Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Transfusion ; 62(6): 1269-1279, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35510783

RESUMO

BACKGROUND: Blood centers have a dual mission to protect donors and patients; donor safety is paramount to maintaining an adequate blood supply. Elucidating donor factors associated with adverse reactions (AR) is critical to this mission. STUDY DESIGN/METHODS: A retrospective cohort analysis of whole blood donors from 2003 to 2020 was conducted at a single blood center in northern California. Adjusted odds ratios (AORs) with 95% CIs for ARs were estimated via multivariable logistic regression on demographics, donation history, and physical examination data. Where appropriate, Wilcoxon-Rank Sum and chi-squared tests were used to determine significance. RESULTS: First-time blood donors (FTD) exhibited a higher AR rate than repeat donors (4.4% vs. 1.9% p < .0001). When compared with FTDs without AR, FTDs with ARs (FT-AR) were less likely to return (30.0% vs. 47.3%, p < .0001), and, of those who returned, had a higher rate of reaction 20.2% versus 2.8% (p < .001). Factors found to be associated with FT-AR (younger age, increased heart rate, and higher diastolic blood pressure) still correlated positively with AR on return donation, but to a lower degree. FTD who potentially witnessed an AR had a lower return rate (44.6% vs. 47.3%, p = <.001) and donated fewer units (2.38 vs. 3.37, p < .001) when compared to FTD who did not witness an AR. CONCLUSION: The AR on FTD increases the AR likelihood of return donation. Longitudinal analysis shows that a time-based deferral policy targeted at FT-AR young donors can reduce the number of ARs while not dramatically impacting the blood supply.


Assuntos
Doadores de Sangue , Demência Frontotemporal , Estudos de Coortes , Humanos , Modelos Logísticos , Estudos Retrospectivos
2.
Transfusion ; 62(10): 2108-2116, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36052676

RESUMO

BACKGROUND: Bacterial contamination in platelets remain a major public health concern, which prompted the US Food and Drug Administration guidance for bacterial contamination mitigation. Pathogen reduction technology (PRT) is one mitigation strategy that has shown success in Europe over the last decade. Therefore, our center sought to transition from a dual system of bacterial culturing (BacT) and PRT to full PRT. METHODS: A 1 month pilot study was conducted to simulate 100% PRT conditions. Our center also collected baseline data on key platelet production metrics in the 4 months prior to 100% PRT and compared it to the 4 months post-implementation. RESULTS: The pilot study showed no statistical differences in split rate, proportion of low-yield products, or proportion of single, double, and triple collections. The only observed difference was an 11 min increase in the average duration of double collections. Our baseline versus post-implementation monitoring showed no difference in split rate, discard rate, percentage of low-yield units, and average yield of low yield units. Statistical differences were detected in the proportion of single, double, and triple collections, as well as the average yield of full dose products. Roughly 20% of our inventory consisted of low-yield products. DISCUSSION: With suitable mitigation strategies, transitioning to a full PRT inventory may result in higher net margins while not adversely affecting overall platelet production. A pilot study is a good way to project potential effects of switching from a dual BacT and PRT inventory to full PRT, and can be adopted by other centers aiming to make the transition.


Assuntos
Remoção de Componentes Sanguíneos , Plaquetas , Plaquetas/microbiologia , Europa (Continente) , Humanos , Projetos Piloto , Transfusão de Plaquetas , Tecnologia
3.
Transfusion ; 61(12): 3295-3302, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34796968

RESUMO

BACKGROUND: Several risk mitigation steps have improved the safety of platelets in regard to bacterial contamination, but this continues to be a concern today. A Food and Drug Administration (FDA) Guidance issued in December 2018 aims to further limit this risk. The guidance offers multiple pathways for compliance, and hospital blood banks will have to collaborate with blood donor centers to assess various factors before deciding which method is most appropriate for them. METHODS AND MATERIALS: Our institution considered several factors before moving forward with pathogen reduction technology. This included an assessment of platelet shelf-life, bacterial testing requirements, the efficacy of low-yield platelets, and managing a mixed platelet inventory. The decision to transition to pathogen-reduced platelets was associated with complex collection and processing limitations that resulted in either an increase in platelets that were over-concentrated or products with a low platelet yield. RESULTS: Through trials of various collection settings with unique target volumes and target platelet yields, our blood donor center was able to optimize the production. At the hospital end, this transition required a thorough review of low-yield platelet products and their clinical efficacy. Additionally, this implementation necessitated collaboration with clinical colleagues, comprehensive education, and training. CONCLUSIONS: Pathogen-reduced platelets would be the most efficient way for our institution to be compliant. This summary may serve as a roadmap for other institutions that are considering which FDA prescribed method to use and provide support for those that have decided on pathogen reduction technology but need to optimize their collections to best utilize low-yield products.


Assuntos
Plaquetas , Trombocitopenia , Bancos de Sangue , Plaquetas/microbiologia , Humanos , Transfusão de Plaquetas/métodos
4.
Transfusion ; 60(3): 544-552, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32034925

RESUMO

BACKGROUND: Determination of blood donor hemoglobin (Hb) levels is a pre-requisite to ensure donor safety and blood product quality. We aimed to identify Hb measurement practices across blood donation services and to what extent differences associate with low-Hb deferral rates. METHODS: An online survey was performed among Biomedical Excellence for Safer Transfusion (BEST) Collaborative members, extended with published data. Multivariable negative-binomial regression models were built to estimate adjusted associations of minimum donation intervals, Hb cut-offs (high, ≥13.5 g/dL in men or ≥ 12.5 g/dL in women, vs. lower values), iron monitoring (yes/no), providing or prescribing iron supplementation (yes/no), post-versus pre-donation Hb measurement and geographical location (Asian vs. rest), with low-Hb deferral rates. RESULTS: Data were included from 38 blood services. Low-Hb deferral rates varied from 0.11% to 8.81% among men and 0.84% to 31.85% among women. Services with longer minimum donation intervals had significantly lower deferral rates among both women (rate ratio, RR 0.53, 95%CI 0.33-0.84) and men (RR 0.53, 95%CI 0.31-0.90). In women, iron supplementation was associated with lower Hb deferral rates (RR 0.47, 95%CI 0.23-0.94). Finally, being located in Asia was associated with higher low-Hb deferral rates; RR 9.10 (95%CI 3.89-21.27) for women and 6.76 (95%CI 2.45-18.68) for men. CONCLUSION: Differences in Hb measurement and eligibility criteria, particularly longer donation intervals and iron supplementation in women, are associated with variations in low-Hb deferral rates. These insights could help improve both blood donation service efficiency and donor care.


Assuntos
Doadores de Sangue/estatística & dados numéricos , Hemoglobinas/metabolismo , Transfusão de Sangue/métodos , Seleção do Doador , Feminino , Testes Hematológicos , Humanos , Ferro/metabolismo , Inquéritos e Questionários , Fatores de Tempo
5.
Transfusion ; 49(10): 2040-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19538430

RESUMO

BACKGROUND: Blood centers and hospital transfusion services are challenged with maintaining an adequate platelet (PLT) inventory to minimize the number of outdated units without risking a major shortage. A novel approach to inventory management was established at our institution through a collaboration between the Stanford University Medical Center (SUMC) Transfusion Service, the Stanford Blood Center (SBC), and the Department of Management Science and Engineering. STUDY DESIGN AND METHODS: An analysis of the supply chain performance between SBC and SUMC Transfusion Service was performed. First, the interaction between processes, such as blood collection, rotation, and inventory management, was studied. Second, changes were implemented based on the recommendations from the analysis team. Finally, a postanalysis was performed reflecting on the improvement of the operations between SUMC and SBC. RESULTS: A comprehensive data analysis of the PLT supply chain allowed the identification of three series of improvements to be implemented: 1) on SBC's PLT collection, 2) on SBC's rotation process, and 3) on the PLT inventory management policy at SUMC. A postimplementation analysis showed a reduction in the overall PLT outdate rate from 19% in the first quarter of 2006, down to 9% in the third quarter of 2008. CONCLUSION: A multidisciplinary effort among SUMC Transfusion Service, SBC, and experts in supply chain management resulted in a process improvement, which reduced the rate of PLT outdate at both SBC and SUMC Transfusion Service down to 9%, with a significant cost reduction of more than half a million dollars per year.


Assuntos
Bancos de Sangue , Comportamento Cooperativo , Hospitais , Transfusão de Plaquetas , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA