Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(1): 194-201, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38037296

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS: Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS: Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION: Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.


Assuntos
Estenose da Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Desenho de Prótese
2.
Am Heart J ; 247: 112-122, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35149038

RESUMO

BACKGROUND: Despite continuous improvements in transcatheter aortic valve implantation (TAVI), periprocedural strokes remain a devastating complication. Randomized controlled trials failed to demonstrate a reduction in clinically apparent strokes or mortality after TAVI due to cerebral embolic protection (CEP). To identify potential targets of CEP strategies during TAVI, we evaluated affected brain regions, and temporal patterns of stroke onset in a routine clinical sample. METHODS AND RESULTS: A total of 3,164 consecutive patients treated with TAVI from 2008 to 2019 at a single center were screened for cerebrovascular events. Affected cerebral regions were determined according to clinical symptoms and brain imaging. Rates of disabling stroke and non-disabling stroke at 30 days were 2.2% and 1.4%, respectively. The frequency of all strokes decreased from 5.0% to 3.0% over time (P = .012). Patients with impaired left-ventricular function (OR 2.19), increased CHA2DS2-VASc (OR 1.39) and moderate/severe spontaneous echo contrast (OR 3.60) had a higher stroke risk. Acute symptom onset occurred during TAVI (19.4%), within 24 hours (40.3%) or later (25.0%); 98.3% of strokes were of ischemic origin. In intraprocedural strokes, 53.2% of lesions were found in locations considered protected by current CEP devices, and 37.5% of patients with intraprocedural strokes were exclusively affected in these areas. Baseline or procedural parameters were not associated with embolic distribution patterns. CONCLUSIONS: Most strokes occurred early after TAVI - but not necessarily during the procedure - and affected multiple brain regions only partially protected by current CEP devices. Efficient prevention of cerebrovascular events may require strategies beyond the TAVI procedure to minimize stroke risk and additional randomized controlled trials will be required to clarify the role of CEP in efficient stroke prevention during TAVI.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Implante de Prótese de Valva Cardíaca , Embolia Intracraniana , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Encéfalo/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
J Endovasc Ther ; 28(5): 676-681, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34032470

RESUMO

PURPOSE: Endovascular repair of chronic thoracoabdominal aortic dissection with aneurysmal degeneration presents a therapeutic challenge when one or more visceral branches arise from the false lumen without an adjacent reentry. The chronic dissection flap can be thick and resistant to flap fenestration with standard techniques. TECHNIQUE: The powered cheese wire technique facilitates cutting of a dissection flap using electrical current on a noninsulated through-and-through wire segment. The mid-shaft of the guidewire is denuded and kinked to form the "flying V" configuration. This solution is based on the BASILICA procedure, which uses electrosurgery to split aortic valve tissue lengthwise prior to transcatheter aortic valve replacement to prevent coronary artery obstruction. We demonstrate the technique in a case of branched endovascular aortic repair of a complex thoracoabdominal dissecting aneurysm in which a renal artery from the false lumen was catheterized by creating a powered cheese wire fenestration. CONCLUSION: The powered cheese wire technique is an effective approach to access false lumen originating branches during endovascular aortic repair of chronic aortic dissections.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Fluoroscopia , Humanos , Resultado do Tratamento
4.
Am Heart J ; 225: 138-148, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32502877

RESUMO

BACKGROUND: Compared to high gradient aortic stenosis (AS), patients with low-flow, low-gradient AS have higher mortality after transcatheter aortic valve replacement (TAVR), but distinct outcome predictors in this patient subset are yet to be determined. The present study investigated the prognostic impact of aortic valve calcification (AVC) in patients with low-flow, low-gradient AS undergoing TAVR. METHODS: This retrospective single-center analysis includes all patients undergoing TAVR for severe low-flow, low-gradient AS (n = 526), ie, low EF low gradient AS (LEF-LG AS; n = 290) and paradoxical low-flow, low-gradient AS (PLF-LG AS; n = 236), in whom AVC was quantified from contrast-enhanced multislice computed tomography images. AVCdensity was defined as calcium volume per annulus area. Patients were trichotomized according to sex-specific AVCdensity tertiles in both subgroups. All-cause mortality was assessed by Kaplan-Meier analyses and independent outcome predictors were determined by multivariable analyses. RESULTS: In both subgroups, patients with high AVCdensity had higher mean transvalvular gradients at baseline and higher rates of PVL after TAVR. High AVCdensity was associated with lowest 1- and 3-year mortality after TAVR in the LEF-LG AS but not in the PLF-LG AS group. According to multivariable analysis AVCdensity was independently associated with better survival in LEF-LG AS patients (HR 0.73 [0.60-0.88], P = .0011), but not in those with PLF-LG AS (HR 0.91 [0.73-1.14], P = .42). CONCLUSIONS: Quantification of AVC may not only be of diagnostic but also of prognostic value, as it facilitates the selection of LEF-LG AS patients with higher probability of beneficial outcome after TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/classificação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/fisiopatologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico
5.
Catheter Cardiovasc Interv ; 91(4): 827-830, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-27535346

RESUMO

Mitraclip is an alternative therapeutic option for severe functional mitral regurgitation (MR) with reduced ejection fraction, especially in patients with high surgical risk. Although the Mitraclip was reported as an effective therapy in patients who fulfilled the anatomical criteria of the EVEREST trial, it is still uninvestigated whether the therapy is also feasible and beneficial in patients outside the indication criteria of the EVEREST II trial. Among them, MR with a large coaptation gap is considered as a challenging anatomy, because the gap makes it difficult to grasp both leaflets with a standard Mitraclip procedure. As two techniques to grasp such a large coaptation gap were reported, there was no report concerning the effectiveness of extracorporeal membrane oxygenation (ECMO) during Mitraclip implantation. Here we present a first case of successful Mitraclip implantation in a patient with a large coaptation gap with the support of ECMO. © 2016 Wiley Periodicals, Inc.


Assuntos
Oxigenação por Membrana Extracorpórea , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
6.
J Endovasc Ther ; 25(5): 542-546, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30056790

RESUMO

Propose: To describe a technique for antegrade cannulation and bridging of the supra-aortic branches through a transapical access in the treatment of an arch aneurysm using combined ascending and branched arch stent-grafts. TECHNIQUE: An 81-year-old man with a past history of open infrarenal aortic repair, emergent endovascular aortic repair for thoracic aortic rupture, and later perivisceral 4-vessel branched endovascular repair of type I thoracoabdominal aneurysm presented for repair of a concomitant 7.5-cm arch aneurysm. Because of a 44-mm ascending aorta, a tapered 50/44-mm ascending stent-graft was delivered through a transapical access to establish an adequate landing zone before implantation of a 46-mm inner branched arch device via a transfemoral route. Innominate and left subclavian arteries were antegradely cannulated and bridged through the existing transapical path. CONCLUSION: Our case demonstrates the feasibility of transapical access for cannulation of an arch branched device, while introducing the theoretical possibility of completing the entire procedure through a transapical access.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Tronco Braquiocefálico , Cateterismo Periférico/métodos , Procedimentos Endovasculares/instrumentação , Stents , Artéria Subclávia , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Tronco Braquiocefálico/diagnóstico por imagem , Evolução Fatal , Humanos , Masculino , Artéria Subclávia/diagnóstico por imagem , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 89(1): E44-E52, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27142257

RESUMO

BACKGROUND: Anemia is linked to impaired outcome in patients with cardiovascular diseases. We sought to characterize the impact of baseline anemia on mid-term outcome after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: Data of 1201 consecutive TAVI patients were retrospectively analyzed. Baseline anemia was defined according to the WHO (hemoglobin <12g/dl [female], <13g/dl [male]). It was prevalent in 59.0% of patients and associated with a higher preoperative risk (STS-PROM 7.8 ± 5.7 vs. 6.2 ± 4.1%, P < 0.001). Survival was similar at 30 days (90.5 vs. 91.2%, P = 0.626) but NYHA functional capacity was impaired in patients with baseline anemia (classes III/IV: 20.6 vs. 15.6%, P = 0.006). Low baseline hemoglobin (OR 0.85, CI 0.73-0.98, P = 0.025), blood transfusion (OR 2.42, CI 1.38-4.28, P = 0.002), and bleeding complications (OR 2.21, CI 1.27-3.81, P = 0.005) were in addition associated with acute kidney injury after TAVI. Three-year survival was reduced (49.6 vs. 64.9%, P = 0.002) and baseline anemia was linked to increased mid-term mortality (HR 1.43, CI 1.13-1.82, P = 0.003), however its effect was surpassed by the adverse impact of periprocedural complications. CONCLUSIONS: Baseline anemia was associated with increased morbidity and mortality after TAVI. Preprocedural hemoglobin levels need to be assessed for risk stratification and blood conservation management seems essential. As a potentially modifiable target, the role of pretreatment of anemia prior to TAVI remains to be determined. © 2016 Wiley Periodicals, Inc.


Assuntos
Anemia/complicações , Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Anemia/sangue , Anemia/diagnóstico , Anemia/mortalidade , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Biomarcadores/sangue , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Feminino , Alemanha , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemoglobinas/metabolismo , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Razão de Chances , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 90(7): 1167-1174, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28296065

RESUMO

OBJECTIVES: The aim of this study was to evaluate safety, feasibility, and efficacy of transaxillary TAVI using a novel self-expandable transcatheter heart valve (THV) via a direct percutaneous technique. METHODS: The analysis comprises 12 consecutive patients with severe aortic stenosis treated with the ACURATE Neo™ THV (Symetis) by direct percutaneous transaxillary access. RESULTS: Patients presented with a mean age of 79.9 ± 6.2 years and high calculated surgical risk (logEuroSCORE I: 19.55 ± 15.00%; STS PROM score: 5.42 ± 3.25%). Transaxillary TAVI was performed in 11/12 via the left and in 1/12 via the right-sided axillary artery. Device success was achieved in all patients (12/12). Mortality rate at 30 days was 0% (0/12). No major and one minor access site complication (1/12) occurred. No major or life-threatening access site-related bleeding resulted. None of the patients suffered from postprocedural stroke/transient ischemic attack. There was no need for a permanent pacemaker. Mean effective orifice area post implantation was 2.1 ± 0.29 cm2 and mean aortic gradient 6.2 ± 1.5 mm Hg. In none of the patients, greater than moderate aortic regurgitation or paravalvular leakage was detected at discharge (0/12). CONCLUSIONS: Our study suggests that the implantation of the second-generation self-expandable ACURATE Neo™ via a transaxillary access is technically feasible and safe and yields excellent short-term clinical results. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Artéria Axilar , Cateterismo Periférico/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Artéria Axilar/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Bases de Dados Factuais , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Falha de Prótese , Punções , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 86(7): 1280-6, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26389782

RESUMO

INTRODUCTION: Implantation of transcatheter heart valves (THV) into degenerated surgical valves is an emerging therapy for selected high-risk patients. Although, CE mark of most THV is limited for native aortic valvular stenosis, transcatheter valve implantation into degenerated bioprostheses, even in mitral position is very intriguing. METHODS AND RESULTS: After placement of a cerebral protection device (Claret Sentinel®), three consecutive patients (age, 79.0 ± 6.1; log EuroSCORE I: 33.3 ± 9.2%) with a degenerated mitral bioprosthesis were treated by transapical implantation of the Lotus® valve (Boston Scientific Inc.). In addition, a SwanGanz catheter was introduced in the pulmonary artery for hemodynamic assessments all patients. Procedural success was 100%. Valve implantation was performed without rapid ventricular pacing. Resheating was performed in two patients due to suboptimal initial positioning. Invasive online hemodynamics revealed stable blood pressure in all patients. After Lotus® valve implantation, valvular mitral regurgitation was completely eliminated in all patients. One patient had a mild paravalvular leak of the surgical bioprosthesis, which was present before implantation. Invasive right and left heart hemodynamics showed an immediate improvement after Lotus® valve implantation. Mean mitral surface area (2.1 ± 0.2 cm(2) ) and mean gradient (3.7 ± 2.1 mm Hg) demonstrated satisfactory results. All patients were immediately extubated and discharged from the hospital without any adverse event. CONCLUSIONS: This study demonstrates for the first time the feasibility of transapical Lotus® Valve implantation in degenerated mitral bioprostheses. The controlled mechanical Lotus® valve expansion with remarkably stable hemodynamics throughout the procedure offers a new and valuable treatment option.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Cateterismo de Swan-Ganz , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Masculino , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Retratamento , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 85(3): 440-7, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24975883

RESUMO

OBJECTIVES: We aimed at identifying predictors of renal impairment and its impact on long-term outcome after transcatheter aortic valve implantation (TAVI). BACKGROUND: Renal impairment is common in mostly elderly, multimorbid patients undergoing TAVI. The risk of periprocedural renal function impairment and its association with outcome is incompletely understood. METHODS: In 458 consecutive patients (mean age, 80.6 ± 7.0 years, 52.2% women) who underwent routine TAVI procedures, we assessed estimated glomerular filtration rate (eGFR) at baseline, during 72-hr postprocedure and at discharge. Over a median follow-up of 0.96 years, we observed 142 deaths. RESULTS: In multivariable-adjusted models, predictors of renal function deterioration within 72 hr were baseline eGFR (ß = 0.83, 95% confidence interval [CI] = 0.76/0.91; P < 0.0001), body mass index (ß = -1.20, 95% CI = 1.77/-0.62; P < 0.0001), and major access site complications (ß = -14.82, 95% CI = -26.52/-3.11; P = 0.013) including bleeding (ß = -11.97, 95% CI = -21.05/-2.89; P = 0.0099). Strongest renal function predictor of 1-year mortality in risk factor adjusted analyses was the change of eGFR within 72 hr (odds ratio, 0.97; 95% CI = 0.96/0.98; P < 0.0001). The addition of information on the change of eGFR increased the C-statistic of the logistic EuroSCORE (P = 0.021). CONCLUSIONS: In our routine TAVI sample, baseline eGFR, body mass index, and major access site complications mainly owing to bleeding were correlates of acute kidney injury after TAVI. Acute renal impairment was a risk factor for mortality and adverse cardiovascular events which provided risk information beyond the EuroSCORE.


Assuntos
Injúria Renal Aguda/mortalidade , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Nefropatias/mortalidade , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Índice de Massa Corporal , Cateterismo Cardíaco/efeitos adversos , Feminino , Taxa de Filtração Glomerular , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/mortalidade , Humanos , Estimativa de Kaplan-Meier , Rim/fisiopatologia , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Modelos Lineares , Masculino , Análise Multivariada , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 85(3): 460-7, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25292388

RESUMO

OBJECTIVES: We sought to evaluate the relationship of blood transfusion after transcatheter aortic valve implantation (TAVI) and mid-term outcome to improve patient selection and periprocedural treatment. BACKGROUND: Increasing evidence suggests a negative influence of blood transfusion on outcomes of patients with cardiovascular diseases. While the adverse impact of bleeding events on survival has been documented after TAVI, data on the impact of postoperative blood transfusions are scarce. METHODS: TAVI was performed in 700 consecutive patients; 14.7% of TAVI patients suffered from bleeding or access site complications and were excluded from analysis to minimize confounding. Outcomes were analyzed with emphasis on blood transfusions and according to the Valve Academic Research Consortium definitions. Median follow-up duration was 364 days. Multivariable analyses were performed to identify predictors for transfusion and 1-year mortality. RESULTS: 33.0% of patients received blood transfusions after TAVI, irrespective of access choice. Blood transfusions were associated with a higher baseline risk profile (median logistic EuroSCORE 21.0 vs. 17.0%), increased rates of postoperative complications and impaired survival (21.2 vs. 36.1% all-cause 1-year mortality). Transfusion was an independent predictor of mortality at 1 year (OR 2.78 [CI 1.59-4.86]). Low body mass index (OR 0.94 [0.89-1.0]), low baseline hemoglobin (OR 0.39 [0.33-0.47]) and combined anticoagulation/antiplatelet therapy were identified as independent predictors of blood transfusion after TAVI. CONCLUSIONS: Blood transfusions were frequently required after TAVI even in the absence of overt bleeding or access site complications and were identified as an independent predictor of impaired mid-term outcome. Optimization of baseline factors, strict blood conservation strategies, and individualized antiplatelet or anticoagulant regimens may improve outcome after TAVI.


Assuntos
Valva Aórtica , Cateterismo Cardíaco/efeitos adversos , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/terapia , Reação Transfusional , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue/mortalidade , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Feminino , Alemanha , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemorragia/diagnóstico , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 84(3): 486-93, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24753352

RESUMO

BACKGROUND: Transcatheter valve-in-valve (VIV) implantation has emerged as a novel treatment option in patients with degenerated aortic bioprostheses and high surgical risk. However, VIV implantation in small aortic bioprostheses using first generation TAVI devices has frequently resulted in high postprocedural gradients and small effective orifice areas. Recently, an updated version of the self-expandable Medtronic CoreValve prosthesis, which is particularly suitable for small aortic annuli, has become available. We report on the feasibility and early results of VIV implantation using this novel device in a series of patients with degenerated small aortic bioprostheses. METHODS AND RESULTS: 16 patients from two Hamburg hospitals (age range 72-92 years) underwent implantation of a 23-mm CoreValve Evolut (Medtronic, Minneapolis, MN, USA) transcatheter heart valve into failing aortic bioprostheses with internal diameters below 21 mm. All patients were considered high risk for surgical aortic valve replacement after evaluation by an interdisciplinary heart team mean (logistic EuroSCORE range 9.0-88%). Implantation was successful without relevant remaining aortic regurgitation or signs of stenosis and a marked reduction in postprocedural gradientswas observed in 14 out of 16 patients. The mean gradient was reduced from from 34 mm Hg (SEM 10 mm Hg) to 14 mm Hg (SEM 6 mm Hg). No major device- or procedure-related adverse events occurred during 30-day follow up and clinical improvement was observed. CONCLUSIONS: Failing aortic bioprostheses with small internal diameters continue to be a challenging pathology for TAVI due to the risk of high residual gradients and small aortic orifice areas. This report provides first evidence that the 23-mm CoreValve Evolut, a novel self-expanding prosthesis, provides an improved treatment option in these specific patients due to its low profile which resulted in promising early results. © 2013 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Thorac Cardiovasc Surg ; 62(6): 498-502, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24911901

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become routine for the treatment of high-risk patients with aortic stenosis. We assessed safety and feasibility of a left ventricular apical access and closure device combined with second-generation transapical (TA) TAVI transcatheter heart valves (THV). METHODS AND RESULTS: Three elderly, comorbid patients (logEuroSCORE I 13.0-31.1%) received transapical aortic valve implantation (TA-AVI) via the Apica ASC device (Apica Cardiovascular Ltd., Galway, Ireland) using second-generation THV (Medtronic Engager [Medtronic 3F Therapeutics, Santa Ana, California, United States], JenaValve [JenaValve Technology GmbH, Munich, Germany], Symetis Acurate [Symetis S.A., Ecublens, Switzerland]). Access was gained using a non-rib-spreading technique and a novel access and closure device. THV deployment was successful with excellent hemodynamic outcome (no PVL, n = 2; trace PVL, n = 1; mean transvalvular gradients, 5-19 mm Hg) and complete apical hemostasis. No periprocedural major adverse events occurred and Valve Academic Research Consortium-2-defined composite end point of device success was met in all cases. CONCLUSION: Safety and feasibility of TA-AVI using the ASC device with second-generation THV was demonstrated. Combining latest available technology is a major step toward improved functional outcome and decreased surgical trauma in TA-AVI. Potentially, technical enhancements may eventually pave the way toward a fully percutaneous TA-AVI procedure.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Punções , Índice de Gravidade de Doença , Resultado do Tratamento
14.
Clin Res Cardiol ; 113(1): 18-28, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37017780

RESUMO

AIMS: This study was performed to compare haemodynamic properties of a novel transcatheter heart valve (THV) with two established valve technologies for treatment of failing surgical aortic bioprosthetic valves (SAV). The ALLEGRA THV has been recently described with a proven safety and performance profile. METHODS AND RESULTS: The study was designed as a retrospective, single-centre study investigating 112 patients (77.7 ± 7.1 years, 53.8% female, STS score 6.8 ± 5.8% and logEuroSCORE I 27.4 ± 16.1%) with failing SAV. Patients were treated with the ALLEGRA THV (NVT, n = 24), the CoreValve/EvolutR (MTD, n = 64) or the Edwards Sapien/Sapien XT/Sapien 3 (EDW, n = 24). Adverse events, haemodynamic outcomes and patient safety were analysed according to VARC-3 definitions. Overall procedural success was high (94.6%), even though 58.9% of the treated SAV were classified as small (true inner diameter < 21 mm). After treatment, the mean pressure gradient was significantly reduced (baseline: 33.7 ± 16.5 mmHg, discharge: 18.0 ± 7.1 mmHg), with a corresponding increase in effective orifice area (EOA). The complication rates did not differ in between groups. There was a trend to lower mean transvalvular gradients after implantation of self-expanding THV with supra-annular valve function, despite a higher frequency of smaller SAVs in the NVT and MTD group. Additionally, comparison between NVT and MTD revealed statistically lower transvalvular gradients (NVT 14.9 ± 5.0 mmHg, MTD 18.7 ± 7.5 mmHg, p = 0.0295) in a subgroup analysis. CONCLUSIONS: Valve-in-valve (ViV) treatment of failing SAV with supra-annular design like the ALLEGRA THV resulted in favourable haemodynamic outcomes with similar low clinical event rates and may therefore be an interesting alternative for VIV TAVI.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Terfenadina/análogos & derivados , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese
15.
J Clin Med ; 13(5)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38592323

RESUMO

(1) Background: Transfemoral transcatheter aortic valve implantation (TAVI) has become the standard treatment for most patients with severe symptomatic aortic stenosis. Intravascular lithotripsy may facilitate transfemoral TAVI (IVL-TAVI) even in patients with severely calcified iliofemoral disease. We assessed technical aspects and clinical outcomes of this novel approach compared to alternative transaxillary access (TAX-TAVI). (2) Methods: IVL-TAVI was performed for severe iliofemoral calcifications precluding standard transfemoral access in 30 patients from 2019 to 2022 at a single academic heart center. IVL was performed as part of the TAVI procedure in all cases. Results were compared to a control group of 44 TAX-TAVI procedures performed for the same indication from 2016 to 2021. The safety outcome was a composite of all-cause death, stroke, access-related bleeding ≥ type 2 within 24 h and major vascular access site complications at 30 days. The efficacy outcome was defined as a technical success according to VARC-3. (3) Results: Median age was 78.2 [74.3, 82.6] years, 45.9% were female and mean STS-PROM was 3.6% [2.3, 6.0]. Iliofemoral calcifications were more severe in the IVL-TAVI vs. TAX-TAVI groups (lesion length: 63.0 mm [48.6, 80.3] vs. 48.5 mm [33.1, 68.8]; p = 0.043, severe calcification at target lesion: 90.0% vs. 68.2%; p = 0.047, and median arc calcification 360.0° [297.5, 360.0] vs. 360.0° [180.0, 360.0]; p = 0.033). Technical success was achieved in 93.3% vs. 81.8% (p = 0.187) in IVL- and TAX-TAVI and the safety outcome occurred in 10.0% vs. 31.8% in IVL- and TAX-TAVI (p = 0.047), respectively. (4) Conclusions: IVL-assisted transfemoral TAVI was feasible and safe with favorable outcomes compared to TAX-TAVI. IVL may further expand the number of patients eligible for transfemoral TAVI and may help overcome limitations of an alternative access.

16.
Clin Res Cardiol ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466346

RESUMO

BACKGROUND: Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS: This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS: Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS: Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION: Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.

17.
Catheter Cardiovasc Interv ; 82(4): 640-52, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23172652

RESUMO

OBJECTIVES: We report the results of a large single-center study evaluating predictors and outcomes after transcatheter aortic valve implantation (TAVI) with different devices and access routes according to the Valve Academic Research Consortium (VARC). BACKGROUND: The widespread adoption of TAVI warrants a systematic analysis of outcomes. Only few comprehensive data exist comparing different approaches as selected by a heart team. METHODS: TAVI was performed in 326 consecutive patients (mean age 80.6 ± 7.1 years, 55.5% female) at high risk for surgery with balloon-expandable and self-expanding devices through transfemoral or transapical access. Data were analyzed according to VARC endpoints; predictors of mortality were identified. RESULTS: All-cause mortality was 10.1% (30 days) and 29.9% (1 year) overall and comparable with regard to valve or access choice (P = 0.295) despite different risk profiles at baseline. Device success and 30-day safety endpoints were achieved in 87.1 and 21.2%. Myocardial infarction [hazard ratio (HR) 6.52], stage-2 and -3 acute kidney injury (HR 2.52 and 6.80) and major access site complications (HR 1.96) were independent predictors of 1-year all-cause mortality. Device success had a protective effect (HR 0.58). Baseline predictors included body mass index <20 kg/m(2) (HR 3.20), NYHA class IV (HR 1.87), left ventricular ejection-fraction <30% (HR 2.30), higher STS-PROM scores (HR 1.05 per percent), and age (group 75-85 years, HR 0.47). CONCLUSIONS: Comparable results were achieved with different devices and access routes in a heart team approach. Baseline and perioperative predictors of all-cause mortality were identified, contributing to the refinement of patient and device selection criteria for TAVI.


Assuntos
Valva Aórtica , Cateterismo Cardíaco , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Injúria Renal Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Competência Clínica , Feminino , Alemanha , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Curva de Aprendizado , Masculino , Análise Multivariada , Infarto do Miocárdio/mortalidade , Seleção de Pacientes , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
18.
J Heart Valve Dis ; 22(6): 789-93, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24597399

RESUMO

BACKGROUND AND AIM OF THE STUDY: Female gender has recently been suggested to predict a beneficial outcome and lower mortality following transcatheter aortic valve implantation (TAVI). The study aim was to address gender differences in outcome following TAVI and potentially to replicate these findings. METHODS: The present single-center prospective registry of 326 patients with severe aortic stenosis treated by TAVI between 2008 and 2011 consisted of 181 women and 145 men. RESULTS: The procedural risk was not significantly different between men and women at baseline. For all-cause mortality no difference was observed at 30 days and at 12 months after TAVI. CONCLUSION: While several baseline characteristics between men and women treated by TAVI were shown to be different among the study population, no difference was observed in survival between both genders.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Resultado do Tratamento
19.
Thorac Cardiovasc Surg ; 61(5): 421-4, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22383150

RESUMO

For elderly patients with relevant comorbidities, combined cardiac surgery may be inadequate due to excessive surgical risk. Combining interventional valvular and surgical approaches may decrease surgical burden and operative risk. In the present case, we report a staged strategy of interventional mitral valve repair and secondary surgical aortic valve replacement and replacement of the ascending aorta in a patient at high risk for surgery. This hybrid approach allowed for substitution of one part of surgery by the relatively low-risk MitraClip procedure. For the future, increasing clinical importance of interventional valve therapies either for stand-alone or hybrid procedures can be anticipated.


Assuntos
Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral/cirurgia , Idoso de 80 Anos ou mais , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Aortografia/métodos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ecocardiografia Doppler em Cores , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Dispositivos de Fixação Cirúrgica , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
Clin Res Cardiol ; 112(5): 691-701, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36792752

RESUMO

BACKGROUND: Beneficial results of transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) in patients at all risk strata have led to substantial changes in guideline recommendations for valvular heart disease. AIM: To examine influence of these guideline changes on a real-world TAVI cohort, we evaluated how risk profiles and outcomes of TAVI patients developed in our single-center patient cohort over a period of 12 years. METHODS: Baseline, procedural and 30-day outcome parameters of TAVI patients were retrospectively compared between three time periods (period 1: 2008-2012, period 2: 2013-2017, period 3: 2018-2020). RESULTS: Between 03/2008 and 12/2020, a total of 3678 patients underwent TAVI at our center. The median age was 81.1 years (25th, 75th percentile: 76.7, 84.9) with no significant change over time. The EuroSCORE II showed a continuous and significant decline from 5.3% (3.3, 8.6) in period 1 to 2.8% (1.7, 5.0) in period 3 (p < 0.001). Furthermore, rates of permanent pacemaker implantation, acute kidney injury, and paravalvular leakage ≥ moderate continuously declined over time. Accordingly, the 30-day mortality fell from 9.3% in period 1 to 4.3% in period 3 (p < 0.001). CONCLUSION: Despite substantial guideline alterations, median patient age remained largely unchanged in our TAVI cohort over the past 12 years. Therefore, increased age still appears to be the main reason to choose TAVI over SAVR. However, risk profiles declined substantially. Significant improvements in early outcomes suggest favorable influence of less invasive access routes, improved device platforms and growing user experience.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Criança , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA