Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Molecules ; 27(4)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35209238

RESUMO

For the identification of antigenic protein biomarkers for rheumatoid arthritis (RA), we conducted IgG profiling on high density protein microarrays. Plasma IgG of 96 human samples (healthy controls, osteoarthritis, seropositive and seronegative RA, n = 24 each) and time-series plasma of a pristane-induced arthritis (PIA) rat model (n = 24 total) were probed on AIT's 16k protein microarray. To investigate the analogy of underlying disease pathways, differential reactivity analysis was conducted. A total of n = 602 differentially reactive antigens (DIRAGs) at a significance cutoff of p < 0.05 were identified between seropositive and seronegative RA for the human samples. Correlation with the clinical disease activity index revealed an inverse correlation of antibodies against self-proteins found in pathways relevant for antigen presentation and immune regulation. The PIA model showed n = 1291 significant DIRAGs within acute disease. Significant DIRAGs for (I) seropositive, (II) seronegative and (III) PIA were subjected to the Reactome pathway browser which also revealed pathways relevant for antigen presentation and immune regulation; of these, seven overlapping pathways had high significance. We therefore conclude that the PIA model reflects the biological similarities of the disease pathogenesis. Our data show that protein array analysis can elucidate biological differences and pathways relevant in disease as well be a useful additional layer of omics information.


Assuntos
Artrite Reumatoide/diagnóstico , Artrite Reumatoide/etiologia , Autoanticorpos/imunologia , Autoimunidade , Biomarcadores , Animais , Autoanticorpos/sangue , Autoantígenos/imunologia , Biologia Computacional/métodos , Modelos Animais de Doenças , Suscetibilidade a Doenças/imunologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Análise Serial de Proteínas , Ratos , Índice de Gravidade de Doença
2.
Anal Chem ; 93(12): 5161-5169, 2021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33724777

RESUMO

A DNA aptazyme consists of an aptamer domain and a DNAzyme module, in which the DNAzyme activity can be regulated by the aptamer-target interaction. The complex of G-quadruplex (GQ) and hemin is a peroxidase-mimicking DNAzyme and has become increasingly popular as a reporter system for biosensing applications. The development of GQ-based aptazymes is of high interest as they can be used as label-free biosensors for the real-time detection of pathogens. Herein, we rationally designed ca. 200 GQ-based aptazyme candidates and evaluated the suitability of 14 aptamers targeting quinine, Protein A, Staphylococcus enterotoxin B, and ATP for this detection concept. As a result, six novel aptazymes were developed for the specific detection of quinine based on two quinine-binding aptamers. The rest of designed probes, however, hardly showed significant functionality. To uncover the reasons, we performed enzyme-linked oligonucleotide assays to find how the affinity of aptamers is affected once conjugated to the DNAzyme sequence or upon integration into the aptazyme probe. Furthermore, we investigated the impact of the structure-switching functionality in the parent aptamer and the effect of the reaction matrix on the efficiency of probes.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , DNA Catalítico , Quadruplex G , Colorimetria , DNA , DNA Catalítico/metabolismo , Hemina , Quinina
3.
Allergy ; 74(4): 780-787, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30394551

RESUMO

BACKGROUND: The preventive effect of allergen immunotherapy (AIT) on allergy and asthma development is currently assessed using primary and secondary AIT approaches. Knowledge of the immunological effects of these interventions is limited and the impact on epitope diversity remains to be defined. METHODS: We used high-density peptide arrays that included all known Dermatophagoides pteronyssinus (Der p) and Dermatophagoides farinae (Der f) allergens and the whole proteome of Der f to study changes in House Dust Mite (HDM) linear peptide recognition during a 2-year preventive double-blind placebo-controlled sublingual HDM AIT pilot study in 2-5-year-old children with sensitization to HDM but without symptoms. RESULTS: Preventive AIT-treated patients showed significantly higher IgG epitope diversity to HDM allergens compared to placebo-treated individuals at 24 months of treatment (P < 0.05), while no increase in IgE diversity was seen. At 24 months of treatment, IgG4 diversity for HDM allergens was significantly higher in the pAIT-treated patients compared to placebo group (P < 0.05). Potentially beneficial changes in epitope recognition throughout the treatment are also seen in peptides derived from Der f proteome. CONCLUSION: These data suggest a beneficial immunomodulation of preventive sublingual immunotherapy at a molecular level by favoring a broader blocking repertoire and inhibiting epitope spreading.


Assuntos
Epitopos/efeitos dos fármacos , Pyroglyphidae/imunologia , Imunoterapia Sublingual/métodos , Animais , Antígenos de Dermatophagoides/imunologia , Pré-Escolar , Dermatophagoides pteronyssinus/imunologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Projetos Piloto
4.
Methods Mol Biol ; 2628: 413-438, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36781800

RESUMO

Antibody (AB) testing or serotesting for reactive ABs against antigenic proteins is broadly used. Parallel examination of many antigens is of high interest to identify autoantibodies (AAB) or differential antigenic reactivities in many biological settings like allergy and infectious autoimmune, cancerous, or systemic disease. The resulting AAB profiles can be used for diagnosis, prognosis, and monitoring of such conditions. Protein microarrays have been used for AB profiling over the past decade but show some significant limitations which make them unsuitable for clinical applications. Alternative multiplexing platforms such as bead arrays were shown to provide a versatile tool for the confirmation and efficient analysis of high numbers of biological samples. Luminex' bead-based xMAP technology combines advantages such as multiplexing and lower demand for sample volume and at the same time overcomes the challenges of microarrays. It works faster, shows better antigen stability, is more reproducible, and allows the analysis of up to 500 analytes in one sample well. In this chapter we introduce our established workflow for the use of the xMAP technology for AB profiling including an overview of the method principle and protocols for the covalent immobilization of proteins to the MagPlex beads, confirmation of protein coupling, the execution of a multiplexed bead-based protein immunoassay, and subsequent data handling.


Assuntos
Antígenos , Soro , Testes Imunológicos , Autoanticorpos , Imunoensaio/métodos
5.
Methods Mol Biol ; 2628: 505-533, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36781804

RESUMO

Antigenic peptides are commonly used in serological test settings such as enzyme-linked immunosorbent assays (ELISA) to determine reactive antibodies (ABs) from serum or plasma samples. The use of synthetic peptides provides advantages like lower production effort and easier incorporation of specific chemical modifications compared to full-length antigenic proteins. Multiplexed antibody (AB) profiling methods such as microarray technologies enable the simultaneous identification of multiple novel biomarkers for the use in early disease diagnostics, vaccine development, or monitoring of immune responses. Despite various benefits they still show major limitations which can be overcome with bead-based assay technologies like the multi-analyte profiling (xMAP) technology developed by Luminex. In this chapter we introduce our established workflow for AB profiling with a multiplexed bead-based peptide immunoassay. The workflow is based on copper-catalyzed click chemistry to immobilize designed synthetic peptides onto uniquely color-coded paramagnetic beads in an orientation-specific manner. The individual peptide-coupled beads can be distinguished by their unique emission spectra during readout in the xMAP instrument and therefore allow testing of up to 500 different antigenic peptides in one multiplexed reaction. The multistep process described in this chapter is divided into separate sections for peptide design, coupling of functionalized peptides to MagPlex beads via click chemistry, confirmation of successful peptide immobilization, processing of serum or plasma samples, or preferably purified IgG thereof, with the multiplexed bead-based peptide immunoassay and subsequent data export and analysis.


Assuntos
Anticorpos , Soro , Imunoensaio/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Soro/química , Peptídeos
6.
Biotechniques ; 72(4): 134-142, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35234537

RESUMO

ELISA is the current standard for (auto)antibody diagnostics. Once established, ELISA protocols can be easily adapted for novel antigens; however, peptide-based protocols are rarely available. Herein the authors describe the results of a technical investigation of an indirect ELISA protocol using peptides conjugated onto a protein carrier based on click chemistry and immobilized in standard plastics. The authors compared this approach with the common biotin-avidin system and obtained a slightly improved limit of detection for purified IgG of 25-100 ng/well compared with 25-1000 ng/well. Reproducibility and stability of the methodological approach were conducted for further technical characterization. Indirect ELISA using immunoreactive peptides conjugated to bovine serum albumin offers a reliable method that is complementary to standard plastics and plate readers.


Assuntos
Química Click , Peptídeos , Biotina/química , Ensaio de Imunoadsorção Enzimática/métodos , Peptídeos/metabolismo , Plásticos , Reprodutibilidade dos Testes
7.
ACS Appl Mater Interfaces ; 13(23): 27645-27655, 2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34081862

RESUMO

A combined approach to signal enhancement in fluorescence affinity biosensors and assays is reported. It is based on the compaction of specifically captured target molecules at the sensor surface followed by optical probing with a tightly confined surface plasmon (SP) field. This concept is utilized by using a thermoresponsive hydrogel (HG) binding matrix that is prepared from a terpolymer derived from poly(N-isopropylacrylamide) (pNIPAAm) and attached to a metallic sensor surface. Epi-illumination fluorescence and SP-enhanced total internal reflection fluorescence readouts of affinity binding events are performed to spatially interrogate the fluorescent signal in the direction parallel and perpendicular to the sensor surface. The pNIPAAm-based HG binding matrix is arranged in arrays of sensing spots and employed for the specific detection of human IgG antibodies against the Epstein-Barr virus (EBV). The detection is performed in diluted human plasma or with isolated human IgG by using a set of peptide ligands mapping the epitope of the EBV nuclear antigen. Alkyne-terminated peptides were covalently coupled to the pNIPAAm-based HG carrying azide moieties. Importantly, using such low-molecular-weight ligands allowed preserving the thermoresponsive properties of the pNIPAAm-based architecture, which was not possible for amine coupling of regular antibodies that have a higher molecular weight.


Assuntos
Resinas Acrílicas/química , Técnicas Biossensoriais/métodos , Infecções por Vírus Epstein-Barr/diagnóstico , Antígenos Nucleares do Vírus Epstein-Barr/imunologia , Hidrogéis/química , Imunoglobulina G/análise , Fragmentos de Peptídeos/metabolismo , Infecções por Vírus Epstein-Barr/imunologia , Infecções por Vírus Epstein-Barr/metabolismo , Infecções por Vírus Epstein-Barr/virologia , Fluorescência , Herpesvirus Humano 4/imunologia , Herpesvirus Humano 4/isolamento & purificação , Humanos , Hidrogéis/metabolismo , Imunoglobulina G/imunologia , Fragmentos de Peptídeos/imunologia , Polímeros/química
8.
PLoS One ; 15(2): e0228615, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32050001

RESUMO

To date, no comprehensive analysis of autoantibodies in sera of patients with ulcerative colitis has been conducted. To analyze the spectrum of autoantibodies and to elucidate their role serum-IgG from UC patients (n = 49) and non-UC donors (n = 23) were screened by using a human protein microarray. Screening yielded a remarkable number of 697 differentially-reactive at the nominal 0·01 significance level (FDR<0·1) of the univariate test between the UC and the non-UC group. CD99 emerged as a biomarker to discriminate between both groups (p = 1e-04, AUC = 0·8). In addition, cytokines, chemokines and growth factors were analyzed by Olink's Proseek® Multiplex Inflammation-I 96×96 immuno-qPCR assay and 31 genes were significant at the nominal 0.05 level of the univariate test to discriminate between UC and non-UC donors. MCP-3, HGF and CXCL-9 were identified as the most significant markers to discriminate between UC patients with clinically active and inactive disease. Levels of CXCL10 (cor = 0.3; p = 0.02), CCL25 (cor = 0.25; p = 0.04) and CCL28 (cor = 0.3; p = 0.02) correlated positively with levels of anti CD99. To assess whether autoantibodies are detectable prior to diagnosis with UC, sera from nine donors at two different time points (T-early, median 21 months and T-late, median 6 months) were analyzed. 1201 features were identified with higher reactivity in samples at time points closer to clinical UC presentation. In vitro, additional challenge of peripheral mononuclear cells with CD99 did not activate CD4+ T cells but induced the secretion of IL-10 (-CD99: 20.21±20.25; +CD99: 130.20±89.55; mean ±sd; p = 0.015). To examine the effect of CD99 in vivo, inflammation and autoantibody levels were examined in NOD/ScidIL2Rγnull mice reconstituted with PBMC from UC donors (NSG-UC). Additional challenge with CD99 aggravated disease symptoms and pathological phenotype as indicated by the elevated clinical score (-CD99: 1·85 ± 1·94; +CD99: 4·25 ± 1·48) and histological score (-CD99: 2·16 ± 0·83; +CD99: 3·15 ± 1·16, p = 0·01). Furthermore, levels of anti-CD99 antibodies increased (Control: 398 ± 323; mean MFI ± sd; Ethanol + PBS: 358 ±316; Ethanol + CD99: 1363 ± 1336; Control versus Ethanol + CD99: p = 0.03). In a highly inflammatory environment, frequencies of pro-inflammatory M1 monocytes (CD14+ CD64+: unchallenged 8.09±4.72; challenged 14.2±8.62; p = 0.07; CD14+ CD1a+: unchallenged 16.29 ±6.97; challenged 43.81±14.4, p = 0.0003) increased and levels of autoantibodies in serum decreased in the NSG-UC mouse model. These results suggest that autoantibodies are potent biomarkers to discriminate between UC and non-UC and indicate risk to develop UC. In an inflammatory environment, auto-antibodies may promote the pathological phenotype by activating M1 monocytes in the NSG-UC animal model and also in patients with UC.


Assuntos
Autoanticorpos/sangue , Colite Ulcerativa/diagnóstico , Adulto , Idoso , Animais , Autoanticorpos/imunologia , Biomarcadores/sangue , Células Cultivadas , Colite Ulcerativa/sangue , Colite Ulcerativa/imunologia , Citocinas/sangue , Feminino , Humanos , Masculino , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Pessoa de Meia-Idade
9.
PLoS One ; 14(6): e0218456, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31220138

RESUMO

Saliva based diagnostics is a rapidly evolving field due to the large diagnostic potential and simple sample collection. Currently only few individual molecules were investigated for their diagnostic capabilities in saliva. A systematic comparison of IgG antibody profiles in saliva and plasma is still missing in scientific literature. Our hypothesis is that IgG profiles in plasma and saliva are highly similar for each individual. As a consequence, one could implement practically any plasma based IgG assay (classical serology) as saliva based assay. In other words, the IgG antibodies found in blood are also accessible from saliva. We confirm our hypothesis by comparing IgG reactivities towards protein and peptide antigens. We isolated saliva IgG with high purity and demonstrate that plasma IgG reactivities (classical serology) can be inferred from saliva. As a showcase we perform Hepatitis B virus antibody (plasma-)titer determination from saliva. Additionally we show that plasma and saliva IgG profiles of 20 individuals are highly similar for 256 peptide antigens and match (unsupervised) with high probabilities. Finally, we argue for generalisation to the complete IgG antibody profile. The presented findings could contribute greatly to the development of saliva based diagnostic methods of numerous antibody based tests.


Assuntos
Anticorpos Antivirais/isolamento & purificação , Hepatite B/sangue , Imunoglobulina G/sangue , Saliva/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Ensaio de Imunoadsorção Enzimática , Hepatite B/virologia , Vírus da Hepatite B/isolamento & purificação , Vírus da Hepatite B/patogenicidade , Humanos , Imunoglobulina G/imunologia
10.
Microarrays (Basel) ; 4(2): 162-87, 2015 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-27600218

RESUMO

New minimal invasive diagnostic methods for early detection of lung cancer are urgently needed. It is known that the immune system responds to tumors with production of tumor-autoantibodies. Protein microarrays are a suitable highly multiplexed platform for identification of autoantibody signatures against tumor-associated antigens (TAA). These microarrays can be probed using 0.1 mg immunoglobulin G (IgG), purified from 10 µL of plasma. We used a microarray comprising recombinant proteins derived from 15,417 cDNA clones for the screening of 100 lung cancer samples, including 25 samples of each main histological entity of lung cancer, and 100 controls. Since this number of samples cannot be processed at once, the resulting data showed non-biological variances due to "batch effects". Our aim was to evaluate quantile normalization, "distance-weighted discrimination" (DWD), and "ComBat" for their effectiveness in data pre-processing for elucidating diagnostic immune­signatures. "ComBat" data adjustment outperformed the other methods and allowed us to identify classifiers for all lung cancer cases versus controls and small-cell, squamous cell, large-cell, and adenocarcinoma of the lung with an accuracy of 85%, 94%, 96%, 92%, and 83% (sensitivity of 0.85, 0.92, 0.96, 0.88, 0.83; specificity of 0.85, 0.96, 0.96, 0.96, 0.83), respectively. These promising data would be the basis for further validation using targeted autoantibody tests.

11.
J Immunol Methods ; 418: 39-51, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25675867

RESUMO

UNLABELLED: Specimen collection method and quality insurance are pivotal in biomarker discovery. Pre-analytical variables concerning blood collection and sample handling might affect analytical results and should be standardised prior application. In this study, we examine pre-analytical characteristics of blood samples using protein microarray. The influences of 1) standby times until centrifugation (1 h, 4 h, 24 h and 48 h), 2) four blood collection methods, and 3) IgG purified from those samples on differentially reactive antigens between samples ("DIRAGs") were investigated. Spearman correlation analyses of intra-individual arrays demonstrated remarkable differences (0.75-0.98 vs. 0.5-0.75) of antibody reactivities within and between serum and plasma samples. Class comparison showed that reactive antigen profiles were best preserved using IgG purified samples of serum tubes without separation gel as after 24h 83% of the 1h baseline DIRAGs were re-found. Testing dilution series with protein microarrays and Luminex xMap® Technology, we found linear correlations (R(2) = 0.94-0.99) between IgG concentration and read-out when using purified IgG instead of serum. Therefore, we highly recommend standardising pre-analytics and proposing the use of purified IgG for autoantibody immune-profiling with protein microarrays to reduce potential unspecific binding of matrix proteins abundant in serum and plasma samples. SIGNIFICANCE: Although purified IgG cannot completely compensate the influence of pre-analytics, in highly parallel immune-profiling IgG enables reduction of unspecific effects, which occur when using serum or plasma for analysis on protein microarrays. Reproducibility problems due to pre-analytical processing of blood samples might explain discrepant results reported in various biomarker studies.


Assuntos
Métodos Analíticos de Preparação de Amostras , Biomarcadores/sangue , Coleta de Amostras Sanguíneas , Imunoglobulina G/isolamento & purificação , Análise Serial de Proteínas/métodos , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA