Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37874020

RESUMO

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Seguimentos , Readmissão do Paciente , Insuficiência Cardíaca/etiologia
3.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

4.
Eur Heart J ; 44(33): 3181-3195, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37350747

RESUMO

AIMS: The safety and efficacy of transcatheter aortic valve replacement (TAVR) with contemporary balloon expandable transcatheter valves in patients with cardiogenic shock (CS) remain largely unknown. In this study, the TAVRs performed for CS between June 2015 and September 2022 using SAPIEN 3 and SAPIEN 3 Ultra bioprosthesis from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were analysed. METHODS AND RESULTS: CS was defined as: (i) coding of CS within 24 h on Transcatheter Valve Therapy Registry form; and/or (ii) pre-procedural use of inotropes or mechanical circulatory support devices and/or (iii) cardiac arrest within 24 h prior to TAVR. The control group was comprised of all the other patients undergoing TAVR. Baseline characteristics, all-cause mortality, and major complications at 30-day and 1-year outcomes were reported. Landmark analysis was performed at 30 days post-TAVR. Cox-proportional multivariable analysis was performed to determine the predictors of all-cause mortality at 1 year. A total of 309 505 patients underwent TAVR with balloon-expandable valves during the study period. Of these, 5006 patients presented with CS prior to TAVR (1.6%). The mean Society of Thoracic Surgeons score was 10.76 ± 10.4. The valve was successfully implanted in 97.9% of patients. Technical success according to Valve Academic Research Consortium-3 criteria was 94.5%. In a propensity-matched analysis, CS was associated with higher in-hospital (9.9% vs. 2.7%), 30-day (12.9% vs. 4.9%), and 1-year (29.7% vs. 22.6%) mortality compared to the patients undergoing TAVR without CS. In the landmark analysis after 30 days, the risk of 1-year mortality was similar between the two groups [hazard ratio (HR) 1.07, 95% confidence interval (CI) 0.95-1.21]. Patients who were alive at 1 year noted significant improvements in functional class (Class I/II 89%) and quality of life (ΔKCCQ score +50). In the multivariable analysis, older age (HR 1.02, 95% CI 1.02-1.03), peripheral artery disease (HR 1.25, 95% CI 1.06-1.47), prior implantation of an implantable cardioverter-defibrillator (HR 1.37, 95% CI 1.07-1.77), patients on dialysis (HR 2.07, 95% CI 1.69-2.53), immunocompromised status (HR 1.33, 95% CI 1.05-1.69), New York Heart Association class III/IV symptoms (HR 1.50, 95% CI 1.06-2.12), lower aortic valve mean gradient, lower albumin levels, lower haemoglobin levels, and lower Kansas City Cardiomyopathy Questionnaire scores were independently associated with 1-year mortality. CONCLUSION: This large observational real-world study demonstrates that the TAVR is a safe and effective treatment for aortic stenosis patients presenting with CS. Patients who survived the first 30 days after TAVR had similar mortality rates to those who were not in CS.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Estados Unidos , Substituição da Valva Aórtica Transcateter/métodos , Choque Cardiogênico , Qualidade de Vida , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Fatores de Risco
5.
Catheter Cardiovasc Interv ; 102(1): 145-154, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37178388

RESUMO

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (M-TEER) is an effective option for treatment of mitral regurgitation (MR). We previously reported favorable 2-year outcomes for the PASCAL transcatheter valve repair system. OBJECTIVES: We report 3-year outcomes from the multinational, prospective, single-arm CLASP study with analysis by functional MR (FMR) and degenerative MR (DMR). METHODS: Patients with core-lab determined MR ≥ 3+ were deemed candidates for M-TEER by the local heart team. Major adverse events were assessed by an independent clinical events committee to 1 year and by sites thereafter. Echocardiographic outcomes were evaluated by the core laboratory to 3 years. RESULTS: The study enrolled 124 patients, 69% FMR; 31% DMR (60% NYHA class III-IVa, 100% MR ≥ 3+). The 3-year Kaplan-Meier estimate for survival was 75% (66% FMR; 92% DMR) and freedom from heart failure hospitalization (HFH) was 73% (64% FMR; 91% DMR), with 85% reduction in annualized HFH rate (81% FMR; 96% DMR) (p < 0.001). MR ≤ 2+ was achieved and maintained in 93% of patients (93% FMR; 94% DMR) and MR ≤ 1+ in 70% of patients (71% FMR; 67% DMR) (p < 0.001). The mean left ventricular end-diastolic volume (181 mL at baseline) decreased progressively by 28 mL [p < 0.001]. NYHA class I/II was achieved in 89% of patients (p < 0.001). CONCLUSIONS: The 3-year results from the CLASP study demonstrated favorable and durable outcomes with the PASCAL transcatheter valve repair system in patients with clinically significant MR. These results add to the growing body of evidence establishing the PASCAL system as a valuable therapy for patients with significant symptomatic MR.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
6.
Am Heart J ; 243: 92-102, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34587510

RESUMO

BACKGROUND: The SMall Annuli Randomized To Evolut or SAPIEN (SMART) Trial was designed to compare the performance of the two most widely available commercial transcatheter aortic valve replacement (TAVR) devices in patients with symptomatic severe native aortic stenosis with a small aortic valve annulus undergoing transfemoral TAVR. Patients with small aortic valve annuli are typically female and are often underrepresented in clinical trials. METHODS: The SMART Trial is an international, prospective, multi-center, randomized controlled, post-market trial. The trial will be conducted in approximately 700 subjects at approximately 90 sites globally. Inclusion criteria include severe aortic stenosis, aortic valve annulus area of ≤430 mm2 based on multi-detector computed tomography, and appropriate anatomy for both the Medtronic Evolut PRO/PRO+ self-expanding and Edwards SAPIEN 3/3 Ultra balloon-expandable devices. The primary clinical outcome composite endpoint is defined as mortality, disabling stroke or heart failure rehospitalization at 12 months. The co-primary valve function composite endpoint is defined as bioprosthetic valve dysfunction at 12 months which includes hemodynamic structural valve dysfunction, defined as a mean gradient ≥20 mmHg, non-structural valve dysfunction, defined as severe prothesis-patient mismatch or ≥moderate aortic regurgitation, thrombosis, endocarditis, and aortic valve re-intervention. Powered secondary endpoints will be assessed hierarchically. CONCLUSIONS: The SMART trial will be the largest head-to-head comparative trial of transfemoral TAVR using the two most widely available contemporary TAVR devices in the setting of small aortic annuli and the largest trial to enroll primarily women. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov, Unique identifier: NCT04722250.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 99(3): 906-914, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34569695

RESUMO

BACKGROUND: There is a paucity of real-world data regarding the temporal trends and outcomes of trans-septal transcatheter mitral valve replacement (TS-TMVR) in the United States (US). METHODS: We queried the Nationwide Readmissions Database (October 2015 to December 2018) for patients undergoing TS-TMVR procedures. We reported the temporal trends in the utilization, in-hospital outcomes and 30-day readmissions after TS-TMVR. The main study outcome was in-hospital mortality. RESULTS: There was an increase in the number of TS-TMVR procedures over time (48 in 2015 vs. 978 in 2018, Ptrend < 0.001), with a notable increase in the proportion of women (Ptrend  = 0.04) and the prevalence of diabetes (Ptrend  = 0.03). There was an increase in the number of centers performing TS-TMVR (21 in 2015 vs. 164 in 2018, Ptrend < 0.001). The overall in-hospital mortality was 7.2% with no change over time (6.3% in 2015 vs. to 5.2% in 2018, Ptrend  = 0.67). There was no change in the frequency of in-hospital complications after TS-TMVR; however, the median length of stay has decreased over time. The overall 30-day readmission rate was 17.8%, with no change during the study years. The most frequent cause for 30-day readmission after TS-TMVR was acute heart failure followed by bleeding and infection-related complications. Prior coagulopathy and small-sized hospitals were independently associated with higher in-hospital mortality and 30-day readmissions. CONCLUSION: This nationwide observational analysis of real-world data showed an increase in the number of TS-TMVR procedures over time, which is now performed at a greater number of centers. There was no change in the rate of in-hospital mortality, complications or 30-day readmissions; but a significant reduction in the length of hospital stay over time was noted. As the number of TS-TMVR continue to expand, these data provide a perspective on the early experience with this procedure.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Readmissão do Paciente , Resultado do Tratamento , Estados Unidos/epidemiologia
8.
Catheter Cardiovasc Interv ; 98(5): 904-913, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34398509

RESUMO

The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.


Assuntos
Cardiologistas , Cardiologia , Cardiopatias Congênitas , Angiografia , Humanos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 96(5): 997-1005, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32767717

RESUMO

OBJECTIVES: We sought to determine the effect of COVID-19 related reduction in elective cardiac procedures and acute coronary syndrome presentations on interventional cardiology (IC) training. BACKGROUND: The COVID-19 pandemic has significantly disrupted healthcare in the United States, including cardiovascular services. The impact of COVID-19 on IC fellow training in the United States has not been assessed. METHODS: The Society for Cardiovascular Angiography and Interventions (SCAI) surveyed IC fellows training in both accredited and advanced non-accredited programs, as well as their program directors (PD). RESULTS: Responses were received from 135 IC fellows and 152 PD. All respondents noted reductions in procedural volumes beginning in March 2020. At that time, only 43% of IC fellows had performed >250 PCI. If restrictions were lifted by May 15, 2020 78% of IC fellows believed they would perform >250 PCI, but fell to only 70% if restrictions persisted until the end of the academic year. 49% of IC fellows felt that their procedural competency was impaired by COVID-19, while 97% of PD believed that IC fellows would be procedurally competent at the end of their training. Most IC fellows (65%) noted increased stress at work and at home, and many felt that job searches and/or existing offers were adversely affected by the pandemic. CONCLUSION: The COVID-19 pandemic has substantially affected IC training in the United States, with many fellows at risk of not satisfying current program procedural requirements. These observations support a move to review current IC program requirements and develop mitigation strategies to supplement gaps in education related to reduced procedural volume.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Bolsas de Estudo/organização & administração , Internato e Residência/organização & administração , Intervenção Coronária Percutânea/educação , Pneumonia Viral/epidemiologia , Cirurgia Torácica/educação , Adulto , COVID-19 , Competência Clínica , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , SARS-CoV-2 , Estados Unidos
10.
Catheter Cardiovasc Interv ; 96(3): 659-663, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32251546

RESUMO

The coronavirus disease-2019 (COVID-19) pandemic has strained health care resources around the world, causing many institutions to curtail or stop elective procedures. This has resulted in an inability to care for patients with valvular and structural heart disease in a timely fashion, potentially placing these patients at increased risk for adverse cardiovascular complications, including CHF and death. The effective triage of these patients has become challenging in the current environment, as clinicians have had to weigh the risk of bringing susceptible patients into the hospital environment during the COVID-19 pandemic against the risk of delaying a needed procedure. In this document, the authors suggest guidelines for how to triage patients in need of structural heart disease interventions and provide a framework for how to decide when it may be appropriate to proceed with intervention despite the ongoing pandemic. In particular, the authors address the triage of patients in need of transcatheter aortic valve replacement and percutaneous mitral valve repair. The authors also address procedural issues and considerations for the function of structural heart disease teams during the COVID-19 pandemic.


Assuntos
Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Infecções por Coronavirus/epidemiologia , Cardiopatias/cirurgia , Pandemias/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Guias de Prática Clínica como Assunto , Triagem/normas , COVID-19 , Procedimentos Cirúrgicos Cardíacos/métodos , Cardiologia/métodos , Cardiologia/normas , Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Feminino , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Saúde Ocupacional/estatística & dados numéricos , Pandemias/prevenção & controle , Segurança do Paciente , Pneumonia Viral/prevenção & controle , Sociedades Médicas , Triagem/estatística & dados numéricos , Estados Unidos
11.
Catheter Cardiovasc Interv ; 96(3): 586-597, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32212409

RESUMO

The novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is highly infectious, carries significant morbidity and mortality, and has rapidly resulted in strained health care system and hospital resources. In addition to patient-related care concerns in infected individuals, focus must also relate to diminishing community spread, protection of staff, case selection, and concentration of resources. The current document based on available data and consensus opinion addresses appropriate catheterization laboratory preparedness for treating these patients, including procedure-room readiness to minimize external contamination, safe donning and doffing of personal protective equipment (PPE) to eliminate risk to staff, and staffing algorithms to minimize exposure and maximize team availability. Case selection and management of both emergent and urgent procedures are discussed in detail, including procedures that may be safely deferred or performed bedside.


Assuntos
Cateterismo Cardíaco/estatística & dados numéricos , Angiografia Coronária/estatística & dados numéricos , Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Guias de Prática Clínica como Assunto/normas , COVID-19 , Cateterismo Cardíaco/normas , Cardiologia , Angiografia Coronária/métodos , Infecções por Coronavirus/epidemiologia , Feminino , Mortalidade Hospitalar , Humanos , Laboratórios Hospitalares , Liderança , Masculino , Mentores , Pandemias/estatística & dados numéricos , Equipamento de Proteção Individual/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Sociedades Médicas , Análise de Sobrevida , Estados Unidos
12.
Catheter Cardiovasc Interv ; 96(1): 145-155, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32061033

RESUMO

Evidence-based recommendations for clinical practice are intended to help health care providers and patients make decisions, minimize inappropriate practice variation, promote effective resource use, improve clinical outcomes, and direct future research. The Society for Cardiovascular Angiography and Interventions (SCAI) has been engaged in the creation and dissemination of clinical guidance documents since the 1990s. These documents are a cornerstone of the society's education, advocacy, and quality improvement initiatives. The publications committee is charged with oversight of SCAI's clinical documents program and has created this manual of standard operating procedures to ensure consistency, methodological rigor, and transparency in the development and endorsement of the society's documents. The manual is intended for use by the publications committee, document writing groups, external collaborators, SCAI representatives, peer reviewers, and anyone seeking information about the SCAI documents program.


Assuntos
Comitês Consultivos/normas , Angiografia/normas , Cateterismo Cardíaco/normas , Procedimentos Endovasculares/normas , Manuais como Assunto/normas , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Medicina Baseada em Evidências/normas , Humanos , Redação/normas
13.
Catheter Cardiovasc Interv ; 96(6): 1258-1265, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32840956

RESUMO

The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.


Assuntos
Cateterismo Cardíaco/tendências , Cardiologia/tendências , Angiografia Coronária/tendências , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Intervenção Coronária Percutânea/tendências , Difusão de Inovações , Cardiopatias/fisiopatologia , Humanos
14.
Curr Cardiol Rep ; 22(7): 50, 2020 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-32500412

RESUMO

PURPOSE OF REVIEW: The goal of the paper is to highlight the importance of procedural planning and patient selection when using the MitraClip device in treating severe mitral regurgitation (MR). RECENT FINDINGS: Following the recent results of the COAPT trial and FDA approval for functional MR patients, the indications for mitral clip are continuing to expand. Because of this, mitral stenosis from mitral clip can become a problem if the appropriate patients are not selected. Proper valve imaging, utilizing 3D transesophageal echocardiography to identify the pathology, is important to prevent iatrogenic mitral stenosis. In the unfortunate event of severe mitral stenosis as a result of the MitraClip device, surgery is the only treatment.


Assuntos
Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Valva Mitral/diagnóstico por imagem , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Humanos , Insuficiência da Valva Mitral/terapia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/terapia , Resultado do Tratamento
15.
J Interv Cardiol ; 31(1): 68-73, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29285803

RESUMO

OBJECTIVES: Evaluate the role of balloon aortic valvuloplasty (BAV) in improving candidacy of patients for transcatheter aortic valve replacement (TAVR). BACKGROUND: Patients who are not candidates for TAVR may undergo BAV to improve functional and clinical status. METHODS: 117 inoperable or high-risk patients with critical aortic stenosis underwent BAV as a bridge-to-decision for TAVR. Frailty measures including gait speed, serum albumin, hand grip, activities of daily living (ADL); and NYHA functional class before and after BAV were compared. RESULTS: Mean age was 81.6 ± 8.5 years and the mean Society of Thoracic Surgeons predicted risk of mortality was 9.57 ± 5.51, with 19/117 (16.2%) patients non-ambulatory. There was no significant change in mean GS post-BAV, but all non-ambulatory patients completed GS testing at follow-up. Albumin and hand grip did not change after BAV, but there was a significant improvement in mean ADL score (4.85 ± 1.41 baseline to 5.20 ± 1.17, P = 0.021). The number of patients with Class IV congestive heart failure (CHF) was significantly lower post BAV (71/117 [60.7%] baseline versus 18/117 [15.4%], P = 0.008). 78/117 (66.7%) of patients were referred to definitive valve therapy after BAV. CONCLUSIONS: When evaluating frailty measures post BAV, we saw no significant improvement in mean GS, however, we observed a significant improvement in non-ambulatory patients and ADL scores. We also describe improved Class IV CHF symptoms. With this improved health status, the majority of patients underwent subsequent valve therapy, demonstrating that BAV may improve candidacy of patients for TAVR.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Substituição da Valva Aórtica Transcateter , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/reabilitação , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/métodos , Feminino , Força da Mão , Humanos , Masculino , Cuidados Pré-Operatórios/métodos , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
Curr Cardiol Rep ; 20(10): 82, 2018 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-30094642

RESUMO

PURPOSE OF REVIEW: To determine what influences patients and physicians to choose between transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in intermediate-surgical-risk patients with severe, symptomatic aortic stenosis. RECENT FINDINGS: Advances in transcatheter valve technology, techniques, and trials demonstrating non-inferiority compared to surgical aortic valve replacement (SAVR) have led to expanded eligibility of transcatheter aortic valve replacement (TAVR) to both intermediate-risk patients in clinical practice and low-risk patients in pivotal trials. Since lower-risk individuals tend to be younger and good operative candidates, concerns of valve durability, procedure-related morbidity, and patient survivability require careful consideration. Results from the PARTNER II intermediate risk trials and SURTAVI trials have given us insight into the benefits and potential risks of both treatment modalities. In this article, we review the brief yet remarkable history of TAVR and discuss its role in the treatment of intermediate-surgical-risk patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/métodos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 87(6): 1020-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26947260

RESUMO

With the large number of late breaking clinical trials presented at major meetings, it is often difficult to stay current with advances in interventional cardiology. Therefore, the SCAI Publications Committee summarizes and provides editorial commentary on the most important structural heart and peripheral artery disease late-breaking trials from 2015. © 2016 Wiley Periodicals, Inc.


Assuntos
Cardiologia/métodos , Ensaios Clínicos como Assunto/métodos , Cardiopatias/terapia , Doença Arterial Periférica/terapia , Sociedades Médicas , Humanos , Estados Unidos
18.
Catheter Cardiovasc Interv ; 87(7): 1314-21, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26946240

RESUMO

OBJECTIVES: To examine whether transcatheter aortic valve replacement (TAVR) is a safe and effective treatment option for aortic stenosis in patients with end-stage renal disease (ESRD). BACKGROUND: Patients with ESRD undergoing surgical aortic valve replacement have an operative mortality approaching 20% and a 10-year survival of approximately 12%. We investigated whether TAVR is a more reasonable option. METHODS: This is a multicenter, retrospective study of all patients with ESRD who underwent TAVR in 8 institutions between 12/2011 and 02/2013. Demographic characteristics, mortality, major, and minor complications were evaluated. Outcomes were stratified by operative approach. RESULTS: Forty-three patients with a mean age 76.2 ± 11.0 years and a mean STS predicted risk of mortality of 15.53 ± 8.70% underwent TAVR. Mean duration of dialysis was 45.2 ± 52.3 months (median 29.5 months). Transfemoral (TF) TAVR was performed in 31/43 (72.1%), transapical in 11/43 (25.6%), and transaortic in 1/43 (2.3%). Operative mortality was 14.0% (6/43) with TF mortality 6.5% (2/31) and 33.3% (4/12) in non-TF patients. Six-month mortality was 11/43 (25.6%: 16.1% TF, 50.0% non-TF). Complications included stroke in 2.3% (1/43) and life-threatening or major bleeding in 14.0% (6/43). Discharge to another healthcare facility was 27.0% (10/37). Readmission within 30 days of procedure for any cause was 18.9% (7/37). CONCLUSIONS: Patients with ESRD who undergo TAVR are at high risk for mortality and complications. TAVR outcomes are comparable to but not substantially better than those with SAVR. Transfemoral TAVR seems to be at least as safe and effective as the current standard SAVR in patients undergoing aortic valve replacement. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Falência Renal Crônica/complicações , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
19.
Am Heart J ; 169(4): 557-63.e6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25819863

RESUMO

BACKGROUND: Hybrid coronary revascularization (HCR) combines a surgical and percutaneous approach for treatment of multivessel coronary artery disease. METHODS: A survey was conducted among 200 cardiologists and cardiac surgeons from 100 top-ranked US hospitals. Questions were asked involving the perception, experience, and future expectations of HCR. RESULTS: Of physicians invited to the survey, 90 completed the survey (45.5%). Relative to nonresponders, responders were more often affiliated with an academic institution (80.0% vs 61.8%, P=.005), with higher patient volumes, and with the availability of a hybrid operating room (90.0% vs 67.3%, P<.001). Survey responders felt that HCR should be considered in an older and relatively healthy patient population without complex lesions. Cardiac surgeons were more favorable to use HCR in patients with chronic lung disease (42.0% vs 10.0%, P<.001) or renal failure (28.0% vs 15.0%, P=.06). Among responders with HCR experience (n=54), 94% reported good to excellent results, and the learning curve differed depending on the surgical technique used. Inappropriate patient selection (41.2%) was the most common cause for complications. Three-quarter of responders believe that the future role for HCR will expand in the next decade. Important determinants of greater HCR use in the future were collaborative associations between cardiac surgeons and cardiologists (86.7%), appropriate patient selection (67.8%), and the outcomes of ongoing clinical trials (57.8%). CONCLUSION: In this nationwide survey, cardiologists and cardiac surgeons felt that HCR is a reasonable alternative technique for coronary revascularization among suitable patients. Most felt that use of HCR would increase in the next decade.


Assuntos
Doença da Artéria Coronariana/cirurgia , Hospitais/estatística & dados numéricos , Revascularização Miocárdica/métodos , Vigilância da População/métodos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA