1.
J Surg Res ; 160(2): 277-81, 2010 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19628225

RESUMO

BACKGROUND: Margin status in breast lumpectomy procedures is a prognostic factor for local recurrence and the need to obtain clear margins is often a cause for repeated surgical procedures. A recently developed device for real-time intraoperative margin assessment (MarginProbe; Dune Medical Devices, Caesarea, Israel), was clinically tested. The work presented here looks at the diagnostic performance of the device. METHODS: The device was applied to freshly excised lumpectomy and mastectomy specimens at specific tissue measurement sites. These measurement sites were accurately marked, cut out, and sent for histopathologic analysis. Device readings (positive or negative) were compared with histology findings (namely malignant, containing any microscopically detected tumor, or nonmalignant) on a per measurement site basis. The sensitivity and specificity of the device was computed for the full dataset and for additional relevant subgroups. RESULTS: A total of 869 tissue measurement sites were obtained from 76 patients, 753 were analyzed, of which 165 were cancerous and 588 were nonmalignant. Device performance on relatively homogeneous sites was: sensitivity 1.00 (95% CI: 0.85-1), specificity 0.87 (95% CI: 0.83-0.90). Performance for the full dataset was: sensitivity 0.70 (95% CI: 0.63-0.77), specificity 0.70 (95% CI: 0.67-0.74). Device sensitivity was estimated to change from 56% to 97% as the cancer feature size increased from 0.7 mm to 6.6 mm. Detection rate of samples containing pure DCIS clusters was not different from rates of samples containing IDC. CONCLUSIONS: The device has high sensitivity and specificity in distinguishing between normal and cancer tissue even down to small cancer features.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Mastectomia Segmentar , Patologia Clínica/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Adulto , Biópsia , Mama/patologia , Mama/cirurgia , Feminino , Humanos , Cuidados Intraoperatórios/instrumentação , Cuidados Intraoperatórios/normas , Patologia Clínica/normas , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectroscopia de Luz Próxima ao Infravermelho/normas
2.
Harefuah ; 146(4): 258-9, 320, 2007 Apr.
Artigo em Hebraico | MEDLINE | ID: mdl-17476928

RESUMO

Diabetic mastopathy is an uncommon disorder of the breast seen mostly in young women suffering from type 1 diabetes mellitus. The presenting symptom is a rapidly growing breast lump that may simulate breast cancer. Clinically and radiologically it can be indistinguishable from breast carcinoma. Recognizing this clinical entity, in addition to close collaboration between the clinician and the pathologist can facilitate its early diagnosis, avoiding unnecessary alarm for the patient. A 36 years old patient with a long-standing type 1 diabetes mellitus was admitted to surgery for a rapidly growing left breast lump. Excisional biopsy of the lump revealed diabetic mastopathy.


Assuntos
Diabetes Mellitus Tipo 1/complicações , Doença da Mama Fibrocística/patologia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética
5.
Am J Surg ; 196(4): 483-9, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18809049

RESUMO

BACKGROUND: This randomized, double-arm trial was designed to study the benefit of a novel device (MarginProbe, Dune Medical Devices, Caesarea, Israel) in intraoperative margin assessment for breast-conserving surgery (BCS) and the associated reduction in reoperations. METHODS: In the device group, the probe was applied to the lumpectomy specimen and additional tissue was excised according to device readings. Study arms were compared by reoperation rates and by correct surgical reaction confirmed by histology. RESULTS: Three hundred patients were enrolled. Device use was associated with improved correct surgical reaction, defined as additional re-excision in all histologically detected positive margins, with tumor within 1 mm of inked margin. The repeat lumpectomy rate was significantly reduced by 56% in the device arm: 5.6% versus 12.7% in the control arm. There were no differences in excised tissue volume or cosmetic outcome. CONCLUSIONS: Intraoperative use of the MarginProbe for positive margin detection is safe and effective in BCS and decreases the rate of repeat operations.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Cuidados Intraoperatórios/instrumentação , Mastectomia Segmentar/instrumentação , Desenho de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação , Resultado do Tratamento