monitor with an arterial PiCCO catheter system was used to measure patient blood temperature. Thermal management was performed with a 3M Bair Hugger 755 warming unit with forced air blankets. The warming unit was extended by a computer interface to allow for remote and automated control. A proposed closed-loop algorithm reads the measured temperature and performs automated control of the 3M Bair Hugger. Evaluation was performed in an experimental intensive care setting for animal studies. Two fully automated trials are compared with two manual and two uncontrolled trials in the same study setting using six female pigs for prolonged observation times of up to 90 hours in each trial. RESULTS: The developed system and proposed algorithm allow more precise temperature management by keeping a set target temperature within a range of ± 0.5 °C in 88% of the observation time and within a range of ± 1.0 °C at all times. The proposed algorithm yielded better performance than did manual control or uncontrolled trials. It was able to adapt to individual patient needs as it is more dynamic than look-up table approaches with fixed settings for various temperatures. CONCLUSIONS: Closed-loop TTM using non-invasive forced-air warming blankets was successfully tested in a porcine study with the proposed hardware interface and control algorithm. This automation can be beneficial for patient outcome and can reduce caregiver workload and patient risk in clinical settings. As temperature readings are most often available, existing devices like the 3M Bair Hugger can easily be expanded. However, even if clinical application is feasible, open questions regarding approval and certification of such automated systems within the current legal situation still need to be answered.


Assuntos
Automação/métodos , Roupas de Cama, Mesa e Banho , Temperatura Corporal , Algoritmos , Animais , Estudos de Viabilidade , Feminino , Suínos
7.
J Vasc Interv Radiol ; 26(11): 1728-34.e1-3, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26233838

RESUMO

PURPOSE: To evaluate the distribution of superparamagnetic iron oxide (SPIO)-labeled cells in a perfused segment of a porcine artery and to estimate the number of adherent cells by means of magnetic resonance (MR) imaging. MATERIALS AND METHODS: Six vessel specimens (diameters between 0.8 and 1.2 cm) were placed in a bioreactor system, and 2 × 10(4) to 1 × 10(6) SPIO-labeled endothelial colony-forming cells were injected into the artery within the perfused reactor. The area of resulting signal extinctions at the inner wall of the vessels was quantified on MR images by using a high-resolution T2*-weighted sequence with a slice-by-slice approach. After imaging, the labeled cells were quantified histologically. RESULTS: The total iron load of each cell was 56.5 pg ± 14.4. In the applied range of 2 × 10(4) to 1 × 10(6) cells per vessel, the area of iron-induced signal extinction at the vessel wall on T2*-weighted imaging corresponded to the histologically detected cell number (r = 0.98, P < .001). CONCLUSIONS: A correlation between the area of signal extinction and the number of labeled cells at the vessel wall was found. This might help to evaluate dose rates in further clinical applications of intravascular cell-based therapies.


Assuntos
Adesão Celular/fisiologia , Rastreamento de Células/métodos , Dextranos , Imagem por Ressonância Magnética Intervencionista/métodos , Nanopartículas de Magnetita , Artérias Torácicas/citologia , Artérias Torácicas/fisiologia , Animais , Células Cultivadas , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem , Estatística como Assunto , Transplante de Células-Tronco/métodos , Células-Tronco , Suínos , Artérias Torácicas/cirurgia
8.
Eur J Radiol ; 171: 111267, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38169217

RESUMO

PURPOSE: Computed tomography (CT) scans are a significant source of medically induced radiation exposure. Novel deep learning-based denoising (DLD) algorithms have been shown to enable diagnostic image quality at lower radiation doses than iterative reconstruction (IR) methods. However, most comparative studies employ low-dose simulations due to ethical constraints. We used real intraindividual animal scans to investigate the dose-reduction capabilities of a DLD algorithm in comparison to IR. MATERIALS AND METHODS: Fourteen veterinarian-sedated alive pigs underwent 2 CT scans on the same 3rd generation dual-source scanner with two months between each scan. Four additional scans ensued each time, with mAs reduced to 50 %, 25 %, 10 %, and 5 %. All scans were reconstructed ADMIRE levels 2 (IR2) and a novel DLD algorithm, resulting in 280 datasets. Objective image quality (CT numbers stability, noise, and contrast-to-noise ratio) was measured via consistent regions of interest. Three radiologists independently rated all possible dataset combinations per time point for subjective image quality (-1 = inferior, 0 = equal, 1 = superior). The points were averaged for a semiquantitative score, and inter-rater agreement was measured using Spearman's correlation coefficient and adequately corrected mixed-effects modeling analyzed objective and subjective image quality. RESULTS: Neither dose-reduction nor reconstruction method negatively impacted CT number stability (p > 0.999). In objective image quality assessment, the lowest radiation dose achievable by DLD when comparing noise (p = 0.544) and CNR (p = 0.115) to 100 % IR2 was 25 %. Overall, inter-rater agreement of the subjective image quality ratings was strong (r ≥ 0.69, mean 0.93 ± 0.05, 95 % CI 0.92-0.94; each p < 0.001), and subjective assessments corroborated that DLD at 25 % radiation dose was comparable to 100 % IR2 in image quality, sharpness, and contrast (p ≥ 0.281). CONCLUSIONS: The DLD algorithm can achieve image quality comparable to the standard IR method but with a significant dose reduction of up to 75%. This suggests a promising avenue for lowering patient radiation exposure without sacrificing diagnostic quality.


Assuntos
Aprendizado Profundo , Humanos , Animais , Suínos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Modelos Animais
9.
Cancers (Basel) ; 16(3)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38339389

RESUMO

BACKGROUND: Obtaining large amounts of real patient data involves great efforts and expenses, and processing this data is fraught with data protection concerns. Consequently, data sharing might not always be possible, particularly when large, open science datasets are needed, as for AI development. For such purposes, the generation of realistic synthetic data may be the solution. Our project aimed to generate realistic cancer data with the use case of laryngeal cancer. METHODS: We used the open-source software Synthea and programmed an additional module for development, treatment and follow-up for laryngeal cancer by using external, real-world (RW) evidence from guidelines and cancer registries from Germany. To generate an incidence-based cohort view, we randomly drew laryngeal cancer cases from the simulated population and deceased persons, stratified by the real-world age and sex distributions at diagnosis. RESULTS: A module with age- and stage-specific treatment and prognosis for laryngeal cancer was successfully implemented. The synthesized population reflects RW prevalence well, extracting a cohort of 50,000 laryngeal cancer patients. Descriptive data on stage-specific and 5-year overall survival were in accordance with published data. CONCLUSIONS: We developed a large cohort of realistic synthetic laryngeal cancer cases with Synthea. Such data can be shared and published open source without data protection issues.

10.
Eur J Clin Invest ; 43(1): 11-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23078202

RESUMO

BACKGROUND: With increasing improvements of patient survival after liver transplantation, the focus on outcome measures shifts from survival rate to quality of life. Individual quality of life is crucial to rehabilitate patients after transplantation. Therefore, it is important to identify specific issues that contribute to high individual quality of life. In contrast to the Short form 36 Health Survey (SF-36), the Schedule for the Evaluation of Individual aspects of Quality of Life-direct weighting (SEIQoL-DW) allows patients to name the areas of life, which are important to them. DESIGN: In a semi-structured interview style, 71 patients following liver transplant were asked to complete the SEIQoL-DW and the SF-36 in a cross-sectional design. RESULTS: We found five quality of life areas that were chosen by more than half of the patients: family, friends, sports, partnership and profession/occupation. Health was only mentioned by 45% of all patients. Individual quality of life did not differ from healthy population. In the SF-36, patients showed normal mental health parameters but reduced physical components. A strong correlation between SEIQoL-DW-Index and the mental component summary of the SF-36 was observed. CONCLUSION: In addition to the widely used standardized SF-36, the individual measure SEIQoL-DW shows new aspects concerning the areas of quality of life, which are personally important to the participants. Less than half of our patients mentioned health and the five most nominated areas are not related to health. By focusing on health, the importance of health-related factors is overrated, and the impact of non-medical effects is underrepresented.


Assuntos
Transplante de Fígado/psicologia , Ocupações , Qualidade de Vida , Apoio Social , Adulto , Estudos de Casos e Controles , Estudos Transversais , Seguimentos , Alemanha , Humanos , Pessoa de Meia-Idade , Análise Multivariada , Inquéritos e Questionários
11.
Diagnostics (Basel) ; 13(21)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37958243

RESUMO

Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60-65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife® flex T-Type (HK-T) and the Olympus DualKnife® J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified.

12.
Acad Radiol ; 30(8): 1678-1694, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36669998

RESUMO

OBJECTIVES: CT low-dose simulation methods have gained significant traction in protocol development, as they lack the risk of increased patient exposure. However, in-vivo validations of low-dose simulations are as uncommon as prospective low-dose image acquisition itself. Therefore, we investigated the extent to which simulated low-dose CT datasets resemble their real-dose counterparts. MATERIALS AND METHODS: Fourteen veterinarian-sedated alive pigs underwent three CT scans on the same third generation dual-source scanner with 2 months between each scan. At each time, three additional scans ensued, with mAs reduced to 50%, 25%, and 10%. All scans were reconstructed using wFBP and ADMIRE levels 1-5. Matching low-dose datasets were generated from the 100% scans using reconstruction-based and DICOM-based simulations. Objective image quality (CT numbers stability, noise, and signal-to-noise ratio) was measured via consistent regions of interest. Three radiologists independently rated all possible dataset combinations per time point for subjective image quality (-1=inferior, 0=equal, 1=superior). The points were averaged for a semiquantitative score, and inter-rater-agreement was measured using Spearman's correlation coefficient. A structural similarity index (SSIM) analyzed the voxel-wise similarity of the volumes. Adequately corrected mixed-effects analysis compared objective and subjective image quality. Multiple linear regression with three-way interactions measured the contribution of dose, reconstruction mode, simulation method, and rater to subjective image quality. RESULTS: There were no significant differences between objective and subjective image quality of reconstruction-based and DICOM-based simulation on all dose levels (p≥0.137). However, both simulation methods produced significantly lower objective image quality than real-dose images below 25% mAs due to noise overestimation (p<0.001; SSIM≤89±3). Overall, inter-rater-agreement was strong (r≥0.68, mean 0.93±0.05, 95% CI 0.92-0.94; each p<0.001). In regression analysis, significant decreases in subjective image quality were observed for lower radiation doses (b ≤ -0.387, 95%CI -0.399 to -0.358; p<0.001) but not for reconstruction modes, simulation methods, raters, or three-way interactions (p≥0.103). CONCLUSION: Simulated low-dose CT datasets are subjectively and objectively indistinguishable from their real-dose counterparts down to 25% mAs, making them an invaluable tool for efficient low-dose protocol development.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Animais , Suínos , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos
13.
Acta Neurochir Suppl ; 114: 169-72, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22327686

RESUMO

BACKGROUND: Only a few experimental reports are available on the direct comparison of Licox(®) and Raumedic(®)-Neurovent-PTO brain tissue oxygen pressure (P(br)O(2)) monitors. We compared the two systems regarding their measurement properties under experimental in vitro and in vivo conditions. MATERIALS AND METHODS: Eight Licox(®) and Raumedic(®) Neurovent-PTO(®) sensors were tested for 10 min at 37°C, atmospheric pressure, at an oxygen content of 0% and 100% before and after the in vivo test. The same probes were implanted in German landrace pigs, which underwent hepatectomy. The mean P(br)O(2) values were recorded every minute. An O(2) challenge with inhalation of 100% O(2) for 10 min was performed 2 h post-abdominal surgery. RESULTS: At 0% O(2) content values varied from 0.2 to 7 mmHg, at 100% O(2) content from 130 to 165 mmHg. No difference between probes was found. In vivo tests: Raumedic® showed higher P(br)O(2) values (mean +6.3 mmHg, p < 0.0001) compared with Licox®. During O(2) challenge, both probes responded similarly; however, Raumedic(®) had a 10% higher response amplitude (p < 0.005). After explantation there was again no difference between the two sensors. CONCLUSION: Raumedic(®) sensors measured higher P(br)O(2) values. There was no significant difference regarding overall measurement of in vitro accuracy between the two probes, which proved to be robust when used consecutively for longer periods and in different environments.


Assuntos
Encéfalo/metabolismo , Técnicas Eletroquímicas/instrumentação , Oxigênio/análise , Processamento de Sinais Assistido por Computador/instrumentação , Algoritmos , Análise de Variância , Animais , Jejum , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Oxigênio/metabolismo , Suínos
14.
Acta Neurochir Suppl ; 114: 173-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22327687

RESUMO

OBJECTIVE: To evaluate if ORx is dependent on the type of brain tissue O(2) (P(br)O(2)) probe in an in vivo setting. METHODS: In eight German landrace pigs two types of probes were implanted simultaneously in the same cerebral hemisphere. All pigs underwent hepatectomy and received neuromonitoring until death. A LICOX(®) probe CCI.S, representing a Clarke type electrode, was compared with a Raumedic Neurovent PTO, representing an optode. Data were sampled at 50 Hz. Average values were calculated every 30 s. Cerebral perfusion pressure (CPP) was averaged over 30 s. ORx was calculated for each probe. To increase the signal to noise ratio of the ORx, the ORx values, which had been assessed every minute, were averaged over 1 h. RESULTS: The overall measurement time was 145.1 h (8,703 data pairs). Despite a mean difference of 6.2 mmHg (p < 0.0001) in the measured values of P(br)O(2), the mean ORx(licox) was 0.139, mean ORx(raumedic) 0.146 (p = 0.2098). Correlation coefficient of ORx values assessed every minute and every hour was 0.52 and 0.58 respectively. CONCLUSION: Despite this significant difference in absolute values of P(br)O(2) the derived mean ORx values were not different. Similar to the established Licox system, the Raumedic system seems to enable a valid ORx recording.


Assuntos
Córtex Cerebral/fisiologia , Pressão Intracraniana/fisiologia , Oximetria/instrumentação , Oxigênio/análise , Animais , Pressão Sanguínea/fisiologia , Modelos Animais , Oximetria/métodos , Oxigênio/metabolismo , Pressão Parcial , Estatísticas não Paramétricas , Suínos
15.
Acta Neurochir Suppl ; 114: 387-91, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22327729

RESUMO

Volume loading is a common method used to ensure adequate circulation. However, in the late phase of acute liver failure complications that often lead to death are cerebral swelling and brainstem edema, which are considered to result from increasing intracranial pressure (ICP). In former studies cerebral venous pressure (CVP) and ICP were reported to be independent entities. Acute liver failure was induced in 25 German land race pigs by acetaminophen intoxication. CVP and ICP were measured continuously. Hydroxyethyl starch solution and noradrenalin were administered to stabilize the circulation at a mean arterial pressure above 60mmHg. There is an increasing correlation in quantity and quality between the CVP and ICP in the last 24 h before exitus. Beginning with a slope of 0.24 (ICP against CVP) and a low correlation coefficient of 0.08. 24h before exitus, this situation remained stable until 16 h to exitus (m = 0.22, r = 0.1). The correlation increased from 16 to 8 h prior to exitus to a slope of m = 0.5 and a correlation of r = 0.3 and remained until exitus. In late acute liver failure it seems therefore clinically reasonable to keep circulation within an adequate range by the use of noradrenalin and to avoid fluid overload.


Assuntos
Pressão Venosa Central/fisiologia , Pressão Intracraniana/fisiologia , Falência Hepática Aguda/fisiopatologia , Acetaminofen/efeitos adversos , Animais , Modelos Animais de Doenças , Feminino , Falência Hepática Aguda/induzido quimicamente , Microdiálise , Suínos
16.
Neurocrit Care ; 17(2): 271-80, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22547041

RESUMO

BACKGROUND: We investigated in a porcine model of anhepatic acute liver failure (ALF), the value of two parameters describing cerebrovascular autoregulatory capacity, pressure reactivity index (PRx) and brain tissue oxygen pressure reactivity (ORx), regarding their power to predict the development of intracranial hypertension. METHODS: In six pigs, hepatectomy was performed. Only one animal was sham operated. All animals received neuromonitoring including arterial blood pressure, intracranial pressure (ICP), and brain tissue partial oxygen pressure (P(br)O(2)). The average time of neuromonitoring was 31.0 h. Cerebral perfusion pressures (CPP), cerebrovascular pressure reactivity index (PRx) and brain tissue oxygen reactivity index (ORx) were calculated. RESULTS: Perioperative disturbance of AR improved within 4 h after surgery. From 6 to 16 h post hepatectomy, ICP did slowly increase by 4 mmHg from baseline; CPP remained stable around 40 mmHg. PRx and ORx, however, indicated in this period a progressive loss of AR, reflected in a decrease of P(br)O(2) despite unchanged CPP. Beyond 16 h, ICP rose quickly. At CPP levels below 35 mmHg, P(br)O(2) fell to ischemic levels. CONCLUSIONS: The loss of cerebrovascular autoregulatory capacity, indicated by a rise of PRx and ORx precedes the final crisis of uncontrollable intracranial hypertension in this animal model by hours. During this phase cerebral blood flow, as reflected in tissue oxygenation, deteriorates despite unchanged CPP. Monitoring of AR during ALF therefore seems to carry the power to identify a risk for development of critical CBF and intracranial hypertension.


Assuntos
Encéfalo/fisiopatologia , Circulação Cerebrovascular/fisiologia , Hipertensão Intracraniana/fisiopatologia , Falência Hepática Aguda/complicações , Oxigênio/metabolismo , Animais , Pressão Sanguínea , Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , Modelos Animais de Doenças , Progressão da Doença , Hepatectomia , Homeostase/fisiologia , Hipertensão Intracraniana/complicações , Pressão Intracraniana/fisiologia , Pressão Parcial , Suínos
17.
Polymers (Basel) ; 14(23)2022 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-36501539

RESUMO

This study investigates the initial stage of the thermo-mechanical crystallization behavior for uni- and biaxially stretched polyethylene. The models are based on a mesoscale molecular dynamics approach. We take constraints that occur in real-life polymer processing into account, especially with respect to the blowing stage of the extrusion blow-molding process. For this purpose, we deform our systems using a wide range of stretching levels before they are quenched. We discuss the effects of the stretching procedures on the micro-mechanical state of the systems, characterized by entanglement behavior and nematic ordering of chain segments. For the cooling stage, we use two different approaches which allow for free or hindered shrinkage, respectively. During cooling, crystallization kinetics are monitored: We precisely evaluate how the interplay of chain length, temperature, local entanglements and orientation of chain segments influence crystallization behavior. Our models reveal that the main stretching direction dominates microscopic states of the different systems. We are able to show that crystallization mainly depends on the (dis-)entanglement behavior. Nematic ordering plays a secondary role.

18.
Adv Clin Exp Med ; 31(12): 1335-1342, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36047898

RESUMO

BACKGROUND: Acetaminophen intoxication has become the leading cause of acute liver failure (ALF) in Europe and the USA. OBJECTIVES: To identify early biomarkers in order to predict the development of ALF in a porcine model of acetaminophen intoxication. MATERIAL AND METHODS: Six German Landrace pigs received a single acetaminophen bolus of 1 g/kg body weight via a jejunal catheter. Cytokines and laboratory parameters were analyzed at 8-hour intervals for a total of 40 h. RESULTS: Three of the 6 animals survived the intoxication. The nonsurviving animals had an increase in serum lactate and interleukin (IL)-6, with a simultaneous decrease in prothrombin time (PT) and albumin concentration 8 h after intoxication. In all nonsurviving animals, elevated levels of tumor necrosis factor alpha (TNF-α) at baseline before intoxication and during the course of ALF were observed. The acetaminophen serum concentrations and toxicokinetics did not differ between the nonsurviving and surviving animals. Methemoglobinemia was proportional to the administered doses and acetaminophen blood levels, but methemoglobinemia did not affect survival. CONCLUSIONS: Tumor necrosis factor alpha, IL-6, lactate, prothrombin time, and albumin blood concentration were identified as early predictors of outcome after acetaminophen intoxication. An elevated TNF-α level before acetaminophen exposure was the earliest prognostic marker for a lethal outcome. Therefore, it could serve as a very early indicator of prognosis.


Assuntos
Falência Hepática Aguda , Metemoglobinemia , Suínos , Animais , Acetaminofen , Fator de Necrose Tumoral alfa , Projetos Piloto , Biomarcadores , Lactatos , Albuminas
19.
Sci Rep ; 12(1): 10243, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35715523

RESUMO

Surgical therapy of duodenal perforation into the retroperitoneum entails high morbidity. Conservative treatment and endoscopic negative pressure therapy have been suggested as promising therapeutic alternatives. We aimed to retrospectively assess outcomes of patients treated for duodenal perforation to the retroperitoneum at our department. A retrospective analysis of all patients that were treated for duodenal perforation to the retroperitoneum at our institution between 2010 and 2021 was conducted. Different therapeutic approaches with associated complications within 30 days, length of in-hospital stay, number of readmissions and necessity of parenteral nutrition were assessed. We included thirteen patients in our final analysis. Six patients underwent surgery, five patients were treated conservatively and two patients received interventional treatment by endoscopic negative pressure therapy. Length of stay was shorter in patients treated conservatively. One patient following conservative and surgical treatment each was readmitted to hospital within 30 days after initial therapy whereas no readmissions after interventional treatment occurred. There was no failure of therapy in patients treated without surgery whereas four (66.7%) of six patients required revision surgery following primary surgical therapy. Conservative and interventional treatment were associated with fewer complications than surgical therapy which involves high morbidity. Conservative and interventional treatment using endoscopic negative pressure therapy in selected patients might constitute appropriate therapeutic alternatives for duodenal perforations to the retroperitoneum.


Assuntos
Úlcera Duodenal , Perfuração Intestinal , Úlcera Péptica Perfurada , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Úlcera Duodenal/complicações , Humanos , Perfuração Intestinal/etiologia , Perfuração Intestinal/cirurgia , Úlcera Péptica Perfurada/complicações , Estudos Retrospectivos , Resultado do Tratamento
20.
J Nephrol ; 35(1): 311-316, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34236694

RESUMO

BACKGROUND: In patients with obesity and end-stage kidney disease, implantation of the peritoneal dialysis (PD) catheter may be complicated by increased abdominal circumference or skin folds. Relocation of the implantation site to the upper abdomen could solve this problem. However, this would require an extended catheter. METHODS: We developed an extended PD catheter based on a swan neck Missouri PD catheter with the help of two adaptors and a straight intraperitoneal extension segment. The extended catheter was assembled intraoperatively, and its length was adjusted individually to ensure correct positioning. After the operation, PD was commenced and handled as usual. RESULTS: In the period from 2011 to 2021, we implanted 31 extended PD catheters in 29 patients (38% men) with end-stage renal failure and obesity. Median age was 53 (range 28-77) years and body mass index was 35.5 (range 26.4-46.9) kg/m2. The postoperative course was unremarkable except for seroma formation in one patient and dialysate leakage in another. Continuous ambulatory peritoneal dialysis (CAPD) was initiated in 20 and APD in 9 patients. The achieved median Kt/V was 2.10 (range 1.50-3.10). During the follow-up period lasting up to 51 months, there was one case of intraperitoneal catheter disconnection due to an avoidable handling error. The peritonitis rate was 1:40 months. The 1- and 2-year catheter survival was 92% and 67%, respectively, and paralleled patient survival. CONCLUSIONS: When using a PD catheter with an intraperitoneal extension, PD catheter implantation can be relocated to the upper abdomen in patients with obesity, thus providing optimal position and easy surgical access.


Assuntos
Diálise Peritoneal Ambulatorial Contínua , Diálise Peritoneal , Peritonite , Adulto , Idoso , Cateterismo/efeitos adversos , Cateteres de Demora/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/diagnóstico , Obesidade/terapia , Diálise Peritoneal/efeitos adversos , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Peritonite/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA