Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 121(12): e2318716121, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38483991

RESUMO

Deep convection in the Asian summer monsoon is a significant transport process for lifting pollutants from the planetary boundary layer to the tropopause level. This process enables efficient injection into the stratosphere of reactive species such as chlorinated very-short-lived substances (Cl-VSLSs) that deplete ozone. Past studies of convective transport associated with the Asian summer monsoon have focused mostly on the south Asian summer monsoon. Airborne observations reported in this work identify the East Asian summer monsoon convection as an effective transport pathway that carried record-breaking levels of ozone-depleting Cl-VSLSs (mean organic chlorine from these VSLSs ~500 ppt) to the base of the stratosphere. These unique observations show total organic chlorine from VSLSs in the lower stratosphere over the Asian monsoon tropopause to be more than twice that previously reported over the tropical tropopause. Considering the recently observed increase in Cl-VSLS emissions and the ongoing strengthening of the East Asian summer monsoon under global warming, our results highlight that a reevaluation of the contribution of Cl-VSLS injection via the Asian monsoon to the total stratospheric chlorine budget is warranted.

2.
Am Heart J ; 185: 67-73, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28267477

RESUMO

BACKGROUND: To compare simultaneous recordings from an external patch system specifically designed to ensure better P-wave recordings and standard Holter monitor to determine diagnostic efficacy. Holter monitors are a mainstay of clinical practice, but are cumbersome to access and wear and P-wave signal quality is frequently inadequate. METHODS: This study compared the diagnostic efficacy of the P-wave centric electrocardiogram (ECG) patch (Carnation Ambulatory Monitor) to standard 3-channel (leads V1, II, and V5) Holter monitor (Northeast Monitoring, Maynard, MA). Patients were referred to a hospital Holter clinic for standard clinical indications. Each patient wore both devices simultaneously and served as their own control. Holter and Patch reports were read in a blinded fashion by experienced electrophysiologists unaware of the findings in the other corresponding ECG recording. All patients, technicians, and physicians completed a questionnaire on comfort and ease of use, and potential complications. RESULTS: In all 50 patients, the P-wave centric patch recording system identified rhythms in 23 patients (46%) that altered management, compared to 6 Holter patients (12%), P<.001. The patch ECG intervals PR, QRS and QT correlated well with the Holter ECG intervals having correlation coefficients of 0.93, 0.86, and 0.94, respectively. Finally, 48 patients (96%) preferred wearing the patch monitor. CONCLUSIONS: A single-channel ambulatory patch ECG monitor, designed specifically to ensure that the P-wave component of the ECG be visible, resulted in a significantly improved rhythm diagnosis and avoided inaccurate diagnoses made by the standard 3-channel Holter monitor.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Síncope/diagnóstico , Adulto , Idoso , Arritmias Cardíacas/complicações , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Preferência do Paciente , Estudos Prospectivos , Síncope/etiologia
3.
Heart Lung Circ ; 25(3): 275-81, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26546095

RESUMO

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is associated with a high incidence of ventricular tachyarrhythmia and sudden death. The mainstay of management is the implantable cardioverter defibrillator (ICD). A small number of patient cohorts have generated a large number of reports. METHODS: Prospective registry data supplemented with clinical and ICD records of 30 patients with ARVC fulfilling the 2010 modified Task Force Criteria. This cohort has not been reported on previously. RESULTS: Median age at diagnosis: 46yrs (range 21-68); 20 (80%) male; six (19%) Maori. Duration of follow-up: 7.4yrs (range 1.7-23). Implantable cardioverter defibrillator implantation in 26; three (12%) for resuscitated sudden cardiac death; 17 (65%) for symptomatic ventricular tachyarrhythmia; three (12%) for syncope; and three (12%) for family history of sudden death attributable to ARVC. Two patients died during follow-up, one had an ICD, though died of a carcinoma. Thirteen (50%) experienced appropriate ICD therapy with median time to therapy 12 months, and four (15%) experienced inappropriate shock therapy. Male gender was an independent predictor of appropriate ICD therapy (HR 1.6, 95% CI 1.5-2.7, P=0.01). CONCLUSIONS: The long-term prognosis of patients with ARVC is favourable although high proportions receive appropriate ICD therapy. Male gender is an independent predictor of appropriate ICD therapy.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Efeitos Psicossociais da Doença , Hipertrofia Ventricular Direita/diagnóstico , Hipertrofia Ventricular Direita/terapia , Sistema de Registros , Adulto , Idoso , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Feminino , Seguimentos , Humanos , Hipertrofia Ventricular Direita/mortalidade , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores Sexuais
5.
J Cardiovasc Electrophysiol ; 26(12): 1346-51, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26332198

RESUMO

INTRODUCTION: The accurate prediction of the risk of sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) remains elusive. Corrected QT interval (QTc) duration is a known risk factor in various cardiac conditions. Single nucleotide polymorphisms (SNPs) have been linked to QTc length, and to SCD. Here we investigated the role of 21 candidate SNPs in QTc duration and SCD events in patients with HCM. METHODS AND RESULTS: This HCM registry-based study included patients with an ECG, medical history, first SCD event data, and DNA available. Each individual SNP was assessed using logistic regression for associations with 2 outcomes: a prolonged QTc ( ≥440 milliseconds), and first SCD event (SCD, resuscitated cardiac arrest, and appropriate implantable cardioverter defibrillator (ICD) shock for ventricular fibrillation/ventricular tachycardia (VF/VT). In 272 HCM patients, there were 31 SCD events (8 SCD, 9 resuscitated cardiac arrest, 14 ICD shocks for VF/VT; 11%). A QTc ≥ 500 milliseconds was associated with SCD events on multivariate analysis (odds ratio [OR] = 4.0, 95% confidence interval [CI], 1.19-12.02, P = 0.016). In 228 Caucasian patients, 2 SNPs in the NOS1AP gene (rs10494366 and rs12143842) were associated with a prolonged QTc after correction for multiple testing. This remained significant after adjustment for current age, sex, and ≥1 SCD risk factor (OR 1.59 per copy of the minor allele, 95% CI 1.08-2.39, P = 0.022, and OR 1.63, 95% CI 1.09-2.49, P = 0.020, respectively). No SNPs were directly associated with SCD events. CONCLUSION: SNPs in the NOS1AP gene influence QTc interval duration but we have not demonstrated a direct association with the risk of SCD.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/genética , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/fisiopatologia , Parada Cardíaca/etiologia , Parada Cardíaca/genética , Síndrome do QT Longo/genética , Síndrome do QT Longo/fisiopatologia , Idoso , Cardiomiopatia Hipertrófica/epidemiologia , Estudos de Coortes , DNA/genética , Morte Súbita Cardíaca , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Parada Cardíaca/epidemiologia , Humanos , Síndrome do QT Longo/epidemiologia , Masculino , Pessoa de Meia-Idade , Nova Zelândia/epidemiologia , Polimorfismo de Nucleotídeo Único , Risco , Resultado do Tratamento
6.
Circulation ; 128(9): 944-53, 2013 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-23979626

RESUMO

BACKGROUND: The most frequent complications associated with implantable cardioverter-defibrillators (ICDs) involve the transvenous leads. A subcutaneous implantable cardioverter-defibrillator (S-ICD) has been developed as an alternative system. This study evaluated the safety and effectiveness of the S-ICD System (Cameron Health/Boston Scientific) for the treatment of life-threatening ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation). METHODS AND RESULTS: This prospective, nonrandomized, multicenter trial included adult patients with a standard indication for an ICD, who neither required pacing nor had documented pace-terminable ventricular tachycardia. The primary safety end point was the 180-day S-ICD System complication-free rate compared with a prespecified performance goal of 79%. The primary effectiveness end point was the induced ventricular fibrillation conversion rate compared with a prespecified performance goal of 88%, with success defined as 2 consecutive ventricular fibrillation conversions of 4 attempts. Detection and conversion of spontaneous episodes were also evaluated. Device implantation was attempted in 321 of 330 enrolled patients, and 314 patients underwent successful implantation. The cohort was followed for a mean duration of 11 months. The study population was 74% male with a mean age of 52±16 years and mean left ventricular ejection fraction of 36±16%. A previous transvenous ICD had been implanted in 13%. Both primary end points were met: The 180-day system complication-free rate was 99%, and sensitivity analysis of the acute ventricular fibrillation conversion rate was >90% in the entire cohort. There were 38 discrete spontaneous episodes of ventricular tachycardia/ventricular fibrillation recorded in 21 patients (6.7%), all of which successfully converted. Forty-one patients (13.1%) received an inappropriate shock. CONCLUSIONS: The findings support the efficacy and safety of the S-ICD System for the treatment of life-threatening ventricular arrhythmias.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Adulto , Idoso , Estudos de Coortes , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
7.
N Engl J Med ; 363(1): 36-44, 2010 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20463331

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS: The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS: In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)


Assuntos
Desfibriladores Implantáveis , Cardiopatias/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Eletrodos Implantados , Desenho de Equipamento , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico , Adulto Jovem
8.
Ultrason Sonochem ; 100: 106625, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37801993

RESUMO

Ultrasonic dental scalers are indispensable instruments for efficient dental cleaning through the generation of cavitation. To gain valuable insights and enhance the cavitation cleaning effects, a numerical investigation is conducted using the finite element method via ABAQUS. Numerical results are compared with the experimental cavitation image for a scaler undergoes vibrations near a wall. We then analyse how the amplitude, frequency, and cross-sectional shape of the scaler affect cavitation generation. Numerical results indicate that cavitation is more pronounced for a scaler oscillating near a nearly rigid boundary than a soft boundary. It increases with the vibration amplitude because of higher ultrasonic energy transferring to the liquid and generating stronger pressure waves. The resonant frequency of the scaler coincides with the maximum cavitation and scaler tip amplitude. Reducing the dimension of the cross-section of the scaler in its oscillation direction increases both the scaler tip amplitude and the cavitation generated. This finding offers a potential design approach for enhancing the scaler cavitation and its cleaning effects. These insights provide practical guidance for optimising dental scaler settings, which can improve oral hygiene and prevent complications related to dental implants.


Assuntos
Terapia por Ultrassom , Ultrassom , Humanos , Bolsa Periodontal , Ultrassom/métodos , Vibração , Transferência de Energia
9.
Cells ; 12(21)2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37947603

RESUMO

Cannabis is now one of the most commonly used illicit substances among pregnant women. This is particularly concerning since developmental exposure to cannabinoids can elicit enduring neurofunctional and cognitive alterations. This study investigates the mechanisms of learning and memory deficits resulting from prenatal cannabinoid exposure (PCE) in adolescent offspring. The synthetic cannabinoid agonist WIN55,212-2 was administered to pregnant rats, and a series of behavioral, electrophysiological, and immunochemical studies were performed to identify potential mechanisms of memory deficits in the adolescent offspring. Hippocampal-dependent memory deficits in adolescent PCE animals were associated with decreased long-term potentiation (LTP) and enhanced long-term depression (LTD) at hippocampal Schaffer collateral-CA1 synapses, as well as an imbalance between GluN2A- and GluN2B-mediated signaling. Moreover, PCE reduced gene and protein expression of neural cell adhesion molecule (NCAM) and polysialylated-NCAM (PSA-NCAM), which are critical for GluN2A and GluN2B signaling balance. Administration of exogenous PSA abrogated the LTP deficits observed in PCE animals, suggesting PSA mediated alterations in GluN2A- and GluN2B- signaling pathways may be responsible for the impaired hippocampal synaptic plasticity resulting from PCE. These findings enhance our current understanding of how PCE affects memory and how this process can be manipulated for future therapeutic purposes.


Assuntos
Canabinoides , Moléculas de Adesão de Célula Nervosa , Humanos , Ratos , Feminino , Animais , Gravidez , Adolescente , Moléculas de Adesão de Célula Nervosa/metabolismo , Canabinoides/farmacologia , Canabinoides/metabolismo , Plasticidade Neuronal/fisiologia , Hipocampo/metabolismo , Transtornos da Memória/metabolismo
10.
Ann Surg ; 255(1): 30-7, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21637099

RESUMO

OBJECTIVE: We hypothesized that novices will perform better in the operating room after simulator training to automaticity compared with traditional proficiency based training (current standard training paradigm). BACKGROUND: Simulator-acquired skill translates to the operating room, but the skill transfer is incomplete. Secondary task metrics reflect the ability of trainees to multitask (automaticity) and may improve performance assessment on simulators and skill transfer by indicating when learning is complete. METHODS: Novices (N = 30) were enrolled in an IRB-approved, blinded, randomized, controlled trial. Participants were randomized into an intervention (n = 20) and a control (n = 10) group. The intervention group practiced on the FLS suturing task until they achieved expert levels of time and errors (proficiency), were tested on a live porcine fundoplication model, continued simulator training until they achieved expert levels on a visual spatial secondary task (automaticity) and were retested on the operating room (OR) model. The control group participated only during testing sessions. Performance scores were compared within and between groups during testing sessions. RESULTS: : Intervention group participants achieved proficiency after 54 ± 14 and automaticity after additional 109 ± 57 repetitions. Participants achieved better scores in the OR after automaticity training [345 (range, 0-537)] compared with after proficiency-based training [220 (range, 0-452; P < 0.001]. CONCLUSIONS: Simulator training to automaticity takes more time but is superior to proficiency-based training, as it leads to improved skill acquisition and transfer. Secondary task metrics that reflect trainee automaticity should be implemented during simulator training to improve learning and skill transfer.


Assuntos
Automatismo/psicologia , Simulação por Computador , Laparoscopia/educação , Manequins , Transferência de Experiência , Adulto , Animais , Atenção , Competência Clínica , Currículo , Educação Pré-Médica , Feminino , Humanos , Curva de Aprendizado , Masculino , Modelos Animais , Reconhecimento Visual de Modelos , Método Simples-Cego , Técnicas de Sutura , Suínos , Carga de Trabalho/psicologia , Adulto Jovem
11.
Heart Lung Circ ; 21(6-7): 320-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22138425

RESUMO

Implantable cardiac devices for arrhythmias and related conditions are a rapidly evolving field, with a constant stream of technologies being developed. There are a number of novel devices, other than conventional pacemakers and implantable defibrillators, currently being developed that have the potential to greatly improve patient outcomes. This paper reviews the important recent technologies, the subcutaneous defibrillator, cardiac contraction modulation, the HeartPOD and CardioMEMS heart failure monitors, left atrial appendage closure devices and leadless cardiac pacing. The features of these devices, the results to date, and their possible clinical utility are discussed.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas , Humanos
12.
Heart Lung Circ ; 21(11): 700-5, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22784484

RESUMO

BACKGROUND: Catheter angiography is one modality used to diagnose right ventricular (RV) structural abnormalities in suspected arrythmogenic right ventricular dysplasia or cardiomyopathy (ARVC) patients. The appearance of the normal RV on angiography is poorly defined. This study aimed to assess RV morphology in a control group to define the range of normal appearances. METHODS: RV angiography was performed in 46 subjects (mean age 59 years; 70% male) undergoing coronary angiography for suspected coronary artery disease. Qualitative assessment for RV dilatation, regional wall motion abnormalities (RWMAs), pattern of trabeculae, and presence of micro-aneurysms was performed. Right ventricular outflow tract (RVOT) diameter was measured. RESULTS: Regional or global RV dilatation was considered to be present in 17 patients, RWMA in 13, an abnormal trabecular pattern in 10, and microaneurysms noted in two. The RVOT diameter ranged from 1.78 to 3.51 cm in right anterior oblique view and 2.33 to 4.38 cm in left anterior oblique view. CONCLUSION: The apparent prevalence of abnormal RV morphology in individuals who have no known RV pathology implies that detection of such is not necessarily of diagnostic significance in suspected ARVC. Significant inter-observer variation limits the usefulness of qualitative assessment; quantitative assessment is preferred therefore.


Assuntos
Displasia Arritmogênica Ventricular Direita , Angiografia Coronária , Ventrículos do Coração , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/fisiopatologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
13.
Ultrason Sonochem ; 90: 106178, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36194949

RESUMO

Periodontal pockets are spaces or holes surrounded by teeth under the gum line. These pockets can become filled with infection-causing bacteria resulting in tissue, bone, and tooth loss. Cavitation produced by the oscillating tip of dental ultrasonic scalers plays a significant role in routine periodontal therapy to clean these areas. Numerical studies were conducted for a scaler vibrating in a periodontal pocket which was simplified to a hole, using ABAQUS based on the finite element method. The simulations consider the three-dimensional, nonlinear, and transient interaction between the vibration and deformation of the scaler tip, the water flow around the scaler and the cavitation formation. The numerical model was validated by comparing results with experimental data for a scaler vibrating in an unbounded liquid, the displacement at the free end of the scaler and the cavitation pattern near the scaler tip displaying excellent agreement. A parametric study for a scaler vibrating in a hole has been carried out in terms of the volume of the hole, the taper ratio (the radius ratio between the circular opening and bottom of the hole), and the immersion depth of the scaler tip in the hole. The amount of cavitation generated is evaluated by the cavitation density (or the void fraction) which is the ratio of the volume of the cavitation occupied in the hole to the total volume of the hole. Numerical results indicate that the cavitation density in the hole increases with the decreasing hole volume and the increasing taper ratio. It is inferred that cleaning effects could be increased if some modifications to the scaler design could be made to increase the blocking effect of the hole during the cleaning process. Cavitation is observed in the hole even if the scaler is placed above the hole and increases with the immersion depth.


Assuntos
Ultrassom , Vibração , Humanos , Bolsa Periodontal , Ultrassom/métodos
14.
N Engl J Med ; 358(17): 1793-804, 2008 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-18381485

RESUMO

BACKGROUND: The most common location of out-of-hospital sudden cardiac arrest is the home, a situation in which emergency medical services are challenged to provide timely care. Consequently, home use of an automated external defibrillator (AED) might offer an opportunity to improve survival for patients at risk. METHODS: We randomly assigned 7001 patients with previous anterior-wall myocardial infarction who were not candidates for an implantable cardioverter-defibrillator to receive one of two responses to sudden cardiac arrest occurring at home: either the control response (calling emergency medical services and performing cardiopulmonary resuscitation [CPR]) or the use of an AED, followed by calling emergency medical services and performing CPR. The primary outcome was death from any cause. RESULTS: The median age of the patients was 62 years; 17% were women. The median follow-up was 37.3 months. Overall, 450 patients died: 228 of 3506 patients (6.5%) in the control group and 222 of 3495 patients (6.4%) in the AED group (hazard ratio, 0.97; 95% confidence interval, 0.81 to 1.17; P=0.77). Mortality did not differ significantly in major prespecified subgroups. Only 160 deaths (35.6%) were considered to be from sudden cardiac arrest from tachyarrhythmia. Of these deaths, 117 occurred at home; 58 at-home events were witnessed. AEDs were used in 32 patients. Of these patients, 14 received an appropriate shock, and 4 survived to hospital discharge. There were no documented inappropriate shocks. CONCLUSIONS: For survivors of anterior-wall myocardial infarction who were not candidates for implantation of a cardioverter-defibrillator, access to a home AED did not significantly improve overall survival, as compared with reliance on conventional resuscitation methods. (ClinicalTrials.gov number, NCT00047411 [ClinicalTrials.gov].).


Assuntos
Reanimação Cardiopulmonar , Desfibriladores , Parada Cardíaca/terapia , Assistência Domiciliar , Idoso , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Serviços Médicos de Emergência , Feminino , Parada Cardíaca/etiologia , Parada Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Mortalidade , Infarto do Miocárdio/complicações
15.
Heart Lung Circ ; 20(12): 757-60, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21885338

RESUMO

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an uncommon inherited myocardial disorder characterised by fibro-fatty inflammation affecting the right and left ventricles. It most commonly presents with palpitations or syncope but sudden death may occur, especially in young males. METHODS: Diagnosis is not possible with a single test and may be difficult. Task Force criteria agreed in 1994 comprise major and minor criteria spanning structural abnormalities, ECG appearances, arrhythmias, family history of premature death and myocardial histology. Modified criteria were introduced in 2010 to improve sensitivity. RESULTS: Arrhythmogenic right ventricular cardiomyopathy is a desmosomal disease. Mutations have been detected in five desmosomal genes, most frequently in plakophilin-2 (PKP2) and multiple mutations are also reported. Antiarrhythmic drugs such as sotalol and amiodarone may improve symptoms but are unproven to increase survival. An implantable defibrillator is appropriate in individuals surviving cardiac arrest or sustained ventricular tachycardia, but there is not yet consensus about prophylactic treatment of Task Force positive but asymptomatic individuals. CONCLUSIONS: Arrhythmogenic right ventricular cardiomyopathy is more common than previously believed. Preliminary evidence supports improved sensitivity without loss of specificity using the revised Task Force criteria. The genetics of the disease are complex but should ultimately advance diagnosis and management.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Doenças Genéticas Inatas/diagnóstico , Doenças Genéticas Inatas/terapia , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Displasia Arritmogênica Ventricular Direita/genética , Desfibriladores Implantáveis , Desmossomos/genética , Eletrocardiografia/métodos , Feminino , Doenças Genéticas Inatas/genética , Parada Cardíaca/diagnóstico , Parada Cardíaca/genética , Parada Cardíaca/terapia , Humanos , Masculino , Mutação , Linhagem , Placofilinas/genética , Guias de Prática Clínica como Assunto , Fatores Sexuais , Sotalol/uso terapêutico , Taxa de Sobrevida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/genética , Taquicardia Ventricular/terapia
16.
Heart Lung Circ ; 20(9): 593-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21616715

RESUMO

BACKGROUND: It is often reported that clinical symptoms are useful in differentiating cardiac from non-cardiac syncope. Studies in the young are rare. This study was designed to capture the symptoms and signs reported by patients with cardiac syncope before the patients or their attending clinicians knew the final diagnosis. METHODS: Retrospective case-note review of 35 consecutive unrelated gene-positive probands with a proven cardiac channelopathy. RESULTS: The presentation leading to diagnosis of cardiac channelopathy was resuscitated sudden cardiac death in 7 patients; syncope in 20; collapse with retained consciousness in 2; palpitations in 1 and an incidental finding in 5. For the 20 patients with syncope (LQTS 18, Brugada syndrome 2), median age at presentation was 13.9 years (1.8 day to 40.8 years). Of the 17 patients able to describe the onset of syncope, 11 (65%) had at least one symptom prior to collapse, though none reported nausea. Dizziness or lightheadedness was the most frequent symptom, being experienced by 8 (47%). Nine (of 20) patients (45%) had witnessed seizure-like activity and 8 (40%) had urinary incontinence. Nineteen patients were capable of describing the post-syncopal period, of whom 15 (79%) reported symptoms, the most common (12; 65%) being drowsiness or exhaustion. CONCLUSIONS: Cardiac syncope in the young frequently presents with symptoms and signs that are typically associated with other causes of transient loss of consciousness, including vasovagal syncope and seizure disorders. The presence of symptoms may not be as helpful in differentiating arrhythmic from non-arrhythmic events as is often supposed. A thorough history, appropriate investigations and a high index of suspicion remain essential in the assessment of syncope.


Assuntos
Síndrome de Brugada/fisiopatologia , Síndrome do QT Longo/fisiopatologia , Sistema de Registros , Síncope/fisiopatologia , Adolescente , Adulto , Síndrome de Brugada/complicações , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/patologia , Criança , Pré-Escolar , Humanos , Síndrome do QT Longo/complicações , Síndrome do QT Longo/epidemiologia , Síndrome do QT Longo/patologia , Masculino , Nova Zelândia/epidemiologia , Estudos Retrospectivos , Síncope/epidemiologia , Síncope/etiologia , Síncope/patologia
17.
Am Heart J ; 159(4): 627-634.e7, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20362722

RESUMO

BACKGROUND: Public access automatic external defibrillators (AEDs) can save lives, but most deaths from out-of-hospital sudden cardiac arrest occur at home. The Home Automatic External Defibrillator Trial (HAT) found no survival advantage for adding a home AED to cardiopulmonary resuscitation (CPR) training for 7,001 patients with a prior anterior wall myocardial infarction. Quality of life (QOL) outcomes for both the patient and spouse/companion were secondary end points. METHODS: A subset of 1,007 study patients and their spouse/companions was randomly selected for ascertainment of QOL by structured interview at baseline and 12 and 24 months after enrollment. The primary QOL measures were the Medical Outcomes Study 36-Item Short-Form psychological well-being (reflecting anxiety and depression) and vitality (reflecting energy and fatigue) subscales. RESULTS: For patients and spouse/companions, the psychological well-being and vitality scales did not differ significantly between those randomly assigned an AED plus CPR training and controls who received CPR training only. None of the other QOL measures collected showed a clinically and statistically significant difference between treatment groups. Patients in the AED group were more likely to report being extremely or quite a bit reassured by their treatment assignment. Spouse/companions in the AED group reported being less often nervous about the possibility of using AED/CPR treatment than those in the CPR group. CONCLUSIONS: Adding access to a home AED to CPR training did not affect QOL either for patients with a prior anterior myocardial infarction or their spouse/companion but did provide more reassurance to the patients without increasing anxiety for spouse/companions.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Qualidade de Vida/psicologia , Estresse Psicológico/etiologia , Idoso , Feminino , Amigos , Humanos , Masculino , Pessoa de Meia-Idade , Cônjuges
18.
Heart Lung Circ ; 19(7): 438-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19656723

RESUMO

The diagnosis of cardiac tumours is often based on images without tissue diagnosis or tissue obtained at surgery. Percutaneous myocardial biopsy via a transvenous approach has been described in literatures but this technique is not feasible with left atrial tumours. We report a patient presenting with heart failure and left atrial tumour. The diagnosis of spindle cell neoplasm was established pre-operatively via successful transseptal fine needle aspiration of cells from a left atrial tumour. We believe this technique worth consideration to aid pre-surgery diagnosis.


Assuntos
Biópsia por Agulha Fina/métodos , Átrios do Coração/cirurgia , Neoplasias Cardíacas/cirurgia , Sarcoma/cirurgia , Adulto , Fluoroscopia , Neoplasias Cardíacas/patologia , Humanos , Masculino , Sarcoma/patologia , Ultrassonografia de Intervenção
19.
Patient Educ Couns ; 103(11): 2305-2311, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32475712

RESUMO

OBJECTIVE: To determine if a novel interdisciplinary "speed-dating" clinic augments Diabetes Self-Management Education and Support (DSMES). METHODS: Adult patients with diabetes attended a DSMES class. Two weeks later patients attended an interdisciplinary clinic utilizing a "speed-dating" format during which they progressed through 5 stations hosted by different healthcare disciplines at 30-minute increments: physician, pharmacist, nurse/dietitian, case manager, and psychologist. Shared decision-making was utilized to identify mutually agreeable recommendations. Change in clinical outcomes were compared for DSMES-only attenders versus Dual-attendees; utilization of emergency department and hospital services were measured 12 months before and after attending the Speed Dating clinic. This analysis represents patients attending the program during 2016. RESULTS: Sixty-nine attended the DSMES class, 40 of whom followed-up in the "speed-dating" clinic (58% return rate). Attending the Speed Dating clinic improved A1C (p = 0.003) and LDL-C (p = 0.003) compared to the DSMES class alone. Comparatively, after attending the speed-dating clinic, patients had fewer emergency department (p = 0.366) and hospital admissions (p = 0.036), and shorter lengths of hospital stay (p = 0.030). CONCLUSIONS: The interdisciplinary "speed-dating" approach improved diabetes outcomes beyond DSMES alone and reduced utilization of hospital services. PRACTICE IMPLICATIONS: Patients should attend DSMES but also participate in an Interdisciplinary Speed Dating follow-up to further improve outcomes.


Assuntos
Atenção à Saúde/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Equipe de Assistência ao Paciente , Educação de Pacientes como Assunto , Autocuidado , Autogestão/educação , Adulto , Idoso , Gerentes de Casos , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 2/psicologia , Feminino , Educadores em Saúde , Humanos , Comunicação Interdisciplinar , Masculino , Pessoa de Meia-Idade , Nutricionistas , Avaliação de Resultados em Cuidados de Saúde , Farmacêuticos
20.
Chem Asian J ; 15(19): 3059-3081, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32749069

RESUMO

Syntheses of a range of chemically well-defined oligopyrrole/benzenoid hybrids are described using tandem Suzuki-Miyaura cross-coupling/bromo-desilyation reaction sequences for linking borylated pyrroles, halogenated pyrroles and/or dibromobenzenes to one another. By such means, including iterative variants, a range of all α-linked, all ß-linked oligopyrroles as well as certain combinations thereof have been assembled, some of them for the first time. The conductivities of iodine-treated thin films formed from certain such systems have been determined.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA