Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 384(11): 1015-1027, 2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33523609

RESUMO

BACKGROUND: Convalescent plasma has been widely used to treat coronavirus disease 2019 (Covid-19) under the presumption that such plasma contains potentially therapeutic antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that can be passively transferred to the plasma recipient. Whether convalescent plasma with high antibody levels rather than low antibody levels is associated with a lower risk of death is unknown. METHODS: In a retrospective study based on a U.S. national registry, we determined the anti-SARS-CoV-2 IgG antibody levels in convalescent plasma used to treat hospitalized adults with Covid-19. The primary outcome was death within 30 days after plasma transfusion. Patients who were enrolled through July 4, 2020, and for whom data on anti-SARS-CoV-2 antibody levels in plasma transfusions and on 30-day mortality were available were included in the analysis. RESULTS: Of the 3082 patients included in this analysis, death within 30 days after plasma transfusion occurred in 115 of 515 patients (22.3%) in the high-titer group, 549 of 2006 patients (27.4%) in the medium-titer group, and 166 of 561 patients (29.6%) in the low-titer group. The association of anti-SARS-CoV-2 antibody levels with the risk of death from Covid-19 was moderated by mechanical ventilation status. A lower risk of death within 30 days in the high-titer group than in the low-titer group was observed among patients who had not received mechanical ventilation before transfusion (relative risk, 0.66; 95% confidence interval [CI], 0.48 to 0.91), and no effect on the risk of death was observed among patients who had received mechanical ventilation (relative risk, 1.02; 95% CI, 0.78 to 1.32). CONCLUSIONS: Among patients hospitalized with Covid-19 who were not receiving mechanical ventilation, transfusion of plasma with higher anti-SARS-CoV-2 IgG antibody levels was associated with a lower risk of death than transfusion of plasma with lower antibody levels. (Funded by the Department of Health and Human Services and others; ClinicalTrials.gov number, NCT04338360.).


Assuntos
Anticorpos Antivirais/sangue , COVID-19/terapia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/imunologia , COVID-19/mortalidade , Feminino , Hospitalização , Humanos , Imunização Passiva , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Respiração Artificial , Estudos Retrospectivos , Fatores de Risco , Tempo para o Tratamento , Estados Unidos/epidemiologia , Adulto Jovem , Soroterapia para COVID-19
2.
Transfusion ; 64(1): 47-52, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38115202

RESUMO

BACKGROUND: Recently the US Food and Drug Administration has granted variances to select blood centers to supply cold-stored platelet components (CSP). In hemorrhage resuscitation warming of blood components with approved fluid warming devices is common. STUDY DESIGN AND METHODS: Pathogen-reduced apheresis platelet units were collected and stored in one of two ways: (1) CSP-I, (2) CSP-D. CSP-I were collected and immediately stored at 1-6°C until used. CSP-D were collected and stored at 20-24°C for 5 days and transferred to storage at 1-6°C until use. Aggregometry using arachidonic acid (AA), adenosine diphosphate (ADP) and collagen as agonists was performed on the unit samples before and after the units were infused through a Ranger blood-warming device. RESULTS: CSP-I, 23 units, had very high aggregation responses to all agonists (all ≥47.6 ± 20.7). There was a statistically significant reduction in ADP-induced aggregometry results from 55.1 ± 23.2 before compared to 33.5 ± 14.6 following infusion of the PLT through the blood warmer (p < .001). There were no differences in AA and collagen aggregometry results before and after the infusion of the platelets through the blood warmer. CSP-D had 5 of the 15 units with visible clotting in the bag. The 10 CSP-Ds studied had lower aggregation than all agonists before and after infusion through the blood-warming device (all ≤49.9 ± 35.9). CONCLUSION: We detected a statistically significant reduction in ADP-induced aggregometry in CSP-I run through a Ranger blood-warming device with no change with AA or collagen agonist aggregometry.


Assuntos
Agregação Plaquetária , Transfusão de Plaquetas , Humanos , Transfusão de Plaquetas/métodos , Plaquetas , Colágeno/farmacologia , Difosfato de Adenosina/farmacologia , Preservação de Sangue/métodos , Temperatura Baixa
3.
Transfusion ; 63(3): 552-563, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36550639

RESUMO

BACKGROUND: Previous studies have demonstrated low first-time donor return rates (DRR) following catastrophic events. Little is known, however, about the influence of demographic factors on the DRR of first-time donors during the COVID-19 pandemic, including the unique motivation of COVID-19 convalescent plasma (CCP) donors as compared to non-CCP donors. STUDY DESIGN AND METHODS: Thirteen blood collection organizations submitted deidentified data from first-time CCP and non-CCP donors returning for regular (non-CCP) donations during the pandemic. DRR was calculated as frequencies. Demographic factors associated with returning donors: race/ethnicity, gender, and generation (Gen Z: 19-24, Millennial: 25-40, Gen X: 41-56, and Boomer: ≥57 years old), within the CCP and non-CCP first-time cohorts were compared using chi-square test at p < .05 statistical significance. RESULTS: From March 2020 through December 2021, there were a total of 44,274 first-time CCP and 980,201 first-time non-CCP donors. DRR were 14.6% (range 11.9%-43.3%) and 46.6% (range 10.0%-76.9%) for CCP and non-CCP cohorts, respectively. Age over 40 years (Gen X and Boomers), female gender, and White race were each associated with higher return in both donor cohorts (p < .001). For the non-CCP return donor cohort, the Millennial and Boomers were comparable. CONCLUSION: The findings demonstrate differences in returning donor trends between the two donor cohorts. The motivation of a first-time CCP donor may be different than that of a non-CCP donor. Further study to improve first-time donor engagement would be worthwhile to expand the donor base with a focus on blood donor diversity emphasizing engagement of underrepresented minorities and younger donors.


Assuntos
Doadores de Sangue , COVID-19 , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Pandemias , COVID-19/epidemiologia , COVID-19/terapia , Soroterapia para COVID-19 , Etnicidade
4.
Anesthesiology ; 139(2): 153-163, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37155364

RESUMO

BACKGROUND: Delayed cold storage of room temperature platelets may extend shelf life from 5 to 14 days. The study hypothesized that the use of delayed cold-stored platelets in cardiac surgery would be associated with decreased postoperative platelet count increments but similar transfusion and clinical outcomes compared to room temperature-stored platelets. METHODS: This is an observational cohort study of adults transfused with platelets intraoperatively during elective cardiac surgery between April 2020 and May 2021. Intraoperative platelets were either room temperature-stored or delayed cold-stored based on blood bank availability rather than clinical features or provider preference. Differences in transfusion and clinical outcomes, including a primary outcome of allogenic transfusion exposure in the first 24 h postoperatively, were compared between groups. RESULTS: A total of 713 patient encounters were included: 529 (74%) room temperature-stored platelets and 184 (26%) delayed cold-stored platelets. Median (interquartile range) intraoperative platelet volumes were 1 (1 to 2) units in both groups. Patients receiving delayed cold-stored platelets had higher odds of allogeneic transfusion in the first 24 h postoperatively (81 of 184 [44%] vs. 169 of 529 [32%]; adjusted odds ratio, 1.65; 95% CI, 1.13 to 2.39; P = 0.009), including both erythrocytes (65 of 184 [35%] vs. 135 of 529 [26%]; adjusted odds ratio, 1.54; 95% CI, 1.03 to 2.29; P = 0.035) and platelets (48 of 184 [26%] vs. 79 of 529 [15%]; adjusted odds ratio, 1.91; 95% CI, 1.22 to 2.99; P = 0.005). There was no difference in the number of units administered postoperatively among those transfused. Platelet counts were modestly lower in the delayed cold-stored platelet group (-9 × 109/l; 95% CI, -16 to -3]) through the first 3 days postoperatively. There were no significant differences in reoperation for bleeding, postoperative chest tube output, or clinical outcomes. CONCLUSIONS: In adults undergoing cardiac surgery, delayed cold-stored platelets were associated with higher postoperative transfusion utilization and lower platelet counts compared to room temperature-stored platelets without differences in clinical outcomes. The use of delayed cold-stored platelets in this setting may offer a viable alternative when facing critical platelet inventories but is not recommended as a primary transfusion approach.


Assuntos
Plaquetas , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Transfusão de Plaquetas , Temperatura , Estudos Retrospectivos , Preservação de Sangue
5.
Transfus Apher Sci ; 62(3): 103639, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36631316

RESUMO

Platelet transfusions decreased the risk of morbidity and mortality secondary to thrombocytopenia. This therapy not only ameliorates platelet loss in bleeding patients,but also those with acquired dysfunction of platelets. The current standard of practice worldwide is to provide room temperature platelets (RTPs); however, there are many disadvantages to the use of RTPs such that alternative approaches have been explored. One potential approach is the integration and use of cold stored platelets (CSP), which are platelets stored at 1-6 °C, in clinical settings. CSP research studies show equivalent hemostasis and platelet dysfunction restoration compared to RTPs. In addition, publications have demonstrated advantages of CSP such as reduced bacterial contamination and wastage. Despite its benefits, the production of CSP by blood centers (BCs) and uptake and use of CSP by hospitals has remained relatively low. This review highlights the rationale for CSP production and strategies for overcoming the implementation challenges faced by BCs based on a literature review.Experiences of Consortium for Blood Availability members to integrate CSP in their BCs and clinical practices by providing variance applications are reviewed in this paper. Also, demonstrated in this manuscript are the current indications and opportunities for CSP utilization by healthcare providers.


Assuntos
Plaquetas , Trombocitopenia , Humanos , Transfusão de Plaquetas , Temperatura Baixa , Trombocitopenia/terapia , Hemorragia/terapia , Preservação de Sangue
6.
Cytotherapy ; 24(1): 19-26, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34980364

RESUMO

BACKGROUND: The rise of investigative and commercially available cell therapy products adds a new dynamic to academic medical centers; that is, the management of patient-specific cell products. The scope of cell therapy has rapidly expanded beyond in-house collection and infusion of cell products such as bone marrow and peripheral blood transplant. The complexities and volumes of cell therapies are likely to continue to become more demanding. As patient-specific "living drugs," cell therapy products typically require material collection, product provenance, transportation and maintenance of critical quality attributes, including temperature and expiration dates. These requirements are complicated by variations in product-specific attributes, reporting requirements and interactions with industry not required of typical pharmaceuticals. METHODS: To manage these requirements, the authors set out to establish a framework within the Immune, Progenitor and Cell Therapeutics Lab, the Current Good Manufacturing Practice facility responsible for cell manufacturing at Mayo Clinic Rochester housed within the Division of Transfusion Medicine. The authors created a work unit (biopharmaceutical unit) dedicated to addressing the specialized procedures required to properly handle these living drugs from collection to delivery and housing the necessary processes to more easily integrate externally manufactured cell therapies into clinical practice. RESULTS: The result is a clear set of expectations defined for each step of the process, with logical documentation of critical steps that are concise and easy to follow. CONCLUSIONS: The authors believe this system is scalable for addressing the promised growth of cell therapy products well into the future. Here the authors describe this system and provide a framework that could be used by other centers to manage these important new therapies.


Assuntos
Produtos Biológicos , Preparações Farmacêuticas , Terapia Baseada em Transplante de Células e Tecidos , Comércio , Humanos
7.
Transfusion ; 62 Suppl 1: S1-S11, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35765971

RESUMO

BACKGROUND: A specialized international multidisciplinary group of investigators wanted to determine the performance and impact of publications presented at an annual conference over a 6 year period. Specifically, the group wanted to know if the influence of the conference publications extended beyond conference publication authors and attendees. Bibliometric methods and network analyses were used to evaluate the performance and impact of 100 peer-reviewed publications presented at the Trauma Hemostasis and Oxygenation Research (THOR) Network Remote Damage Control Resuscitation (RCDR) Symposia from 2012 to 2017 (published 2013-2018). Further analysis was performed on the affiliations of conference attendees who attended from the years of 2012 to 2017. STUDY DESIGN AND METHODS: This project used normative and relative bibliometric measures and social network analysis to evaluate the performance and impact of 100 peer-reviewed publications presented at the Trauma Hemostasis and Oxygenation Research (THOR) Network RDCR Symposia from 2012 to 2017. Publication and citation data were from Elsevier Scopus, a bibliographic citation database. Metrics from Elsevier SciVal were selected for the project to normalize for group size, year of publication, and document type. A six-year period of publications presented at the Symposia, published from 2013 to 2018, was selected for analysis. The publication and citation data were further analyzed using Elsevier SciVal and the iCite database from the National Institutes of Health Office of Portfolio Analysis. Sci2, VOSviewer, and Gephi were used for social network analyses and visualization. RESULTS: The 100 publications presented at the Trauma Hemostasis and Oxygenation Research (THOR) Network Remote Damage Control Resuscitation (RCDR) Symposia from 2012 to 2017 demonstrate reach and influence beyond the authors of the THOR publications or the THOR attendees. Citations to the THOR publications were published in 10 languages and 313 unique journals, with author affiliations from 62 countries. Citation metrics for the THOR publications exceed global averages with 65% of the THOR publications being in the 25% citation percentiles. When benchmarking the THOR publications using six homogenous comparator groups, the THOR publications demonstrate higher citation metrics than any of the comparator groups with more citations per publication, a higher average of cited publications, higher FWCI and outputs in the top citation percentiles among the six groups. The Office of Portfolio Analysis (OPA) iCite database was used to calculate potential to translate for the THOR publications with 57 of the THOR publications cited by clinical articles with an average approximate potential to translate score of 65.3%. CONCLUSIONS: The value of international groups with sharing of research and knowledge are instrumental in enhancing the uptake for best practices for in medicine and treatment of hemorrhagic shock resuscitation. The use of bibliometric methods and network analyses, along with benchmarking, demonstrated reach and impact beyond the THOR Network. Limitations include use of a single source for analysis of publication and citation; and that publication data alone does not provide a full overview of research performance. Despite these limitations, bibliometric methods, social network analyses, and benchmarking can help centers better understand their impact.


Assuntos
Bibliometria , Análise de Rede Social , Bases de Dados Factuais , Hemostasia , Humanos
8.
Transfusion ; 62 Suppl 1: S12-S21, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35730720

RESUMO

BACKGROUND: Mass casualty incidents (MCIs) create an immediate surge in blood product demand. We hypothesize local inventories in major U.S. cities would not meet this demand. STUDY DESIGN AND METHODS: A simulated blast in a large crowd estimated casualty numbers. Ideal resuscitation was defined as equal amounts of red blood cells (RBCs), plasma, platelets, and cryoprecipitate. Inventory was prospectively collected from six major U.S. cities at six time points between January and July 2019. City-wide blood inventories were classified as READY (>1 U/injured survivor), DEFICIENT (<10 U/severely injured survivor), or RISK (between READY and DEFICIENT), before and after resupply from local distribution centers (DC), and features of DEFICIENT cities were identified. RESULTS: The simulated blast resulted in 2218 injured survivors including 95 with severe injuries. Balanced resuscitation would require between 950 and 2218 units each RBC, plasma, platelets and cryoprecipitate. Inventories in 88 hospitals/health systems and 10 DCs were assessed. Of 36 city-wide surveys, RISK inventories included RBCs (n = 16; 44%), plasma (n = 24; 67%), platelets (n = 6; 17%), and cryoprecipitate (n = 22; 61%) while DEFICIENT inventories included platelets (n = 30; 83%) and cryoprecipitate (n = 12; 33%). Resupply shifted most RBC and plasma inventories to READY, but some platelet and cryoprecipitate inventories remained at RISK (n = 24; 67% and n = 12; 33%, respectively) or even DEFICIENT (n = 11; 31% and n = 6; 17%, respectively). Cities with DEFICIENT inventories were smaller (p <.001) with fewer blood products per trauma bed (p <.001). DISCUSSION: In this simulated blast event, blood product demand exceeded local supply in some major U.S. cities. Options for closing this gap should be explored to optimize resuscitation during MCIs.


Assuntos
Incidentes com Feridos em Massa , Ferimentos e Lesões , Cidades , Humanos , Plasma , Ressuscitação/métodos
9.
Prehosp Emerg Care ; 26(6): 863-875, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34669564

RESUMO

The evidence for the lifesaving benefits of prehospital transfusions is increasing. As such, emergency medical services (EMS) might increasingly become interested in providing this important intervention. While a few EMS and air medical agencies have been providing exclusively red blood cell (RBC) transfusions to their patients for many years, transfusing plasma in addition to the RBCs, or simply using low titer group O whole blood (LTOWB) in place of two separate components, will be a novel experience for many services. The recommendations presented in this document were created by the Trauma, Hemostasis and Oxygenation Research (THOR)-AABB (formerly known as the American Association of Blood Banks) Working Party, and they are intended to provide a framework for implementing prehospital blood transfusion programs in line with the best available evidence. These recommendations cover all aspects of such a program including storing, transporting, and transfusing blood products in the prehospital phase of hemorrhagic resuscitation.


Assuntos
Serviços Médicos de Emergência , Ferimentos e Lesões , Humanos , Transfusão de Sangue , Ressuscitação , Hemorragia/terapia , Hemostasia
10.
PLoS Med ; 18(12): e1003872, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34928960

RESUMO

BACKGROUND: The United States (US) Expanded Access Program (EAP) to coronavirus disease 2019 (COVID-19) convalescent plasma was initiated in response to the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19. While randomized clinical trials were in various stages of development and enrollment, there was an urgent need for widespread access to potential therapeutic agents. The objective of this study is to report on the demographic, geographical, and chronological characteristics of patients in the EAP, and key safety metrics following transfusion of COVID-19 convalescent plasma. METHODS AND FINDINGS: Mayo Clinic served as the central institutional review board for all participating facilities, and any US physician could participate as a local physician-principal investigator. Eligible patients were hospitalized, were aged 18 years or older, and had-or were at risk of progression to-severe or life-threatening COVID-19; eligible patients were enrolled through the EAP central website. Blood collection facilities rapidly implemented programs to collect convalescent plasma for hospitalized patients with COVID-19. Demographic and clinical characteristics of all enrolled patients in the EAP were summarized. Temporal patterns in access to COVID-19 convalescent plasma were investigated by comparing daily and weekly changes in EAP enrollment in response to changes in infection rate at the state level. Geographical analyses on access to convalescent plasma included assessing EAP enrollment in all national hospital referral regions, as well as assessing enrollment in metropolitan areas and less populated areas that did not have access to COVID-19 clinical trials. From April 3 to August 23, 2020, 105,717 hospitalized patients with severe or life-threatening COVID-19 were enrolled in the EAP. The majority of patients were 60 years of age or older (57.8%), were male (58.4%), and had overweight or obesity (83.8%). There was substantial inclusion of minorities and underserved populations: 46.4% of patients were of a race other than white, and 37.2% of patients were of Hispanic ethnicity. Chronologically and geographically, increases in the number of both enrollments and transfusions in the EAP closely followed confirmed infections across all 50 states. Nearly all national hospital referral regions enrolled and transfused patients in the EAP, including both in metropolitan and in less populated areas. The incidence of serious adverse events was objectively low (<1%), and the overall crude 30-day mortality rate was 25.2% (95% CI, 25.0% to 25.5%). This registry study was limited by the observational and pragmatic study design that did not include a control or comparator group; thus, the data should not be used to infer definitive treatment effects. CONCLUSIONS: These results suggest that the EAP provided widespread access to COVID-19 convalescent plasma in all 50 states, including for underserved racial and ethnic minority populations. The study design of the EAP may serve as a model for future efforts when broad access to a treatment is needed in response to an emerging infectious disease. TRIAL REGISTRATION: ClinicalTrials.gov NCT#: NCT04338360.


Assuntos
COVID-19/terapia , Ensaios de Uso Compassivo/métodos , Necessidades e Demandas de Serviços de Saúde/estatística & dados numéricos , Sistemas de Distribuição no Hospital/organização & administração , Sistema de Registros , Reação Transfusional/complicações , Reação Transfusional/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Minorias Étnicas e Raciais , Feminino , Humanos , Imunização Passiva/efeitos adversos , Imunização Passiva/métodos , Pacientes Internados , Masculino , Área Carente de Assistência Médica , Pessoa de Meia-Idade , Pandemias , Segurança do Paciente , SARS-CoV-2 , Resultado do Tratamento , Estados Unidos , Soroterapia para COVID-19
11.
Int J Obes (Lond) ; 45(3): 525-534, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33144700

RESUMO

BACKGROUND: Weight-loss programmes often achieve short-term success though subsequent weight regain is common. The ability to identify predictive factors of regain early in the weight maintenance phase is crucial. OBJECTIVE: To investigate the associations between short-term weight variability and long-term weight outcomes in individuals engaged in a weight-loss maintenance intervention. METHODS: The study was a secondary analysis from The NoHoW trial, an 18-month weight maintenance intervention in individuals who recently lost ≥5% body weight. Eligible participants (n = 715, 64% women, BMI = 29.2 (SD 5.0) kg/m2, age = 45.8 (SD 11.5) years) provided body-weight data by smart scale (Fitbit Aria 2) over 18 months. Variability in body weight was calculated by linear and non-linear methods over the first 6, 9 and 12 weeks. These estimates were used to predict percentage weight change at 6, 12, and 18 months using both crude and adjusted multiple linear regression models. RESULTS: Greater non-linear weight variability over the first 6, 9 and 12 weeks was associated with increased subsequent weight in all comparisons; as was greater linear weight variability measured over 12 weeks (up to AdjR2 = 4.7%). Following adjustment, 6-week weight variability did not predict weight change in any model, though greater 9-week weight variability by non-linear methods was associated with increased body-weight change at 12 (∆AdjR2 = 1.2%) and 18 months (∆AdjR2 = 1.3%) and by linear methods at 18 months (∆AdjR2 = 1.1%). Greater non-linear weight variability measured over 12 weeks was associated with increased weight at 12 (∆AdjR2 = 1.4%) and 18 (∆AdjR2 = 2.2%) months; and 12-week linear variability was associated with increased weight at 12 (∆AdjR2 = 2.1%) and 18 (∆AdjR2 = 3.6%) months. CONCLUSION: Body-weight variability over the first 9 and 12 weeks of a weight-loss maintenance intervention weakly predicted increased weight at 12 and 18 months. These results suggest a potentially important role in continuously measuring body weight and estimating weight variability.


Assuntos
Manutenção do Peso Corporal/fisiologia , Redução de Peso/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
Transfusion ; 61(1): 303-312, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33098328

RESUMO

Due to circumstances such as increased demand and an aging donor pool, the likelihood of critical platelet shortages is increasing. The platelet supply could be improved through the expansion of the donor pool, the identification and sustained utilization of high-quality donors, and changes in component processing and storage that result in a longer platelet shelf-life. Refrigerated platelets, stored at 1° to 6°C, have the potential to improve patient safety by decreasing the risk of bacterial contamination while concurrently allowing for a longer storage period (eg, 14 days) and improved hemostatic effectiveness in actively bleeding patients. An approach utilizing remuneration of apheresis platelet donors combined with pathogen reduction of the platelet components could be used as a means to increase the donor pool and identify and sustain safe, reliable, high-quality donors. Remuneration might provide an incentive for underutilized populations (eg, individuals <30 years old) to enter the apheresis platelet donor population resulting in a significant expansion of the platelet donor pool. Over time, approaches such as the use of refrigerated platelets, platelet donor remuneration, and the application of pathogen reduction technology, might serve to attract a large, reliable, and safe donor base that provides platelet collections with high yields, longer shelf-lives and, excellent hemostatic function.


Assuntos
Plaquetas/citologia , Segurança do Sangue/normas , Transfusão de Plaquetas/estatística & dados numéricos , Doadores de Tecidos/provisão & distribuição , Adulto , Idoso , Preservação de Sangue/métodos , Preservação de Sangue/normas , Segurança do Sangue/estatística & dados numéricos , Criopreservação/métodos , Criopreservação/normas , Desinfecção/métodos , Desinfecção/normas , Humanos , Pessoa de Meia-Idade , Segurança do Paciente , Plaquetoferese/economia , Plaquetoferese/métodos , Remuneração , Tecnologia/métodos , Doadores de Tecidos/estatística & dados numéricos
13.
Transfusion ; 61(11): 3129-3138, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34469010

RESUMO

BACKGROUND: The SARS-CoV-2 pandemic disrupted hospital operations, affected the blood supply, and challenged the health care system to develop new therapeutic options, including convalescent plasma (CCP). The aim of this study is to describe and analyze blood supply fluctuations and the use of convalescent plasma in 2020. METHODS: AABB distributed a weekly and biweekly questionnaire through email to hospital-based members (HBM). RESULTS: The survey was sent to 887 HBM with 479 unique respondents, most of the hospitals served pediatric and adult patients, and all states of the country participated, except Idaho and Vermont. Fifty four percent of HBM reported increased wastage in the early phase of the pandemic (May), which decreased to 4% by the end of June and throughout the rest of the year. The majority of HBM reported receiving alerts from their blood suppliers reporting blood shortages throughout the year. During March and April, only 12% of HBM were performing elective surgical procedures. The top reasons to delay procedures were: bed availability (28%); COVID-19 caseload (23%; and blood availability (19%). By mid-April, 42% HBM had transfused CCP and reported >24 h delay in getting the units; the vast majority obtained CCP using the Expanded Access Protocol, and later, the Emergency Use Authorization. HBM consistently prioritized the most severe patients to receive CCP, but the proportion of severely ill recipients fell from 52% to 37% between May and October, with an increase from 5% to 21% of HBM providing CCP transfusion early in the course of the disease. DISCUSSION: Blood utilization and availability fluctuated during the pandemic. The fluctuations appeared to be related to the number of COVID-19 in the community. The use and regulatory landscape of CCP rapidly evolved over the first 8 months of the pandemic.


Assuntos
Transfusão de Sangue , COVID-19/epidemiologia , Pandemias , SARS-CoV-2 , Inquéritos e Questionários , Adulto , Feminino , Humanos , Masculino
14.
Transfusion ; 61(1): 72-77, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33029791

RESUMO

BACKGROUND: The COVID-19 pandemic has placed great strain on blood resources. In an effort to extend platelet (PLT) shelf life and minimize waste, our institution transitioned room temperature to cold-stored PLTs for administration to bleeding patients. STUDY DESIGN AND METHODS: We describe the administrative and technical processes involved in transitioning room temperature PLTs to cold storage in April 2020. Additionally, we describe the clinical utilization of cold-stored PLTs in the first month of this practice change, with a focus on changes in PLT counts after transfusion, hemostasis, and safety outcomes. RESULTS: A total of 61 cold-stored PLT units were transfused to 40 bleeding patients, with a median (interquartile range [IQR]) of 1 (1-2) units per patient. The median age was 68 (59-73) years; 58% male. Median pretransfusion and posttransfusion PLTs counts were 88 (67-109) and 115 (93-145). A total of 95% of transfusions were administered in the operating room: 57% cardiac surgery, 20% vascular surgery, 8% general surgery, and 5% solid organ transplantation. Hemostasis was deemed to be adequate in all cases after transfusion. There were no transfusion reactions. One patient (3%) experienced a fever and infection within 5 days of transfusion, which was unrelated to transfusion. Median (IQR) hospital length of stay was 8.5 (6-17) days. Two patients (5%) died in the hospital of complications not related to transfusion. CONCLUSION: Cold-stored PLT utilization was associated with adequate hemostasis and no overt signal for patient harm. Conversion from room temperature to cold-stored PLTs may be one method of reducing waste in times of scarce blood inventories.


Assuntos
Plaquetas , Preservação de Sangue/métodos , COVID-19/terapia , Transfusão de Plaquetas/métodos , Idoso , Feminino , Hemorragia/terapia , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/imunologia , SARS-CoV-2/patogenicidade , Temperatura
15.
Transfusion ; 61(1): 52-56, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33078463

RESUMO

Platelet (PLT) transfusions are an important component of hemostatic resuscitation. The AABB has published several guidelines recommending that PLT units should not be infused through blood warming devices. STUDY DESIGN AND METHODS: Thirty-one units of hospital blood bank apheresis PLTs were obtained. PLT-rich plasma (PRP) aggregometry and thromboelastography (TEG) were performed on the unit samples before and after the units were infused through a Ranger blood/fluid warming device. RESULTS: There were no differences in any of the aggregometry results before and after infusion of the PLTs through the blood warmer (all P > .32). There was a significant reduction in the TEG maximum amplitude (MA) of 69.8 ± 7.9 mm before and 66.0 ± 8.8 mm after (P < .001) infusion of the PLTs through the blood warmer and α angle 61.8 ± 9.4° before and 59.3 ± 8.2° after (P = .044) infusion of the PLTs through the blood warmer, although both mean values were within normal range for the TEG and not clinically significant. There were very good correlations of aggregometry and TEG results before and after infusion of the PLTs through the blood warmer device. CONCLUSION: This study did not demonstrate significant deleterious effect on PLT function from infusing apheresis PLT units through a blood warming device by PRP aggregometry. We did detect a statistically significant-but not clinically significant-reduction in TEG MA and α angle. The prohibition of transfusing PLT units though the Ranger blood warming device is not indicated.


Assuntos
Plaquetas , Transfusão de Plaquetas/métodos , Ressuscitação/métodos , Bancos de Sangue , Plaquetas/química , Plaquetas/metabolismo , Preservação de Sangue , Humanos , Testes de Função Plaquetária , Transfusão de Plaquetas/instrumentação , Temperatura , Tromboelastografia
16.
Transfusion ; 61(9): 2668-2676, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34227689

RESUMO

BACKGROUND: Although the safety and therapeutic efficacy of COVID-19 convalescent plasma (CCP) has been extensively evaluated, the safety of CCP donation has not been explored in a multi-institutional context. STUDY DESIGN AND METHODS: Nine blood collection organizations (BCOs) participated in a multi-institutional donor hemovigilance effort to assess the safety of CCP donation. Donor adverse events (DAEs) were defined according to the Standard for Surveillance of Complications Related to Blood Donation, and severity was assessed using the severity grading tool. Multivariate analysis was performed to determine attributes associated with DAE severity. RESULTS: The overall DAE rate was 37.7 per 1000 donations. Repeat apheresis and apheresis-naïve donors experienced adverse event rates of 19.9 and 49.8 per 1000 donations, respectively. Female donors contributed 51.9% of CCP donations with a DAE rate of 49.4 per 1000 donations. The DAE rate for male donors was 27.4 per 1000 donations. Vasovagal reactions accounted for over half of all reported DAEs (51.1%). After adjustment, volume of CCP donated was associated with vasovagal reaction severity (odds ratio [OR] 6.5, 95% confidence interval [CI] 2.5-17.1). Donor age and donation history were also associated with DAE severity. Considerable differences in DAE types and rates were observed across the participating BCOs despite the use of standardized hemovigilance definitions. CONCLUSION: The safety of CCP donation appears comparable to that of conventional apheresis plasma donation with similar associated risk factors for DAE types and severity.


Assuntos
Doadores de Sangue , Segurança do Sangue , COVID-19/sangue , COVID-19/imunologia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/diagnóstico , COVID-19/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Vigilância em Saúde Pública , Estudos Retrospectivos , Índice de Gravidade de Doença , Estados Unidos/epidemiologia , Adulto Jovem
17.
Transfusion ; 61 Suppl 1: S313-S325, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34269450

RESUMO

BACKGROUND: The current global pandemic has created unprecedented challenges in the blood supply network. Given the recent shortages, there must be a civilian plan for massively bleeding patients when there are no blood products on the shelf. Recognizing that the time to death in bleeding patients is less than 2 h, timely resupply from unaffected locations is not possible. One solution is to transfuse emergency untested whole blood (EUWB), similar to the extensive military experience fine-tuned over the last 19 years. While this concept is anathema in current civilian transfusion practice, it seems prudent to have a vetted plan in place. METHODS AND MATERIALS: During the early stages of the 2020 global pandemic, a multidisciplinary and international group of clinicians with broad experience in transfusion medicine communicated routinely. The result is a planning document that provides both background information and a high-level guide on how to emergently deliver EUWB for patients who would otherwise die of hemorrhage. RESULTS AND CONCLUSIONS: Similar plans have been utilized in remote locations, both on the battlefield and in civilian practice. The proposed recommendations are designed to provide high-level guidance for experienced blood bankers, transfusion experts, clinicians, and health authorities. Like with all emergency preparedness, it is always better to have a well-thought-out and trained plan in place, rather than trying to develop a hasty plan in the midst of a disaster. We need to prevent the potential for empty shelves and bleeding patients dying for lack of blood.


Assuntos
Armazenamento de Sangue , Armazenamento de Sangue/métodos , Preservação de Sangue/métodos , Transfusão de Sangue/métodos , COVID-19/epidemiologia , Defesa Civil , Serviço Hospitalar de Emergência , Humanos , Pandemias
18.
Appetite ; 165: 105308, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34010725

RESUMO

Overweight and obesity remain serious public health concerns. Outcomes from community based commercial weight management programmes vary, relapse is common and drop out is high. Outcomes could be improved by better understanding experiences on these programmes. The aim of our study was to generate accounts of people's experience on a commercial weight-management program to identify what experiences were perceived as facilitating, and what posed risks, to programme effectiveness and compliance. We conducted individual, semi-structured interviews with eighteen Caucasian women (mean age 45.4y) who were members of nation-wide UK commercial, fee-paying, community weight management programme. Interview data was analysed via framework analysis. Participants' experiences indicated that the programme helped by triggering several intra- and interpersonal processes that catalysed change across psychological, physiological, dietary and behavioural areas of their life. Risks to program adherence and effectiveness spanned well-known risks such as self-regulation fatigue and the difficulty of recovering from negative self-criticism, as well as new factors such as the confusing nature of weight change, the relatively powerful impact of everyday events, and the difficulty in getting the balance right between personalised support vs. intrusion. The complexity of reported experiences challenges the linear, predictive pathways of change proposed by many health behaviour models of weight management. To improve effectiveness, programmes need to go well beyond behavioural and dietary support. It is recommended that community, commercial programmes educate people about the physiological and psychological tensions they will encounter, why people lose weight at different rates, the likelihood of weight relapse and strategies to manage these, including evidence-based support for managing self-criticism.


Assuntos
Obesidade , Percepção , Feminino , Humanos , Pessoa de Meia-Idade , Obesidade/prevenção & controle , Pesquisa Qualitativa , Fatores de Risco , Reino Unido
19.
Int J Obes (Lond) ; 44(7): 1577-1585, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31937906

RESUMO

BACKGROUND: An association between sleep and obesity has been suggested in several studies, but many previous studies relied on self-reported sleep and on BMI as the only adiposity measure. Moreover, a relationship between weight loss history and attained sleep duration has not been thoroughly explored. DESIGN: The study comprised of 1202 participants of the European NoHoW trial who had achieved a weight loss of ≥5% and had a BMI of ≥25 kg/m2 prior to losing weight. Information was available on objectively measured sleep duration (collected during 14 days), adiposity measures, weight loss history and covariates. Regression models were conducted with sleep duration as the explanatory variable and BMI, fat mass index (FMI), fat-free mass index (FFMI) and waist-hip ratio (WHR) as response variables. Analyses were conducted with 12-month weight loss, frequency of prior weight loss attempts or average duration of weight maintenance after prior weight loss attempts as predictors of measured sleep duration. RESULTS: After adjusting for physical activity, perceived stress, smoking, alcohol consumption, education, sex and age, sleep duration was associated to BMI (P < 0.001), with the highest BMI observed in the group of participants sleeping <6 h a day [34.0 kg/m2 (95% CI: 31.8-36.1)]. Less difference in BMI was detected between the remaining groups, with the lowest BMI observed among participants sleeping 8-<9 h a day [29.4 kg/m2 (95% CI: 28.8-29.9)]. Similar results were found for FMI (P = 0.008) and FFMI (P < 0.001). We found no association between sleep duration and WHR. Likewise, we found no associations between weight loss history and attained sleep duration. CONCLUSION: In an overweight population who had achieved a clinically significant weight loss, short sleep duration was associated with higher BMI, with similar associations for fat and lean mass. We found no evidence of association between weight loss history and attained sleep duration.


Assuntos
Adiposidade , Sono , Redução de Peso , Adulto , Índice de Massa Corporal , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/epidemiologia , Sobrepeso/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Relação Cintura-Quadril
20.
Br J Sports Med ; 54(6): 332-340, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30194221

RESUMO

OBJECTIVE: To determine the accuracy of wrist and arm-worn activity monitors' estimates of energy expenditure (EE). DATA SOURCES: SportDISCUS (EBSCOHost), PubMed, MEDLINE (Ovid), PsycINFO (EBSCOHost), Embase (Ovid) and CINAHL (EBSCOHost). DESIGN: A random effects meta-analysis was performed to evaluate the difference in EE estimates between activity monitors and criterion measurements. Moderator analyses were conducted to determine the benefit of additional sensors and to compare the accuracy of devices used for research purposes with commercially available devices. ELIGIBILITY CRITERIA: We included studies validating EE estimates from wrist-worn or arm-worn activity monitors against criterion measures (indirect calorimetry, room calorimeters and doubly labelled water) in healthy adult populations. RESULTS: 60 studies (104 effect sizes) were included in the meta-analysis. Devices showed variable accuracy depending on activity type. Large and significant heterogeneity was observed for many devices (I2 >75%). Combining heart rate or heat sensing technology with accelerometry decreased the error in most activity types. Research-grade devices were statistically more accurate for comparisons of total EE but less accurate than commercial devices during ambulatory activity and sedentary tasks. CONCLUSIONS: EE estimates from wrist and arm-worn devices differ in accuracy depending on activity type. Addition of physiological sensors improves estimates of EE, and research-grade devices are superior for total EE. These data highlight the need to improve estimates of EE from wearable devices, and one way this can be achieved is with the addition of heart rate to accelerometry. PROSPEROREGISTRATION NUMBER: CRD42018085016.


Assuntos
Acelerometria/instrumentação , Acelerometria/normas , Metabolismo Energético , Monitores de Aptidão Física/normas , Acelerometria/métodos , Atividades Cotidianas , Braço , Ciclismo/fisiologia , Desenho de Equipamento , Frequência Cardíaca/fisiologia , Humanos , Corrida/fisiologia , Comportamento Sedentário , Subida de Escada/fisiologia , Caminhada/fisiologia , Punho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA