Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ J ; 88(4): 501-509, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37813600

RESUMO

BACKGROUND: Fractional flow reserve-computed tomography (FFRCT) has not been validated in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) for coronary artery disease due to theoretical difficulties in using nitroglycerin for such patients.Methods and Results: In this single-center study, we prospectively enrolled 21 patients (34 vessels) and performed pre-TAVR FFRCTwithout nitroglycerin, pre-TAVR invasive instantaneous wave-free ratio (iFR) measurements, and post-TAVR FFR measurements using a pressure wire. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of pre-TAVR FFRCT≤0.80 to predict post-TAVR invasive FFR ≤0.80 were 82%, 83%, 82%, 71%, and 90%, respectively. A receiver operating characteristic analysis demonstrated an optimal cutoff of 0.78 for pre-TAVR FFRCTto indicate post-TAVR FFR ≤0.80, with an area under the curve (AUC) of 0.84, and the counterpart cutoff of pre-TAVR iFR was 0.89 with an AUC of 0.86. CONCLUSIONS: FFRCTwithout nitroglycerin could be a useful non-invasive imaging modality for assessing the severity of coronary artery lesions in patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Nitroglicerina , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Doença da Artéria Coronariana/cirurgia , Tomografia Computadorizada por Raios X , Valor Preditivo dos Testes , Vasos Coronários , Isquemia/cirurgia , Angiografia Coronária/métodos , Índice de Gravidade de Doença
2.
Circ J ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39019582

RESUMO

The 88thAnnual Scientific Meeting of the Japanese Circulation Society (JCS2024) was held from Friday, March 8thto Sunday, March 10thin Kobe, Japan. The main theme of this 3-day meeting was "The Future of Cardiology: Challenges in Overcoming Cardiovascular Disease". As COVID-19 has been finally conquered, with revision of its categorization under the Infectious Disease Control Law and relaxation of infection prevention measures, it was once again possible to have face-to-face presentations and lively discussion. JCS2024 was a major success, with 19,209 participants and attendees, thanks to the greatly appreciated cooperation and support from all affiliates.

3.
Heart Vessels ; 39(8): 735-745, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38526753

RESUMO

BACKGROUND: Murray law-based quantitative flow ratio (µQFR) is a novel computational method that enables accurate estimation of fractional flow reserve (FFR) using a single angiographic projection. However, its diagnostic value in patients with severe aortic stenosis (AS) remains unclear. METHOD: We included 25 consecutive patients who underwent transcatheter aortic valve replacement (TAVR) for severe AS with intermediate or greater (30-90%) coronary artery disease (CAD). Pre- and post-TAVR µQFR, QFR, instantaneous flow reserve (iFR), and post-TAVR invasive FFR values were measured. We evaluated the diagnostic performance of pre-TAVR µQFR, QFR, and iFR using post-TAVR FFR ≤ 0.80 as a reference standard of ischemia. RESULT: Pre-TAVR µQFR was significantly correlated with post-TAVR FFR (r = 0.73, p < 0.0001). The area under the curve of pre-TAVR µQFR on post-TAVR FFR ≤ 0.8 was 0.91 (95% confidence interval [CI] 0.77-0.98), comparable to that of pre-TAVR iFR (0.86 [95% CI 0.71-0.98], p = 0.97). The accuracy, sensitivity, specificity, and positive and negative predictive values of pre-TAVR µQFR on post-TAVR FFR ≤ 0.8 were 84.2% (95% CI 68.7-93.4), 61.6% (95% CI 31.6-86.1), 96.0% (95% CI 79.6-99.9), 88.9% (95% CI 52.9-98.3), and 82.8% (95% CI 70.6-90.6), respectively. For pre-TAVR iFR, these values were 76.5% (95% CI 58.8-89.3), 90.9% (95% CI 58.7-99.8), 69.6% (95% CI 47.1-86.8), 58.8% (95% CI 42.8-73.1), and 94.1% (95% CI 70.8-99.1), respectively. CONCLUSION: µQFR could be useful for the physiological evaluation of patients with severe AS with concomitant CAD.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Masculino , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia
4.
Heart Vessels ; 38(5): 634-644, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36617625

RESUMO

The relationship between high wall shear stress (WSS) and plaque rupture (PR) in longitudinal and circumferential locations remains uncertain. Overall, 100 acute coronary syndrome patients whose culprit lesions had PR, documented by optical coherence tomography (OCT), were enrolled. Lesion-specific three-dimensional coronary artery models were created using OCT data. WSS was computed with computational fluid dynamics analysis. PR was classified into upstream-PR, minimum lumen area-PR, and downstream-PR according to the PR's longitudinal location, and into central-PR and lateral-PR according to the disrupted fibrous cap circumferential location. In the longitudinal 3-mm segmental analysis, multivariate analysis demonstrated that higher WSS in the upstream segment was independently associated with upstream-PR, and thinner fibrous cap was independently associated with downstream-PR. In the PR cross-sections, the PR region had a significantly higher average WSS than non-PR region. In the cross-sectional analysis, the in-lesion peak WSS was frequently observed in the lateral (66.7%) and central regions (70%) in lateral-PR and central-PR, respectively. Multivariate analysis demonstrated that the presence of in-lesion peak WSS at the lateral region, thinner broken fibrous cap, and larger lumen area were independently associated with lateral-PR, while the presence of in-lesion peak WSS at the central region and thicker broken fibrous cap were independently associated with central-PR. In conclusion, OCT-based WSS simulation revealed that high WSS might be related to the longitudinal and circumferential locations of PR.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/patologia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/etiologia , Estudos Transversais , Placa Aterosclerótica/complicações , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Fibrose , Tomografia de Coerência Óptica/métodos , Angiografia Coronária/métodos
5.
Heart Vessels ; 37(11): 1937-1946, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35641828

RESUMO

Percutaneous transluminal septal myocardial ablation (PTSMA) is a well-established interventional therapy for drug-refractory hypertrophic obstructive cardiomyopathy (HOCM) as an alternative to surgical myectomy. Although guidelines recommend that PTSMA should be performed in institutions with extensive experience, it is not centralized to such high-volume centers in real-world clinical practice. Thus, this study aimed to assess the feasibility of PTSMA in non-high-volume centers. We retrospectively examined patients with HOCM who underwent PTSMA between August 2012 and May 2020 at four institutions that experienced fewer than 20 cases of PTSMA procedures. The primary clinical endpoint was a composite of safety (all-cause death, electrical defibrillation for ventricular tachycardia or fibrillation, cardiac tamponade, permanent pacemaker implantation, and repeated interventions) and efficacy endpoints (repeated interventions [PTSMA or surgical myectomy]). Fifty-eight consecutive patients were enrolled. During the 30-day follow-up, no major clinical adverse events were noted except three patients (5.2%) requiring permanent pacemaker implantation for complete atrioventricular block. The percentage of patients with New York Heart Association functional class 1 or 2 significantly increased from 8.6 to 100% (p < 0.001). In the Cox proportional hazard model, left ventricular outflow tract pressure gradient at rest ≥ 30 mmHg (hazard ratio [HR] 6.56; 95% confidence interval [CI] 1.44-29.90; p = 0.015) and mitral regurgitation grade ≥ 3 (HR 10.75; 95% CI 1.81-63.79; p = 0.009) at the 30-day follow-up were associated with a composite of major clinical adverse events. The current study demonstrated that 58 patients who underwent PTSMA in non-high-volume centers had favorable 30-day clinical outcomes, with a primary composite endpoint rate of 5.2%. A prospective study with a larger sample size and longer follow-up is warranted to verify the safety and efficacy of PTSMA in non-high-volume centers.


Assuntos
Cardiomiopatia Hipertrófica , Ablação por Cateter , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ecocardiografia , Seguimentos , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Humanos , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
6.
Heart Vessels ; 37(1): 1-11, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34338851

RESUMO

The initial process of atherosclerotic development has not been systematically evaluated. This study aimed to observe atherosclerotic progression from normal vessel wall (NVW) to atherosclerotic plaque and examine local factors associated with such progression using > 5-year long-term follow-up data obtained by serial optical coherence tomography (OCT). A total of 49 patients who underwent serial OCT for lesions with NVW over 5 years (average: 6.9 years) were enrolled. NVW was defined as a vessel wall with an OCT-detectable three-layer structure and intimal thickness ≤ 300 µm. Baseline and follow-up OCT images were matched, and OCT cross sections with NVW > 30° were enrolled. Cross sections were diagnosed as "progression" when the NVW in these cross sections was reduced by > 30° at > 5-year follow-up. Atherogenic progression from NVW to atherosclerotic plaque was observed in 40.8% of enrolled cross sections. The incidence of microchannels in an adjacent atherosclerotic plaque within the same cross section (6.7 vs. 3.3%; p = 0.046) and eccentric distribution of atherosclerotic plaque (25.0 vs. 12.6%; p < 0.001) at baseline was significantly higher in cross sections with progression than in those without. Cross sections with progression exhibited significantly higher NVW intimal thickness at baseline than cross sections without progression (200.1 ± 53.7 vs. 180.2 ± 59.6 µm; p < 0.001). Multivariate analysis revealed that the presence of microchannels in an adjacent atherosclerotic plaque, eccentric distribution of atherosclerotic plaque, and greater NVW intimal thickness at baseline were independently associated with progression at follow-up. The presence of microchannels in an adjacent atherosclerotic plaque, eccentric distribution of atherosclerotic plaque, and greater NVW intimal thickness were potentially associated with initial atherosclerotic development from NVW to atherosclerotic plaque.


Assuntos
Placa Aterosclerótica , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Seguimentos , Humanos , Tomografia de Coerência Óptica
7.
Echocardiography ; 39(2): 248-259, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35038184

RESUMO

BACKGROUND: The sigmoid septum has been generally evaluated subjectively and qualitatively, without detailed examination of its diversity, impact on the morphology of the left ventricular outflow tract (LVOT), and anatomical background. METHODS: We enrolled 100 patients without any background cardiac diseases (67.5 ± 12.8 years old; 43% women) who underwent cardiac computed tomography. Basal septal morphology was evaluated using antero-superior and medial bulging angles (bidirectional angulation of the basal septum relative to the LVOT). The eccentricity index of the LVOT, area narrowing ratio (LVOT/virtual basal ring area), aortic-to-left ventricular axial angle (angulation of the aortic root relative to the left ventricle), and wedged height (non-coronary aortic sinus to inferior epicardium distance) were also quantified. RESULTS: The antero-superior bulging, medial bulging, aortic-to-left ventricular axial angles, LVOT eccentricity index, area narrowing ratio, and wedged height were 76° ± 17°, 166° ± 27°, 127° ± 9°, 1.8 ± 0.5, 1.0 ± 0.2, and 41.2 ± 9.1 mm, respectively. Both bulging angles were correlated with each other and contributed to the narrowing and deformation of the LVOT. Angulated aortic root was not correlated with either bidirectional septal bulge or LVOT narrowing. Clockwise rotation of the aortic root rotation was an independent predictor of prominent antero-superior septal bulge. Deeper aortic wedging was a common independent predictor of bidirectional septal bulge. CONCLUSIONS: The extent of septal bulge varies in normal hearts. Along with deep aortic wedging, the bidirectional bulge of the basal septum deforms and narrows the LVOT without affecting the virtual basal ring morphology.


Assuntos
Coração , Obstrução do Fluxo Ventricular Externo , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia
8.
Circ J ; 85(7): 1059-1067, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-33408304

RESUMO

BACKGROUND: A thorough understanding of the anatomy of the aortic valve is necessary for aortic valve-sparing surgery. Normal valvar dimensions and their relationships in the living heart, however, have yet to be fully investigated in a 3-dimensional fashion.Methods and Results:In total, 123 consecutive patients (66±12 years, Men 63%) who underwent coronary computed tomographic angiography were enrolled. Mid-diastolic morphology of the aortic roots, including height of the interleaflet triangles, geometric height, free margin length of each leaflet, effective height, and coaptation length were measured using multiplanar reconstruction images. Average height of the interleaflet triangle, geometric height, free margin length, effective height, and the coaptation length were 17.3±1.8, 14.7±1.3, 32.6±3.6, 8.6±1.4, and 3.2±0.8 mm, respectively. The right coronary aortic leaflet displayed the longest free margin length and shortest geometric height. Geometric height, free margin length, and effective height showed positive correlations with aortic root dimensions. Coaptation length, however, remained constant regardless of aortic root dimensions. CONCLUSIONS: Diversities, as well as characteristic relationships among each value involving the aortic root, were identified using living-heart datasets. The aortic leaflets demonstrated compensatory elongation along with aortic root dilatation to maintain constant coaptation length. These measurements will serve as the standard value for revealing the underlying mechanism of aortic regurgitation to plan optimal aortic valve-sparing surgery.


Assuntos
Doenças da Aorta , Insuficiência da Valva Aórtica , Adulto , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Humanos , Masculino
9.
Circ J ; 85(6): 808-816, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-33431718

RESUMO

BACKGROUND: The impact of antiplatelet drug effects on mid-term local arterial responses following percutaneous coronary intervention (PCI) remains uncertain. We evaluated the impact of the platelet reactivity of prasugrel on mid-term vascular healing between acute coronary syndrome (ACS) and stable coronary artery disease (CAD).Methods and Results:We conducted a prospective, 12-center study in 125 patients with ACS and 126 patients with stable CAD who underwent PCI with an everolimus-eluting stent (EES) and received dual antiplatelet therapy (DAPT) with prasugrel and aspirin. Serial optical coherence tomography (OCT) was performed immediately after PCI and at the 9-month follow-up to assess the association of P2Y12reaction units (PRU) with the frequency of malapposed or uncovered struts and intrastent thrombi (IST). The incidence of abnormal mid-term OCT findings did not different between the ACS and CAD arms, regardless of clinical presentation, except that uncovered struts were more frequent in the ACS than CAD arm. PRU at PCI was significantly associated with the frequency of IST at follow-up, but not with uncovered and malapposed struts. PRU at PCI was the only independent predictor of IST detected at follow-up (odds ratio 1.009). CONCLUSIONS: In patients undergoing EES implantation and receiving prasugrel, achieving an adequate antiplatelet effect at the time of stent implantation may regulate thrombus formation throughout the follow-up period.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Trombose , Síndrome Coronariana Aguda/tratamento farmacológico , Doença da Artéria Coronariana/tratamento farmacológico , Stents Farmacológicos , Everolimo , Fibrinolíticos , Humanos , Cloridrato de Prasugrel/uso terapêutico , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento
10.
Heart Vessels ; 36(9): 1265-1274, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33830314

RESUMO

Whether predicting the rotational atherectomy (RA) effect based on the position of optical frequency domain imaging (OFDI) is accurate remains uncertain. The aim of this study was to evaluate the predictive accuracy of OFDI in identifying RA location and area. Twenty-five patients who underwent RA with OFDI were included. On pre-RA OFDI images, a circle with the dimension of a Rota burr was drawn at the center of the OFDI catheter. The area where the circle overlapped with the vessel wall was defined as the predicted ablation area (P-area), and the actual ablated area (A-area) was measured. The predictive accuracy of OFDI was evaluated as follows: overlapped ablation area (O-area: overlapping P- and A-areas) divided by P-area = %Correct-area, and A-area - O-area divided by A-area = %Error-area. Cross-sections were separated into four categories based on the median values of %Correct- and %Error-area. Among 334 cross-sections, RA effects were confirmed in the predicted location in 87% of them. The median %Correct- and %Error-areas were 43.1% and 64.2%, respectively. Floppy wire, narrow lumen area, OFDI catheter close to the intima, and large arc of calcium were independently associated with good prediction (high %Correct-/low %Error-areas). Non-left anterior descending lesions, OFDI catheter far from the wire, and OFDI catheter and wire far from the intima were associated with irrelevant ablation (low %Correct-/ high %Error-areas). The accuracy of the OFDI-based predictions for RA effects was acceptable with regard to location, but not high with regard to area. Wire types, target vessels, and OFDI catheter and wire positions are important determinants for accurately predicting RA effect using pre-procedural OFDI.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Procedimentos Cirúrgicos de Citorredução , Humanos , Tomografia de Coerência Óptica , Resultado do Tratamento
11.
Heart Vessels ; 36(6): 818-826, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33481085

RESUMO

Optical frequency domain imaging (OFDI) is a high-resolution intracoronary imaging modality with fast automated longitudinal pullback. We aimed to evaluate the ability of performing OFDI from the superficial femoral artery (SFA) to the below-knee (BK) artery. This clinical trial was a multi-center, single-arm, open-label study. The primary endpoint was to obtain a clear image of the intra-vascular lumen from the SFA to the BK artery, specifically > 270° visualization of the blood vessel lumen with > 16/21 cross sections. The proportion of the clear image (≥ 85%) was regarded as confirmatory of the ability of OFDI to visualize the vessel lumen. Overall, 20 patients were enrolled. The proportion of the primary endpoint was 90% (18/20), and the pre-specified criterion was successfully attained. The proportion of the clear image assessed by the operator was 100% (20/20), and an additional statistical analysis for the proportion of the visualization, > 270°, of the blood vessel lumen revealed a significantly higher cut-off value than that for the pre-specified criterion, 85% (p = 0.0315). There were three adverse events not related to OFDI. OFDI achieved acceptable visualization of the vessel lumen without any adverse event related to it. After regulatory approval based on the present study, OFDI will be available as a new option of endovascular imaging for peripheral artery diseases in daily practiceTrial registration: This study was registered in the Japanese Registry of Clinical Trials (jRCT 2052190025, https://jrct.niph.go.jp/latest-detail/jRCT2052190025 ).


Assuntos
Artéria Femoral/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Doença Arterial Periférica/diagnóstico , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Feminino , Humanos , Masculino , Método Simples-Cego
12.
Heart Vessels ; 36(8): 1234-1245, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33615425

RESUMO

Assessment of frailty is important for risk stratification among the elderly with severe aortic stenosis (AS) when considering interventions such as surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). However, evidence of the impact of preoperative frailty on short-term postoperative outcomes or functional recovery is limited. This retrospective study included 234 consecutive patients with severe AS who underwent SAVR or TAVR at Kobe University Hospital between Dec 2013 and Dec 2019. Primary outcomes were postoperative complications, postoperative 6-min walking distance (6MWD), and home discharge rates. The mean age was 82 ± 6.6 years. There were 169 (SAVR: 80, TAVR: 89) and 65 (SAVR: 20, TAVR: 45) patients in the non-frail and frail groups, respectively (p = 0.02). The postoperative complication rates in the frail group were significantly higher than those in the non-frail group [30.8% (SAVR: 35.0%, TAVR: 28.9%) vs. 10.7% (SAVR: 15.0%, TAVR: 6.7%), p < 0.001]. The home discharge rate in the non-frail group was significantly higher than that in the frail group [85.2% (SAVR: 81.2%, TAVR: 88.8%) vs. 49.2% (SAVR: 55.0%, TAVR: 46.7%), p < 0.001]. The postoperative 6MWD in the non-frail group was significantly longer than that in the frail group [299.3 ± 87.8 m (SAVR: 321.9 ± 90.8 m, TAVR: 281.1 ± 81.3 m) vs. 141.9 ± 92.4 m (SAVR: 167.8 ± 92.5 m, TAVR: 131.6 ± 91.3 m), p < 0.001]. The TAVR group did not show a decrease in the 6MWD after intervention, regardless of frailty. We report for the first time that preoperative frailty was strongly associated with postoperative complications, 6MWD, and home discharge rates following both SAVR and TAVR. Preoperative frailty assessment may provide useful indications for planning better individualized therapeutic interventions and supporting comprehensive intensive care before and after interventions.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Tolerância ao Exercício , Fragilidade/complicações , Fragilidade/diagnóstico , Humanos , Alta do Paciente , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos
13.
Clin Anat ; 34(3): 333-341, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32249462

RESUMO

INTRODUCTION: Two-dimensional measurements are self-evidently limited when seeking accurately to represent the three-dimensional complexity of the aortic root. Volumetric measurement, therefore, seems an ideal alternative for a more accurate assessment. MATERIALS AND METHODS: We retrospectively analyzed 123 individuals undergoing cardiac computed tomography. We measured the dimensions of the sinuses of Valsalva using routine multiplanar short axis imaging. Three conventional two-dimensional methods were applied to measure the dimensions of the sinuses. These involved bisecting center of sinus-to-center of interleaflet triangle measures, along with center of sinus-to-center of sinus, and largest sinus-to-sinus measurements. We then quantified the volumes of the root using the volume-rendering method. RESULTS: The mean dimensions of the sinuses were significantly greater when measured using the largest sinus-to-sinus method as opposed to center of sinus-to-center of interleaflet triangle and center of sinus-to-center of sinus methods (33.6 ± 3.6 mm vs. 31.1 ± 3.1 mm and 30.9 ± 3.3 mm, p < .0001). The mean root volume of 13.6 ± 4.2 ml showed the strongest correlation with the mean dimensions of the sinuses of Valsalva measured using the bisecting method (R2 = .8401, p < .0001). CONCLUSIONS: By using two- and three-dimensional measurements, we have provided average data for the structurally normal aortic root. The differences and correlations encountered should be noted when evaluating and following changes in the diseased root.


Assuntos
Aorta Torácica/anatomia & histologia , Aorta Torácica/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
J Cardiovasc Electrophysiol ; 31(4): 915-920, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32090387

RESUMO

BACKGROUND: The left ventricular apex commonly has a paper-thin structure. However, available data about its structure are limited to variable samples, methodologies, and results. OBJECTIVE: To investigate the structural anatomy of the left ventricular apex using living heart datasets with the latest computed tomography scanner. METHODS: One hundred thirty-one consecutive patients (median age, 73 years; 58% men) who underwent cardiac computed tomography were retrospectively analyzed. Patients with severe aortic stenosis were analyzed separately. Thickness and diameters of the thinnest part of the left ventricular apex during mid-diastole were measured using orthogonal multiplanar reconstruction images. The area of thinning was estimated using the formula for the ellipse. RESULTS: In 88 patients without severe aortic stenosis, the median thickness of the thinnest area of the left ventricular apex was only 0.9 mm. Among them, 74%, 99%, and 100% of cases displayed a left ventricular apex thinner than 1.0, 3.0, and 5.0 mm, respectively. The median area of the thinnest region was 5.6 mm2 . In 43 patients with severe aortic stenosis, the median thickness of the thinnest area of the left ventricular apex was 1.2 mm. Among them, 51%, 93%, and 100% of cases displayed a left ventricular apex thinner than 1.0, 3.0, and 5.0 mm, respectively. The median area of the thinnest region was 3.9 mm2 . CONCLUSIONS: Localized thinning of the left ventricular apex is unexceptional, regardless of aortic stenosis with concentric left ventricular hypertrophy, thus highlighting the need for a reappreciation of this feature to avoid inadvertent catastrophic complications.


Assuntos
Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Cardiopatias/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Índice de Gravidade de Doença , Função Ventricular Esquerda , Remodelação Ventricular , Adulto Jovem
15.
Circ J ; 84(10): 1826-1836, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32759543

RESUMO

BACKGROUND: In-stent neoatherosclerosis (NA) is a risk for future cardiovascular events through atherosclerotic progression in non-stented lesions. Using optical coherence tomography, this study assessed the efficacy of intensive therapy with 10 mg/day rosuvastatin plus 1,800 mg/day eicosapentaenoic acid (EPA) vs. standard 2.5 mg/day rosuvastatin therapy on native coronary plaques in patients with NA.Methods and Results:This was a subgroup analysis of the randomized LINK-IT trial, which was designed to compare changes in the lipid index in NA between intensive and standard therapy for 12 months. In all, 42 patients with native coronary plaques and NA were assessed. Compared with standard therapy, intensive therapy resulted in greater decreases in serum low-density lipoprotein cholesterol concentrations and greater increases in serum 18-hydroxyeicosapentaenoic acid concentrations, with significantly greater decreases in the lipid index and macrophage grade in both NA (-24 vs. 217 [P<0.001] and -15 vs. 24 [P<0.001], respectively) and native coronary plaques (-112 vs. 29 [P<0.001] and -17 vs. 1 [P<0.001], respectively) following intensive therapy. Although there was a greater increase in the macrophage grade in NA than in native coronary plaques in the standard therapy group, in the intensive therapy group there were comparable reductions in macrophage grade between NA and native coronary plaques. CONCLUSIONS: Compared with standard therapy, intensive therapy prevented atherosclerotic progression more effectively in native coronary plaques in patients with NA.


Assuntos
Anticolesterolemiantes/administração & dosagem , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/etiologia , Progressão da Doença , Stents Farmacológicos/efeitos adversos , Ácido Eicosapentaenoico/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica/tratamento farmacológico , Rosuvastatina Cálcica/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Quimioterapia Combinada/métodos , Feminino , Seguimentos , Humanos , Masculino , Neointima/diagnóstico por imagem , Neointima/etiologia , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
16.
Clin Anat ; 33(8): 1240-1248, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32012343

RESUMO

BACKGROUND: Configurational changes in the proximal aorta are relevant to the procedural difficulty of transcatheter aortic valve implantation (TAVI). Among several morphological changes involving the ascending aorta, elongation is characteristics of elderly patients with aortic stenosis and can compromise the success and safety of TAVI. However, the effect of ascending aortic elongation on the overall morphology of the proximal aorta has not been established. AIMS: Our primary purpose was to investigate the effect of ascending aortic elongation on structural changes in the proximal aorta in TAVI candidates. MATERIALS & METHODS: In total, 121 consecutive patients with severe aortic stenosis (mean age, 84.5 ± 5.3 years; 69% women) who had undergone preprocedural computed tomography before TAVI were enrolled. We examined the structural anatomy of the proximal aorta in detail, focusing on its elongation, dilatation, tilting, rotation, and wedging. RESULTS: The mean length of the ascending aorta was 68.0 ± 9.2 mm, and the length was significantly correlated with dilatation (R = .278, p = .002), rightward tilting (R = .437, p < .001), clockwise rotation (R = .228, p = .018), and deep wedging (R = -.366, p < .001) of the proximal aorta. Elongation of the ascending aorta was correlated with dilatation, rightward tilting, clockwise rotation, and deep wedging of the proximal aorta in an elderly population with severe aortic stenosis. DISCUSSION: Appreciation of the clinical anatomy around the proximal aorta is required for clinicians involved in TAVI to estimate the procedural difficulty. CONCLUSION: Elongation of the ascending aorta was associated with dilatation, rightward tilting, clockwise rotation, and deep wedging of the proximal aorta.


Assuntos
Aorta/patologia , Estenose da Valva Aórtica/patologia , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Técnicas de Imagem Cardíaca , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
17.
Heart Vessels ; 34(6): 936-947, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30599059

RESUMO

The impact of dual antiplatelet therapy (DAPT) with adjusted-dose (3.75 mg/day) prasugrel for Japanese patients has not been fully investigated in terms of local arterial healing following the elective percutaneous coronary intervention (PCI). The ROUTE-01 elective study was a prospective, 12-center and single-arm registry that enrolled 123 patients who underwent elective PCI with everolimus-eluting stents (EESs) under DAPT with a combination of adjusted-dose prasugrel and aspirin. Serial optical coherence tomography (OCT) was performed at the index PCI and 9-month follow-up to assess the relationship between in-stent thorombus (IST) and residual platelet reactivity measuring platelet reactivity unit (PRU). The patients were classified as extensive, intermediate, and poor metabolizers by cytochrome P450 2C19 (CYP2C19) loss-of-function polymorphisms. The prevalence of IST was 9.0% by 9-month OCT, with no difference amongst the three groups (p = 0.886). The incidences of malapposed and uncovered struts were not different among the groups. PRU was not statistically different among the groups. In multivariate logistic regression analysis, the independent predictor for IST on 9-month OCT was irregular protrusion (odds ratio = 8.952, p = 0.037) on post-PCI OCT, not CYP2C19 loss-of-function polymorphisms. An adequate anti-thrombotic effect with an acceptable incidence of IST was observed irrespective of CYP2C19 loss-of-function polymorphisms. Our data suggests that adjusted-dose prasugrel and aspirin is a feasible treatment option in Japanese patients treated with EESs in elective PCI.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Cloridrato de Prasugrel/administração & dosagem , Trombose/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Aspirina/administração & dosagem , Doença da Artéria Coronariana/genética , Doença da Artéria Coronariana/metabolismo , Citocromo P-450 CYP2C19/genética , Citocromo P-450 CYP2C19/metabolismo , Everolimo/farmacologia , Feminino , Humanos , Japão , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Polimorfismo Genético , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Ticlopidina/administração & dosagem , Tomografia de Coerência Óptica
18.
J Electrocardiol ; 57: 87-89, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31522061

RESUMO

We present a patient with non-cardiac sarcoidosis complicated with manifest ventricular preexcitation. Initially, cardiac involvement of sarcoidosis was suspected from the echocardiographic findings showing localized hypokinesia at the left ventricular basal inferior wall. We, however, considered that the hypokinesia was a preexcitation-induced mechanical dyssynchrony rather than cardiac sarcoidosis, because polarities of the delta-waves indicated a left ventricular inferior accessory pathway. Temporal administration of oral flecainide acetate eliminated the basal left ventricular motion abnormality. Accordingly, we could successfully differentiate the mechanism of hypokinesia. In this context, we could rule out cardiac sarcoidosis, and initiation of glucocorticoid therapy was reasonably withheld.


Assuntos
Feixe Acessório Atrioventricular , Sarcoidose , Eletrocardiografia , Flecainida/uso terapêutico , Ventrículos do Coração , Humanos , Sarcoidose/complicações , Sarcoidose/diagnóstico , Sarcoidose/tratamento farmacológico
19.
Echocardiography ; 35(1): 110-113, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29151260

RESUMO

This case report is about an 85-year-old woman with bicuspid aortic stenosis (AS). Although preoperative multimodality imaging showed challenging anatomical aspects, transcatheter aortic valve replacement (TAVR) was selected to be performed as a less invasive alternative treatment approach, owing to her comorbidity. Postoperative transesophageal echocardiography and multidetector-row computed tomography revealed the presence of "locked-in leaflet" caused by stent distortion due to pinching by calcified native leaflets, with nodular calcification preventing the full expansion of the valve, which resulted in moderate perivalvular leakage. This is the first reported case of bicuspid AS treated with TAVR that eventually resulted in "locked-in leaflet."


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias/fisiopatologia
20.
Clin Anat ; 31(4): 525-534, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29542191

RESUMO

Knowledge of the anatomy of the membranous septum, as a surrogate to the location of the atrioventricular conduction axis, is a prerequisite for those undertaking transcatheter implantation of the aortic valve (TAVI). Equally important is its relationship of the virtual basal ring. This feature, however, has yet to be adequately described in the living heart. We analyzed computed tomographic angiographic datasets from 107 candidates (84.1 ± 5.2 years, 68% women) for TAVI. Using multiplanar reconstructions, we measured the height and width of the membranous septum, and the distances of its superior and inferior margins from the virtual basal ring plane. We also assessed the extent of wedging of the aortic root between the mitral valve and the ventricular septum. Mean heights and widths of the membranous septum were 6.6 ± 2.0, and 10.2 ± 3.1 mm, respectively, with its size significantly associated with that of the aortic root (P < 0.05). Its superior and inferior margins were 4.5 ± 2.3 and 2.1 ± 2.1 mm, respectively, from the plane of the basal ring. The inferior distance, the surrogate for the adjacency of the atrioventricular conduction axis, was ≤ 5mm in 91% of the patients. Deeper wedging of the aortic root was independently correlated with a shorter inferior distance (ß = 0.0569, P = 0.0258). The membranous septum is appreciably closer to the virtual basal ring than previously appreciated. These findings impact on estimations of the risk of damage to the atrioventricular conduction axis during TAVI. Clin. Anat. 31:525-534, 2018. © 2018 Wiley Periodicals, Inc.


Assuntos
Aorta/anatomia & histologia , Sistema de Condução Cardíaco/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA