Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Ultrasound Med ; 41(12): 3125-3135, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35866181

RESUMO

This study assessed the feasibility of dynamic transperineal ultrasound (TPUS) pre/post-radical prostatectomy (RP). Ninety-eight patients were scanned pre-operatively and at four time-points post-operatively. TPUS was performed in 98 patients using an abdominal transducer at rest, during pelvic floor contraction (PFC) and Valsalva (VS) maneuver in supine and standing positions. Urodynamic evaluations included bladder neck angle at rest/PFC/VS, and degree of bladder neck movement. Pre-operative and post-operative measurements were technically feasible in >85% (supine) and >90% (standing) of patients. TPUS offers a reliable non-invasive dynamic assessment of the pelvic floor post-prostatectomy and may prove a useful adjunct for guiding exercises to preserve continence.


Assuntos
Diafragma da Pelve , Prostatectomia , Masculino , Humanos , Diafragma da Pelve/diagnóstico por imagem , Ultrassonografia , Bexiga Urinária/diagnóstico por imagem , Urodinâmica
2.
Magn Reson Med ; 86(1): 320-334, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33645815

RESUMO

PURPOSE: To develop an improved reconstruction method, k-space subtraction with phase and intensity correction (KSPIC), for highly accelerated, subtractive, non-contrast-enhanced MRA. METHODS: The KSPIC method is based on k-space subtraction of complex raw data. It applies a phase-correction procedure to restore the polarity of negative signals caused by subtraction and an intensity-correction procedure to improve background suppression and thereby sparsity. Ten retrospectively undersampled data sets and 10 groups of prospectively undersampled data sets were acquired in 12 healthy volunteers. The performance of KSPIC was compared with another improved reconstruction based on combined magnitude subtraction, as well as with conventional k-space subtraction reconstruction and magnitude subtraction reconstruction, both using quantitative metrics and using subjective quality scoring. RESULTS: In the quantitative evaluation, KSPIC had the best performance in terms of peak SNR, structural similarity index measure, contrast-to-noise ratio of artery-to-background and sharpness, especially at high acceleration factors. The KSPIC method also had the highest subjective scores for all acceleration factors in terms of vessel delineation, image noise and artifact, and background contamination. The acquisition can be accelerated by a factor of 20 without significant decreases of subjective scores. The optimal size of the phase-correction region was found to be 12-20 pixels in this study. CONCLUSION: Compared with combined magnitude subtraction and conventional reconstructions, KSPIC has the best performance in all of the quantitative and qualitative measurements, permitting good image quality to be maintained up to higher accelerations. The KSPIC method has the potential to further reduce the acquisition time of subtractive MRA for clinical examinations.


Assuntos
Angiografia por Ressonância Magnética , Técnica de Subtração , Artefatos , Artéria Femoral/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Estudos Retrospectivos
3.
Eur Radiol ; 31(5): 2696-2705, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33196886

RESUMO

OBJECTIVES: To assess the predictive value and correlation to pathological progression of the Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) scoring system in the follow-up of prostate cancer (PCa) patients on active surveillance (AS). METHODS: A total of 295 men enrolled on an AS programme between 2011 and 2018 were included. Baseline multiparametric magnetic resonance imaging (mpMRI) was performed at AS entry to guide biopsy. The follow-up mpMRI studies were prospectively reported by two sub-specialist uroradiologists with 10 years and 13 years of experience. PRECISE scores were dichotomized at the cut-off value of 4, and the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Diagnostic performance was further quantified by using area under the receiver operating curve (AUC) which was based on the results of targeted MRI-US fusion biopsy. Univariate analysis using Cox regression was performed to assess which baseline clinical and mpMRI parameters were related to disease progression on AS. RESULTS: Progression rate of the cohort was 13.9% (41/295) over a median follow-up of 52 months. With a cut-off value of category ≥ 4, the PRECISE scoring system showed sensitivity, specificity, PPV and NPV for predicting progression on AS of 0.76, 0.89, 0.52 and 0.96, respectively. The AUC was 0.82 (95% CI = 0.74-0.90). Prostate-specific antigen density (PSA-D), Likert lesion score and index lesion size were the only significant baseline predictors of progression (each p < 0.05). CONCLUSION: The PRECISE scoring system showed good overall performance, and the high NPV may help limit the number of follow-up biopsies required in patients on AS. KEY POINTS: • PRECISE scores 1-3 have high NPV which could reduce the need for re-biopsy during active surveillance. • PRECISE scores 4-5 have moderate PPV and should trigger either close monitoring or re-biopsy. • Three baseline predictors (PSA density, lesion size and Likert score) have a significant impact on the progression-free survival (PFS) time.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Conduta Expectante
4.
Eur Radiol ; 30(7): 4039-4049, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32166495

RESUMO

PURPOSE: To assess the added value of dynamic contrast-enhanced (DCE) in prostate MR in clinical practice. METHODS: Two hundred sixty-four patients underwent prostate MRI, with T2 and DWI sequences initially interpreted, prior to full multiparametric magnetic resonance imaging (mpMRI) interpretation using a Likert 1-5 scale. A prospective opinion was given on likely benefit of contrast prior to review of the DCE sequence, and retrospectively following full mpMRI review. The final histology result following targeted and/or systematic biopsy of the prostate was used for outcome purposes. RESULTS: Biparametric magnetic resonance imaging (bpMRI) and mpMRI were assigned the same score in 86% of cases; when dichotomising to a negative or positive MRI (Likert score ≥ 3), concordance increased to 92.8%. At Likert score ≥ 3 bpMRI detected 89.9% of all cancers and 93.5% clinically significant prostate cancers (csPCa) and mpMRI 90.7% and 94.6%, respectively. mpMRI had fewer false positives than bpMRI (11.4% vs 18.9%) and a lower Likert 3 rate (8.3% vs 17%), conferring higher specificity (74% vs 67%), but similar sensitivity (95% versus 94%) and ROC-AUC (90% vs 89%). At a positive MRI threshold of Likert ≥ 4, mpMRI had a higher sensitivity than bpMRI (89% versus 80%) and detected more csPCa (89.2% versus 79.6%). DCE was prospectively considered of potential benefit in 27.3%, but readers would only recall 11% of patients for DCE sequences, mainly to assess score 3 peripheral zone lesions. Following full mpMRI review, DCE was considered helpful in 28.4% of cases; in 23/75 (30.6%) of these cases this only became apparent after reviewing the sequence, reasons included increased confidence, presence of "safety-net" lesions or inflammatory lesions. CONCLUSION: BpMRI has equivalent cancer detection rates to mpMRI; however, mpMRI had fewer Likert 3 call rates and increased specificity and was subjectively considered of benefit by readers in 28.4% of cases. KEY POINTS: • bpMRI has similar cancer detection rates to the full mpMRI protocol at a positive MRI threshold of Likert 3. • mpMRI had fewer intermediate category 3 calls (8.3%) than bpMRI (17%) and fewer false positives than bpMRI (11.4% vs 18.9%), conferring higher specificity (74% vs 67%). • Readers considered DCE beneficial in 28.4% of cases, but in a relatively high number (30.6%) this only became apparent after reviewing the sequence.


Assuntos
Meios de Contraste/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Sensibilidade e Especificidade
5.
J Magn Reson Imaging ; 45(6): 1846-1853, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27902859

RESUMO

PURPOSE: To evaluate the diagnostic performance of velocity- and acceleration-sensitized noncontrast-enhanced magnetic resonance angiography (NCE-MRA) of the infrageniculate arteries using contrast-enhanced MRA (CE-MRA) as a reference standard. MATERIALS AND METHODS: Twenty-four patients with symptoms of peripheral arterial disease were recruited. Each patient's infrageniculate arterial tree was examined using a velocity-dependent flow-sensitized dephasing (VEL-FSD) technique, an acceleration-dependent (ACC-FSD) technique, and our conventional CE-MRA technique performed at 1.5T. The images were independently reviewed by two experienced vascular radiologists, who evaluated each vessel segment to assess visibility, diagnostic confidence, venous contamination, and detection of pathology. RESULTS: In all, 432 segments were evaluated by each of the three techniques by each reader in total. Overall diagnostic confidence was rated as moderate or high in 98.5% of segments with CE-MRA, 92.1% with VEL-FSD, and 79.9% with ACC-FSD. No venous contamination was seen in 96% of segments with CE-MRA, 72.2% with VEL-FSD, and 85.8% with ACC-FSD. Per-segment, per-limb, and per-patient sensitivities for detecting significant stenotic disease were 63.4%, 73%, and 92%, respectively, for ACC-FSD, and 65.3%, 87.2%, and 96% for VEL-FSD, and as such no significant statistical change was detected using McNemar's chi-squared test with P-values of 1.00, 0.13, and 0.77 obtained, respectively. CONCLUSION: Flow-dependent NCE-MRA techniques may have a role to play in evaluation of patients with peripheral vascular disease. Increased sensitivity of a velocity-based technique compared to an acceleration-based technique comes at the expense of greater venous contamination. LEVEL OF EVIDENCE: 2J. Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;45:1846-1853.


Assuntos
Aumento da Imagem/métodos , Perna (Membro)/irrigação sanguínea , Perna (Membro)/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Perna (Membro)/patologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
BJU Int ; 113(4): 610-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24053445

RESUMO

OBJECTIVES: To determine the optimal method for assessing stone volume, and thus stone burden, by comparing the accuracy of scalene, oblate, and prolate ellipsoid volume equations with three-dimensional (3D)-reconstructed stone volume. Kidney stone volume may be helpful in predicting treatment outcome for renal stones. While the precise measurement of stone volume by 3D reconstruction can be accomplished using modern computer tomography (CT) scanning software, this technique is not available in all hospitals or with routine acute colic scanning protocols. Therefore, maximum diameters as measured by either X-ray or CT are used in the calculation of stone volume based on a scalene ellipsoid formula, as recommended by the European Association of Urology. METHODS: In all, 100 stones with both X-ray and CT (1-2-mm slices) were reviewed. Complete and partial staghorn stones were excluded. Stone volume was calculated using software designed to measure tissue density of a certain range within a specified region of interest. Correlation coefficients among all measured outcomes were compared. Stone volumes were analysed to determine the average 'shape' of the stones. RESULTS: The maximum stone diameter on X-ray was 3-25 mm and on CT was 3-36 mm, with a reasonable correlation (r = 0.77). Smaller stones (<9 mm) trended towards prolate ellipsoids ('rugby-ball' shaped), stones of 9-15 mm towards oblate ellipsoids (disc shaped), and stones >15 mm towards scalene ellipsoids. There was no difference in stone shape by location within the kidney. CONCLUSIONS: As the average shape of renal stones changes with diameter, no single equation for estimating stone volume can be recommended. As the maximum diameter increases, calculated stone volume becomes less accurate, suggesting that larger stones have more asymmetric shapes. We recommend that research looking at stone clearance rates should use 3D-reconstructed stone volumes when available, followed by prolate, oblate, or scalene ellipsoid formulas depending on the maximum stone diameter.


Assuntos
Algoritmos , Cálculos Renais/patologia , Matemática , Software , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Cálculos Renais/diagnóstico por imagem , Radiografia
7.
Abdom Radiol (NY) ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38717615

RESUMO

PURPOSE: To evaluate the performance of MRI for detection of bladder cancer following transurethral resection of bladder tumour (TURBT). METHODS: This single-centre retrospective study included forty-one consecutive patients with bladder cancer who underwent bladder MRI after TURBT. Two uroradiologists retrospectively assessed the presence of tumour using bladder MRI with and without DWI (diffusion weighted imaging) using a five-point Likert scale. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated and inter-reader agreement was assessed. Histopathology was used as the reference standard. RESULTS: 24 out of 41 patients (58.5%) had no residual tumour or Tis (carcinoma in situ) after TURBT. Sensitivity, specificity, PPV and NPV for detection of tumour using T1WI (T1-weighted imaging) and T2WI (T2-weighted imaging) was 50.0%, 54.6%, 21.1%, and 81.8%, respectively and for T1WI, T2WI and DWI combined was 100%, 76.5%, 50.0% and 100%, respectively. Overestimation of tumour was more common than underestimation. MRI showed high accuracy for patients in whom there was no residual tumour (78.9%). Inter-reader agreement for tumour detection improved from fair (κ = 0.54) to moderate (κ = 0.70) when DWI was included. CONCLUSION: Non-contrast MRI with DWI showed high sensitivity and relatively high specificity for detection of residual tumour after TURBT. Inter-reader agreement improved from fair to moderate with the addition of DWI. MRI can be useful after TURBT in order to guide further management.

8.
J Endovasc Ther ; 20(4): 568-70, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23914869

RESUMO

PURPOSE: To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. CASE REPORT: A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. CONCLUSION: Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.


Assuntos
Aorta Abdominal/lesões , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Hemorragia/etiologia , Complicações Intraoperatórias/etiologia , Stents/efeitos adversos , Idoso , Humanos , Masculino , Espaço Retroperitoneal
9.
J Urol ; 185(4): 1513-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21334674

RESUMO

PURPOSE: We determined the role of factor inhibiting hypoxia-inducible factor-1 in prostate cancer specimens. MATERIALS AND METHODS: A tissue microarray of 152 prostate cancers was constructed and stained for factor inhibiting hypoxia-inducible factor-1, hypoxia-inducible factor-1α and 2α, and glucose transporter 1 as a prototypical downstream target of hypoxia-inducible factor-1α. Correlation analysis was done between these variables, and between factor inhibiting hypoxia-inducible factor-1, and clinical and pathological variables, including prostate specific antigen as a surrogate of recurrence. RESULTS: Factor inhibiting hypoxia-inducible factor-1 was expressed in the cytoplasm and/or the nucleus in 86.5% of tumors, including exclusive cytoplasmic expression in 51.3% and exclusive nuclear expression in 5.3%. Any nuclear and exclusive expression of factor inhibiting hypoxia-inducible factor was associated with poor prognosis on univariate analysis (p = 0.007 and 0.042, respectively). On multivariate analysis men with nuclear expression in tumors were twice as likely to experience recurrence (p = 0.034). CONCLUSIONS: Factor inhibiting hypoxia-inducible factor-1 is widely expressed in prostate tumors. Its differential subcellular expression suggests that regulation of its expression is an important factor in the activity of the hypoxia-inducible factor pathway. Its modulation may help treat hypoxia-inducible factor driven aggressive prostate cancer.


Assuntos
Núcleo Celular , Neoplasias da Próstata , Proteínas Repressoras/fisiologia , Núcleo Celular/química , Humanos , Masculino , Oxigenases de Função Mista , Prognóstico , Neoplasias da Próstata/mortalidade , Neoplasias da Próstata/patologia , Proteínas Repressoras/análise , Taxa de Sobrevida
10.
Br J Hosp Med (Lond) ; 82(2): 1-11, 2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33646031

RESUMO

Selective internal radiation therapy is a type of brachytherapy used to provide targeted radiotherapy, most commonly to treat primary or metastatic disease within the liver. This review outlines current clinical practice, dosimetric considerations, the pre-treatment workup and safety considerations before treatment. It also examines the clinical evidence for its use in patients with both primary and metastatic disease within the liver.


Assuntos
Braquiterapia , Carcinoma Hepatocelular , Neoplasias Hepáticas , Braquiterapia/efeitos adversos , Humanos , Neoplasias Hepáticas/radioterapia , Microesferas , Radioisótopos de Ítrio
11.
Br J Radiol ; 94(1122): 20201368, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33882250

RESUMO

OBJECTIVES: Obtaining informed consent is a mandatory part of modern clinical practice. The aim of this study was to identify how often complications relating to Interventional Radiology (IR) procedures were discussed with the patient prior to the procedure. METHODS: A retrospective analysis of 100 patients who experienced a complication related to an IR procedure was performed. The patient's procedure consent form was examined to identify whether the complication they experienced had been discussed as a possible risk. Other parts of the consent form relating to need for blood transfusion and the need for further procedures were also examined. RESULTS: 39% of patients who experienced a complication did not have the complication documented as a potential risk on the consent form. 14% of patients required a blood transfusion but were not consented for this. 42% of patients required a further procedure or operation but were not warned of this. CONCLUSION: The model of gaining informed consent on the day of procedure is no longer valid. Better education and the use of clinics, patient information sheets and other resources is essential. ADVANCES IN KNOWLEDGE: The paper highlights the inadequacies of the current model in gaining consent for IR procedures. A more comprehensive consent process making use of all available resources is essential.


Assuntos
Consentimento Livre e Esclarecido , Radiografia Intervencionista/efeitos adversos , Transfusão de Componentes Sanguíneos/estatística & dados numéricos , Feminino , Hospitais Universitários , Humanos , Masculino , Estudos Retrospectivos , Reino Unido
12.
J Surg Case Rep ; 2021(9): rjab410, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34531975

RESUMO

Percutaneous cholecystostomy is a treatment for acute calculous cholecystitis used in patients where surgery is high risk or challenging either to allow for surgical optimisation or as definitive treatment. In this case series we compare the outcomes of a transhepatic versus transperitoneal approach in patients undergoing percutaneous cholecystostomy for acute calculous cholecystitis. A retrospective review of patients from 2014 to 2019 was conducted and included demographics, percutaneous cholecystostomy route, complications and outcome. Fifty-one patients were included. Percutaneous cholecystostomy was placed transhepatically in 15 cases; transperitoneal in 30 cases; 6 cases had undetermined route. The transhepatic cohort had 43.5% fewer readmissions due to biliary sepsis, 32.5% fewer drain-related complications, and were less likely to require further treatment (32.5% reduction) compared to the transperitoneal cohort. In our experience, the transhepatic route is preferred due to fewer complications, fewer readmissions and a reduction in the need for further treatment.

13.
Cardiovasc Intervent Radiol ; 44(8): 1174-1183, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33973019

RESUMO

PURPOSE: To retrospectively analyse complications in endovascular aortic repair (EVAR) interventions and evaluate if the CIRSE (Cardiovascular and Interventional Radiological Society of Europe) complication classification system is appropriate as a standardized classification tool for EVAR patients. MATERIALS AND METHODS: Demographic, procedural and complication data in 719 consecutive patients undergoing EVAR at one institution from January 2014 to October 2019 were retrospectively reviewed. Data (imaging reports, procedural reports, nurse notes, discharge summary reports) were collected consulting the electronic patient record system (EPR) of the hospital and cleaned and stored in a Microsoft Excel database. All the procedures were analysed in consensus by two interventional radiology consultants and a resident radiologist and if an intra- , peri- or post-procedural complication occurred, a grade (1-6) was assigned using the CIRSE grading complication classification system. RESULTS: Twenty-five patients were excluded from the analysis because of invalid or incomplete data. The final population was made up of 694 patients (mean age 75,4 y.o., 616 male/78 female, min age 23 y.o., max age 97 y.o.). Complications emerged in 211 patients (30,4% of cases, 22 female/189 male). The number of patients with CIRSE grade I, II, III, IV, V and VI complications was 36 (17%), 17 (8%), 121 (57,3%), 15 (7,1%), 3 (1,4%), 19 (9%). Nineteen (2,6%) patients succumbed after EVAR. Thirty-four complications (16,1%) were related to vascular access. CONCLUSION: The CIRSE complication classification system represents a broadly applicable and feasible approach to evaluate the severity of complications in patients following EVAR. However, some deficit may be considered relevant and as starting standing-point for future improvements.


Assuntos
Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/classificação , Complicações Pós-Operatórias/etiologia , Radiologia Intervencionista , Adulto , Idoso , Idoso de 80 Anos ou mais , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Encaminhamento e Consulta , Estudos Retrospectivos , Índice de Gravidade de Doença , Sociedades Médicas , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Adulto Jovem
14.
Diagn Interv Radiol ; 26(2): 140-142, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32071021

RESUMO

A number of embolic agents are currently available each with their own properties. Precipitating hydrophobic injectable liquid (PHIL) is a new dimethyl sulfoxide (DMSO) compatible embolic agent with a number of specific properties which make it of interest to interventional radiologists. We review the use of PHIL in a non-neurointerventional setting, describing its use in a range of procedures such as trauma embolization, pseudoaneurysm embolization, and tumor embolization. PHIL's properties include a lack of skin discoloration, the possibility of rapid injection and a lack of glare artifact on follow-up computed tomography imaging. These properties make it an important new tool in the armamentarium of the body interventional radiologist.


Assuntos
Dimetil Sulfóxido/uso terapêutico , Embolização Terapêutica/métodos , Sequestradores de Radicais Livres/uso terapêutico , Radiologia Intervencionista/métodos , Dimetil Sulfóxido/administração & dosagem , Sequestradores de Radicais Livres/administração & dosagem , Humanos , Interações Hidrofóbicas e Hidrofílicas , Injeções
15.
Eur J Radiol ; 130: 109163, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32634757

RESUMO

PURPOSE: To evaluate the long-term clinical efficacy of the Tigris © stent (Gore ©) in femoropopliteal chronic total occlusions (CTOs). MATERIAL AND METHODS: This single centre retrospective study included 29 patients treated with 47 Tigris© stents for CTOs. Lesion location, type, length, revascularisation method, smoking status and diabetes were reviewed. Clinical follow-up was performed. Primary safety points were complications and adverse events. Secondary efficacy points were symptom deterioration, freedom from target lesion revascularization (TLR) and amputation rate. Freedom from TLR was evaluated with Kaplan-Meier analysis; Cox multivariable logistic regression analysis of the factors associated with stent re-occlusion was also performed. RESULTS: All procedures were technically successful without any peri- or post-procedural complications and adverse events. Median follow-up was 48 months (range: 7-70). Lesions were located in the superficial femoral (19), popliteal (3) and femoropopliteal (7) arteries with mean lesion length 13.9 ±â€¯7.6 cm. In 12 patients subintimal recanalization was performed. Freedom from TLR rates at 6, 12, 18, 24 and 36 months were 96.6 %, 85.7 %, 81.9 %, 78.2 % and 74.3 % respectively. No stent fracture was observed and no amputation was performed in any of the patients. Smoking status, the presence of diabetes, lesion localization and recanalization type were not associated with stent re-occlusion. CONCLUSION: This study demonstrated that use of a heparin coated vascular stent for femoropopliteal CTOs appears to offer satisfactory long-term results.


Assuntos
Anticoagulantes/uso terapêutico , Stents Farmacológicos , Artéria Femoral/cirurgia , Heparina/uso terapêutico , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Doença Crônica , Feminino , Artéria Femoral/fisiopatologia , Heparina/administração & dosagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
16.
Br J Radiol ; 93(1108): 20190929, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31971823

RESUMO

OBJECTIVE: To introduce capped biparametric (bp) MRI slots for follow-up imaging of prostate cancer patients enrolled in active surveillance (AS) and evaluate the effect on weekly variation in the number of AS cases and total MRI workload. METHODS: Three 20 min bpMRI AS slots on two separate days were introduced at Addenbrooke's Hospital, Cambridge. The weekly numbers of total prostate MRIs and AS cases recorded 15 months before and after the change (Groups 1 and 2, respectively). An intergroup variation in the weekly scan numbers was assessed using the coefficient of variance (CV) and mean absolute deviation; the Mann-Whitney U test was used for an intergroup comparison of the latter. RESULTS: In AS patients, a shift from considerable to moderate variation in weekly scan numbers was observed between the two groups (CV, 51.7 and 26.8%, respectively); mean absolute deviation of AS scans also demonstrated a significant decrease in Group 2 (1.28 vs 2.58 in Group 1; p < 0.001). No significant changes in the variation in total prostate MRIs were observed, despite a 10% increased workload in Group 2. CONCLUSION: A significant reduction in weekly variation of AS cases was demonstrated following the introduction of capped bpMRI slots, which can be used for more accurate long-term planning of MRI workload. ADVANCES IN KNOWLEDGE: The paper illustrates the potential of introducing capped AS MRI slots using a bp protocol to reduce weekly variation in demand and allow for optimising workflow, which will be increasingly important as the demands on radiology departments increase worldwide.


Assuntos
Imageamento por Ressonância Magnética/estatística & dados numéricos , Vigilância da População , Neoplasias da Próstata/diagnóstico por imagem , Carga de Trabalho/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Fatores de Tempo
17.
World J Clin Oncol ; 11(10): 761-808, 2020 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-33200074

RESUMO

The liver is the commonest site of metastatic disease for patients with colorectal cancer, with at least 25% developing colorectal liver metastases (CRLM) during the course of their illness. The management of CRLM has evolved into a complex field requiring input from experienced members of a multi-disciplinary team involving radiology (cross sectional, nuclear medicine and interventional), Oncology, Liver surgery, Colorectal surgery, and Histopathology. Patient management is based on assessment of sophisticated clinical, radiological and biomarker information. Despite incomplete evidence in this very heterogeneous patient group, maximising resection of CRLM using all available techniques remains a key objective and provides the best chance of long-term survival and cure. To this end, liver resection is maximised by the use of downsizing chemotherapy, optimisation of liver remnant by portal vein embolization, associating liver partition and portal vein ligation for staged hepatectomy, and combining resection with ablation, in the context of improvements in the functional assessment of the future remnant liver. Liver resection may safely be carried out laparoscopically or open, and synchronously with, or before, colorectal surgery in selected patients. For unresectable patients, treatment options including systemic chemotherapy, targeted biological agents, intra-arterial infusion or bead delivered chemotherapy, tumour ablation, stereotactic radiotherapy, and selective internal radiotherapy contribute to improve survival and may convert initially unresectable patients to operability. Currently evolving areas include biomarker characterisation of tumours, the development of novel systemic agents targeting specific oncogenic pathways, and the potential re-emergence of radical surgical options such as liver transplantation.

18.
Br J Radiol ; 93(1112): 20200298, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32479105

RESUMO

OBJECTIVE: To compare the performance of Likert and Prostate Imaging-Reporting and Data System (PI-RADS) multiparametric (mp) MRI scoring systems for detecting clinically significant prostate cancer (csPCa). METHODS: 199 biopsy-naïve males undergoing prostate mpMRI were prospectively scored with Likert and PI-RADS systems by four experienced radiologists. A binary cut-off (threshold score ≥3) was used to analyze histological results by three groups: negative, insignificant disease (Gleason 3 + 3; iPCa), and csPCa (Gleason ≥3 +4). Lesion-level results and prostate zonal location were also compared. RESULTS: 129/199 (64.8%) males underwent biopsy, 96 with Likert or PI-RADS score ≥3, and 21 with negative MRI. A further 12 patients were biopsied during follow-up (mean 507 days). Prostate cancer was diagnosed in 87/199 (43.7%) patients, 65 with (33.6%) csPCa. 30/92 (32.6%) patients with negative MRI were biopsied, with an NPV of 83.3% for cancer and 86.7% for csPCa. Likert and PI-RADS score differences were observed in 92 patients (46.2%), but only for 16 patients (8%) at threshold score ≥3. Likert scoring had higher specificity than PI-RADS (0.77 vs 0.66), higher area under the curve (0.92 vs 0.87, p = 0.002) and higher PPV (0.66 vs 0.58); NPV and sensitivity were the same. Likert had more five score results (58%) compared to PI-RADS (36%), but with similar csCPa detection (81.0 and 80.6% respectively). Likert demonstrated lower proportion of false positive in the predominately AFMS-involving lesions. CONCLUSION: Likert and PI-RADS systems both demonstrate high cancer detection rates. Likert scoring had a higher AUC with moderately higher specificity and lower positive call rate and could potentially help to reduce the number of unnecessary biopsies performed. ADVANCES IN KNOWLEDGE: This paper illustrates that the Likert scoring system has potential to help urologists reduce the number of prostate biopsies performed.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
ScientificWorldJournal ; 9: 343-8, 2009 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-19468655

RESUMO

Transrectal ultrasound (TRUS)-guided prostate biopsy is known to carry a significant false-negative rate, leading some patients to have multiple biopsies. We investigated cancer detection rates in patients with a PSA > 20 ng/ml and a negative initial biopsy. We reviewed our database of 2396 TRUS-guided biopsies done between 1997 and 2002 in order to give a follow-up of at least 6 years. PSA, PSA density (PSAD), PSA velocity (PSAV), prostate volume, and DRE findings were analysed in relation to cancer status. Of the patients, 388 (16%) had a PSA > 20 ng/ml, including 99 (26%) with benign biopsies. Of those, 67 were rebiopsied, including 19 (28%) with cancer on the first rebiopsy and four (6%) on further biopsies. PSAD, DRE, and volume significantly differed between rebiopsied patients with and without cancer (p < 0.05). Patients who present with a PSA > 20 ng/ml and have an initial negative biopsy have a high chance of malignancy being detected on a second biopsy. However, if a second biopsy is also negative, then the chances of subsequent biopsies showing signs of cancer are very low if the DRE is normal and particularly if the PSAD is >0.35 ng/ml/cm3.


Assuntos
Biópsia/métodos , Antígeno Prostático Específico/sangue , Próstata/patologia , Neoplasias da Próstata/patologia , Bases de Dados Factuais/estatística & dados numéricos , Diagnóstico Diferencial , Exame Retal Digital , Humanos , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/sangue , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA