Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Philos Trans A Math Phys Eng Sci ; 381(2244): 20220025, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-36774952

RESUMO

Collapse of lipidic ultrasound contrast agents under high-frequency compressive load has been historically interpreted by the vanishing of surface tension. By contrast, buckling of elastic shells is known to occur when costly compressible stress is released through bending. Through quasi-static compression experiments on lipidic shells, we analyse the buckling events in the framework of classical elastic buckling theory and deduce the mechanical characteristics of these shells. They are then compared with that obtained through acoustic characterization. This article is part of the theme issue 'Probing and dynamics of shock sensitive shells'.

2.
Proc Natl Acad Sci U S A ; 117(29): 16756-16763, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32616571

RESUMO

The evaporation of suspension droplets is the underlying mechanism in many surface-coating and surface-patterning applications. However, the uniformity of the final deposit suffers from the coffee-stain effect caused by contact line pinning. Here, we show that control over particle deposition can be achieved through droplet evaporation on oil-wetted hydrophilic surfaces. We demonstrate by flow visualization, theory, and numerics that the final deposit of the particles is governed by the coupling of the flow field in the evaporating droplet, the movement of its contact line, and the wetting state of the thin film surrounding the droplet. We show that the dynamics of the contact line can be tuned through the addition of a surfactant, thereby controlling the surface energies, which then leads to control over the final particle deposit. We also obtain an analytical expression for the radial velocity profile which reflects the hindering of the evaporation at the rim of the droplet by the nonvolatile oil meniscus, preventing flow toward the contact line, thus suppressing the coffee-stain effect. Finally, we confirm our physical interpretation by numerical simulations that are in qualitative agreement with the experiment.

3.
J Acoust Soc Am ; 151(4): 2545, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35461477

RESUMO

Microbubbles entrained in a piezo-driven drop-on-demand printhead disturb the acoustics of the microfluidic ink channel and, thereby, the jetting behavior. Here, the resonance behavior of an ink channel as a function of the microbubble size and number of bubbles is studied through theoretical modeling and experiments. The system is modeled as a set of two coupled harmonic oscillators: one corresponds to the compliant ink channel and the other corresponds to the microbubble. The predicted and measured eigenfrequencies are in excellent agreement. It was found that the resonance frequency is independent of the bubble size as long as the compliance of the bubble dominates over that of the piezo actuator. An accurate description of the eigenfrequency of the coupled system requires the inclusion of the increased inertance of the entrained microbubble due to confinement. It is shown that the inertance of a confined bubble can be accurately obtained by using a simple potential flow approach. The model is further validated by the excellent agreement between the modeled and measured microbubble resonance curves. The present work, therefore, provides physical insight into the coupled dynamics of a compliant ink channel with an entrained microbubble.

4.
J Acoust Soc Am ; 151(6): 3993, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35778226

RESUMO

Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 µm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera" (AC). The AC measures the relative microbubble oscillation while the optical camera measures the absolute oscillation. In this article, the capabilities of the AC are extended to measure the absolute oscillations. In the AC setup, microbubbles are insonified with a high- (25 MHz) and low-frequency US wave (1-2.5 MHz). Other than the amplitude modulation (AM) from the relative size change of the microbubble (employed in Renaud, Bosch, van der Steen, and de Jong (2012a). "An 'acoustical camera' for in vitro characterization of contrast agent microbubble vibrations," Appl. Phys. Lett. 100(10), 101911, the high-frequency response from individual vibrating microbubbles contains a phase modulation (PM) from the microbubble wall displacement, which is the extension described here. The ratio of PM and AM is used to determine the absolute radius, R0. To test this sizing, the size distributions of two monodisperse microbubble populations ( R = 2.1 and 3.5 µm) acquired with the AC were matched to the distribution acquired with a Coulter counter. As a result of measuring the absolute size of the microbubbles, this "extended AC" can capture the full radial dynamics of single freely floating microbubbles with a throughput of hundreds of microbubbles per hour.


Assuntos
Microbolhas , Rádio (Anatomia) , Meios de Contraste , Ultrassonografia
5.
Phys Rev Lett ; 126(3): 034501, 2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33543968

RESUMO

Vaporization of low-boiling point droplets has numerous applications in combustion, process engineering, and in recent years, in clinical medicine. However, the physical mechanisms governing the phase conversion are only partly explained. Here, we show that an acoustic resonance can arise from the large speed of sound mismatch between a perfluorocarbon microdroplet and its surroundings. The fundamental resonance mode obeys a unique relationship kR∼0.65 between droplet size and driving frequency that leads to a threefold pressure amplification inside the droplet. Classical nucleation theory shows that this pressure amplification increases the nucleation rate by several orders of magnitude. These findings are confirmed by high-speed imaging performed at a timescale of 10 ns. The optical recordings demonstrate that droplets exposed to intense acoustic waves generated by interdigital transducers nucleate only if they match the theoretical resonance size.

6.
Langmuir ; 37(12): 3605-3611, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33734702

RESUMO

The wetting properties of multicomponent liquids are crucial to numerous industrial applications. The mechanisms that determine the contact angles for such liquids remain poorly understood, with many intricacies arising due to complex physical phenomena, for example, due to the presence of surfactants. Here, we consider two-component drops that consist of mixtures of vicinal alkanediols and water. These diols behave surfactant-like in water. However, the contact angles of such mixtures on solid substrates are surprisingly large. We experimentally reveal that the contact angle is determined by two separate mechanisms of completely different nature, namely, Marangoni contraction (hydrodynamic) and autophobing (molecular). The competition between these effects can even inhibit Marangoni contraction, highlighting the importance of molecular structures in physico-chemical hydrodynamics.

7.
Langmuir ; 35(32): 10453-10460, 2019 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-31291117

RESUMO

Evaporation of surfactant-laden sessile droplets is omnipresent in nature and industrial applications such as inkjet printing. Soluble surfactants start to form micelles in an aqueous solution for surfactant concentrations exceeding the critical micelle concentration (CMC). Here, the evaporation of aqueous sodium dodecyl sulfate (SDS) sessile droplets on hydrophobic surfaces was experimentally investigated for SDS concentrations ranging from 0.025 to 1 CMC. In contrast to the constant contact angle of an evaporating sessile water droplet, we observed that, at the same surface, the contact angle of an SDS laden droplet with concentration below 0.5 CMC first decreases, then increases, and finally decreases, resulting in a local contact angle minimum. Surprisingly, the minimum contact angle was found to be substantially lower than the static receding contact angle and decreased with decreasing initial SDS concentration. Furthermore, the bulk SDS concentration at the local contact angle minimum was found to decrease with decrease in the initial SDS concentration. The location of the observed contact angle minimum relative to the normalized evaporation time and its minimum value proved to be independent of both the relative humidity and droplet volume and thus of the total evaporation time. We discuss the observed contact angle dynamics in terms of the formation of a disordered layer of SDS molecules on the substrate at concentrations below 0.5 CMC. The present work underlines the complexity of the evaporation of sessile liquid-surfactant droplets and the influence of surfactant-substrate interactions on the evaporation process.

8.
Langmuir ; 35(31): 10173-10191, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-30653325

RESUMO

In the last couple of decades, ultrasound-driven microbubbles have proven excellent candidates for local drug delivery applications. Besides being useful drug carriers, microbubbles have demonstrated the ability to enhance cell and tissue permeability and, as a consequence, drug uptake herein. Notwithstanding the large amount of evidence for their therapeutic efficacy, open issues remain. Because of the vast number of ultrasound- and microbubble-related parameters that can be altered and the variability in different models, the translation from basic research to (pre)clinical studies has been hindered. This review aims at connecting the knowledge gained from fundamental microbubble studies to the therapeutic efficacy seen in in vitro and in vivo studies, with an emphasis on a better understanding of the response of a microbubble upon exposure to ultrasound and its interaction with cells and tissues. More specifically, we address the acoustic settings and microbubble-related parameters (i.e., bubble size and physicochemistry of the bubble shell) that play a key role in microbubble-cell interactions and in the associated therapeutic outcome. Additionally, new techniques that may provide additional control over the treatment, such as monodisperse microbubble formulations, tunable ultrasound scanners, and cavitation detection techniques, are discussed. An in-depth understanding of the aspects presented in this work could eventually lead the way to more efficient and tailored microbubble-assisted ultrasound therapy in the future.


Assuntos
Portadores de Fármacos/química , Microbolhas , Animais , Membrana Celular/metabolismo , Permeabilidade da Membrana Celular , Humanos , Farmacocinética , Terapia por Ultrassom/métodos , Ondas Ultrassônicas , Ultrassom/métodos
9.
Soft Matter ; 14(47): 9550-9561, 2018 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-30357244

RESUMO

The acoustic response of phospholipid-coated microbubble ultrasound contrast agents (UCA) is dramatically affected by their stabilizing shell. The interfacial shell elasticity increases the resonance frequency, the shell viscosity increases damping, and the nonlinear shell viscoelasticity increases the generation of harmonic echoes that are routinely used in contrast-enhanced ultrasound imaging. To date, the surface area-dependent interfacial properties of the phospholipid coating have never been measured due to the extremely short time scales of the MHz frequencies at which the microscopic bubbles are driven. Here, we present high-precision acoustic measurements of the dilatational nonlinear viscoelastic shell properties of phospholipid-coated microbubbles. These highly accurate measurements are now accessible for the first time by tuning the surface dilatation, that is, the lipid packing density, of well-controlled monodisperse bubble suspensions through the ambient pressure. Upon compression, the shell elasticity of bubbles coated with DPPC and DPPE-PEG5000 was found to increase up to an elasticity of 0.6 N m-1 after which the monolayer collapses and the elasticity vanishes. During bubble expansion, the elasticity drops monotonically in two stages, first to an elasticity of 0.35 N m-1, and then more rapidly to zero. Integration of the elasticity vs. surface area curves showed that, indeed, a phospholipid-coated microbubble is in a tensionless state upon compression, and that it reaches the interfacial tension of the surrounding medium upon expansion. The measurements presented in this work reveal the detailed features of the nonlinear dilatational shell behavior of micron-sized lipid-coated bubbles.

10.
Perfusion ; 33(1): 16-24, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28766987

RESUMO

INTRODUCTION: Gaseous microemboli (GME) introduced during cardiac surgery are considered as a potential source of morbidity, which has driven the development of the first bubble counters. Two new generation bubble counters, introduced in the early 2000s, claim correct sizing and counting of GME. This in-vitro study aims to validate the accuracy of two bubble counters using monodisperse bubbles in a highly controlled setting at low GME concentrations. METHODS: Monodisperse GME with a radius of 43 µm were produced in a microfluidic chip. Directly after their formation, they were injected one-by-one into the BCC200 and the EDAC sensors. GME size and count, measured with the bubble counters, were optically verified using high-speed imaging. RESULTS: During best-case scenarios or low GME concentrations of GME with a size of 43 µm in radius in an in-vitro setup, the BCC200 overestimates GME size by a factor of 2 to 3 while the EDAC underestimates the average GME size by at least a factor of two. The BCC200 overestimates the GME concentration by approximately 20% while the EDAC overestimates the concentration by nearly one order of magnitude. Nevertheless, the calculated total GME volume is only over-predicted by a factor 2 since the EDAC underestimates the actual GME size. For the BCC200, the total GME volume was over-predicted by 25 times due to the over-estimation of GME size. CONCLUSIONS: The measured errors in the absolute sizing/counting of GME do not imply that all results obtained using the bubble counters are insignificant or invalid. A relative change in bubble size or bubble concentration can accurately be measured. However, care must be taken in the interpretation of the results and their absolute values. Moreover, the devices cannot be used interchangeably when reporting GME activity. Nevertheless, both devices can be used to study the relative air removal characteristics of CPB components or for the quantitative monitoring of GME production during CPB interventions.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/métodos , Embolia Aérea/etiologia , Desenho de Equipamento/métodos , Humanos
11.
Langmuir ; 33(39): 10329-10339, 2017 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-28872315

RESUMO

Resonantly driven monodisperse phospholipid-coated microbubbles are expected to substantially increase the sensitivity and efficiency in contrast-enhanced ultrasound imaging and therapy. They can be produced in a microfluidic flow-focusing device, but questions remain as to the role of the device geometry, the liquid and gas flow, and the phospholipid formulation on bubble stability. Here, we develop a model based on simple continuum mechanics equations that reveals the scaling of the coalescence probability with the key physical parameters. It is used to characterize short-term coalescence behavior and long-term size stability as a function of flow-focusing geometry, bulk viscosity, lipid cosolvent mass fraction, lipid concentration, lipopolymer molecular weight, and lipopolymer molar fraction. All collected data collapse on two master curves given by universal equations for the coalescence probability and the long-term size stability. This work is therefore a route to a more fundamental understanding of the physicochemical monolayer properties of microfluidically formed bubbles and their coalescence behavior in a flow-focusing device.

12.
Langmuir ; 32(16): 3937-44, 2016 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-27006083

RESUMO

Monodisperse microbubble ultrasound contrast agents may dramatically increase the sensitivity and efficiency in ultrasound imaging and therapy. They can be produced directly in a microfluidic flow-focusing device, but questions remain as to the interfacial chemistry, such as the formation and development of the phospholipid monolayer coating over time. Here, we demonstrate the synthesis of monodisperse bubbles with radii of 2-10 µm at production rates ranging from 10(4) to 10(6) bubbles/s. All bubbles were found to dissolve to a stable final radius 2.55 times smaller than their initial radius, independent of the nozzle size and shear rate, indicating that the monolayer self-assembles prior to leaving the nozzle. The corresponding decrease in surface area by a factor 6.6 reveals that lipid molecules are adsorbed to the gas-liquid interface in the disordered expanded state, and they become mechanically compressed by Laplace pressure-driven bubble dissolution to a more ordered condensed state with near zero surface tension. Acoustic characterization of the stabilized microbubbles revealed that their shell stiffness gradually increased from 0.8 to 2.5 N/m with increasing number of insonations through the selective loss of the more soluble lipopolymer molecules. This work therefore demonstrates high-throughput production of clinically relevant monodisperse contrast microbubbles with excellent control over phospholipid monolayer elasticity and microbubble resonance.

13.
J Acoust Soc Am ; 140(4): 2506, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27794344

RESUMO

The sensitivity and efficiency in contrast-enhanced ultrasound imaging and therapy can potentially be increased by the use of resonant monodisperse bubbles. However, bubbles of the same size may respond differently to ultrasound due to differences in their phospholipid shell. In an acoustic bubble sorting chip, resonant bubbles can be separated from the polydisperse agent. Here, a sample of acoustically sorted bubbles is characterized by measuring scattering and attenuation simultaneously using narrowband acoustic pulses at peak negative pressures of 10, 25, and 50 kPa over a 0.7-5.5 MHz frequency range. A second sample is characterized by attenuation measurements at acoustic pressures ranging from 5 to 75 kPa in steps of 2.5 kPa. Scattering and attenuation coefficients were modeled by integration over the pressure and frequency dependent response of all bubbles located within the non-uniform acoustic characterization beam. For all driving pressures and frequencies employed here, the coefficients could be modeled using a single and unique set of shell parameters confirming that acoustically sorted bubbles provide a uniform acoustic response. Moreover, it is shown that it is crucial to include the pressure distribution of the acoustic characterization beam in the modeling to accurately determine shell parameters of non-linearly oscillating bubbles.

14.
J Colloid Interface Sci ; 673: 788-796, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38906000

RESUMO

HYPOTHESIS: Electrostatically stabilised colloidal particles destabilise when brought into contact with cations causing the particles to aggregate in clusters. When a drop with stabilised colloidal partices is deposited on a liquid film containing cations the delicate balance between the fluid-mechanical and physicochemical properties of the system governs the spreading dynamics and formation of colloidal particle clusters. EXPERIMENTS: High-speed imaging and digital holographic microscopy were used to characterise the spreading process. FINDINGS: We reveal that a spreading colloidal drop evolves into a ring-shaped pattern after it is deposited on a thin saline water film. Clustered colloidal particles aggregate into larger trapezoidally-shaped 'supraclusters'. Using a simple model we show that the trapezoidal shape of the supraclusters is determined by the transition from inertial spreading dynamics to Marangoni flow. These results may be of interest to applications such as wet-on-wet inkjet printing, where particle destabilisation and hydrodynamic flow coexist.

15.
Ultrasound Med Biol ; 50(8): 1099-1107, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38851940

RESUMO

OBJECTIVE: Ultrasound-triggered bubble-mediated local drug delivery has shown potential to increase therapeutic efficacy and reduce systemic side effects, by loading drugs into the microbubble shell and triggering delivery of the payload on demand using ultrasound. Understanding the behavior of the microbubbles in response to ultrasound is crucial for efficient and controlled release. METHODS: In this work, the response of microbubbles with a coating consisting of poly(2-ethyl-butyl cyanoacrylate) (PEBCA) nanoparticles and denatured casein was characterized. High-speed recordings were taken of single microbubbles, in both bright field and fluorescence. RESULTS: The nanoparticle-loaded microbubbles show resonance behavior, but with a large variation in response, revealing a substantial interbubble variation in mechanical shell properties. The probability of shell rupture and the probability of nanoparticle release were found to strongly depend on microbubble size, and the most effective size was inversely proportional to the driving frequency. The probabilities of both rupture and release increased with increasing driving pressure amplitude. Rupture of the microbubble shell occurred after fewer cycles of ultrasound as the driving pressure amplitude or driving frequency was increased. CONCLUSION: The results highlight the importance of careful selection of the driving frequency, driving pressure amplitude and duration of ultrasound to achieve the most efficient ultrasound-triggered shell rupture and nanoparticle release of protein-and-nanoparticle-stabilized microbubbles.


Assuntos
Sistemas de Liberação de Medicamentos , Microbolhas , Nanopartículas , Nanopartículas/química , Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos , Embucrilato/química , Caseínas/química , Proteínas/química
16.
J Control Release ; 363: 747-755, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37778466

RESUMO

Sonoporation is the process where intracellular drug delivery is facilitated by ultrasound-driven microbubble oscillations. Several mechanisms have been proposed to relate microbubble dynamics to sonoporation including shear and normal stress. The present work aims to gain insight into the role of microbubble size on sonoporation and thereby into the relevant mechanism(s) of sonoporation. To this end, we measured the sonoporation efficiency while varying microbubble size using monodisperse microbubble suspensions. Sonoporation experiments were performed in vitro on cell monolayers using a single ultrasound pulse with a fixed frequency of 1 MHz while the acoustic pressure amplitude and pulse length were varied at 250, 500, and 750 kPa, and 10, 100, and 1000 cycles, respectively. Sonoporation efficiency was quantified using flow cytometry by measuring the FITC-dextran (4 kDa and 2 MDa) fluorescence intensity in 10,000 cells per experiment to average out inherent variations in the bioresponse. Using ultra-high-speed imaging at 10 million frames per second, we demonstrate that the bubble oscillation amplitude is nearly independent of the equilibrium bubble radius at acoustic pressure amplitudes that induce sonoporation (≥ 500 kPa). However, we show that sonoporation efficiency is strongly dependent on the equilibrium bubble size and that under all explored driving conditions most efficiently induced by bubbles with a radius of 4.7 µm. Polydisperse microbubbles with a typical ultrasound contrast agent size distribution perform almost an order of magnitude lower in terms of sonoporation efficiency than the 4.7-µm bubbles. We elucidate that for our system shear stress is highly unlikely the mechanism of action. By contrast, we show that sonoporation efficiency correlates well with an estimate of the bubble-induced normal stress.


Assuntos
Sistemas de Liberação de Medicamentos , Microbolhas , Sistemas de Liberação de Medicamentos/métodos , Ultrassonografia/métodos , Meios de Contraste , Acústica
17.
Rev Sci Instrum ; 92(3): 035110, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820052

RESUMO

Monodisperse lipid-coated microbubbles are a promising route to unlock the full potential of ultrasound contrast agents for medical diagnosis and therapy. Here, we present a stand-alone lab-on-a-chip instrument that allows microbubbles to be formed with high monodispersity at high production rates. Key to maintaining a long-term stable, controlled, and safe operation of the microfluidic device with full control over the output size distribution is an optical transmission-based measurement technique that provides real-time information on the production rate and bubble size. We feed the data into a feedback loop and demonstrate that this system can control the on-chip bubble radius (2.5 µm-20 µm) and the production rate up to 106 bubbles/s. The freshly formed phospholipid-coated bubbles stabilize after their formation to a size approximately two times smaller than their initial on-chip bubble size without loss of monodispersity. The feedback control technique allows for full control over the size distribution of the agent and can aid the development of microfluidic platforms operated by non-specialist end users.

18.
J Vis Exp ; (172)2021 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-34180885

RESUMO

Microbubble contrast agents hold great promise for drug delivery applications with ultrasound. Encapsulating drugs in nanoparticles reduces systemic toxicity and increases circulation time of the drugs. In a novel approach to microbubble-assisted drug delivery, nanoparticles are incorporated in or on microbubble shells, enabling local and triggered release of the nanoparticle payload with ultrasound. A thorough understanding of the release mechanisms within the vast ultrasound parameter space is crucial for efficient and controlled release. This set of presented protocols is applicable to microbubbles with a shell containing a fluorescent label. Here, the focus is on microbubbles loaded with poly(2-ethyl-butyl cyanoacrylate) polymeric nanoparticles, doped with a modified Nile Red dye. The particles are fixed within a denatured casein shell. The microbubbles are produced by vigorous stirring, forming a dispersion of perfluoropropane gas in the liquid phase containing casein and nanoparticles, after which the microbubble shell self-assembles. A variety of microscopy techniques are needed to characterize the nanoparticle-stabilized microbubbles at all relevant timescales of the nanoparticle release process. Fluorescence of the nanoparticles enables confocal imaging of single microbubbles, revealing the particle distribution within the shell. In vitro ultra-high-speed imaging using bright-field microscopy at 10 million frames per second provides insight into the bubble dynamics in response to ultrasound insonation. Finally, nanoparticle release from the bubble shell is best visualized by means of fluorescence microscopy, performed at 500,000 frames per second. To characterize drug delivery in vivo, the triggered release of nanoparticles within the vasculature and their extravasation beyond the endothelial layer is studied using intravital microscopy in tumors implanted in dorsal skinfold window chambers, over a timescale of several minutes. The combination of these complementary characterization techniques provides unique insight into the behavior of microbubbles and their payload release at a range of time and length scales, both in vitro and in vivo.


Assuntos
Microbolhas , Nanopartículas , Meios de Contraste , Sistemas de Liberação de Medicamentos , Liberação Controlada de Fármacos , Microscopia
19.
Ultrasound Med Biol ; 46(4): 892-908, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31941587

RESUMO

Initial reports from the 1960s describing the observations of ultrasound contrast enhancement by tiny gaseous bubbles during echocardiographic examinations prompted the development of the first ultrasound contrast agent in the 1980s. Current commercial contrast agents for echography, such as Definity, Optison, Sonazoid and SonoVue, have proven to be successful in a variety of on- and off-label clinical indications. Whereas contrast-specific technology has seen dramatic progress after the introduction of the first approved agents in the 1990s, successful clinical translation of new developments has been limited during the same period, while understanding of microbubble physical, chemical and biologic behavior has improved substantially. It is expected that for a successful development of future opportunities, such as ultrasound molecular imaging and therapeutic applications using microbubbles, new creative developments in microbubble engineering and production dedicated to further optimizing microbubble performance are required, and that they cannot rely on bubble technology developed more than 3 decades ago.


Assuntos
Meios de Contraste , Ultrassonografia , Albuminas/história , Albuminas/uso terapêutico , Meios de Contraste/história , Meios de Contraste/uso terapêutico , Compostos Férricos/história , Compostos Férricos/uso terapêutico , Fluorocarbonos/história , Fluorocarbonos/uso terapêutico , Previsões , História do Século XX , História do Século XXI , Humanos , Ferro/história , Ferro/uso terapêutico , Óxidos/história , Óxidos/uso terapêutico , Ultrassonografia/história , Ultrassonografia/métodos , Ultrassonografia/tendências
20.
Ultrasound Med Biol ; 46(9): 2117-2144, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32546411

RESUMO

Ultrasound is extensively used in medical imaging, being safe and inexpensive and operating in real time. Its scope of applications has been widely broadened by the use of ultrasound contrast agents (UCAs) in the form of microscopic bubbles coated by a biocompatible shell. Their increased use has motivated a large amount of research to understand and characterize their physical properties as well as their interaction with the ultrasound field and their surrounding environment. Here we review the theoretical models that have been proposed to study and predict the behavior of UCAs. We begin with a brief introduction on the development of UCAs. We then present the basics of free-gas-bubble dynamics upon which UCA modeling is based. We review extensively the linear and non-linear models for shell elasticity and viscosity and present models for non-spherical and asymmetric bubble oscillations, especially in the presence of surrounding walls or tissue. Then, higher-order effects such as microstreaming, shedding and acoustic radiation forces are considered. We conclude this review with promising directions for the modeling and development of novel agents.


Assuntos
Meios de Contraste , Modelos Teóricos , Ultrassonografia/métodos , Fenômenos Físicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA