Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 311(2): e231809, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38805729

RESUMO

HISTORY: A 45-year-old female patient who was previously healthy presented after several weeks of fullness in the right upper quadrant of the abdomen. The patient did not experience pain, nausea, vomiting, or jaundice, and had no contributory past medical or surgical history, including no history of malignancy. Upon examination, vital signs were within normal limits and the patient was appeared well with soft palpable fullness in the right upper quadrant. The abdomen was nontender and nondistended. Laboratory investigation revealed no abnormalities, with a normal complete blood cell count and normal serum tumor markers that included α-fetoprotein (<2.0 ng/mL; reference, <8.3 ng/mL), cancer antigen 19-9 (21.6 U/mL; reference, <35 U/mL), and carcinoembryonic antigen (1.3 ng/mL; reference, <5 ng/mL). CT of the abdomen and pelvis was performed with intravenous contrast material in the emergency department (Fig 1). Subsequently, combined MRI and MR cholangiopancreatography of the abdomen was performed with and without intravenous contrast material for further evaluation (Fig 2). CT of the chest performed during the same encounter was unremarkable.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Diagnóstico Diferencial , Tomografia Computadorizada por Raios X/métodos , Colangiopancreatografia por Ressonância Magnética/métodos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos
2.
J Reconstr Microsurg ; 40(3): 177-185, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37236242

RESUMO

BACKGROUND: This study assesses associations between bioimpedance spectroscopy (BIS) and magnetic resonance lymphangiography (MRL) in the staging and assessment of lymphedema. METHODS: Adults who received MRL and BIS between 2020 and 2022 were included. We collected fluid, fat, and lymphedema severity ratings, and measured fluid stripe thickness, subcutaneous fat width, and lymphatic diameter on MRL. BIS lymphedema index (L-Dex) scores were collected from patient charts. We assessed sensitivity and specificity of L-Dex scores to detect MRL-identified lymphedema, and examined associations between L-Dex scores and MRL imaging measures. RESULTS: Forty-eight limbs across 40 patients were included. L-Dex scores had 72.5% sensitivity and 87.5% specificity for detecting MRL-defined lymphedema, with a 96.7% estimated positive predictive value and 38.9% negative predictive value. L-Dex scores were associated with MRL fluid and fat content scores (p ≤ 0.05), and lymphedema severity (p = 0.01), with better discrimination between fluid than fat content levels on pairwise analysis, and poor discrimination between adjacent severity levels. L-Dex scores were correlated with distal and proximal limb fluid stripe thickness (distal: rho = 0.57, p < 0.01; proximal: rho = 0.58, p < 0.01), partially correlated with distal subcutaneous fat thickness when accounting for body mass index (rho = 0.34, p = 0.02), and were not correlated with lymphatic diameter (p = 0.25). CONCLUSION: L-Dex scores have high sensitivity, specificity, and positive predictive value for the identification of MRL-detected lymphedema. L-Dex has difficulty distinguishing between adjacent severity levels of lymphedema and a high false negative rate, explained in part by reduced discrimination between levels of fat accumulation.


Assuntos
Vasos Linfáticos , Linfedema , Adulto , Humanos , Linfografia/métodos , Linfedema/patologia , Imageamento por Ressonância Magnética/métodos , Vasos Linfáticos/patologia , Espectroscopia de Ressonância Magnética
3.
Dis Colon Rectum ; 66(7): 973-982, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36876988

RESUMO

BACKGROUND: Short-course radiation therapy and consolidation chemotherapy with nonoperative intent has emerged as a novel treatment paradigm for patients with rectal cancer, but there are no data on the predictors of clinical complete response. OBJECTIVE: Evaluate the predictors of clinical complete response and survival. DESIGN: Retrospective cohort. SETTINGS: National Cancer Institute-designated cancer center. PATIENTS: Patients with stage I to III rectal adenocarcinoma treated between January 2018 and May 2019 (n = 86). INTERVENTIONS: Short-course radiation therapy followed by consolidation chemotherapy. MAIN OUTCOME MEASURES: Logistic regression was performed to assess for predictors of clinical complete response. The end points included local regrowth-free survival, regional control, distant metastasis-free survival, and overall survival. RESULTS: A positive (+) circumferential resection margin by MRI at diagnosis was a significant predictor of nonclinical complete response (OR: 4.1, p = 0.009) when adjusting for CEA level and primary tumor size. Compared to patients with a negative (-) pathologic circumferential resection margin, patients with a positive (+) pathologic circumferential resection margin had inferior local regrowth-free survival (29% vs 87%, p < 0.001), regional control (57% vs 94%, p < 0.001), distant metastasis-free survival (43% vs 95%, p < 0.001), and overall survival (86% vs 95%, p < 0.001) at 2 years. However, the (+) and (-) circumferential resection margin by MRI subgroups in patients who had a clinical complete response both had similar regional control, distant metastasis-free survival, and overall survival of more than 90% at 2 years. LIMITATIONS: Retrospective design, modest sample size, short follow-up, and the heterogeneity of treatments. CONCLUSIONS: Circumferential resection margin involvement by MRI at diagnosis is a strong predictor of nonclinical complete response. However, patients who achieve a clinical complete response after short-course radiation therapy and consolidation chemotherapy with nonoperative intent have excellent clinical outcomes regardless of the initial circumferential resection margin status. See Video Abstract at http://links.lww.com/DCR/C190 . EL MARGEN DE RESECCIN CIRCUNFERENCIAL COMO PREDICTOR NO CLNICO DE RESPUESTA COMPLETA EN EL MANEJO CONSERVADOR DEL CNCER DE RECTO: ANTECEDENTES:La radioterapia de corta duración y la quimioterapia de consolidación en el manejo conservador, han surgido como un nuevo paradigma de tratamiento, para los pacientes con cáncer de recto, lastimosamente no hay datos definitivos sobre los predictores de una respuesta clínica completa.OBJETIVO:Evaluar los predictores de respuesta clínica completa y de la sobrevida.DISEÑO:Estudio retrospectivo de cohortes.AJUSTES:Centro oncológico designado por el NCI.PACIENTES:Adenocarcinomas de recto estadio I-III tratados entre 01/2018 y 05/2019 (n = 86).INTERVENCIONES:Radioterapia de corta duración seguida de quimioterapia de consolidación.PRINCIPALES MEDIDAS DE RESULTADO:Se realizó una regresión logística para evaluar los predictores de respuesta clínica completa. Los criterios de valoración incluyeron la sobrevida libre de recidiva local, el control regional, la sobrevida libre de metástasis a distancia y la sobrevida general.RESULTADOS:Un margen de resección circunferencial positivo (+) evaluado por imagenes de resonancia magnética nuclear en el momento del diagnóstico fue un predictor no clínico muy significativo de respuesta completa (razón de probabilidades/ OR: 4,1, p = 0,009) al ajustar el nivel de antígeno carcinoembrionario y el tamaño del tumor primario. Comparando con los pacientes que presetaban un margen de resección circunferencial patológico negativo (-), los pacientes con un margen de resección circunferencial patológico positivo (+) tuvieron una sobrevida libre de recidiva local (29% frente a 87%, p < 0,001), un control regional (57% frente a 94%, p < 0,001), una sobrevida libre de metástasis a distancia (43% frente a 95%, p < 0,001) y una sobrevida global (86% frente a 95%, p < 0,001) inferior en 2 años de seguimiento. Sin embargo, los subgrupos de margen de resección circunferencial (+) y (-) evaluados por imágenes de resonancia magnética nuclear en pacientes que tuvieron una respuesta clínica completa tuvieron un control regional similar, una sobrevida libre de metástasis a distancia y una sobrevida general >90% en 2 años de seguimiento.LIMITACIONES:Diseño retrospectivo, tamaño modesto de la muestra, seguimiento corto y heterogeneidad de tratamientos.CONCLUSIONES:La afectación del margen de resección circunferencial evaluado por resonancia magnética nuclear al momento del diagnóstico es un fuerte factor predictivo no clínico de respuesta completa. Sin embargo, los pacientes que logran una respuesta clínica completa después de un curso corto de radioterapia y quimioterapia de consolidación como manejo conservador tienen excelentes resultados clínicos independientemente del estado del margen de resección circunferencial inicial. Consulte Video Resumen en http://links.lww.com/DCR/C190 . (Traducción-Dr. Xavier Delgadillo ).


Assuntos
Margens de Excisão , Neoplasias Retais , Humanos , Estudos Retrospectivos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/cirurgia , Reto/patologia , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Resultado do Tratamento
4.
Radiographics ; 43(12): e230073, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37917537

RESUMO

Advances in MRI technology have led to the development of low-field-strength (hereafter, "low-field") (0.55 T) MRI systems with lower weight, fewer shielding requirements, and lower cost than those of traditional (1.5-3 T) systems. The trade-offs of lower signal-to-noise ratio (SNR) at 0.55 T are partially offset by patient safety and potential comfort advantages (eg, lower specific absorption rate and a more cost-effective larger bore diameter) and physical advantages (eg, decreased T2* decay, shorter T1 relaxation times). Image reconstruction advances leveraging developing technologies (such as deep learning-based denoising) can be paired with traditional techniques (such as increasing the number of signal averages) to improve SNR. The overall image quality produced by low-field MRI systems, although perhaps somewhat inferior to 1.5-3 T MRI systems in terms of SNR, is nevertheless diagnostic for a broad variety of body imaging applications. Effective low-field body MRI requires (a) an understanding of the trade-offs resulting from lower field strengths, (b) an approach to modifying routine sequences to overcome SNR challenges, and (c) a workflow for carefully selecting appropriate patients. The authors describe the rationale, opportunities, and challenges of low-field body MRI; discuss important considerations for low-field imaging with common body MRI sequences; and delineate a variety of use cases for low-field body MRI. The authors also include lessons learned from their preliminary experience with a new low-field MRI system at a tertiary care center. Finally, they explore the future of low-field MRI, summarizing current limitations and potential future developments that may enhance the clinical adoption of this technology. ©RSNA, 2023 Supplemental material is available for this article. Quiz questions for this article are available through the Online Learning Center. See the invited commentary by Venkatesh in this issue.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Segurança do Paciente
5.
Radiographics ; 43(8): e230006, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37410624

RESUMO

Fluorine 18-fluorodeoxyglucose (FDG) PET and MRI independently play a valuable role in the management of patients with gynecologic malignancies, particularly endometrial and cervical cancer. The PET/MRI hybrid imaging technique combines the metabolic information obtained from PET with the excellent soft-tissue resolution and anatomic details provided by MRI in a single examination. MRI is the modality of choice for assessment of local tumor extent in the pelvis, whereas PET is used to assess for local-regional spread and distant metastases. The authors discuss the added value of FDG PET/MRI in imaging gynecologic malignancies of the pelvis, with a focus on the role of FDG PET/MRI in diagnosis, staging, assessing treatment response, and characterizing complications. PET/MRI allows better localization and demarcation of the extent of disease, characterization of lesions and involvement of adjacent organs and lymph nodes, and improved differentiation of benign from malignant tissues, as well as detection of the presence of distant metastasis. It also has the advantages of decreased radiation dose and a higher signal-to-noise ratio of a prolonged PET examination of the pelvis contemporaneous with MRI. The authors provide a brief technical overview of PET/MRI, highlight how simultaneously performed PET/MRI can improve stand-alone MRI and PET/CT in gynecologic malignancies, provide an image-rich review to illustrate practical and clinically relevant applications of this imaging technique, and review common pitfalls encountered in clinical practice. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Assuntos
Fluordesoxiglucose F18 , Neoplasias dos Genitais Femininos , Feminino , Humanos , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
6.
Radiographics ; 43(1): e220034, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36490210

RESUMO

Urinary bladder masses are commonly encountered in clinical practice, with 95% arising from the epithelial layer and rarer tumors arising from the lamina propria, muscularis propria, serosa, and adventitia. The extent of neoplastic invasion into these bladder layers is assessed with multimodality imaging, and the MRI-based Vesical Imaging Reporting and Data System is increasingly used to aid tumor staging. Given the multiple layers and cell lineages, a diverse array of pathologic entities can arise from the urinary bladder, and distinguishing among benign, malignant, and nonneoplastic entities is not reliably feasible in most cases. Pathologic assessment remains the standard of care for classification of bladder masses. Although urothelial carcinoma accounts for most urinary bladder malignancies in the United States, several histopathologic entities exist, including squamous cell carcinoma, adenocarcinoma, melanoma, and neuroendocrine tumors. Furthermore, there are variant histopathologic subtypes of urothelial carcinoma (eg, the plasmacytoid variant), which are often aggressive. Atypical benign bladder masses are diverse and can have inflammatory or iatrogenic causes and mimic malignancy. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Carcinoma de Células de Transição , Anormalidades do Sistema Digestório , Doenças da Bexiga Urinária , Neoplasias da Bexiga Urinária , Humanos , Carcinoma de Células de Transição/patologia , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Bexiga Urinária/diagnóstico por imagem , Estadiamento de Neoplasias
7.
Radiographics ; 43(7): e220209, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37319026

RESUMO

Small solid renal masses (SRMs) are frequently detected at imaging. Nearly 20% are benign, making careful evaluation with MRI an important consideration before deciding on management. Clear cell renal cell carcinoma (ccRCC) is the most common renal cell carcinoma subtype with potentially aggressive behavior. Thus, confident identification of ccRCC imaging features is a critical task for the radiologist. Imaging features distinguishing ccRCC from other benign and malignant renal masses are based on major features (T2 signal intensity, corticomedullary phase enhancement, and the presence of microscopic fat) and ancillary features (segmental enhancement inversion, arterial-to-delayed enhancement ratio, and diffusion restriction). The clear cell likelihood score (ccLS) system was recently devised to provide a standardized framework for categorizing SRMs, offering a Likert score of the likelihood of ccRCC ranging from 1 (very unlikely) to 5 (very likely). Alternative diagnoses based on imaging appearance are also suggested by the algorithm. Furthermore, the ccLS system aims to stratify which patients may or may not benefit from biopsy. The authors use case examples to guide the reader through the evaluation of major and ancillary MRI features of the ccLS algorithm for assigning a likelihood score to an SRM. The authors also discuss patient selection, imaging parameters, pitfalls, and areas for future development. The goal is for radiologists to be better equipped to guide management and improve shared decision making between the patient and treating physician. © RSNA, 2023 Quiz questions for this article are available in the supplemental material. See the invited commentary by Pedrosa in this issue.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Carcinoma de Células Renais/diagnóstico , Neoplasias Renais/patologia , Imageamento por Ressonância Magnética/métodos , Diagnóstico Diferencial , Estudos Retrospectivos
8.
J Magn Reson Imaging ; 55(6): 1890-1899, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34704644

RESUMO

BACKGROUND: Although studies have described factors associated with failed magnetic resonance elastography (MRE), little is known about what factors influence usable elastography data. PURPOSE: To identify factors that have a negative impact on percent measurable liver volume (pMLV), defined as the proportion of usable liver elastography data relative to the volume of imaged liver in patients undergoing MRE. STUDY TYPE: Retrospective. SUBJECTS: A total of 264 patients (n = 132 males, n = 132 females; mean age = 57 years) with suspected or known chronic liver disease underwent MRE paired with a liver protocol MRI. FIELD STRENGTH/SEQUENCE: MRE was performed on a single 1.5 T scanner using a two-dimensional gradient-recalled echo phase-contrast sequence with a passive acoustic driver overlying the right hemiliver. ASSESSMENT: Stiffness maps (usable data at 95% confidence) and liver contours on magnitude images of the MRE acquisition were manually traced and used to assess mean stiffness and pMLV. Hepatic fat fraction and R2 * values were also calculated. The distance from the acoustic wave generator on the skin surface to the liver edge was measured. Two radiologists performed the MR analyses with 50 overlapping cases for inter-reader analysis. STATISTICAL TESTS: Linear regression was performed to identify factors significantly associated with pMLV. Intraclass correlation was performed for inter-reader reliability. RESULTS: pMLV was 31% ± 20% (range 0%-86%). Complete MRE failure (i.e. pMLV = 0%) occurred in 10 patients (4%). Multivariate linear regression identified higher hepatic fat fraction, R2 *, BMI, and driver-to-liver surface distance; male sex; and lower mean liver stiffness was significantly independently associated with lower pMLV. Intraclass correlation for pMLV was 0.96, suggestive of excellent reliability. DATA CONCLUSION: Higher fat fraction, R2 *, BMI, driver-to-liver surface distance, male sex, and lower mean liver stiffness were associated with lower pMLV. Optimization of image acquisition parameters and driver placement may improve MRE quality, and pMLV likely serves as a diagnostic utility quality control metric. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
J Clin Gastroenterol ; 56(5): 457-463, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33883512

RESUMO

GOALS: No established methods exist to predict who will require a higher number of endoscopic necrosectomy sessions for walled-off necrosis (WON). We aim to identify radiologic predictors for requiring a greater number of necrosectomy sessions. This may help to identify patients who benefit from aggressive endoscopic management. MATERIALS AND METHODS: This is a multicenter retrospective study of patients with WON at 3 tertiary care centers. WON characteristics on preintervention computed tomography imaging were evaluated to determine if they were predictive of requiring more endoscopic necrosectomy. RESULTS: A total of 104 patients were included. Seventy patients (67.3%) underwent endoscopic necrosectomy, with median of 2 necrosectomies. WON largest transverse diameters (P=0.02), largest coronal diameters (P=0.01), necrosis pattern [likelihood ratio (LR)=17.85, P<0.001], spread (LR=11.02, P=0.01), hemorrhage (LR=8.64, P=0.003), and presence of disconnected pancreatic duct (LR=6.80, P=0.01) were associated with undergoing ≥2 necrosectomies. Patients with septations/loculations were significantly less likely to undergo ≥2 necrosectomies (LR=4.86, P=0.03). CONCLUSIONS: Several computed tomography radiologic features were significantly associated with undergoing ≥2 necrosectomies. These could help identify patients who will undergo a higher number of endoscopic necrosectomy sessions.


Assuntos
Pancreatite Necrosante Aguda , Drenagem/métodos , Endoscopia/métodos , Humanos , Necrose/complicações , Pancreatite Necrosante Aguda/diagnóstico por imagem , Pancreatite Necrosante Aguda/cirurgia , Estudos Retrospectivos , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
Radiographics ; 42(7): 2054-2074, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36112522

RESUMO

Body MRI has evolved from a niche subspecialty to a standard modality in the practice of abdominal radiology. However, the practicing radiologist may feel uncomfortable interpreting body MRI studies owing to a lack of case volume and inconsistent exposure. The authors highlight teaching points and subtleties central to better acquisition and interpretation of body MRI studies. Appropriate contrast agent selection and arterial phase acquisition timing provide greater diagnostic certainty in answering common clinical questions at liver MRI, such as assessing cirrhosis and evaluating focal liver lesions. Clinically relevant artifacts and physiologic phenomena, such as magnetic susceptibility and transient hepatic intensity difference, must be recognized and appropriately used when reading a study. Fat within organs and lesions is commonly encountered at body MRI. The authors discuss the nuances of common and uncommon entities, how to address fat suppression failure, assessment of bone marrow at body MRI, and an organized approach to fat-containing renal and adrenal masses. Motion artifacts are more commonly encountered at body MRI than at MRI of other anatomic regions, and understanding the various techniques, their benefits, and trade-offs will aid the body imager in protocol design and moving beyond "nondiagnostic" examinations. Challenging anatomic sites to evaluate at body MRI are reviewed. Finally, the authors offer tips for accurate interpretation of diffusion-weighted imaging, hepatobiliary phase imaging, and posttreatment imaging studies. By reviewing this article, the abdominal imager will be better prepared to perform and interpret body MRI studies confidently and accurately. An invited commentary by Kalb is available online. Online supplemental material is available for this article. ©RSNA, 2022.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Fígado/patologia
11.
Radiology ; 299(2): 349-358, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33754826

RESUMO

Background Conventional radiologic modalities perform poorly in the radiated rectum and are often unable to differentiate residual cancer from treatment scarring. Purpose To report the development and initial patient study of an imaging system comprising an endorectal coregistered photoacoustic (PA) microscopy (PAM) and US system paired with a convolution neural network (CNN) to assess the rectal cancer treatment response. Materials and Methods In this prospective study (ClinicalTrials.gov identifier NCT04339374), participants completed radiation and chemotherapy from September 2019 to September 2020 and images were obtained with the PAM/US system prior to surgery. Another group's colorectal specimens were studied ex vivo. The PAM/US system consisted of an endorectal imaging probe, a 1064-nm laser, and one US ring transducer. The PAM CNN and US CNN models were trained and validated to distinguish normal from malignant colorectal tissue using ex vivo and in vivo patient data. The PAM CNN and US CNN were then tested using additional in vivo patient data that had not been seen by the CNNs during training and validation. Results Twenty-two patients' ex vivo specimens and five patients' in vivo images (a total of 2693 US regions of interest [ROIs] and 2208 PA ROIs) were used for CNN training and validation. Data from five additional patients were used for testing. A total of 32 participants (mean age, 60 years; range, 35-89 years) were evaluated. Unique PAM imaging markers of the complete tumor response were found, specifically including recovery of normal submucosal vascular architecture within the treated tumor bed. The PAM CNN model captured this recovery process and correctly differentiated these changes from the residual tumor. The imaging system remained highly capable of differentiating tumor from normal tissue, achieving an area under the receiver operating characteristic curve of 0.98 (95% CI: 0.98, 0.99) for data from five participants. By comparison, the US CNN had an area under the receiver operating characteristic curve of 0.71 (95% CI: 0.70, 0.73). Conclusion An endorectal coregistered photoacoustic microscopy/US system paired with a convolutional neural network model showed high diagnostic performance in assessing the rectal cancer treatment response and demonstrated potential for optimizing posttreatment management. © RSNA, 2021 Supplemental material is available for this article. See also the editorial by Klibanov in this issue.


Assuntos
Aprendizado Profundo , Neoplasia Residual/diagnóstico por imagem , Técnicas Fotoacústicas , Neoplasias Retais/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Neoplasias Retais/patologia , Neoplasias Retais/terapia
12.
AJR Am J Roentgenol ; 216(5): 1229-1239, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33729883

RESUMO

OBJECTIVE. The purpose of this article was to assess the reliability and accuracy of hepatic periportal space widening and other qualitative imaging features for the prediction of hepatic fibrosis. MATERIALS AND METHODS. This single-center retrospective study identified consecutive patients who had undergone liver MR elastography. Two abdominal radiologists independently reviewed anatomic images, assessing multiple qualitative features of chronic liver disease (CLD) including periportal space widening. Each reader also measured the periportal space at the main portal vein (MPV) and right portal vein (RPV). Interrater reliability analysis was then performed. Sensitivity and specificity were determined for the detection of any hepatic fibrosis (stage I or higher) and of advanced fibrosis (stage III or higher) using stiffness on MR elastography as the reference standard. RESULTS. Of 229 subjects, 157 (69%) had fibrosis and 78 (34%) had advanced fibrosis. Agreement for periportal space widening was moderate (κ = 0.47), and agreement for remaining features was moderate to substantial (κ = 0.42-0.80). Agreement for the periportal space at the MPV was moderate (ICC, 0.55), and agreement for the periportal space at the RPV was near perfect (ICC, 0.83). Periportal space widening had the highest sensitivity (83.0%) for any fibrosis, with limited specificity (61.3%). Surface nodularity had the highest specificity (94.4%) for any fibrosis, with limited sensitivity (51.6%). Periportal space widening plus one or more additional imaging feature of CLD or the presence of surface nodularity alone had sensitivity of 72.6% and specificity of 76.1%. A periportal space at the MPV greater than 9.5 mm had substantial agreement with qualitative periportal space widening (κ = 0.74). CONCLUSION. Periportal space widening has a high sensitivity for hepatic fibrosis, with moderate specificity when combined with additional anatomic features of CLD.


Assuntos
Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
13.
AJR Am J Roentgenol ; 217(3): 633-643, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33025806

RESUMO

Hepatic arterial infusion (HAI) of chemotherapy is a locoregional treatment strategy for hepatic malignancy involving placement of a surgically implanted pump or percutaneous port-catheter device into a branch of the hepatic artery. HAI has been used for metastatic colorectal cancer for decades but has recently attracted new attention because of its potential impact on survival, when combined with systemic therapy, in patients presenting with unresectable hepatic disease. Although various HAI device-related complications have been described, little attention has been given to their appearance on imaging. Radiologists are uniquely positioned to identify these complications given that patients receiving HAI therapy typically undergo frequent imaging and may have complications that are delayed or clinically unsuspected. Therefore, this article reviews the multimodality imaging considerations of surgically implanted HAI devices. The role of imaging in routine perioperative assessment, including the normal postoperative appearance of the device, is described. The imaging findings of potential complications, including pump pocket complications, catheter or arterial complications, and toxic or ischemic complications, are presented, with a focus on CT. Familiarity with the device and its complications will aid radiologists in playing an important role in the treatment of patients undergoing HAI therapy.


Assuntos
Artéria Hepática/diagnóstico por imagem , Artéria Hepática/cirurgia , Bombas de Infusão Implantáveis , Neoplasias Hepáticas/tratamento farmacológico , Tomografia Computadorizada por Raios X/métodos , Humanos , Infusões Intra-Arteriais , Radiografia
14.
Radiographics ; 41(5): 1549-1568, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34297630

RESUMO

The vagina is a median fibromuscular structure of the female reproductive system that extends from the vulva inferiorly to the uterine cervix superiorly. As most vaginal lesions are detected at gynecologic examination, imaging performed for nongynecologic indications can frequently cause concomitant vaginal pathologic conditions to be overlooked. The vagina is often underevaluated at routinely performed pelvic transvaginal US because of a narrow scan area and probe positioning. MRI has progressively become the imaging method of choice for vaginal pathologic conditions, as it provides excellent soft-tissue detail with unparalleled delineation of the complex pelvic floor anatomy and helps establish a diagnosis for most vaginal diseases. It is important that radiologists use a focused approach toward understanding and correctly recognizing different vaginal entities that may otherwise go unnoticed. In this case-based review, the authors discuss the key imaging features of wide-ranging vaginal pathologic conditions, with emphasis on appearance at MRI. Knowledge of vaginal anatomy and embryology is helpful in evaluating congenital anomalies at imaging. Often seen incidentally, vaginal inflammation can cause diagnostic confusion. Because of its central location in the pelvis, the vagina can form fistulas to the urinary bladder, colon, rectum, or anus. Vaginal masses can be neoplastic and nonneoplastic and include a myriad of benign and malignant conditions, some of which have characteristic imaging features. Therapeutic and nontherapeutic vaginal foreign bodies include pessaries, vaginal mesh, and packing that can be seen with or without associated complications. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Imageamento por Ressonância Magnética , Vagina , Colo do Útero , Feminino , Humanos , Reto , Bexiga Urinária , Vagina/diagnóstico por imagem
15.
Radiographics ; 41(4): 1123-1143, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34048278

RESUMO

The genitourinary region is one of the most common sites of extrapulmonary tuberculosis (TB) involvement. The imaging features of genitourinary TB are protean and can mimic other entities, including malignancy, and pose a diagnostic dilemma. Hematogenous seeding and lymphatic spread of mycobacteria from pulmonary, tonsillar, and nodal TB are implicated in the pathogenesis of genitourinary TB. In addition, contiguous extension from the urinary tract and sexual transmission are described as sources of genital TB. Genitourinary TB can be indolent and results in nonspecific signs and symptoms; thus, imaging has a vital role in the working diagnosis for these cases. Classic uroradiologic signs of genitourinary TB are primarily described from the era of intravenous urography and conventional radiography. Now, CT, CT urography, MRI, and US are used in the diagnosis and management. Familiarity with the imaging features of genitourinary TB may help guide the diagnosis and, in turn, lead to timely management. US has a vital role in the evaluation of scrotal and female genital TB. MRI offers superior soft-tissue contrast resolution and excellent depiction of anatomic detail. The various imaging manifestations of genitourinary TB are highlighted. ©RSNA, 2021.


Assuntos
Tuberculose Urogenital , Tuberculose , Feminino , Humanos , Imageamento por Ressonância Magnética , Radiografia , Tuberculose/diagnóstico por imagem , Tuberculose Urogenital/diagnóstico por imagem , Urografia
16.
J Magn Reson Imaging ; 52(2): 325-347, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32061029

RESUMO

Magnetic resonance angiography (MRA) is a powerful clinical tool for evaluation of the thoracic vasculature. MRA can be performed on nearly any magnetic resonance imaging (MRI) scanner, and provides images of high diagnostic quality without the use of ionizing radiation. While computed tomographic angiography (CTA) is preferred in the evaluation of hemodynamically unstable patients, MRA represents an important tool for evaluation of the thoracic vasculature in stable patients. Contrast-enhanced MRA is generally performed unless there is a specific contraindication, as it shortens the duration of the exam and provides images of higher diagnostic quality than noncontrast MRA. However, intravenous contrast is often not required to obtain a diagnostic evaluation for most clinical indications. Indeed, a variety of noncontrast MRA techniques are used for thoracic imaging, often in conjunction with contrast-enhanced MRA, each of which has a differing degree of reliance on flowing blood to produce the desired vascular signal. In this article we review contrast-enhanced MRA, with a focus on contrast agents, methods of bolus timing, and considerations in imaging acquisition. Next, we cover the mechanism of contrast, strengths, and weaknesses of various noncontrast MRA techniques. Finally, we present an approach to protocol development and review representative protocols used at our institution for a variety of thoracic applications. Further attention will be devoted to additional techniques employed to address specific clinical questions, such as delayed contrast-enhanced imaging, provocative maneuvers, electrocardiogram and respiratory gating, and phase-contrast imaging. The purpose of this article is to review basic techniques and methodology in thoracic MRA, discuss an approach to protocol development, and illustrate commonly encountered pathology on thoracic MRA examinations. Level of Evidence 5 Technical Efficacy Stage 3.


Assuntos
Meios de Contraste , Angiografia por Ressonância Magnética , Angiografia por Tomografia Computadorizada , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
17.
Eur Radiol ; 30(2): 996-1007, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31654212

RESUMO

OBJECTIVES: To determine whether the LI-RADS imaging features of primary liver carcinomas (PLCs) other than hepatocellular carcinoma (non-HCC PLCs) differ between patients considered high risk (RF+) versus not high risk (RF-) for HCC and to compare rates of miscategorization as probable or definite HCC between the RF+ and RF- populations. METHODS: This retrospective study included all pathology-proven non-HCC PLCs imaged with liver-protocol CT or MRI from 2007 to 2017 at two liver transplant centers. Patients were defined per LI-RADS v2018 criteria as RF+ or RF-. Two independent, blinded readers (R1, R2) categorized 265 lesions using LI-RADS v2018. Logistic regression was utilized to assess for differences in imaging feature frequencies between RF+ and RF- patients. Fisher's exact test was used to assess for differences in miscategorization rates. RESULTS: Non-HCC PLCs were significantly more likely to exhibit nonrim arterial phase hyperenhancement (R1: OR = 2.94; R2: OR = 7.09) and nonperipheral "washout" (R1: OR = 3.65; R2: OR = 7.69) but significantly less likely to exhibit peripheral "washout" (R1: OR = 0.30; R2: OR = 0.10) and delayed central enhancement (R1: OR = 0.18; R2: OR = 0.25) in RF+ patients relative to RF- patients. Consequently, non-HCC PLCs were more often miscategorized as probable or definite HCC in RF+ versus RF- patients (R1: 23.3% vs. 3.6%, p < 0.001; R2: 11.0% vs. 2.6%, p = 0.009). CONCLUSIONS: Non-HCC PLCs are more likely to mimic HCCs on CT and MRI in the LI-RADS target population than in patients without LI-RADS-defined HCC risk factors. KEY POINTS: • The presence of LI-RADS-defined risk factors for HCC tends to alter the imaging appearances of non-HCC PLCs, resulting in higher frequencies of major features and lower frequencies of LR-M features. • Non-HCC PLCs are more likely to be miscategorized as probable or definite HCC in the LI-RADS target population than in patients without LI-RADS-defined HCC risk factors.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Idoso , Carcinoma Hepatocelular/patologia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Hepáticas/patologia , Modelos Logísticos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Método Simples-Cego , Tomografia Computadorizada por Raios X/métodos
18.
AJR Am J Roentgenol ; 214(1): 114-121, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31573857

RESUMO

OBJECTIVE. Small renal masses (< 4 cm) can be difficult to accurately classify as benign or malignant, particularly when they appear T1 hyperintense on MRI. This intrinsic signal, potentially related to intralesional hemorrhage, may limit evaluation of signal intensity on DWI. The purpose of this study was to test whether apparent diffusion coefficient (ADC) measurements may distinguish malignancy. MATERIALS AND METHODS. This single-center retrospective study identified patients with a T1-hyperintense renal mass less than 4 cm on MRI. Malignant lesions were pathologically proven; a benign mass was established by a predefined hierarchy of pathologic proof, follow-up ultrasound, or follow-up imaging showing more than 5 years of stability. T1 hyperintensity, defined as a signal intensity equivalent to or greater than the adjacent renal cortex, was confirmed by a senior abdominal radiologist. Two additional abdominal radiologists independently measured ADC of the lesion, which was normalized to the ADC of the background ipsilateral kidney and represented as ADCratio. RESULTS. The final cohort included 58 benign and 37 malignant renal lesions in 95 patients. Interrater agreement for ADC measurements was almost perfect (κ = 0.836-0.934). ADCratio was significantly lower in malignant compared with benign lesions (0.65 ± 0.29 vs 1.03 ± 0.32; p < 0.001). Malignant lesions were significantly larger than benign lesions (2.66 ± 0.86 cm vs 1.50 ± 0.65 cm; p < 0.001); however, after controlling for lesion size, ADCratio remained a significant predictor of malignancy (p < 0.001). CONCLUSION. ADCratio was highly reproducible for T1-hyperintense small renal masses and was significantly lower in malignant compared with benign renal masses.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias Renais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Carga Tumoral , Adulto Jovem
19.
Radiographics ; 40(3): 731-753, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32302263

RESUMO

Intra-abdominal calcifications are common. Multiple pathologic processes manifest within the abdomen and pelvis in association with calcifications, which can be benign, premalignant, or malignant. Although calcium deposition in the abdomen can occur secondary to various mechanisms, the most common cau se is cellular injury that leads to dystrophic calcifications. The authors provide a summary of various common and uncommon calcifications in the abdomen and pelvis, primarily using location to illuminate diagnostic significance. Six broad categories of calcifications in the abdomen and pelvis are recognized: mesenteric, peritoneal, retroperitoneal, organ-based, vascular, and musculoskeletal. In addition to site, the various patterns and morphology of calcifications encountered in various conditions can be helpful for diagnosis, especially those depicted on radiographs. For example, some patterns diagnostic for various conditions include round or oval stones in the biliary or urothelial tracts, curvilinear calcifications associated with cysts or neoplasms, and sheetlike calcifications along peritoneal surfaces in the setting of chronic peritoneal dialysis or metastatic disease. Organ encrustation with calcium may be a premalignant finding (eg, porcelain gallbladder). In addition, the development of calcium after initiation of treatment can be used as an indicator of response in conditions such as tuberculosis, lymphoma, and hydatid disease. As calcifications are almost invariably detected at imaging, it is imperative for radiologists to be aware of their diagnostic implications and use the presence of calcification in an organ, mass, or other anatomic location for problem solving. ©RSNA, 2020.


Assuntos
Cavidade Abdominal/diagnóstico por imagem , Neoplasias Abdominais/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Pelve/diagnóstico por imagem , Diagnóstico Diferencial , Humanos
20.
Radiology ; 290(1): 23-30, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30511906

RESUMO

As radiologic technology advances, quantitative imaging is becoming more prevalent in clinical practice. This article reviews quantitative hepatic MRI, specifically involving fat and iron deposition, by demonstrating how they were iteratively improved. These iterative improvements involved incorporating more knowledge about the physiology of liver disease and MRI physics to reduce the adverse effects caused by confounding factors. The relevant foundations of MRI physics and liver pathophysiology are briefly reviewed, followed by the various improvements made by expanding on this foundational knowledge. Results from the literature are then discussed within this context, validating the improvement of these resultant methods into clinically robust and useful techniques. Fibrosis quantification, which has been more difficult to robustly perform in clinical practice, is similarly reviewed in an online appendix, with proposals for future multiparametric directions to improve performance on the basis of the insights gained from fat and iron quantification in the liver.


Assuntos
Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA