Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Vasc Surg ; 73(2): 426-432.e2, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32640319

RESUMO

BACKGROUND: In-hospital and 30-day mortality rates of endovascular repair of thoracoabdominal aortic aneurysms shows a significant improvement over open surgery, although we are not seeing a significant difference at 1 year. We assess the hypothesis that a greater mural thrombus ratio within the aorta could function as an indicator of postoperative mortality. METHODS: The mural thrombus ratio and preoperative comorbidities of 100 consecutive patients from a single center undergoing endo-debranching between 2012 and 2019 were evaluated. Logistic regression, survival analysis, and decision tree methods were used to examine each variable's association with death at 1 year. RESULTS: At the time of analysis, 73 subjects had 1-year outcomes and adequate imaging to assess the parameters. At 1 year, the overall survival for all subjects was 71.2% (21 died, 52 survived). For patients with a favorable mural thrombus ratio (n = 36), the overall 1-year survival was 86.1% (5 died, 31 survived). The subjects with an unfavorable mural thrombus ratio (n = 37), had an overall 1 year survival of 56.8% (16 died, and 21 survived). The only preoperative mortality factor that was statistically significant between the subjects with an unfavorable mural thrombus ratio was age of the patient. The survival for subjects 75 years and older with an unfavorable mural thrombus ratio was 90% (one died, nine survived) vs only 44.4% survival for subjects less than 75 years with an unfavorable mural thrombus ratio (15 died, 12 survived). CONCLUSIONS: This study examined whether a patient's mural thrombus ratio may be an indicator of 1-year survival. These findings suggest that the combination of a patient's aortic mural thrombus ratio and age can function as a preoperative indicator of their underlying cardiac reserve. Identifying patients with low cardiac reserve and fitness to handle the increased cardiac demands owing to the physiologic response to extensive aortic stent grafting before undergoing aortic repair may allow for modification of preoperative patient counseling and postoperative care guidelines to better treat this patient population.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/mortalidade , Trombose/mortalidade , Fatores Etários , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aortografia , Implante de Prótese Vascular/efeitos adversos , Comorbidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
2.
J Vasc Surg ; 65(6): 1813-1819, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27693030

RESUMO

OBJECTIVE: This study proposes to establish a simulation-based technique for evaluating shear accumulation in stent grafts and to use the technique to assess the performance of a novel branched stent graft system. METHODS: Computational fluid dynamics models, with transient boundary conditions, particle injection, and rigid walls, simplifying assumptions were developed and used to evaluate the shear accumulation in various stent graft configurations with a healthy aorta as comparison. RESULTS: Shear streamlines are presented for the various configurations. Shear accumulation was also calculated for each configuration. The number of particles with shear accumulations >3.5 Pa-s for each configuration was compared with the shear accumulation values of commercially available mechanical aortic valves from the literature. CONCLUSIONS: The stent graft configuration with the diaphragm does have particles with shear accumulation >3.5 Pa-s. However, the percentage of particles with shear accumulation above 3.5 Pa-s is less than the two commercially available mechanical aortic valves, and more surprisingly, is smaller than in the healthy aorta.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Stents , Tromboembolia/etiologia , Aorta Torácica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Fluxo Pulsátil , Fluxo Sanguíneo Regional , Medição de Risco , Fatores de Risco , Estresse Mecânico , Tromboembolia/fisiopatologia
3.
J Vasc Surg ; 64(3): 788-96, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26209577

RESUMO

OBJECTIVE: This study examined the flow behavior of four stent graft configurations for endovascular repair of complex aneurysms of the descending aorta. METHODS: Computational fluid dynamics models with transient boundary conditions and rigid wall simplifying assumptions were developed and used with four distinct geometries to compare various near-wall hemodynamic parameters. RESULTS: Graphic plots for time-averaged wall shear stress, oscillating shear index, and relative residence time were presented and compared among the four stent graft configurations of interest. CONCLUSIONS: Abrupt 90° and 180° changes in stent geometry (particularly in the side branches) cause a high momentum change and thus increased flow separation and mixing, which has significant implications in blood flow characteristics near the wall. By comparison, longer bridging stents provide more gradual changes in momentum, thus allowing blood flow to develop before reaching the target vessel.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Stents , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Desenho de Prótese , Fluxo Sanguíneo Regional , Estresse Mecânico , Fatores de Tempo , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA