Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 22(11): 4452-4458, 2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35605204

RESUMO

Ultrafast control of magnetization on the nanometer length scale, in particular all-optical switching, is key to putting ultrafast magnetism on the path toward future technological application in data storage technology. However, magnetization manipulation with light on this length scale is challenging due to the wavelength limitations of optical radiation. Here, we excite transient magnetic gratings in a GdFe alloy with a periodicity of 87 nm by the interference of two coherent femtosecond light pulses in the extreme ultraviolet spectral range. The subsequent ultrafast evolution of the magnetization pattern is probed by diffraction of a third, time-delayed pulse tuned to the Gd N-edge at a wavelength of 8.3 nm. By examining the simultaneously recorded first and second order diffractions and by performing reference real-space measurements with a wide-field magneto-optical microscope with femtosecond time resolution, we can conclusively demonstrate the ultrafast emergence of all-optical switching on the nanometer length scale.

2.
Angew Chem Int Ed Engl ; 62(27): e202303882, 2023 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-37084076

RESUMO

The inherent formation of salt waste in C-H carboxylations is a key obstacle precluding the utilization of CO2 as C1 building block in the industrial synthesis of base chemicals. This challenge is addressed in a circular process for the production of the C4 base chemical dimethyl succinate from CO2 and acetylene. At moderate CO2 pressures, acetylene is doubly carboxylated in the presence of cesium carbonate. Hydrogenation of the C-C triple bond stabilizes the product against decarboxylation. By increasing the CO2 pressure to 70 bar, the medium is reversibly acidified, allowing an esterification of the succinate salt with methanol. The cesium base and the hydrogenation catalyst are regenerated and can be reused. This provides the proof of concept for a salt-free route to C4 chemicals from biogas (CH4 /CO2 ). The origin of this reversible acidity switch and the critical roles of the cesium base and the NMP/MeOH solvents were elucidated by thermodynamic modeling.

3.
Cost Eff Resour Alloc ; 19(1): 20, 2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33827599

RESUMO

BACKGROUND: Certification of multidisciplinary tumor centers is nowadays seen as the gold standard in modern oncological therapy for optimization and realization of guideline-based therapy and better outcomes. Single cases are reimbursed based on diagnosis-related groups (DRG). We aimed to review efficiency, cost analysis, and profitability following a certification. METHODS: Tumor board certification at the university hospital Aachen was implemented in 2013. We compared 1251 cases of oropharyngeal cancer treated from 2008 to 2017 before and after certification. For this purpose, several patient characteristics, surgery, and stay-related constants, as well as expenses and reimbursement heights were analyzed statistically. RESULTS: Following certification, the total case and patient number, surgery duration, hours of mechanical ventilation, case mix index points, DRG reimbursements as well as the costs increased significantly, whereas days of intensive care unit, amount of blood transfusions, patient clinical complexity level (PCCL) and the overall stay were significantly lowered. No changes were observed for the patient's age and gender distribution. Also, the predetermined stay duration stayed constant. CONCLUSIONS: Certification of head-neck tumor centers causes a concentration of more complex cases requiring higher surgical efforts, which can be processed more efficiently due to a higher level of professionalism. Despite their benefits in cancer care, without compensation, centers may be struggling to cover their expenses in a system, which continuously underestimates them.

4.
Phys Rev Lett ; 119(19): 197202, 2017 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-29219516

RESUMO

By comparing femtosecond laser pulse induced ferro- and antiferromagnetic dynamics in one and the same material-metallic dysprosium-we show both to behave fundamentally different. Antiferromagnetic order is considerably faster and much more efficiently reduced by optical excitation than its ferromagnetic counterpart. We assign the fast and extremely efficient process in the antiferromagnet to an interatomic transfer of angular momentum within the spin system. Our findings imply that this angular momentum transfer channel is effective in other magnetic metals with nonparallel spin alignment. They also point out a possible route towards energy-efficient spin manipulation for magnetic devices.

5.
J Synchrotron Radiat ; 23(Pt 3): 700-11, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27140149

RESUMO

The slicing facility FemtoSpeX at BESSY II offers unique opportunities to study photo-induced dynamics on femtosecond time scales by means of X-ray magnetic circular dichroism, resonant and non-resonant X-ray diffraction, and X-ray absorption spectroscopy experiments in the soft X-ray regime. Besides femtosecond X-ray pulses, slicing sources inherently also produce a so-called `halo' background with a different time structure, polarization and pointing. Here a detailed experimental characterization of the halo radiation is presented, and a method is demonstrated for its correct and unambiguous removal from femtosecond time-resolved data using a special laser triggering scheme as well as analytical models. Examples are given for time-resolved measurements with corresponding halo correction, and errors of the relevant physical quantities caused by either neglecting or by applying a simplified model to describe this background are estimated.

6.
J Synchrotron Radiat ; 21(Pt 2): 380-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24562559

RESUMO

A new concept for shortening hard X-ray pulses emitted from a third-generation synchrotron source down to few picoseconds is presented. The device, called the PicoSwitch, exploits the dynamics of coherent acoustic phonons in a photo-excited thin film. A characterization of the structure demonstrates switching times of ≤ 5 ps and a peak reflectivity of ∼10(-3). The device is tested in a real synchrotron-based pump-probe experiment and reveals features of coherent phonon propagation in a second thin film sample, thus demonstrating the potential to significantly improve the temporal resolution at existing synchrotron facilities.

7.
Phys Rev Lett ; 112(9): 097602, 2014 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-24655276

RESUMO

We apply ultrafast x-ray diffraction with femtosecond temporal resolution to monitor the lattice dynamics in a thin film of multiferroic BiFeO3 after above-band-gap photoexcitation. The sound-velocity limited evolution of the observed lattice strains indicates a quasi-instantaneous photoinduced stress which decays on a nanosecond time scale. This stress exhibits an inhomogeneous spatial profile evidenced by the broadening of the Bragg peak. These new data require substantial modification of existing models of photogenerated stresses in BiFeO3: the relevant excited charge carriers must remain localized to be consistent with the data.

8.
Struct Dyn ; 11(5): 054303, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39398360

RESUMO

Time-resolved soft-x-ray-diffraction experiments give access to microscopic processes in a broad range of solid-state materials by probing ultrafast dynamics of ordering phenomena. While laboratory-based high-harmonic generation (HHG) light sources provide the required photon energies, their limited photon flux is distributed over a wide spectral range, rendering typical monochromatic diffraction schemes challenging. Here, we present a scheme for energy-dispersive soft-x-ray diffraction with femtosecond temporal resolution and photon energies across the water window from 200 to 600 eV. The experiment utilizes the broadband nature of the HHG emission to efficiently probe large slices in reciprocal space. As a proof-of-concept, we study the laser-induced structural dynamics of a Mo/Si superlattice in an ultrafast, non-resonant soft-x-ray diffraction experiment. We extract the underlying strain dynamics from the measured shift of its first order superlattice Bragg peak in reciprocal space at photon energies around 500 eV via soft-x-ray scattering simulations.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38940951

RESUMO

PURPOSE: The orbital floor is frequently involved in head trauma. Current evidence on the use of reconstruction materials for orbital floor repair is inconclusive. Accordingly, this study aimed to compare the impact of polydioxanone (PDS) foil thickness on reconstruction of the orbital geometry after isolated orbital floor fractures. METHODS: Standardized isolated orbital floor fractures were symmetrically created in 11 cadaver heads that provided 22 orbits. PDS foils with thicknesses of 0.25-0.5 mm were inserted. Computed tomography (CT) scans of the native, fractured, and reconstructed orbits were obtained, and orbital volume, orbital height, and foil bending were measured. RESULTS: Orbital volume and height significantly (p < 0.01) increased after the creation of isolated orbital floor fractures and significantly (p = 0.001) decreased with overcorrection of the orbital geometry after orbital floor reconstruction with PDS 0.25 mm or PDS 0.5 mm. The orbital geometry reconstruction rate did not differ significantly with respect to foil thickness. However, compared to PDS 0.5 mm, the use of PDS 0.25 mm resulted in quantitatively higher reconstructive accuracy and a restored orbital volume that did not significantly differ from the initial volume. CONCLUSION: Orbital floors subjected to isolated fractures were successfully reconstructed using PDS regardless of foil thickness, with overcorrection of the orbital geometry. Due to its lower flexural stiffness, PDS 0.25 mm appeared to provide more accurate orbital geometry reconstruction than PDS 0.5 mm, although no significant difference in reconstructive accuracy between PDS 0.25 mm and PDS 0.5 mm was observed in this cadaveric study.

10.
Sci Adv ; 10(36): eadp6015, 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39241073

RESUMO

The advent of free electron lasers has opened the opportunity to explore interactions between extreme ultraviolet (EUV) photons and collective excitations in solids. While EUV transient grating spectroscopy, a noncollinear four-wave mixing technique, has already been applied to probe coherent phonons, the potential of EUV radiation for studying nanoscale spin waves has not been harnessed. Here we report EUV transient grating experiments with coherent magnons in Fe/Gd ferrimagnetic multilayers. Magnons with tens of nanometers wavelengths are excited by a pair of femtosecond EUV pulses and detected via diffraction of a probe pulse tuned to an absorption edge of Gd. The results unlock the potential of nonlinear EUV spectroscopy for studying magnons and provide a tool for exploring spin waves in a wave vector range not accessible by established inelastic scattering techniques.

11.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862537

RESUMO

We present a laser-driven, bright, and broadband (50 to 1500 eV) soft-x-ray plasma source with <10 ps pulse duration. This source is employed in two complementary, laboratory-scale beamlines for time-resolved, magnetic resonant scattering and spectroscopy, as well as near-edge x-ray absorption fine-structure (NEXAFS) spectroscopy. In both beamlines, dedicated reflection zone plates (RZPs) are used as single optical elements to capture, disperse, and focus the soft x rays, reaching resolving powers up to E/ΔE > 1000, with hybrid RZPs at the NEXAFS beamline retaining a consistent E/ΔE > 500 throughout the full spectral range, allowing for time-efficient data acquisition. We demonstrate the versatility and performance of our setup by a selection of soft-x-ray spectroscopy and scattering experiments, which so far have not been possible on a laboratory scale. Excellent data quality, combined with experimental flexibility, renders our approach a true alternative to large-scale facilities, such as synchrotron-radiation sources and free-electron lasers.

12.
Sci Adv ; 8(20): eabn5127, 2022 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35594356

RESUMO

Extending nonlinear spectroscopic techniques into the x-ray domain promises unique insight into photoexcited charge dynamics, which are of fundamental and applied interest. We report on the observation of a third-order nonlinear process in lithium fluoride (LiF) at a free-electron laser. Exploring the yield of four-wave mixing (FWM) in resonance with transitions to strongly localized core exciton states versus delocalized Bloch states, we find resonant FWM to be a sensitive probe for the degree of charge localization: Substantial sum- and difference-frequency generation is observed exclusively when in a one- or three-photon resonance with a LiF core exciton, with a dipole forbidden transition affecting details of the nonlinear response. Our reflective geometry-based approach to detect FWM signals enables the study of a wide variety of condensed matter sample systems, provides atomic selectivity via resonant transitions, and can be easily scaled to shorter wavelengths at free-electron x-ray lasers.

13.
Struct Dyn ; 8(3): 034305, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34235231

RESUMO

During the last two decades, a variety of models have been developed to explain the ultrafast quenching of magnetization following femtosecond optical excitation. These models can be classified into two broad categories, relying either on a local or a non-local transfer of angular momentum. The acquisition of the magnetic depth profiles with femtosecond resolution, using time-resolved x-ray resonant magnetic reflectivity, can distinguish local and non-local effects. Here, we demonstrate the feasibility of this technique in a pump-probe geometry using a custom-built reflectometer at the FLASH2 free-electron laser (FEL). Although FLASH2 is limited to the production of photons with a fundamental wavelength of 4 nm ( ≃ 310 eV ), we were able to probe close to the Fe L 3 edge ( 706.8 eV ) of a magnetic thin film employing the third harmonic of the FEL. Our approach allows us to extract structural and magnetic asymmetry signals revealing two dynamics on different time scales which underpin a non-homogeneous loss of magnetization and a significant dilation of 2 Å of the layer thickness followed by oscillations. Future analysis of the data will pave the way to a full quantitative description of the transient magnetic depth profile combining femtosecond with nanometer resolution, which will provide further insight into the microscopic mechanisms underlying ultrafast demagnetization.

14.
Australas Phys Eng Sci Med ; 33(4): 335-40, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21286892

RESUMO

Due to the difficulty in obtaining expected baseline values from the supplier for the performance testing of the Fujifilm FCR Capsula XL computed radiography system, performance test results from the acceptance testing of 42 Capsula systems were reviewed. Guidance ranges are provided for nine system performance tests which can be applied to future testing of calibrated systems.


Assuntos
Análise de Falha de Equipamento/métodos , Tomografia Computadorizada por Raios X/normas , Filme para Raios X/normas , Calibragem
15.
Materials (Basel) ; 13(19)2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32977513

RESUMO

Magnesium alloys have exhibited a rapid rate of corrosion and thus early implant failure, so this study was designed to investigate the longer-term effects and in particular on wound closure. The aim of the study is to evaluate Mg-Ca-Zn Alloys as promising biodegradable implants in the field of maxillofacial surgery, which have so far never been evaluated for the changing conditions from a saliva to a serum-like environment after wound closure. Magnesium-0.6/calcium-0.8 wt.% zinc alloys were either immersed for 10 days in artificial saliva or 10 days in Hank's salt solution as control groups. The test group was transferred from artificial saliva to Hank's salt solution after 5 days in order to simulate wound closure. Corrosion rates were determined by immersion testing. Additional electron microscopy and energy dispersive X-ray spectroscopy (EDX) were performed. Prior artificial saliva exposure led to significantly decreased (p = 0.0272) corrosion rates after transfer to Hank's solution in comparison to sole Hank's solution exposure (0.1703 vs. 0.6675 mg/(cm2·day)) and sole artificial saliva exposure (0.3180 mg/(cm2·day)), which both exhibit a strong increase after 5 days. The results were in accordance with the scanning electron microscopy and EDX pictures. Prior saliva exposure could protect from increasing corrosion rates after wound closure. Thus Mg-Ca-Zn Alloys are promising future implant alloys in oral surgery, whereas other surgical fields without saliva exposure have to deal with accelerated corrosion rates after 5 days.

16.
Eur J Radiol ; 125: 108917, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32120276

RESUMO

PURPOSE: Since accurate diagnosis of inflammatory jaw diseases is still challenging, this study investigated the performance of three phase bone scintigraphy including SPECT/CT in the assessment of correct diagnosis and size of the affected bone tissue. METHOD: This retrospective study contained 31 patients with suspected jaw-related osteoradionecrosis, osteomyelitis or medication-related osteonecrosis of the jaw, which underwent 3-phase bone scintigraphy including SPECT/CT. Results were reviewed by two nuclear medicine physicians. Positive cases received surgery; negative ones were followed-up for six months. Both served as reference standard. Inflamed bone length was measured in the SPECT/CT images and postoperatively by a pathologist. RESULTS: 19 out of 20 positive cases and 10 out of 11 negative ones were classified correctly by SPECT/CT (sensitivity 95 %, specificity 91 %, accuracy 94 %, positive predictive value 95 %, negative predictive value 91 %). Regarding the length of affected bone, no significant difference (p = 0.23) could be observed between SPECT/CT and postoperative obtained values. Both correlated significantly (r = 0.86, p = 0.0001). CONCLUSION: SPECT/CT can safely detect different kinds of inflammatory jaw pathologies compared to other conventional imaging modalities. Lack of specificity of conventional scintigraphy ranging from 17 % to 71 % in earlier studies could be improved by adding CT-analysis. Additionally, SPECT/CT assists the surgeon in determining the expansion of the process (with focus on the length) preoperatively and thereby optimizing surgery planning.


Assuntos
Doenças Maxilomandibulares/diagnóstico por imagem , Osteomielite/diagnóstico por imagem , Osteonecrose/diagnóstico por imagem , Osteorradionecrose/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Arcada Osseodentária/diagnóstico por imagem , Arcada Osseodentária/patologia , Doenças Maxilomandibulares/patologia , Masculino , Pessoa de Meia-Idade , Osteomielite/patologia , Osteonecrose/patologia , Osteorradionecrose/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
17.
Rev Sci Instrum ; 91(9): 093001, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33003828

RESUMO

Further advances in the field of ultrafast magnetization dynamics require experimental tools to measure the spin and electron dynamics with element-specificity and femtosecond temporal resolution. We present a new laboratory setup for two complementary experiments with light in the extreme ultraviolet (XUV) spectral range. One experiment is designed for polarization-dependent transient spectroscopy, particularly for simultaneous measurements of magnetic circular dichroism (MCD) at the 3p resonances of the 3d transition metals Fe, Co, and Ni. The second instrument is designed for resonant small-angle scattering experiments with monochromatic light allowing us to monitor spin dynamics with spatial information on the nanometer scale. We combine a high harmonic generation (HHG) source with a phase shifter to obtain XUV pulses with variable polarization and a flux of about (3 ± 1) × 1010 photons/s/harmonic at 60 eV at the source. A dedicated reference spectrometer effectively reduces the intensity fluctuations of the HHG spectrum to below 0.12% rms. We demonstrate the capabilities of the setup by capturing the energy- and polarization-dependent absorption of a thin Co film as well as the time-resolved small-angle scattering in a magnetic-domain network of a Co/Pt multilayer. The new laboratory setup allows systematic studies of optically induced spin and electron dynamics with element-specificity, particularly with MCD as the contrast mechanism with femtosecond temporal resolution and an unprecedented signal-to-noise ratio.

18.
Nat Commun ; 11(1): 871, 2020 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-32054855

RESUMO

Optically driven spin transport is the fastest and most efficient process to manipulate macroscopic magnetization as it does not rely on secondary mechanisms to dissipate angular momentum. In the present work, we show that such an optical inter-site spin transfer (OISTR) from Pt to Co emerges as a dominant mechanism governing the ultrafast magnetization dynamics of a CoPt alloy. To demonstrate this, we perform a joint theoretical and experimental investigation to determine the transient changes of the helicity dependent absorption in the extreme ultraviolet spectral range. We show that the helicity dependent absorption is directly related to changes of the transient spin-split density of states, allowing us to link the origin of OISTR to the available minority states above the Fermi level. This makes OISTR a general phenomenon in optical manipulation of multi-component magnetic systems.

19.
Atherosclerosis ; 286: 163-171, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30910225

RESUMO

BACKGROUND AND AIMS: Members of the family of a disintegrin and metalloproteinases (ADAMs) and their substrates have been previously shown to modulate the inflammatory response in cardiac diseases, but studies investigating the relevance of ADAM8 are still rare. Our aim is to provide evidence for the inflammatory dysregulation of ADAM8 in vascular diseases and its association with disease severity. METHODS: Western-type diet fed Apoe-/- and Ldlr-/- mice and artery ligation served as murine model for atherosclerosis and myocardial infarction, respectively. Human bypass grafts were used to study the association with coronary artery disease (CAD), with the simplified acute physiology score II (SAPS II) as a measure of postoperative organ dysfunction. Human primary vascular and blood cells were analyzed under basal and inflammatory conditions. mRNA levels were determined by RT-qPCR, ADAM8 protein levels by ELISA, immunohistochemistry or flow cytometry. RESULTS: ADAM8/ADAM8 expression is associated with atherosclerosis and CAD such as myocardial infarction in both mice and humans, especially in endothelial cells and leukocytes. We observed a strong in vivo and in vitro correlation of ADAM8 with the vascular disease markers VCAM-1, ICAM-1, TNF, IL-6, and CCL-2. Serum analysis revealed a significant elevation of soluble ADAM8 serum levels correlating with soluble CXCL16 levels and SAPS II. CONCLUSIONS: We demonstrate a general association of ADAM8 with cardiovascular diseases in mice and humans predominantly acting in endothelial cells and leukocytes. The correlation with postoperative organ dysfunctions in CAD patients highlights the value of further studies investigating the specific function of ADAM8 in cardiovascular diseases.


Assuntos
Proteínas ADAM/biossíntese , Antígenos CD/biossíntese , Aterosclerose/metabolismo , Proteínas de Membrana/biossíntese , Infarto do Miocárdio/metabolismo , Animais , Células Cultivadas , Feminino , Humanos , Leucócitos Mononucleares , Masculino , Camundongos , Pessoa de Meia-Idade , Índice de Gravidade de Doença
20.
Struct Dyn ; 4(5): 054902, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28852689

RESUMO

We present a setup combining a liquid flatjet sample delivery and a MHz laser system for time-resolved soft X-ray absorption measurements of liquid samples at the high brilliance undulator beamline UE52-SGM at Bessy II yielding unprecedented statistics in this spectral range. We demonstrate that the efficient detection of transient absorption changes in transmission mode enables the identification of photoexcited species in dilute samples. With iron(II)-trisbipyridine in aqueous solution as a benchmark system, we present absorption measurements at various edges in the soft X-ray regime. In combination with the wavelength tunability of the laser system, the set-up opens up opportunities to study the photochemistry of many systems at low concentrations, relevant to materials sciences, chemistry, and biology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA