RESUMO
BACKGROUND & AIMS: Reported rates of delayed bleeding (DB) after endoscopic resection using direct oral anticoagulants (DOACs) are high and heterogeneous. This large-scale multicenter study analyzed cases of DB after colorectal endoscopic submucosal dissection related to various types of DOACs in Japan (the ABCD-J study) with those associated with warfarin. METHODS: We retrospectively reviewed 1019 lesions in patients treated with DOACs and 459 lesions in patients treated with warfarin among 34,455 endoscopic submucosal dissection cases from 47 Japanese institutions between 2012 and 2021. The DB rate (DBR) with each DOAC was compared with that with warfarin. Risk factors for DB in patients treated with DOACs or warfarin were also investigated. RESULTS: The mean tumor sizes in the DOAC and warfarin groups were 29.6 ± 14.0 and 30.3 ± 16.4 mm, respectively. In the DOAC group, the DBR with dabigatran (18.26%) was significantly higher than that with apixaban (10.08%, P = .029), edoxaban (7.73%, P = .001), and rivaroxaban (7.21%, P < .001). Only rivaroxaban showed a significantly lower DBR than warfarin (11.76%, P = .033). In the multivariate analysis, heparin bridging therapy (odds ratio [OR], 2.18; 95% confidence interval [CI], 1.27-3.73, P = .005), rectal location (2.01, 1.28-3.16, P = .002), and procedure time ≥55 minutes (2.43, 1.49-3.95, P < .001) were significant risk factors for DB in the DOAC group. The DB risk in the DOAC group (OR, (95% CI)) was 2.13 (1.30-3.50) and 4.53 (2.52-8.15) for 1 and 2 significant risk factors, respectively. CONCLUSIONS: Dabigatran was associated with a higher DBR than other DOACs, and only rivaroxaban was associated with a significantly lower DBR than warfarin.
Assuntos
Fibrilação Atrial , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Varfarina , Rivaroxabana/efeitos adversos , Dabigatrana/efeitos adversos , Japão , Ressecção Endoscópica de Mucosa/efeitos adversos , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Anticoagulantes , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/complicações , Administração Oral , Fibrilação Atrial/complicaçõesRESUMO
BACKGROUND: Sodium picosulfate (SP)/magnesium citrate (MC) and polyethylene glycol (PEG) plus ascorbic acid are recommended by Western guidelines as laxative solutions for bowel preparation. Clinically, SP/MC has a slower post-dose defaecation response than PEG and is perceived as less cleansing; therefore, it is not currently used for major bowel cancer screening preparation. The standard formulation for bowel preparation is PEG; however, a large dose is required, and it has a distinctive flavour that is considered unpleasant. SP/MC requires a small dose and ensures fluid intake because it is administered in another beverage. Therefore, clinical trials have shown that SP/MC is superior to PEG in terms of acceptability. We aim to compare the novel bowel cleansing method (test group) comprising SP/MC with elobixibat hydrate and the standard bowel cleansing method comprising PEG plus ascorbic acid (standard group) for patients preparing for outpatient colonoscopy. METHODS: This phase III, multicentre, single-blind, noninferiority, randomised, controlled, trial has not yet been completed. Patients aged 40-69 years will be included as participants. Patients with a history of abdominal or pelvic surgery, constipation, inflammatory bowel disease, or severe organ dysfunction will be excluded. The target number of research participants is 540 (standard group, 270 cases; test group, 270 cases). The primary endpoint is the degree of bowel cleansing (Boston Bowel Preparation Scale [BBPS] score ≥ 6). The secondary endpoints are patient acceptability, adverse events, polyp/adenoma detection rate, number of polyps/adenomas detected, degree of bowel cleansing according to the BBPS (BBPS score ≥ 8), degree of bowel cleansing according to the Aronchik scale, and bowel cleansing time. DISCUSSION: This trial aims to develop a "patient-first" colon cleansing regimen without the risk of inadequate bowel preparation by using both elobixibat hydrate and SP/MC. TRIAL REGISTRATION: Japan Registry of Clinical Trials (jRCT; no. s041210067; 9 September 2021; https://jrct.niph.go.jp/ ), protocol version 1.5 (May 1, 2023).
Assuntos
Citratos , Ácido Cítrico , Dipeptídeos , Compostos Organometálicos , Picolinas , Polietilenoglicóis , Pólipos , Tiazepinas , Humanos , Catárticos , Pacientes Ambulatoriais , Ácido Ascórbico/efeitos adversos , Método Simples-Cego , Colonoscopia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto , Ensaios Clínicos Fase III como AssuntoRESUMO
BACKGROUND AND AIM: Endoscopic resection (ER) is widely performed to treat early colorectal cancer. However, additional surgery for pathological T1 colorectal cancer (pT1CRC) after ER is controversial because of the imprecise prediction of lymph node metastasis (LNM). Recently, several patients of pT1CRC with lymphoid follicular replacement (LFR) without LNM have been reported. This study aimed to investigate the clinicopathological features and risk of LNM in patients with pT1CRC with LFR. METHODS: We retrospectively analyzed patients who underwent ER or surgical resection and were diagnosed with pT1CRC between January 2010 and December 2020. We defined pT1CRC with LFR as the replacement of a part of the lymphoid follicular component within the submucosal area by adenocarcinoma, with no invasion into other submucosal areas. RESULTS: Among the 600 eligible patients, the incidence rate of pT1CRC with LFR was 6.7% (40/600). Patients with pT1CRC with LFR represented 14.3% (37/258) of the endoscopically treated patients and 0.9% (3/342) of the surgically treated patients. For patients with pT1CRC with LFR, 80.0% (32/40) had flat and depressed lesions, and 35.0% (14/40) had submucosal invasion depth ≥1000 µm. Patients with pT1CRC with LFR had negative lymphovascular invasion, differentiated type, and budding grade 1. In the median follow-up of 61 months, patients with pT1CRC with LFR had no LNM. CONCLUSIONS: The presence of LFR in pT1CRC may be associated with a low risk of LNM. In patients with pT1CRC with LFR, follow-up without additional surgery is possible even if the submucosal invasion depth is ≥1000 µm.
RESUMO
BACKGROUND: Endoscopic submucosal dissection (ESD) can be performed for superficial esophageal cancer. However, performing ESD for superficial esophageal cancer on a previous endoscopic resection scar may be difficult. METHODS: We compared the outcomes between ESD for superficial esophageal cancers on previous endoscopic resection scar (group A) and that for naïve lesions (group B). The study included outcomes of ESD, cumulative incidence of local failure, and predictors of the occurrence of local failure in ESD patients with squamous cell carcinoma (SCC). The outcome variables evaluated were en bloc resection rates, procedure times, adverse events, and overall survival rates. RESULTS: Overall, 220 lesions were extracted (groups A and B: 23 and 197 lesions, respectively). In groups A and B, the complete resection rates were 60.9 and 92.9% (P < 0.001), and the mean procedure times were 79 and 68 min (P = 0.15), respectively. The perforation rates in groups A and B were 4.3 and 1% (P = 0.28). The 1-year cumulative local failure rates were 22 and 1% (P < 0.001), respectively. In the multivariate Cox proportional hazards analysis, superficial esophageal SCC on a previous endoscopic resection scar was a strong predictor of local failure (hazard ratio = 21.95 [3.99-120.80], P < 0.001). The 3-year overall survival rates in groups A and B were 95 and 93% (P = 0.99), respectively. CONCLUSIONS: Repeated ESD on scar is an option for treating superficial esophageal SCC with an acceptable rate of adverse events. Because of the low complete resection rate and high local failure compared with conventional ESD, strict endoscopic follow-up is required after repeated esophageal ESD.
Assuntos
Carcinoma de Células Escamosas , Cicatriz , Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Humanos , Ressecção Endoscópica de Mucosa/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/patologia , Neoplasias Esofágicas/mortalidade , Feminino , Masculino , Cicatriz/etiologia , Idoso , Pessoa de Meia-Idade , Carcinoma de Células Escamosas do Esôfago/cirurgia , Carcinoma de Células Escamosas do Esôfago/patologia , Carcinoma de Células Escamosas do Esôfago/mortalidade , Carcinoma de Células Escamosas/cirurgia , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/mortalidade , Estudos Retrospectivos , Esofagoscopia/métodos , Esofagoscopia/efeitos adversos , Resultado do Tratamento , Duração da Cirurgia , Modelos de Riscos Proporcionais , Reoperação/estatística & dados numéricos , Reoperação/métodos , Taxa de Sobrevida , Falha de TratamentoRESUMO
In submucosal invasive adenocarcinoma of the esophagogastric junction (pT1b-SM AEG), the extent of tumor submucosal (SM) invasion is measured using the vertical depth of SM invasion with the muscularis mucosa. This study aimed to investigate whether tumor thickness and depth of invasion without accounting for muscularis mucosa were superior to the vertical depth of SM invasion as metastasis predictors. We enrolled patients with pT1b-SM AEG who underwent endoscopic resection or surgical resection (SR) at our institution between January 2011 and September 2019 and were followed up for ≥2 years. The relationship between metastasis and clinicopathological factors was examined. Metastasis was defined as pathologically confirmed lymph node metastasis in the surgical specimen or recurrence during follow-up. This study included 57 patients (44 men; median age, 72 years). Endoscopic resection and SR were performed in 16 and 41 patients, respectively. Nine patients were diagnosed with metastasis: five who underwent SR showed pathologically confirmed lymph node metastasis in the surgical specimens, and four experienced recurrences during a median follow-up of 48 months. Univariate analyses showed that tumor thickness was significantly associated with metastasis (P = 0.021), and the vertical depth of SM invasion (P = 0.48) and depth of invasion (P = 0.38) were not. Furthermore, in multivariate analysis, tumor thickness ≥2800 µm (odds ratio, 38.70; P = 0.013) was a significant predictor for metastasis. Tumor thickness may be a more convenient and useful predictor of metastasis in patients with pT1b-SM AEG than the vertical depth of SM invasion.
RESUMO
OBJECTIVES: Colonoscopy (CS) is an important screening method for the early detection and removal of precancerous lesions. The stool state during bowel preparation (BP) should be properly evaluated to perform CS with sufficient quality. This study aimed to develop a smartphone application (app) with an artificial intelligence (AI) model for stool state evaluation during BP and to investigate whether the use of the app could maintain an adequate quality of CS. METHODS: First, stool images were collected in our hospital to develop the AI model and were categorized into grade 1 (solid or muddy stools), grade 2 (cloudy watery stools), and grade 3 (clear watery stools). The AI model for stool state evaluation (grades 1-3) was constructed and internally verified using the cross-validation method. Second, a prospective study was conducted on the quality of CS using the app in our hospital. The primary end-point was the proportion of patients who achieved Boston Bowel Preparation Scale (BBPS) ≥6 among those who successfully used the app. RESULTS: The AI model showed mean accuracy rates of 90.2%, 65.0%, and 89.3 for grades 1, 2, and 3, respectively. The prospective study enrolled 106 patients and revealed that 99.0% (95% confidence interval 95.3-99.9%) of patients achieved a BBPS ≥6. CONCLUSION: The proportion of patients with BBPS ≥6 during CS using the developed app exceeded the set expected value. This app could contribute to the performance of high-quality CS in clinical practice.
RESUMO
OBJECTIVES: The resection of vertical margin-negative submucosally invasive colorectal cancer (CRC) relies on the pathological risk assessment of lymph node metastasis. However, no large-scale study has clarified the endoscopic resection (ER) outcome for submucosally invasive CRC, focusing on the vertical margin status. This retrospective study aimed to examine vertical margin involvement in ER for submucosally invasive CRC and explore the treatment consequences associated with vertical margin status. METHODS: We analyzed 395 submucosally invasive CRC cases in 389 patients who underwent ER at our hospital between 2008 and 2020. The presence of residual tumors and simultaneous lymph node metastasis in patients who underwent additional surgery was assessed and compared between the vertical incomplete ER and the vertical margin-negative groups. RESULTS: Among the patients, 270 were men, with a median age of 69 years. The vertical incomplete ER rate was 21.5%, with positive vertical margins and unclear vertical margins identified in 12.2% and 9.3% of the cases, respectively. Among 154 patients who underwent additional surgery after ER, the vertical incomplete ER group had a significantly higher residual tumor rate than the vertical margin-negative group (P = 0.001). The vertical incomplete ER group had a significantly higher lymph node metastasis rate than the vertical margin-negative group (P = 0.029). CONCLUSION: This study clarified the substantial risk of vertical incomplete ER in submucosally invasive CRC and revealed the high risk of residual tumor and lymph node metastasis in vertical incomplete ER for submucosal CRC.
Assuntos
Neoplasias Colorretais , Masculino , Humanos , Idoso , Feminino , Metástase Linfática , Estudos Retrospectivos , Neoplasia Residual/cirurgia , Medição de Risco , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Fatores de RiscoRESUMO
OBJECTIVES: There are several types of colorectal cancer (CRC) according to the detection methods and intervals, including interval CRC (iCRC) and postcolonoscopy CRC (PCCRC). We aimed to examine their proportions and characteristics. METHODS: We conducted a multicenter prospective study using questionnaires in Japan ("C-DETECT study"), in which differences in CRC characteristics according to detection methods and intervals were examined from consecutive adult patients. Because the annual fecal immunochemical test (FIT) was used in population-based screening, the annual FIT-iCRC was assessed. RESULTS: In total, 1241 CRC patients (1064 with invasive CRC) were included. Annual FIT-iCRC (a), 3-year PCCRC (b), and CRC detected within 1 year after a positive FIT with noncompliance to colonoscopy (c) accounted for 4.5%, 7.0%, and 3.9% of all CRCs, respectively, and for 3.9%, 5.4%, and 4.3% of invasive CRCs, respectively. The comparison among these (a, b, c) and other CRCs (d) demonstrated differences in the proportions of ≥T2 invasion ([a] 58.9%, [b] 44.8%, [c] 87.5%, [d] 73.0%), metastasis ([a] 33.9%, [b] 21.8%, [c] 54.2%, [d] 43.9%), right-sided CRC ([a] 42.9%, [b] 40.2%, [c] 18.8%, [d] 28.6%), and female sex ([a] 53.6%, [b] 49.4%, [c] 27.1%, [d] 41.6%). In metastatic CRC, (a) and (b) showed a higher proportions of BRAF mutations ([a] [b] 12.0%, [c] [d] 3.1%). CONCLUSIONS: Annual FIT-iCRC and 3-year PCCRC existed in nonnegligible proportions. They were characterized by higher proportions of right-sided tumors, female sex, and BRAF mutations. These findings suggest that annual FIT-iCRC and 3-year PCCRC may have biological features different from those of other CRCs.
Assuntos
Colonoscopia , Neoplasias Colorretais , Detecção Precoce de Câncer , Sangue Oculto , Humanos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Feminino , Masculino , Japão , Estudos Prospectivos , Detecção Precoce de Câncer/métodos , Pessoa de Meia-Idade , Idoso , Inquéritos e Questionários , Fatores de Tempo , Programas de Rastreamento/métodos , População do Leste AsiáticoRESUMO
OBJECTIVES: We aimed to evaluate the efficacy of texture and color enhancement imaging (TXI), which allows the acquisition of brighter images with enhanced color and surface structure in colorectal polyp detection compared to white light imaging. METHODS: Patients who underwent colonoscopy with repeated ascending colon observation using TXI and white light imaging between August 2020 and January 2021 were identified in three institutions. The outcomes included the mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and ascending colonic adenoma miss rate (Ac-AMR). Logistic regression was used to determine the effects of the variables on the outcomes. RESULTS: We included 1043 lesions from 470 patients in the analysis. The MAP, ADR, flat polyp detection rate, and Ac-AMR in TXI and white light imaging were 1.5% (95% confidence interval 1.3-1.6%) vs. 1.0% (0.9-1.1%), 58.2% (51.7-64.6%) vs. 46.8% (40.2-53.4%), 66.2% (59.8-72.2%) vs. 49.8% (43.2-56.4%), and 17.9% (12.1-25.2%) vs. 28.2% (20.0-37.6%), respectively. TXI, age, withdrawal time, and endoscopy type were identified as significant factors affecting the MAP and the ADR using multivariate regression analysis. CONCLUSIONS: Our study indicates that TXI improve the detection of colorectal neoplastic lesions. However, prospective randomized trials are required to confirm these findings.
Assuntos
Adenoma , Neoplasias do Colo , Pólipos do Colo , Neoplasias Colorretais , Humanos , Estudos Prospectivos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Colonoscopia/métodos , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Adenoma/diagnóstico por imagem , Adenoma/patologia , CorRESUMO
OBJECTIVES: Endoscopy poses a high risk of severe acute respiratory syndrome coronavirus 2 infection for medical personnel due to the dispersal of aerosols from the patient. We investigated the location and size of droplets generated during esophagogastroduodenoscopy (EGD) and endoscopic submucosal dissection (ESD), the contamination of the surrounding area before and after the procedures, and the effectiveness of using an extraoral suction device (Free arm arteo; TOKYO GIKEN, Inc., Tokyo, Japan). METHODS: Patients who consented to the study and underwent EGD or ESD between December 8, 2020, and April 15, 2021, at the National Cancer Center East Hospital were included. Adenosine triphosphate (ATP) hygiene monitoring tests and a particle counter were used for measurements. RESULTS: Assessments were performed on 22 EGD and 15 ESD cases. ATP hygiene monitoring tests showed significant elevations at three sites near the patient, and two sites 1.5 m away, for EGD, and at four sites near the patient and 1.5 m away for ESD. In both ESD and EGD, extraoral suction devices reduced the extent of the contamination. Particles <5 µm in size were generated during endoscopic procedures and dispersed from both the forceps hole and the patient's mouth. The extraoral suction device did not reduce the number of particles generated. CONCLUSIONS: During endoscopic procedures, cleaning the surrounding environment is important in addition to standard precautions the endoscopist and caregivers take. The use of extraoral suction devices can also potentially reduce contamination of the surrounding environment.
Assuntos
COVID-19 , Ressecção Endoscópica de Mucosa , Humanos , Estudos Prospectivos , Sucção , COVID-19/prevenção & controle , Aerossóis e Gotículas Respiratórios , Endoscopia , Ressecção Endoscópica de Mucosa/métodos , Resultado do TratamentoRESUMO
OBJECTIVES: The incidence of colorectal neuroendocrine tumors (NETs) has increased with colorectal cancer screening programs and increased colonoscopies. The management of colorectal NETs has recently shifted from radical surgery to endoscopic resection. We aimed to evaluate the short-term outcomes of various methods of endoscopic resection for colorectal NETs. METHODS: Among those registered in the C-NET STUDY, patients with colorectal NETs who underwent endoscopic treatment as the initial therapy were included. Short-term outcomes, such as the en bloc resection rate and R0 resection (en bloc resection with tumor-free margin) rate, were analyzed based on treatment modalities. RESULTS: A total of 472 patients with 477 colorectal NETs received endoscopic treatment. Of these, 418 patients with 421 lesions who met the eligibility criteria were included in the analysis. The median age of the patients was 55 years, and 56.9% of them were men. The lower rectum was the most commonly affected site (88.6%), and lesions <10 mm accounted for 87% of the cases. Endoscopic submucosal resection with a ligation device (ESMR-L, 56.5%) was the most common method, followed by endoscopic submucosal dissection (ESD, 31.4%) and endoscopic mucosal resection using a cap (EMR-C, 8.5%). R0 resection rates <10 mm were 95.5%, 94.8%, and 94.3% for ESMR-L, ESD, and EMR-C, respectively. All 16 (3.8%) patients who developed treatment-related complications could be treated conservatively. Overall, 23 (5.5%) patients had incomplete resection without independent clinicopathological risk factors. CONCLUSION: ESMR-L, ESD, and EMR-C were equally effective and safe for colorectal NETs with a diameter <10 mm.
RESUMO
BACKGROUND: Salvage endoscopic therapy, including endoscopic resection (ER) and photodynamic therapy (PDT), is effective for esophageal squamous cell carcinoma (ESCC) in local failure after chemoradiotherapy (CRT). Resection with pathologically vertical margin-negative (VM0) for ER and local complete response (L-CR) for PDT are important surrogate prognostic markers for each therapy's efficacy. We aimed to evaluate the usefulness of endoscopic ultrasound (EUS) in predicting the efficacy of salvage endoscopic therapy in local failure after CRT for ESCC. METHODS: We included patients who underwent EUS followed by ER or PDT for local failure after CRT or radiotherapy for ESCC from 2006 to 2020. We evaluated EUS findings associated with VM0 resection for ER and L-CR for PDT, which included the status of the outermost part of the submucosal layer, tumor thickness, and tumor invasion length into the muscularis propria (MP) layer. RESULTS: Thirty and 47 patients were enrolled into the ER and PDT groups, respectively. The VM0 resection rate in the ER group was 87% (26/30). The EUS findings associated with VM0 resection were tumor thickness < 2.3 mm (p = 0.01) and preserved hyperechoic line of the outermost part of the submucosa layer (p < 0.01). The L-CR rate in the PDT group was 69% (32/47). The EUS findings associated with L-CR were tumor thickness < 5.0 mm (p < 0.01) and tumor invasion length into the MP layer < 1.6 mm (p = 0.03). CONCLUSIONS: EUS can be useful in predicting the efficacy of salvage endoscopic treatment for local failure after CRT for ESCC.
Assuntos
Carcinoma de Células Escamosas , Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Humanos , Carcinoma de Células Escamosas do Esôfago/cirurgia , Neoplasias Esofágicas/patologia , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/cirurgia , Resultado do Tratamento , QuimiorradioterapiaRESUMO
BACKGROUND AND AIM: Endoscopic submucosal dissection (ESD) is performed as one of standard treatments for patients with early gastric cancer (EGC) and superficial esophageal squamous cancer (SESCC). A prototype of a flexible endoscope with a 3-D system has been recently developed. This study aimed to investigate the safety and feasibility of ESD using a 3-D flexible endoscope (3-D ESD) for EGC and SESCC. METHODS: This single-center, prospective, observational study enrolled patients who underwent planned 3-D ESD. The clinical outcomes, including the incidence of adverse events and treatment results, were analyzed. Visibility and manipulation during 3-D ESD were evaluated using a visual analog scale (VAS). We also evaluated the effect of the 3-D system on the endoscopist using VAS and the critical flicker fusion frequency (CFFF). RESULTS: We analyzed 47 EGC and 20 SESCC cases. There are no bleeding cases that required transfusion and perforation during 3-D ESD in both EGC and SESCC patients. However, the incidence of delayed bleeding and delayed perforation was 1.5% (one case) each. The mean VAS scores for recognizing the submucosal layer during the submucosal dissection, visual perception of blood vessel, and depth perception were 72.7 ± 22.2, 74.7 ± 21.8, and 78.2 ± 19.9, respectively. In contrast, the mean VAS score for manipulation was 25.4 ± 19.7. Among endoscopists, there was no significant difference in the VAS of eyestrain and headache before and after ESD, and there was no significant difference in the CFFF. CONCLUSION: The safety and feasibility of 3-D ESD for EGC and SESCC are acceptable in both patients and endoscopists.
Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Neoplasias Gástricas , Endoscópios , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Neoplasias Esofágicas/etiologia , Neoplasias Esofágicas/cirurgia , Estudos de Viabilidade , Mucosa Gástrica , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Neoplasias Gástricas/etiologia , Neoplasias Gástricas/cirurgia , Resultado do TratamentoRESUMO
OBJECTIVES: Salvage endoscopic resection is recommended when the local recurrence at primary site after chemoradiotherapy for esophageal squamous cell carcinoma is localized and superficial. This retrospective study aimed to comparatively analyse the short-term outcomes and local control of salvage endoscopic submucosal dissection versus salvage endoscopic mucosal resection for local recurrence after chemoradiotherapy or radiotherapy. METHODS: A total of 96 patients who underwent initial salvage endoscopic resection for cT1N0M0 local recurrence after chemoradiotherapy or radiotherapy for esophageal squamous cell carcinoma between December 1998 and August 2019 patients were assigned to either the salvage endoscopic submucosal dissection (40 patients; 40 lesions) or salvage endoscopic mucosal resection (56 patients; 56 lesions) group. We evaluated the en bloc and R0 resection rates, severe adverse events and local failure rate after salvage endoscopic resection. Multivariate analysis was conducted to identify risk factors of local failure after salvage endoscopic resection. RESULTS: The en bloc resection rate was significantly higher in the salvage endoscopic submucosal dissection group than in the salvage endoscopic mucosal resection group (95% versus 63%; P < 0.001). There were no differences in R0 resection rate between the two groups (73% versus 52%, P = 0.057). One patient (3%) in the salvage endoscopic submucosal dissection group had perforation. The 3-year cumulative local failure rate of salvage endoscopic mucosal resection was significantly higher than that of salvage endoscopic submucosal dissection (27% versus 5%, P = 0.032). In multivariate analysis, salvage endoscopic mucosal resection (hazard ratio: 2.7, P = 0.044) was the only independent risk factor of local failure after salvage endoscopic resection. CONCLUSIONS: Salvage endoscopic submucosal dissection is the effective treatment for local recurrence based on the short-term outcomes and local efficacy.
Assuntos
Carcinoma de Células Escamosas , Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Quimiorradioterapia/efeitos adversos , Ressecção Endoscópica de Mucosa/efeitos adversos , Neoplasias Esofágicas/patologia , Neoplasias Esofágicas/cirurgia , Carcinoma de Células Escamosas do Esôfago/complicações , Carcinoma de Células Escamosas do Esôfago/cirurgia , Humanos , Recidiva Local de Neoplasia/patologia , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Endoscopic submucosal dissection (ESD) is an optimal treatment for colorectal tumors; however, it is technically difficult, especially for non-experts. Therefore, a device that helps non-experts perform colorectal ESD would be beneficial. A double-balloon endolumenal interventional platform (DEIP) was recently developed to assist colorectal ESD through endoscope stabilization and traction. This study assessed the usefulness of colorectal ESD using the DEIP (DEIP-ESD) by endoscopists, including non-experts, in a living porcine model. METHODS: Two pigs were used to perform eight DEIP-ESD and eight conventional cap-assisted ESD (C-ESD) procedures. Three experts and five non-experts each resected one lesion using DEIP-ESD and one using C-ESD. We evaluated the treatment outcomes and performed stratified analyses between the experts and non-experts. RESULTS: Dissection speed was significantly faster in DEIP-ESD than in C-ESD (13.3 mm2/min vs 28.5 mm2/min, P = 0.002). However, the total procedure time did not differ significantly between DEIP-ESD and C-ESD. In the stratified analyses, the dissection speed of non-experts was significantly faster in DEIP-ESD than in C-ESD (10.9 mm2/min vs 25.1 mm2/min, P = 0.016), while that of experts increased in DEIP-ESD but to a lesser extent (19.1 mm2/min vs 28.8 mm2/min, P = 0.1). The total procedure time did not differ between DEIP-ESD and C-ESD for both experts and non-experts. The self-completion rate of non-experts also increased in DEIP-ESD. Moreover, the number of muscularis propria injuries induced by non-experts was fewer in DEIP-ESD than in C-ESD. CONCLUSIONS: DEIP could facilitate colorectal ESD by improving dissection efficiency without increasing adverse events, especially when performed by non-experts.
Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Animais , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Dissecação/métodos , Ressecção Endoscópica de Mucosa/métodos , Suínos , Tração , Resultado do TratamentoRESUMO
Depth diagnosis is extremely crucial in making a treatment choice between endoscopic resection and surgery in the early stages of cancers. Among several imaging modalities, we use magnifying endoscopy to diagnose lesions by close observation of the findings at mucosal surface layer. In combination with topical staining, magnifying endoscopy enables us to assess the definite pit structure, which referred to as magnifying chromoendoscopy (MCE). The pit pattern classification by MCE was proposed and is now widely accepted as the standard diagnostic criteria for colorectal lesions. Meanwhile, image enhanced endoscopy (IEE) represented by narrow-band imaging was developed to improve the visibility of surface and vascular findings without dyeing. Recent collaborative work performed by endoscopic experts in Japan yielded the unified diagnostic criteria, the Japan NBI Expert Team (JNET) classification, based on the findings of IEE with magnification. In this review, focusing on MCE and IEE with magnification, we aimed to give an outline of the pit pattern classification and the JNET classification, and further discuss their accuracy rate of depth diagnosis of early colorectal lesions by performing a review of the related literature. Both modalities have a high accuracy rate of nearly 90% for depth diagnosis. IEE with magnification is an ideal modality because it helps observe lesions without dye spraying; however, lesions with JNET type 2B have an inadequate diagnostic ability, which should be complemented by MCE. We conclude that accurate diagnosis is possible by examining lesions using both modalities properly to overcome the limitations of each modality.
Assuntos
Colonoscopia , Neoplasias Colorretais , Neoplasias Colorretais/diagnóstico por imagem , Corantes , Endoscopia Gastrointestinal , Humanos , Imagem de Banda EstreitaRESUMO
The virtual scale endoscope (VSE) is a new endoscope that helps estimate the size of neoplasms in the gastrointestinal tract. We compared the accuracy of polyp size estimation by VSE with that of visual estimation. A dual center prospective study was conducted in two Japanese academic endoscopy units. Ten endoscopists (five trainees and five experts) estimated the size of 20 simulated polyps in four colon phantoms during colonoscopy by two methods: conventional visual estimation and estimation by VSE. The primary endpoint was the relative accuracy in relation to true polyp size according to visual estimation and VSE estimation during colonoscopy. The secondary endpoint was the required time (the time needed to measure in each procedure). The mean values of the primary end-point were 62.5% for visual estimation and 84.0% for VSE estimation; hence the result differed significantly (95% confidence interval 18.3-24.7; P < 0.001). The mean of required times was significantly longer for estimation by VSE (6.4 min) than that by visual estimation (2.9 min; P < 0.001). The accuracy of colorectal polyp size estimation was superior with VSE than with visual estimation during colonoscopy. In the future, VSE should be evaluated in actual clinical settings, including the time required for size estimation.
Assuntos
Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/diagnóstico , Estudos Prospectivos , Colonoscopia/métodos , Colo , Neoplasias Colorretais/diagnósticoRESUMO
BACKGROUND: Artificial intelligence (AI) has made considerable progress in image recognition, especially in the analysis of endoscopic images. The availability of large-scale annotated datasets has contributed to the recent progress in this field. Datasets of high-quality annotated endoscopic images are widely available, particularly in Japan. A system for collecting annotated data reported daily could aid in accumulating a significant number of high-quality annotated datasets. AIM: We assessed the validity of using daily annotated endoscopic images in a constructed reporting system for a prototype AI model for polyp detection. METHODS: We constructed an automated collection system for daily annotated datasets from an endoscopy reporting system. The key images were selected and annotated for each case only during daily practice, not to be performed retrospectively. We automatically extracted annotated endoscopic images of diminutive colon polyps that had been diagnosed (study period March-September 2018) using the keywords of diagnostic information, and additionally collect the normal colon images. The collected dataset was devised into training and validation to build and evaluate the AI system. The detection model was developed using a deep learning algorithm, RetinaNet. RESULTS: The automated system collected endoscopic images (47,391) from colonoscopies (745), and extracted key colon polyp images (1356) with localized annotations. The sensitivity, specificity, and accuracy of our AI model were 97.0%, 97.7%, and 97.3% (n = 300), respectively. CONCLUSION: The automated system enabled the development of a high-performance colon polyp detector using images in endoscopy reporting system without the efforts of retrospective annotation works.
Assuntos
Inteligência Artificial , Pólipos do Colo , Colo , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Humanos , Estudos RetrospectivosRESUMO
OBJECTIVES: Photodynamic therapy (PDT) is an optional salvage treatment for local failure of esophageal squamous cell carcinoma (ESCC) after chemoradiotherapy; however, local failure after PDT sometimes occurs. In such cases, second PDT is sometimes attempted, but its outcomes remain unclear. This study aimed to evaluate the efficacy and safety of second PDT. METHODS: We enrolled patients who underwent PDT for local failure of ESCC after chemoradiotherapy. We retrospectively evaluated local-complete response (L-CR) rate and clinical outcomes of first and second PDT. The indications for PDT were lesions within the muscle layer, <3 cm in size, and <3/4 of the esophageal circumference; not suitable for salvage surgery; and absence of metastasis. Second PDT was avoided when lesions were apparently refractory to first PDT, e.g. persistence of submucosal tumor-like protruded component or rapid regrowth of tumor at the ulceration after first PDT. L-CR was defined as endoscopic disappearance of tumor and post-PDT ulcer and absence of cancer cells histologically. RESULTS: Among 82 patients who underwent first PDT, 27 underwent second PDT. The L-CR rates with first and second PDT were 63.0% and 40.7%, respectively. The 2-year overall survival rates after second PDT in patients with L-CR and local-nonCR were 79.5% and 40.5%, respectively. Five of 11 patients with L-CR survived without any recurrence. No grade ≥3 adverse events occurred. CONCLUSIONS: Second PDT demonstrated excellent safety and acceptable efficacy; therefore, it could be a useful treatment for local failure after first PDT.
Assuntos
Carcinoma de Células Escamosas , Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Fotoquimioterapia , Carcinoma de Células Escamosas/patologia , Neoplasias Esofágicas/patologia , Carcinoma de Células Escamosas do Esôfago/tratamento farmacológico , Humanos , Recidiva Local de Neoplasia/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Terapia de Salvação , Resultado do TratamentoRESUMO
BACKGROUND: The traction assisted (TA) method has reduced the technical difficulty associated with esophageal endoscopic submucosal dissection (ESD). However, it is unclear which factors associated with difficulty have been improved by the TA-ESD method. We aimed to evaluate and compare difficulty factors between conventional and TA-ESD. METHODS: We retrospectively enrolled patients treated by ESD from Apr 2010 to Jun 2014 for the conventional ESD cohort and from Jan 2016 to Dec 2019 for the TA-ESD cohort. Difficult cases were defined as; (1) ≥ 120 min ESD procedure time, (2) intraoperative perforation, or (3) piecemeal resection. We explored and compared the factors associated with technical difficulty in each cohort. RESULTS: The conventional and TA-ESD cohorts included 285 (299 lesions) and 387 (421 lesions) patients, respectively. For difficult cases, the conventional and TA-ESD cohorts had 91 (30%) and 71 (17%) lesions, respectively. Multivariate logistic regression showed that ≥ 30 mm lesion length (odds ratio (OR) 6.85, 95% confidence interval (CI) 3.47-13.50), lower esophagus (OR 2.37, 95% Cl 1.34-4.21), > 1/2 circumference (OR 2.26, 95% CI 1.28-3.99), and left wall (OR 2.72, 95% CI 1.42-5.20) in the conventional ESD cohort, and ≥ 30 mm lesion length (21.30, 95% CI 4.75-95.30), lower esophagus (OR 3.05, 95% CI 1.52-6.13), and > 1/2 circumference (OR 6.40, 95% CI 3.06-13.40) in the TA-ESD cohort, were independently associated with technical difficulty. CONCLUSIONS: TA-ESD can reduce the difficulty in cases including lesions in the left wall; however, cases in the lower esophagus and large lesions were still difficult to simplify.