RESUMO
INTRODUCTION: The novel cryoballoon with 28 mm or 31 mm adjustable diameters, aims to achieve a wide antral pulmonary vein isolation (PVI). However, the distribution of antral lesions and their variations based on left atrial (LA) remodeling require further clarification. METHODS: We evaluated 22 patients (67 [59.5-74.8] years, 19 males) who underwent PVI of atrial fibrillation (AF) (13 paroxysmal AF [PAF] and 9 non-PAF) using size-adjustable cryoballoons. LA electro-anatomical mapping was performed post-PVI with three-dimensional mapping systems. We assessed the shapes of the LA and pulmonary veins (PVs) and the distribution of isolated areas (IAs), comparing the results between PAF and non-PAF patients. RESULTS: In the left PVs (LPVs), the distance between the PV orifice and IA edge (PVos-IA) was larger on the roof and posterior segments (~15 mm) but relatively smaller on the anterior segment near the PV ridge (<10 mm). For the right PVs (RPVs), it was more extensive in the posterior segment (10-15 mm). Comparing PAF and non-PAF, there were no significant differences in the PVos-IA except for the right posterior-carina segment, antrum IA (LPVs: 5.9 ± 1.6 vs. 5.8 ± 0.8 cm², p = .81; RPVs: 4.8 ± 2.3 vs. 4.8 ± 1.2 cm², p = .81), distances between the right and left IAs on the LA posterior wall (LAPW), and un-isolated LAPW area (9.0 ± 4.9 vs. 9.9 ± 2.5 cm², p = .62). No individual PVIs were observed in either group. Two patients exhibited overlapping IAs on the roof, and one patient who underwent 31 mm balloon applications for all PVs exhibited an LAPW isolation. CONCLUSION: The size-adjustable cryoballoon achieved a wide antral PVI even in non-PAF patients.
RESUMO
Recently, a novel size-adjustable cryoballoon has been introduced in clinical practice, which can be inflated to two different diameters (28 and 31 mm). The 31 mm cryoballoon is specifically designed to achieve better contact with remodeled pulmonary veins (PVs) that have wider ostia while avoiding deep cannulation, thereby potentially reducing the risk of phrenic nerve injury (PNI) associated with deep balloon cannulation. However, we encountered two cases of PNI during cryoballoon ablation using the novel system among our initial 25 consecutive case series. Herein, we present two cases that exhibited PNI during freezing of the right superior PV with a size-adjustable balloon. While larger balloons are expected to create a larger area of isolation, the safety of this novel balloon system needs to be evaluated in a large-scale clinical study.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Traumatismos dos Nervos Periféricos , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Nervo Frênico/lesões , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Traumatismos dos Nervos Periféricos/cirurgia , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
AIMS: The usefulness of coronary venous system mapping has been reported for assessing intramural and epicardial substrates in patients with scar-related ventricular tachycardia (VT). However, there has been little data on mapping from coronary arteries. We investigated the safety and utility of mapping from coronary arteries with a novel over-the-wire multielectrode catheter in scar-related VT patients. METHODS AND RESULTS: Ten consecutive scar-related VT patients with non-ischaemic cardiomyopathy who underwent mapping from a coronary artery were analysed. Six patients underwent simultaneous coronary venous mapping. High-density maps were created by combining the left ventricular endocardium and coronary vessels. Substrate maps were created during the baseline rhythm with 2438 points (IQR 2136-3490 points), including 329 (IQR 59-508 points) in coronary arteries. Abnormal bipolar electrograms were successfully recorded within coronary arteries close to the endocardial substrate in seven patients. During VT, isthmus components were recorded within the coronary vessels in three patients with no discernible isthmus components on endocardial mapping. The ablation terminated the VT from an endocardial site opposite the earliest site in the coronary arteries in five patients. CONCLUSION: The transcoronary mapping with an over-the-wire multielectrode catheter can safely record abnormal bipolar electrograms within coronary arteries. Additional mapping data from the coronary vessels have the potential to assess three-dimensional ventricular substrates and circuit structures in scar-related VT patients.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz/complicações , Cicatriz/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Ventrículos do Coração , Endocárdio , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodosRESUMO
BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.MethodsâandâResults: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.
Assuntos
Ablação por Cateter , Solução Salina , Animais , Suínos , Ventrículos do Coração/patologia , Coração , Catéteres , Ablação por Cateter/métodos , Desenho de Equipamento , Impedância ElétricaRESUMO
BACKGROUND AND AIMS: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS: Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION: TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.
Assuntos
Ablação por Cateter , Vapor , Humanos , Animais , Suínos , Irrigação Terapêutica , Desenho de Equipamento , CatéteresRESUMO
BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of ablation strategies for atrial fibrillation (AF), and noninferiority of cryoballoon (CB) over radiofrequency (RF) ablation has been previously reported. One of the risk factors of recurrence is left atrium (LA) enlargement. This study aimed to analyze the impact of LA enlargement on the selection of CB or RF ablation for AF patients. METHODS: A total of 2,224 AF patients (64.4⯱â¯10.7â¯years, 65.5% male) who underwent PVI were analyzed retrospectively. Left atrial diameter (LAD) and volume (LAV) were measured using echocardiography before the procedures. LA enlargement was defined as LAD ≥40â¯mm and LAV index (LAVI) ≥35â¯mL/m2. Patients undergoing CB and RF ablation were propensity score matched, and 376 matched pairs were evaluated. RESULTS: Cox proportional hazard analysis revealed that LAD (95% CI, 1.01-1.05), LAV (95% CI, 1.01-1.02), and LAVI (95% CI, 1.01-1.03) were independent predictors of recurrence. CB showed equivalent clinical outcomes to those of RF with shorter procedure time required for patients without LA enlargement. CB was inferior to RF in patients with LA enlargement (LAD, 74.5% vs 84.6%, Pâ¯=â¯.028; LAVI, 74.7% vs 83.4%, Pâ¯=â¯.015), and large LAVI was associated with a higher prevalence of non-PV foci (35% vs 29%, Pâ¯=â¯.008). CONCLUSIONS: CB ablation may be recommended for patients without enlarged LA based on the short procedure time and efficacy, whereas RF would be more appropriate in large LAs. LAVI may be a valuable reference to predict PVI outcomes and in selecting the ablation method.
Assuntos
Fibrilação Atrial/cirurgia , Cardiomegalia/complicações , Ablação por Cateter/métodos , Criocirurgia/métodos , Átrios do Coração/patologia , Veias Pulmonares/cirurgia , Idoso , Cardiomegalia/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Complicações Pós-Operatórias , Pontuação de Propensão , Modelos de Riscos Proporcionais , Veias Pulmonares/diagnóstico por imagem , Recidiva , Estudos Retrospectivos , Fatores de Risco , Resultado do TratamentoRESUMO
INTRODUCTION: Non-pulmonary vein (PV) triggers are a major cause of atrial tachyarrhythmia (ATA) recurrence after catheter ablation. However, the effect of the diagnosis-to-ablation time (DAT) on non-PV triggers in persistent atrial fibrillation is unknown. METHODS AND RESULTS: This observational study evaluated 502 consecutive persistent AF patients who underwent initial ablation. We compared 408 patients whose DAT was <3 years with 94 patients whose DAT was ≥3 years. Following PV and posterior wall isolation, 193 non-PV triggers, including 50 AFs, 30 atrial tachycardias (ATs), and 113 repetitive atrial premature beats, were elicited and ablated in 137 (27%) patients. Specifically, 80 non-PV AF/AT triggers were provoked in 64 (13%) patients, being identified more frequently in the DAT ≥ 3 years group than in the DAT < 3 years group (20% vs. 11%, p = .025) especially with a higher prevalence of coronary sinus/inferior left atrial triggers. During a median follow-up of 770 days, the ATA recurrence-free rate was higher in the DAT < 3 years group than the DAT ≥ 3 years group (79% vs. 53% at 2 years, p < .001). In a multivariate analysis, female sex (odds ratio: 2.70, p = .002) and a longer DAT (odds ratio: 1.13/year, p = .008) were predictors of non-PV AF/AT triggers, and a longer DAT (hazard ratio: 1.12/year, p < .001) and non-PV AT/AF triggers (hazard ratio: 1.79, p = .009) were associated with ATA recurrence. CONCLUSION: Early ablation after the first diagnosis of persistent AF may reduce emerging non-PV AF/AT triggers and ATA recurrence.
Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
INTRODUCTION: Pulmonary vein isolation (PVI) using cryoballoon is effective for patients with paroxysmal atrial fibrillation (PAF); however, few reports have evaluated the non-pulmonary vein (PV) foci after cryoballoon ablation. We aimed to evaluate the characteristics of non-PV foci and predictors of atrial fibrillation (AF) recurrence after cryoballoon ablation. METHODS AND RESULTS: This was a single-center retrospective study of 647 patients with PAF who underwent initial PVI using a second-generation cryoballoon. After PVI, all patients underwent high-dose isoproterenol infusion to assess the existence of non-PV foci. Non-PV foci were observed in 211 patients (32.6%), which were most frequently observed in the superior vena cava. Higher age (odds ratio [OR] = 1.02; 95% confidence interval [CI] = 1.00-1.04; P = .025), female sex (OR = 1.65; 95% CI = 1.13-2.41; P = .009), and lower body mass index (OR = 0.95; 95% CI = 0.89-1.00; P = .049) were significantly associated with non-PV foci. The existence of non-PV foci was an independent predictor of AF recurrence (Hazard's ratio = 1.70; 95% CI = 1.12-2.60; P = .014). When non-PV foci were mappable and successfully ablated, patients with non-PV foci showed similar outcomes with those without non-PV foci (1-year AF-free survival rates of 88.5% vs 91.5%; P = .338). Conversely, when we failed to detect and eliminate non-PV foci because they had multiple origins and were not consistently inducible (multichanging non-PV foci), the 1-year AF-free survival rate was 56.4% even after substrate modification. CONCLUSION: Non-PV foci were observed in one-third of patients with PAF after cryoballoon ablation and were associated with AF recurrence. Catheter ablation for non-PV foci was effective when they were mappable; however, multichanging non-PV foci were associated with worse prognosis.
Assuntos
Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
INTRODUCTION: Little evidence exists regarding cryoballoon ablation (CBA) of paroxysmal atrial fibrillation (PAF) in hemodialysis (HD) patients. We compared CBA and radiofrequency ablation (RFA) of PAF in HD patients, referring to CBA of PAF in non-HD patients. METHODS AND RESULTS: This historical cohort study examined 88 patients who underwent catheter ablation of PAF, including 21 HD patients with a second-generation 28-mm cryoballoon (CB-HD group), 17 HD patients with a non-force-sensing radiofrequency catheter (RF-HD group), and 50 non-HD patients with a cryoballoon (CB-non-HD group). Pulmonary vein (PV) isolation alone aside from cavotricuspid isthmus ablation was performed in 14 (67%) in the CB-HD group, 12 (71%) in the RF-HD group, and 36 (72%) in the CB-non-HD group (P = 0.95), without isoproterenol-induced non-PV triggers. Non-PV trigger ablation was added to the other patients. The Kaplan-Meier estimated 1-year freedom from atrial tachyarrhythmia recurrence without antiarrhythmic drugs after a single procedure was 76%, 59%, and, 92% in the CB-HD, RF-HD, and CB-non-HD groups, respectively (P = 0.002). The mean procedure time was shorter in the CB-HD group than in the RF-HD group (127 vs. 199 min; P < 0.001). In the second procedure, the median number of reconnected pulmonary veins was 0.5 in the CB-HD group versus 2.0 in the RF-HD group (P = 0.17). CONCLUSION: For PAF in HD patients, CBA showed a comparable single-procedure efficacy to that of RFA with a short procedure time. CBA may be a reasonable initial procedure for HD patients suffering from symptomatic PAF.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Nefropatias/terapia , Veias Pulmonares/cirurgia , Diálise Renal , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
An 82-year-old man underwent redo catheter ablation of ventricular tachycardia (VT) after anterior infarction. A ripple mapping conducting channel (RMCC) was identified within the anterior scar in the left ventricular epicardium during sinus rhythm. Along the RMCC, delayed potentials during sinus rhythm, a good pace map with a long stimulus to the QRS interval, and mid-diastolic potentials during VT were recorded, and epicardial ablation at this site eliminated the VT. These findings suggested that the RMCC in the epicardial scar served as a critical isthmus of the postinfarct VT, and ablation targeting the RMCC was effective.
Assuntos
Infarto Miocárdico de Parede Anterior/complicações , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Pericárdio/cirurgia , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Idoso de 80 Anos ou mais , Infarto Miocárdico de Parede Anterior/diagnóstico , Infarto Miocárdico de Parede Anterior/fisiopatologia , Eletrocardiografia , Frequência Cardíaca , Humanos , Masculino , Pericárdio/fisiopatologia , Valor Preditivo dos Testes , Recidiva , Reoperação , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Resultado do TratamentoRESUMO
INTRODUCTION: Several studies have revealed that second-generation cryoballoon (CB)-based pulmonary vein (PV) isolation is noninferior to radiofrequency (RF)-based PV isolation for patients with drug-refractory paroxysmal atrial fibrillation (AF). However, electrophysiological differences in repeat ablation remain unclear. METHODS AND RESULTS: This study examined electrophysiological differences during the repeat ablation between patients who first underwent RF catheter ablation and CB ablation; PV durability and non-PV AF foci were assessed for these patients. We enrolled 919 and 491 patients who underwent CB ablation (CB group) and RF catheter ablation (RF group), respectively, for paroxysmal AF between January 2013 and June 2017 at our institution. PV isolation using RF ablation involved the left atrium (LA) antrum and part of the LA posterior wall. After 2 years of follow-up, 62 and 80 patients in the CB and RF groups, respectively, underwent repeat ablation. PV reconnections were more frequent in the RF group than in the CB group (left superior PV: 46.2% and 14.5%, P < .001; left inferior PV: 35.0% and 11.2%, P = .001; right superior PV: 40.0% and 22.6%, P = .031; right inferior PV: 36.2% and 19.4%, P = .039; PVs: 39.8% and 16.9%, P < .001). LA AF foci were more frequent in the CB group than in the RF group (27.4% and 7.5%; P = .002). Other non-PV foci were prevalent in both groups. CONCLUSION: Fewer LA-PV reconnections occurred with CB ablation. However, extensive PV isolation may eliminate many LA AF foci.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de TempoRESUMO
BACKGROUND: Unipolar electrograms (uni-EGMs) are an essential part of intracardiac mapping. Although Wilson central terminal (WCT) is conventionally used as a reference for signals, avoidance of contamination by far-field and nonphysiologic signals is challenging. OBJECTIVE: The aim of the study was to explore the impact of an intracardiac indifferent reference electrode close to the recording electrodes, in lieu of WCT, on electrograms. METHODS: Sinus node activation was mapped in patients undergoing catheter ablation by a multielectrode array with a close indifferent electrode (CIE) embedded in the distal end of the catheter shaft. An equal number of points was sequentially acquired at each site with use of CIE as a reference first and subsequently with WCT. Uni-EGMs, bipolar EGMs, and the earliest activation area (defined as the area activated in the first 10 ms of the beat) were compared between CIE- and WCT-based activation maps. RESULTS: Seventeen patients (61 ± 18 years; 76% male) were studied. Uni-EGM voltages acquired with CIE were significantly larger than (n = 11) or comparable to (n = 4) those acquired with WCT. When points from the entire cohort were analyzed altogether, unipolar voltages and their maximum negative dV/dT and bipolar voltages recorded with CIE were significantly larger than those recorded with WCT (2.36 [1.42-3.79] mV vs 1.96 [1.25-3.03] mV, P < .0001; 0.40 [0.18-0.77] mV/s vs 0.35 [0.15-0.71] mV/s, P < .0001; and 1.46 [0.66-2.81] mV vs 1.33 [0.54-2.64] mV, P < .0001, respectively). The earliest activation area was significantly smaller in CIE-based activation maps than in WCT-based ones (0.3 [0.7-1.4] cm2 vs 0.6 [1.0-1.8] cm2, P = .01). CONCLUSION: CIE-based maps were associated with an approximately 20% increase in unipolar voltage and may highlight the origin of a focal activation more clearly than WCT-based ones.
Assuntos
Ablação por Cateter , Eletrodos , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Técnicas Eletrofisiológicas Cardíacas/métodos , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Desenho de Equipamento , EletrocardiografiaRESUMO
Background: We explore an optimized approach for increasing lesion size using a novel ablation catheter with a surface thermocouple and efficient irrigation in a temperature-control setting. Methods: We conducted radiofrequency applications at various power levels (35 W, 40 W, and 45 W), contact forces (CFs, 10 g/20 g), and durations (60 s/120 s/180 s) in perpendicular/parallel catheter orientations, with normal saline irrigation (NS-irrigation) and Half NS-irrigation (HNS-irrigation) in an ex-vivo model (Step 1). In addition, we performed applications (35 W/40 W/45 W for 60 s/120 s/180 s in NS-irrigation and 35 W/40 W for 60 s/120 s/180 s in HNS-irrigation) in four swine (Step 2), evaluating lesion characteristics and the occurrence of steam pops. Results: In Step 1, out of 288 lesions, we observed 47 (16.3%) steam pops, with 13 in NS-irrigation and 34 in HNS-irrigation (p = .001). Although steam pops were mostly observed with the most aggressive setting (45 W/180 s, 54%) with NS-irrigation, they happened in less aggressive settings with HNS irrigation. Lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. The optimal %impedance-drop cutoff to predict steam pops was 20% with a negative-predictive-value (NPV) = 95.1% including NS- and HNS-irrigation groups, and 22% with an NPV = 96.1% in NS-irrigation group. In Step 2, similar to the ex-vivo model, lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. Steam pops were absent with NS-irrigation (0/35) even with the largest %impedance-drop reaching 31% at 45 W/180 s. All steam pops were observed with HNS-irrigation (6/21, 29%). The optimal %impedance-drop cutoff predicting steam pops was 24% with an NPV = 96.3% including both NS- and HNS-irrigation groups. Conclusions: Rather than using HNS-irrigation, very long-duration of radiofrequency applications up to 45 W/180 s may be recommended to safely and effectively increase lesion dimensions using this catheter with NS-irrigation.
RESUMO
BACKGROUND: Catheter ablation is the curative treatment for paroxysmal supraventricular tachycardia (SVT). However, atrial tachycardia (AT) diagnosis is often challenging, especially when SVT is terminated by pacing. OBJECTIVES: This study sought to develop a novel method for AT diagnosis. METHODS: A total of 147 SVTs including 28 ATs, 87 atrioventricular nodal re-entrant tachycardias, and 32 orthodromic reciprocating tachycardias were prospectively studied. Single atrial extrastimulation was performed at the proximal coronary sinus from a coupling interval 20 milliseconds shorter than the tachycardia cycle length and gradually decreased until the His bundle (HB) was first reset and further until the SVT was terminated. The response of the SVT during the first HB resetting and the termination pattern were examined. RESULTS: In 27 of 28 ATs, tachycardia was unaffected when HB resetting whereas, in atrioventricular nodal re-entrant tachycardias or orthodromic reciprocating tachycardias (non-AT), tachycardia was simultaneously reset when HB resetting or was terminated with an atrio-Hisian block. When the coupling interval was further shortened for cases in which tachycardia persisted, all 33 SVTs with tachycardia termination with atrio-Hisian block were non-ATs, whereas 5 ATs and 7 non-ATs were terminated with Hisian-atrial block. The sensitivity, specificity, and positive and negative predictive values of the pattern of tachycardia that was unaffected when HB resetting for AT diagnosis were 96%, 100%, 100%, and 99%, respectively. Those of the pattern of tachycardia termination with atrio-Hisian block for non-AT diagnosis were 92%, 100%, 100%, and 42%, respectively. CONCLUSIONS: Single atrial extrastimulation from the proximal coronary sinus during tachycardia was useful and effective for AT diagnosis.
Assuntos
Fascículo Atrioventricular , Taquicardia Supraventricular , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Fascículo Atrioventricular/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Adulto , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Ablação por Cateter/métodos , Eletrocardiografia , Átrios do Coração/fisiopatologiaRESUMO
BACKGROUND: The innovative peak frequency mapping facilitates the quantification of electrogram sharpness. However, reference values for normal atrial tissue are currently undefined. In this study, we explored the distribution of peak frequency and omnipolar peak-to-peak voltage (V-max) in a normal heart. METHODS: Twenty-two patients with structurally normal heart were included. Either the right atrium (RA) and superior vena cava (SVC) or the left atrium (LA) and pulmonary veins (PVs) were mapped during sinus rhythm. RESULTS: In total, 13,654 points in the RA and 4143 points in the SVC from 15 patients and 4662 points in the LA and 2761 points in PVs from 7 patients were analyzed. The correlation between peak frequency and V-max was weak (R = 0.223). The median peak frequency was larger in the SVC than in the RA (441 [358-524] Hz vs. 358 [291-441] Hz, P < 0.0001) and in PVs than in the LA (346 [253-441] Hz vs. 323 [262-397] Hz, P < 0.0001). Conversely, the median V-max was smaller in the SVC than in the RA (1.96 [0.77-3.75] mV vs. 4.11 [2.10-6.83] mV, P < 0.0001) and in PVs than in the LA (1.16 [0.33-3.17] mV vs. 4.42 [2.63-6.84] mV, P < 0.0001). More than 95% of peak frequencies were > 174 Hz in the RA and > 185 Hz in the LA, and > 95% of V-maxes were > 0.52 and > 1.07 mV in the RA and LA, respectively. CONCLUSION: Given the limited correlation between peak frequency and V-max, and recognizing their potential to provide distinct information, they can be used complementarily. Employing these parameters to extract varied insights can provide comprehensive understandings of tissue characteristics.
RESUMO
BACKGROUND: The QDOT-MICRO catheter enables very high power and short duration (vHPSD) ablation. However, low first-pass isolation rates have been reported, possibly because of shallow lesion formation, necessitating deeper lesions to improve treatment outcomes. OBJECTIVE: This study aimed to confirm the safety and efficacy of double radiofrequency applications of vHPSD ablation in an in vivo beating swine heart model. METHODS: Eighteen swine were anesthetized and underwent vHPSD ablation using the QDOT-MICRO catheter at 90 W for 4 seconds, targeting a contact force of 10 g. Radiofrequency applications were performed as single application (SA) and double applications (DAs) with 4- to 8-second rest intervals. Lesion surface area and volume were measured postablation. RESULTS: A total of 337 atrial lesions and 74 ventricular lesions were created. Both 4- to 6-second DA and 7- to 8-second DA produced significantly larger and deeper lesions than did SA, with atrial surface lengths averaging 9.0 mm for 4- to 6-second DA, 9.2 mm for 7- to 8-second DA, and 8.0 mm for SA. Transmurality was observed at 100% for 4- to 6-second and 7- to 8-second DAs, while it was 94% for SA (P = .002). Ventricular lesion metrics followed similar trends. Except for 1 event of tiny char formation during 4-second DA in the ventricle, neither steam pops nor char formation was observed in either the atrium or the ventricle. CONCLUSION: In an in vivo swine heart model, DA with 4- to 6-second and 7- to 8-second intervals create deeper and wider lesions than does SA, suggesting its potential for clinical application in areas with thicker myocardial walls. However, DA with very short intervals may still pose a risk of excessive tissue heating.
RESUMO
Introduction: The safety of hyperbaric oxygen treatment (HBO2) in patients with cardiovascular implanted electronic devices (CIED) remains unclear. Methods: We conducted a retrospective analysis of seven CIED patients (median age 79 [73-83] years, five males [71.4%]), including five with pacemakers and two with implantable cardioverter defibrillators (ICD), who underwent HBO2 between June 2013 and April 2023. During the initial session, electrocardiogram monitoring was conducted, and CIED checks were performed before and after the treatment. In addition, the medical records were scrutinized to identify any abnormal CIED operations. Results: All seven CIED patients underwent HBO2 within the safety pressure range specified by the CIED manufacturers or general pressure test by the International Organization for Standardization (2.5 [2.5-2.5] atmosphere absolute × 18 [5-20] sessions). When comparing the CIED parameters before and after HBO2, no significant changes were observed in the waveform amplitudes, pacing thresholds, lead impedance of the atrial and ventricular leads, or battery levels. All seven patients, including two with the rate response function activated, exhibited no significant changes in the pacing rate or pacing failure. Two ICD patients did not deactivate the therapy, including the defibrillation; however, they did not experience any arrhythmia or inappropriate ICD therapy during the HBO2. Conclusion: CIED patients who underwent HBO2 within the safety pressure range exhibited no significant changes in the parameters immediately after the HBO2 and had no observable abnormal CIED operations during the treatment. The safety of defibrillation by an ICD during HBO2 should be clarified.
RESUMO
Background: Lesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature-guided very high-power short-duration (vHPSD) ablation, which was therefore the purpose of this study. Methods: Radiofrequency applications (90 W/4 s, temperature-control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT-MICRO™ catheter. Ten lesions for each combination of settings were created, and lesion metrics and steam-pops were compared. Results: A total of 320 lesions were analyzed. Lesion depth, surface area, and volume were smallest for CF of 5 g than for 15, 25, and 35 g (depth: 2.7 mm vs. 2.9 mm, 3.0 mm, 3.15 mm, p < .01; surface area: 38.4 mm2 vs. 41.8 mm2, 43.3 mm2, 41.5 mm2, p < .05; volume: 98.2 mm3 vs. 133.3 mm3, 129.4 mm3, 126.8 mm3, p < .01 for all pairs of groups compared to CF = 5 g). However, no significant differences were observed between CFs of 15-35 g. Average power was highest for CF of 5 g, followed by 15, 25, and 35 g (83.2 W vs. 82.1 W vs. 77.1 W vs. 66.1 W, p < .01 for all pairs), reflecting the higher incidence of temperature-guided power titration with greater CFs (5 g:8.8% vs. 15 g:52.5% vs. 25 g:77.5% vs. 35 g:91.2%, p < .01 for all pairs except for 25 g vs. 35 g). The incidence of steam-pops did not significantly differ between four groups (5 g:3.8% vs. 15 g:10% vs. 25 g:6.2% vs. 35 g:2.5%, not significant for all pairs). Conclusions: For vHPSD ablation, lesion size does not become large once the CF reaches 15 g, and the risk of steam-pops may be mitigated through power titration even in high CFs.
RESUMO
BACKGROUND: Atrial fibrillation (AF) is a prevalent multifactorial arrhythmia associated with specific single-nucleotide polymorphisms (SNPs). Pulmonary vein (PV) isolation is an established treatment for AF; however, recurrence risk remains caused by AF triggers beyond the PVs. Understanding the embryological origins of these triggers could improve treatment outcomes. OBJECTIVES: This study aimed to investigate the association between embryologically categorized AF triggers, clinical and genetic backgrounds, and postablation prognosis. METHODS: In cohort 1, comprising 3,067 patients with AF undergoing PV isolation, the clinical characteristics and outcomes were analyzed. Among them, 815 patients underwent genetic analysis using AF-associated SNPs (cohort 2). Patients were delineated based on the developmental origin of the AF triggers: common PV, sinus venosus (SV), and primitive atrium (PA). RESULTS: SV-origin extra-PV AF triggers occurred in 20.3% (n = 622) of patients, whereas PA-origin triggers occurred in 11.9% (n = 365) of patients in cohort 1. Multivariate analysis of cohort 2 revealed that female sex, lower body mass index, absence of hypertension, rs2634073 near PITX2, and rs6584555 in NEURL1 were associated with SV-AF, whereas nonparoxysmal AF and rs2634073 near PITX2 were predictors of PA-AF. The PA group had a significantly higher arrhythmia recurrence rate after repeated procedures than the common PV (HR: 1.75; 95% CI: 1.34-2.29; P < 0.001) and SV-AF (HR: 1.31; 95% CI: 1.19-1.45; P < 0.001) groups with more de novo AF triggers. However, the incidence of adverse events did not differ significantly among the 3 groups. CONCLUSIONS: SV-derived AF triggers may have hereditary factors with a favorable postablation prognosis, whereas PA-derived triggers are linked to AF persistence and poor ablation response. Variants near PITX2 may play a pivotal role in extra-PV triggers.
RESUMO
PURPOSE: Radiofrequency (RF) ablation with half-normal saline (HNS) irrigation is reported to potentially enlarge local lesion compared to normal saline (NS) in power-controlled ablation (PC-Abl). However, the effect of HNS-irrigation in temperature-flow-controlled ablation (TFC-Abl) on lesion characteristics is unknown. We compared this between TFC-Abl with QDOT-Micro™ catheter and PC-Abl with Thermocool SmartTouch SF™ catheter (STSF). METHODS: RF-application with NS (n = 480) and HNS (n = 480) irrigation were performed on swine myocardium placed in a circulating saline bath. Lesion characteristics without steam-pops under various conditions (target AI, 400/550; ablation power, 30/50 W; contact force, 10/20/30 g; catheter orientation, perpendicular/parallel) were assessed and compared between two irrigants. RESULTS: After matching, 343 lesions without steam-pops in each group were evaluated. In PC-Abl, lesion size did not differ between two groups (NS, 188 ± 97 vs. HNS, 200 ± 95 mm3, p = 0.28 in volume; 33.9 ± 7.3 vs. 34.8 ± 9.5 mm2, p = 0.34 in surface area; and 4.0 ± 1.0 vs. 4.0 ± 1.0 mm, p = 0.81 in depth), but steam-pops were more frequently observed with HNS-irrigation (23.8% vs. 37.9%, p = 0.001). Contrary, in TFC-Abl, HNS-irrigation produced significantly larger (214 ± 106 vs. 243 ± 128 mm3, p = 0.017) and deeper (4.0 ± 1.0 vs. 4.3 ± 1.1 mm, p = 0.002) lesions without increasing the risk of steam-pops (15.0% vs 15.0%, p = 0.99). Automatic temperature-guided titration was more frequently observed in HNS-irrigation (54.8% vs. 78.5%, p < 0.001). CONCLUSIONS: TFC-Abl with QDOT-Micro™ catheter utilizing HNS-irrigation might increase volume and depth of local lesion without increasing the risk of stem-pops compared to NS-irrigation. Power-controlled ablation with HNS-irrigation showed similar focal lesion with higher incidence of steam-pops (SPs) compared to normal saline (NS) irrigation. Contrary, temperature-flow-controlled ablation with HNS-irrigation provided larger and deeper lesion than NS-irrigation with similar incidence of SPs. ns, p > 0.05; *, 0.01 < p ≤ 0.05; **, 0.005 < p ≤ 0.01. HNS, half-normal saline; NS, normal saline.