Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Nanomedicine ; 41: 102531, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35114406

RESUMO

Neuromyelitis optica spectrum disorder (NMOSD) is an inflammatory and autoimmune disease whose biomarker is the anti-AQP4-IgG autoantibody that binds to aquaporin-4 (AQP4) protein. We introduced a nanosensor with a sensitivity of 84.6%, higher than the CBA's 76.5%. Using silver nanoparticles (AgNPs), we detected not only seropositive but also some false-negative patients previously classified with CBA. It consisted of AgNPs coated with one of a panel of 5 AQP4 epitopes. The ability in detecting the anti-AQP4-IgG in NMOSD patients depended on the epitope and synergy could be obtained by combining different epitopes. We demonstrated that NMOSD patients could easily be distinguished from healthy subjects and patients with multiple sclerosis. Using the most sensitive AQP461-70 peptide, we established a calibration curve to estimate the concentration of anti-AQP4-IgG in seropositive NMOSD patients. The ability to enhance the accuracy of the diagnosis may improve the prognosis of 10-27% of anti-AQP4-IgG seronegative patients worldwide.


Assuntos
Nanopartículas Metálicas , Neuromielite Óptica , Aquaporina 4 , Colorimetria , Humanos , Imunoglobulina G , Neuromielite Óptica/diagnóstico , Prata
2.
AAPS PharmSciTech ; 23(2): 69, 2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35112208

RESUMO

In this study, chloroquine resinates were prepared at a 1:1 (w:w) drug-to-resin ratio using the batch method with polacrilex (PC), sodium polystyrene sulfonate (SPS), and polacrilin potassium (PP) ion exchange resins (IER). The influence of drug/resin ratio and pH of the medium on drug loading efficiency was explored. UV-VIS spectrophotometric analysis showed that SPS resin had high loading efficiency for chloroquine diphosphate (CLP), above 89%, regardless of the pH. PP resin was more effective at pH 5.0 (90.68%) than at pH 1.0 (2.09%), and PC resin had only 27.63% of CLP loading efficiency. CLP complexation with IER yielded amorphous mixtures according to results from differential scanning calorimetry (DSC) and X-ray powder diffraction (XRPD), thus indicating drug-resin interaction. The taste masking efficiency was evaluated with in vitro methods using an adapted dissolution test and an electronic tongue system. During dissolution tests, SPS released only 1.0% of CLP after 300 s, while PP released over 10% after 90 s in simulated saliva solution. The electronic tongue distinguished the samples containing CLP, resins, and resinates by using multidimensional projection techniques that indicated an effective drug taste masking. In an accelerated stability study, the drug contents did not decrease in chloroquine resinates, and there was no physical degradation of the resinates after 60 days. Using chloroquine resinates therefore represents a novel way to evaluate taste masking in vitro which is relevant for the early formulation development process.


Assuntos
Resinas de Troca Iônica , Paladar , Administração Oral , Criança , Cloroquina , Estudos de Viabilidade , Humanos
3.
AAPS PharmSciTech ; 23(1): 22, 2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-34907488

RESUMO

The assessment of drug taste is crucial for pediatric treatments so that formulations can be developed to enhance their effectiveness. In this study, in vivo and in vitro methods were applied to evaluate the taste of tablets of three drugs administered to children without taste-masking excipients to treat tropical diseases, namely artesunate-mefloquine (ASMQ), praziquantel (PZQ), and benznidazole (BNZ). In the first method, a model of rat palatability was adapted with recirculation to ensure sample dispersion, and the data were analyzed using ANOVA (single factor, 95%). The taste assessment results (in vivo) indicated an aversion to the three medicines, denoted by the animals retracting themselves to the bottom of the box after the first contact with the drugs. For the placebo samples, the animals behaved normally, indicating that taste perception was acceptable. The second method was based on the in vitro analysis of capacitance data from a homemade impedimetric electronic tongue. Consistent with the in vivo taste assessment results, the data points obtained with PZQ, ASMQ, and BNZ were far away from those of their placebos in a map built with the multidimensional projection technique referred to as Interactive Document Mapping (IDMAP). A combined analysis of the results with the two methods allowed us to confirm the bitterness of the three drugs, also pointing to electronic tongues as a promising tool to replace in vivo palatability tests.


Assuntos
Mefloquina , Praziquantel , Animais , Artesunato , Criança , Humanos , Nitroimidazóis , Ratos , Comprimidos , Paladar
4.
Sensors (Basel) ; 20(21)2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-33143197

RESUMO

Incorporating electronic tongues into microfluidic devices brings benefits as dealing with small amounts of sample/discharge. Nonetheless, such measurements may be time-consuming in some applications once they require several operational steps. Here, we designed four collinear electrodes on a single printed circuit board, further comprised inside a straight microchannel, culminating in a robust e-tongue device for faster data acquisition. An analog multiplexing circuit automated the signal's routing from each of the four sensing units to an impedance analyzer. Both instruments and a syringe pump are controlled by dedicated software. The automated e-tongue was tested with four Brazilian brands of liquid sucralose-based sweeteners under 20 different flow rates, aiming to systematically evaluate the influence of the flow rate in the discrimination among sweet tastes sold as the same food product. All four brands were successfully distinguished using principal component analysis of the raw data, and despite the nearly identical sucralose-based taste in all samples, all brands' significant distinction is attributed to small differences in the ingredients and manufacturing processes to deliver the final food product. The increasing flow rate improves the analyte's discrimination, as the silhouette coefficient reaches a plateau at ~3 mL/h. We used an equivalent circuit model to evaluate the raw data, finding a decrease in the double-layer capacitance proportional to improvements in the samples' discrimination. In other words, the flow rate increase mitigates the formation of the double-layer, resulting in faster stabilization and better repeatability in the sensor response.

5.
Mikrochim Acta ; 186(7): 418, 2019 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-31187269

RESUMO

Two kinds of flexible ozone (O3) sensors were obtained by placing pristine ZnO nanorods and gold-modified ZnO nanorods (NRs) on a bi-axially oriented poly(ethylene terephthalate) substrate. The chemiresistive sensor is operated at typically 1 V at room temperature under the UV-light illumination. The ZnO nanorods were prepared via a hydrothermal route and have a highly crystalline wurtzite structure, with diameters ranging between 70 and 300 nm and a length varying from 1 to 3 µm. The ZnO NRs were then coated with a ca. 10 nm gold layer whose presence was confirmed with microscopy analysis. This sensor is found to be superior to detect ozone at a room temperature. Typical figures of merit include (a) a sensor response of 108 at 30 ppb ozone for gold-modified ZnO NRs, and (b) a linear range that extends from 30 to 570 ppb. The sensor is stable, reproducible and selective for O3 compared to other oxidizing and reducing gases. The enhanced performance induced by the modification of ZnO nanorods with thin layer of gold is attributed to the increased reaction kinetics compared to pristine ZnO NRs. The sensing mechanism is assumed to be based on the formation of a nano-Schottky type barrier junction at the interface between gold and ZnO. Graphical abstract Room temperature, flexible UV-enhanced gold modified ZnO nanorods can detect ppb levels of ozone.

6.
Sensors (Basel) ; 19(23)2019 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-31766686

RESUMO

"Electronic tongues", "taste sensors", and similar devices (further named as "multisensor systems", or MSS) have been studied and applied mostly for the analysis of edible analytes. This is not surprising, since the MSS development was sometimes inspired by the mainstream idea that they could substitute human gustatory tests. However, the basic principle behind multisensor systems-a combination of an array of cross-sensitive chemical sensors for liquid analysis and a machine learning engine for multivariate data processing-does not imply any limitations on the application of such systems for the analysis of inedible media. This review deals with the numerous MSS applications for the analysis of inedible analytes, among other things, for agricultural and medical purposes.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletrônica/instrumentação , Nariz Eletrônico , Desenho de Equipamento/instrumentação , Humanos , Paladar/fisiologia , Língua/fisiologia
7.
Anal Chem ; 90(21): 12377-12384, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30222327

RESUMO

This technical note describes a new microfluidic sensor that combines low-cost (USD $0.97) with rapid fabrication and user-friendly, fast, sensitive, and accurate quantification of a breast cancer biomarker. The electrodes consisted of cost-effective bare stainless-steel capillaries, whose mass production is already well-established. These capillaries were used as received, without any surface modification. Microfluidic chips containing electrical double-layer capillary capacitors (µEDLC) were obtained by a cleanroom-free prototyping that allows the fabrication of dozens to hundreds of chips in 1 h. This sensor provided the successful quantification of CA 15-3, a biomarker protein for breast cancer, in serum samples from cancer patients. Antibody-anchored magnetic beads were utilized for immunocapture of the marker, and then, water was added to dilute the protein. Next, the CA 15-3 detection (<2 min) was made without using redox probes, antibody on electrode (sandwich immunoassay), or signal amplification strategies. In addition, the capacitance tests eliminated external pumping systems and precise volumetric sampling steps, as well as presented low sample volume (5 µL) and high sensitivity using bare capillaries in a new design for double-layer capacitors. The achieved limit-of-detection (92.0 µU mL-1) is lower than that of most methods reported in the literature for CA 15-3, which are based on nanostructured electrodes. The data shown in this technical note support the potential of the µEDLC toward breast cancer diagnosis even at early stages. We believe that accurate analyses using a simple sample pretreatment such as magnetic field-assisted immunocapture and cost-effective bare electrodes can be extended to quantify other cancer biomarkers and even biomolecules by changing the biorecognition element.


Assuntos
Biomarcadores Tumorais/análise , Técnicas Biossensoriais/economia , Neoplasias da Mama/diagnóstico por imagem , Técnicas Eletroquímicas/economia , Técnicas Analíticas Microfluídicas/economia , Mucina-1/análise , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Eletrodos , Feminino , Humanos , Técnicas Analíticas Microfluídicas/instrumentação
8.
Anal Biochem ; 553: 46-53, 2018 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-29802842

RESUMO

Disperse Orange 37 (DO37) is an efficient azo dye for dyeing synthetic textile materials owing to its resistance to degradation that may also be harmful to humans as DO37 is not entirely eliminated in wastewater treatment. In this paper, we demonstrate that DO37 is bleached by reduced glutathione (GSH) in a reaction catalyzed by glutathione-s-transferase (GST), a phase II detoxification enzyme. The reaction included a nucleophilic attack involving sulfhydryl groups, confirmed using density functional theory (DFT) calculations. DO37 also induced quenching in the fluorescence of GST through static suppression. The reaction was determined using differential pulse voltammetry (DPV) by monitoring the oxidation peak at 0.65 V of GSH sulfhydryl group. Quantitative estimation of the product reaction could be made by measuring an additional oxidation peak at 0.91 V which increased linearly with DO37 concentration. These electrochemical determinations were made possible by preconcentrating the reaction product on a graphite-epoxy electrode with immobilization of GST onto magnetite nanoparticles. Straightforward biological implications from the results are associated with the known toxicity of azo dyes such as DO37, which has been proven here to interact strongly with both GSH and the liver enzyme GST, and may induce hepatocarcinogenesis or other types of cancer.


Assuntos
Compostos Azo/química , Técnicas Eletroquímicas/métodos , Glutationa Transferase/metabolismo , Fígado/metabolismo , Proteínas/metabolismo , Catálise , Teoria da Densidade Funcional , Humanos , Fígado/enzimologia , Nanopartículas de Magnetita/química , Oxirredução
9.
Nanotechnology ; 29(50): 505703, 2018 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-30215613

RESUMO

The unique electronic, mechanical and optical properties of graphene make it a remarkable 2D material, widely explored in a plethora of applications. However, graphene zero-bandgap and the production of defect-free pristine graphene in large areas still limit some applications. To circumvent these issues, graphene-derived 2D materials have arisen as attractive candidates for low-dimensional systems, which requires a better comprehension of their properties. Here, we report a detailed investigation of the conduction mechanisms of two functionalized reduced graphene oxides (rGOs) nanoplatelets, named GPAH and GPSS. The functionalized rGO nanoplatelets were bottom-up assembled via the layer-by-layer technique, enabling molecular-level thickness control of nanostructures with well-defined composition and structure. For the reported multilayered GPAH/GPSS films the charge carriers followed Mott's law, presenting a typical conduction behavior of 2D systems described by the Poole-Frenkel model. The multilayered GPAH/GPSS nanostructure presented a conductivity of 10-4 S cm-1, optical bandgap of ∼3.3 eV and a relative dielectric permittivity (ε r) of 6.4. Temperature-dependent I-V measurements indicated a strong variation of ε r below the critical temperature (T C = 237 K), associated with a high dipole reorientation in the formed GPAH/GPSS nanostructure. All these characteristics make the GPAH/GPSS nanocomposite attractive for graphene-oriented applications, such as electronic devices.

11.
Phys Chem Chem Phys ; 16(44): 24275-81, 2014 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-25298297

RESUMO

The fabrication of nanostructured films with tailored properties is essential for many applications, particularly with materials such as polyaniline (PANI) whose electrical characteristics may be easily tuned. In this study we report the one-step synthesis of AgCl-PANI nanocomposites that could form layer-by-layer (LbL) films with poly(sodium 4-styrenesulfonate) (PSS) and be used for electronic tongues (e-tongues). The first AgCl-PANI layer was adsorbed on a quartz substrate according to a nucleation-and-growth mechanism explained using the Johnson-Mehl-Avrami (JMA) model, revealing a 3D film growth confirmed by atomic force microscopy (AFM) measurements for the AgCl-PANI/PSS LbL films. In contrast to conventional PANI-containing films, the AgCl-PANI/PSS LbL films deposited on interdigitated electrodes exhibited electrical resistance that was practically unaffected by changes in pH from 4 to 9, and therefore these films can be used in e-tongues for both acidic and basic media. With a sensor array made of AgCl-PANI/PSS LbL films with different numbers of bilayers, we demonstrated the suitability of the AgCl-PANI nanocomposite for an e-tongue capable of clearly discriminating the basic tastes from salt, acid and umami solutions. Significantly, the hybrid AgCl-PANI nanocomposite is promising for any application in which PANI de-doping at high pH is to be avoided.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38537173

RESUMO

Nanostructured microelectrodes (NMEs) are an attractive alternative to yield sensitive bioassays in unprocessed samples. However, although valuable for different applications, nanoporous NMEs usually cannot boost the sensitivity of diffusion-limited analyses because of the enlarged Debye length within the nanopores, which reduces their accessibility. To circumvent this limitation, nanopore-free gold NMEs were electrodeposited from 45 µm SU-8 apertures, featuring nanoridged microspikes on a recessed surface of gold thin film while carrying interconnected crown-like and spiky structures along the edge of a SU-8 passivation layer. These structures were grown onto ultradense, vertical array chips that offer a promising strategy for translating reproducible, high-resolution, and cost-effective sensors into real-world applications. The NMEs yielded reproducible analyses, while machine learning allowed us to predict the analytical responses from NME electrodeposition data. By taking advantage of the high surface area and accessible structure of the NMEs, these structures provided a sensitivity for [Fe(CN)6]3-/4- that was 5.5× higher than that of bare WEs while also delivering a moderate antibiofouling property in undiluted human plasma. As a proof of concept, these electrodes were applied toward the fast (22 min) and simple determination of Staphylococcus aureus by monitoring the oxidation of [Fe(CN)6]4-, which acted as a cellular respiration rate redox reporter. The sensors also showed a wide dynamic range, spanning 5 orders of magnitude, and a calculated limit of detection of 0.2 CFU mL-1.

13.
Adv Healthc Mater ; 13(11): e2303509, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38245830

RESUMO

Multiplexing is a valuable strategy to boost throughput and improve clinical accuracy. Exploiting the vertical, meshed design of reproducible and low-cost ultra-dense electrochemical chips, the unprecedented single-response multiplexing of typical label-free biosensors is reported. Using a cheap, handheld one-channel workstation and a single redox probe, that is, ferro/ferricyanide, the recognition events taking place on two spatially resolved locations of the same working electrode can be tracked along a single voltammetry scan by collecting the electrochemical signatures of the probe in relation to different quasi-reference electrodes, Au (0 V) and Ag/AgCl ink (+0.2 V). This spatial isolation prevents crosstalk between the redox tags and interferences over functionalization and binding steps, representing an advantage over the existing non-spatially resolved single-response multiplex strategies. As proof of concept, peptide-tethered immunosensors are demonstrated to provide the duplex detection of COVID-19 antibodies, thereby doubling the throughput while achieving 100% accuracy in serum samples. The approach is envisioned to enable broad applications in high-throughput and multi-analyte platforms, as it can be tailored to other biosensing devices and formats.


Assuntos
Técnicas Biossensoriais , COVID-19 , Técnicas Eletroquímicas , SARS-CoV-2 , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Humanos , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/sangue , Eletrodos , Anticorpos Antivirais/sangue , Ouro/química , Imunoensaio/métodos , Imunoensaio/instrumentação
14.
Biomed Pharmacother ; 145: 112426, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34861633

RESUMO

Glutathione-s-transferase is believed to be involved in the resistance to chemotherapeutic drugs, which depends on the interaction with the cell membranes. In this study, we employed Langmuir monolayers of a mixture of phospholipids and cholesterol (MIX) as models for tumor cell membranes and investigated their interaction with the anticancer drugs cisplatin (CDDP) and doxorubicin (DOX). We found that both DOX and CDDP expand and affect the elasticity of MIX monolayers, but these effects are hindered when glutathione-s-transferase (GST) and its cofactor glutathione (GSH) are incorporated. Changes are induced by DOX or CDDP on the polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS) data for MIX/GST/GSH monolayers, thus denoting some degree of interaction that is not sufficient to alter the monolayer mechanical properties. Overall, the results presented here give support to the hypothesis of the inactivation of DOX and CDDP by GST and point to possible directions to detect and fight drug resistance.


Assuntos
Antineoplásicos/farmacologia , Cisplatino/farmacologia , Doxorrubicina/farmacologia , Glutationa Transferase/metabolismo , Membrana Celular/metabolismo , Colesterol/metabolismo , Resistencia a Medicamentos Antineoplásicos/fisiologia , Modelos Biológicos , Fosfolipídeos/metabolismo
15.
Talanta ; 243: 123327, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35240367

RESUMO

The diagnosis of cancer and other diseases using data from non-specific sensors - such as the electronic tongues (e-tongues) - is challenging owing to the lack of selectivity, in addition to the variability of biological samples. In this study, we demonstrate that impedance data obtained with an e-tongue in saliva samples can be used to diagnose cancer in the mouth. Data taken with a single-response microfluidic e-tongue applied to the saliva of 27 individuals were treated with multidimensional projection techniques and non-supervised and supervised machine learning algorithms. The distinction between healthy individuals and patients with cancer on the floor of mouth or oral cavity could only be made with supervised learning. Accuracy above 80% was obtained for the binary classification (YES or NO for cancer) using a Support Vector Machine (SVM) with radial basis function kernel and Random Forest. In the classification considering the type of cancer, the accuracy dropped to ca. 70%. The accuracy tended to increase when clinical information such as alcohol consumption was used in conjunction with the e-tongue data. With the random forest algorithm, the rules to explain the diagnosis could be identified using the concept of Multidimensional Calibration Space. Since the training of the machine learning algorithms is believed to be more efficient when the data of a larger number of patients are employed, the approach presented here is promising for computer-assisted diagnosis.


Assuntos
Neoplasias Bucais , Saliva , Algoritmos , Nariz Eletrônico , Humanos , Aprendizado de Máquina , Neoplasias Bucais/diagnóstico , Máquina de Vetores de Suporte
16.
ACS Appl Mater Interfaces ; 14(49): 54527-54538, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36454041

RESUMO

Low-cost, instrument-free colorimetric tests were developed to detect SARS-CoV-2 using plasmonic biosensors with Au nanoparticles functionalized with polyclonal antibodies (f-AuNPs). Intense color changes were noted with the naked eye owing to plasmon coupling when f-AuNPs form clusters on the virus, with high sensitivity and a detection limit of 0.28 PFU mL-1 (PFU stands for plaque-forming units) in human saliva. Plasmon coupling was corroborated with computer simulations using the finite-difference time-domain (FDTD) method. The strategies based on preparing plasmonic biosensors with f-AuNPs are robust to permit SARS-CoV-2 detection via dynamic light scattering and UV-vis spectroscopy without interference from other viruses, such as influenza and dengue viruses. The diagnosis was made with a smartphone app after processing the images collected from the smartphone camera, measuring the concentration of SARS-CoV-2. Both image processing and machine learning algorithms were found to provide COVID-19 diagnosis with 100% accuracy for saliva samples. In subsidiary experiments, we observed that the biosensor could be used to detect the virus in river waters without pretreatment. With fast responses and requiring small sample amounts (only 20 µL), these colorimetric tests can be deployed in any location within the point-of-care diagnosis paradigm for epidemiological control.


Assuntos
Técnicas Biossensoriais , COVID-19 , Nanopartículas Metálicas , Humanos , Colorimetria/métodos , Ouro/química , SARS-CoV-2 , Nanopartículas Metálicas/química , Ressonância de Plasmônio de Superfície/métodos , Smartphone , Teste para COVID-19 , COVID-19/diagnóstico , Técnicas Biossensoriais/métodos
17.
Colloids Surf B Biointerfaces ; 205: 111889, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34098365

RESUMO

The composition of Langmuir monolayers used as cell membrane models is an essential factor for the interaction with biologically-relevant molecules, including pharmaceutical drugs. In this paper, we report the modulation of effects from the antineoplastic drug paclitaxel by the relative concentration of cholesterol in the Langmuir monolayers of ternary mixtures of dipalmitoylphosphatidylcholine, sphingomyelin, and cholesterol. Since the dependence on cholesterol concentration for these monolayers simulating lipid rafts is non-monotonic, we analyzed the surface pressure and compressibility modulus data with the multidimensional projection technique referred to as interactive document mapping (IDMAP). The maximum expansion induced by paclitaxel in surface pressure isotherms was observed for 27% cholesterol, while the compressibility modulus decreased most strongly for the monolayer with 48% cholesterol. Therefore, the physiological action of paclitaxel may vary depending on whether it is associated with penetration in the membrane or with changes in the membrane elasticity.


Assuntos
1,2-Dipalmitoilfosfatidilcolina , Paclitaxel , Membrana Celular , Colesterol , Membranas Artificiais , Esfingomielinas
18.
ACS Sens ; 6(8): 3125-3132, 2021 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-34399053

RESUMO

The sensing field has shed light on an urgent necessity for field-deployable, user-friendly, sensitive, and scalable platforms that are able to translate solutions into the real world. Here, we attempt to meet these requests by addressing a simple, low-cost, and fast electrochemical approach to provide sensitive assays that consist of dropping a small volume (0.5 µL) of off-the-shelf alcohols on pyrolyzed paper-based electrodes before adding the sample (150 µL). This method was applied in the detection of phosphate after the formation of the phosphomolybdate complex (250-860 nm in size). Prior drops of isopropanol allow for the fast penetration of the sample through pores of this hydrophobic paper, delivering hindrance-free redox reactions across increasing active areas and ultimately improving the detection performance. The sensitivity (-1.9 10-6 mA cm-2 ppb-1) and limit of detection (1.1 ppb) were improved, respectively, by factors of 33 and 99 over the data achieved without the addition of isopropanol, listing among the lowest values when compared with those results reported in the literature for phosphate (expressed in terms of the concentration of phosphorus). The approach enabled the quantification of this analyte in real samples with accuracies ranging from 87 to 103%. Furthermore, preliminary measurements demonstrated the successful performance of the electrodes with prior addition of other widely used alcohols, that is, methanol and ethanol. These results may extend the applicability of the method. In special, the scalability and eco-friendly character of the electrode fabrication combined with the sensitivity and simplicity of the analyses make the developed platform a promising alternative that may help to pave the way for a new generation of disposable sensors toward the daily monitoring of phosphate in water samples, thus contributing to prevent ecological side effects.


Assuntos
Técnicas Eletroquímicas , Fosfatos , Ação Capilar , Eletrodos , Etanol , Porosidade
19.
Colloids Surf B Biointerfaces ; 196: 111357, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32992284

RESUMO

The fight against drug resistance in chemotherapy requires a molecular-level understanding of the drug interaction with cell membranes, which today is feasible with membrane models. In this study, we report on the interaction of gemcitabine (GEM), a pyrimidine nucleoside antimetabolite used to treat pancreatic cancer, with Langmuir films that mimic healthy and cancerous cell membranes. The cell membrane models were made with eight compositions of a quaternary mixture containing 1,2-dipalmitoyl-sn-glycerol-3-phosphocholine (DPPC), 1,2-dipalmitoyl-sn-glycero-3-phosphoserine (DPPS), sphingomyelin (SM), and cholesterol (CHOL). The relative concentration of SM was increased so that four of these compositions represented cancerous cells. GEM was found to increase the mean molecular area, also increasing their surface elasticity, with stronger interactions being observed for membranes corresponding to cancerous cells. More specifically, GEM penetrated deepest in the membrane with the highest SM concentration (40 mol%), as inferred from polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS). This finding was confirmed with molecular dynamics simulations that also indicated how GEM approaches the membrane, which could be useful for guiding the design of drug delivery systems. The experimental and simulation results are consistent with the preferential attachment of GEM onto cancerous cells and highlight the role of SM on drug-cell interactions.


Assuntos
Antineoplásicos , Esfingomielinas , Membrana Celular , Desoxicitidina/análogos & derivados , Glicerol/análogos & derivados , Fosforilcolina/análogos & derivados , Gencitabina
20.
ACS Sens ; 5(6): 1814-1821, 2020 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-32515185

RESUMO

This work describes the development of an electronic nose (e-nose) based on carbon nanocomposites to detect clove essential oil (CEO), eugenol (EUG), and eugenyl acetate (EUG.ACET). Our e-nose system comprises an array of six sensing units modified with nanocomposites of poly(aniline), graphene oxide, and multiwalled carbon nanotubes doped with different acids, dodecyl benzene sulfonic acid, camphorsulfonic acid, and hydrochloric acid. The e-nose presented an excellent analytical performance to the detected analytes (CEO, EUG, and EUG.ACET) with high sensitivity and reversibility. The limit of detection was lower than 1.045 ppb, with response time (<13.26 s) and recovery time (<106.29 s) and low hysteresis. Information visualization methods (PCA and IDMAP) demonstrated that the e-nose was efficient to discriminate the different concentrations of analyte volatile oil compounds. PM-IRRAS measurements suggest that the doping mechanism of molecular architectures is composed of a change in the oscillation energy of the characteristic dipoles and changes in the molecular orientation dipoles C═C and C═O at 1615 and 1740 cm-1, respectively. The experimental results indicate that our e-nose system is promising for a rapid analysis method to monitor the quality of essential oils.


Assuntos
Nanocompostos , Nanotubos de Carbono , Óleos Voláteis , Syzygium , Óleo de Cravo , Nariz Eletrônico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA