Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Fish Shellfish Immunol ; 142: 109159, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37832746

RESUMO

Miamiensis avidus is a parasitic pathogen that causes scuticociliatosis, a severe and often lethal marine infection that affects marine fishes worldwide, including olive flounder (Paralichthys olivaceus) in Korea. This parasite infects all size groups of flounder year-round, causing recurring mortalities and huge economic losses to the Korean flounder industry each year. However, few efforts have been made to implement effective remedial measures to control this parasite. Therefore, our study sought to develop a chitosan microsphere (MS)-encapsulated inactivated vaccine (IMa + chitosan) for oral delivery (adsorbed in feed) to flounder fingerlings and assess its protective efficacy at different modalities via three in vivo experimental trials. Immunisation trial-1 was conducted to determine the effective concentration of chitosan. Our findings indicated that an IMa + chitosan 0.05 % vaccine formulation was safe and effective in providing moderate protection [46.67%-53.3 % relative percent survival (RPS)] against M. avidus intraperitoneal (IP) injection challenge at two weeks post-vaccination (wpv) compared to the IMa + chitosan 0.01 % and IMa + chitosan 0.005 % vaccines (0%-13.3 % RPS) irrespective of the antigen doses. In trial-2, the IMa + chitosan 0.05 % vaccine elicited similar protective immunity (30.8%-57.1 % RPS) in olive flounder against M. avidus at varying antigen doses (high: 2.38 × 106 cells/fish; low: 1.5 × 105 cells/fish), immunisation periods (2 and 5 wpv), and challenge modes (IP injection and immersion). Furthermore, experimental trial-3 validated the use of chitosan MS as an IMa antigen carrier to improve survivability (41.7 % RPS) in the host by significantly (p < 0.05) upregulating specific anti-M. avidus antibody titres in the fish sera and mucus of the group immunised with IMa-containing chitosan MS. In contrast, non-specific immunomodulatory effects (16.7 % RPS and enhanced mucosal antibody titres) were observed in the group treated with chitosan MS without IMa. Therefore, our findings suggested that oral administration of chitosan MS (0.05 %)-encapsulated IMa vaccine is a promising immunisation strategy against M. avidus that can protect the IMa antigen from digestive degradation, facilitates its targeted delivery to the host immune organs, and helps in orchestrating protective immune induction in olive flounder, thus controlling parasite infection.


Assuntos
Quitosana , Doenças dos Peixes , Linguado , Oligoimenóforos , Parasitos , Animais , Doenças dos Peixes/parasitologia , Microesferas , Vacinas de Produtos Inativados
2.
Neuroradiology ; 65(1): 207-214, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36156109

RESUMO

INTRODUCTION: Deep learning-based MRI reconstruction has recently been introduced to improve image quality. This study aimed to evaluate the performance of deep learning reconstruction in pediatric brain MRI. METHODS: A total of 107 consecutive children who underwent 3.0 T brain MRI were included in this study. T2-weighted brain MRI was reconstructed using the three different reconstruction modes: deep learning reconstruction, conventional reconstruction with an intensity filter, and original T2 image without a filter. Two pediatric radiologists independently evaluated the following image quality parameters of three reconstructed images on a 5-point scale: overall image quality, image noisiness, sharpness of gray-white matter differentiation, truncation artifact, motion artifact, cerebrospinal fluid and vascular pulsation artifacts, and lesion conspicuity. The subjective image quality parameters were compared among the three reconstruction modes. Quantitative analysis of the signal uniformity using the coefficient of variation was performed for each reconstruction. RESULTS: The overall image quality, noisiness, and gray-white matter sharpness were significantly better with deep learning reconstruction than with conventional or original reconstruction (all P < 0.001). Deep learning reconstruction had significantly fewer truncation artifacts than the other two reconstructions (all P < 0.001). Motion and pulsation artifacts showed no significant differences among the three reconstruction modes. For 36 lesions in 107 patients, lesion conspicuity was better with deep learning reconstruction than original reconstruction. Deep learning reconstruction showed lower signal variation compared to conventional and original reconstructions. CONCLUSION: Deep learning reconstruction can reduce noise and truncation artifacts and improve lesion conspicuity and overall image quality in pediatric T2-weighted brain MRI.


Assuntos
Aprendizado Profundo , Humanos , Criança , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Neuroimagem , Movimento (Física) , Artefatos
3.
Pediatr Radiol ; 53(11): 2260-2268, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37488451

RESUMO

BACKGROUND: Craniofacial computed tomography (CT) is the diagnostic investigation of choice for craniosynostosis, but high radiation dose remains a concern. OBJECTIVE: To evaluate the image quality and diagnostic performance of an ultra-low-dose craniofacial CT protocol with deep learning reconstruction for diagnosis of craniosynostosis. MATERIALS AND METHODS: All children who underwent initial craniofacial CT for suspected craniosynostosis between September 2021 and September 2022 were included in the study. The ultra-low-dose craniofacial CT protocol using 70 kVp, model-based iterative reconstruction and deep learning reconstruction techniques was compared with a routine-dose craniofacial CT protocol. Quantitative analysis of the signal-to-noise ratio and noise was performed. The 3-dimensional (D) volume-rendered images were independently evaluated by two radiologists with regard to surface coarseness, step-off artifacts and overall image quality on a 5-point scale. Sutural patency was assessed for each of six sutures. Radiation dose was compared between the two protocols. RESULTS: Among 29 patients (15 routine-dose CT and 14 ultra-low-dose CT), 23 patients had craniosynostosis. The 3-D volume-rendered images of ultra-low-dose CT without deep learning showed decreased image quality compared to routine-dose CT. The 3-D volume-rendered images of ultra-low-dose CT with deep learning reconstruction showed higher noise level, higher surface coarseness but decreased step-off artifacts, comparable signal-to-noise ratio and overall similar image quality compared to the routine-dose CT images. Diagnostic performance for detecting craniosynostosis at the suture level showed no significant difference between ultra-low-dose CT without deep learning reconstruction, ultra-low-dose CT with deep learning reconstruction and routine-dose CT. The estimated effective radiation dose for the ultra-low-dose CT was 0.05 mSv (range, 0.03-0.06 mSv), a 95% reduction in dose over the routine-dose CT at 1.15 mSv (range, 0.54-1.74 mSv). This radiation dose is comparable to 4-view skull radiography (0.05-0.1 mSv) and lower than previously reported effective dose for craniosynostosis protocols (0.08-3.36 mSv). CONCLUSION: In this pilot study, an ultra-low-dose CT protocol using radiation doses at a level similar to skull radiographs showed preserved diagnostic performance for craniosynostosis, but decreased image quality compared to the routine-dose CT protocol. However, by combining the ultra-low-dose CT protocol with deep learning reconstruction, image quality was improved to a level comparable to the routine-dose CT protocol, without sacrificing diagnostic performance for craniosynostosis.


Assuntos
Craniossinostoses , Aprendizado Profundo , Criança , Humanos , Projetos Piloto , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Craniossinostoses/diagnóstico por imagem , Crânio , Algoritmos
4.
Fish Shellfish Immunol ; 127: 843-854, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35843523

RESUMO

The present study was conducted to assess the protective efficacy of a trivalent oral vaccine containing chitosan-PLGA encapsulated inactivated viral haemorrhagic septicemia virus (VHSV), Streptococcus parauberis serotype I and Miamiensis avidus antigens, followed by its oral (incorporated in feed) administration to olive flounder (Paralichthys olivaceus) fingerlings for a period of 15-consecutive days. After 35 days of initial vaccination, three separate challenge studies were conducted at the optimal temperature of the targeted pathogens using an intraperitoneal injection route. RPS analysis revealed moderate protection in the immunized group against all the three pathogens viz., VHSV (53.30% RPS), S. parauberis serotype-I (33.30% RPS), and M. avidus (66.75% RPS), as compared to the respective non-vaccinated challenge (NVC) control group. In addition, the immunized fish demonstrated significantly (p < 0.05) higher specific antibody titres in serum and significant (p < 0.05) upregulation in the transcript levels of immune genes of Igs (IgM, IgT, pIgR), TLRs (TLR 2, TLR 7), cytokines (IL-1ß, IL-8) and complement pathway (C3) in the mucosal and systemic tissues than those of NVC control fish, suggesting orchestration of pathogen-specific host immune responses thereby favouring its combativeness against the three pathogens. The expression dynamics of IFN-γ, Mx, caspase 3 genes post VHSV challenge; IFN-γ, TLR 2, caspase 1 genes post S. parauberis serotype I challenge and CD-8α, IL-10, TNF-α genes post M. avidus challenge further substantiates the efficacy of the vaccine in stimulating antiviral, antibacterial and antiparasitic immune responses in the host resulting in their better survival. The findings from the present study reflect that the formulated trivalent oral vaccine incorporating VHSV, S. parauberis serotype I and M. avidus antigens can be a promising prophylactic strategy to prevent the associated disease outbreaks in olive flounder.


Assuntos
Quitosana , Doenças dos Peixes , Linguado , Septicemia Hemorrágica Viral , Septicemia Hemorrágica , Novirhabdovirus , Oligoimenóforos , Vacinas Virais , Animais , Doenças dos Peixes/prevenção & controle , Septicemia Hemorrágica Viral/prevenção & controle , Novirhabdovirus/fisiologia , Streptococcus , Receptor 2 Toll-Like
5.
Pediatr Radiol ; 52(11): 2197-2205, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36121497

RESUMO

BACKGROUND: Leg length discrepancy (LLD) is a common problem that can cause long-term musculoskeletal problems. However, measuring LLD on radiography is time-consuming and labor intensive, despite being a simple task. OBJECTIVE: To develop and evaluate a deep-learning algorithm for measurement of LLD on radiographs. MATERIALS AND METHODS: In this Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study, radiographs were obtained to develop a deep-learning algorithm. The algorithm developed with two U-Net models measures LLD using the difference between the bilateral iliac crest heights. For performance evaluation of the algorithm, 300 different radiographs were collected and LLD was measured by two radiologists, the algorithm alone and the model-assisting method. Statistical analysis was performed to compare the measurement differences with the measurement results of an experienced radiologist considered as the ground truth. The time spent on each measurement was then compared. RESULTS: Of the 300 cases, the deep-learning model successfully delineated both iliac crests in 284. All human measurements, the deep-learning model and the model-assisting method, showed a significant correlation with ground truth measurements, while Pearson correlation coefficients and interclass correlations (ICCs) decreased in the order listed. (Pearson correlation coefficients ranged from 0.880 to 0.996 and ICCs ranged from 0.914 to 0.997.) The mean absolute errors of the human measurement, deep-learning-assisting model and deep-learning-alone model were 0.7 ± 0.6 mm, 1.1 ± 1.1 mm and 2.3 ± 5.2 mm, respectively. The reading time was 7 h and 12 min on average for human reading, while the deep-learning measurement took 7 min and 26 s. The radiologist took 74 min to complete measurements in the deep-learning mode. CONCLUSION: A deep-learning U-Net model measuring the iliac crest height difference was possible on teleroentgenograms in children. LLD measurements assisted by the deep-learning algorithm saved time and labor while producing comparable results with human measurements.


Assuntos
Aprendizado Profundo , Ílio , Criança , Humanos , Ílio/diagnóstico por imagem , Perna (Membro) , Desigualdade de Membros Inferiores/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Eur Radiol ; 31(3): 1260-1267, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33471218

RESUMO

OBJECTIVES: Preoperative estimation of the insertion depth angle of cochlear implant (CI) electrodes is essential for surgical planning. The purpose of this study was to determine the cochlear size using preoperative CT and to investigate the correlation between cochlear size and insertion depth angle in morphologically normal cochlea. METHODS: Thirty-five children who underwent CI were included in this study. Cochlear duct length (CDL) and the diameter of the cochlear basal turn (distance A/B) on preoperative CT and the insertion depth angle of the CI electrode on postoperative radiographs were independently measured by two readers. Correlation between cochlear size and insertion depth angle was evaluated. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC). RESULTS: The mean CDL, distance A, and distance B of 70 ears were 36.20 ± 1.57 mm, 8.67 ± 0.42 mm, and 5.73 ± 0.32 mm, respectively. The mean insertion depth angle was 431.45 ± 38.42°. Interobserver agreements of CDL, distance A/B, and insertion depth angle were fair to excellent (ICC 0.864, 0.862, 0.529, and 0.958, respectively). Distance A (r = - 0.7643) and distance B (r = - 0.7118) showed a negative correlation with insertion depth angle, respectively (p < 0.0001). However, the correlation between CDL and insertion depth angle was not statistically significant (r = - 0.2333, p > 0.05). CONCLUSIONS: The CDL and cochlear distance can be reliably obtained from preoperative CT. Distance A can be used as a predictive marker for estimating insertion depth angle during CI surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Criança , Cóclea/diagnóstico por imagem , Ducto Coclear/cirurgia , Humanos , Tomografia Computadorizada por Raios X
7.
AJR Am J Roentgenol ; 214(6): 1369-1376, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32255688

RESUMO

OBJECTIVE. The purpose of this study was to evaluate the CT angiography (CTA) findings of pulmonary arteriovenous malformation (PAVMs) in patients with hereditary hemorrhagic telangiectasia and to correlate these findings with those of graded contrast-enhanced transthoracic echocardiography (CE-TTE). MATERIALS AND METHODS. A retrospective review was conducted of PAVMs visualized at CTA of patients with abnormal CE-TTE findings (3-point scale). Location, distribution, size, number, volume, grade, and relative attenuation (attenuation of PAVM divided by attenuation of aorta) of PAVMs were recorded. PAVMs were graded as follows on conventional and maximum-intensity-projection (MIP) images: 0, nodule, unlikely PAVM; 1, ground-glass opacity (GGO); 2, GGO with increased vascular network; 3, GGO or nodule with single vessel; 4, GGO or nodule with two or more vessels; 5, GGO or nodule with afferent and larger efferent vessels; 6, mature arteriovenous malformation. Correlation between PAVM grade and relative attenuation and between CTA variables and CE-TTE grades was assessed. RESULTS. Forty patients (median age, 14.9 years; range, 0.6-27.9 years) had 117 PAVMs at CTA: 107 peripheral, eight central, and two both peripheral and central. None of the PAVMs was diffuse. Median size and volume were 0.4 cm (range, 0.1-4.4 cm) and 0.031 mL (range, 0.0009-10.019 mL). At CTA, seven PAVMs were grade 1, five grade 2, 28 grade 3, 62 grade 4, two grade 5, and 13 grade 6. MIP images showed 39 of 117 PAVMs were higher grade. Statistically significant correlation was found between relative attenuation and PAVM grade (p < 0.001, r = 0.58) in 40 patients and between all CTA variables and CE-TTE (p < 0.05, strongest correlation with highest grades [p < 0.0001, r = 0.81]) in 32 patients. CONCLUSION. In children and young adults with hereditary hemorrhagic telangiectasia, grade 4 PAVMs were most common. Higher-grade PAVMs more often have right-to-left shunts.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Pulmão/irrigação sanguínea , Telangiectasia Hemorrágica Hereditária/complicações , Adolescente , Adulto , Criança , Pré-Escolar , Meios de Contraste , Ecocardiografia , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
8.
Fish Shellfish Immunol ; 91: 136-147, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31096061

RESUMO

Viral haemorrhagic septicaemia virus (VHSV), a (-) ssRNA virus belonging to the genus Novirhabdovirus of rhabdoviridae family, is the aetiological agent of viral haemorrhagic septicaemia (VHS) disease which causes huge economic losses in farmed olive flounder (Paralichthys olivaceus) and significant mortalities among several other marine fish species in Korea, Japan, and China. Previously, we developed an inactivated vaccine viz., formalin-inactivated VHSV mixed with squalene as adjuvant which was effective in conferring protective immunity (58-76% relative percentage survival) against VHSV but the mode of administration was intraperitoneal injection which is not feasible for small sized fingerling fish. To overcome this limitation, we presently focused on replacing the injection route of vaccine delivery by oral and immersion routes. In this context, we encapsulated the inactivated VHSV vaccine with chitosan nanoparticles (CNPs-IV) by water-in-oil (W/O) emulsification method. After encapsulation, two sets of in vivo vaccination trials were conducted viz., preliminary trial-I and final trial-II. In preliminary trial-I, olive flounder fingerlings (10.5 ±â€¯1.7 g) were vaccinated with CNPs-IV by different delivery strategies involving oral and immersion routes (single/booster dose) followed by challenge with VHSV (1 × 106 TCID50 virus/fish) to evaluate an effective method amongst different applied delivery strategies. Subsequently, a final trial-II was conducted to better understand the immune mechanism behind the efficacy of the employed delivery strategy and also to further improvise the delivery mechanism with prime-boost (primary immersion and oral boosting) combination in order to improve the transient anti-VHSV response in the host. Evaluation of RPS analysis in trial-I revealed higher RPS of 46.7% and 53.3% in the CNPs-IV (immersion) and CNPs-IV (immersion/immersion) groups, respectively compared to 0% RPS in the CNPs-IV (oral) group and 20% RPS in the CNPs-IV (oral/oral) group when calculated against 100% cumulative mortality percentage in the NVC (non-vaccinated challenged) control group, whereas, in the trial-II, RPS of 60% and 66.6% were obtained for CNPs-IV (immersion/immersion) and CNPs-IV (immersion/oral) groups, respectively. In addition, specific (anti-VHSV) antibody titre in the fish sera, skin mucus and intestinal mucus of the immunized groups were significantly (p < 0.05) enhanced following vaccination. Furthermore, CNPs-IV immunized fish showed significant (p < 0.05) upregulation of different immune gene transcripts (IgM, IgT, pIgR, MHC-I, MHC-II, IFN-γ, and Caspase3) compared to control, in both the systemic (kidney) and mucosal (skin and intestine) immune compartments of the host post immunization as well as post challenge. To conclude, mucosal immunization with CNPs-IV vaccine can orchestrate an effective immunization strategy in organizing a coordinative immune response against VHSV in olive flounder thereby exhibiting higher protective efficacy to the host with minimum stress.


Assuntos
Quitosana/administração & dosagem , Doenças dos Peixes/prevenção & controle , Septicemia Hemorrágica Viral/prevenção & controle , Nanopartículas/administração & dosagem , Novirhabdovirus/imunologia , Vacinas Virais/administração & dosagem , Animais , Materiais Biocompatíveis/administração & dosagem , Composição de Medicamentos , Linguados , Linguado , Nanocápsulas , Distribuição Aleatória , Vacinas de Produtos Inativados/administração & dosagem , Vacinas de Produtos Inativados/imunologia , Vacinas Virais/imunologia
9.
J Nanosci Nanotechnol ; 19(8): 4495-4502, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-30913740

RESUMO

The functional hydrogel lens containing HEMA (2-hydroxyethylmethacrylate) was manufactured by thermal polymerization and heat treatment method after room temperature polymerization, respectively. In this study, HEMA, EGDMA (ethylene glycol dimethacrylate) and the initiator AIBN (azobisisobutyronitrile) were used for thermal copolymerization and the mixture was heated at 100 °C for 1 hour. And also, HEMA, EGDMA, the initiator and distilled water were used for heat treatment method after room temperature copolymerization and the mixture was heated 80 °C for 1 hour and then treated at 100 °C for 1 hour to produce the hydrogel ophthalmic lens by cast mold method. To make the functional hydrogel lens, ZnPC and platinum octaethyl porphyrin were used as additives. The measurements of the physical characteristics of the copolymerized material showed that refractive index and contact angle of sample was in the range of 1.4010∼1.4585 and 21.46∼87.28°, respectively. In case of heat treatment method after room temperature copolymerization, the refractive index and wettability of sample was higher than that of thermal polymerization. And also, the addition of ZnPC nanoparticles allowed the hydrogel lens to block UV-light. The absorbance value of solution in which the lens prepared by the heat treatment method was immersed were much lower than that of thermal polymerization, so it can be judged that the stabilization of produced polymer maintained well. Based on the results of this study, the produced optical lens can be considered to satisfy the basic requirements of optical lens and can be used effectively as an additive for functional ophthalmic lens material with high refractive index and wettability.

10.
Eur Radiol ; 26(4): 1149-58, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26255034

RESUMO

OBJECTIVES: To compare image quality and radiation dose between high-pitch mode (HPM) and low-pitch mode (LPM) CT in young children. MATERIALS AND METHODS: Forty-seven children (mean age 35.6 months; range, 0-126 months) underwent 49 CT examinations in HPM or LPM and were divided into high or low respiratory rate (RR) groups. A qualitative image quality was compared between the two modes. The volume CT dose index (CTDIvol) and dose-length product (DLP) were evaluated from the dose reports, and effective doses were assessed using a paediatric phantom. RESULTS: Image quality was generally better for HPM than LPM (diagnostic acceptance score, 4.00 vs. 3.46, P = 0.004); the difference was more prominent in the high RR group (4.00 vs. 3.22, P = 0.001). However, there was no significant difference in the low RR group. The mean DLP value was higher in HPM than LPM (29.48 mGy · cm vs. 23.46 mGy · cm, P = 0.022), while CTDIvol was not significantly different. The total effective radiation dose was 26 % higher in HPM than LPM (1.82 mSv vs. 1.44 mSv). CONCLUSIONS: LPM can be considered for paediatric lung evaluation in young children with low RRs to reduce radiation dose while maintaining favourable image quality. KEY POINTS: • Radiation exposure is higher on high-pitch "Flash spiral mode" than on low-pitch "X-CARE mode". • "Flash spiral mode" generally showed better image quality than "X-CARE mode". • Difference in image quality was more prominent in the high RR group. • There was no difference in image quality in the low RR group. • "X-CARE mode" should be considered in a limited population with low RRs.


Assuntos
Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Doses de Radiação , Taxa Respiratória/fisiologia , Tomografia Computadorizada Espiral/métodos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Imagens de Fantasmas
11.
Skeletal Radiol ; 45(10): 1449-52, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27502623

RESUMO

"Buttonholing" of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction.


Assuntos
Mau Alinhamento Ósseo/diagnóstico por imagem , Lesões no Cotovelo , Articulação do Cotovelo/diagnóstico por imagem , Luxações Articulares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Rádio (Anatomia)/anormalidades , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/lesões , Adolescente , Diagnóstico Diferencial , Feminino , Humanos
12.
Pediatr Radiol ; 45(6): 840-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25616364

RESUMO

BACKGROUND: Radial k-space sampling techniques have been shown to reduce motion artifacts in adult abdominal MRI. OBJECTIVE: To compare a T2-weighted radial k-space sampling MRI pulse sequence (BLADE) with standard respiratory-triggered T2-weighted turbo spin echo (TSE) in pediatric abdominal imaging. MATERIALS AND METHODS: Axial BLADE and respiratory-triggered turbo spin echo sequences were performed without fat suppression in 32 abdominal MR examinations in children. We retrospectively assessed overall image quality, the presence of respiratory, peristaltic and radial artifact, and lesion conspicuity. We evaluated signal uniformity of each sequence. RESULTS: BLADE showed improved overall image quality (3.35 ± 0.85 vs. 2.59 ± 0.59, P < 0.001), reduced respiratory motion artifact (0.51 ± 0.56 vs. 1.89 ± 0.68, P < 0.001), and improved lesion conspicuity (3.54 ± 0.88 vs. 2.92 ± 0.77, P = 0.006) compared to respiratory triggering turbo spin-echo (TSE) sequences. The bowel motion artifact scores were similar for both sequences (1.65 ± 0.77 vs. 1.79 ± 0.74, P = 0.691). BLADE introduced a radial artifact that was not observed on the respiratory triggering-TSE images (1.10 ± 0.85 vs. 0, P < 0.001). BLADE was associated with diminished signal variation compared with respiratory triggering-TSE in the liver, spleen and air (P < 0.001). CONCLUSION: The radial k-space sampling technique improved the quality and reduced respiratory motion artifacts in young children compared with conventional respiratory-triggered turbo spin-echo sequences.


Assuntos
Abdome , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Artefatos , Criança , Pré-Escolar , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Lactente , Masculino , Estudos Retrospectivos
13.
Pediatr Radiol ; 45(8): 1206-11, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25779826

RESUMO

BACKGROUND: Knowledge of the optimal lengths for central venous catheterization prior to the procedure may lessen the need for repositioning and prevent vascular complications. OBJECTIVE: To establish the optimal lengths for non-tunneled central venous catheter insertion through the right and left internal jugular veins. MATERIALS AND METHODS: We included 92 children who received US-guided central venous catheterization via right or left internal jugular veins in intensive care units. The calculated distance between the skin and carina was considered the optimal length for right and left internal jugular venous catheterization. Univariate and multivariate linear regression analyses was used to identify predictors. RESULTS: Age, height and weight showed significant correlations with optimal insertion lengths for right and left internal jugular vein approaches on univariate analysis, while height was the only significant independent predictor of optimal insertion length. CONCLUSION: The optimal insertion lengths (cm) suggested by our data are, for the right internal jugular vein 0.034 × height (cm) + 3.173, and for the left 0.072 × height (cm) + 2.113.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres Venosos Centrais , Veias Jugulares/diagnóstico por imagem , Ultrassonografia de Intervenção , Pesos e Medidas Corporais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
14.
Pediatr Radiol ; 45(1): 86-93, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24997791

RESUMO

BACKGROUND: Hemodynamic changes in the distal arteries during transfemoral catheterization in children have not been documented. OBJECTIVE: To evaluate arterial flow changes of the lower extremities ipsilateral to the puncture site using Doppler US during transfemoral cerebral angiography in children. MATERIALS AND METHODS: Twenty-seven children who underwent transfemoral cerebral angiography at our institution between April 2013 and August 2013 compose our study population. Doppler US was performed to evaluate diameters and peak systolic velocities of the common femoral artery and superficial femoral artery before and after femoral sheath insertion. Children were classified into three groups based on the spectral waveform changes of the superficial femoral artery after femoral sheath insertion. Thereafter, one-way ANOVA followed by the Bonferroni post-hoc comparisons test were performed to compare values among the groups. RESULTS: Mean common femoral artery and superficial femoral artery baseline diameters were 4.10 mm and 3.32 mm, and mean baseline peak systolic velocities were 218.26 and 166.51 cm/s, respectively. Fourteen of 27 children showed persistent triphasic flow in the superficial femoral artery (group 1); 7 children showed altered flow of biphasic (n = 3) or monophasic (n = 4) waveforms (group 2); and 6 children showed pulsus tardus et parvus pattern (group 3) after femoral sheath insertion. Mean baseline diameter of the common femoral artery and mean subtracted value between common femoral artery and femoral sheath size were significantly smaller in group 3 than the other groups. Size discrepancy between common femoral artery and femoral sheath was <1 mm in all cases of group 3. Superficial femoral artery diameter and peak systolic velocity significantly decreased after femoral sheath insertion in group 3 compared to groups 1 and 2. A significant skin temperature drop after sheath insertion in the ipsilateral lower extremity was noted in group 3 (-1.83°C), compared to groups 1 and 2 (+0.42 and -0.86°C, respectively). CONCLUSION: Changes in the spectral waveforms of superficial femoral arteries frequently occur in children during transfemoral cerebral angiography (13/27, 48%). Significant arterial flow disturbance was noted on Doppler US in children with a common femoral artery <1 mm larger than the femoral sheath diameter.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Cateterismo Periférico/métodos , Angiografia Cerebral/métodos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiologia , Ultrassonografia Doppler/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Ultrasonography ; 43(1): 57-67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38109893

RESUMO

PURPOSE: This study explored the feasibility of utilizing a deep learning artificial intelligence (AI) model to detect ileocolic intussusception on grayscale ultrasound images. METHODS: This retrospective observational study incorporated ultrasound images of children who underwent emergency ultrasonography for suspected ileocolic intussusception. After excluding video clips, Doppler images, and annotated images, 40,765 images from two tertiary hospitals were included (positive-to-negative ratio: hospital A, 2,775:35,373; hospital B, 140:2,477). Images from hospital A were split into a training set, a tuning set, and an internal test set (ITS) at a ratio of 7:1.5:1.5. Images from hospital B comprised an external test set (ETS). For each image indicating intussusception, two radiologists provided a bounding box as the ground-truth label. If intussusception was suspected in the input image, the model generated a bounding box with a confidence score (0-1) at the estimated lesion location. Average precision (AP) was used to evaluate overall model performance. The performance of practical thresholds for the modelgenerated confidence score, as determined from the ITS, was verified using the ETS. RESULTS: The AP values for the ITS and ETS were 0.952 and 0.936, respectively. Two confidence thresholds, CTopt and CTprecision, were set at 0.557 and 0.790, respectively. For the ETS, the perimage precision and recall were 95.7% and 80.0% with CTopt, and 98.4% and 44.3% with CTprecision. For per-patient diagnosis, the sensitivity and specificity were 100.0% and 97.1% with CTopt, and 100.0% and 99.0% with CTprecision. The average number of false positives per patient was 0.04 with CTopt and 0.01 for CTprecision. CONCLUSION: The feasibility of using an AI model to diagnose ileocolic intussusception on ultrasonography was demonstrated. However, further study involving bias-free data is warranted for robust clinical validation.

16.
Micromachines (Basel) ; 14(10)2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37893320

RESUMO

Since contact lenses directly contact the cornea, the surface roughness of the lens may cause various side effects. In addition, gold nanoparticles can realize a variety of colors and characteristics depending on their shape and size. In this study, the surface roughness of tinted lenses containing gold nanoparticles of various sizes was analyzed using atomic force microscopy (AFM) at aspect ratio(surface to volume ratio) ranging from 1:1 to 1:10. The characteristics of the lenses were then confirmed. As a result, tinted lenses with different colors depending on the size of the gold nanoparticles were manufactured. The surface roughness of the lens decreased with increasing size of the gold nanoparticles. However, at aspect ratio of 1:10, increase in surface roughness was observed. In addition, it was confirmed that the wettability and antibacterial properties of the lens had the same effect according to the average surface roughness value. Therefore, it was confirmed that the addition of gold nanoparticles reduced the surface roughness of the lens, which had a great effect on properties such as wettability and antimicrobial properties of the lens. The produced copolymer controls the surface roughness of the lens, and thus it is judged that it can be used as a material for various ophthalmology applications.

17.
Ultrasonography ; 42(2): 333-342, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36950778

RESUMO

PURPOSE: Subpial hemorrhage (SPH) is a subtype of intracranial hemorrhage characterized by damage to the adjacent brain parenchyma. The aim of this study was to describe the sonographic features of SPH in neonates. METHODS: The cranial ultrasound (US) findings of neonates with SPH confirmed by brain magnetic resonance imaging (MRI) were analyzed retrospectively. Initial and follow-up US and MRI scans were reviewed by two pediatric radiologists who were blinded to both clinical history and outcomes. The US features were compared with the MRI findings. RESULTS: Sixteen patients were included (median gestational age, 38 weeks; range, 26 to 40 weeks; 69% term). SPH was detected most often in the temporal lobe (63%), and multiple SPHs were found in seven of 16 neonates, based on MRI. Acute SPH with an underlying venous infarct (UVI) was detected on US in 15 of 16 patients: small or large fan-shaped hyperechoic lesions (n=7 and 4, respectively) and gyriform hyperechoic lesions (n=4). The sonographic yin-yang sign was observed in three of the four large fan-shaped SPH cases. The accompanying findings on US were intraventricular hemorrhage (four out of six MRI-confirmed cases), and concurrent periventricular venous infarcts (five out of nine MRI-confirmed cases). In five patients, subpial cysts were observed on follow-up US or MRI (n=4 and n=4, respectively). CONCLUSION: Acute SPH with UVI can appear as a peripheral fan-shaped or gyriform hyperechoic lesion on cranial US. SPH can be detected and suspected based on the US features of SPH with the accompanying findings.

18.
Pediatr Infect Dis J ; 42(5): 423-428, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36795583

RESUMO

BACKGROUND: The SARS-CoV-2 variants of concern exhibit distinct features in terms of transmissibility and virulence. This study compared the clinical characteristics of COVID-19 in children during pre-Delta, Delta and Omicron waves. METHODS: Medical records of 1163 children <19 years of age with COVID-19 admitted to a designated hospital in Seoul, South Korea, were analyzed. Clinical and laboratory findings during the pre-Delta (March 1, 2020, to June 30, 2021; 330 children), Delta (July 1, 2021, to December 31, 2021; 527 children) and Omicron (January 1, 2022, to May 10, 2022; 306 children) waves were compared. RESULTS: Children during the Delta wave were older and had a higher proportion of fever ≥5 days and pneumonia than children during the pre-Delta and Omicron waves. The Omicron wave was characterized by younger age and a higher proportion of fever ≥39.0 °C, febrile seizure and croup. More children <2 years of age and adolescents aged 10 to <19 years experienced neutropenia and lymphopenia, respectively, during the Delta wave. Children aged 2 to <10 years had a higher incidence of leukopenia and lymphopenia during the Omicron wave. CONCLUSIONS: Distinct features of COVID-19 were observed in children during the Delta and Omicron surges. Continuous scrutiny of the manifestations of variants of concern is needed for appropriate public health response and management.


Assuntos
COVID-19 , Linfopenia , Neutropenia , Adolescente , Humanos , Criança , Adulto Jovem , Adulto , Pré-Escolar , COVID-19/epidemiologia , SARS-CoV-2 , Febre
19.
J Korean Soc Radiol ; 84(3): 627-637, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37325003

RESUMO

Purpose: To investigate the effect of patient positioning on tendinosis grade, visible range, and infraspinatus tendon (IST) thickness, and to determine the feasibility of internal rotation (IR) position to assess IST on ultrasound (US). Materials and Methods: This study included 52 shoulders of 48 subjects who were evaluated for IST in three different positions: neutral position (N), IR, and position with the ipsilateral hand on the contralateral shoulder (HC). Two radiologists retrospectively graded IST tendinosis from grade 0 to grade 3 and the visible range from grade 1 to grade 4. The thickness of the IST was measured by another radiologist with a short-axis view. A generalized estimating equation was used for statistical analysis. Results: The tendinosis grades were higher in the HC position than in the IR position, with a cumulative odds ratio of 2.087 (0.004, 95% confidence interval [CI]: 1.268-3.433). The tendinosis grades in the HC position (p = 0.370) and IR position (p = 0.146) were not significantly different from those in the N position. The overall difference in IST thickness was significant (p < 0.001), but the visible range (p = 0.530) was not significantly different according to position. Conclusion: Patient positioning significantly affected the grade of tendinosis and thickness but not the visible range of the IST. The IR position is a feasible position for assessing the IST on US.

20.
Micromachines (Basel) ; 13(9)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36144074

RESUMO

Ginsenoside, known as a natural substance, is a saponin component in ginseng and has various effects, such as antibacterial, antioxidant, and anti-inflammatory effects. In addition, gold nanoparticles can realize various optical and physical properties according to particle size and shape. For polymer polymerization, ginsenoside and gold nanoparticles were used as additives and copolymerized with a basic silicone hydrogel material. As gold nanoparticles, spherical and rod-shaped particles were used, and basic physical properties, such as water content, refractive index, and wettability of the prepared ophthalmic lenses, were measured. As a result of measuring the physical properties of the resulting polymer, it was found that the contact angle decreased by about 1.6% to 83.1% as the addition ratio of ginsenoside increased. In addition, as the addition ratio of metal nanoparticles increased, the refractive index was found to increase regardless of the shape of the nanoparticles. In addition, in the case of water content, the spherical shape gradually decreased according to the addition ratio, while the rod shape gradually increased according to the addition ratio. Therefore, it was found that the addition of ginsenoside, known as a saponin-based natural substance, has excellent wettability, and gold nanoparticles with different shapes have different properties. Thus, it is judged that the resulting copolymer can be utilized as a variety of highly functional ophthalmic polymer materials with high refractive index and high wettability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA