Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Vet Surg ; 44(2): 206-13, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25132492

RESUMO

OBJECTIVES: To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: Experimental. SAMPLE POPULATION: Adult equine cadaveric MC3 bones (n = 12 pair). METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. RESULTS: Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. CONCLUSION: HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending.


Assuntos
Materiais Biocompatíveis , Placas Ósseas/veterinária , Durapatita , Fixação Interna de Fraturas/veterinária , Cavalos/lesões , Ossos Metacarpais/lesões , Animais , Fenômenos Biomecânicos , Cadáver , Cavalos/cirurgia , Técnicas In Vitro , Ossos Metacarpais/cirurgia , Osteotomia/veterinária
2.
Vet Surg ; 43(4): 465-70, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24720361

RESUMO

OBJECTIVE: To compare the 3.5 string of pearls (SOP) plate with a 3.5 mm locking compression plate (LCP) using a fracture model in static loading and cyclic fatigue testing. STUDY DESIGN: In vitro biomechanical testing of paired tibias with a mid-diaphyseal ostectomy, stabilized by 1 of 2 locking systems. SAMPLE POPULATION: Cadaveric canine tibiae (n = 24 pairs). METHODS: Tibias were randomly divided into 4 equal groups: (1) 4-point bending single cycle to failure, (2) 4-point bending cyclic fatigue, (3) torsion single cycle to failure, and (4) torsion cyclic fatigue. Randomly assigned SOP and LCP bridged a 20 mm mid-diaphyseal ostectomy. Mean test variables values for each method were compared using a paired t-test within each group with significance set at P < .05. RESULTS: The SOP construct had significantly greater mean yield load, mean yield displacement, mean yield bending moment, mean composite rigidity and mean failure bending moment under static 4-point bending to failure than the LCP construct. Mean number of cycles to failure under 4-point bending was significantly greater for the SOP constructs but the mean number of cycles to failure in torsion was significantly greater for the LCP constructs. The LCP construct had significantly greater mean composite stiffness and significantly lesser mean displacement to yield and to failure in static torsion testing. CONCLUSION: The SOP construct was superior under bending static and cycling testing but the LCP construct was superior in static and cycling torsion testing.


Assuntos
Placas Ósseas/veterinária , Cães , Fixação Interna de Fraturas/veterinária , Animais , Fenômenos Biomecânicos , Cadáver , Falha de Equipamento/veterinária , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos
3.
Vet Surg ; 40(3): 261-5, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21361995

RESUMO

OBJECTIVES: To compare the mean number of cycles to failure under axial compression of equine proximal interphalangeal (PIP) joint arthrodesis constructs created by 2 parallel transarticular Acutrak Plus screws (AP-TS) or 2 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (AO-TLS). STUDY DESIGN: Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. SAMPLE POPULATION: Cadaveric adult equine forelimbs (n=5 pairs). METHODS: For each forelimb pair, 1 PIP joint was stabilized with AP-TS and 1 with AP-TLS. The 5 construct pairs were tested for cyclic fatigue under axial compression. Mean number of cycles to failure for each fixation method were compared by a paired t-test within each group with statistical significance set at P<.05. RESULTS: The mean number of cycles to failure under axial compression for AO-TLS fixation and AP-TS fixation were 57,723±8488 and 35,322±4698, respectively. CONCLUSION: The AO-TLS was superior to the AP-TS in resisting cyclic fatigue under axial compression.


Assuntos
Artrodese/veterinária , Parafusos Ósseos/veterinária , Cavalos/cirurgia , Articulação do Dedo do Pé/cirurgia , Animais , Artrodese/instrumentação , Artrodese/métodos , Cadáver , Membro Anterior/cirurgia
4.
Vet Surg ; 40(5): 571-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21521241

RESUMO

OBJECTIVES: To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow locking compression plate (ELCP) using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (ELCP-TLS) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) for equine proximal interphalangeal (PIP) joint arthrodesis. DESIGN: Experimental. ANIMAL POPULATION: Cadaveric adult equine forelimbs (n = 18 pairs). METHODS: For each forelimb pair, 1 PIP joint was stabilized with an axial ELCP using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 PIP joint with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression, 6 construct pairs were tested for cyclic fatigue under axial compression, and 6 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P < .05. RESULTS: Mean yield load, yield stiffness, and failure load under axial compression, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the LCP-TLS fixation. There was no significant difference between the mean number of cycles to failure in axial compression of the LCP-TLS and the DCP-TLS fixations. Mean yield load, yield stiffness, and failure load under torsion, single cycle to failure, of the LCP-TLS fixation were significantly greater than those of the DCP-TLS fixation. CONCLUSION: The DCP-TLS construct provided significantly greater stability under axial compression in single cycle to failure than the ELCP-TLS construct, the ELCP-TLS construct provided significantly greater stability under torsional loading in single cycle to failure than the DCP-TLS construct, and there was no significant difference in stability between the 2 constructs for cyclic loading under axial compression.


Assuntos
Artrodese/veterinária , Placas Ósseas/veterinária , Parafusos Ósseos/veterinária , Cavalos/cirurgia , Articulação do Dedo do Pé/cirurgia , Animais , Artrodese/instrumentação , Artrodese/métodos , Fenômenos Biomecânicos , Força Compressiva , Técnicas In Vitro , Fenômenos Mecânicos , Articulação do Dedo do Pé/fisiologia , Torção Mecânica , Suporte de Carga
5.
Vet Surg ; 40(5): 579-85, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21539578

RESUMO

OBJECTIVES: To compare the number of cycles to failure of 4.5 mm broad dynamic compression plates (DCP), 4.5 mm broad limited-contact dynamic compression plates (4.5-LC-DCP), and 5.5 mm broad limited-contact dynamic compression plates (5.5-LC-DCP) having a rough (denoted by a prefix R-) versus a standard smooth contact surface for the fixation of osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: Experimental. ANIMAL POPULATION: Fifteen pairs of adult equine cadaveric MC3 bones. METHODS: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for comparison of (1) R-DCP fixation with DCP fixation, (2) R-4.5-LC-DCP fixation with 4.5-LC-DCP fixation, and (3) R-5.5-LC-DCP fixation with 5.5-LC-DCP fixation to repair osteotomized equine MC3 bones under palmarodorsal 4-point bending cyclic fatigue testing. For each group an 8-hole plate with rough contact surface was applied to the dorsal surface of one randomly selected bone from each pair and a corresponding 8-hole plate with smooth contact surface was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid-diaphyseal osteotomies. Mean number of cycles to failure for each method were compared using a paired t-test within each group. Significance was set at P < .05. RESULTS: Mean cycles to failure ± standard deviation was significantly greater for the R-DCP fixation (230,025 ± 23,129) compared with the DCP fixation (103,451 ± 14,556), for the R-4.5-LC-DCP fixation (99,237 ± 14,390) compared with the 4.5-LC-DCP fixation (46,464 ± 6325) and for the R-5.5-LC-DCP fixation (65,113 ± 7796) compared with the 5.5-LC-DCP fixation (34,224 ± 3835). CONCLUSION: For the fixation of osteotomized MC3 bones, the constructs with plates having rough contact surface were superior to the corresponding constructs with plates having standard smooth contact surfaces in resisting cyclic fatigue under palmarodorsal 4-point bending.


Assuntos
Placas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Cavalos/cirurgia , Ossos Metacarpais/lesões , Osteotomia/veterinária , Animais , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Técnicas In Vitro , Ossos Metacarpais/cirurgia , Desenho de Prótese , Falha de Prótese , Distribuição Aleatória
6.
Vet Surg ; 39(1): 78-82, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20210949

RESUMO

OBJECTIVES: To compare compression pressure (CP) of 6.5 mm Acutrak Plus (AP) and 4.5 mm AO cortical screws (AO) when inserted in simulated lateral condylar fractures of equine 3rd metacarpal (MC3) bones. STUDY DESIGN: Paired in vitro biomechanical testing. SAMPLE POPULATION: Cadaveric equine MC3 bones (n=12 pair). METHODS: Complete lateral condylar osteotomies were created parallel to the midsagittal ridge at 20, 12, and 8 mm axial to the epicondylar fossa on different specimens grouped accordingly. Interfragmentary compression was measured using a pressure sensor placed in the fracture plane before screw placement for fracture fixation. CP was acquired and mean values of CP for each fixation method were compared between the 6.5 mm (AP) and 4.5 mm (AO) for each group using a paired t-test within each fracture fragment thickness group with statistical significance set at P<.05. RESULTS: AO screw configurations generated significantly greater compressive pressure compared with AP configurations. The ratio of mean CP for AP screws to AO screws at 20, 12, and 8 mm, were 21.6%, 26.2%, and 34.2%, respectively. CONCLUSION: Mean CP for AP screw fixations are weaker than those for AO screw fixations, most notably with the 20 mm fragments. The 12 and 8 mm groups have comparatively better compression characteristics than the 20 mm group; however, they are still significantly weaker than AO fixations. CLINICAL RELEVANCE: Given that the primary goals of surgical repair are to achieve rigid fixation, primary bone healing, and good articular alignment, based on these results, it is recommended that caution should be used when choosing the AP screw for repair of lateral condylar fractures, especially complete fractures. Because interfragmentary compression plays a factor in the overall stability of a repair, it is recommended for use only in patients with thin lateral condyle fracture fragments, as the compression tends to decrease with an increase in thickness.


Assuntos
Parafusos Ósseos/veterinária , Fraturas Ósseas/veterinária , Doenças dos Cavalos/cirurgia , Ossos Metacarpais/lesões , Animais , Fenômenos Biomecânicos , Força Compressiva/fisiologia , Fraturas Ósseas/cirurgia , Cavalos/cirurgia , Ossos Metacarpais/cirurgia , Osteotomia/métodos , Osteotomia/veterinária
7.
Vet Surg ; 39(7): 833-8, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20459499

RESUMO

OBJECTIVES: To compare number of cycles to failure for palmarodorsal 4-point bending of a modified 5.5 mm broad locking compression plate (M5.5-LCP) fixation with a 5.5 mm broad LCP (5.5-LCP) fixation used to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing. ANIMAL POPULATION: Adult equine cadaveric MC3 bones (n=6 pairs). METHODS: An 8-hole, M5.5-LCP, obtained by having a 1.0 mm thickness removed from the bone contact portion of the 5.5-LCP, was applied to the dorsal surface of 1 randomly selected MC3 from each pair, and an 8-hole, 5.5-LCP was applied dorsally to the contralateral bone from each pair using a combination of cortical and locking screws. Plates and screws were applied using standard ASIF techniques to MC3 bones with a mid-diaphyseal osteotomy. MC3 constructs had palmarodorsal 4-point bending cyclic fatigue testing. Mean cycles to failure for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean±SD cycles to failure of the M5.5-LCP fixation (188,641±17,971) was significantly greater than that of the 5.5-LCP fixation (166,497±15,539). CONCLUSION: M5.5-LCP fixation was superior to 5.5-LCP fixation of osteotomized equine MC3 bones in resisting cyclic fatigue under palmarodorsal 4-point bending. CLINICAL RELEVANCE: This suggests that biological plate fixation is not the ideal choice for osteotomized equine MC3 bones.


Assuntos
Placas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Cavalos/cirurgia , Fixadores Internos/veterinária , Ossos Metacarpais/cirurgia , Animais , Fenômenos Biomecânicos , Força Compressiva , Fixação Interna de Fraturas/métodos , Teste de Materiais/veterinária , Osteotomia/veterinária
8.
Vet Surg ; 39(5): 581-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20459505

RESUMO

OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a 5.5-mm-broad locking compression plate (5.5 LCP) fixation with a 4.5-mm-broad locking compression plate (4.5 LCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a middiaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Fifteen pairs of adult equine cadaveric MC3 bones. METHODS: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An 8-hole, 5.5 LCP was applied to the dorsal surface of 1 randomly selected bone from each pair and an 8-hole, 4.5 LCP was applied dorsally to the contralateral bone from each pair using a combination of cortical and locking screws. All plates and screws were applied using standard ASIF techniques. All MC3 bones had middiaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group with significance set at P<.05. RESULTS: Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4-point bending, single cycle to failure, of the 5.5 LCP fixation were significantly greater than those of the 4.5 LCP fixation. Mean cycles to failure in 4-point bending of the 5.5 LCP fixation (170,535+/-19,166) was significantly greater than that of the 4.5 LCP fixation (129,629+/-14,054). Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad 5.5 LCP fixation compared with the 4.5 LCP fixation. In single cycle to failure under torsion, the mean+/-SD values for the 5.5 LCP and the 4.5 LCP fixation techniques, respectively, were: yield load, 151.4+/-19.6 and 97.6+/-12.1 N m; composite rigidity, 790.3+/-58.1 and 412.3+/-28.1 N m/rad; and failure load: 162.1+/-20.2 and 117.9+/-14.6 N m. CONCLUSION: The 5.5 LCP was superior to the 4.5 LCP in resisting static overload forces (palmarodorsal 4-point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4-point bending. CLINICAL RELEVANCE: These in vitro study results may provide information to aid in selection of an LCP for repair of equine long bone fractures.


Assuntos
Placas Ósseas/veterinária , Cavalos/cirurgia , Ossos Metacarpais/cirurgia , Osteotomia/veterinária , Animais , Fenômenos Biomecânicos , Técnicas In Vitro , Torção Mecânica , Suporte de Carga
9.
Vet Surg ; 39(1): 83-90, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20210950

RESUMO

OBJECTIVES: To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. STUDY DESIGN: Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. SAMPLE POPULATION: Cadaveric adult equine forelimbs (n=15 pairs). METHODS: For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. RESULTS: Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. CONCLUSION: The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. CLINICAL RELEVANCE: The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.


Assuntos
Artrodese/veterinária , Placas Ósseas/veterinária , Parafusos Ósseos/veterinária , Cavalos/cirurgia , Articulação do Dedo do Pé/cirurgia , Animais , Artrodese/instrumentação , Artrodese/métodos , Fenômenos Biomecânicos/fisiologia , Força Compressiva/fisiologia , Falha de Equipamento/veterinária , Membro Anterior , Doenças dos Cavalos/fisiopatologia , Doenças dos Cavalos/cirurgia , Cavalos/fisiologia , Técnicas In Vitro , Articulação do Dedo do Pé/fisiologia , Torção Mecânica
10.
Am J Vet Res ; 70(6): 697-702, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19496657

RESUMO

OBJECTIVE: To determine the feasibility of performing serial laminar and skin biopsies on sedated horses and whether sampling affected adjacent tissues. ANIMALS: 6 horses. PROCEDURES: Laminar tissues were harvested via biopsy through the hoof wall from healthy conscious horses via sedation and regional anesthesia. Eight specimens were collected at 4 time points during 24 hours from a single foot. Laminar biopsy specimens were harvested with a 6-mm-diameter biopsy punch after burring through the horny corium to the stratum medium. Skin biopsy specimens were collected from an area proximal to the coronary band. All tissues were examined via light microscopy. Total RNA was extracted and quantified, and gene expression analysis was completed for 2 housekeeping genes and the inflammatory mediator cyclooxygenase-2. RESULTS: Laminar and skin biopsies yielded adequate specimens for histologic and gene expression evaluation. There was no extension of inflammation or detectable damage to adjacent tissues during the 24-hour period in either laminar or skin specimens as judged via histologic findings and cyclooxygenase-2 expression. Lameness and discomfort induced by the procedure were minimal. CONCLUSIONS AND CLINICAL RELEVANCE: Laminar biopsy provided a satisfactory method of collecting laminar specimens and allowed serial sampling of individual horses.


Assuntos
Biópsia/veterinária , Pé/anatomia & histologia , Cavalos/anatomia & histologia , Pele/anatomia & histologia , Animais , Biópsia/métodos , Casco e Garras/anatomia & histologia , Microscopia
11.
Vet Surg ; 38(5): 659-63, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19573071

RESUMO

OBJECTIVES: To report a technique for arthrodesis of the distal interphalangeal joint (DIPJ) with two 6.5 mm Acutrak Plus (AP) compression screws from a solar approach and outcome in 7 cattle. STUDY DESIGN: Case series. ANIMALS: Cattle (n=7) with DIPJ arthritis. METHODS: Retrieved data from medical records of cattle that had undergone DIPJ arthrodesis using 2 AP screws via a solar approach were signalment, history, clinical signs, preoperative blood work, preoperative radiographs, complications, postoperative radiographs, and postoperative lameness evaluation. Outcomes, assessed by owner interview 6-26 months after surgery, were classified as excellent, good, or poor. RESULTS: Fusion of the DIPJ was evident by 6 months. All cattle returned to full function with minimal lameness and normal appearance to the distal aspect of the limb. Four thoracic limbs and 3 pelvic limbs were affected; 3 medial and 4 lateral claws. Complications included moderate lameness associated with implants (n=2) that resolved after screw removal. CLINICAL RELEVANCE: Use of the AP screw system in cattle is an excellent option for DIPJ arthrodesis with minimal postoperative morbidity and excellent return to function.


Assuntos
Artrodese/veterinária , Parafusos Ósseos/veterinária , Doenças dos Bovinos/cirurgia , Artropatias/veterinária , Animais , Artrodese/efeitos adversos , Artrodese/instrumentação , Artrodese/métodos , Bovinos , Feminino , Artropatias/cirurgia , Masculino , Estudos Retrospectivos
12.
Vet Surg ; 37(3): 283-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18394076

RESUMO

OBJECTIVE: To compare monotonic biomechanical properties and fatigue life of a broad locking compression plate (LCP) fixation with a broad limited contact dynamic compression plate (LC-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Cadaveric adult equine MC3 bones (n=12 pairs). METHODS: MC3 were divided into 3 groups (4 pairs each) for: (1) 4-point bending single cycle to failure testing; (2) 4-point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8-hole, 4.5 mm LCP was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8-hole, 4.5 mm LC-DCP) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment, under 4-point bending, single cycle to failure, of the LCP fixation were significantly greater than those of the LC-DCP fixation. Mean cycles to failure for 4-point bending was significantly greater for the LCP fixation compared with LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad LCP fixation compared with the LC-DCP fixation. CONCLUSION: The 4.5 mm LCP was superior to the 4.5 mm LC-DCP in resisting the static overload forces (palmarodorsal 4-point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4-point bending. CLINICAL RELEVANCE: The results of this in vitro study may provide information to aid in the selection of a biological plate for the repair of equine long bone fractures.


Assuntos
Placas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Fixadores Internos/veterinária , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Animais , Fenômenos Biomecânicos , Cadáver , Força Compressiva , Falha de Equipamento/veterinária , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Cavalos , Osteotomia/métodos , Osteotomia/veterinária , Distribuição Aleatória
13.
Vet Surg ; 37(3): 289-93, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18394077

RESUMO

OBJECTIVES: To compare monotonic biomechanical properties and fatigue life of a 5.5 mm broad limited-contact dynamic compression plate (5.5-LC-DCP) fixation with a 4.5 mm broad LC-DCP (4.5-LC-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. SAMPLE POPULATION: Adult equine cadaveric MC3 bones (n=18 pair). METHODS: MC3 were divided into 3 test groups (6 pairs each) for: (1) 4-point bending single cycle to failure testing; (2) 4-point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8-hole, 5.5 mm broad LC-DCP (5.5-LC-DCP) was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8-hole, 4.5 mm broad LC-DCP (4.5-LC-DCP) was applied dorsally to the contralateral bone from each pair. Plates and screws were applied using standard ASIF techniques. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment under 4-point bending, single cycle to failure, of the 5.5-LC-DCP fixation were significantly greater (P<.024) than those of the 4.5-LC-DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.05) greater for the 4.5-LC-DCP fixation compared with the 5.5-LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion for the 5.5-LC-DCP fixation was not significantly different (P>.05) than those with the 4.5-LC-DCP fixation. CONCLUSION: 5.5-LC-DCP fixation was superior to 4.5-LC-DCP fixation in resisting the static overload forces under palmarodorsal 4-point bending. There was no significant difference between 5.5-LC-DCP fixation and 4.5-LC-DCP fixation in resisting static overload forces under torsion; however, the 5.5-LC-DCP offers significantly less stability (80% of that of the 4.5-LC-DCP) in cyclic fatigue testing. CLINICAL RELEVANCE: The results of this in vitro study may provide information to aid in the selection of a biological plate for long bone fracture repair in horses.


Assuntos
Placas Ósseas/veterinária , Força Compressiva , Fixação Interna de Fraturas/veterinária , Fixadores Internos/veterinária , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Animais , Fenômenos Biomecânicos , Placas Ósseas/normas , Cadáver , Falha de Equipamento/veterinária , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Cavalos , Osteotomia/métodos , Osteotomia/veterinária , Distribuição Aleatória
14.
Vet Surg ; 36(8): 792-9, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18067621

RESUMO

OBJECTIVES: To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. STUDY DESIGN: Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. ANIMAL POPULATION: Cadaveric adult equine forelimbs (n=18 pairs). METHODS: For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. RESULTS: Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m/rad; and failure load: 256.4 +/- 39.2 and 87.1 +/- 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 +/- 65,468) was significantly greater than DCP-TLS (95,418 +/- 11,037). CONCLUSION: ESP was superior to an axial 3-hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. CLINICAL RELEVANCE: In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.


Assuntos
Artrodese/veterinária , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/veterinária , Cavalos/lesões , Cavalos/cirurgia , Articulação do Dedo do Pé/cirurgia , Animais , Artrodese/instrumentação , Artrodese/métodos , Fenômenos Biomecânicos , Pinos Ortopédicos/veterinária , Placas Ósseas/veterinária , Parafusos Ósseos/veterinária , Cadáver , Força Compressiva , Membro Anterior , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Estresse Mecânico
15.
Can Vet J ; 45(10): 849-51, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15532886

RESUMO

Phosphate enema toxicity was diagnosed in a 7-month-old, castrated male, pygmy goat. On presentation, clinical findings included mild depression, tachycardia, tachypnea, rumen stasis, muscle tremors, hypocalcemia, hypokalemia, hypochloremia, hyperphosphatemia, azotemia, and metabolic acidosis. Fluid diuresis and parenteral antimicrobial therapy resulted in recovery after 3 d of treatment.


Assuntos
Doenças das Cabras/diagnóstico , Fosfatos/intoxicação , Acidose/induzido quimicamente , Acidose/diagnóstico , Acidose/veterinária , Animais , Constipação Intestinal/terapia , Constipação Intestinal/veterinária , Diagnóstico Diferencial , Enema/efeitos adversos , Enema/veterinária , Doenças das Cabras/induzido quimicamente , Doenças das Cabras/patologia , Cabras , Masculino , Fosfatos/administração & dosagem , Intoxicação/diagnóstico , Intoxicação/veterinária
17.
Vet Surg ; 35(7): 634-42, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17026548

RESUMO

OBJECTIVES: To compare biomechanical properties of a prototype 5.5 mm tapered shaft cortical screw (TSS) and 5.5 mm AO cortical screw for an equine third metacarpal dynamic compression plate (EM-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: Paired in vitro biomechanical testing of cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Adult equine cadaveric MC3 bones (n=12 pairs). METHODS: Twelve pairs of equine MC3 were divided into 3 groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of each, mid-diaphyseal osteotomized, MC3 pair. For each MC3 bone pair, 1 was randomly chosen to have the EM-DCP secured with four 5.5 mm TSS (2 screws proximal and distal to the osteotomy; TSS construct), two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws in the remaining holes. The control construct (AO construct) had four 5.5 mm AO cortical screws to secure the EM-DCP in the 2 holes proximal and distal to the osteotomy in the contralateral bone from each pair. The remaining holes of the EM-DCP were filled with two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws. All plates and screws were applied using standard AO/ASIF techniques. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the TSS construct were significantly greater (P<.00004 for yield and P<.00001 for failure loads) than those of the AO construct. Mean cycles to failure in 4-point bending of the TSS construct was significantly greater (P<.0002) than that of the AO construct. The mean yield load and composite rigidity in torsion of the TSS construct were significantly greater (P<.0039 and P<.00003, respectively) than that of the AO construct. CONCLUSION: The TSS construct provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: The results of this in vitro study support the conclusion that the EM-DCP fixation using the prototype 5.5 mm TSS is biomechanically superior to the EM-DCP fixation using 5.5 mm AO cortical screws for the stabilization of osteotomized equine MC3.


Assuntos
Parafusos Ósseos/veterinária , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/veterinária , Ossos Metacarpais/cirurgia , Osteotomia/veterinária , Animais , Fenômenos Biomecânicos , Placas Ósseas/normas , Placas Ósseas/veterinária , Parafusos Ósseos/normas , Cadáver , Força Compressiva , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/normas , Fraturas Ósseas/cirurgia , Cavalos , Fixadores Internos/normas , Fixadores Internos/veterinária , Osteotomia/métodos , Distribuição Aleatória , Estresse Mecânico , Anormalidade Torcional
18.
Vet Surg ; 34(6): 594-603, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16343147

RESUMO

OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.


Assuntos
Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/veterinária , Cavalos/lesões , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Osteotomia/veterinária , Animais , Fenômenos Biomecânicos , Pinos Ortopédicos/veterinária , Placas Ósseas/veterinária , Cadáver , Força Compressiva/fisiologia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Cavalos/cirurgia , Osteotomia/métodos , Distribuição Aleatória , Anormalidade Torcional/veterinária
19.
Vet Surg ; 34(6): 579-86, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16343145

RESUMO

OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.


Assuntos
Fraturas Ósseas/veterinária , Cavalos/lesões , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Osteotomia/veterinária , Animais , Fenômenos Biomecânicos , Pinos Ortopédicos/veterinária , Placas Ósseas/veterinária , Cadáver , Força Compressiva , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/cirurgia , Cavalos/cirurgia , Osteotomia/métodos , Distribuição Aleatória , Anormalidade Torcional/veterinária
20.
Vet Surg ; 34(6): 587-93, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16343146

RESUMO

OBJECTIVES: To evaluate the effects of plate luting on the biomechanical properties of a broad limited contact-dynamic compression plate (LC-DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by LC-DCP fixation, with 1 of the pair luted with polymethylmethacrylate (PMMA). ANIMAL POPULATION: Ten pairs of adult equine cadaveric MC3 bones. METHODS: Ten pairs of equine MC3 were divided into 2 test groups (5 pairs each) for (1) palmarodorsal 4-point bending single cycle to failure testing and (2) palmarodorsal 4-point bending cyclic fatigue testing. The LC-DCP (8 hole, 4.5 mm) was applied to the dorsal surface of each pair of MC3 bones. All plates and screws were applied using standard AO/ASIF techniques. All MC3 bones had mid-diaphyseal osteotomies. One of the matched pairs of LC-DCP-MC3 constructs were randomly chosen to be luted with PMMA. Mean test variable values for each method were compared using a paired t-test within each group; significance was set at P<.05. RESULTS: Mean palmarodorsal 4-point bending yield bending moment, failure bending moment of the LC-DCP fixation with luting was not significantly different (P>.05) than those of the LC-DCP fixation without luting. Mean cycles to failure for palmarodorsal 4-point bending was significantly (P<.0003) greater, with a 7.2-fold increase, for the LC-DCP fixation with luting compared with the LC-DCP fixation without luting. CONCLUSION: Luting the broad LC-DCP with PMMA in the fixation osteotomized equine MC3 bones increases the fatigue life of cyclic loading for palmarodorsal 4-point bending under the in vitro conditions studied. CLINICAL RELEVANCE: The cyclic fatigue data supports the conclusion that luted broad LC-DCP fixation is biomechanically superior to the non-luted broad LC-DCP fixation in osteotomized equine MC3 bones.


Assuntos
Cimentos Ósseos/uso terapêutico , Cavalos/lesões , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Osteotomia/veterinária , Polimetil Metacrilato/uso terapêutico , Animais , Fenômenos Biomecânicos , Pinos Ortopédicos/veterinária , Placas Ósseas/veterinária , Cadáver , Força Compressiva/fisiologia , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/cirurgia , Fraturas Ósseas/veterinária , Cavalos/cirurgia , Osteotomia/métodos , Distribuição Aleatória , Anormalidade Torcional/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA