Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
MAGMA ; 36(3): 419-426, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35986790

RESUMO

OBJECTIVE: Speech production MRI benefits from lower magnetic fields due to reduced off-resonance effects at air-tissue interfaces and from the use of dedicated receiver coils due to higher SNR and parallel imaging capability. Here we present a custom designed upper airway coil for 1H imaging at 0.55 Tesla and evaluate its performance in comparison with a vendor-provided prototype 16-channel head/neck coil. MATERIALS AND METHODS: Four adult volunteers were scanned with both custom speech and prototype head-neck coils. We evaluated SNR gains of each of the coils over eleven upper airway volumes-of-interest measured relative to the integrated body coil. We evaluated parallel imaging performance of both coils by computing g-factors for SENSE reconstruction of uniform and variable density Cartesian sampling schemes with R = 2, 3, and 4. RESULTS: The dedicated coil shows approximately 3.5-fold SNR efficiency compared to the head-neck coil. For R = 2 and 3, both uniform and variable density samplings have g-factor values below 1.1 in the upper airway region. For R = 4, g-factor values are higher for both trajectories. DISCUSSION: The dedicated coil configuration allows for a significant SNR gain over the head-neck coil in the articulators. This, along with favorable g values, makes the coil useful in speech production MRI.


Assuntos
Imageamento por Ressonância Magnética , Fala , Adulto , Humanos , Razão Sinal-Ruído , Imageamento por Ressonância Magnética/métodos , Cabeça , Voluntários , Imagens de Fantasmas
2.
BMC Oral Health ; 23(1): 366, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37280604

RESUMO

BACKGROUND: Sublingual varices (SV) and their predictive potential for other clinical parameters is a much studied topic in oral medicine. SVs have been well studied as predictive markers for many common diseases such as arterial hypertension, cardiovascular disease, smoking, type 2 diabetes mellitus and age. Despite many prevalence studies, it is still unclear how the reliability of SV inspection affects its predictive power. The aim of this study was to quantify the inspection reliability of SV. METHODS: In a diagnostic study, the clinical inspection of 78 patients by 23 clinicians was examined for the diagnosis of SV. Digital images of the underside of the tongue were taken from each patient. The physicians were then asked to rate them for the presence of sublingual varices (0/1) in an online inspection experiment. Statistical analysis for inter-item and inter-rater reliability was performed in a τ-equivalent measurement model with Cronbach's [Formula: see text] and Fleiss κ. RESULTS: The interrater reliability for sublingual varices was relatively low with κ = 0.397. The internal consistency of image findings for SV was relatively high with α≈ 0.937. This shows that although SV inspection is possible in principle, it has a low reliability R. This means that the inspection finding (0/1) of individual images often cannot be reproduced stably. Therefore, SV inspection is a difficult task of clinical investigation. The reliability R of SV inspection also limits the maximum linear correlation [Formula: see text] of SV with an arbitrary other parameter Y. The reliability of SV inspection R = 0.847 limits the maximum correlation to [Formula: see text] (SV, Y) = 0,920-a 100% correlation was a priori not achievable in our sample. To overcome the problem of low reliability in SV inspection, we propose the RA (relative area) score as a continuous classification system for SV, which normalises the area of visible sublingual veins to the square of the length of the tongue, providing a dimensionless measure of SV. CONCLUSIONS: The reliability of the SV inspection is relatively low. This limits the maximum possible correlation of SV with other (clinical) parameters. SV inspection reliability is an important indicator for the quality of SV as a predictive marker. This should be taken into account when interpreting previous studies on SV and has implications for future studies. The RA score could help to objectify the SV examination and thus increase its reliability.


Assuntos
Diabetes Mellitus Tipo 2 , Hipertensão , Varizes , Humanos , Reprodutibilidade dos Testes , Varizes/diagnóstico , Língua/irrigação sanguínea
3.
J Evid Based Dent Pract ; 23(1S): 101794, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36707170

RESUMO

BACKGROUND: When dental patients seek care, treatments are not always successful,that is patients' oral health problems are not always eliminated or substantially reduced. Identifying these patients (treatment non-responders) is essential for clinical decision-making. Group-based trajectory modeling (GBTM) is rarely used in dentistry, but a promising statistical technique to identify non-responders in particular and clinical distinct patient groups in general in longitudinal data sets. AIM: Using group-based trajectory modeling, this study aimed to demonstrate how to identify oral health-related quality of life (OHRQoL) treatment response patterns by the example of patients with a shortened dental arch (SDA). METHODS: This paper is a secondary data analysis of a randomized controlled clinical trial. In this trial SDA patients received partial removable dental prostheses replacing missing teeth up to the first molars (N = 79) either or the dental arch ended with the second premolar that was present or replaced by a cantilever fixed dental prosthesis (N = 71). Up to ten follow-up examinations (1-2, 6, 12, 24, 36, 48, 60, 96, 120, and 180 months post-treatment) continued for 15 years. The outcome OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP). Exploratory GBTM was performed to identify treatment response patterns. RESULTS: Two response patterns could be identified - "responders" and "non-responders." Responders' OHRQoL improved substantially and stayed primarily stable over the 15 years. Non-responders' OHRQoL did not improve considerably over time or worsened. While the SDA treatments were not related to the 2 response patterns, higher levels of functional, pain-related, psychological impairment in particular, and severely impaired OHRQoL in general predicted a non-responding OHRQoL pattern after treatment. Supplementary, a 3 pattern approach has been evaluated. CONCLUSIONS: Clustering patients according to certain longitudinal characteristics after treatment is generally important, but specifically identifying treatment in non-responders is central. With the increasing availability of OHRQoL data in clinical research and regular patient care, GBTM has become a powerful tool to investigate which dental treatment works for which patients.


Assuntos
Prótese Parcial Removível , Qualidade de Vida , Humanos , Prótese Parcial Removível/psicologia , Arco Dental , Saúde Bucal , Dente Molar
4.
Clin Oral Investig ; 26(4): 3707-3719, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34935067

RESUMO

OBJECTIVES: The aim of the study was to determine differences between Locator and CM LOC attachment systems regarding patient satisfaction and wear of the abutments and their inserts. Plaque accumulation onto the polyetherketoneketone (PEKK) framework and polymethylmethacrylate (PMMA) was investigated for the implant-supported overdentures. METHODS: Seventeen edentulous patients were randomised to receive either Locator or CM LOC system for the first year. The total number of implants was 53. After the randomisation, 25 implants received Locator system, and 28 implants received CM LOC system in the first year. After a period of 12 months, the attachment system was exchanged from either Locator to CM LOC or vice versa. Oral Health Impact Profile (OHIP-14) questionnaires were used to evaluate patient satisfaction, chewing comfort, and pressure lesions. Prosthesis hygiene on the PMMA and PEKK surfaces was evaluated by using Stark plaque index. After the exchange of the abutments, they were stored until the end of the 24 months, and the surface wear of the abutments was analysed using a scanning electron microscope. RESULTS: Three patients (10 implants) died shortly before the end of the first year. Two patients (7 implants) received only Locator system since CM LOC was not indictable for their implant system. Patient's satisfaction was increased when the attachment system was changed from Locator to CM LOC after 12 months of wearing time. Chewing ability and comfort were increased when the attachment system was changed from CM LOC to Locator after 12-month wearing time. There was no influence of the change of the attachment system on pressure lesions. The observed plaque accumulation was higher on the PMMA than on the PEKK surface. For the 8 investigated Locator abutments, the wear was within low and middle level. For the 28 investigated CM LOC abutments, the wear was within middle and high level for the terminal implants and between low and middle for the central implants (for patients who received 4 implants). CONCLUSIONS: Patient's satisfaction and wearing comfort can be improved with implant-supported overdentures with CM LOC abutments in comparison to Locator. There was no clear difference between both attachment systems concerning the chewing ability of the patients. Plaque accumulation was observed on both attachment systems in different areas. Plaque accumulation on PEKK surface was less than on PMMA surface. CLINICAL RELEVANCE: The CM LOC attachment system offers stable and comfortable wearing conditions for implant-supported overdentures. The use of PEKK as a framework material could reduce the incidence of pressure lesions.


Assuntos
Implantes Dentários , Arcada Edêntula , Benzofenonas , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Revestimento de Dentadura , Humanos , Mandíbula , Mucosa , Projetos Piloto , Polímeros
5.
J Mater Sci Mater Med ; 32(1): 4, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33471194

RESUMO

Adhesive resin-cements are increasingly used in modern dentistry. Nevertheless, released substances from resin materials have been shown to cause cellular toxic effects. Disc-shaped specimens from 12 different resin cements and one conventional zinc phosphate cement were prepared and used for direct stimulation of five different human cell lines via transwell cell culture system or in an indirect way using conditioned cell culture media. Cytotoxicity was determined using LDH and BCA assays. All tested cements led to a decrease of cell viability but to a distinct extent depending on cell type, luting material, and cytotoxicity assay. In general, cements exhibited a more pronounced cytotoxicity in direct stimulation experiments compared to stimulations using conditioned media. Interestingly, the conventional zinc phosphate cement showed the lowest impact on cell viability. On cellular level, highest cytotoxic effects were detected in osteoblastic cell lines. All resin cements reduced cell viability of human cells with significant differences depending on cell type and cement material. Especially, osteoblastic cells demonstrated a tremendous increase of cytotoxicity after cement exposure. Although the results of this in vitro study cannot be transferred directly to a clinical setting, it shows that eluted substances from resin cements may disturb osteoblastic homeostasis that in turn could lead to conditions favoring peri-implant bone destruction. Thus, the wide use of resin cements in every clinical situation should be scrutinized. A correct use with complete removal of all cement residues and a sufficient polymerization should be given the utmost attention in clinical usage.


Assuntos
Linhagem Celular/efeitos dos fármacos , Cimentos Dentários/química , Teste de Materiais , Resinas Sintéticas/química , Células A549 , Sobrevivência Celular/efeitos dos fármacos , Meios de Cultivo Condicionados , Cimentos de Ionômeros de Vidro/química , Humanos , Técnicas In Vitro , Queratinócitos/efeitos dos fármacos , L-Lactato Desidrogenase/metabolismo , Osteoblastos/metabolismo , Fosfatos/química , Polimerização , Cimentos de Resina/química , Compostos de Zinco/química , Cimento de Fosfato de Zinco/química
6.
Clin Oral Investig ; 25(8): 4895-4905, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33506428

RESUMO

OBJECTIVES: The aim of this study was, firstly, to analyse the long-time fatigue behaviour of crowns constructed from a novel polyetherketoneketone (PEKK) polymer, using artificial prepared teeth. Secondly, to determine the effect of the material's stiffness that used as an artificial prepared tooth on the fatigue life of the PEKK crowns in comparison to human prepared teeth. METHODS: Veneered crowns with a PEKK framework were constructed on three different prepared teeth: artificial polymethyl methacrylate (PMMA) teeth, artificial CoCr teeth and extracted human teeth. As far as applicable, the loading protocol was based on EN ISO 14801:2007 for fatigue testing of dental implants. After initial static fracture tests on three specimens from each group, the remaining crowns were loaded with different force levels until fracture or until 2 × 106 loading cycles were reached. The number of loading cycles until failure was recorded. Wöhler curves were created to display the fatigue limits. RESULTS: Static fracture limits as well as fatigue limits differed for all three core materials. The static fracture tests resulted in fracture limits of 1200 (± 293) N for the PMMA group, 1330 (± 219) N for the CoCr group and 899 (± 96) N for the human tooth group. Fatigue limits of 770 N, 840 N and 720 N were determined for the PMMA group, CoCr group and human tooth group, respectively. CONCLUSIONS: The determined fatigue limit of above 720 N (depending on the core material) is sufficiently high and a good performance of this crown material is expected in the clinical loading life. The results showed that using artificial teeth instead of natural teeth for fatigue testing of crowns might result in an overestimation of the fatigue limits of the crown material. CLINICAL RELEVANCE: PEKK-made crowns offer a stable and priceworthy treatment for patients, in particular those that suffer from metal allergy.


Assuntos
Coroas , Planejamento de Prótese Dentária , Benzofenonas , Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais , Polímeros
7.
J Oral Rehabil ; 48(6): 738-744, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33713361

RESUMO

BACKGROUND: Few long-term studies on treatments in the shortened dental arch (SDA) are available. OBJECTIVE: The objective of this trial was to analyse the long-term success of two different treatment concepts. METHODS: Patients over 35 years of age with missing molars in one jaw and at least the canine and one premolar present on both sides were eligible. In the partial removable dental prosthesis (PRDP) group (N = 81), molars and missing second premolars were replaced by a precision attachment retained prosthesis. In the SDA group (N = 71), the dental arch ended with the second premolar that had to be present or replaced by a cantilever fixed dental prosthesis. Follow-up examinations were carried out over 15 years. RESULTS: A comprehensive outcome variable comprised four failure categories for which Kaplan-Meier survival (success) analyses were conducted. Half of the patients exhibited a continuous preservation of the per protocol prosthetic status that remained totally unaffected by complications for more than 10 years. The event-free success rates for moderate or worse failure implied a loss of the per protocol prosthetic status. The respective survival rates fell below 50% at 14.2 years in the PRDP group and 14.3 years in the SDA group. In none of the analyses, a significant group difference was found. CONCLUSIONS: In patients with an SDA condition, changes in the prosthetic status have to be expected. The affected proportion increases almost linearly from shortly after treatment and comprises the majority after 15 years. The influence of the examined treatments on success appears to be low.


Assuntos
Prótese Parcial Removível , Arcada Parcialmente Edêntula , Perda de Dente , Dente Pré-Molar , Arco Dental , Humanos
8.
J Evid Based Dent Pract ; 21(4): 101622, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34922713

RESUMO

BACKGROUND: A shortened dental arch (SDA) is an established treatment concept for patients with missing molars. However, little is known regarding long-term course of oral health-related quality of life (OHRQoL) in patients with SDA and the benefits from replacement of missing molars. OBJECTIVE: Purpose of this multi-center randomized clinical trial was to assess OHRQoL over a period of 15 years in patients with molar replacement by a removable partial denture (RPD) compared to patients with a restored SDA without molar replacement. METHODS: Patients at least 35 years of age with all molars missing in 1 jaw and at least the canine and one premolar present on each side were included. Patients received either a precision attachment-retained, RPD for replacement of missing molars (n = 79), or the dental arch ended with the second premolar (SDA) that had to be present or replaced by a cantilever fixed dental prosthesis (n = 71). Follow-up examinations continued for 15 years. OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP). OHIP summary and dimension scores were longitudinally modeled in the statistical analyses to assess course of OHRQoL over time applying an intention-to-treat approach. In addition, scores for the OHRQoL dimensions Oral Function, Orofacial Pain, Orofacial Appearance, and Psychosocial Impact were analyzed. RESULTS: After an initial improvement in OHRQoL indicated by a mean decrease of 20.0 OHIP points with an effect size of 0.61 in the entire study population, OHRQoL stayed relatively constant over the entire follow-up period. Assuming a constant time and treatment effects over the study period, OHRQoL did not differ statistically significant between the 2 treatments (0.4 OHIP points; 95%-CI: 7.1 - 6.2). OHRQoL after treatment did not change notably over 15 years and was statistically nonsignificant as well (P = .872). Similar findings were observed in all 4 OHRQoL dimensions. CONCLUSIONS: In patients, missing all molars in one jaw OHRQoL improved providing RPD or restoring SDA to a clinically relevant degree. Treatment-related improvement remained mostly stable over a period of at least 15 years. Therefore, patients can be informed that both treatment concepts are equivalent concerning long-term OHRQoL. Accordingly, patients' preferences regarding treatment options should be granted priority in treatment decision making with the SDA treatment option being the default.


Assuntos
Prótese Parcial Removível , Qualidade de Vida , Arco Dental , Humanos , Saúde Bucal , Inquéritos e Questionários
9.
Clin Oral Investig ; 24(11): 3997-4003, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32246279

RESUMO

OBJECTIVE: This is the second part of a report on tooth loss in Germany 1997-2030. Here, we describe trends in the prevalence of edentulism in seniors 1997-2014, assess predictive factors for edentulism, and projected it into 2030. MATERIAL AND METHODS: We used data from three waves of the cross-sectional, multi-center, nationwide representative German Oral Health Studies. Overall, 3449 seniors (65-74 years) were included (1997: 1367; 2005: 1040; 2016: 1042). Age, sex, educational level, smoking status, and the cohort were entered into age-cohort binary-logistic regression models to assess the association of predictors with edentulism and to project edentulism in 2030 via Monte Carlo simulations. RESULTS: Between 1997 and 2014, the prevalence of edentulism decreased from 24.8 to 12.4%. With each year of age, the risk of being edentate increased (by 11%, p < 0.001); it was also significantly increased in female versus male (by 40%, p = 0.001), low versus medium and high educational level (up to 257%, p < 0.001), and in former and current smokers (up to 258%, p < 0.001). We predict the prevalence of edentulism to be reduced to 4.2% in 2030. The reduction will be higher in males, never and former smokers, and those with low socio-educational level. On an absolute level and despite a growing elderly population (aged 60-80 years), the number of edentate individuals will have decreased by 3.6 million in 2030 compared with 1997. CONCLUSIONS: Edentulism in seniors has declined equitably in Germany. The decline is expected to continue until 2030. Further efforts are needed to tackle the underlying risk factors. CLINICAL RELEVANCE: This study presents trends of edentulism in Germany for a period of three decades. It provides clinically relevant data for health care planning by 2030.


Assuntos
Boca Edêntula , Perda de Dente , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Boca Edêntula/epidemiologia , Prevalência , Fatores de Risco , Perda de Dente/epidemiologia
10.
Int J Comput Dent ; 23(3): 245-255, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32789312

RESUMO

AIM: The aim of the present study was to evaluate the number, strength, and position of occlusal contacts shown using an intraoral scanner (IOS) and a digital occlusal analysis system (T-Scan) compared with the current gold standard using occlusal foil (OF). MATERIALS AND METHODS: Occlusal contacts were analyzed for 70 volunteers using OF in maximum intercuspation (MI). The contact points obtained using the IOS were evaluated using a screenshot from Zirkonzahn.Modellier CAD software. Finally, the volunteers were asked to bite on the sensor sheet of the T-Scan system. For the evaluation of these data, the contact points of the OF and the IOS were graded as light, medium, and strong. Furthermore, the positions of the contact points were analyzed for the anterior region (premolars and molars). Parametric statistical tests were applied to analyze the differences among the three methods. RESULTS: The mean number of all contact points was similar: 29 ± 8 with the OF, 30 ± 12 with the IOS, and 24 ± 10 with the T-Scan. However, results were different in terms of the grading of the strength of contact points: mean number of light contacts: 8 ± 4 OF vs 17 ± 8 IOS and 17 ± 6 T-Scan; medium contacts: 12 ± 5 OF vs 8 ± 4 IOS and 5 ± 4 T-Scan; and strong contacts: 9 ± 5 OF vs 6 ± 6 IOS and 4 ± 2 T-Scan. The positions of the occlusal contact points were also different. CONCLUSION: The data sets showed that there were differences in the distribution of occlusal contact points evaluated using the OF, the IOS, and the T-Scan system. Although the number of detected occlusal contacts was similar, different occlusal contact protocols were determined by the three different methods.


Assuntos
Oclusão Dentária , Dente Molar , Dente Pré-Molar , Humanos , Software
11.
Cell Mol Life Sci ; 73(6): 1287-99, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26407611

RESUMO

In our study, ghrelin was investigated with respect to its capacity on proliferative effects and molecular correlations on oral tumor cells. The presence of all molecular components of the ghrelin system, i.e., ghrelin and its receptors, was analyzed and could be detected using real-time PCR and immunohistochemistry. To examine cellular effects caused by ghrelin and to clarify downstream-regulatory mechanisms, two different oral tumor cell lines (BHY and HN) were used in cell culture experiments. Stimulation of either cell line with ghrelin led to a significantly increased proliferation. Signal transduction occurred through phosphorylation of GSK-3ß and nuclear translocation of ß-catenin. This effect could be inhibited by blocking protein kinase A. Glucose transporter1 (GLUT1), as an important factor for delivering sufficient amounts of glucose to tumor cells having high requirements for this carbohydrate (Warburg effect) was up-regulated by exogenous and endogenous ghrelin. Silencing intracellular ghrelin concentrations using siRNA led to a significant decreased expression of GLUT1 and proliferation. In conclusion, our study describes the role for the appetite-stimulating peptide hormone ghrelin in oral cancer proliferation under the particular aspect of glucose uptake: (1) tumor cells are a source of ghrelin. (2) Ghrelin affects tumor cell proliferation through autocrine and/or paracrine activity. (3) Ghrelin modulates GLUT1 expression and thus indirectly enhances tumor cell proliferation. These findings are of major relevance, because glucose uptake is assumed to be a promising target for cancer treatment.


Assuntos
Grelina/metabolismo , Transportador de Glucose Tipo 1/metabolismo , Glucose/metabolismo , Neoplasias Bucais/metabolismo , Neoplasias Bucais/patologia , Boca/patologia , Linhagem Celular , Linhagem Celular Tumoral , Proliferação de Células , Células Cultivadas , Regulação Neoplásica da Expressão Gênica , Grelina/análise , Transportador de Glucose Tipo 1/análise , Transportador de Glucose Tipo 1/genética , Quinase 3 da Glicogênio Sintase/metabolismo , Glicogênio Sintase Quinase 3 beta , Humanos , Boca/metabolismo , Neoplasias Bucais/genética , RNA Mensageiro/genética , Transdução de Sinais , Células Tumorais Cultivadas , beta Catenina/metabolismo
12.
Clin Oral Investig ; 21(6): 1945-1951, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27785586

RESUMO

OBJECTIVES: Being a secondary outcome in a multicenter randomized controlled trial, the present analysis focused on interdental spacing in the shortened dental arch (SDA). The aim was to evaluate changes in interdental spacing in dependence of two different treatments after an observation period of up to 5 years. MATERIAL AND METHODS: Patients were either treated with a partial removable dental prosthesis (PRDP) for molar replacement (PRDP group) or according to the SDA concept aiming at a premolar occlusion (SDA group) in a randomized manner. Interdental spacing in the anterior region was measured with gauges and categorized as "0" (<0.1 mm), "1" (<0.5 mm), "2" (0.5-1 mm), and "3" (>1 mm). The statistical analysis was performed with analysis of variance models followed by linear contrast. RESULTS: Ninety-one patients (SDA n = 41, PRDP n = 50) were included. Changes of interdental spacing were detected in 70.7 % of all cases. A significant difference between the mean score changes was found in the mandible comparing the PRDP group and the SDA group. The respective mean score changes from baseline to 5 years were 0.23 (SD 0.49) for the PRDP group and 0.02 (SD 0.30) for the SDA group (p = 0.023). CONCLUSIONS: Major interdental spacing could be observed in neither of the groups. The SDA concept resulted in a slightly better outcome. CLINICAL RELEVANCE: When deciding whether to replace missing molars, the present results give further support to the SDA concept.


Assuntos
Arco Dental/patologia , Arcada Parcialmente Edêntula/reabilitação , Oclusão Dentária , Encaixe de Precisão de Dentadura , Prótese Parcial Removível , Feminino , Humanos , Masculino , Dente Molar , Odontometria , Fatores de Risco , Perda de Dente
13.
Eur J Oral Sci ; 124(3): 287-94, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27061513

RESUMO

The purpose of this study was to investigate the corrosion behavior of 10 different high noble gold-based dental alloys, used for prosthodontic retention elements, according to ISO 10271. Samples of 10 high-noble and noble gold-based dental alloys were subjected to: (i) static immersion tests with subsequent analysis of ion release for eight different elements using mass spectrometry; (ii) electrochemical tests, including open-circuit potential and potentiodynamic scans; and (iii) scanning electron microscopy, followed by energy-dispersive X-ray microscopy. The results were analyzed using one-way ANOVA and Sidak multiple-comparisons post-hoc test at a level of significance of α = 0.05. Significant differences were found among the 10 alloys studied for all ions (P < 0.001). The potentiodynamic analysis showed values from -82.5 to 102.8 mV for the open-circuit potential and from 566.7 to 1367.5 mV for the breakdown potential. Both the open-circuit and the breakdown potential varied considerably among these alloys. Scanning electron microscopy analysis confirmed the existence of typically small-diameter corrosion defects, whilst the energy-dispersive X-ray analysis found no significant alteration in the elemental composition of the alloys. The results of this study reveal the variability in the corrosive resistance among the materials used for retention elements in prosthodontics.


Assuntos
Ligas Dentárias , Prostodontia , Corrosão , Ouro , Ligas de Ouro , Teste de Materiais , Propriedades de Superfície
14.
Lasers Med Sci ; 30(2): 475-81, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23666547

RESUMO

Heat generation during the removal of dental hard tissues may lead to a temperature increase and cause painful sensations or damage dental tissues. The aim of this study was to assess heat generation in dental hard tissues following laser ablation using an ultrashort pulse laser (USPL) system. A total of 85 specimens of dental hard tissues were used, comprising 45 specimens of human dentine evaluating a thickness of 1, 2, and 3 mm (15 samples each) and 40 specimens of human enamel with a thickness of 1 and 2 mm (20 samples each). Ablation was performed with an Nd:YVO4 laser at 1,064 nm, a pulse duration of 9 ps, and a repetition rate of 500 kHz with an average output power of 6 W. Specimens were irradiated for 0.8 s. Employing a scanner system, rectangular cavities of 1-mm edge length were generated. A temperature sensor was placed at the back of the specimens, recording the temperature during the ablation process. All measurements were made employing a heat-conductive paste without any additional cooling or spray. Heat generation during laser ablation depended on the dental hard tissue (enamel or dentine) and the thickness of the respective tissue (p < 0.05). Highest temperature increase could be observed in the 1-mm thickness group for enamel. Evaluating the 1-mm group for dentine, a significantly lower temperature increase could be measured (p < 0.05) with lowest values in the 3-mm group (p < 0.05). A time delay for temperature increase during the ablation process depending on the material thickness was observed for both hard tissues (p < 0.05). Employing the USPL system to remove dental hard tissues, heat generation has to be considered. Especially during laser ablation next to pulpal tissues, painful sensations and potential thermal injury of pulp tissue might occur.


Assuntos
Esmalte Dentário , Polpa Dentária/efeitos da radiação , Dentina , Temperatura Alta , Incisivo/cirurgia , Terapia a Laser/métodos , Lasers , Dente Molar/cirurgia , Cárie Dentária/cirurgia , Dureza , Humanos
15.
Clin Oral Investig ; 18(9): 2159-69, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24452826

RESUMO

OBJECTIVES: The aim of this multi-center, randomized controlled trial was to assess the impact of missing posterior support on the risk for temporomandibular disorder (TMD) pain by comparing patients with either shortened dental arches (SDA) or molar replacement by removable dental prostheses (RDP). METHODS: A sample of 215 patients with bilateral molar loss in at least one jaw was consecutively recruited in 14 prosthodontic departments of dental schools in Germany. Of the initial sample, 152 patients (mean age: 59.7 years; 53.9 % female) received randomly allocated interventions (SDA: n = 71; RDP: n = 81). Presence of TMD pain was assessed using patients' self-reports and was verified by physical examination and by pain intensity, as the mean of current pain, worst pain, and average pain in the last 6 months, with 10-point ordinal rating scales. Assessments were performed before treatment and at follow-ups until 60 months after treatment. Impact of interventions on TMD risk and pain intensity was computed by applying logistic and linear random-intercept models. RESULTS: Tooth replacement (RDP) did not significantly change the risk for self-reported (odds ratio [OR]: 1.1; confidence interval [CI]: 0.4 to 3.4) or clinically verified (OR: 0.7; CI: 0.1 to 4.3) TMD pain compared to no tooth replacement (SDA). Mean characteristic pain intensity was virtually identical in both groups (Coeff: 0.01; CI: -0.30 to 0.32). CONCLUSION: Retaining or preservation of an SDA is not a major risk factor for TMD pain over the course of 5 years when compared to molar replacement with RPDs. CLINICAL RELEVANCE: Seemingly, missing molars do not have to be replaced in order to prevent TMD pain.


Assuntos
Arco Dental/patologia , Arcada Parcialmente Edêntula/patologia , Transtornos da Articulação Temporomandibular/etiologia , Prótese Parcial Removível , Feminino , Alemanha , Humanos , Arcada Parcialmente Edêntula/reabilitação , Masculino , Pessoa de Meia-Idade , Dente Molar , Medição da Dor , Medição de Risco , Fatores de Risco
16.
BMC Oral Health ; 14: 161, 2014 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-25547464

RESUMO

BACKGROUND: Oral diseases rank among the most prevalent non-communicable diseases in modern societies. In Germany, oral epidemiological data show that both dental caries and periodontal diseases are highly prevalent, though significant improvements in oral health has been taking in the population within the last decades, particularly in children. It is, therefore, the aim of the Fifth German Oral Health Study (DMS V) to actualize the data on current oral health status and to gather information on oral health behavior and risk factors. In addition to current oral health monitoring, the study will also permit conclusions about trends in the development of oral health in Germany between 1989 and 2014. METHODS/DESIGN: DMS V is a cross-sectional, multi-center, nationwide representative, socio-epidemiological study to investigate the oral health status und behavior of the German resident population in four age cohorts. Study participants are children (12-year-olds), adults (35- to 44-year-olds), young olds (65- to 74-year-olds), and old olds (75- to 100-year-olds) who are drawn from local residents' registration offices. Social-science investigation parameters concern subjective perceptions and attitudes regarding oral health and nutrition, sense of coherence, and socio-demographic data. Clinical oral parameters are tooth loss, caries and periodontitis, prosthodontic status, further developmental and acquired dental hard tissue and mucosal lesions. To ensure reproducibility, the dental investigators are trained and calibrated by experts and multiple reliability checks are performed throughout the field phase. Statistical analyses are calculated according to a detailed statistical analysis plan. DISCUSSION: The DMS studies first performed in 1989, 1992 and repeated in 1997 and 2005 are the only cross-sectional oral health studies conducted in Germany on a population-based national representative level. Updated prevalence and trend analyses of key oral diseases are, therefore, of major epidemiological and health services research interest. TRIAL REGISTRATION: German Health Services Research Data Bank VfD_DMSV_13_002152.


Assuntos
Saúde Bucal/estatística & dados numéricos , Doenças Periodontais/epidemiologia , Doenças Dentárias/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Atitude Frente a Saúde , Criança , Estudos de Coortes , Estudos Transversais , Cárie Dentária/epidemiologia , Inquéritos de Saúde Bucal , Prótese Dentária/estatística & dados numéricos , Estudos Epidemiológicos , Comportamento Alimentar , Alemanha/epidemiologia , Comportamentos Relacionados com a Saúde , Humanos , Doenças da Boca/epidemiologia , Periodontite/epidemiologia , Vigilância da População , Prevalência , Autoimagem , Senso de Coerência , Perda de Dente/epidemiologia
17.
J Clin Med ; 13(4)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38398475

RESUMO

Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns. Methods: Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N. Results: Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode. Conclusions: Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point.

18.
Cranio ; 31(1): 32-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23461260

RESUMO

The current study aims to analyze and quantify the effects of different registration techniques on the reproducibility of condyle position and the influence of stabilization splint therapy on the technique's reproducibility. Three-dimensional electronic-condylar-position analysis (EPA) with an ultrasound-based jaw-tracking system was recorded during intermaxillary registration of manually guided centric relation (CR), maximal intercuspation (MI), and clenching-force-dependent Gothic arch tracing guided centric relation (DIR method) before (T0) and after (T1) splint therapy. Patients were supplied with a stabilization splint for three months on the basis of the DIR registration. Participants were 26 asymptomatic volunteers with a mean age of 30.6 +/- 9.5 years. The registration technique was found to have a significant (p = 0.001) effect on condylar displacement in all axes before, and in X- and Y-axes after splint therapy. Condyles during DIR were found to be in a more anterior-inferior position compared with CR and MI, with the condyles in the latter position being likewise more anterior than in CR. There were significant (p < 0.03) differences in reproducibility of the condyle position dependent on the technique, both at T0 and T1. The DIR method showed the highest reproducibility, followed by MI and CR. There was no significant effect of time of investigation on the technique's reproducibility.


Assuntos
Relação Central , Registro da Relação Maxilomandibular/métodos , Côndilo Mandibular/fisiologia , Placas Oclusais , Adulto , Análise de Variância , Força de Mordida , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
19.
Biomed Tech (Berl) ; 68(3): 241-250, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-36795430

RESUMO

OBJECTIVES: Although the use of short implants is becoming more common for patients with atrophic alveolar ridges, their use is still quite limited. This is due to the lack of data of long-term survival compared to standard-length implants. The aim of this study was to determine the load in the bone and implant system with different superstructures. METHODS: Three kinds of prosthetic restorations were created on short implants based on CT-Data. Two short implants with different macro-geometries were used. The implants were inserted in idealised posterior lower mandibular segments and afterwards restored with a crown, a double splinted crown, and a bridge. RESULTS: The analysis was performed under load of 300 N either divided between a mesial and distal point or as a point load on the pontic/mesial crown. The different design of the implant systems had a noticeable influence on the stress in the cortical bone, in the implant system, and the displacement of the superstructure as well. CONCLUSIONS: Compared with implants of standard length, higher stresses were observed, which can lead early failure of the implant during the healing period or a late cervical bone resorption. Precise indications are essential for short implants to avoid the failure of short implants.


Assuntos
Processo Alveolar , Implantes Dentários , Humanos , Análise de Elementos Finitos , Coroas , Mandíbula/cirurgia , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Planejamento de Prótese Dentária , Estresse Mecânico , Fenômenos Biomecânicos
20.
J Funct Biomater ; 14(9)2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37754883

RESUMO

(1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25-50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant's superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA