Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 25(1): 48, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37574552

RESUMO

Transcatheter cardiovascular interventions increasingly rely on advanced imaging. X-ray fluoroscopy provides excellent visualization of catheters and devices, but poor visualization of anatomy. In contrast, magnetic resonance imaging (MRI) provides excellent visualization of anatomy and can generate real-time imaging with frame rates similar to X-ray fluoroscopy. Realization of MRI as a primary imaging modality for cardiovascular interventions has been slow, largely because existing guidewires, catheters and other devices create imaging artifacts and can heat dangerously. Nonetheless, numerous clinical centers have started interventional cardiovascular magnetic resonance (iCMR) programs for invasive hemodynamic studies or electrophysiology procedures to leverage the clear advantages of MRI tissue characterization, to quantify cardiac chamber function and flow, and to avoid ionizing radiation exposure. Clinical implementation of more complex cardiovascular interventions has been challenging because catheters and other tools require re-engineering for safety and conspicuity in the iCMR environment. However, recent innovations in scanner and interventional device technology, in particular availability of high performance low-field MRI scanners could be the inflection point, enabling a new generation of iCMR procedures. In this review we review these technical considerations, summarize contemporary clinical iCMR experience, and consider potential future applications.


Assuntos
Cateterismo Cardíaco , Imagem por Ressonância Magnética Intervencionista , Humanos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
2.
J Cardiovasc Magn Reson ; 20(1): 41, 2018 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-29925397

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) fluoroscopy allows for simultaneous measurement of cardiac function, flow and chamber pressure during diagnostic heart catheterization. To date, commercial metallic guidewires were considered contraindicated during CMR fluoroscopy due to concerns over radiofrequency (RF)-induced heating. The inability to use metallic guidewires hampers catheter navigation in patients with challenging anatomy. Here we use low specific absorption rate (SAR) imaging from gradient echo spiral acquisitions and a commercial nitinol guidewire for CMR fluoroscopy right heart catheterization in patients. METHODS: The low-SAR imaging protocol used a reduced flip angle gradient echo acquisition (10° vs 45°) and a longer repetition time (TR) spiral readout (10 ms vs 2.98 ms). Temperature was measured in vitro in the ASTM 2182 gel phantom and post-mortem animal experiments to ensure freedom from heating with the selected guidewire (150 cm × 0.035″ angled-tip nitinol Terumo Glidewire). Seven patients underwent CMR fluoroscopy catheterization. Time to enter each chamber (superior vena cava, main pulmonary artery, and each branch pulmonary artery) was recorded and device visibility and confidence in catheter and guidewire position were scored on a Likert-type scale. RESULTS: Negligible heating (< 0.07°C) was observed under all in vitro conditions using this guidewire and imaging approach. In patients, chamber entry was successful in 100% of attempts with a guidewire compared to 94% without a guidewire, with failures to reach the branch pulmonary arteries. Time-to-enter each chamber was similar (p=NS) for  the two approaches. The guidewire imparted useful catheter shaft conspicuity and enabled interactive modification of catheter shaft stiffness, however, the guidewire tip visibility was poor. CONCLUSIONS: Under specific conditions, trained operators can apply low-SAR imaging and using a specific fully-insulated metallic nitinol guidewire (150 cm × 0.035" Terumo Glidewire) to augment clinical CMR fluoroscopy right heart catheterization. TRIAL REGISTRATION: Clinicaltrials.gov NCT03152773 , registered May 15, 2017.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Ligas , Animais , Cateterismo Cardíaco/efeitos adversos , Desenho de Equipamento , Temperatura Alta , Humanos , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Teste de Materiais , Modelos Animais , Imagens de Fantasmas , Valor Preditivo dos Testes , Sus scrofa , Fatores de Tempo , Fluxo de Trabalho
3.
Eur Heart J ; 34(5): 380-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22855740

RESUMO

AIMS: Real-time MRI creates images with superb tissue contrast that may enable radiation-free catheterization. Simple procedures are the first step towards novel interventional procedures. We aim to perform comprehensive transfemoral diagnostic right heart catheterization in an unselected cohort of patients entirely using MRI guidance. METHODS AND RESULTS: We performed X-ray and MRI-guided transfemoral right heart catheterization in consecutive patients undergoing clinical cardiac catheterization. We sampled both cavae and both pulmonary arteries. We compared success rate, time to perform key steps, and catheter visibility among X-ray and MRI procedures using air-filled or gadolinium-filled balloon-tipped catheters. Sixteen subjects (four with shunt, nine with coronary artery disease, three with other) underwent paired X-ray and MRI catheterization. Complete guidewire-free catheterization was possible in 15 of 16 under both. MRI using gadolinium-filled balloons was at least as successful as X-ray in all procedure steps, more successful than MRI using air-filled balloons, and better than both in entering the left pulmonary artery. Total catheterization time and individual procedure steps required approximately the same amount of time irrespective of image guidance modality. Catheter conspicuity was best under X-ray and next-best using gadolinium-filled MRI balloons. CONCLUSION: In this early experience, comprehensive transfemoral right heart catheterization appears feasible using only MRI for imaging guidance. Gadolinium-filled balloon catheters were more conspicuous than air-filled ones. Further workflow and device enhancement are necessary for clinical adoption.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias/diagnóstico , Meios de Contraste , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Angiografia por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Radiografia Intervencionista/métodos
4.
JACC Cardiovasc Interv ; 15(12): 1249-1263, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35738745

RESUMO

BACKGROUND: Transcatheter mitral valve repair is beneficial in patients with mitral regurgitation (MR), left ventricular dysfunction, and persistent symptoms despite maximally tolerated medical therapy. OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of transcatheter mitral cerclage ventriculoplasty in patients with MR and either heart failure with reduced ejection fraction or preserved ejection fraction and in subjects with prior edge-to-edge repair but persistent or recurrent symptomatic MR. METHODS: The National Heart, Lung, and Blood Institute Division of Intramural Research Transcatheter Mitral Cerclage Ventriculoplasty Early Feasibility Study (NCT03929913) was an investigator-initiated prospective multicenter study. The primary endpoint was technical success measured at exit from the catheterization laboratory. Follow-up included heart failure quality-of-life assessments and serial imaging with echocardiography and cardiac computed tomography. RESULTS: Nineteen subjects consented and underwent cerclage, 63% with heart failure with reduced ejection fraction and 37% with heart failure with preserved ejection fraction, with ischemic cardiomyopathy in 26% and nonischemic cardiomyopathy in 74%. There were no procedural deaths, strokes, or transient ischemic attacks or other major cardiovascular adverse events. The primary endpoint was met in 17 subjects. Cerclage induced sustained reductions in mitral regurgitant volume (-41%) and effective orifice area (-33%) after a median of 337 days. Cerclage resulted in improvements in 6-minute walking distance (+78 m) and Kansas City Cardiomyopathy Questionnaire Overall Summary Score (+22 points) at 30 days that were maintained after a median of 265 days. New complete heart block developed in 6 of 17 subjects. Three deaths occurred on postprocedural days 79, 159, and 756, unrelated to cerclage. CONCLUSIONS: Transcatheter mitral cerclage ventriculoplasty resulted in significant and sustained improvements in mitral regurgitation and in heart failure quality-of-life assessments.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
5.
Circ Cardiovasc Interv ; 14(5): e010238, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-34003670

RESUMO

BACKGROUND: Coronary artery obstruction is a rare, devastating complication of transcatheter aortic valve replacement. Transcatheter electrosurgical aortic leaflet laceration (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) is a novel technique to prevent coronary artery obstruction. We report the 1-year outcomes of the BASILICA trial. Primary end points of 30-day success and safety have been reported previously. METHODS: The BASILICA trial was a prospective, multicenter, single-arm safety and feasibility study. Subjects with severe native or bioprosthetic aortic valve disease at high or extreme risk for surgery, and high risk of coronary artery obstruction, were included. End points at 1 year included death, stroke, and myocardial infarction. Source data was independently verified and end points independently adjudicated. RESULTS: Thirty subjects were enrolled between February 2018 and July 2018. At 30 days, BASILICA was successful in 28 subjects (93.3%), there were 3 strokes (10%), including 1 disabling stroke (3.3%), 1 death (3.3%), and 1 periprocedural myocardial infarction (3.3%). Between 30 days and 1 year, there were no additional strokes, no myocardial infarction, and 2 deaths (10% 1-year mortality). No subject needed repeat intervention for aortic valve or coronary disease. Two subjects had infective endocarditis (6.7%), but neither was isolated to the aortic valve. There were no hospital admissions for heart failure. Fourteen (46.7%) subjects required repeat hospital admission for other causes. Aortic valve gradients on echocardiography, New York Heart Association functional class, and Kansas City Cardiomyopathy Questionnaire scores improved from baseline to 30 days and were maintained at 1 year. CONCLUSIONS: In these subjects with multiple comorbidities and restrictive anatomy that underwent transcatheter aortic valve replacement, there was no late stroke, myocardial infarction, or death related to BASILICA. Mitigation of coronary obstruction remained intact at 1 year and was not related to recurrent readmission. These results are reassuring for patients and physicians who wish to avoid the long-term complications related to snorkel stenting. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03381989.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Eletrocirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
JACC Cardiovasc Interv ; 12(21): 2198-2206, 2019 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-31629746

RESUMO

OBJECTIVES: This study sought to test safety and exploratory effectiveness of a dedicated transcaval closure device (TCD). BACKGROUND: Transcaval access enables delivery of large-caliber devices to the aorta in patients ineligible for transfemoral arterial access. Closure of aortocaval fistulae using off-label nitinol cardiac occluders has been shown to be safe, but persistent aortocaval fistulae at exit from the catheterization lab and bleeding complications were common in a prospective study. METHODS: Preclinical testing of the TCD was performed in 24 Yorkshire swine, including 10 under good laboratory practice conditions. Subsequently, subjects undergoing transcatheter aortic valve replacement for symptomatic severe aortic stenosis, ineligible for transfemoral arterial access, were enrolled in a U.S. Food and Drug Administration-approved early feasibility study of the TCD (Transmural Systems, Andover, Massachusetts). Independently adjudicated endpoints included technical, device, and procedural success, incorporating in-hospital and 30-day clinical and imaging follow-up. RESULTS: Transcaval access and closure in swine confirmed that at 30 days, TCDs were almost entirely endothelialized. Subsequently, 12 subjects were enrolled in the early feasibility study. Transcaval access, transcatheter aortic valve replacement, and aortocaval fistula closure was successful in all 12 subjects. The primary endpoint of technical success was met in 100% of subjects. Complete closure of the transcaval access tract was achieved in 75% of subjects at exit from the catheterization lab and in 100% of subjects at 30 days. There were zero modified Valve Academic Research Consortium-2 major vascular complications and zero Valve Academic Research Consortium-2 life-threatening or major bleeding complications related to transcaval access or the TCD. CONCLUSIONS: The TCD achieved complete closure of the transcaval access tract in most subjects at exit from the catheterization lab and essentially eliminated transcaval-related bleeding. Dedicated devices for transcaval access and closure could enable more widespread adoption of transcaval techniques without fear of bleeding complications. (Transmural Systems Transcaval Closure Device for Transcaval Access Ports During Transcatheter Aortic Valve Replacement; NCT03432494).


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Veias Cavas , Idoso , Idoso de 80 Anos ou mais , Animais , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Modelos Animais , Estudos Prospectivos , Punções , Fatores de Risco , Sus scrofa , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Estados Unidos , Veias Cavas/diagnóstico por imagem
7.
JACC Cardiovasc Interv ; 12(5): 448-456, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30846083

RESUMO

OBJECTIVES: The authors investigated 1-year outcomes after transcaval access and closure for transcatheter aortic valve replacement (TAVR), using commercially available nitinol cardiac occluders off-label. BACKGROUND: Transcaval access is a fully percutaneous nonfemoral artery route for TAVR. The intermediate-term fate of transcaval access tracts is not known. METHODS: The authors performed a prospective, multicenter, independently adjudicated trial of transcaval access, using Amplatzer nitinol cardiac occluders (Abbott Vascular, Minneapolis, Minnesota), among subjects without traditional transthoracic (transapical or transaortic) access options. One-year clinical follow-up included core laboratory analysis of serial abdominal computed tomography (CT). RESULTS: 100 subjects were enrolled. Twelve-month mortality was 29%. After discharge, there were no vascular complications of transcaval access. Among 83 evaluable CT scans after 12 months, 77 of fistulas (93%) were proven occluded, and only 1 was proven patent. Fistula patency was not associated with overall survival (p = 0.37), nor with heart failure admissions (15% if patent vs. 23% if occluded; p = 0.30). There were no cases of occluder fracture or migration or visceral injury. CONCLUSIONS: Results are reassuring 1 year after transcaval TAVR and closure using permeable nitinol occluders off-label. There were no late major vascular complications. CT demonstrated spontaneous closure of almost all fistulas. Results may be different in a lower-risk cohort, with increased operator experience, and using a dedicated transcaval closure device. (Transcaval Access for Transcatheter Aortic Valve Replacement in People With No Good Options for Aortic Access; NCT02280824).


Assuntos
Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Substituição da Valva Aórtica Transcateter , Veia Cava Inferior , Idoso , Idoso de 80 Anos ou mais , Ligas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Punções , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Dispositivos de Oclusão Vascular , Lesões do Sistema Vascular/etiologia , Veia Cava Inferior/diagnóstico por imagem
8.
JACC Cardiovasc Interv ; 12(13): 1240-1252, 2019 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-31202947

RESUMO

OBJECTIVES: The BASILICA (Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction during TAVR) investigational device exemption trial was a prospective, multicenter, single-arm safety and feasibility study. BACKGROUND: Coronary artery obstruction is a rare but devastating complication of transcatheter aortic valve replacement (TAVR). Current stent-based preventative strategies are suboptimal. Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction during TAVR (BASILICA) is a novel transcatheter technique performed immediately before TAVR to prevent coronary artery obstruction. METHODS: Subjects with severe native or bioprosthetic aortic valve disease at high or extreme risk for surgery, and at high risk of coronary artery obstruction, were included. The primary success endpoint was successful BASILICA and TAVR without coronary obstruction or reintervention. The primary safety endpoint was freedom from major adverse cardiovascular events. Data were independently monitored. Endpoints were independently adjudicated. A core laboratory analyzed computed tomography images. RESULTS: Between February 2018 and July 2018, 30 subjects were enrolled. Primary success was met in 28 (93%) subjects. BASILICA traversal and laceration was successful in 35 of 37 (95%) attempted leaflets. There was 100% freedom from coronary obstruction and reintervention. Primary safety was met in 21 (70%), driven by 6 (20%) major vascular complications related to TAVR but not BASILICA. There was 1 death at 30 days. There was 1 (3%) disabling stroke and 2 (7%) nondisabling strokes. Transient hemodynamic compromise was rare (7%) and resolved promptly with TAVR. CONCLUSIONS: BASILICA was feasible in both native and bioprosthetic valves. Hemodynamic compromise was uncommon. Safety was acceptable and needs confirmation in larger studies. BASILICA appears effective in preventing coronary artery obstruction from TAVR in subjects at high risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Estenose Coronária/prevenção & controle , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Doença Iatrogênica/prevenção & controle , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/etiologia , Estenose Coronária/fisiopatologia , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos
9.
J Am Coll Cardiol ; 73(20): 2521-2534, 2019 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-31118146

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a leading cause of mortality and exclusion from transcatheter mitral valve replacement (TMVR). Intentional laceration of the anterior mitral valve leaflet to prevent LVOT obstruction (LAMPOON) is a transcatheter mimic of surgical chord-sparing leaflet resection. OBJECTIVES: The purpose of this prospective multicenter trial was to study LAMPOON with transseptal (Edwards Lifesciences, Irvine, California) TMVR in annuloplasty rings or native mitral annular calcification (MAC). METHODS: Subjects at high or extreme surgical risk and prohibitive risk of LVOT obstruction from TMVR were included. Eligibility was modified midtrial to exclude subjects with threatened LVOT obstruction from a Sapien 3 valve fabric skirt. The primary endpoint was procedure survival with successful LAMPOON, with successful TMVR, without reintervention, and with LVOT gradient <30 mm Hg ("optimal") or <50 mm Hg ("acceptable"). Secondary endpoints included 30-day mortality and major adverse cardiovascular events. There was universal source-data verification and independent monitoring. All endpoints were independently adjudicated. Central laboratories analyzed echocardiogram and CT images. RESULTS: Between June 2017 and June 2018, 30 subjects were enrolled equally between the MAC and ring arms. LAMPOON traversal and midline laceration was successful in 100%. Procedure survival was 100%, and 30-day survival was 93%. Primary success was achieved in 73%, driven by additional procedures for paravalvular leak (10%) and high-skirt neo-LVOT gradients observed before a protocol amendment. There were no strokes. CONCLUSIONS: LAMPOON was feasible in native and annuloplasty ring anatomies in patients who were otherwise ineligible for treatment, with acceptable safety. LAMPOON was effective in preventing LVOT obstruction from TMVR. Despite LAMPOON, TMVR using Sapien 3 in annuloplasty rings and MAC still exhibits important limitations. (NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation; NCT03015194).


Assuntos
Cateterismo Cardíaco/métodos , Eletrocirurgia/métodos , Septos Cardíacos/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Septos Cardíacos/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/etiologia
10.
J Am Coll Cardiol ; 69(5): 511-521, 2017 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-27989885

RESUMO

BACKGROUND: Transcaval access may enable fully percutaneous transcatheter aortic valve replacement (TAVR) without the hazards and discomfort of transthoracic (transapical or transaortic) access. OBJECTIVES: The authors performed a prospective, independently adjudicated, multicenter, single-arm trial of transcaval access for TAVR in patients who were ineligible for femoral artery access and had high or prohibitive risk of complications from transthoracic access. METHODS: A total of 100 patients underwent attempted percutaneous transcaval access to the abdominal aorta by electrifying a caval guidewire and advancing it into a pre-positioned aortic snare. After exchanging for a rigid guidewire, conventional TAVR was performed through transcaval introducer sheaths. Transcaval access ports were closed with nitinol cardiac occluders. A core laboratory analyzed pre-discharge and 30-day abdominal computed tomograms. The Society of Thoracic Surgeons predicted risk of mortality was 9.6 ± 6.3%. RESULTS: Transcaval access was successful in 99 of 100 patients. Device success (access and closure with a nitinol cardiac occluder without death or emergency surgical rescue) occurred 98 of 99 patients; 1 subject had closure with a covered stent. Inpatient survival was 96%, and 30-day survival was 92%. Second Valve Academic Research Consortium (VARC-2) life-threatening bleeding and modified VARC-2 major vascular complications possibly related to transcaval access were 7% and 13%, respectively. Median length of stay was 4 days (range 2 to 6 days). There were no vascular complications after discharge. CONCLUSIONS: Transcaval access enabled TAVR in patients who were not good candidates for transthoracic access. Bleeding and vascular complications, using permeable nitinol cardiac occluders to close the access ports, were common but acceptable in this high-risk cohort. Transcaval access should be investigated in patients who are eligible for transthoracic access. Purpose-built closure devices are in development that may simplify the procedure and reduce bleeding. (Transcaval Access for Transcatheter Aortic Valve Replacement in People With No Good Options for Aortic Access; NCT02280824).


Assuntos
Valva Aórtica/cirurgia , Idoso , Cateterismo/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Veias Cavas
11.
Catheter Cardiovasc Interv ; 70(6): 773-82, 2007 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-18022851

RESUMO

BACKGROUND: We have developed and validated a system for real-time X-ray fused with magnetic resonance imaging, MRI (XFM), to guide catheter procedures with high spatial precision. Our implementation overlays roadmaps-MRI-derived soft-tissue features of interest-onto conventional X-ray fluoroscopy. We report our initial clinical experience applying XFM, using external fiducial markers, electrocardiogram (ECG)- gating, and automated real-time correction for gantry and table movement. METHODS: This prospective case series for technical development was approved by the NHLBI Institutional Review Board and included 19 subjects. Multimodality external fiducial markers were affixed to patients' skin before MRI, which included contrast-enhanced, 3D T1-weighted, or breath-held and ECG-gated 2D steady state free precession imaging at 1.5T. MRI-derived roadmaps were manually segmented while patients were transferred to a calibrated X-ray fluoroscopy system. Image spaces were registered using the fiducial markers and thereafter permitted unrestricted gantry rotation, table panning, and magnification changes. Static and ECG-gated MRI data were transformed from 3D to 2D to correspond with gantry and table position and combined with live X-ray images. RESULTS: Clinical procedures included graft coronary arteriography, right ventricular free-wall biopsy, and iliac and femoral artery recanalization and stenting. MRI roadmaps improved operator confidence, and in the biopsy cases, outperformed the best available alternative imaging modality. Registration errors were increased when external fiducial markers were affixed to more mobile skin positions, such as over the abdomen. CONCLUSION: XFM using external fiducial markers is feasible during X-ray guided catheter treatments. Multimodality image fusion may prove a useful adjunct to invasive cardiovascular procedures.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Fluoroscopia/métodos , Cardiopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Monitorização Intraoperatória/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Diagnóstico Diferencial , Cardiopatias/cirurgia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Catheter Cardiovasc Interv ; 64(3): 265-74, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15736247

RESUMO

We tested the feasibility and safety of invasive magnetic resonance imaging (MRI) during peripheral angioplasty. Real-time MRI can image soft tissue and may potentially guide therapeutic procedures without ionizing radiation or nephrotoxic contrast. MRI-guided diagnostic catheterization has been described recently, but safe and conspicuous catheter devices are not widely available. An active guidewire, which serves as an MRI receiver antenna, might be useful to guide catheterization or even to image atheroma. We describe a combined interventional suite offering both X-ray fluoroscopy and real-time MRI. We used a 0.030'' active guidewire receiver coil for invasive MRI after X-ray lesion traversal in patients undergoing percutaneous iliofemoral artery revascularization. Intravascular MRI was compared with noninvasive MRI, X-ray angiography, and intravascular ultrasound (IVUS). Seven eligible patients consented to participate, but three were excluded because of lengthy revascularization procedures. Four remaining patients safely underwent combined X-ray fluoroscopy and real-time magnetic resonance imaging (XMR) transport, continuous monitoring, and all imaging modalities. There was no device dislodgment, contamination or evidence of heating. The intravascular MRI coil was well visualized except at the tip, but did not provide superior mural imaging compared with IVUS. Therefore, because an adequate safety and workflow experience was obtained, enrollment was terminated after only four subjects. Invasive MRI is feasible and apparently safe during peripheral angioplasty. Patients can safely be transported and monitored in an XMR interventional suite. An active quarter-wavelength guidewire coil does not provide superior imaging compared with IVUS, but provides satisfactory guidewire visualization. These tools may prove useful for advanced therapeutic procedures in the future.


Assuntos
Angioplastia com Balão , Claudicação Intermitente/diagnóstico , Angiografia por Ressonância Magnética , Salas Cirúrgicas , Serviço Hospitalar de Radiologia , Idoso , Angiografia , Segurança de Equipamentos , Estudos de Viabilidade , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Claudicação Intermitente/terapia , Período Intraoperatório , Angiografia por Ressonância Magnética/instrumentação , Angiografia por Ressonância Magnética/normas , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA