Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ultrason Imaging ; 40(2): 67-83, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28832256

RESUMO

Estimation of strain in tendons for tendinopathy assessment is a hot topic within the sports medicine community. It is believed that, if accurately estimated, existing treatment and rehabilitation protocols can be improved and presymptomatic abnormalities can be detected earlier. State-of-the-art studies present inaccurate and highly variable strain estimates, leaving this problem without solution. Out-of-plane motion, present when acquiring two-dimensional (2D) ultrasound (US) images, is a known problem and may be responsible for such errors. This work investigates the benefit of high-frequency, three-dimensional (3D) US imaging to reduce errors in tendon strain estimation. Volumetric US images were acquired in silico, in vitro, and ex vivo using an innovative acquisition approach that combines the acquisition of 2D high-frequency US images with a mechanical guided system. An affine image registration method was used to estimate global strain. 3D strain estimates were then compared with ground-truth values and with 2D strain estimates. The obtained results for in silico data showed a mean absolute error (MAE) of 0.07%, 0.05%, and 0.27% for 3D estimates along axial, lateral direction, and elevation direction and a respective MAE of 0.21% and 0.29% for 2D strain estimates. Although 3D could outperform 2D, this does not occur in in vitro and ex vivo settings, likely due to 3D acquisition artifacts. Comparison against the state-of-the-art methods showed competitive results. The proposed work shows that 3D strain estimates are more accurate than 2D estimates but acquisition of appropriate 3D US images remains a challenge.


Assuntos
Imageamento Tridimensional/métodos , Imagens de Fantasmas , Tendões/diagnóstico por imagem , Ultrassonografia/métodos , Estudos de Viabilidade , Modelos Biológicos , Reprodutibilidade dos Testes
2.
Dent Traumatol ; 30(5): 400-405, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23998296

RESUMO

A 24-year-old female patient presented with complaint of palatal swelling and a sinus tract facial to tooth #22. She reported an injury to the tooth 15 years earlier and no recollection of treatment, although there was evidence of an endodontic access into the crown. Radiographically the root appeared to have stopped developing, and it was associated with a large periapical lesion. After 3 unsuccessful attempts at apexification using calcium hydroxide (CH), further examination including use of cone-beam computed tomography (CBCT) was carried out. The latter allowed for better evaluating the situation and for better planning a more comprehensive treatment plan to include surgical removal of the apical lesion. The large radiolucent area extended from tooth #21 to #23. Using a dedicated software tool developed to be used in conjunction with CBCT, volumetric assessment of the lesion was carried out for healing follow up. The root end was filled from the apical direction with newly developed accelerated silicate cement 4-5 mm into the apical part of the canal. Subsequently, the rest of the canal was filled with the same type of cement. At the 1-year postsurgical follow up, the tooth remained asymptomatic, and using the CBCT volumetric program, bony healing could be demonstrated.


Assuntos
Traumatismos Dentários/terapia , Adulto , Feminino , Humanos , Adulto Jovem
3.
Respir Res ; 14: 131, 2013 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-24251975

RESUMO

BACKGROUND: Spirometric parameters are the mainstay for diagnosis of COPD, but cannot distinguish airway obstruction from emphysema. We aimed to develop a computer model that quantifies airway collapse on forced expiratory flow-volume loops. We then explored and validated the relationship of airway collapse with computed tomography (CT) diagnosed emphysema in two large independent cohorts. METHODS: A computer model was developed in 513 Caucasian individuals with ≥15 pack-years who performed spirometry, diffusion capacity and CT scans to quantify emphysema presence. The model computed the two best fitting regression lines on the expiratory phase of the flow-volume loop and calculated the angle between them. The collapse was expressed as an Angle of collapse (AC) which was then correlated with the presence of emphysema. Findings were validated in an independent group of 340 individuals. RESULTS: AC in emphysema subjects (N = 251) was significantly lower (131° ± 14°) compared to AC in subjects without emphysema (N = 223), (152° ± 10°) (p < 0.0001). Multivariate regression analysis revealed AC as best indicator of visually scored emphysema (R2 = 0.505, p < 0.0001) with little significant contribution of KCO, %predicted and FEV1, %predicted to the total model (total R2 = 0.626, p < 0.0001). Similar associations were obtained when using CT-automated density scores for emphysema assessment. Receiver operating characteristic (ROC) curves pointed to 131° as the best cut-off for emphysema (95.5% positive predictive value, 97% specificity and 51% sensitivity). Validation in a second group confirmed the significant difference in mean AC between emphysema and non-emphysema subjects. When applying the 131° cut-off, a positive predictive value of 95.6%, a specificity of 96% and a sensitivity of 59% were demonstrated. CONCLUSIONS: Airway collapse on forced expiration quantified by a computer model correlates with emphysema. An AC below 131° can be considered as a specific cut-off for predicting the presence of emphysema in heavy smokers.


Assuntos
Simulação por Computador , Enfisema/diagnóstico , Enfisema/fisiopatologia , Volume Expiratório Forçado/fisiologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Tomografia Computadorizada por Raios X , Idoso , Algoritmos , Estudos de Coortes , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fumar , Espirometria
4.
J Magn Reson Imaging ; 37(6): 1392-401, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23172614

RESUMO

PURPOSE: To prospectively evaluate multiparametric magnetic resonance imaging (MRI) for accurate localization of intraprostatic tumor nodules, with whole-mount histopathology as the gold standard. MATERIALS AND METHODS: Seventy-five patients with biopsy-proven, intermediate, and high-risk prostate cancer underwent preoperative T2-weighted (T2w), dynamic contrast-enhanced (DCE) and diffusion-weighted (DW) MRI at 1.5T. Localization of suspicious lesions was recorded for each of 24 standardized regions of interest on the different MR images and correlated with the pathologic findings. Generalized estimating equations (GEE) were used to estimate the sensitivity, specificity, accuracy, positive, and negative predictive value for every MRI modality, as well as to evaluate the influence of Gleason score and pT-stage. Tumor volume measurements on histopathological specimens were correlated with those on the different MR modalities (Pearson correlation). RESULTS: DW MRI had the highest sensitivity for tumor localization (31.1% vs. 27.4% vs. 44.5% for T2w, DCE, and DW MRI, respectively; P < 0.005), with more aggressive or more advanced tumors being more easily detected with this imaging modality. Significantly higher sensitivity values were obtained for the combination of T2w, DCE, and DW MRI (58.8%) as compared to each modality alone or any combination of two modalities (P < 0.0001). Tumor volume can most accurately be assessed by means of DW MRI (r = 0.75; P < 0.0001). CONCLUSION: Combining T2w, DCE, and DW imaging significantly improves prostate cancer localization.


Assuntos
Algoritmos , Biópsia por Agulha/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia , Idoso , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Prognóstico , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
5.
Med Phys ; 37(4): 1554-64, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443476

RESUMO

PURPOSE: A robust and accurate method that allows the automatic detection of fiducial markers in MV and kV projection image pairs is proposed. The method allows to automatically correct for inter or intrafraction motion. METHODS: Intratreatment MV projection images are acquired during each of five treatment beams of prostate cancer patients with four implanted fiducial markers. The projection images are first preprocessed using a series of marker enhancing filters. 2D candidate marker locations are generated for each of the filtered projection images and 3D candidate marker locations are reconstructed by pairing candidates in subsequent projection images. The correct marker positions are retrieved in 3D by the minimization of a cost function that combines 2D image intensity and 3D geometric or shape information for the entire marker configuration simultaneously. This optimization problem is solved using dynamic programming such that the globally optimal configuration for all markers is always found. Translational interfraction and intrafraction prostate motion and the required patient repositioning is assessed from the position of the centroid of the detected markers in different MV image pairs. The method was validated on a phantom using CT as ground-truth and on clinical data sets of 16 patients using manual marker annotations as ground-truth. RESULTS: The entire setup was confirmed to be accurate to around 1 mm by the phantom measurements. The reproducibility of the manual marker selection was less than 3.5 pixels in the MV images. In patient images, markers were correctly identified in at least 99% of the cases for anterior projection images and 96% of the cases for oblique projection images. The average marker detection accuracy was 1.4 +/- 1.8 pixels in the projection images. The centroid of all four reconstructed marker positions in 3D was positioned within 2 mm of the ground-truth position in 99.73% of all cases. Detecting four markers in a pair of MV images takes a little less than a second where most time is spent on the image preprocessing. CONCLUSIONS: The authors have developed a method to automatically detect multiple markers in a pair of projection images that is robust, accurate, and sufficiently fast for clinical use. It can be used for kV, MV, or mixed image pairs and can cope with limited motion between the projection images.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Algoritmos , Automação , Humanos , Imageamento Tridimensional/métodos , Masculino , Modelos Estatísticos , Aceleradores de Partículas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes
6.
Radiother Oncol ; 90(3): 331-6, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19013658

RESUMO

BACKGROUND AND PURPOSE: Currently, most available patient alignment tools based on implanted markers use manual marker matching and rigid registration transformations to measure the needed translational shifts. To quantify the particular effect of prostate gland shrinkage, implanted gold markers were tracked during a course of radiotherapy including an isotropic scaling factor to model prostate shrinkage. MATERIALS AND METHODS: Eight patients with prostate cancer had gold markers implanted transrectally and seven were treated with (neo) adjuvant androgen deprivation therapy. After patient alignment to skin tattoos, orthogonal electronic portal images (EPIs) were taken. A semi-automated 2D/3D marker-based registration was performed to calculate the necessary couch shifts. The registration consists of a rigid transformation combined with an isotropic scaling to model prostate shrinkage. RESULTS: The inclusion of an isotropic shrinkage model in the registration algorithm cancelled the corresponding increase in registration error. The mean scaling factor was 0.89+/-0.09. For all but two patients, a decrease of the isotropic scaling factor during treatment was observed. However, there was almost no difference in the translation offset between the manual matching of the EPIs to the digitally reconstructed radiographs and the semi-automated 2D/3D registration. A decrease in the intermarker distance was found correlating with prostate shrinkage rather than with random marker migration. CONCLUSIONS: Inclusion of shrinkage in the registration process reduces registration errors during a course of radiotherapy. Nevertheless, this did not lead to a clinically significant change in the proposed table translations when compared to translations obtained with manual marker matching without a scaling correction.


Assuntos
Adenocarcinoma/radioterapia , Próstata/patologia , Neoplasias da Próstata/radioterapia , Adenocarcinoma/tratamento farmacológico , Algoritmos , Antagonistas de Androgênios/uso terapêutico , Terapia Combinada , Ouro , Humanos , Imageamento Tridimensional , Masculino , Modelos Teóricos , Próstata/efeitos da radiação , Neoplasias da Próstata/tratamento farmacológico
7.
Acta Oncol ; 47(7): 1237-48, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18654902

RESUMO

PURPOSE: The purpose of this study is to investigate the use of PET/CT with fluorodeoxyglucose (FDG), fluorothymidine (FLT) and fluoromisonidazole (FMISO) for radiotherapy (RT) target definition and evolution in rectal cancer. MATERIALS AND METHODS: PET/CT was performed before and during preoperative chemoradiotherapy (CRT) in 15 patients with resectable rectal cancer. PET signals were delineated and CT images on the different time points were non-rigidly registered. Mismatch analyses were carried out to quantify the overlap between FDG and FLT or FMISO tumour volumes (TV) and between PET TVs over time. RESULTS: Ninety sequential PET/CT images were analyzed. The mean FDG, FLT and FMISO-PET TVs showed a tendency to shrink during preoperative CRT. On each time point, the mean FDG-PET TV was significantly larger than the FMISO-PET TV but not significantly larger than the mean FLT-PET TV. There was a mean 65% mismatch between the FMISO and FDG TVs obtained before and during CRT. FLT TVs corresponded better with the FDG TVs (25% mismatch before and 56% during CRT). During CRT, on average 61% of the mean FDG TV (7 cc) overlapped with the baseline mean TV (15.5 cc) (n=15). For FLT, the TV overlap was 49% (n=5) and for FMISO only 20% of the TV during CRT remained inside the contour at baseline (n=10). CONCLUSION: FDG, FLT and FMISO-PET reflect different functional characteristics that change during CRT in rectal cancer. FLT and FDG show good spatial correspondence, while FMISO seems less reliable due to the non-specific FMISO uptake in normoxic tissue and tracer diffusion through the bowel wall. FDG and FLT-PET/CT imaging seem most appropriate to integrate in preoperative RT for rectal cancer.


Assuntos
Didesoxinucleosídeos , Fluordesoxiglucose F18 , Misonidazol/análogos & derivados , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Neoplasias Retais/diagnóstico , Neoplasias Retais/radioterapia , Tomografia Computadorizada por Raios X , Antimetabólitos Antineoplásicos/uso terapêutico , Hipóxia Celular , Terapia Combinada , Fluoruracila/uso terapêutico , Humanos , Carga Tumoral
8.
J Biomech ; 49(9): 1411-1419, 2016 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-27113537

RESUMO

Achilles tendinopathy remains one of the most prevalent overuse injuries in elite as well as recreational athletes. Regardless of the fact that the aetiology of tendinopathy has not been fully understood, therapeutic mechanical loading programs have emerged as being the treatment of choice. In this light, mechanical properties of the tendon and their response to changes in loading or unloading have been the subject of many previous investigations. One of these properties often investigated is strain, a measure of relative deformation. By means of a systematic review, an overview was given of research in this field, with a primary objective to list the methods used and secondary aim to synthesize data on strain mapping in the Achilles tendon. Following the guidelines of the PRISMA statement, 47 articles were found appropriate for qualitative assessment. Achilles tendon strain has been investigated across a variety of contexts, including the response to exercise, walking, unloading, ageing, hormonal changes and weight. Only three studies investigated the effect of the presence of tendinopathy on strain. Ultrasound was the most often used imaging modality to measure or estimate strain. Further methodological parameters, e.g. the location of measurement, differed greatly between all different studies. Nearly all studies considered global strain. Some studies investigated the transverse strain response of the Achilles tendon. Recently, however, the role of local - intratendinous - strain distribution has been found to be of critical importance and further studies should focus on imaging modalities to investigate these local changes.


Assuntos
Tendão do Calcâneo , Estresse Mecânico , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/fisiologia , Tendão do Calcâneo/fisiopatologia , Diagnóstico por Imagem , Humanos , Tendinopatia/diagnóstico por imagem , Tendinopatia/fisiopatologia , Suporte de Carga
9.
Eur J Oral Implantol ; 9(4): 411-424, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27990508

RESUMO

PURPOSE: To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement. MATERIALS AND METHODS: Eight edentulous human mandibular bone samples were scanned with seven CBCT scanners (3D Accuitomo 170, i-CAT Next Generation, ProMax 3D Max, Scanora 3D, Cranex 3D, Newtom GiANO and Carestream 9300) and one MSCT system (Somatom Definition Flash) using the clinical exposure protocol with the highest resolution. Micro-CT (SkyScan 1174) images served as a gold standard. A volume of interest (VOI) comprising trabecular and cortical bone only was delineated on the micro-CT. After spatial alignment of all scan types, micro-CT VOIs were overlaid on the CBCT and MSCT images. Segmentation was applied and morphometric parameters were calculated for each scanner. CBCT and MSCT morphometric parameters were compared with micro-CT using mixed-effect models. Intraclass correlation analysis was used to grade the accuracy of each scanner in assessing trabecular and cortical quality in comparison with the gold standard. Bone structure patterns of each scanner were compared with micro-CT in 2D and 3D to facilitate the interpretation of the morphometric analysis. RESULTS: Morphometric analysis showed an overestimation of the cortical and trabecular bone quantity during CBCT and MSCT evaluation compared to the gold standard micro-CT. The trabecular thickness (Tb.Th) was found to be significantly (P < 0.05) different and the smallest overestimation was found for the ProMax 3D Max (180 µm), followed by the 3D Accuitomo 170 (200 µm), Carestream 9300 (220 µm), Newtom GiANO (240 µm), Cranex 3D (280 µm), Scanora 3D (300 µm), high resolution MSCT (310 µm), i-CAT Next Generation (430 µm) and standard resolution MSCT (510 µm). The underestimation of the cortical thickness (Ct.Th) in ProMax 3D Max (-10 µm), the overestimation in Newtom GiANO (10 µm) and the high resolution MSCT (10 µm) were neglible. However, a significant overestimation (P < 0.05) was found for 3D Accuitomo 170 (110 µm), Scanora 3D (140 µm), standard resolution MSCT (150 µm), Carestream 9300 (190 µm), Cranex 3D (190 µm) and i-CAT Next Generation (230 µm). Comparison of the 2D network and 3D surface distance confirmed the overestimation in bone quantity, but only demonstrated a deviant trabecular network for the i-CAT Next Generation and the standard resolution MSCT. Intraclass correlation coefficients (ICCs) showed a significant (P < 0.05) high intra-observer reliability (ICC > 0.70) in morphometric evaluation between micro-CT and commercially available CBCT scanners (3D Accuitomo 170, Newtom GiANO and ProMax 3D Max). The ICC for Tb.Th and Ct.Th were 0.72 and 0.98 (3D Accuitomo 170), 0.71 and 0.96 (Newtom GiANO), and 0.87 and 0.92 (ProMax 3D Max), respectively. CONCLUSIONS: High resolution CBCT offers a clinical alternative to MSCT to objectively determine the bone quality prior to implant placement. However, not all tested CBCT machines have sufficient resolution to accurately depict the trabecular network or cortical bone. Conflict-of-interest statement: There is no conflict of interest to declare. FUNDING: Fellowship support came from Research Foundation Flanders (FWO) from the Belgian government, and Coordination for the Improvement of Higher Education Personnel (CAPES) program and Science without borders from the Brazilian government.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Arcada Edêntula/diagnóstico por imagem , Microtomografia por Raio-X , Tomografia Computadorizada de Feixe Cônico/instrumentação , Humanos , Mandíbula/anatomia & histologia , Mandíbula/diagnóstico por imagem
10.
Radiother Oncol ; 117(1): 29-35, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26255763

RESUMO

BACKGROUND AND PURPOSE: There is a huge difference in radiosensitivity of lungs between patients. The present study aims to identify and quantify patient-specific radiosensitivity based on a single pre-treatment CT scan. MATERIALS AND METHODS: 130 lung cancer patients were studied: 60 stereotactic ablative radiotherapy (SABR) treatments and 70 conventional treatments (20 and 30 patients from external datasets, respectively). A 3month-follow-up scan (CT3M) was non-rigidly registered to the planning CT scan (CT0). Changes in Hounsfield Units (ΔHU=HU3M-HU0) inside lung subvolumes were analyzed per dose bin of 5Gy. ΔHU was modeled as a function of local dose using linear and sigmoidal fits. Sigmoidal fit parameters ΔHUmax (saturation level) and D50 (dose corresponding to 50% of ΔHUmax) were collected for all patients. RESULTS: Sigmoidal fits outperformed linear fits in the SABR groups for the majority of patients. Sigmoidal dose-responses were also observed in both conventional groups but to a lesser extent. Distributions of D50 and ΔHUmax showed a large variation between patients in all datasets. Higher baseline lung density (p<0.001) was prognostic for higher ΔHUmax in one SABR group. No prognostic factors were found for D50. CONCLUSIONS: Baseline CT characteristics are prognostic for radiation-induced lung damage susceptibility.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Lesões por Radiação/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Modelos Estatísticos , Prognóstico , Lesões por Radiação/etiologia , Tolerância a Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
11.
Clin Implant Dent Relat Res ; 17 Suppl 2: e745-50, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25873135

RESUMO

BACKGROUND: Little attention has been paid to the effect of implant restorations on speech. PURPOSE: The aim of this study was threefold: (1) to find out if speech problems occur after inserting a fixed provisional restoration in the edentulous maxilla; (2) to explore speech adaptation in case articulation problems arise after rehabilitation; and (3) to describe the effect of changing the shape of the restoration on improving speech. MATERIALS AND METHODS: Ten patients with an edentulous maxilla were treated with fixed rehabilitation on implants. Speech evaluation was performed at four occasions: before implant surgery, immediately after restoration, and 3 weeks later before and after managing the speech problem by changing the shape of the restoration if speech problems occurred. Comparative three-dimensional-analysis of casts of the restoration before and after changing the shape of the restoration was carried out. RESULTS: The majority of patients (n = 7) experienced speech problems immediately after rehabilitation. Three weeks later, none of the seven patients with deteriorated speech returned to baseline speech. Then, volumetric reduction of the palatal aspects of the (pre)molars was performed, which allowed speech to return to baseline levels in five out of seven patients. In the two remaining patients, the intervention resulted in an improvement of speech without reaching their baseline levels. Three-dimensional-analysis showed that reducing the palatal volume of the premolars was effective in correcting speech. CONCLUSIONS: Speech problems may frequently occur after fixed rehabilitation of the completely edentulous maxilla. A novel speech management concept, consisting of reducing the palatal volume of the (pre)molars, is introduced, demonstrating to solve speech problems in most cases.


Assuntos
Transtornos da Articulação/etiologia , Implantação Dentária Endóssea/efeitos adversos , Implantes Dentários/efeitos adversos , Arcada Edêntula/cirurgia , Idoso , Idoso de 80 Anos ou mais , Audiologia , Reparação em Prótese Dentária , Restauração Dentária Permanente/efeitos adversos , Dentaduras/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
Artigo em Inglês | MEDLINE | ID: mdl-26736217

RESUMO

Speckle tracking echocardiography (STE) is now widely used for measuring strain, deformations, and motion in cardiology. STE involves three successive steps: acquisition of individual frames, speckle detection, and image registration using speckles as landmarks. This work proposes to avoid explicit detection and registration by representing dynamic ultrasound images as sparse collections of moving Gaussian elements in the continuous joint space-time space. Individual speckles or local clusters of speckles are approximated by a single multivariate Gaussian kernel with associated linear trajectory over a short time span. A hierarchical tree-structured model is fitted to sampled input data such that predicted image estimates can be retrieved by regression after reconstruction, allowing a (bias-variance) trade-off between model complexity and image resolution. The inverse image reconstruction problem is solved with an online Bayesian statistical estimation algorithm. Experiments on clinical data could estimate subtle sub-pixel accurate motion that is difficult to capture with frame-to-frame elastic image registration techniques.


Assuntos
Ecocardiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Animais , Teorema de Bayes , Movimento (Física) , Distribuição Normal , Ovinos , Tendões/diagnóstico por imagem
13.
Radiother Oncol ; 110(2): 329-34, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24231234

RESUMO

PURPOSE: In head and neck cancer, diffusion weighted MRI (DWI) can predict response early during treatment. Treatment-induced changes and DWI-specific artifacts hinder an accurate registration between apparent diffusion coefficient (ADC) maps. The aim of the study was to develop a registration tool which calculates and visualizes regional changes in ADC. METHODS: Twenty patients with stage IV HNC treated with primary radiotherapy received an MRI including DWI before and early during treatment. Markers were manually placed at anatomical landmarks on the different modalities at both time points. A registration method, consisting of a fully automatic rigid and nonrigid registration and two semi-automatic thin-plate spline (TPS) warps was developed and applied to the image sets. After each registration step the mean registration errors were calculated and ΔADC was compared between good and poor responders. RESULTS: Adding the TPS warps significantly reduced the registration error (in mm, 6.3 ± 6.2 vs 3.2 ± 3.3 mm, p<0.001). After the marker based registration the median ΔADC in poor responders was significantly lower than in good responders (7% vs. 21%; p<0.001). CONCLUSIONS: This registration method allowed for a significant reduction of the mean registration error. Furthermore the voxel-wise calculation of the ΔADC early during radiotherapy allowed for a visualization of the regional differences of ΔADC within the tumor.


Assuntos
Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/radioterapia , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Carcinoma de Células Escamosas de Cabeça e Pescoço , Tomografia Computadorizada por Raios X/métodos
14.
Med Phys ; 41(6): 061716, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24877811

RESUMO

PURPOSE: Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy have become standard treatments but are more sensitive to anatomical variations than 3D conformal techniques. To correct for inter- and intrafraction anatomical variations, fast and easy to implement methods are needed. Here, the authors propose a full dosimetric IMRT correction that finds a compromise in-between basic repositioning (the current clinical practice) and full replanning. It simplifies replanning by avoiding a recontouring step and a full dose calculation. It surpasses repositioning by updating the preoptimized fluence and monitor units (MU) using a limited number of fiducial points and a pretreatment (CB)CT. To adapt the fluence the fiducial points were projected in the beam's eye view (BEV). To adapt the MUs, point dose calculation towards the same fiducial points were performed. The proposed method is intrinsically fast and robust, and simple to understand for operators, because of the use of only four fiducial points and the beam data based point dose calculations. METHODS: To perform our dosimetric adaptation, two fluence corrections in the BEV are combined with two MU correction steps along the beam's path. (1) A transformation of the fluence map such that it is realigned with the current target geometry. (2) A correction for an unintended scaling of the penumbra margin when the treatment beams scale to the current target size. (3) A correction for the target depth relative to the body contour and (4) a correction for the target distance to the source. The impact of the correction strategy and its individual components was evaluated by simulations on a virtual prostate phantom. This heterogeneous reference phantom was systematically subjected to population based prostate transformations to simulate interfraction variations. Additionally, a patient example illustrated the clinical practice. The correction strategy was evaluated using both dosimetric (CTV mean dose, conformity index) and clinical (tumor control probability, and normal tissue complication probability) measures. RESULTS: Based on the current experiments, the intended target dose and tumor control probability could be assured by the proposed method (TCP ≥ TCP(intended)). Additionally, the conformity index error was more than halved compared to the current clinical practice (ΔCI(95%) from 40% to 16%) resulting in improved organ at risk protection. All the individual correction steps had an added value to the full correction. CONCLUSIONS: A limited number of fiducial points (no organ contours required) and an in-room (CB)CT are sufficient to perform a full dosimetric correction for IMRT plans. In the presence of interfraction variation, the corrected plans show superior dose distributions compared to our current clinical practice.


Assuntos
Marcadores Fiduciais , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Canal Anal/efeitos da radiação , Simulação por Computador , Fracionamento da Dose de Radiação , Humanos , Masculino , Modelos Biológicos , Movimento (Física) , Imagens de Fantasmas , Próstata , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Reto/efeitos da radiação , Rotação , Bexiga Urinária/efeitos da radiação
15.
Int J Radiat Oncol Biol Phys ; 85(5): 1172-8, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23149005

RESUMO

PURPOSE: Strain rate imaging (SRI) is a new echocardiographic modality that enables accurate measurement of regional myocardial function. We investigated the role of SRI and troponin I (TnI) in the detection of subclinical radiation therapy (RT)-induced cardiotoxicity in breast cancer patients. METHODS AND MATERIALS: This study prospectively included 75 women (51 left-sided and 24 right-sided) receiving adjuvant RT to the breast/chest wall and regional lymph nodes. Sequential echocardiographs with SRI were obtained before RT, immediately after RT, and 8 and 14 months after RT. TnI levels were measured on the first and last day of RT. RESULTS: Mean heart and left ventricle (LV) doses were both 9 ± 4 Gy for the left-sided patients and 4 ± 4 Gy and 1 ± 0.4 Gy, respectively, for the right-sided patients. A decrease in strain was observed at all post-RT time points for left-sided patients (-17.5% ± 1.9% immediately after RT, -16.6% ± 1.4% at 8 months, and -17.7% ± 1.9% at 14 months vs -19.4% ± 2.4% before RT, P<.01) but not for right-sided patients. When we considered left-sided patients only, the highest mean dose was given to the anterior left ventricular (LV) wall (25 ± 14 Gy) and the lowest to the inferior LV wall (3 ± 3 Gy). Strain of the anterior wall was reduced after RT (-16.6% ± 2.3% immediately after RT, -16% ± 2.6% at 8 months, and -16.8% ± 3% at 14 months vs -19% ± 3.5% before RT, P<.05), whereas strain of the inferior wall showed no significant change. No changes were observed with conventional echocardiography. Furthermore, mean TnI levels for the left-sided patients were significantly elevated after RT compared with before RT, whereas TnI levels of the right-sided patients remained unaffected. CONCLUSIONS: In contrast to conventional echocardiography, SRI detected a regional, subclinical decline in cardiac function up to 14 months after breast RT. It remains to be determined whether these changes are related to clinical outcome. In the meantime, we encourage the use of radiation techniques that minimize the exposure of the anterior LV wall in left-sided patients.


Assuntos
Neoplasias da Mama/radioterapia , Ecocardiografia/métodos , Coração/efeitos da radiação , Neoplasias da Mama/patologia , Feminino , Coração/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/efeitos da radiação , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Fatores de Tempo , Troponina I/sangue
16.
J Endod ; 39(9): 1111-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23953281

RESUMO

INTRODUCTION: The routine use of high-resolution images derived from 3-dimensional cone-beam computed tomography (CBCT) datasets enables the linear measurement of lesions in the maxillary and mandibular bones on 3 planes of space. Measurements on different planes would make it possible to obtain real volumetric assessments. In this study, we tested, in vitro, the accuracy and reliability of new dedicated software developed for volumetric lesion assessment in clinical endodontics. METHODS: Twenty-seven bone defects were created around the apices of 8 teeth in 1 young bovine mandible to simulate periapical lesions of different sizes and shapes. The volume of each defect was determined by taking an impression of the defect using a silicone material. The samples were scanned using an Accuitomo 170 CBCT (J. Morita Mfg Co, Kyoto, Japan), and the data were uploaded into a newly developed dedicated software tool. Two endodontists acted as independent and calibrated observers. They analyzed each bone defect for volume. The difference between the direct volumetric measurements and the measurements obtained with the CBCT images was statistically assessed using a lack-of-fit test. A correlation study was undertaken using the Pearson product-moment correlation coefficient. Intra- and interobserver agreement was also evaluated. RESULTS: The results showed a good fit and strong correlation between both volume measurements (ρ > 0.9) with excellent inter- and intraobserver agreement. CONCLUSIONS: Using this software, CBCT proved to be a reliable method in vitro for the estimation of endodontic lesion volumes in bovine jaws. Therefore, it may constitute a new, validated technique for the accurate evaluation and follow-up of apical periodontitis.


Assuntos
Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Doenças Mandibulares/diagnóstico por imagem , Periodontite Periapical/diagnóstico por imagem , Animais , Dente Pré-Molar/diagnóstico por imagem , Bovinos , Materiais para Moldagem Odontológica/química , Imageamento Tridimensional/estatística & dados numéricos , Dente Molar/diagnóstico por imagem , Variações Dependentes do Observador , Tamanho do Órgão , Polivinil/química , Reprodutibilidade dos Testes , Siloxanas/química , Software , Propriedades de Superfície , Ápice Dentário/diagnóstico por imagem
17.
Radiother Oncol ; 98(2): 181-6, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21295871

RESUMO

INTRODUCTION: Intrafractional motion consists of two components: (1) the movement between the on-line repositioning procedure and the treatment start and (2) the movement during the treatment delivery. The goal of this study is to estimate this intrafractional movement of the prostate during prostate cancer radiotherapy. MATERIAL AND METHODS: Twenty-seven patients with prostate cancer and implanted fiducials underwent a marker match procedure before a five-field IMRT treatment. For all fields, in-treatment images were obtained and then processed to enable automatic marker detection. Combining the subsequent projection images, five positions of each marker were determined using the shortest path approach. The residual set-up error (RSE) after kV-MV based prostate localization, the prostate position as a function of time during a radiotherapy session and the required margins to account for intrafractional motion were determined. RESULTS: The mean RSE and standard deviation in the antero-posterior, cranio-caudal and left-right direction were 2.3±1.5 mm, 0.2±1.1 mm and -0.1±1.1 mm, respectively. Almost all motions occurred in the posterior direction before the first treatment beam as the percentage of excursions>5 mm was reduced significantly when the RSE was not accounted for. The required margins for intrafractional motion increased with prolongation of the treatment. Application of a repositioning protocol after every beam could decrease the 1cm margin from CTV to PTV by 2 mm. CONCLUSIONS: The RSE is the main contributor to intrafractional motion. This RSE after on-line prostate localization and patient repositioning in the posterior direction emphasizes the need to speed up the marker match procedure. Also, a prostate IMRT treatment should be administered as fast as possible, to ensure that the pre-treatment repositioning efforts are not erased by intrafractional prostate motion. This warrants an optimized workflow with the use of faster treatment techniques.


Assuntos
Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Movimento (Física) , Posicionamento do Paciente
18.
Radiother Oncol ; 98(1): 126-33, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21176986

RESUMO

PURPOSE: To develop and validate an accurate predictive model and a nomogram for pathologic complete response (pCR) after chemoradiotherapy (CRT) for rectal cancer based on clinical and sequential PET-CT data. Accurate prediction could enable more individualised surgical approaches, including less extensive resection or even a wait-and-see policy. METHODS AND MATERIALS: Population based databases from 953 patients were collected from four different institutes and divided into three groups: clinical factors (training: 677 patients, validation: 85 patients), pre-CRT PET-CT (training: 114 patients, validation: 37 patients) and post-CRT PET-CT (training: 107 patients, validation: 55 patients). A pCR was defined as ypT0N0 reported by pathology after surgery. The data were analysed using a linear multivariate classification model (support vector machine), and the model's performance was evaluated using the area under the curve (AUC) of the receiver operating characteristic (ROC) curve. RESULTS: The occurrence rate of pCR in the datasets was between 15% and 31%. The model based on clinical variables (AUC(train)=0.61±0.03, AUC(validation)=0.69±0.08) resulted in the following predictors: cT- and cN-stage and tumour length. Addition of pre-CRT PET data did not result in a significantly higher performance (AUC(train)=0.68±0.08, AUC(validation)=0.68±0.10) and revealed maximal radioactive isotope uptake (SUV(max)) and tumour location as extra predictors. The best model achieved was based on the addition of post-CRT PET-data (AUC(train)=0.83±0.05, AUC(validation)=0.86±0.05) and included the following predictors: tumour length, post-CRT SUV(max) and relative change of SUV(max). This model performed significantly better than the clinical model (p(train)<0.001, p(validation)=0.056). CONCLUSIONS: The model and the nomogram developed based on clinical and sequential PET-CT data can accurately predict pCR, and can be used as a decision support tool for surgery after prospective validation.


Assuntos
Tomografia por Emissão de Pósitrons , Neoplasias Retais/patologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/diagnóstico por imagem
19.
IEEE Trans Med Imaging ; 29(1): 19-29, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19447700

RESUMO

Maximization of mutual information (MMI) is a popular similarity measure for medical image registration. Although its accuracy and robustness has been demonstrated for rigid body image registration, extending MMI to nonrigid image registration is not trivial and an active field of research. We propose conditional mutual information (cMI) as a new similarity measure for nonrigid image registration. cMI starts from a 3-D joint histogram incorporating, besides the intensity dimensions, also a spatial dimension expressing the location of the joint intensity pair. cMI is calculated as the expected value of the cMI between the image intensities given the spatial distribution. The cMI measure was incorporated in a tensor-product B-spline nonrigid registration method, using either a Parzen window or generalized partial volume kernel for histogram construction. cMI was compared to the classical global mutual information (gMI) approach in theoretical, phantom, and clinical settings. We show that cMI significantly outperforms gMI for all applications.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Teoria da Informação , Algoritmos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
20.
Int J Radiat Oncol Biol Phys ; 75(3): 782-90, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19289265

RESUMO

PURPOSE: To investigate the feasibility of integrating multiple imaging modalities for image-guided radiotherapy in rectal cancer. PATIENTS AND METHODS: Magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) were performed before, during, and after preoperative chemoradiotherapy (CRT) in patients with resectable rectal cancer. The FDG-PET signals were segmented with an adaptive threshold-based and a gradient-based method. Magnetic resonance tumor volumes (TVs) were manually delineated. A nonrigid registration algorithm was applied to register the images, and mismatch analyses were carried out between MR and FDG-PET TVs and between TVs over time. Tumor volumes delineated on the images after CRT were compared with the pathologic TV. RESULTS: Forty-five FDG-PET/CT and 45 MR images were analyzed from 15 patients. The mean MRI and FDG-PET TVs showed a tendency to shrink during and after CRT. In general, MRI showed larger TVs than FDG-PET. There was an approximately 50% mismatch between the FDG-PET TV and the MRI TV at baseline and during CRT. Sixty-one percent of the FDG-PET TV and 76% of the MRI TV obtained after 10 fractions of CRT remained inside the corresponding baseline TV. On MRI, residual tumor was still suspected in all 6 patients with a pathologic complete response, whereas FDG-PET showed a metabolic complete response in 3 of them. The FDG-PET TVs delineated with the gradient-based method matched closest with pathologic findings. CONCLUSIONS: Integration of MRI and FDG-PET into radiotherapy seems feasible. Gradient-based segmentation is recommended for FDG-PET. Spatial variance between MRI and FDG-PET TVs should be taken into account for target definition.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Retais/radioterapia , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Antimetabólitos Antineoplásicos/uso terapêutico , Terapia Combinada/métodos , Estudos de Viabilidade , Feminino , Fluordesoxiglucose F18 , Fluoruracila/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Dosagem Radioterapêutica , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/tratamento farmacológico , Neoplasias Retais/patologia , Indução de Remissão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA