RESUMO
Silicon (Si) photonics can have a major impact on the development of mid-IR photonics by leveraging on the reliable and high-volume fabrication technologies already developed for microelectronic integrated circuits. Germanium (Ge), already used in Si photonics, is a prime candidate to extend the operating wavelength of Group IV-based photonic integrated circuits beyond 8 µm, and potentially up to 15 µm. High performance quantum cascade lasers (QCLs) and interband cascade lasers grown on Si have been demonstrated, whereas no QCLs monolithically integrated on Ge have been reported yet. In this work, we present InAs-based QCLs directly grown on Ge by molecular beam epitaxy. The lasers emitting near 14 µm exhibited threshold current densities as low as 0.8-0.85 kA/cm2 at room temperature.
RESUMO
We investigate the impact of the growth conditions of AlGaAsSb cladding layers on the properties of interband cascade lasers (ICLs). For an optimized structure emitting at 3.3 µm, we achieve an internal quantum efficiency of 65% per stage in good agreement with conventional ICL using InAs/AlSb superlattice cladding layers, in spite of internal losses of 15 cm-1 due to higher optical losses in the n-type AlGaAsSb alloys. Finally, we report a narrow ridge ICL emitting at 3.33 µm operating in continuous wave up to 80°C that produces 1 mW/uncoated facet at 80 °C, 10 mW at 40 °C and more than 12 mW at 20°C.
RESUMO
We demonstrate surface enhanced infrared absorption spectroscopy using 1-dimensional highly doped semiconductors based on Si-doped InAsSb plasmonic nano-antennas. Engineering the plasmonic array to support the localized surface plasmon resonance aligned with the molecular vibrational absorption mode of interest involves finely setting the doping level and nano-antenna width. Heavily doped nano-antennas require a wider size compared to lightly doped resonators. Increasing the doping level, and consequently the width of the nano-antenna, enhances the vibrational absorption of a ~15 nm thick organic layer up to 2 orders of magnitude compared to the unstructured sample and therefore improves sensing. These results pave the way towards molecule fingerprint sensor manufacturing by tailoring the plasmonic resonators to get a maximum surface enhanced infrared absorption at the target vibrational mode.
RESUMO
We report a detailed analysis of the influence of the doping level and nanoribbon width on the localized surface plasmon resonance (LSPR) by means of reflectance measurements. The plasmonic system, based on one-dimensional periodic gratings of highly Si-doped InAsSb/GaSb semiconductor nanostructures, is fabricated by a simple, accurate and large-area technique fabrication. Increasing the doping level blueshifts the resonance peak while increasing the ribbon width results in a redshift, as confirmed by numerical simulations. This provides an efficient means of fine-tuning the LSPR properties to a target purpose of between 8-20 µm (1250-500 cm(-1)). Finally, we show surface plasmon resonance sensing to absorbing polymer layers. We address values of the quality factor, sensitivity and figure of merit of 16 700 nm RIU(-1) and 2.5, respectively. These results demonstrate Si-doped InAsSb/GaSb to be a low-loss/high sensitive material making it very promising for the development of biosensing devices in the mid-infrared.
RESUMO
This paper demonstrates a very compact wavelength meter for on-chip laser monitoring in the shortwave infrared wavelength range based on an optimized arrayed waveguide grating (AWG) filter with an integrated photodiode array. The AWG response is designed to obtain large nearest neighbor crosstalk (i.e. large overlap) between output channels, which allows accurately measuring the wavelength of a laser under test using the centroid detection technique. The passive AWG is fabricated on a 220 nm silicon-on-insulator (SOI) platform and is combined with GaInAsSb-based photodiodes. The photodiodes are heterogeneously integrated on the output grating couplers of the AWG using DVS-BCB adhesive bonding. The complete device with AWG and detectors has a footprint of only 2 mm(2) while the measured accuracy and resolution of the detected wavelength is better than 20pm.
RESUMO
We present a silicon-on-insulator (SOI) based spectrometer platform for a wide operational wavelength range. Both planar concave grating (PCG, also known as echelle grating) and arrayed waveguide grating (AWG) spectrometer designs are explored for operation in the short-wave infrared. In addition, a total of four planar concave gratings are designed to cover parts of the wavelength range from 1510 to 2300 nm. These passive wavelength demultiplexers are combined with GaInAsSb photodiodes. These photodiodes are heterogeneously integrated on SOI with benzocyclobutene (DVS-BCB) as an adhesive bonding layer. The uniformity of the photodiode characteristics and high processing yield, indicate a robust fabrication process. We demonstrate good performance of the miniature spectrometers over all operational wavelengths which paves the way to on-chip absorption spectroscopy in this wavelength range.
RESUMO
We present experimental studies on low-temperature ([Formula: see text]) carrier dynamics in (Ga,In)(Sb,Bi)/GaSb quantum wells (QWs) with the nominal In content of 3.7% and the Bi ranging from 6 to 8%. The photoreflectance experiment revealed the QW bandgap evolution with [Formula: see text] % Bi, which resulted in the bandgap tunability roughly between 629 and [Formula: see text], setting up the photon emission wavelength between 1.97 and [Formula: see text]. The photoluminescence experiment showed a relatively small 3-10[Formula: see text] Stokes shift regarding the fundamental QW absorption edge, indicating the exciton localisation beneath the QW mobility edge. The localised state's distribution, being the origin of the PL, determined carrier dynamics in the QWs probed directly by the time-resolved photoluminescence and transient reflectivity. The intraband carrier relaxation time to the QW ground state, following the non-resonant excitation, occurred within 3-25[Formula: see text] and was nearly independent of the Bi content. However, the interband relaxation showed a strong time dispersion across the PL emission band and ranging nearly between 150 and [Formula: see text], indicating the carrier transfer among the localised state's distribution. Furthermore, the estimated linear dispersion variation parameter significantly decreased from [Formula: see text] to [Formula: see text] with increasing the Bi content, manifested the increasing role of the non-radiative recombination processes with Bi in the QWs.
RESUMO
Two-stroke mopeds are a popular and convenient mean of transport in particular in the highly populated cities. These vehicles can emit potentially toxic gaseous and aerosol pollutants due to their engine technology. The legislative measurements of moped emissions are based on offline methods; however, the online characterization of gas and particulate phases offers great possibilities to understand aerosol formation mechanism and to adapt future emission standards. The purpose of this work was to study the emission behavior of two mopeds complying with different European emission standards (EURO-1 and EURO-2). A sophisticated set of online analyzers was applied to simultaneously monitor the gas phase and particulate phase of exhaust on a real time basis. The gaseous emission was analyzed with a high resolution Fourier transform infrared spectrometer (FTIR; nitrogen species) and a resonance-enhanced multiphoton ionization time-of-flight mass spectrometer (REMPI-ToF-MS; polycyclic aromatic hydrocarbons: PAH), whereas the particulate phase was chemically characterized by a high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS; organic, nitrate and chloride aerosol) and a multiangle absorption photometer (MAAP; black carbon). The physical characterization of the aerosol was carried out with a condensation particle counter (CPC; particle number concentration) and a fast mobility particle sizer (FMPS; size distribution in real time). In order to extract underlying correlation between gas and solid emissions, principal component analysis was applied to the comprehensive online dataset. Multivariate analysis highlighted the considerable effect of the exhaust temperature on the particles and heavy PAH emissions. The results showed that the after-treatment used to comply with the latest EURO-2 emission standard may be responsible for the production of more potentially harmful particles compared to the EURO-1 moped emissions.