Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Vet Ophthalmol ; 25 Suppl 1: 103-110, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34784106

RESUMO

OBJECTIVE: To compare the measurements of iridocorneal angle parameters between spectral domain optical coherence tomography (SD-OCT) and ultrasound biomicroscopy (UBM) in dogs. ANIMALS STUDIED AND PROCEDURES: A total of 47 eyes of dogs were scanned at the temporal limbus using SD-OCT and UBM. Iridocorneal angle (ICA) and angle opening distance (AOD) were measured from the obtained images accordingly. The intra-observer and inter-observer reproducibility were evaluated using the intraclass correlation coefficient. To evaluate intra-observer reproducibility, measurements of the first and second grading from the first examiner were compared. To evaluate inter-observer reproducibility, measurements between the two examiners were compared. Agreement between ICA and AOD for SD-OCT and UBM was evaluated using Bland-Altman plots. RESULTS: In the first grading, the mean ICA and AOD for SD-OCT were 31.4 ± 6.4° and 641.4 ± 270.8 µm, respectively. The mean ICA and AOD for UBM were 32.0 ± 4.8° and 700.4 ± 238.8 µm, respectively. For ICA and AOD measurements, intra-observer reproducibility was excellent for both devices, whereas inter-observer reproducibility was excellent for SD-OCT and good for UBM. The mean difference in ICA between SD-OCT and UBM was 0.6° with a limit of agreement (LoA) span of 18.9°. The mean difference in AOD between SD-OCT and UBM was 58.9 µm with a LoA span of 804.4 µm. CONCLUSIONS: Spectral domain optical coherence tomography is an effective non-contact imaging modality for the evaluation of canine iridocorneal angle parameters in a clinical setting. Reproducibility of measurements obtained is comparable or superior to UBM, but values obtained by SD-OCT and UBM for AOD are not interchangeable between devices.


Assuntos
Microscopia Acústica , Tomografia de Coerência Óptica , Animais , Câmara Anterior/diagnóstico por imagem , Cães , Iris , Microscopia Acústica/métodos , Microscopia Acústica/veterinária , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/veterinária
2.
Vet Ophthalmol ; 25 Suppl 1: 96-102, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34784440

RESUMO

OBJECTIVE: To confirm the feasibility of visualizing upper and lower proximal lacrimal canaliculi (LC) using spectral-domain optical coherence tomography (SD-OCT). ANIMALS STUDIED: Eight eyes of four normal Beagle dogs. PROCEDURES: To obtain an upper proximal LC image, the head was turned in the opposite direction to the eye being imaged, and the medial part of the upper eyelid was everted to expose the LC. To obtain a lower LC image, the lower eyelid was everted just below the punctum. Using "angle mode", the scan line was placed parallel on the long axis of the LC. The inlet LC width (LCW) was measured. Artificial tears (AT) were instilled, and LCW was compared before and after AT instillation. Additionally, the return time to the initial LCW inlet width was recorded. RESULTS: Before AT instillation, there was a significant difference between the mean upper and lower LCW (91.8 ± 3.2 µm and 110.1 ± 8.4 µm, respectively). After AT instillation, the mean upper and lower LCW were 236.9 ± 27.7 µm and 238.4 ± 30.4 µm, respectively. Significant differences in the LCW before and after AT instillation in both the upper and lower LCWs were observed. The mean return time of the upper and lower LCW to their initial widths after AT instillation was within 4 min. CONCLUSIONS: Spectral-domain optical coherence tomography was an effective method for providing high-resolution images of the upper and lower proximal LC. This method enables observation of LC changes after instillation of eyedrops in veterinary clinical practice.


Assuntos
Aparelho Lacrimal , Tomografia de Coerência Óptica , Animais , Cães , Pálpebras , Aparelho Lacrimal/diagnóstico por imagem , Lubrificantes Oftálmicos , Lágrimas , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/veterinária
3.
Vet Ophthalmol ; 25 Suppl 1: 111-121, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34793607

RESUMO

OBJECTIVE: To evaluate the clinical application of spectral-domain optical coherence tomography (SD-OCT) for anterior uveitis in dogs. Animals and procedures Client-owned dogs presenting with anterior uveitis and clinically healthy dogs were enrolled in this study. Included eyes were divided into 5 groups by flare grade and 3 groups by cell grade through slit-lamp biomicroscopy. Each eye was examined using SD-OCT following slit-lamp biomicroscopy. The ratio of aqueous signal intensity to air signal intensity, which is called the aqueous-to-air relative intensity (ARI) index, was used to evaluate the flare grade. Cell number, central corneal thickness (CCT), and the presence of keratic precipitates (KPs) were analyzed on SD-OCT. The OCT parameters, including ARI index, cell number, and CCT, were compared to the slit-lamp clinical flare and cell grade. RESULTS: Thirty-six eyes with anterior uveitis and 27 healthy eyes were enrolled. The ARI index showed a significant correlation with clinical flare grade (rs  = 0.811, p < .001). In multiple regression analysis, the ARI index and CCT showed a significant negative correlation (r = -0.258, p = .044). The number of cells on SD-OCT significantly increased with cell grade on slit-lamp biomicroscopy (rs  = 0.653, p < .001). The clinical flare grade and CCT were significantly correlated in the partial correlation analysis after controlling for age (partial correlation coefficient = 0.471, p = .002). KPs were observed in 61% of the eyes with flare using SD-OCT (22/36 eyes). CONCLUSIONS: Spectral-domain optical coherence tomography could provide quantitative information, including the ARI index, cell counts, and CCT in dogs. SD-OCT is an auxiliary modality for slit-lamp biomicroscopy when evaluating anterior uveitis in dogs.


Assuntos
Doenças do Cão , Uveíte Anterior , Animais , Doenças do Cão/diagnóstico por imagem , Cães , Olho , Estudos de Viabilidade , Lâmpada de Fenda , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/veterinária , Uveíte Anterior/diagnóstico por imagem , Uveíte Anterior/veterinária
4.
Vet Ophthalmol ; 24(5): 460-468, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34402562

RESUMO

OBJECTIVE: To investigate the relationship between topical administration of flurbiprofen plus corticosteroids versus corticosteroids alone following phacoemulsification and the development of postoperative glaucoma in dogs. ANIMAL STUDIED: Thirty-eight/eighty-three (45.8%) eyes were prescribed topical flurbiprofen plus corticosteroids immediately postop while 45/83 (54.2%) eyes received topical corticosteroids alone. PROCEDURES: Logistic regression models were performed to analyze the relationship between topical flurbiprofen and development of glaucoma and to predict potential risk factors for postoperative glaucoma occurrence. RESULTS: Eighty-three eyes (65 dogs) were included. The mean age at surgery was 8.2 years, with even gender distribution. Increasing age at the time of surgery significantly increased the probability of postoperative glaucoma occurrence (odds ratio [OR] = 1.344, 95% confidence interval [CI] 1.093-1.652; p = 0.005). Glaucoma occurred in 17/83 (20.5%) eyes; of these, 15/38 (39.5%) and 2/45 (4.4%) eyes were prescribed topical flurbiprofen plus corticosteroids and topical corticosteroids alone, respectively. Immediate postoperative use of topical flurbiprofen was significantly associated with an increased probability of postoperative glaucoma occurrence (OR = 19.183 [95% CI 3.367-109.286], p = 0.001). CONCLUSIONS: Immediate postoperative use of topical flurbiprofen was a potential predisposing risk factor for the development of glaucoma following phacoemulsification. Restriction of postoperative use of topical flurbiprofen might decrease the possibility of postoperative glaucoma development in dogs.


Assuntos
Anti-Inflamatórios não Esteroides/efeitos adversos , Doenças do Cão/etiologia , Flurbiprofeno/efeitos adversos , Glaucoma/veterinária , Facoemulsificação/veterinária , Administração Tópica , Corticosteroides/uso terapêutico , Animais , Anti-Inflamatórios não Esteroides/administração & dosagem , Doenças do Cão/induzido quimicamente , Doenças do Cão/epidemiologia , Cães , Feminino , Flurbiprofeno/administração & dosagem , Seguimentos , Glaucoma/epidemiologia , Glaucoma/etiologia , Incidência , Masculino , Facoemulsificação/efeitos adversos , Cuidados Pós-Operatórios/veterinária , Estudos Retrospectivos , Fatores de Risco
5.
Vet Ophthalmol ; 24 Suppl 1: 186-193, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32501651

RESUMO

OBJECTIVE: To evaluate the clinical relevance of intraocular pressure (IOP) measured with three different rebound tonometers in an ex vivo analysis and clinical trials in dogs. ANIMALS AND PROCEDURES: Ex vivo analysis and clinical trials were performed separately. For the ex vivo analysis, eight enucleated eyes were obtained from four Beagle dogs. IOP values measured with TONOVET® (TV-IOP), TONOVET-Plus® (TVP-IOP), and SW-500® (SW-IOP) were compared with manometric IOPs. For clinical trials, each tonometer was evaluated separately, depending on whether TVP-IOP was higher or lower than 14 mm Hg. One-way repeatedmeasures analysis of variance, simple linear regression analysis, and Bland-Altman plots were used for statistical analyses. RESULTS: In ex vivo analysis, TV-IOP and TVP-IOP were not significantly different from manometric IOP. However, SW-IOP underestimated IOP compared to manometry. Higher discrepancy was observed in TV-IOP and SW-IOP with an increase in manometric IOP. In clinical trials, no significant difference was observed between TV-IOP (9.73 ± 2.92) and TVP-IOP (11.36 ± 2.23) when TVP-IOP was lower than 14 mm Hg, but SW-IOP (8.70 ± 3.03) was significantly lower than TVP-IOP. TV-IOP (15.96 ± 6.47) and SW-IOP (13.09 ± 3.72) were significantly lower than TVP-IOP (20.08 ± 6.60) when the IOP was higher than 14 mm Hg of TVP-IOP. CONCLUSIONS: This study demonstrates that the TONOVET® and TONOVET-Plus® provide a useful approach for ex vivo analysis. In clinical trials, results of TV-IOP and SW-IOP were significantly lower than of TVP-IOP when IOP was higher than 14 mm Hg of TVP-IOP. The characteristics of rebound tonometers should be considered in clinical settings.


Assuntos
Pressão Intraocular , Tonometria Ocular/veterinária , Animais , Cães , Técnicas In Vitro , Tonometria Ocular/instrumentação , Tonometria Ocular/métodos
6.
Molecules ; 25(12)2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-32560497

RESUMO

The aggregation of zinc oxide nanoparticles leads to an increased absorbance in the ultraviolet-visible region by an induced light scattering effect. Herein, we demonstrate the inhibition of photoconversion activity in ZnO-graphene core-shell quantum dots (QD) (ZGQDs) agglomerated by 4-aminophenol (4-AP) used as a linker. The ZnO-graphene quantum dots (QD) aggregates (ZGAs) were synthesized using a facile solvothermal process. The ZGAs revealed an increased absorbance in the wavelengths between 350 and 750 nm as compared with the ZGQDs. Against expectation, the calculated average photoluminescence lifetime of ZGAs was 7.37 ns, which was 4.65 ns longer than that of ZGQDs and was mainly due to the high contribution of a slow (τ2, τ3) component by trapped carriers in the functional groups of graphene shells and 4-AP. The photoelectrochemical (PEC) cells and photodetectors (PDs) were fabricated to investigate the influence of ZGAs on the photoconversion activity. The photocurrent density of PEC cells with ZGAs was obtained as 0.04 mA/cm2 at 0.6 V, which was approximately 3.25 times lower than that of the ZGQDs. The rate constant value of the photodegradation value of rhodamine B was also decreased by around 1.4 times. Furthermore, the photoresponsivity of the PDs with ZGAs (1.54 µA·mW-1) was about 2.5 times as low as that of the PDs with ZGQDs (3.85 µA·mW-1). Consequently, it suggests that the device performances could be degraded by the inhibition phenomenon of the photoconversion activity in the ZGAs due to an increase of trap sites.


Assuntos
Aminofenóis/química , Técnicas Eletroquímicas , Fotólise , Pontos Quânticos/química , Rodaminas/química , Óxido de Zinco/química
7.
J Sports Sci ; 37(4): 364-369, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30073917

RESUMO

Johnston, Benton, and Nishida (2003, Last but not least - Golfers may have to overcome a persistent visuospatial illusion. Perception, 32(9), 1151-1154) reported that when standing sideways to hit a golf ball, it becomes very difficult to see the veridical line of putt to the target and it creates a bias to misread the direction to the right of target. The purpose of the study was to determine if this perceptual aiming bias also impacts putting. A group of expert (N = 24) and novice (N = 24) players performed a perception task of aligning a line on the golf ball towards the target hole and an action task of putting a ball to the target hole located 1 m and 4 m away. Novice players showed large perceptual aiming bias and small action aiming bias of putting. Yet, expert players showed neither bias in perceptual aiming nor in putting. This replicates earlier work (van Lier, van der Kamp, & Savelsbergh, 2011 Perception action in golf putting: Skill differences reflect calibration. Journal of Sport & Exercise Psychology, 33(3), 349-369) and was explained by the two-visual-pathway hypothesis. Despite the results showing some favorable support for the two-visual-pathway hypothesis, possible limitations are discussed.


Assuntos
Desempenho Atlético/psicologia , Golfe/psicologia , Desempenho Psicomotor , Adolescente , Adulto , Viés , Percepção de Distância , Feminino , Humanos , Masculino , Percepção Visual , Adulto Jovem
8.
Perception ; 46(9): 1118-1126, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28467169

RESUMO

While the two visual system hypothesis tells a fairly compelling story about perception and action in peripersonal space (i.e., within arm's reach), its validity for extrapersonal space is very limited and highly controversial. Hence, the present purpose was to assess whether perception and action differences in peripersonal space hold in extrapersonal space and are modulated by the same factors. To this end, the effects of an optic illusion in perception and action in both peripersonal and extrapersonal space were compared in three groups that threw balls toward a target at a distance under different target eccentricity (i.e., with the target fixated and in peripheral field), viewing (i.e., binocular and monocular viewing), and delay conditions (i.e., immediate and delayed action). The illusory bias was smaller in action than in perception in peripersonal space, but this difference was significantly reduced in extrapersonal space, primarily because of a weakening bias in perception. No systematic modulation of target eccentricity, viewing, and delay arose. The findings suggest that the two visual system hypothesis is also valid for extra personal space.


Assuntos
Atividade Motora/fisiologia , Ilusões Ópticas/fisiologia , Espaço Pessoal , Percepção Espacial/fisiologia , Visão Binocular/fisiologia , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
9.
J Phys Ther Sci ; 27(2): 367-70, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25729169

RESUMO

[Purpose] The purpose of this study was to examine the effects of selective exercise for the deep abdominal muscles (SEDA) and lumbar stabilization exercise (LSE) on the thickness of the transversus abdominis and postural maintenance on an unstable base of support. [Subjects and Methods] The subjects of this study were 20 male and 10 female adults in their 20s without lumbar pain. They were equally and randomly assigned to a SEDA group and a LSE group. The thickness of the transversus abdominis was measured using ultrasound imaging during rest and drawing-in. The thickness of the transversus abdominis was measured when subjects raised their right and left legs while lying on a Swiss ball. [Results] Initially, there were no differences between the two groups. After the intervention, significant differences were observed in all parameters. A significant interaction between group and period was not found for any parameters. [Conclusion] In conclusion, both SEDA and LSE thickened the transversus abdominis, which is a deep abdominal muscle, thereby adjusting posture, and stabilizing the trunk. These exercises increased the thickness of the deep abdominal muscles. They are important exercises for improving the stability of athletes or patients who need postural adjustment.

10.
Opt Lett ; 39(8): 2423-6, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24979009

RESUMO

We report a partially directional microdisk semiconductor laser with subwavelength-scale boundary perturbations for asymmetric backscattering of counterpropagating whispering gallery modes. Unlike the previous approaches based on optical bistability, the directionality and chirality of the laser modes can be fine-tuned and partially controlled by adjusting the dimension, shape, and relative positions of Rayleigh scatterers on the microdisk perimeter. The controlled directionality is investigated using numerical simulations and experiments for wavelength-scale microdisk resonators with an azimuthal mode number of 5.

11.
Opt Lett ; 38(10): 1694-6, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23938914

RESUMO

We report room-temperature lasing from an optically pumped subwavelength-scale cylindrical InGaAsP pillar surrounded by circular Bragg reflectors on a metal substrate with a dielectric spacer layer. By taking advantage of wide in-plane photonic bandgaps and proper vertical antiresonances, three dielectric Bragg pairs produce a sufficient optical feedback capable of low threshold lasing from the fundamental TE011 mode. A large spontaneous emission coupling into the lasing mode is obtained from the cavity-enhanced Purcell effects and effective suppression of nonlasing modes.

12.
J Vet Sci ; 24(1): e6, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36560838

RESUMO

Two Shih-Tzu dogs with atopic dermatitis presented with delayed periocular dermatitis (PD) following the instillation of dorzolamide and dorzolamide/timolol combination eyedrops; the development of dermatologic signs took 94 and 104 d in cases 1 and 2, respectively. Hypersensitivity to anti-glaucoma eyedrops was highly suspected, and treatment was discontinued. Delayed PD was significantly relieved in cases 1 and 2, at days 155 and 64 after discontinuation, respectively. In this study, the clinical characteristics and progression of delayed PD were described to inform clinicians who may encounter this rare side effect.


Assuntos
Dermatite Atópica , Dermatite Perioral , Doenças do Cão , Glaucoma , Cães , Animais , Soluções Oftálmicas/uso terapêutico , Dermatite Atópica/tratamento farmacológico , Dermatite Atópica/veterinária , Dermatite Perioral/veterinária , Glaucoma/tratamento farmacológico , Glaucoma/veterinária , Doenças do Cão/induzido quimicamente , Doenças do Cão/tratamento farmacológico
13.
J Vet Sci ; 24(4): e34, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37532293

RESUMO

BACKGROUND: There has not been a thoroughly reported study of the comparison between spectral domain-optical coherence tomography (SD-OCT) with both ultrasound biomicroscopy (UBM) and gonioscopy on the evaluation of the iridocorneal angle (ICA) in dogs. OBJECTIVES: To investigate the diagnostic value of SD-OCT for the early detection of narrowing ICA by comparing and assessing inter-device agreement in anterior chamber angle (ACA) measurements obtained by SD-OCT and UBM, and ICA evaluations by gonioscopy. METHODS: A total of 28 eyes from 28 client-owned dogs with normal intraocular pressure were included for examination. The ACA and angle opening distance (AOD) were measured from the SD-OCT and UBM images, and gonioscopy images were analyzed using the ICA grade and ZibWest angle index. RESULTS: The mean ACA and AOD for SD-OCT were 28.31° ± 5.37° and 658.42 ± 219.90 µm, and for UBM, 28.34° ± 5.82° and 859.29 ± 221.80 µm, respectively. The mean difference in ACA between the average values of SD-OCT and UBM measurements was 0.03° with a 95% limit of agreement (LoA) span of 16.2°, indicating positive agreement; that in AOD was 200.85 µm with a 95% LoA span of 1,110.95 µm, indicating poor agreement. The Pearson correlation coefficient of the ACA of SD-OCT and ZibWest indices of gonioscopy was 0.624, indicating strong agreement; that of UBM and gonioscopy was 0.43, indicating moderate agreement. CONCLUSIONS: SD-OCT is well tolerated by canine patients due to its non-contact method and might be an alternative option for early screening of ICA narrowing in clinical settings.


Assuntos
Microscopia Acústica , Tomografia de Coerência Óptica , Cães , Animais , Gonioscopia , Microscopia Acústica/veterinária , Microscopia Acústica/métodos , Tomografia de Coerência Óptica/veterinária , Olho , Pressão Sanguínea
14.
Gait Posture ; 98: 78-84, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36063571

RESUMO

BACKGROUND: The appearance of a stair can impact the safe negotiation of stair climbing. Increasing toe clearance height is a common strategy for reducing the risk of tripping when stepping onto a raised surface. RESEARCH QUESTION: Can the Müller-Lyer illusion cause people to increase their toe clearance height when walking over a stair? METHODS: Indoors, 15 healthy individuals (9 women and 6 men) walked up a 3-step staircase with each step 60 cm wide, 18 cm tall, and 30.5 cm deep. Outdoors, 253 people walked up a 2-step staircase with each step 6 m wide, 15 cm tall, and 38 cm deep. Four visual conditions were displayed at both the indoor and outdoor locations: fins out, fins in, line, and control. RESULTS: While the fins out stairs were perceived taller than all the other displayed stair conditions, the toe clearance height was not different between display conditions when tested indoors. However, toe clearance height was greater in the fins out condition when compared to all other conditions for the outdoor stairs location. SIGNIFICANCE: In the natural environment when walkers were oblivious to themselves being filmed and not having any knowledge of the task demand, the Müller-Lyer illusion significantly impacted their toe clearance height.


Assuntos
Marcha , Ilusões , Masculino , Humanos , Feminino , Caminhada , Cinética , Dedos do Pé
15.
J Vet Sci ; 23(1): e10, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34841748

RESUMO

BACKGROUND: Dry eye disease (DED) cannot be diagnosed by a single test because it is a multifactorial disorder of the ocular surface. Although studies on various dry eye tests (DETs) in dogs have been reported, standard criteria have not been established except for the Schirmer tear test 1 (STT-1). OBJECTIVES: To establish reference values for DETs in dogs with normal STT-1 values (≥ 15 mm/min) and to analyze the correlation between DETs. METHODS: The STT-1 was performed in 10 healthy Beagle dogs (20 eyes). After 20 min, interferometry (IF) for estimating the lipid layer thickness (LLT) of the tear film, tear meniscus height (TMH), non-invasive tear breakup time (NIBUT), and meibomian gland loss rate of the upper eyelid (MGLRU) and lower eyelid (MGLRL), were measured using an ocular surface analyzer. RESULTS: Mean values for STT-1, TMH, and NIBUT were as follows: 21.7 ± 3.4 mm/min, 0.41 ± 0.21 mm, and 19.1 ± 9.5 sec, respectively. The most frequent LLT range, measured by IF, was 30-80 nm (11 eyes), followed by 80 nm (5 eyes) and 80-140 nm (4 eyes). MGLRU ≤ 25% was measured in 11 eyes and 26%-50% in 9 eyes; MGLRL ≤ 25% in 8 eyes and 26%-50% in 12 eyes. Besides positive correlation between TMH and NIBUT (P = 0.038), there were no significant associations between DETs. CONCLUSIONS: Data obtained in this study provided normative references that could be useful for diagnosing DED and for further research into correlation between DETs in dogs with DED.


Assuntos
Doenças do Cão , Síndromes do Olho Seco , Animais , Doenças do Cão/diagnóstico , Cães , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/veterinária , Lipídeos , Glândulas Tarsais , Projetos Piloto , Valores de Referência , Lágrimas
16.
Vet Med Sci ; 8(4): 1816-1824, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35305285

RESUMO

BACKGROUND: No previous studies have quantified tear glucose (TG) levels in dogs or compared changes in TG and blood glucose (BG) concentrations. OBJECTIVE: To quantify TG concentration and evaluate its correlation with BG level in dogs. METHODS: Twenty repetitive tests were performed in alternate eyes of four dogs, with a minimum washout period of 1 week. Tears and blood were collected at 30-min intervals with successive glucose injections (1 g/kg) every 30 min. Cross-correlations of BG and TG levels were assessed. The delay and association between TG and corresponding BG levels were analysed for each dog; samples were collected at 5-min intervals. The tears were collected using microcapillary tubes. Collected tears and blood were analysed for glucose concentration using a colorimetric assay and commercially available glucometer, respectively. RESULTS: The average baseline BG and TG levels were 4.76 ± 0.58 and 0.39 ± 0.04 mmol/L, respectively. Even with highly fluctuating BG levels, a significant cross-correlation coefficient (r = 0.86, p < 0.05) was observed between changes of BG and TG levels. The delay time between BG and TG levels was 10 min. On average, BG levels were 16.34 times higher than TG levels. There was strong correlation between BG and TG levels (rs  = 0.80, p < 0.01). Significant differences in TG concentrations between normoglycaemia, mild hyperglycaemia, and severe hyperglycaemia were found (p < 0.05). CONCLUSIONS: Canine TG concentrations have not been quantified previously. Our findings suggest preliminary data for future research on TG levels in dogs and show TG measurement could be used to screen for diabetes mellitus in dogs.


Assuntos
Diabetes Mellitus , Doenças do Cão , Hiperglicemia , Animais , Glicemia/análise , Diabetes Mellitus/veterinária , Cães , Glucose , Hiperglicemia/veterinária , Lágrimas
17.
Vet Rec ; 191(2): e1682, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35486802

RESUMO

BACKGROUND: Interest in meibomian gland dysfunction (MGD) is growing in veterinary medicine. However, research on MGD in dogs is lacking. The aims of this study were to compare the interferometry grades, tear meniscus height (TMH) and non-invasive tear break-up time (NIBUT) grades between dogs with and without MGD. METHODS: Routine ophthalmic examination, interferometry, NIBUT assessment, TMH measurement and meibography were performed. Age and Schirmer tear test-1 (STT-1) results were compared between the control and MGD groups using Student's t-test. Interferometry grades, NIBUT grades and TMH were compared between the two groups using Mann-Whitney U-test. RESULTS: There was no significant difference in age between the two groups (p = 0.279). STT-1 (p = 0.024), interferometry (p = 0.004) and NIBUT grades (p = 0.012) were significantly lower in the MGD group than in the control group. No significant difference in TMH values (p = 0.587) was observed between the two groups. While the control group included 18 and seven eyes in meiboscore 0 and 1, in MGD group, 12, eight, five and three eyes were included in meiboscore 0, 1, 2 and 3, respectively. CONCLUSIONS: Low interferometry and NIBUT grades were associated with MGD, suggesting decreased meibum and disrupted tear film quality. TMH did not differ between the two groups. Meibography could aid in the diagnosis of MGD in severe cases, although it could not detect early MGD in the dogs in this study.


Assuntos
Doenças do Cão , Síndromes do Olho Seco , Disfunção da Glândula Tarsal , Animais , Doenças do Cão/diagnóstico , Cães , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/veterinária , Humanos , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/veterinária , Glândulas Tarsais , Lágrimas
18.
J Nanosci Nanotechnol ; 21(8): 4444-4449, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33714342

RESUMO

Epoxy adhesive was analyzed under long term thermal aging and mechanical properties and chemical degradation were observed by X-ray photoelectron spectroscopy (XPS). Long term thermal exposure of epoxy causes a noticeable reduction in adhesive properties. We developed a predictive model of temperature and time dependent aging. The temperature dependent aging behavior of epoxy adhesive shows good agreement with conventional Arrhenius equations. Using XPS analysis, we also discovered a correlation between chemical degradation and the adhesive properties. Decay of C-C bonding ratio induced chain-scission of epoxy adhesive; increase of total numbers of C-O and C═O induced oxidation of epoxy adhesive during thermal exposure.

19.
Sci Rep ; 9(1): 9866, 2019 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-31285525

RESUMO

Achieving perfect light absorption at a subwavelength-scale thickness has various advantageous in terms of cost, flexibility, weight, and performance for many different applications. However, obtaining perfect absorbers covering a wide range of wavelengths regardless of incident angle and input polarization without a complicated patterning process while maintaining a small thickness remains a challenge. In this paper, we demonstrate flat, lithography-free, ultrahigh omnidirectional, polarization-independent, broadband absorbers through effective dispersion engineering. The proposed absorbers show day-integrated solar energy absorption up to 96%, which is 32% better than with lossy semiconductor/metal absorbers. The proposed simple yet effective method can be applied to light absorption thin film structures based on various types of highly lossy semiconductor materials, including emerging 2D materials.

20.
J Vet Sci ; 20(5): e47, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31565890

RESUMO

The purpose of this study was to develop effective dental hygiene chews for cats based on the anatomical features of the dentition and patterns of chewing motion. All cats were volunteered for dental prophylaxis followed by dental impressions using yellow stone and alginate under general anesthesia. Twenty parameters related to dentition were defined in order to compare dental impressions using digital caliper. For the chewing motion study, patterns of chewing motion were identified based on recordings made with a digital camera. Ten cats (4 domestic shorthairs, 2 Russian blues, 1 American shorthair, 1 Persian, 1 Turkish Angora, and 1 Devon Rex) were recruited for the study. The parameters related to teeth and oral size were similar among the studied cats. Chewing motion can be described as more of a guillotine-like motion rather than a crushing motion, with cats chewing 3-7 times before swallowing. The chewing pattern of cats involves shearing for a short period of time followed by immediate swallowing. Therefore, the overall size of the dental hygiene chew could be determined based on the measurement of the oral size for inducing chewing. The surface details of the dental hygiene chew could be designed for prevention and removal of dental calculus and plaque in cats considering the anatomical teeth parameters. Dental hygiene chews customized for cats considering the different anatomical features of their teeth might be effective for oral care.


Assuntos
Goma de Mascar/análise , Placa Dentária/veterinária , Higiene Bucal/veterinária , Animais , Gatos , Placa Dentária/tratamento farmacológico , Dentição , Higiene Bucal/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA