RESUMO
Radiation therapy is an effective treatment modality for a variety of cancers. Despite several advances in delivery techniques, its main drawback remains the deposition of dose in normal tissues which can result in toxicity. Common practices of evaluating toxicity, using questionnaires and grading systems, provide little underlying information beyond subjective scores, and this can limit further optimization of treatment strategies. Nuclear medicine imaging techniques can be utilised to directly measure regional baseline function and function loss from internal/external radiation therapy within normal tissues in an in vivo setting with high spatial resolution. This can be correlated with dose delivered by radiotherapy techniques to establish objective dose-effect relationships, and can also be used in the treatment planning step to spare normal tissues more efficiently. Toxicity in radionuclide therapy typically occurs due to undesired off-target uptake in normal tissues. Molecular imaging using diagnostic analogues of therapeutic radionuclides can be used to test various interventional protective strategies that can potentially reduce this normal tissue uptake without compromising tumour uptake. We provide an overview of the existing literature on these applications of nuclear medicine imaging in diverse normal tissue types utilising various tracers, and discuss its future potential.
Assuntos
Braquiterapia , Neoplasias , Medicina Nuclear , Diagnóstico por Imagem , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por ComputadorRESUMO
Redox conditions and organic matter control marine methylmercury (MeHg) production. The Black Sea is the world's largest and deepest anoxic basin and is thus ideal to study Hg species along the extended redox gradient. Here we present new dissolved Hg and MeHg data from the 2013 GEOTRACES MEDBlack cruise (GN04_leg2) that we integrated into a numerical 1-D model, to track the fate and dynamics of Hg and MeHg. Contrary to a previous study, our new data show highest MeHg concentrations in the permanently anoxic waters. Observed MeHg/Hg percentage (range 9-57%) in the anoxic waters is comparable to other subsurface maxima in oxic open-ocean waters. With the modeling we tested for various Hg methylation and demethylation scenarios along the redox gradient. The results show that Hg methylation must occur in the anoxic waters. The model was then used to simulate the time evolution (1850-2050) of Hg species in the Black Sea. Our findings quantify (1) inputs and outputs of HgT (~31 and ~28 kmol yr-1) and MeHgT (~5 and ~4 kmol yr-1) to the basin, (2) the extent of net demethylation occurring in oxic (~1 kmol yr-1) and suboxic water (~6 kmol yr-1), (3) and the net Hg methylation in the anoxic waters of the Black Sea (~11 kmol yr-1). The model was also used to estimate the amount of anthropogenic Hg (85-93%) in the Black Sea.
RESUMO
The objective of this study was to determine how clinicians make use of the modern multiplex PCR assays (MPAs) to manage patients hospitalized for community-acquired pneumonia (CAP). We studied the use of MPAs in 1648 patients hospitalized for CAP over a 3-year period at the moment of the setup of the new PCR assay. We observed that the use of MPAs for the identification of multiple respiratory pathogens marks a radical change in the investigation of CAP etiology. Surprisingly, the contribution of MPAs to the medical decision-making process varies drastically according to the units of care.
Assuntos
Tomada de Decisão Clínica/métodos , Reação em Cadeia da Polimerase Multiplex , Pneumonia/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Comunitárias Adquiridas/diagnóstico , Infecções Comunitárias Adquiridas/etiologia , Infecções Comunitárias Adquiridas/terapia , Estudos Transversais , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia/diagnóstico , Pneumonia/etiologia , Estudos Retrospectivos , Adulto JovemRESUMO
The objectives is to thoroughly analyze the pattern of failure and oncologic outcome in recurrent oropharyngeal cancer (OPC) after (chemo)radiotherapy and correlate the site of failure to the planned radiation dose. Between January 2010 and April 2014, 57 patients with recurrent OPC after (chemo)radiotherapy were analyzed. Endpoints were pattern of failure and overall survival (OS). Local (LF) and regional failure (RF) were classified as in-field [>50% within gross tumor volume (GTV)], marginal [<50% within GTV but >50% within clinical target volume (CTV)], or out-of-field (>50% outside CTV) recurrences. In the whole group, 70 recurrences were reported. Of the 31 LF, 29 (93.5%) were in-field and 2 (6.5%) were marginal. No out-field LF was reported. Of the 21 RF, 13 RF (62%) were in-field, 6 (28.5%) marginal, and 2 (9.5%) out-of-field recurrences. Forty-three percent of RF was developed in an electively treated neck level, and 2 of them were contralateral. OS at 2 years in recurrent HPV positive, compared to HPV-negative OPC, were 66 and 18%, respectively (p = 0.011). OS was also significantly better in patients that were salvage treatment which was possible (70 vs. 6%, p < 0.001). Median survival after distant failure was 3.6 months. The great majority of LFs were located within the GTV and 43% of RFs developed in an electively treated neck level. The currently used margins and dose recipe and the indication for bilateral nodal irradiation need to be reevaluated. OS was significantly better in recurrent HPV-positive OPC and in patients, where salvage treatment was possible.
Assuntos
Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/terapia , Recidiva Local de Neoplasia/etiologia , Neoplasias Orofaríngeas/patologia , Neoplasias Orofaríngeas/terapia , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/mortalidade , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/mortalidade , Neoplasias Orofaríngeas/mortalidade , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Terapia de Salvação , Falha de TratamentoRESUMO
BACKGROUND: Breast cancer screening, improved imaging and neoadjuvant systemic therapy (NST) have led to increased numbers of non-palpable tumours suitable for breast-conserving surgery (BCS). Accurate tumour localization is essential to achieve a complete resection in these patients. This study evaluated the role of radioactive seed localization (RSL) in improving breast- and axilla-conserving surgery in patients with breast cancer with or without NST. METHODS: Patients who underwent RSL between 2007 and 2014 were included. Learning curves were analysed by the rates of minimally involved (in situ/invasive tumour cells on a length of 0-4 mm on ink) and positive resection margins (over 4 mm on ink) after BCS, and the median resection volume over time. RESULTS: A total of 367 patients with in situ carcinomas and 199 with non-palpable invasive breast cancer underwent RSL before primary surgery. A further 697 patients had RSL before NST, of whom 206 also underwent RSL of a histologically verified axillary lymph node metastasis. BCS was performed in 93·2 and 87·9 per cent of patients undergoing primary surgery for in situ and invasive tumours respectively, and 57·5 per cent of those in the NST group. The rate of BCS with positive resection margins was low and stable over time in the three groups (9·1, 9·7 and 11·2 per cent respectively). The median resection volume decreased significantly with time in the invasive cancer and NST groups. CONCLUSION: In the present study of more than 1200 patients and 7 years of experience, RSL was shown to facilitate breast- and axilla-conserving surgery in a diverse patient population. There was a significant reduction in resection volume while maintaining low positive resection margin rates after BCS.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Radioisótopos do Iodo , Mastectomia Segmentar , Compostos Radiofarmacêuticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/cirurgia , Neoplasias da Mama/terapia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Ductal de Mama/terapia , Carcinoma Intraductal não Infiltrante/cirurgia , Carcinoma Intraductal não Infiltrante/terapia , Feminino , Humanos , Curva de Aprendizado , Modelos Lineares , Pessoa de Meia-Idade , Terapia Neoadjuvante , Cintilografia , Resultado do TratamentoRESUMO
PURPOSE: Radiotherapy is traditionally given in equally spaced weekday fractions. We hypothesize that heterogeneous interfraction intervals can increase radiosensitivity via reoxygenation. Through modeling, we investigate whether this minimizes local failures and toxicity for early-stage non-small cell lung cancer (NSCLC). METHODS: Previously, a tumor dose-response model based on resource competition and cell-cycle-dependent radiosensitivity accurately predicted local failure rates for early-stage NSCLC cohorts. Here, the model mathematically determined non-uniform inter-fraction intervals minimizing local failures at similar normal tissue toxicity risk, i.e., iso-BED3 (iso-NTCP) for fractionation schemes 18Gyx3, 12Gyx4, 10Gyx5, 7.5Gyx8, 5Gyx12, 4Gyx15. Next, we used these optimized schedules to reduce toxicity risk (BED3) while maintaining stable local failures (TCP). RESULTS: Optimal schedules consistently favored a "primer shot" fraction followed by a 2-week break, allowing tumor reoxygenation. Increasing or decreasing the assumed baseline hypoxia extended or shortened this optimal break by up to one week. Fraction sizes of 7.5 Gy and up required a single primer shot, while smaller fractions needed one or two extra fractions for full reoxygenation. The optimized schedules, versus consecutive weekday fractionation, predicted absolute LF reductions of 4.6%-7.4%, except for the already optimal LF rate seen for 18Gyx3. Primer shot schedules could also reduce BED3 at iso-TCP with the biggest improvements for the shortest schedules (94.6Gy reduction for 18Gyx3). CONCLUSION: A validated simulation model clearly supports non-standard "primer shot" fractionation, reducing the impact of hypoxia-induced radioresistance. A limitation of this study is that primer-shot fractionation is outside prior clinical experience and therefore will require clinical studies for definitive testing.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma de Pequenas Células do Pulmão , Humanos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Fracionamento da Dose de Radiação , HipóxiaRESUMO
HYPOTHESIS: Abrasive-blasted steel surfaces exhibit a complex, multi-substrate environment. Adsorption to contaminant substrates can reduce the amount of available corrosion inhibitor and decrease its efficiency. Knowledge of where inhibitors preferentially adsorb is required. EXPERIMENTS: The quantitative extent and strength of adsorption of the representative corrosion inhibitor benzotriazole (BTAH) from toluene to particular substrates is given, including corrections for solution self-association, and complemented by X-ray photoelectron spectroscopy (XPS), sum-frequency generation spectroscopy (SFG), and quartz crystal microbalance (QCM) measurements. FINDINGS: All substrates show adsorbed BTAH layers. Based on the adsorption strength, preferential adsorption is found to be in the order steel > iron oxide > calcium carbonate and garnet > silica - this is relevant when there is limited BTAH. However, with ample BTAH, the amounts adsorbed in the plateau regions of the isotherm are more relevant and the order is calcium carbonate and silica > iron oxide > garnet > steel. Although the contaminant substrates deplete the BTAH concentration, the steel should still have a complete monolayer of BTAH inhibitor. This work is part of a larger initiative developing novel methods of corrosion inhibitor delivery via the blasting process, to prevent corrosion between blasting and repainting.
RESUMO
Ombrotrophic peatlands are fed uniquely by atmospheric inputs and therefore have much potential as temporal archives of atmospheric microplastic (MP) deposition, yet the recovery and detection of MP within an almost purely organic matrix is challenging. This study presents a novel peat digestion protocol using sodium hypochlorite (NaClO) as a reagent for biogenic matrix removal. NaClO is more efficient than hydrogen peroxide (H2O2). By using purged air-assisted digestion, NaClO (50 vol%) reached 99% matrix digestion compared with 28% and 75% by H2O2 (30 vol%) and Fenton's reagent, respectively. At a concentration of 50 vol% NaClO did however chemically disintegrate small amounts (<10 mass %) of polyethylene terephthalate (PET) and polyamide (PA) fragments in the millimeter size range. Observation of PA6 in natural peat samples, while not found in the procedural blanks, questions whether PA is fully disintegrated by NaClO. The protocol was applied to three commercial sphagnum moss test samples, in which MP particles in the range of 0.8-65.4 µm were detected by Raman microspectroscopy. The MP mass% was determined at 0.012% corresponding to 129 thousand MP particles/g, of which 62% were smaller than 5 µm and 80% were smaller than 10 µm, yet were accountable for only 0.4% (500 ng) and 3.2% (4 µg) of the total mass of MP, respectively. These findings underline the importance of the identification of particles Ø < 5 µm when investigating atmospheric MP deposition. The MP counts were corrected for MP recovery loss and procedural blank contamination. MP spike recovery following the full protocol was estimated at 60%. The protocol offers an efficient way of isolating and pre-concentrating most aerosol sized MPs in large quantities of refractory vegetal matrices and enables the automated µRaman scanning of thousands of particles at a spatial resolution on the order of 1 µm.
Assuntos
Microplásticos , Poluentes Químicos da Água , Microplásticos/química , Plásticos , Peróxido de Hidrogênio , Poluentes Químicos da Água/análise , Monitoramento Ambiental , Nylons , SoloRESUMO
PURPOSE: Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was to evaluate an analysis of variance (ANOVA) based validation to account for such observer variation. METHODS: Weekly cone beam CTs (CBCTs) of ten head and neck cancer patients undergoing five weeks of radiotherapy were used. An expert identified 23 anatomical features (landmarks) on the planning CT. The landmarks were automatically propagated to the CBCT using multiregion-of-interest (mROI) registration. Additionally, two human observers independently localized these landmarks on the CBCTs. Subsequently, ANOVA was used to compute the variance of each observer on the pairwise distance (PWD). RESULTS: ANOVA based analysis demonstrated that a classical DTA approach underestimated the precision for the mROI due to human observer variation by about 25%. The systematic error (accuracy) of mROI ranged from 0.13 to 0.17 mm; the variability (1 SD) (precision) ranged from 1.3 to 1.5 mm demonstrating that its performance is dominated by the precision. CONCLUSIONS: The PWD-ANOVA method accounts for human observer variation allowing a better estimation of the of DIR errors.
Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Análise de Variância , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
PURPOSE: Image-guided stereotactic body radiation therapy (SBRT) is an important local treatment for liver metastases. MRI-guidance enables direct tumor visualization, eliminating fiducial marker implantation. The purpose of this study was to test technical feasibility of our 4D-MRI guided liver SBRT workflow. Additionally, intra-fraction target motion and consequent target-coverage were studied. MATERIALS & METHODS: Patients with liver metastases were included in this sub-study of the prospective UMBRELLA-II clinical trial. Patients received mid-position (midP) SBRT. The daily adapt-to-position workflow included localization, verification and intra-fraction tumor midP monitoring using 4D-MRI. Technical feasibility was established based on persistence of the treatment protocol, treatment time ≤1 h, no geographical miss and no unexpected acute toxicity grade >3. All 4D-MRIs were registered to the planning midP-CT and tumor midP and amplitude were calculated. Additionally, delivered target dose was accumulated incorporating the 4D-MRI intra-fraction tumor motion and evaluated with Monte-Carlo error simulations. RESULTS: 20 patients with liver metastases were included and treated with 4D-MRI guided SBRT. Feasibility criteria were met in all-but-one patient. No grade ≥3 acute toxicity was observed. Group mean (M), systematic and random midP-drifts were 2.4 mm, 2.6 mm and 3.1 mm in CC-direction. 4D-MRI tumor CC-amplitudes were reduced compared to the simulation 4D-CT (M = -1.9 mm) and decreased during treatment (M = -1.4 mm). Dose accumulation showed adequate target-coverage on a population level. CONCLUSION: We successfully demonstrated technical feasibility of 4D-MRI guided SBRT in a cohort of 20 patients with liver metastases. However, substantial midposition drifts occurred which stress the need for intra-fraction motion management strategies to further increase the precision of treatment delivery.
Assuntos
Neoplasias Hepáticas , Radiocirurgia , Estudos de Viabilidade , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética , Estudos Prospectivos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodosRESUMO
The emerging threat of atmospheric microplastic pollution has prompted researchers to study areas previously considered beyond the reach of plastic. Investigating the range of atmospheric microplastic transport is key to understanding the global extent of this problem. While atmospheric microplastics have been discovered in the planetary boundary layer, their occurrence in the free troposphere is relatively unexplored. Confronting this is important because their presence in the free troposphere would facilitate transport over greater distances and thus the potential to reach more distal and remote parts of the planet. Here we show evidence of 0.09-0.66 microplastics particles/m3 over 4 summer months from the Pic du Midi Observatory at 2877 meters above sea level. These results exhibit true free tropospheric transport of microplastic, and high altitude microplastic particles <50 µm (aerodynamic diameter). Analysis of air/particle history modelling shows intercontinental and trans-oceanic transport of microplastics illustrating the potential for global aerosol microplastic transport.
RESUMO
RATIONALE: PSMA-directed therapy for metastatic prostate cancer is gaining adoption as a treatment option. However, accumulation of 177Lu/225Ac-PSMA in the salivary glands remains a problem, with risk of dose-limiting xerostomia and potentially severe effect on the quality of life. Gustatory stimulation is an approach that has commonly been used in radioactive iodine therapy to reduce accumulation in the salivary glands. However, based on theoretical differences in biodistribution, it was hypothesized that this could potentially lead to adverse increased toxicity for PSMA-ligand therapy. The primary objective of this work was to determine if gustatory stimulation by eating an assortment of sweet/fatty/acidic foods during the biodistribution phase of [18F]DCFPyl could result in a clinically relevant (> 30%) change in the uptake of the tracer in the salivary glands. METHODS: 10 patients who already received a whole-body [18F]DCFPyl PET/CT scan for evaluation of prostate cancer, underwent a repeat (intervention) PET/CT scan within a month of the first (control) scan. During the intervention scan, patients chose from an assortment of sweet/fatty/acidic foods, which they then chewed and swallowed for a period of time starting 1 min before tracer administration to 10 min thereafter. Data from both scans were analyzed by placing VOIs on the major salivary glands and segmenting them using relative thresholds. RESULTS: A slight increase in PSMA uptake in the parotid glands was observed on the intervention scan when compared to the baseline scan (+ 7.1% SULmean and + 9.2% SULmax, p < 0.05). No significant difference in PSMA uptake in the submandibular glands was seen. CONCLUSIONS: Eating only slightly increases uptake of [18F]DCFPyl in the parotid glands. We nonetheless recommend refraining from gustatory stimulation during the administration and early biodistribution phase of radionuclide therapy with PSMA-ligands to reduce the risk of avoidable additional toxicity.
RESUMO
OBJECTIVE: Fluorescence-guided resections performed using 5-aminolevulinic acid (5-ALA) have been studied extensively using the BLUE400 system. The authors introduce a triple-light-emitting diode (LED) headlight/loupe device for visualizing fluorescence, and compare this to the BLUE400 gold standard in order to assure similar and not more or less sensitive protoporphyrin-IX visualization. METHODS: The authors defined the spectral requirements for a triple-LED headlight/loupe device for reproducing the xenon-based BLUE400 module. The system consisted of a white LED (normal surgery), a 409-nm LED for excitation, a 450-nm LED for background illumination, and appropriate observation filters. The prototype's excitation and emission spectra, illumination and detection intensities, and spot homogeneity were determined. The authors further performed a prospectively randomized and blinded study for fluorescence assessments of fresh, marginal, fluorescing and nonfluorescing tumor samples comparing the LED/loupe device with BLUE400 in patients with malignant glioma treated with 20 mg/kg body weight 5-ALA. Tumor samples were immediately assessed in turn, both with a Kinevo and with a novel triple-LED/loupe device by different surgeons. RESULTS: Seven triple-LED/loupe devices were analyzed. Illumination intensities in the 409- and 450-nm range were comparable to BLUE400, with high spot homogeneity. Fluorescence intensities measured distally to microscope oculars/loupes were 9.9-fold higher with the loupe device. For validation 26 patients with malignant gliomas with 240 biopsies were analyzed. With BLUE400 results as the reference, sensitivity for reproducing fluorescence findings was 100%, specificity was 95%, positive predictive value was 98%, negative predictive value was 100%, and accuracy was 95%. This study reached its primary aim, with agreement in 226 of 240 (94.2%, 95% CI 0.904-0.968). CONCLUSIONS: The authors observed only minor differences regarding spectra and illumination intensities during evaluation. Fluorescence intensities available to surgeons were 9.9-fold higher with the loupe device. Importantly, the independent perception of fluorescence achieved using the new system and BLUE400 was statistically equivalent. The authors believe the triple-LED/loupe device to be a useful and safe option for surgeons who prefer loupes to the microscope for resections in appropriate patients.
RESUMO
RATIONALE: Salivary glands are highly perfused and express the prostate-specific membrane antigen (PSMA) receptor as well as the sodium-iodide symporter. As a consequence, treatment with 177Lu/225Ac-PSMA for prostate cancer or 131I for thyroid cancer leads to a high radiation dose in the salivary glands, and patients can be confronted with persistent xerostomia and reduced quality of life. Salivation can be inhibited using an antimuscarinic pharmaceutical, such as glycopyrronium bromide (GPB), which may also reduce perfusion. The primary objective of this work was to determine if inhibition with GPB could provide a considerable (> 30%) reduction in the accumulation of administered 123I or 68Ga-PSMA-11 in salivary glands. METHODS: Ten patients who already received a whole-body 68Ga-PSMA-11 PET/CT scan for (re)staging of prostate cancer underwent a repeat PET/CT scan with tracer administration at 90 min after intravenous injection of 0.2 mg GPB. Four patients in follow-up after thyroid cancer, who had been treated with one round of ablative 131I therapy with curative intent and had no signs of recurrence, received 123I planar scintigraphy at 4 h after tracer administration without GPB and a repeated scan at least one week later, with tracer administration at 30 min after intramuscular injection of 0.4 mg GPB. Tracer uptake in the salivary glands was quantified on PET and scintigraphy, respectively, and values with and without GPB were compared. RESULTS: No significant difference in PSMA uptake in the salivary glands was seen without or with GPB (Mean SULmean parotid glands control 5.57, intervention 5.72, p = 0.50. Mean SULmean submandibular glands control 6.25, intervention 5.89, p = 0.12). Three out of 4 patients showed increased 123I uptake in the salivary glands after GPB (Mean counts per pixel control 8.60, intervention 11.46). CONCLUSION: Muscarinic inhibition of salivation with GPB did not significantly reduce the uptake of PSMA-ligands or radioiodine in salivary glands, and can be dismissed as a potential strategy to reduce toxicity from radionuclide therapies.
RESUMO
The potential for detrimental incidents and the ever increasing complexity of patient treatments emphasize the need for accurate dosimetric verification in radiotherapy. For this reason, all curative treatments are verified, either pretreatment or in vivo, by electronic portal imaging device (EPID) dosimetry in the Radiation Oncology Department of The Netherlands Cancer Institute-Antoni van Leeuwenhoek hospital, Amsterdam, The Netherlands. Since the clinical introduction of the method in January 2005 until August 2009, treatment plans of 4337 patients have been verified. Among these plans, 17 serious errors were detected that led to intervention. Due to their origin, nine of these errors would not have been detected with pretreatment verification. The method is illustrated in detail by the case of a plan transfer error detected in a 5 x 5 Gy intensity-modulated radiotherapy (IMRT) rectum treatment. The EPID reconstructed dose at the isocenter was 6.3% below the planned value. Investigation of the plan transfer chain revealed that due to a network transfer error, the plan was corrupted. 3D analysis of the acquired EPID data revealed serious underdosage of the planning target volume: On average 11.6%, locally up to 20%. This report shows the importance of in vivo (EPID) dosimetry for all treatment plans as well as the ability of the method to assess the dosimetric impact of deviations found.
Assuntos
Algoritmos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Ecrans Intensificadores para Raios X , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Heavy metal pollution in fine particulate matter (PM2.5) is a serious environmental and health concern in China, particularly during winter. Here, we detected 40 elements in 24 h integrated daily PM2.5 samples collected in January 2014 from three typical Chinese metropolises (Beijing, Changchun, and Chengdu) to reflect elemental spatial variations, local sources, and regional transport. The measured elemental concentrations in Changchun were 11.1% and 48.4% higher than those in Beijing and Chengdu, respectively. Thus, PM2.5 from Changchun exhibited high levels and diversity in the elemental profile (characterized by high concentrations of industrial emission elemental markers). The results of elemental ratios and Pb isotopes proved that, except for a coal combustion source, vehicular emissions contributed more to PM2.5 heavy metals in Beijing than in the other two cities; Changchun PM2.5 elements received large contributions from industrial sources, including iron and steel manufacturing, and automobile industry. Moreover, crustal dust from long-range transport of regional air masses from the northwest regions of China played a crucial role in determining elemental levels in Beijing and Changchun, accounting for more than 50% of source intensity. However, a specific dominant source was not determined in Chengdu; the contribution of anthropogenic dust, mainly from construction activities, needs to be paid attention in Chengdu eastern area. This study contributed to enhancing our understanding of elemental spatial distribution characteristics and sources and to setting more judicious standards and strategies for PM2.5 bound heavy metals in China.
Assuntos
Poluentes Atmosféricos , Chumbo , Pequim , China , Cidades , Poeira , Monitoramento Ambiental , Isótopos , Material Particulado , Estações do AnoRESUMO
Setup and range uncertainties compromise radiotherapy plan robustness. We introduce a method to evaluate the clinical effect of these uncertainties on the population using tumor control probability (TCP) and normal tissue complication probability (NTCP) models. Eighteen oropharyngeal cancer patients treated with curative intent were retrospectively included. Both photon (VMAT) and proton (IMPT) plans were created using a planning target volume as planning objective. Plans were recalculated for uncertainty scenarios: two for range over/undershoot (IMPT) or CT-density scaling (VMAT), six for shifts. An average shift scenario ([Formula: see text]) was calculated to assess random errors. Dose differences between nominal and scenarios were translated to TCP (2 models) and NTCP (15 models). A weighted average (W_Avg) of the TCP\NTCP based on Gaussian distribution over the variance scenarios was calculated to assess the clinical effect of systematic errors on the population. TCP/NTCP uncertainties were larger in IMPT compared to VMAT. Although individual perturbations showed risks of plan deterioration, the [Formula: see text] scenario did not show a substantial decrease in any of the TCP endpoints suggesting evaluated plans in this cohort were robust for random errors. Evaluation of the W_Avg scenario to assess systematic errors showed in VMAT no substantial decrease in TCP endpoints and in IMPT a limited decrease. In IMPT, the W_Avg scenario had a mean TCP loss of 0%-2% depending on plan type and primary or nodal control. The W_Avg for NTCP endpoints was around 0%, except for mandible necrosis in IMPT (W_Avg: 3%). The estimated population impact of setup and range uncertainties on TCP/NTCP following VMAT or IMPT of oropharyngeal cancer patients was small for both treatment modalities. The use of TCP/NTCP models allows for clinical interpretation of the population effect and could be considered for incorporation in robust evaluation methods. Highlights: - TCP/NTCP models allow for a clinical evaluation of uncertainty scenarios. - For this cohort, in silico-PTV based IMPT plans and VMAT plans were robust for random setup errors. - Effect of systematic errors on the population was limited: mean TCP loss was 0%-2%.
Assuntos
Neoplasias Orofaríngeas/radioterapia , Terapia com Prótons/efeitos adversos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Incerteza , Algoritmos , Humanos , Modelos Estatísticos , Distribuição Normal , Órgãos em Risco/efeitos da radiação , Probabilidade , Dosagem Radioterapêutica , Estudos RetrospectivosRESUMO
BACKGROUND & PURPOSE: To propose a novel mid-position (midP) workflow for MRI-guided liver SBRT and provide a validation of the required midP-MRI generation and registration steps. MATERIALS & METHODS: The first step of the midP workflow is the generation of a simulation midP-MRI from a 4D-MRI scan using deformable image registration. Next, a planning midP-CT is warped to the midP-MRI to enable planning in the midP-MRI anatomy. For daily MRI-guidance, three different registration methods to the simulation midP-MRI are proposed; (1) 4D rigid registration of all phases of the daily 4D-MRI, (2) 3D rigid registration of the daily midP-MRI, and (3) 3D deformable registration of the daily midP-MRI. The midP-MRI image quality was assessed with respect to 4D-MRI acquisition time, which is related to over-sampling of the data acquisition (i.e. number of dynamics). The deformable registration precision for the midP-MRI generation was validated using the distance discordance metric (DDM). The deformable CT-MRI and daily MRI-MRI registration accuracies were quantified using the 'full circle method'. RESULTS: The DDM was 1.5â¯mm (median) within the liver, independent of the number of dynamics. The root-mean-squared difference between midP-MRIs based on 10 and 60 dynamics was only 5.2%. The full circle CT-MRI deformable registration error had a median 3D vector length of 1.8â¯mm in the liver. The daily MRI-MRI registration error was submillimeter for all three evaluated methods. CONCLUSION: The feasibility of an MRI-guided mid-position workflow for liver SBRT is supported by the demonstrated high precision of all image processing and registration steps.
Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imagem por Ressonância Magnética Intervencionista/métodos , Radiocirurgia/métodos , Algoritmos , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Reprodutibilidade dos TestesRESUMO
BACKGROUND AND PURPOSE: Preclinical models are much needed to assess the effect of novel radio-sensitizers or mitigators on radiation dose limiting lung toxicity. Albeit showing radiation-induced lung pathologies, current mouse models lack the sensitivity to do so. Using micro image-guided radiotherapy (µIGRT) techniques, we aimed to establish murine models which enable the sensitive detection of lung damage aggravation and characterized functional, radiological and histological responses. MATERIALS AND METHODS: Right lungs of C57Bl/6J mice were irradiated using µIGRT with doses from 15 to 27â¯Gy and with 21â¯Gy and cisplatin as a radio-sensitizer in a second study. Mice were sacrificed for histological and pathological assessment at different time-points post-IR. Lung density was determined using the integrated micro cone-beam CT (µCBCT). Lung function was measured by double-chamber-plethysmography. RESULTS: µIGRT resulted in accurate deposition of the radiation dose in the right lung only as determined by É£H2AX staining. Lung fibrosis was confirmed by pathological assessments and increased significantly at 21â¯Gy as determined by automated quantification of histochemical analyses. Lung function was affected in a dose-dependent manner. µCBCT-determined lung densities increased significantly over time in the irradiated lungs and showed a strong radiation dose-dependence. Importantly, the µCBCT analyses allowed the detection of additional lung damage caused by 3â¯Gy dose increments or by the combination with cisplatin. CONCLUSION: µCBCT after right lung µIGRT enables the sensitive detection of effects inflicted by relative small dose increments or radio-sensitizers. Our preclinical model therefore facilitates the determination of lung damage exacerbation for the safety assessment of novel RT-drug combinations.
Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Lesão Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Lesões por Radiação/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Fracionamento da Dose de Radiação , Lesão Pulmonar/etiologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fibrose PulmonarRESUMO
PURPOSE: lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. METHODS AND MATERIALS: 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. RESULTS: Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods < 0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of "shape differences" was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. CONCLUSIONS: We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.