RESUMO
STUDY OBJECTIVE: The aim of this study was to investigate the efficacy of a two-step patient blood management (PBM) program in red blood cell (RBC) transfusion requirements among patients undergoing elective cardiopulmonary bypass (CPB) surgery. DESIGN: Prospective, non-randomized, two-step protocol design. SETTING: Cardiac surgery department of Clinique Pasteur, Toulouse, France. PATIENTS: 897 patients undergoing for elective CPB surgery. INTERVENTIONS: We conducted a two-steps protocol: PBMe and PBMc. PBMe involved a short quality improvement program for health care workers, while PBMc introduced a systematic approach to pre- and postoperative correction of deficiencies, incorporating iron injections, oral vitamins, and erythropoiesis-stimulating agents. MEASUREMENTS: The PBM program's effectiveness was evaluated through comparison with a pre-PBM retrospective cohort after propensity score matching. The primary objective was the proportion of patients requiring RBC transfusions during their hospital stay. Secondary objectives were also analyzed. MAIN RESULTS: After matching, 343 patients were included in each group. Primary outcomes were observed in 35.7% (pre-PBM), 26.7% (PBMe), and 21.1% (PBMc) of patients, resulting in a significant reduction (40.6%) in the overall RBC transfusion rate. Both the PBMe and PBMc groups exhibited significantly lower risks of RBC transfusion compared to the pre-PBM group, with adjusted odds ratios of 0.59 [95% CI 0.44-0.79] and 0.44 [95% CI 0.32-0.60], respectively. Secondary endpoints included reductions in transfusions exceeding 2 units, total RBC units transfused, administration of allogeneic blood products, and total bleeding volume recorded on Day 1. There were no significant differences noted in mortality rates or the duration of hospital stays. CONCLUSIONS: This study suggests that health care education and systematic deficiency correction are associated with reduced RBC transfusion rates in elective CPB surgery. However, further randomized, controlled studies are needed to validate these findings and refine their clinical application.
Assuntos
Ponte Cardiopulmonar , Procedimentos Cirúrgicos Eletivos , Transfusão de Eritrócitos , Assistência Perioperatória , Humanos , Transfusão de Eritrócitos/estatística & dados numéricos , Masculino , Feminino , Estudos Prospectivos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Idoso , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Ponte Cardiopulmonar/efeitos adversos , Anemia Ferropriva/prevenção & controle , Hematínicos/administração & dosagem , Anemia/terapia , Melhoria de Qualidade , Deficiências de Ferro , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos , Ferro/administração & dosagem , França , Tempo de Internação/estatística & dados numéricosRESUMO
INTRODUCTION: Recent expert consensus guidelines mention that one of the principles for infected device replacement following removal is to "reevaluate carefully if there is a continued need for a new cardiac device replacement." This is a Class I recommendation, which nevertheless suffers from a very low level of evidence (level of evidence C), since no study has revisited the systematic practice of reimplanting the same device based on a meticulous clinical reassessment. In the present paper, we examined the safety of withholding the implantation of pacing systems in selected patients. METHODS AND RESULTS: Between January 2005 and December 2007, 188 consecutive patients underwent extractions of infected pacing systems at 2 medical centers. "Low-risk" patients were identified by (1) a spontaneous heart rate >45 bpm, (2) no symptomatic asystole during monitoring, (3) QRS duration <120 ms when history of AV block was noted, (4) no high-degree AV block during continuous monitoring. They remained device-free, unless an adverse clinical event occurred mandating the reimplantation. The primary study endpoint was rate of sudden death and syncope after a 12-month follow-up. Among the 74 (39.4%) "low-risk" patients, a single patient suffered a bradycardia-related syncopal event corresponding to a 1.3% (95% CI, 0.0-3.9) rate of primary endpoint. Pacing systems were also reimplanted in 24 patients (32.4%) for syncope (n = 1), nonsevere bradycardia-reated symptoms (n = 17), cardiac resynchronization (n = 2), and for reassurance in 4 asymptomatic patients. CONCLUSION: After removal of infected pacing systems, these preliminary data demonstrated that a strategy of nonsystematic device reimplantation associated with close surveillance was safe in "low-risk" patients, allowing the administration of antimicrobials in a device-free state.
Assuntos
Marca-Passo Artificial , Implantação de Prótese , Infecções Relacionadas à Prótese/cirurgia , Idoso , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Bloqueio Atrioventricular/complicações , Morte Súbita Cardíaca/epidemiologia , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Implantação de Prótese/efeitos adversos , Reoperação , Medição de Risco , Choque Séptico/complicações , Resultado do TratamentoRESUMO
Anaemia and iron deficiency are frequent in patients scheduled for cardiac surgery. Perioperative patient blood management (PBM) is widely recommended in current practice guidelines. The aim of this protocol is to analyse the effect of a global perioperative PBM programme on the red blood cell (RBC) transfusion ratio, morbidities and rehabilitation score in elective cardiac surgery.This study is a prospective, single-centre trial with a 2-step protocol, A and B, as follows: A: non-drug intervention: the caregiver is given a blood management educational programme; B: drug intervention: systematic correction of perioperative iron, vitamin deficiencies, and anaemia. This study was designed to enrol 900 patients (500 in group A and 400 in group B) in a rolling period starting at anaesthesia consultation and ending 3 months after surgery. The primary objective was a 20% reduction in RBC transfusion after implementation of PBM programmes (protocol A + B) when compared to our previous transfusion ratio in the first half of 2018 (30.4% vs 38%). The secondary objectives were to evaluate the impact for each step of the study on the RBC transfusion rate, morbidity and the quality of postoperative rehabilitation.The strength of this study is its evaluation of the effect of a global PBM programme on RBC transfusion in cardiac surgery through a 2-step protocol. We aim to assess for the first time the impact of non-drug and drug interventions on RBC transfusion, comorbidities and delayed rehabilitation parameters. TRIALS REGISTRATIONS: ClinicalTrials.gov, NCT04040023: registered 29 July 2019.
RESUMO
PURPOSE: We measured the proportion of intravascular leads, which can be extracted by simple traction versus with newer techniques, and examined the overall safety and success rate of lead extractions. METHODS: Between January 2005 and December 2007, 311 consecutive patients (mean age = 70 +/- 14 years, 79% men) underwent extractions of 250 atrial, 318 ventricular, and 22 coronary sinus leads, in the surgical facilities of two experienced medical centers, under general anesthesia, at a mean of 7.2 +/- 5.1 years (range 0.1-27.0) after lead implantation. Infection was the indication for extraction in 67.5% of cases. Complementary techniques were used when simple extraction with a locking stylet was unsuccessful. RESULTS: Simple traction, with or without a locking stylet, allowed the complete removal in 27.0% (95% confidence interval [CI] 22.1-31.9) of patients. A mechanical sheath, laser sheath, and/or lasso catheter were used in the remaining patients. The overall extraction success rate was 89.7% (95% CI 86.3-93.1). There was one procedure-related death (0.3%; 95% CI 0.0-1.0). Among five other deaths occurring within 10 days after the procedure, four were due to septic shock. Duration of lead implantation was the strongest independent predictor of major adverse events (P = 0.002) and incomplete lead extraction (P = 0.005). CONCLUSION: In contrast with simple traction, advanced techniques allowed the complete extraction of nearly 90% of leads. In experienced hands and with surgical back-up, these techniques were safe. Patients presenting with infected implanted cardiac devices suffered a high rate of major adverse despite complete extraction of the lead(s).