Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Med Virol ; 96(2): e29431, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38293752

RESUMO

The aim of the study was to determine the presence of human papillomavirus (HPV) in patients with intractable plantar keratosis (IPK) by comparing the histopathological findings of biopsies. A prospective, observational, and concordance study was carried out. Three different specimens were taken from each IPK. A first punch was sent for histopathological examination, and a second punch and a superficial skin scraping were both sent for HPV  polymerase chain reaction (PCR) and type determination. A total of 51 patients were included. From the histopathological examination, it was determined that 35 (68.6%) samples were diagnosed as warts and 16 (31.3%) as keratosis. However, the presence of HPV was confirmed by PCR in 49 (96.1%) and in 42 (82.4%) samples obtained by punch and superficial scraping, respectively. In the 49 PCR-positive samples, the most common HPV types were HPV1, HPV2, HPV27, HPV57, and HPV65, accounting for 81.6% of the samples. In conclusion, this study demonstrates that HPV infection and IPK lesions are very closely related. Although we cannot confirm that HPV is the cause of the development of IPK, the high prevalence of HPV observed in these lesions calls for a change to the procedures for managing IPK.


Assuntos
Ceratose , Infecções por Papillomavirus , Verrugas , Humanos , Infecções por Papillomavirus/complicações , Infecções por Papillomavirus/epidemiologia , Papillomavirus Humano , Estudos Prospectivos , Verrugas/epidemiologia , Papillomaviridae/genética , DNA Viral/genética , DNA Viral/análise
2.
J Appl Clin Med Phys ; 24(9): e14053, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37247259

RESUMO

PURPOSE: The CyberKnife quality assurance (QA) program relies mainly on the use of radiochromic film (RCF). We aimed at evaluating high-resolution arrays of detectors as an alternative to films for CyberKnife machine QA. METHODS: This study will test the SRS Mapcheck (Sun Nuclear, Melbourne, Florida, USA) diode array and its own software, which allows three tests of the CyberKnife QA program to be performed. The first one is a geometrical accuracy test based on the delivery of two orthogonal beams (Automated Quality Assurance, AQA). Besides comparing the constancy and repeatability of both methods, known errors will be introduced to check their sensitivity. The second checks the constancy of the iris collimator field sizes (Iris QA). Changes in the field sizes will be introduced to study the array sensitivity. The last test checks the correct positioning of the multileaf collimator (MLC). It will be tested introducing known systematic displacements to whole banks and to single leaves. RESULTS: The results of the RCF and diode array were equivalent (maximum differences of 0.18 ± 0.14 mm) for the AQA test, showing the array a higher reproducibility. When known errors were introduced, both methods behaved linearly with similar slopes. Regarding Iris QA, the array measurements are highly linear when changes in the field sizes are introduced. Linear regressions show slopes of 0.96-1.17 with r2 above 0.99 in all field sizes. Diode array seems to detect changes of 0.1 mm. In MLC QA, systematic errors of the whole bank of leaves were not detected by the array, while single leaf errors were detected. CONCLUSIONS: The diode array is sensitive and accurate in the AQA and Iris QA tests, which give us the possibility of substituting RCF with a diode array. QA would be performed faster than using the film procedure, obtaining reliable results. Regarding the MLC QA, the inability to detect systematic displacements make it difficult to confidently use the detector.


Assuntos
Radioterapia de Intensidade Modulada , Software , Humanos , Reprodutibilidade dos Testes , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica
3.
J Appl Clin Med Phys ; 24(8): e14006, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37097754

RESUMO

PURPOSE: To study and analyze the effect of the use of a thin guide-wire instead of a Foley catheter for urethral definition in prostate stereotactic body radiation therapy (SBRT) treatments and to compare treatment parameters in both situations. MATERIAL AND METHODS: Thirty-seven prostate SBRT patients were employed in this study. A Foley catheter was employed in nine of them, and a guide-wire was employed in the other 28 patients. For each of the 28 patients in which the guide-wire was employed, a comparison between urethral positions in both situations was performed, allowing for a margin definition of the urethra when a Foley catheter was employed. Displacements of the prostate during treatment were obtained, allowing for an analysis of prostate positions in both situations. Also, different treatment parameters such as the number of treatment interruptions, couch movements performed, and x-rays needed were gathered. RESULTS: Large differences between urethral positions can be found in the anterior-posterior (AP) directions compared to those in the lateral (LAT) direction. Differences are also larger in areas closer to the base of the prostate, where margins applied in the case of using a Foley catheter are 16 mm with a mean displacement of 6 mm in the posterior direction. No differences in the treatment parameters were found during treatment in both situations. The difference found in absolute prostate pitch rotations suggests that the Foley catheter provokes a shift of the prostate position, which does not occur when employing the guide-wire. CONCLUSIONS: Foley catheters shift the urethral position, making them a wrong surrogate of the urethra when no catheters are present. The margins needed to assess uncertainties introduced by the use of a Foley catheter are larger than those usually applied. The use of a Foley catheter did not present any additional difficulty during treatment delivery in terms of images employed or interruptions produced.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Uretra , Próstata , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Cateterismo Urinário
4.
Int Wound J ; 19(2): 362-369, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34114747

RESUMO

The benefit of autologous platelet-rich plasma (PRP) treatment is still under discussion. Variations in PRP products, consequence of the lack of a standardised protocol for the multitude of commercially available blood separation systems and the lack of knowledge of the optimal composition of PRP or its suitability for the proposed indication are some of the reasons behind clinical inconsistencies. The impact of inter-subject variability in PRP has received less attention in comparison. The purpose of this study was to determine the inter-subject variability, based on age, in the concentrates prepared by a new blood concentration system. Twenty-six healthy volunteers of both genders (29-93 years) were enrolled. Whole blood (WB) was collected from each participant to prepare PRP using the Easy PRP kit. Platelets and white blood cells (WBC) from WB and PRP were analysed after split population by age; patients younger than 65 years (n = 13) and patients ≥65 years old (n = 13). Among the demographic characteristics tested, only age was significantly different between the groups. Cell capture efficiency of the system was specific for each type of blood cell and identical for both age groups. Platelets and WBC in PRP were higher than in WB (P < .001). In WB, platelets and WBC concentrations were significantly lower in older group (P ≤ .035). These differences persisted in the prepared PRP (P ≤ .004). The ageing of population has a strong influence on the haematocrit and therefore on the composition of PRP. Because the efficiency of blood separator system seems to be constant across individuals, the inter-subject haematocrit variability based on age could be used as a predictor of resulting PRP. The clinical application of PRP should be restricted to the specific cell capture capacity of the different commercial devices.


Assuntos
Plaquetas , Plasma Rico em Plaquetas , Idoso , Feminino , Voluntários Saudáveis , Humanos , Contagem de Leucócitos , Leucócitos , Masculino
5.
Plant Physiol ; 179(3): 969-985, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30397021

RESUMO

Edible berries are considered to be among nature's treasure chests as they contain a large number of (poly)phenols with potentially health-promoting properties. However, as berries contain complex (poly)phenol mixtures, it is challenging to associate any interesting pharmacological activity with a single compound. Thus, identification of pharmacologically interesting phenols requires systematic analyses of berry extracts. Here, raspberry (Rubus idaeus, var Prestige) extracts were systematically analyzed to identify bioactive compounds against pathological processes of neurodegenerative diseases. Berry extracts were tested on different Saccharomyces cerevisiae strains expressing disease proteins associated with Alzheimer's, Parkinson's, or Huntington's disease, or amyotrophic lateral sclerosis. After identifying bioactivity against Huntington's disease, the extract was fractionated and the obtained fractions were tested in the yeast model, which revealed that salidroside, a glycosylated phenol, displayed significant bioactivity. Subsequently, a metabolic route to salidroside was reconstructed in S cerevisiae and Corynebacterium glutamicum The best-performing S cerevisiae strain was capable of producing 2.1 mm (640 mg L-1) salidroside from Glc in shake flasks, whereas an engineered C glutamicum strain could efficiently convert the precursor tyrosol to salidroside, accumulating up to 32 mm (9,700 mg L-1) salidroside in bioreactor cultivations (yield: 0.81 mol mol-1). Targeted yeast assays verified that salidroside produced by both organisms has the same positive effects as salidroside of natural origin.


Assuntos
Glucosídeos/biossíntese , Proteína Huntingtina/química , Doença de Huntington/metabolismo , Extratos Vegetais/química , Rubus/química , Vias Biossintéticas , Fracionamento Químico , Glucosídeos/química , Glucosídeos/metabolismo , Modelos Biológicos , Fenóis/química , Fenóis/metabolismo , Extratos Vegetais/isolamento & purificação , Saccharomyces cerevisiae/efeitos dos fármacos , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo
6.
J Appl Clin Med Phys ; 21(8): 56-64, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32472618

RESUMO

PURPOSE: To compare tumor motion amplitudes measured with 2D fluoroscopic images (FI) and with an inhale/exhale CT (IECT) technique MATERIALS AND METHODS: Tumor motion of 52 patients (39 lung patients and 13 liver patients) was obtained with both FI and IECT. For FI, tumor detection and tracking was performed by means of a software developed by the authors. Motion amplitude and, thus, internal target volume (ITV), were defined to cover the positions where the tumor spends 95% of the time. The algorithm was validated against two different respiratory motion phantoms. Motion amplitude in IECT was defined as the difference in the position of the centroid of the gross tumor volume in the image sets of both treatments. RESULTS: Important differences exist when defining ITVs with FI and IECT. Overall, differences larger than 5 mm were obtained for 49%, 31%, and 9.6% of the patients in Superior-Inferior (SI), Anterior-Posterior (AP), and Lateral (LAT) directions, respectively. For tumor location, larger differences were found for tumors in the liver (73.6% SI, 27.3% AP, and 6.7% in LAT had differences larger than 5 mm), while tumors in the upper lobe benefitted less using FI (differences larger than 5 mm were only present in 27.6% (SI), 36.7% (AP), and 0% (LAT) of the patients). CONCLUSIONS: Use of FI with the linac built-in CBCT system is feasible for ITV definition. Large differences between motion amplitudes detected with FI and IECT methods were found. The method presented in this work based on FI could represent an improvement in ITV definition compared to the method based on IECT due to FI permits tumor motion acquisition in a more realistic situation than IECT.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Tomografia Computadorizada Quadridimensional , Humanos , Fígado/diagnóstico por imagem , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Planejamento da Radioterapia Assistida por Computador , Respiração , Tomografia Computadorizada por Raios X , Raios X
7.
J Antimicrob Chemother ; 69(6): 1624-32, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24505092

RESUMO

OBJECTIVES: To explore the pharmacokinetics (PK) and pharmacodynamics (PD) of micafungin in patients undergoing continuous venovenous haemofiltration (CVVH). PATIENTS AND METHODS: Ten patients receiving CVVH treated with 100 mg/day micafungin were included (April-December 2012). CVVH was performed using polyethersulphone or polysulphone haemofilters. Dialysis membranes were not changed on sampling days. On Days 1 and 2, blood samples from arterial pre-filter and venous post-filter ports and ultrafiltrate samples were collected at the start and end of the infusion and at 3, 5, 8, 18 and 24 h. Concentrations were determined using HPLC. Values for the area under the concentration-time curve (AUC0-24) were calculated. Monte Carlo simulations were performed using pre-filter and post-filter AUC0-24/MIC ratios on Days 1 and 2. The probability of target attainment (PTA) was calculated using AUC0-24/MIC cut-offs: 285 (C. parapsilosis), 3000 (all Candida spp.) and 5000 (non-parapsilosis Candida spp.). Cumulative fraction responses (CFRs) were calculated using EUCAST MIC distributions. RESULTS: Mean post-filter AUC0-24 (mg·h/L) values were higher than pre-filter values on Day 1 (83.31 ±â€Š15.87 versus 71.31 ±â€Š14.24; P = 0.008) and Day 2 (119.01 ±â€Š27.20 versus 104.54 ±â€Š21.23; P = 0.005). PTAs were ≥90% for MICs of 0.125 mg/L (cut-off = 285), 0.016 mg/L (cut-off = 3000) and 0.008 mg/L (cut-off = 5000) on Day 1, and for MICs of 0.25 mg/L (cut-off = 285) and 0.016 mg/L (cut-off = 3000 and 5000) on Day 2, without differences between pre- and post-filter values. On Day 2, CFRs >90% were obtained for C. albicans (cut-off = 3000 and 5000) and C. glabrata (cut-off = 3000), but not for C. parapsilosis. CONCLUSIONS: There was no removal of micafungin by CVVH or need for dose adjustment, and there was optimal PK/PD coverage for non-parapsilosis Candida and equivalence of pre- and post-filter PD.


Assuntos
Antifúngicos/farmacocinética , Candida/efeitos dos fármacos , Candidíase Invasiva/tratamento farmacológico , Estado Terminal/terapia , Equinocandinas/farmacocinética , Hemofiltração , Lipopeptídeos/farmacocinética , Idoso , Idoso de 80 Anos ou mais , Antifúngicos/uso terapêutico , Candidíase Invasiva/diagnóstico , Candidíase Invasiva/microbiologia , Equinocandinas/uso terapêutico , Feminino , Hemofiltração/efeitos adversos , Humanos , Unidades de Terapia Intensiva , Lipopeptídeos/uso terapêutico , Masculino , Micafungina , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Método de Monte Carlo
8.
Antibiotics (Basel) ; 13(5)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38786198

RESUMO

Despite the advantages of surgical handrub in terms of the ease of application and effectiveness, chlorhexidine (CHG)-based hand scrubbing remains the preferred method for surgical hand preparation. However, it does not systematically meet the non-inferiority requirement of the European norm (EN) 12791 with respect to n-propanol (the reference product) and does not provide the sustained efficacy expected for these long-lasting agents. Commercially available alcohol-based products have also failed to demonstrate sustained efficacy according to EN 12791. Multi-step protocols enhance the efficacy of hand scrubbing, yet their extended disinfection duration might diminish their allure for healthcare professionals. In this study, we show that hand scrubbing with CHG 4% followed by a 1 min rubbing with the novel formulation of ethanol (Et) 70%/CHG 3% plus 0.3% potassium sorbate food additive (PS) meets the non-inferiority requirement and demonstrates sustained efficacy when tested according to EN 12791. The immediate and 3 h effect of this protocol was significantly higher than that of n-propanol and the homologous disinfection protocol without PS (CHG 4% hand scrub plus Et 70%/CHG 3% rub), demonstrating that the inclusion of PS confers a notable residual effect. We speculate that this non-volatile ingredient acts synergistically with CHG. This promising combination represents an alternative method for the development of new disinfection strategies.

9.
Antibiotics (Basel) ; 13(2)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38391561

RESUMO

The surface adhesion of bacterial cells and the in vivo biocompatibility of a new ceramic-metal composite made of zirconium dioxide and tantalum were evaluated. Within the framework of an in vitro study using the crystal violet staining and colony counting methods, a relatively similar adhesion of Streptococcus oralis to the 3Y-TZP/Ta biocermet (roughness Ra = 0.12 ± 0.04 µm) and Ti-Al6-V4 titanium alloy (Ra = 0.04 ± 0.01 µm) was found. In addition, in an in vivo preliminary study focused on the histological analysis of a series of rods implanted in the jaws of beagle dogs for a six-month period, the absence of any fibrous tissue or inflammatory reaction at the interface between the implanted 3Y-TZP/Ta biocermets and the new bone was found. Thus, it can be concluded that the developed ceramic-metal biocomposite may be a promising new material for use in dentistry.

10.
J Antimicrob Chemother ; 68(10): 2291-5, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23674766

RESUMO

OBJECTIVES: To explore serum and tissue pharmacodynamics of linezolid versus vancomycin against methicillin-resistant Staphylococcus aureus (MRSA) clinical isolates with different MBC/MIC ratios. METHODS: Five strains (vancomycin MIC/MBCs, mg/L) were used: TOL-1 (2/≥64), TOL-2 (1/16), LT-1 and LT-2 (1/8) and NT (1/2). The linezolid MIC/MBC for all strains was 2/≥64 mg/L. A two-compartment dynamic computerized device was used (inocula 10(7) cfu/mL). Free concentrations obtained in serum and interstitial fluid with twice-daily regimens of 1 g of vancomycin or 600 mg of linezolid were simulated over 48 h. ABBCs (differences between control growth curves and killing curves of bacteria exposed to antibiotics; log10 cfu × h/mL) and log10 reductions in initial inocula were calculated. RESULTS: In serum simulations, vancomycin (AUC0-24/MIC = 251.8 for TOL-1 and 503.6 for the remaining strains) was bacteriostatic against strains with MBC/MIC ≥8, but bactericidal against NT. In interstitial fluid simulations (AUC0-24/MIC = 54.6 for TOL-1 and 109.2 for the remaining strains), initial inocula grew in all cases. Linezolid, both in serum (AUC0-24/MIC = 87.0) and in interstitial fluid (AUC0-24/MIC = 130.6) simulations, reduced initial inocula ≥2.2 log10 for all strains (apart from LT-1 in serum simulations that showed a bacteriostatic profile). ABBCs were similar in serum and interstitial fluid with linezolid, but significantly lower in interstitial fluid simulations with vancomycin. CONCLUSIONS: From the pharmacodynamic perspective (serum concentrations), vancomycin tolerance should include MBC/MIC ≥8 since strains exhibiting this ratio showed bacteriostatic profiles similar to those obtained with isolates with MBC/MIC ratios of 16 or 32. Insufficient concentrations of vancomycin at the simulated infected site were linked to bacteriological failure. Free concentrations of linezolid at the infection site pharmacodynamically covered MRSA.


Assuntos
Acetamidas/farmacologia , Antibacterianos/farmacologia , Líquido Extracelular/química , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Oxazolidinonas/farmacologia , Soro/química , Vancomicina/farmacologia , Acetamidas/farmacocinética , Antibacterianos/farmacocinética , Diabetes Mellitus , Humanos , Linezolida , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Testes de Sensibilidade Microbiana , Viabilidade Microbiana/efeitos dos fármacos , Modelos Teóricos , Oxazolidinonas/farmacocinética , Vancomicina/farmacocinética
11.
Infect Control Hosp Epidemiol ; 44(3): 517-519, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34933701

RESUMO

Triclosan 0.5% by scrubbing does not meet the UNE-EN12791 criteria to be used in the surgical hand preparation (SHP). Triclosan 0.5% by scrubbing followed by ethanol 70% hand rubbing is suitable without the additional characteristic of sustained effect. This limited effectiveness implies that triclosan should be avoided in SHP given the restrictions on its use in consumer antiseptic products. The trial was registered at ClinicalTrials.gov (ID: NCT04538365).


Assuntos
Anti-Infecciosos Locais , Triclosan , Humanos , Triclosan/farmacologia , Carga Bacteriana , Desinfecção das Mãos , Anti-Infecciosos Locais/farmacologia , Antissepsia
12.
Cancer Diagn Progn ; 3(4): 433-438, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37405211

RESUMO

BACKGROUND/AIM: The optimal imaging test for delineation of the gross tumor volume (GTV) in hepatocellular carcinoma has not been defined. The hypothesis is that magnetic resonance imaging (MRI) allows for better visualization of the extent of tumor and will optimize the accuracy of tumor delineation for liver stereotactic radiotherapy compared with computed tomography (CT) only. We evaluated the interobserver agreement in GTV of hepatocellular carcinoma in a multicenter panel and compared MRI and CT in GTV delineation. MATERIALS AND METHODS: After the institutional review boards approved the study, we analyzed anonymous CT and MRI obtained from five patients with hepatocellular carcinoma. Eight radiation oncologists at our center used CT and MRI to delineate five GTVs of liver tumors. In both CT and MRI, the GTV volumes were compared. RESULTS: The median GTV volume on MRI was 2.4 cm3 (range=0.59-15.6 cm3) compared to 3.5 cm3 (range=0.52-24.9 cm3) on CT (p=0.36). The GTV volume as defined on MRI was larger or at least as large as the GTV volume on CT in two cases. Variance and standard deviation between observers in CT and MRI were minor (6 vs. 7.87 cm3, and 2.5 vs. 2.8 cm3 respectively). CONCLUSION: In cases with well-defined tumors, CT is easier and reproducible. In cases with no defined tumor in CT, other tools are needed and MRI can be complementary. The interobserver variability in target delineation of hepatocellular carcinoma in this study is noteworthy.

13.
Nat Commun ; 14(1): 1918, 2023 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-37024503

RESUMO

Parkinson's Disease (PD) is a common neurodegenerative disorder affecting millions of people worldwide for which there are only symptomatic therapies. Small molecules able to target key pathological processes in PD have emerged as interesting options for modifying disease progression. We have previously shown that a (poly)phenol-enriched fraction (PEF) of Corema album L. leaf extract modulates central events in PD pathogenesis, namely α-synuclein (αSyn) toxicity, aggregation and clearance. PEF was now subjected to a bio-guided fractionation with the aim of identifying the critical bioactive compound. We identified genipin, an iridoid, which relieves αSyn toxicity and aggregation. Furthermore, genipin promotes metabolic alterations and modulates lipid storage and endocytosis. Importantly, genipin was able to prevent the motor deficits caused by the overexpression of αSyn in a Drosophila melanogaster model of PD. These findings widens the possibility for the exploitation of genipin for PD therapeutics.


Assuntos
Doença de Parkinson , alfa-Sinucleína , Animais , alfa-Sinucleína/metabolismo , Drosophila melanogaster/metabolismo , Doença de Parkinson/metabolismo , Iridoides/farmacologia , Fenóis , Lipídeos
14.
Med Phys ; 39(11): 6972-80, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23127091

RESUMO

PURPOSE: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. METHODS: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. RESULTS: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments showed that, while treatments affected by latency effects were improved, those affected by individual leaf errors were not. CONCLUSIONS: Measurement of MLC performance in real treatments provides the authors with a valuable tool for ensuring the quality of HT delivery. The LOTs of MLC are very accurate in most cases. Sources of error were found and correction methods proposed and applied. The corrections decreased the amount of LOT errors. The dosimetric impact of these corrections should be evaluated more thoroughly using 3D dose distribution analysis.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Imagens de Fantasmas , Erros de Configuração em Radioterapia , Fatores de Tempo
15.
J Water Health ; 10(3): 400-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22960484

RESUMO

The aim of this study was to determine the survival of human pathogens (Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa) in five natural mineral waters (NMWs) with different properties and mineralization levels. Five NMWs from four Spanish spas with different dry residue at 110 °C were used: A = 76,935 mg/L; B = 1,827 mg/L; C = 808.4 mg/L; D = 283.8 mg/L; and E = 170.4 mg/L. An initial inoculum of 1 × 10(6) colony forming units (cfu)/mL was used for survival studies. Distilled water, chlorinated tap water and Mueller-Hinton broth were used as controls. Colony counts in all different waters were lower than those achieved with Mueller-Hinton broth over all incubation periods. A direct effect between the bacterial survival and the level of mineralization water was observed. The NMW E with low mineralization level along with the radioactive properties showed the highest antibacterial activity among all NMWs.


Assuntos
Águas Minerais/microbiologia , Bactérias , Balneologia , Humanos , Espanha , Fatores de Tempo
16.
J Clin Med ; 11(6)2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35330008

RESUMO

Few studies have checked the impact of the hormonal/immunological dimorphism of patients on the cellular composition of platelet-rich plasma products (PRP). Whole blood (WB) from 26 volunteers was concentrated using a device previously characterized. Platelet and white blood cell (WBC) counts in WB and PRP were compared between genders, and after the population was split into pre (≤50 years)- and post (>50 years)-menopausal ages. In WB, platelet−total WBC densities were comparable in men and women. The phagocytic cell composition differed (p ≤ 0.04). After dividing by ages, phagocytic cell discrepancies were linked to women > 50 years (p ≤ 0.05), and differences emerged in lymphocyte counts (lower in >50 years groups, within and between genders, p ≤ 0.05). In PRP, densities were significantly higher, but the PRP/WB ratios varied according to blood cell (lower for phagocytic cells) and between subjects (more favorable at a lower density of a particular blood cell in WB). This "system compensatory efficiency" reduced/reverted PRP differences in the leukocyte composition between genders/age−sex groups in WB. In PRP, neutrophils were higher in younger men than older women (p < 0.05). WB lymphocyte differences between age−sex groups persisted. Age is a more determining factor than sex in the preparation of PRP. Post-menopause, sexual dimorphism strongly influences the composition of leukocytes, also conditioned by the capture efficiency of the system.

17.
J Clin Med ; 11(5)2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35268430

RESUMO

Background: Over-supination processes of the foot and ankle involving peroneus longus (PL) damage during running sports have been treated conservatively with passive control tools, such as tapes, braces, or external ankle supports, but the effect of orthoses with typical lateral wedging orthoses (TLWO) on the muscular activity of PL during running remains unclear. Here we investigate the effects of innovative medial cushioning orthoses (IMCO) on PL activity during the full running gait cycle. In addition, we wished to ascertain the effects of innovative medial cushioning orthoses (IMCO) on PL activity during running. Methods: Thirty-one healthy recreational runners (mean age 34.5 ± 3.33) with neutral foot posture index scores, were selected to participate in the present study. They ran on a treadmill at 9 km/h wearing seven different orthoses (NRS, IMCO 3 mm, IMCO 6 mm, IMCO 9 mm, TLWO 3 mm, TLWO 6 mm and TLWO 9 mm), randomly performed on the same day while electromyographic activity of the PL muscle was recorded. Statistical intraclass correlation coefficient (ICC) to test reliability was carried out and the Wilcoxon test with Bonferroni's correction was developed to analyze the differences between the conditions. Results: the reliability of all assessments showed data higher than 0.81, that is, "almost perfect reliability"; all EMG PL values wearing either TLWO or IMCO showed a statistically significant reduction versus NRS during the fully analyzed running gait cycle; the highest difference was set on NRS 23.08 ± 6.67 to TLWO 9 mm 17.77 ± 4.794 (p < 0.001). Conclusions: Muscular EMG activity of the PL during the full running gait cycle decreases when wearing either TLWO or IMCO relative to NRS; therefore, these orthoses could be prescribed to treat the strain and overload pathologies of PL. In addition, IMCO­as it less thick, compared with TLWO­can be used when aiming to achieve better running economy.

18.
Antimicrob Agents Chemother ; 55(6): 2788-94, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21464255

RESUMO

This study explores the effects of cefditoren (CDN) versus amoxicillin-clavulanic acid (AMC) on the evolution (within a single strain) of total and recombined populations derived from intrastrain ftsI gene diffusion in ß-lactamase-positive (BL⁺) and ß-lactamase-negative (BL⁻) Haemophilus influenzae. DNA from ß-lactamase-negative, ampicillin-resistant (BLNAR) isolates (DNA(BLNAR)) and from ß-lactamase-positive, amoxicillin-clavulanate-resistant (BLPACR) (DNA(BLPACR)) isolates was extracted and added to a 107-CFU/ml suspension of one BL⁺ strain (CDN MIC, 0.007 µg/ml; AMC MIC, 1 µg/ml) or one BL⁻ strain (CDN MIC, 0.015 µg/ml; AMC MIC, 0.5 µg/ml) in Haemophilus Test Medium (HTM). The mixture was incubated for 3 h and was then inoculated into a two-compartment computerized device simulating free concentrations of CDN (400 mg twice a day [b.i.d.]) or AMC (875 and 125 mg three times a day [t.i.d.]) in serum over 24 h. Controls were antibiotic-free simulations. Colony counts were performed; the total population and the recombined population were differentiated; and postsimulation MICs were determined. At time zero, the recombined population was 0.00095% of the total population. In controls, the BL⁻ and BL⁺ total populations and the BL⁻ recombined population increased (from ≈3 log10 to 4.5 to 5 log10), while the BL⁺ recombined population was maintained in simulations with DNA(BLPACR) and was decreased by ≈2 log10 with DNA(BLNAR). CDN was bactericidal (percentage of the dosing interval for which experimental antibiotic concentrations exceeded the MIC [ft>MIC], >88%), and no recombined populations were detected from 4 h on. AMC was bactericidal against BL⁻ strains (ft>MIC, 74.0%) in DNA(BLNAR) and DNA(BLPACR) simulations, with a small final recombined population (MIC, 4 µg/ml; ft>MIC, 30.7%) in DNA(BLPACR) simulations. When AMC was used against the BL⁺ strain (in DNA(BLNAR) or DNA(BLPACR) simulations), the bacterial load was reduced ≈2 log10 (ft>MIC, 44.3%), but 6.3% and 32% of the total population corresponded to a recombined population (MIC, 16 µg/ml; ft>MIC, 0%) in DNA(BLNAR) and DNA(BLPACR) simulations, respectively. AMC, but not CDN, unmasked BL⁺ recombined populations obtained by transformation. ft>MIC values higher than those classically considered for bacteriological response are needed to counter intrastrain ftsI gene diffusion by covering recombined populations.


Assuntos
Combinação Amoxicilina e Clavulanato de Potássio/farmacologia , Antibacterianos/farmacologia , Cefalosporinas/farmacologia , Genes Bacterianos , Haemophilus influenzae/efeitos dos fármacos , Combinação Amoxicilina e Clavulanato de Potássio/farmacocinética , Cefalosporinas/farmacocinética , Difusão , Farmacorresistência Bacteriana , Haemophilus influenzae/genética , Humanos , Testes de Sensibilidade Microbiana , beta-Lactamases/análise
19.
Infect Control Hosp Epidemiol ; 42(11): 1382-1384, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33478620

RESUMO

A crossover trial was conducted to compare hand rub and hand scrub-brush methods for reducing bacterial loads when using propan-1-ol-60% according to European regulations. Both methods significantly reduced the bacterial load immediately after antisepsis, but only the hand rub method achieved significant bacterial load reduction 3 hours after the procedure.


Assuntos
Anti-Infecciosos Locais , Antissepsia , Carga Bacteriana , Estudos Cross-Over , Mãos , Desinfecção das Mãos , Humanos
20.
Antibiotics (Basel) ; 10(5)2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-34068007

RESUMO

Antibiotic resistance in Streptococcus pneumoniae has increased worldwide, making fluoroquinolones an alternative therapeutic option. Fluoroquinolones inhibit the type II DNA topoisomerases (topoisomerase IV and gyrase). In this study we have evaluated the in vivo activity of seconeolitsine, an inhibitor of topoisomerase I. Levofloxacin (12.5 to 50 mg/kg) or seconeolitsine (5 to 40 mg/kg) were administered every 12 h during two days in mice infected with a serotype 8-resistant strain. At 48 h, a 70% protection was obtained with seconeolitsine (40 mg/kg; p < 0.001). However, survival with levofloxacin was 20%, regardless of the dose. In addition, seconeolitsine decreased bacteremia efficiently. Levofloxacin had higher levels in serum than seconeolitsine (Cmax of 14.7 vs. 1.6; p < 0.01) and higher values of area under the serum concentration-time curve (AUC0-12h of 17.3 vs. 5; p < 0.01). However, seconeolitsine showed higher levels of time to peak concentration and elimination half-life. This is consistent with the higher binding of seconeolitsine to plasma proteins (40% and 80% when used at 1 µg/mL and 50 µg/mL, respectively) in comparison to levofloxacin (12% at 5 µg/mL and 33% at 50 µg/mL). Our results suggest that seconeolitsine would be a promising therapeutic alternative against pneumococcal isolates with high fluoroquinolone resistance levels.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA