Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Lancet ; 385(9987): 2585-91, 2015 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-25888085

RESUMO

BACKGROUND: Orthotopic heart transplantation is the gold-standard long-term treatment for medically refractive end-stage heart failure. However, suitable cardiac donors are scarce. Although donation after circulatory death has been used for kidney, liver, and lung transplantation, it is not used for heart transplantation. We report a case series of heart transplantations from donors after circulatory death. METHODS: The recipients were patients at St Vincent's Hospital, Sydney, Australia. They received Maastricht category III controlled hearts donated after circulatory death from people younger than 40 years and with a maximum warm ischaemic time of 30 min. We retrieved four hearts through initial myocardial protection with supplemented cardioplegia and transferred to an Organ Care System (Transmedics) for preservation, resuscitation, and transportation to the recipient hospital. FINDINGS: Three recipients (two men, one woman; mean age 52 years) with low transpulmonary gradients (<8 mm Hg) and without previous cardiac surgery received the transplants. Donor heart warm ischaemic times were 28 min, 25 min, and 22 min, with ex-vivo Organ Care System perfusion times of 257 min, 260 min, and 245 min. Arteriovenous lactate values at the start of perfusion were 8·3-8·1 mmol/L for patient 1, 6·79-6·48 mmol/L for patient 2, and 7·6-7·4 mmol/L for patient 3. End of perfusion lactate values were 3·6-3·6 mmol/L, 2·8-2·3 mmol/L, and 2·69-2·54 mmol/L, respectively, showing favourable lactate uptake. Two patients needed temporary mechanical support. All three recipients had normal cardiac function within a week of transplantation and are making a good recovery at 176, 91, and 77 days after transplantation. INTERPRETATION: Strict limitations on donor eligibility, optimised myocardial protection, and use of a portable ex-vivo organ perfusion platform can enable successful, distantly procured orthotopic transplantation of hearts donated after circulatory death. FUNDING: NHMRC, John T Reid Charitable Trust, EVOS Trust Fund, Harry Windsor Trust Fund.


Assuntos
Displasia Arritmogênica Ventricular Direita/terapia , Cardiomiopatia Dilatada/terapia , Transplante de Coração/métodos , Miocardite/terapia , Preservação de Órgãos/métodos , Doadores de Tecidos/classificação , Obtenção de Tecidos e Órgãos/métodos , Adulto , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Biópsia , Cardiomiopatia Dilatada/fisiopatologia , Feminino , Parada Cardíaca Induzida , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Choque/patologia , Resultado do Tratamento , Viroses/terapia , Isquemia Quente
2.
Heart Lung Circ ; 21(4): 218-20, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22296942

RESUMO

Extracorporeal membrane oxygenation is an established treatment for acute respiratory failure, or low cardiac output syndrome. This can be veno-venous, in which de-oxygenated blood is drained from the venous system and oxygenated before being returned to the venous system, and veno-arterial where the re-oxygenated venous blood is returned to the arterial system. Haemorrhage, sepsis and thrombo-embolism are common and potentially lethal complications. Left ventricular assist devices are a continually evolving technology, that may be used as a bridge to transplantation or destination therapy in end-stage cardiac failure. The VentrAssist™ left ventricular assist device is a small implantable, continuous flow centrifugal pump, that is controlled and powered by a percutaneous lead. However, in these patients, right heart failure may present as an acute event following weaning from cardiopulmonary bypass (CPB), or post-operatively in the intensive care unit. Patients who do not respond to inotropes and pulmonary vasodilators may need a right ventricular assist device (RVAD). We report a successful case of right heart assist extra corporeal membrane oxygenation used as temporary right heart support in combination with a VentrAssist™ left ventricular assist device. The use of right heart assist extra corporeal membrane oxygenation to help a failing right heart during left ventricular assist device placement is not new, however, our technique describes a novel method of cannulation of the femoral vein and pulmonary trunk via a tunnelled vascular tube graft, which allows the chest to be closed whilst on right heart support, and decannulation to proceed without resternotomy. This technique has also been used successfully subsequent to this.


Assuntos
Cateterismo/métodos , Oxigenação por Membrana Extracorpórea , Artéria Femoral , Disfunção Ventricular Direita/terapia , Adolescente , Feminino , Coração Auxiliar , Humanos , Implantação de Prótese , Disfunção Ventricular Esquerda/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA