Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Anal Chem ; 90(4): 2891-2895, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29345134

RESUMO

Primary cilia are hair-like sensory organelles whose dimensions and location vary with cell type and culture condition. Herein, we employed scanning ion conductance microscopy (SICM) to visualize the topography of primary cilia from different cell types. By combining SICM with fluorescence imaging, we successfully distinguished between surface cilia that project outward from the cell surface and subsurface cilia that are trapped below it. The nanoscale structure of the ciliary pocket, which cannot be easily identified using a confocal fluorescence microscope, was observed in SICM images. Furthermore, we developed a topographic reconstruction method using current-distance profiles to evaluate the relationship between set point and topographic image and found that a low set point is important for detecting the true topography of a primary cilium using hopping mode SICM.


Assuntos
Cílios/química , Microscopia Eletroquímica de Varredura , Nanopartículas/química , Imagem Óptica , Animais , Células Cultivadas , Cães , Humanos , Células Madin Darby de Rim Canino , Camundongos , Microscopia Confocal , Microscopia de Fluorescência , Células NIH 3T3 , Tamanho da Partícula
2.
Proc Natl Acad Sci U S A ; 109(29): 11540-5, 2012 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-22611191

RESUMO

We describe voltage-switching mode scanning electrochemical microscopy (VSM-SECM), in which a single SECM tip electrode was used to acquire high-quality topographical and electrochemical images of living cells simultaneously. This was achieved by switching the applied voltage so as to change the faradaic current from a hindered diffusion feedback signal (for distance control and topographical imaging) to the electrochemical flux measurement of interest. This imaging method is robust, and a single nanoscale SECM electrode, which is simple to produce, is used for both topography and activity measurements. In order to minimize the delay at voltage switching, we used pyrolytic carbon nanoelectrodes with 6.5-100 nm radii that rapidly reached a steady-state current, typically in less than 20 ms for the largest electrodes and faster for smaller electrodes. In addition, these carbon nanoelectrodes are suitable for convoluted cell topography imaging because the RG value (ratio of overall probe diameter to active electrode diameter) is typically in the range of 1.5-3.0. We first evaluated the resolution of constant-current mode topography imaging using carbon nanoelectrodes. Next, we performed VSM-SECM measurements to visualize membrane proteins on A431 cells and to detect neurotransmitters from a PC12 cells. We also combined VSM-SECM with surface confocal microscopy to allow simultaneous fluorescence and topographical imaging. VSM-SECM opens up new opportunities in nanoscale chemical mapping at interfaces, and should find wide application in the physical and biological sciences.


Assuntos
Diagnóstico por Imagem/métodos , Técnicas Eletroquímicas/métodos , Microscopia de Varredura por Sonda/métodos , Nanoestruturas/química , Animais , Linhagem Celular Tumoral , Eletrodos , Fluorescência , Humanos , Células PC12 , Ratos , Fatores de Tempo
3.
J Mol Cell Cardiol ; 67: 38-48, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24345421

RESUMO

The purpose of this study was to investigate whether caveolin-3 (Cav3) regulates localization of ß2-adrenergic receptor (ß2AR) and its cAMP signaling in healthy or failing cardiomyocytes. We co-expressed wildtype Cav3 or its dominant-negative mutant (Cav3DN) together with the Förster resonance energy transfer (FRET)-based cAMP sensor Epac2-camps in adult rat ventricular myocytes (ARVMs). FRET and scanning ion conductance microscopy were used to locally stimulate ß2AR and to measure cytosolic cAMP. Cav3 overexpression increased the number of caveolae and decreased the magnitude of ß2AR-cAMP signal. Conversely, Cav3DN expression resulted in an increased ß2AR-cAMP response without altering the whole-cell L-type calcium current. Following local stimulation of Cav3DN-expressing ARVMs, ß2AR response could only be generated in T-tubules. However, the normally compartmentalized ß2AR-cAMP signal became diffuse, similar to the situation observed in heart failure. Finally, overexpression of Cav3 in failing myocytes led to partial ß2AR redistribution back into the T-tubules. In conclusion, Cav3 plays a crucial role for the localization of ß2AR and compartmentation of ß2AR-cAMP signaling to the T-tubules of healthy ARVMs, and overexpression of Cav3 in failing myocytes can partially restore the disrupted localization of these receptors.


Assuntos
Caveolina 3/metabolismo , Simulação por Computador , AMP Cíclico/metabolismo , Miócitos Cardíacos/metabolismo , Receptores Adrenérgicos beta 2/metabolismo , Transdução de Sinais , Animais , Western Blotting , Caveolina 3/genética , Síndromes Compartimentais/fisiopatologia , Expressão Gênica , Insuficiência Cardíaca/fisiopatologia , Ratos
4.
Nat Methods ; 6(4): 279-81, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19252505

RESUMO

We describe hopping mode scanning ion conductance microscopy that allows noncontact imaging of the complex three-dimensional surfaces of live cells with resolution better than 20 nm. We tested the effectiveness of this technique by imaging networks of cultured rat hippocampal neurons and mechanosensory stereocilia of mouse cochlear hair cells. The technique allowed examination of nanoscale phenomena on the surface of live cells under physiological conditions.


Assuntos
Células Cultivadas/ultraestrutura , Microscopia de Varredura por Sonda/instrumentação , Microscopia de Varredura por Sonda/métodos , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Animais , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Íons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Am Chem Soc ; 132(29): 10118-26, 2010 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-20590117

RESUMO

We described a hybrid system of scanning electrochemical microscopy (SECM) and scanning ion conductance microscopy (SICM) with ion current feedback nanopositioning control for simultaneous imaging of noncontact topography and spatial distribution of electrochemical species. A nanopipette/nanoring electrode probe provided submicrometer resolution of the electrochemical measurement on surfaces with complex topology. The SECM/SICM probe had an aperture radius of 220 nm. The inner and outer radii of the SECM Au nanoring electrode were 330 and 550 nm, respectively. Characterization of the probe was performed with scanning electron microscopy (SEM), cyclic voltammetry (CV), and approach curve measurements. SECM/SICM was applied to simultaneous imaging of topography and electrochemical responses of enzymes (horse radish peroxidase (HRP) and glucose oxidase (GOD)) and single live cells (A6 cells, superior cervical ganglion (SCG) cells, and cardiac myocytes). The measurements revealed the distribution of activity of the enzyme spots on uneven surfaces with submicrometer resolution. SECM/SICM acquired high resolution topographic images of cells together with the map of electrochemical signals. This combined technique was also applied to the evaluation of the permeation property of electroactive species through cellular membranes.


Assuntos
Microscopia/métodos , Animais , Bovinos , Linhagem Celular , Permeabilidade da Membrana Celular , Sobrevivência Celular , Eletroquímica , Eletrodos , Glucose Oxidase/metabolismo , Peroxidase do Rábano Silvestre/metabolismo , Microscopia/instrumentação , Imagem Molecular , Análise Serial de Proteínas
6.
Biophys J ; 94(10): 4089-94, 2008 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-18199668

RESUMO

We have developed a high-resolution scanning surface confocal microscopy technique capable of imaging single virus-like particles (VLPs) on the surfaces of cells topographically and by fluorescence. The technique combines recently published single-molecule-resolution ion-conductance microscopy that acquires topographical data with confocal microscopy providing simultaneous fluorescent imaging. In our experiments we have demonstrated that the cell membrane exhibits numerous submicrometer-sized surface structures that could be topographically confused with virus particles. However, simultaneous acquisition of confocal images allows the positions of fluorescently tagged particles to be identified. Using this technique, we have, for the first time, visualized single polyoma VLPs adsorbed onto the cell membrane. Observed VLPs had a mean width of 108 +/- 16 nm. The particles were randomly distributed across the cell membrane, and no specific interactions were seen with cell membrane structures such as microvilli. These experiments demonstrate the utility of this new microscope for imaging the interactions of nanoparticles with the cell surface to provide novel insights into the earliest interactions of viruses and other nanoparticles such as gene therapy vectors with the cell.


Assuntos
Membrana Celular/ultraestrutura , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Microscopia Confocal/instrumentação , Vírion/ultraestrutura , Animais , Células COS , Chlorocebus aethiops , Desenho de Equipamento , Análise de Falha de Equipamento , Sensibilidade e Especificidade
7.
Biophys J ; 94(5): 1646-55, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18024498

RESUMO

Spatial distribution of maxi-anion channels in rat cardiomyocytes were studied by applying the recently developed patch clamp technique under scanning ion conductance microscopy, called the "smart-patch" technique. In primary-cultured neonatal cells, the channel was found to be unevenly distributed over the cell surface with significantly lower channel activity in cellular extensions compared with the other parts. Local ATP release, detected using a PC12 cell-based biosensor technique, also exhibited a similar pattern. The maxi-anion channel activity could not be detected in freshly isolated adult cardiomyocytes by the conventional patch-clamp with 2-MOmega pipettes. However, when fine-tipped 15-20 MOmega pipettes were targeted to only Z-line areas, we observed, for the first time, the maxi-anion events. Smart-patching different regions of the cell surface, we found that the channel activity was maximal at the openings of T-tubules and along Z-lines, but was significantly decreased in the scallop crest area. Thus, it is concluded that maxi-anion channels are concentrated at the openings of T-tubules and along Z-lines in adult cardiomyocytes. This study showed that the smart-patch technique provides a powerful method to detect a unitary event of channels that are localized at some specific site in the narrow region.


Assuntos
Membrana Celular/metabolismo , Canais Iônicos/análise , Canais Iônicos/metabolismo , Miócitos Cardíacos/metabolismo , Técnicas de Patch-Clamp/métodos , Potenciais de Ação/fisiologia , Trifosfato de Adenosina/metabolismo , Animais , Ânions , Transporte Biológico , Membrana Celular/ultraestrutura , Células Cultivadas , Canais Iônicos/ultraestrutura , Microscopia Eletrônica de Varredura/métodos , Miócitos Cardíacos/ultraestrutura , Células PC12 , Ratos , Ratos Wistar
9.
Tissue Eng ; 12(4): 657-64, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16674281

RESUMO

We report here the novel use of scanning ion conductance microscopy (SICM) to produce surface images of embryonic stem cell-derived cardiomyocytes (ESCM) to identify individual contracting cardiomyocytes among different cell types. By measuring amplitude and rhythm we can quantitate contraction of ESCM. This method gives, within the same experiment, an assessment of the number and position of ESCM within the layer of mixed cell types, as well as an accurate measure of the response of individual ESCM. Using different modulators of contraction as examples we showed how SICM could be used for recording their responses. We subsequently demonstrated that this model can be used to investigate the protective effect of antiarrhythmogenic drugs.


Assuntos
Embrião de Mamíferos/citologia , Células-Tronco Mesenquimais/citologia , Microscopia de Tunelamento , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/ultraestrutura , Animais , Antiarrítmicos/farmacologia , Técnicas de Cultura de Células , Diferenciação Celular , Linhagem Celular , Linhagem da Célula , Camundongos , Microscopia de Tunelamento/instrumentação , Microscopia de Tunelamento/métodos , Contração Miocárdica/efeitos dos fármacos , Miócitos Cardíacos/citologia , Miócitos Cardíacos/efeitos dos fármacos
11.
FEBS Lett ; 548(1-3): 74-8, 2003 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-12885410

RESUMO

Cardiac toxicity is an uncommon but potentially serious complication of cancer therapy, especially with anthracyclines. One of the most effective anticancer drugs is doxorubicin, but its value is limited by the risk of developing cardiomyopathy and ventricular arrhythmia. When applied to a network of periodically contracting cardiomyocytes in culture, doxorubicin induces rhythm disturbances. Using a novel rapid assay based on non-invasive ion-conductance microscopy we show that the beta-antagonist esmolol can restore rhythm in doxorubicin-treated cultures of cardiomyocytes. Moreover, esmolol pre-treatment can protect the culture from doxorubicin-induced arrhythmia.


Assuntos
Antiarrítmicos/farmacologia , Arritmias Cardíacas/tratamento farmacológico , Doxorrubicina/farmacologia , Miócitos Cardíacos/efeitos dos fármacos , Propanolaminas/farmacologia , Antagonistas Adrenérgicos beta/farmacologia , Animais , Animais Recém-Nascidos , Arritmias Cardíacas/induzido quimicamente , Técnicas de Cultura de Células/métodos , Antagonismo de Drogas , Modelos Cardiovasculares , Contração Miocárdica/efeitos dos fármacos , Miócitos Cardíacos/citologia , Ratos
12.
Mol Cell Endocrinol ; 217(1-2): 101-8, 2004 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-15134807

RESUMO

BACKGROUND: Continuous high spatial resolution observations of living A6 cells would greatly aid the elucidation of the relationship between structure and function and facilitate the study of major physiological processes such as the mechanism of action of aldosterone. Unfortunately, observing the micro-structural and functional changes in the membrane of living cells is still a formidable challenge for a microscopist. METHOD: Scanning ion conductance microscopy (SICM), which uses a glass nanopipette as a sensitive probe, has been shown to be suitable for imaging non-conducting surfaces bathed in electrolytes. A specialized version of this microscopy has been developed by our group and has been applied to image live cells at high-resolution for the first time. This method can also be used in conjunction with patch clamping to study both anatomy and function and identify ion channels in single cells. RESULTS: This new microscopy provides high-resolution images of living renal cells which are comparable with those obtained by scanning electron microscopy (SEM) and atomic force microscopy (AFM). Continuous 24h observations under normal physiological conditions showed how A6 kidney epithelial cells changed their height, volume, and reshaped their borders. The changes in cell area correlated with the density of microvilli on the surface. Surface microvilli density ranged from 0.5 microm(-2) for extended cells to 2.5 microm(2) for shrunk cells. Patch clamping of individual cells enabled anatomy and function to be correlated. CONCLUSIONS: Scanning ion conductance microscopy provides unique information about living cells that helps to understand cellular function. It has the potential to become a powerful tool for research on living renal cells.


Assuntos
Membrana Celular/ultraestrutura , Canais Iônicos/ultraestrutura , Microscopia de Tunelamento/métodos , Técnicas de Patch-Clamp/métodos , Animais , Linhagem Celular , Membrana Celular/metabolismo , Canais Iônicos/metabolismo , Xenopus laevis
13.
Nanomedicine (Lond) ; 8(5): 725-737, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23140503

RESUMO

AIM: To investigate the effect of surface charge of therapeutic nanoparticles on sarcolemmal ionic homeostasis and the initiation of arrhythmias. MATERIALS & METHODS: Cultured neonatal rat myocytes were exposed to 50 nm-charged polystyrene latex nanoparticles and examined using a combination of hopping probe scanning ion conductance microscopy, optical recording of action potential characteristics and patch clamp. RESULTS: Positively charged, amine-modified polystyrene latex nanoparticles showed cytotoxic effects and induced large-scale damage to cardiomyocyte membranes leading to calcium alternans and cell death. By contrast, negatively charged, carboxyl-modified polystyrene latex nanoparticles (NegNPs) were not overtly cytotoxic but triggered formation of 50-250-nm nanopores in the membrane. Cells exposed to NegNPs revealed pro-arrhythmic events, such as delayed afterdepolarizations, reduction in conduction velocity and pathological increment of action potential duration together with an increase in ionic current throughout the membrane, carried by the nanopores. CONCLUSION: The utilization of charged nanoparticles is a novel concept for targeting cardiac excitability. However, this unique nanoscopic investigation reveals an altered electrophysiological substrate, which sensitized the heart cells towards arrhythmias.


Assuntos
Arritmias Cardíacas/induzido quimicamente , Miócitos Cardíacos/efeitos dos fármacos , Nanopartículas/química , Nanopartículas/toxicidade , Potenciais de Ação/efeitos dos fármacos , Animais , Cálcio/metabolismo , Cardiotoxinas/química , Cardiotoxinas/metabolismo , Cardiotoxinas/toxicidade , Células Cultivadas , Miócitos Cardíacos/citologia , Nanopartículas/metabolismo , Técnicas de Patch-Clamp , Ratos
14.
Neuron ; 79(6): 1067-77, 2013 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-24050398

RESUMO

Direct electrical access to presynaptic ion channels has hitherto been limited to large specialized terminals such as the calyx of Held or hippocampal mossy fiber bouton. The electrophysiology and ion-channel complement of far more abundant small synaptic terminals (≤ 1 µm) remain poorly understood. Here we report a method based on superresolution scanning ion conductance imaging of small synapses in culture at approximately 100-150 nm 3D resolution, which allows presynaptic patch-clamp recordings in all four configurations (cell-attached, inside-out, outside-out, and whole-cell). Using this technique, we report presynaptic recordings of K(+), Na(+), Cl(-), and Ca(2+) channels. This semiautomated approach allows direct investigation of the distribution and properties of presynaptic ion channels at small central synapses.


Assuntos
Ativação do Canal Iônico/fisiologia , Canais Iônicos/fisiologia , Neurônios/citologia , Terminações Pré-Sinápticas/fisiologia , Animais , Animais Recém-Nascidos , Fenômenos Biofísicos/fisiologia , Cálcio/metabolismo , Células Cultivadas , Espinhas Dendríticas/fisiologia , Espinhas Dendríticas/ultraestrutura , Estimulação Elétrica , Eletrodos , Corantes Fluorescentes/metabolismo , Hipocampo/citologia , Imageamento Tridimensional , Canais Iônicos/ultraestrutura , Potenciais da Membrana/fisiologia , Microscopia de Tunelamento , Técnicas de Patch-Clamp , Terminações Pré-Sinápticas/ultraestrutura , Ratos
15.
J Cell Biol ; 197(4): 499-508, 2012 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-22564416

RESUMO

Current knowledge of the structural changes taking place during clathrin-mediated endocytosis is largely based on electron microscopy images of fixed preparations and x-ray crystallography data of purified proteins. In this paper, we describe a study of clathrin-coated pit dynamics in living cells using ion conductance microscopy to directly image the changes in pit shape, combined with simultaneous confocal microscopy to follow molecule-specific fluorescence. We find that 70% of pits closed with the formation of a protrusion that grew on one side of the pit, covered the entire pit, and then disappeared together with pit-associated clathrin-enhanced green fluorescent protein (EGFP) and actin-binding protein-EGFP (Abp1-EGFP) fluorescence. This was in contrast to conventionally closing pits that closed and cleaved from flat membrane sheets and lacked accompanying Abp1-EGFP fluorescence. Scission of both types of pits was found to be dynamin-2 dependent. This technique now enables direct spatial and temporal correlation between functional molecule-specific fluorescence and structural information to follow key biological processes at cell surfaces.


Assuntos
Clatrina/metabolismo , Invaginações Revestidas da Membrana Celular/metabolismo , Animais , Células COS , Chlorocebus aethiops , Clatrina/química , Dinamina II/metabolismo , Endocitose , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Microscopia
17.
Nanomedicine (Lond) ; 6(3): 565-75, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21542692

RESUMO

Cells naturally operate on the nanoscale level, with molecules combining together to form complex molecular machines, which can work together to enable normal cell function or go wrong as in the case of many diseases. Visualizing these key processes on the nanoscale has been difficult and two main approaches have been used to date; nanometer resolution imaging of fixed cells using electron microscopy, or imaging live cells using optical or fluorescence microscopy, with a resolution of a few hundred nanometers. Scanning probe microscopy has the potential to allow live cells to be imaged at nanoscale resolution and a noncontact method based on the use of a nanopipette probe has been developed over the last 10 years that allows both topographic and functional imaging. The rapid progress in this area of research over the last 4 years is reviewed in this article, which shows that imaging of complex cellular structures and tissues is now possible and that these methods are now sufficiently mature to provide new insights into important diseases.


Assuntos
Microscopia de Varredura por Sonda/instrumentação , Microscopia de Varredura por Sonda/métodos , Imagem Molecular , Nanotecnologia , Membrana Celular/ultraestrutura , Elasticidade , Transferência Ressonante de Energia de Fluorescência/métodos , Humanos , Pressão
18.
Pflugers Arch ; 456(1): 227-35, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18180951

RESUMO

We introduce a novel high resolution scanning surface confocal microscopy technique that enables imaging of endocytic pits in apical membranes of live cells for the first time. The improved topographical resolution of the microscope together with simultaneous fluorescence confocal detection produces pairs of images of cell surfaces sufficient to identify single endocytic pits. Whilst the precise position and size of the pit is detected by the ion conductance microscope, the molecular nature of the pit, e.g. clathrin coated or caveolae, is determined by the corresponding green fluorescent protein fluorescence. Also, for the first time, we showed that flotillin 1 and 2 can be found co-localising with approximately 200-nm indentations in the cell membrane that supports involvement of this protein in endocytosis.


Assuntos
Cavéolas/ultraestrutura , Endocitose/fisiologia , Microscopia Confocal/métodos , Microscopia de Varredura por Sonda/métodos , Animais , Células COS , Membrana Celular/metabolismo , Membrana Celular/ultraestrutura , Chlorocebus aethiops , Proteínas de Fluorescência Verde , Rim/citologia , Rim/ultraestrutura , Proteínas de Membrana/metabolismo , Proteínas de Membrana/ultraestrutura
19.
Clin Sci (Lond) ; 103(2): 191-200, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12149111

RESUMO

Obstetric cholestasis is characterized by raised bile acids, and can be complicated by intrauterine death. We have shown that the bile acid taurocholate causes loss of synchronous beating, bradycardia and cessation of contraction in cultured rat cardiomyocytes [Williamson, Gorelik, Eaton, Lab, de Swiet and Korchev (2001) Clin. Sci. 100, 363-369]. The aim of the present study was to investigate the effect of taurocholate on cardiomyocytes further. We demonstrated a reduced rate of contraction and proportion of beating cells when rat cardiomyocytes were exposed to increasing concentrations of taurocholate (0.1-3.0 mM); more marked at higher concentrations (P<0.001). Using scanning ion-conductance microscopy, we also demonstrated reduced amplitude of contraction and calcium transients with taurocholate. Our observations indicate that taurocholate affects calcium release from the sarcoplasmic reticulum and this parallels changes in contractile function. The relationship between the contraction amplitude and calcium transient is not linear, particularly at higher concentrations of taurocholate. We observed different effects in individual cultured neonatal cells; a reversible reduction in rate and amplitude of contraction in some, and irreversible oscillatory (fibrillatory) cessation of beating in others. The effects were more marked with higher concentrations. The contraction amplitude was also reduced in adult cardiomyocytes. The changes were reversible following removal of taurocholate in adult, but not in neonatal, cardiomyocytes exposed to higher concentrations (>0.3 mM) (P<0.001). In conclusion we have demonstrated that the bile acid taurocholate can cause different types of dysrhythmia in individual cardiomyocytes. These results provide further support for the hypothesis that obstetric cholestasis may produce cardiac-related sudden intrauterine death.


Assuntos
Cálcio/metabolismo , Colagogos e Coleréticos/farmacologia , Contração Miocárdica/efeitos dos fármacos , Miocárdio/metabolismo , Ácido Taurocólico/farmacologia , Animais , Tamanho Celular/efeitos dos fármacos , Células Cultivadas , Colestase/metabolismo , Feminino , Morte Fetal/etiologia , Humanos , Masculino , Modelos Animais , Gravidez , Complicações na Gravidez/metabolismo , Ratos , Ratos Sprague-Dawley
20.
J Am Chem Soc ; 124(30): 8810-1, 2002 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-12137530

RESUMO

We present a new, general method for the controlled deposition of biological molecules on surfaces, based on a nanopipet operating in ionic solution. The potential applied to the pipet tip controls the flux of biological molecules from the pipet, allowing fine control of the delivery rate. We used the ion current to control the distance of the pipet from the surface of a glass slide and deposited the fluorescently labeled DNA or protein G at a defined location onto the surface. Features of 830 nm size were obtained by depositing the biotinylated DNA onto a streptavidin surface; 1.3 mum size spots were obtained by depositing protein G onto a positively charged glass surface.


Assuntos
DNA de Cadeia Simples/química , Nanotecnologia/métodos , Proteínas do Tecido Nervoso/química , Fluorescência , Nanotecnologia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA