Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
F1000Res ; 92020.
Artigo em Inglês | MEDLINE | ID: mdl-33604024

RESUMO

Background: Heart failure is a major health problem and progress in this field relies on better understanding of the mechanisms and development of novel therapeutics using animal models. The rat may be preferable to the mouse as a cardiovascular disease model due to its closer physiology to humans and due to its large size that facilitates surgical and monitoring procedures. However, unlike the mouse, genetic manipulation of the rat genome is challenging. Methods: Here we developed a simple, refined, and robust cardiac-specific rat transgenic model based on an adeno-associated virus (AAV) 9 containing a cardiac troponin T promoter. This model uses a single intraperitoneal injection of AAV and does not require special expertise or equipment. Results: We characterize the AAV dose required to achieve a high cardiac specific level of expression of a transgene in the rat heart using a single intraperitoneal injection to neonates. We show that at this AAV dose GFP expression does not result in hypertrophy, a change in cardiac function or other evidence for toxicity. Conclusions: The model shown here allows easy and fast transgenic based disease modeling of cardiovascular disease in the rat heart, and can also potentially be expanded to deliver Cas9 and gRNAs or to deliver small hairpin (sh)RNAs to also achieve gene knockouts and knockdown in the rat heart.


Assuntos
Dependovirus , Modelos Animais de Doenças , Vetores Genéticos , Insuficiência Cardíaca/genética , Animais , Dependovirus/genética , Regiões Promotoras Genéticas , Ratos , Ratos Transgênicos , Transgenes , Troponina T/genética
2.
Ann N Y Acad Sci ; 1080: 466-78, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17132802

RESUMO

A novel physiological cardiac assist device (PCAD), the LEV RAM assist device, which is synchronized with the failing heart ejection, was developed to improve the failing heart systolic and diastolic functions and cardiac energetics. The PCAD uses a single short cannula, which is inserted into the beating left ventricle (LV) by means of a specially designed device. Blood is ejected from the PCAD into the LV after the opening of the aortic valve and augments the cardiac stroke work. The same amount of blood is withdrawn from the LV into the PCAD, through the same cannula, during the diastole. The study aims to test the effects of the PCAD on cardiac energetics and coronary blood flow. Adult normal sheep were anesthetized and the heart was exposed by left thoracotomy. Pressures transducers (Millar Instruments, Inc., Houston, TX) were inserted into the LV and aorta. LV volume was measured by sonocrystals (Sonometrics Corp., London, Ontario, Canada) and impedance catheter (CD Lycom, Argonstrat 116 Zoetermeer, 2718 SP The Netherlands). Flowmeters (transonic) measured the cardiac output (CO) and the coronary arteries (left anterior descending (LAD) and circumflex) flows. A thin cannula was inserted into the coronary sinus and the oxygen content of the LV and the coronary sinus were determined (AVOXimeter-1000). Pressure-volume loops, myocardial energetics, and coronary flow were measured. The displaced PCAD volume was 11 mL. Four different levels of assist were studied by changing the frequency of the assist: (1) assist beat after three successive regular beats [1:4], (2) assist every third beat [1:3], (3) alternate assist and normal beat [1:2], and (4) continuous assist [1:1]. Cardiac output (CO) and stroke volume (SV) increased proportionally with increasing frequency of assist. Systolic mechanical efficiency of the PCAD was above 90%. Simultaneously, the PCAD decreased the end-diastolic volume (EDV; diastolic unloading). The PCAD increased coronary flow and decreased cardiac arterial-venous O(2) difference. We conclude that the PCAD efficiently augments CO and stroke work, decreases preload, and decreases the coronary arterial-venous O(2) difference; all these may expedite cardiac reverse remodeling, and promote recovery of function and eventual easy explanation of the device.


Assuntos
Coração Auxiliar , Coração/fisiologia , Animais , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA