Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Dig Dis Sci ; 65(8): 2433-2441, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31732907

RESUMO

BACKGROUND: The purpose of this study was to assess the value of functional MRI (fMRI) of post-doxorubicin drug-eluting beads transcatheter arterial chemoembolization (DEB-TACE) for hepatocellular carcinoma (HCC) as an early imaging biomarker of response to therapy. METHODS: This prospective analysis included 21 consecutive patients undergoing fMRI before and after DEB-TACE at a single medical center from January 2013 to December 2014. Functional MRI, including relative changes in apparent diffusion coefficient (ADC) and choline levels measured at hydrogen-1 magnetic resonance spectroscopy (MRS) of treated lesions, was recorded at baseline before DEB-TACE, and at 1, 2, and 4 weeks after DEB-TACE therapy. Assessment of tumor response was based on dynamic contrast-enhanced computer tomography imaging response according to modified response evaluation criteria in solid tumors. RESULTS: At post-therapy, 76% (n = 16) of patients demonstrated objective tumor response, 10% (n = 2) had stable disease, and 3 (14%) had progressive disease. Stable disease and progressive disease were designated as non-response. At week 2, the mean change in ADC value of responsive tumors was 0.35 ± 0.24 mm2/s, which was greater than that of non-response tumors (mean 0.01 ± 0.13 × 10-3 mm2/s) (P = 0.006). Significant differences were found in mean choline/water ratio between responsive (7.8 ± 4.9 × 10-3) and non-responsive (17.2 ± 4.9 × 10-3) tumors (P = 0.005). Composite scores of choline/water ratio and relative change of ADC showed significantly better diagnostic accuracy in non-responsive tumors than responsive tumors (area under the curve = 1.0; P < 0.001). CONCLUSIONS: Combined DWI and MRS may be used as an early imaging biomarker of therapy response in HCC patients after chemoembolization therapy.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Quimioembolização Terapêutica , Doxorrubicina/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Carcinoma Hepatocelular/terapia , Feminino , Humanos , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos
2.
J Formos Med Assoc ; 116(5): 380-387, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27659552

RESUMO

BACKGROUND/PURPOSE: To assess the risk factors for intractable and controllable postpartum hemorrhage (PPH) and to evaluate the safety, efficacy, and outcome of transcatheter arterial embolization (TAE). METHODS: An emergency PPH rescue system including the 24-hour-available TAE was established in 2004. TAE with gelatine sponge particles placed on bilateral uterine or internal iliac arteries served as the first-line treatment for intractable PPH. Delivery methods, parity, causes of bleeding, clinical vital signs, coagulopathy, success rate, resumption of menstruation, and subsequent pregnancy outcome after TAE were recorded. RESULTS: From the years 2005 to 2013, 301 women experienced PPH, of whom 178 had controllable PPH and 123 intractable PPH. Tachycardia and disseminated intravascular coagulation were significant risk factors for intractable PPH. All of the women with intractable PPH underwent TAE, and 89 (72.3%) were transferred by ground transport to receive treatment in this system. The mean travel distance was 15 km ± 12.5 km. The mean time of order to angiography room was 24.9 minutes ± 14.2 minutes. The mean blood loss before TAE was 2247 mL ± 1482 mL (range, 900-11,110 mL). The first TAE successfully controlled bleeding in 118 of the 123 (95.9%) women with intractable PPH. Of the 70 women with complete follow-up, 69 (98.6%) recovered menstruation. Twenty-three women tried to get pregnant and 19 (82.6%) of them succeeded, giving birth to 12 full-term live infants. CONCLUSION: TAE was safe and effective in treating intractable primary PPH with a high success rate and preservation of menstruation and fertility.


Assuntos
Embolização Terapêutica/métodos , Hemorragia Pós-Parto/terapia , Embolização da Artéria Uterina/métodos , Adulto , Feminino , Fertilidade , Humanos , Artéria Ilíaca/fisiopatologia , Transferência de Pacientes , Hemorragia Pós-Parto/fisiopatologia , Gravidez , Estudos Retrospectivos , Resultado do Tratamento , Artéria Uterina/fisiopatologia
3.
Eur J Radiol ; 177: 111551, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38875747

RESUMO

BACKGROUND: Liver transplantation is an effective treatment for preventing hepatocellular carcinoma (HCC) recurrence. This retrospective study aimed to quantitatively evaluate the attenuation in Hounsfield units (HU) on contrast-enhanced computed tomography (CECT) as a prognostic factor for hepatocellular carcinoma (HCC) following liver transplantation as a treatment. Our goal is to optimize its predictive ability for early tumor recurrence and compare it with the other imaging modality-positron emission tomography (PET). METHODS: In 618 cases of LDLT for HCC, only 131 patients with measurable viable HCC on preoperative CECT and preoperative positron emission tomography (PET) evaluations were included, with a minimum follow-up period of 6 years. Cox regression models were developed to identify predictors of postoperative recurrence. Performance metrics for both CT and PET were assessed. The correlation between these two imaging modalities was also evaluated. Survival analyses were conducted using time-dependent receiver operating characteristic (ROC) curve analysis and area under the curve (AUC) to assess accuracy and determine optimized cut-off points. RESULTS: Univariate and multivariate analyses revealed that both arterial-phase preoperative tumor attenuation (HU) and PET were independent prognostic factors for recurrence-free survival. Both lower arterial tumor enhancement (Cut-off value = 59.2, AUC 0.88) on CT and PET positive (AUC 0.89) increased risk of early tumor recurrence 0.5-year time-dependent ROC. Composites with HU < 59.2 and a positive PET result exhibited significantly higher diagnostic accuracy in detecting early tumor recurrence (AUC = 0.96). CONCLUSION: Relatively low arterial tumor enhancement values on CECT effectively predict early HCC recurrence after LDLT. The integration of CT and PET imaging may serve as imaging markers of early tumor recurrence in HCC patients after LDLT.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Transplante de Fígado , Doadores Vivos , Recidiva Local de Neoplasia , Tomografia Computadorizada por Raios X , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Masculino , Feminino , Recidiva Local de Neoplasia/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Meios de Contraste , Adulto , Idoso , Análise de Sobrevida , Valor Preditivo dos Testes , Prognóstico
4.
J Matern Fetal Neonatal Med ; 36(2): 2243366, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37586890

RESUMO

BACKGROUND: To describe and explore the risk factors, clinical presentations, timely diagnostic approaches, and management in patients experiencing unscarred uterine rupture with catastrophic hemorrhage. METHODS: We retrospectively analyzed clinical and imaging data from women who encountered postpartum hemorrhage (PPH) and were diagnosed with unscarred uterine rupture within a three-year timeframe (2018-2020). The data were extracted from medical records obtained from a multi-hospital 24-hour emergency PPH transfer system. RESULTS: Six patients were identified as having unscarred uterine rupture after vaginal delivery. All six women were para 2, with four of them undergoing vacuum-assisted delivery. One patient experienced out-of-hospital cardiac arrest (OHCA), while five patients presented with hypovolemic shock. Abdominopelvic ultrasound revealed a boggy lower uterine segment. Initially, five patients underwent transarterial embolization (TAE) of the internal iliac arteries in an attempt to achieve hemostasis, but this approach proved unsuccessful. Abdominopelvic computed tomography (CT) confirmed the diagnosis of ruptured uterus by demonstrating disrupted myometrium and hemoperitoneum. Immediate exploratory laparotomy followed by life-saving hysterectomy was performed in all cases. The median estimated total blood loss was 2725 mL ± 900 mL (ranging from 1600 mL to 7100 mL). Lower segment lacerations were observed in all patients, with more extensive uterine damage noted in those who underwent vacuum extraction. The length of hospital stay varied between 9 and 38 days. CONCLUSION: Instrument-assisted obstetric delivery is a possible contributing factor to unscarred uterine rupture in our study. In specific cases, the use of abdominopelvic CT prior to initiating transarterial embolization (TAE) offers valuable information to complement ultrasound findings. This comprehensive approach helps in accurately identifying the underlying cause of intractable postpartum hemorrhage (PPH). Immediate conversion to laparotomy is essential to explore the intra-abdominal factors causing PPH that cannot be controlled by TAE. The rational etiologies of uterine rupture must be clarified while generating practical guideline in the future.


Assuntos
Hemorragia Pós-Parto , Ruptura Uterina , Gravidez , Humanos , Feminino , Hemorragia Pós-Parto/diagnóstico , Hemorragia Pós-Parto/etiologia , Hemorragia Pós-Parto/terapia , Ruptura Uterina/diagnóstico , Ruptura Uterina/terapia , Estudos Retrospectivos , Parto Obstétrico/efeitos adversos , Hemoperitônio
5.
Transplant Proc ; 55(7): 1638-1643, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37391329

RESUMO

BACKGROUND: It may be difficult for pediatric patients to evaluate the impact of liver transplantation (LT) on splenomegaly due to the natural growth course. The long-term dynamics of portal vein (PV) size and PV flow after LT in pediatric patients are unclear. We aimed to evaluate the long-term transition of the splenic size, PV size, and PV flow velocity in pediatric patients who underwent successful living donor liver transplantation (LDLT) and survived >10 years. METHODS: From October 2004 to December 2010, 39 pediatric patients (25 boys; 14 girls) underwent LDLT, received pre-LDLT and post-LDLT computed tomography scans and long-term ultrasound sonography follow-up, and survived >10 years without additional intervention at our institution. We analyzed the short- to mid-term and long-term impact of LDLT on splenic size, PV size, and PV flow velocity over time. RESULTS: The PV diameter increased throughout the 10-year follow-up (P < .001). The PV flow velocity increased 1 day after LDLT (P< .001); proceeded to decrease 3 days after LDLT, reaching a low point 6 to 9 months after LDLT; and remained stable throughout the 10-year follow-up. Regression of the splenic volume at 6 to 9 months after LDLT (P < .001) was noted. However, the splenic size steadily increased on long-term follow-up. CONCLUSIONS: Although LDLT has a significant short-term reduction effect on splenomegaly, the long-term transitional trend of the splenic size and PV diameter may increase along with children's growth. The PV flow reached a stable status 6 to 9 months after LDLT and remained so until 10 years after LDLT.


Assuntos
Transplante de Fígado , Masculino , Feminino , Criança , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Seguimentos , Doadores Vivos , Estudos Retrospectivos , Esplenomegalia/diagnóstico por imagem , Esplenomegalia/etiologia , Esplenomegalia/cirurgia , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Resultado do Tratamento
6.
J Hepatocell Carcinoma ; 10: 81-90, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36685112

RESUMO

Purpose: To evaluate treatment response, survival and safety of a novel TACE using combination of ethanol-Lipiodol mixture and drug-eluting beads in patients with large unresectable HCC, single tumor >8 cm or multiple tumors with the largest tumor diameter >5 cm and total tumor diameter >10 cm. Patients and Methods: Between June 2016 and February 2020, a total of 27 patients were enrolled in this retrospective cohort study. Treatment response was assessed at first month after the treatment; progression-free survival (PFS) and overall survival (OS) were evaluated. The prognostic factors associated with patient survival were statistically analyzed by the Cox regression model. Adverse events were recorded. Results: The maximum diameter of the tumors ranged from 5 cm to 17 cm (mean 10.48 cm). The objective response and disease control rates were 56% and 78%, respectively, at 1-month follow-up. The median survival time was 15.9 months (95% CI, 9.03-34.76 months). The OS rates were 76.9% at six months, 65.2% at one year and 44.8% at two years. AFP >400 ng/mL (p = 0.0306), maximum tumor size >10cm (p = 0.0240) were potential risk factors for OS. Regarding safety, major complications occurred in one patient (1/27, 3.7%), presenting with transient hepatic encephalopathy. Conclusion: Combined DEB-TACE appeared to have favorable objective tumor response. It can be an effective treatment option for large unresectable HCC.

7.
J Hepatocell Carcinoma ; 10: 17-26, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36660410

RESUMO

Background: The purpose of this study was to assess the safety and efficacy of Yttrium-90 radioembolization using in unresectable hepatocellular carcinoma. Methods: From 2017 to 2021, 32 patients with unresectable hepatocellular carcinoma, with mean tumor diameter about 7cm (21 males, 11 females; median age, 57.5 years of age), treated with Yttrium-90 radioembolization using resin microspheres were reviewed at pre-Yttrium-90 and post-Yttrium-90 follow-up. Tumor response was assessed according to the modified Response Evaluation Criteria in Solid Tumors. Outcomes including overall survival and progression-free survival were reported. Results: Median follow-up was 18 months. At follow-up examinations at 3-, 6-, and 12-months follow-up, the overall survival rates were 94%, 87% and 59%, and the progression-free survival rates were 78%, 64% and 60%, respectively. Complete response, partial response, stable disease, and progressive disease were noted in 7 (21.9%), 14 (43.7%), 4 (12.5%), and 7 (21.9%) patients, respectively. The disease control rate was 78.1%, the objective response rate was 65.6%, and the successful downstage rate was 34.4% (11 of 32). Nine of thirty-two patients underwent resection or transplantation after Yttrium-90 radioembolization with 2-year overall survival being 100%. No serious adverse events occurred after Yttrium-90 treatment. Worse overall survival was related to the larger tumor, higher stage, Eastern Cooperative Oncology Group performance status, and Child-Pugh score. And worse progression-free survival was related to the higher tumor burden, and pre-Yttrium-90 serum α-fetoprotein level >100. Conclusion: Yttrium-90 Radioembolization can control hepatocellular carcinoma well even in advanced diseases. Patients successfully downstaging/bridging to resection or transplantation have excellent overall survival.

8.
Clin Transplant ; 26(2): E143-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22432787

RESUMO

In living donor liver transplantation (LDLT), the essential aims are to provide an adequate graft volume to the recipient and to keep a sufficient remnant liver volume in the donor. In some instances, these aims cannot be met by a single donor and LDLT using dual grafts from two donors is a good solution. From 2002 to 2009, five recipients in our hospital received dual graft LDLT. Two recipients received one right lobe and one left lobe grafts; the other three received two left lobe grafts. The mean final liver regeneration rate was 91.2%. Left lobe graft atrophy in the long term was observed in recipients who received a right and a left lobe grafts. The initial bigger volume graft in all recipients was noted to have better regeneration than the smaller volume grafts. Portal flow and bilateral grafts volume size discrepancy were considered as two major factors influencing graft regeneration in this study. We also noted that the initial graft volume correlated with portal flow in the separate grafts and finally contribute to individual graft regeneration. Because of compensatory hypertrophy of the other graft, recipients who experienced atrophy of one graft did not show signs of liver dysfunction.


Assuntos
Regeneração Hepática , Transplante de Fígado/métodos , Doadores Vivos , Adulto , Humanos , Circulação Hepática , Transplante de Fígado/efeitos adversos , Sistema Porta , Fluxo Sanguíneo Regional , Coleta de Tecidos e Órgãos , Adulto Jovem
9.
Clin Transplant ; 26(5): 694-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22292888

RESUMO

Our aim is to evaluate the relationship and impact of right-lobe (RL) liver grafts procured with or without the middle hepatic vein (MHV) trunk and MHV tributary reconstruction on segmental regeneration of these grafts in adult living donor liver transplantation (ALDLT). Patients underwent primary ALDLT using a RL liver graft were divided into three groups according to graft type: with MHV tributary reconstruction (group I), without MHV tributary reconstruction (group II), and with inclusion of the MHV trunk (group III). The overall graft volume and the volumes of the anterior and posterior segments of the grafts six months post-transplant, evaluated using computed tomography, were calculated as the regeneration indices. Optimal regeneration of the RL liver graft was achieved in the three groups of patients. There was no significant difference in the regeneration indices between groups I (149.4%) and III (143.6%). However, in group II (112.4%) without MHV or tributary reconstruction, the anterior regenerative index was lower than the other two groups and exhibited transient prolonged hyperbilirubinemia. Segmental graft regeneration is maximized by adequate venous drainage. Inclusion of the MHV trunk or MHV tributary reconstruction influences segmental liver regeneration and preclude transient hyperbilirubinemia in the early post-liver transplant phase.


Assuntos
Hepatectomia , Veias Hepáticas/cirurgia , Regeneração Hepática , Transplante de Fígado/efeitos adversos , Fígado/cirurgia , Doadores Vivos , Adulto , Feminino , Seguimentos , Humanos , Fígado/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Prognóstico , Procedimentos de Cirurgia Plástica , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
10.
Diagn Interv Radiol ; 28(5): 478-485, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36218150

RESUMO

PURPOSE Intractable ascites (IA) is an uncommon but challenging complication after liver transplantation. Splenic artery embolization (SAE) modulates the splenic artery and regulates portal flow. This study aimed to evaluate the efficacy and safety of SAE using the Amplatzer vascular plug (AVP) versus coil embolization for post-living-donor liver transplantation (LDLT) IA. METHODS This retrospective study evaluated consecutive patients from 1 center who received LDLT (n=1410) between March 2006 and August 2019. The inclusion criteria for SAE were splenomegaly with IA after LDLT. RESULTS Totally 15 patients underwent SAE for post-LDLT IA. Eleven patients who received AVP embolization (age, 51.2 ± 15.1 years; range, 8-63 years; 5 men and 6 women) were compared with 4 patients receiving coil embolization (age, 30.8 ± 30.8 years; range, 1.5-63 years; 2 men and 2 women). AVP and coil embolization both significantly reduced portal vein hyperflow (plug/ coil; P <.001/.006) and decreased ascites volume (plug/coil; P <.003/.042). The benefits of AVP embolization included shorter procedure time (P =.029), significantly reduced splenic volume (P =.012), increased liver volume (P =.012), decreased spleen/liver ratio (P =.012), and improvement of pancytopenia (P =.008) due to secondary hypersplenism. No significant differences were found between the two groups in the length of hospital stay or complications such as splenic infarction, pancreatitis, or sepsis. CONCLUSION SAE using AVP and coil embolization provide effective and safe methods for managing patients with IA after LDLT. AVP embolization may be more efficient than coil embolization, providing more effective reduction of ascites volume and the advantages of shortened procedure time and improvement of hypersplenism.


Assuntos
Embolização Terapêutica , Hiperesplenismo , Transplante de Fígado , Adolescente , Adulto , Idoso , Ascite/diagnóstico por imagem , Ascite/etiologia , Ascite/terapia , Criança , Pré-Escolar , Embolização Terapêutica/métodos , Feminino , Humanos , Hiperesplenismo/complicações , Hiperesplenismo/terapia , Lactente , Recém-Nascido , Transplante de Fígado/efeitos adversos , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Artéria Esplênica/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem
11.
Transplant Proc ; 54(2): 403-405, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35022136

RESUMO

BACKGROUND: To evaluate the significance of portosystemic shunts and associated long-term outcomes in living donor liver transplant (LDLT) among pediatric patients. METHODS: Retrospective review of 121 pediatric patients who underwent LDLT between May 1994 and December 2015 at Taiwan Kaohsiung Chang Gung Memorial Hospital. Pre- and postoperative computed tomography images of the liver were reviewed, and portal vein complications were assessed. RESULTS: Ninety-seven pediatric patients were included in the study, and 70 had portosystemic shunts before transplant. Thirty-three patients have portal systemic shunt (PSS) 6 months after transplant (mean [SD] shunt size, 4.59 [1.98] mm). Thirty-seven patients' portosystemic shunts closed spontaneously (mean [SD] shunt size, 3.14 [1.06] mm). Smaller PSSs tend to close spontaneously with a cutoff point of 3.35 mm by receiver operating characteristic curve (P = .01). Patients with PSS have more portal vein complications than those without PSS (44.3% vs 11.1%, P = .02). Among PSS recipients, patients with portal vein complications tend to have larger PSS size (mean [SD], 4.14 [1.96] mm vs 3.59 [1.48] mm), although the difference is not statistically significant (P = .19). CONCLUSIONS: In pediatric patients, preoperative portosystemic shunts are significantly correlated with portal venous complications, some of which require minimal interventions after LDLT with good outcomes. Shunts larger than 3.35 mm tend to persist after transplant with increased portal venous complications.


Assuntos
Transplante de Fígado , Derivação Portossistêmica Transjugular Intra-Hepática , Criança , Humanos , Doadores Vivos , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Derivação Portossistêmica Cirúrgica/efeitos adversos , Derivação Portossistêmica Cirúrgica/métodos , Estudos Retrospectivos
12.
Transpl Int ; 24(3): e19-22, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21070387

RESUMO

Parenchymal pseudoaneurysm of the hepatic arteries with massive intraperitoneal bleeding is rare but a serious life-threatening complication when it occurs following liver transplantation. We report a case of an adult postliving donor liver transplant recipient who developed massive subcapsular bleeding combined with massive right pleural effusion from ruptured multiple small intrahepatic arteries, which developed from a pseudoaneurysm that was treated by hepatic arterial embolization. Successful embolization was performed via a percutaneous trans-catheter approach by depositing 20-25%N-butyl-2-cyanoacrylate (NBCA) through the multiple small intrahepatic arteries into the pseudoaneurysm. Complete occlusion of the feeding arteries and pseudoaneurysm cavity resulted to immediate cessation of bleeding. There was no re-bleeding; and normal liver graft function was noted postembolization. Hepatic arterial embolization with NBCA can be used as treatment for postliver transplant peripheral intrahepatic artery pseudoaneurysm bleeding.


Assuntos
Falso Aneurisma/terapia , Embolização Terapêutica/métodos , Embucrilato/uso terapêutico , Hemorragia/terapia , Transplante de Fígado/efeitos adversos , Idoso , Falso Aneurisma/etiologia , Embolização Terapêutica/efeitos adversos , Feminino , Artéria Hepática/cirurgia , Humanos , Doadores Vivos
13.
Sci Rep ; 11(1): 19247, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34584142

RESUMO

Despite technological and immunological innovations, living-donor liver transplant (LDLT) recipients still face substantial risk of postoperative complications. Sarcopenia is being recognized more and more as a biomarker that correlates with poor outcomes in surgical patients. The purpose of this study was to evaluate the relationship between sarcopenia and significant surgical complications in LDLT recipients. This retrospective review included patients who had received LDLT at our institute from 2005 to 2017. Sarcopenia was assessed using the psoas muscle index (PMI) in cross-sectional images. ROC curve analysis was used to determine the ability of PMI to predict postoperative complications. Correlations between major postoperative complications and sarcopenia were evaluated using regression analysis. A total of 271 LDLT recipients were included. No significant differences were found between PMI and major postoperative complications in male patients. Female recipients with major postoperative complications had significantly lower mean PMI values (P = 0.028), and the PMI cut-off value was 2.63 cm2/m2. Postoperative massive pleural effusion requiring pigtail drainage occurred more frequently in the sarcopenia group than in the non-sarcopenia group (P = 0.003). 1-, 3-, 5- and 10-year overall survival rates in female were significantly poorer in the sarcopenia group (n = 14) compared with the non-sarcopenia group (n = 108), at 92.9% versus 97.2%, 85.7% versus 95.4%, 85.7% versus 92.5% and 70.1 versus 82.0%, respectively (P = 0.041) and 94.6%, 89.9%, 85.9% and 78.5% in male patients. Sarcopenia is associated with a significantly higher risk of major postoperative complications in females. PMI and sarcopenia together are predictive of major postoperative complications and survival rates in female LDLT recipients.


Assuntos
Doença Hepática Terminal/cirurgia , Transplante de Fígado/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Sarcopenia/epidemiologia , Adulto , Doença Hepática Terminal/complicações , Doença Hepática Terminal/diagnóstico , Doença Hepática Terminal/mortalidade , Feminino , Humanos , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Sarcopenia/etiologia , Índice de Gravidade de Doença , Fatores Sexuais , Taxa de Sobrevida , Transplantados/estatística & dados numéricos
14.
Technol Health Care ; 28(S1): 3-11, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32364139

RESUMO

BACKGROUND: The air kerma radiation doses have gained much attention since the operating room interventional radiology is a place where medical staff are exposed to a fluoroscopy environment and gain a cumulative dose during the uterine artery embolization procedure. OBJECTIVE: We aimed to evaluate the radiation dose received by medical staff by applying a flat X-ray machine in the surgical room during uterine artery embolization. METHODS: An ATOM humanoid model was laid on the operating table and simulated a patient. The scattered radiation dose received by the radiologist, anesthetist and radiologic technologist was evaluated. The scintillation detector was adopted. The measurement points were 50 cm, 100 cm and 150 cm above the floor, representing the limbs, abdomen and thyroid level, respectively. We compared the X-rays under different tube voltages of 70, 80, and 90, respectively and frames per second (FPS) of 30, 15, and 7.5, respectively. We configured the dose level per pulse of 40 nGy with a fixed detector. RESULTS: In Section 1, when the tube voltage was 70 kVp and 7.5 FPS, the average radiation doses of limbs, abdomen and thyroid level was 0.48, 1.3 and 1.9 µSv/min respectively. When the tube voltage was 80 kVp and the fluoroscopy decreases from 30 FPS to 7.5 FPS, 58% of the radiation dose was reduced. When the tube voltage was 90 kVp, the radiation dose in the lead garment increased 31-177% in comparison to when the tube voltage was 80 kVp. Sections 2 and 3 were far away from the central ray, so the highest radiation dose 100 cm above the floor were 0.05 and 0.02 µSv/min. CONCLUSIONS: Lead garment can effectively reduce medical staff from occupational doses with an average attenuation rate of 90%. 80 kVp was most commonly used. Fluoroscopy 7.5 FPS was used 100 cm above the floor in A section and the lowest radiation dose was 1.33 µSv/min. The operator should decrease the duration of X-rays or adopt suspended lead shielding to decrease the radiation dose received by the operator. When kVp increases, the penetration increases. Decreasing FPS cannot decrease occupational doses of medical staff.


Assuntos
Exposição Ocupacional/análise , Doses de Radiação , Exposição à Radiação/análise , Radiologia Intervencionista/instrumentação , Embolização da Artéria Uterina/métodos , Fluoroscopia , Pessoal de Saúde , Humanos , Chumbo , Salas Cirúrgicas , Equipamento de Proteção Individual , Espalhamento de Radiação , Fatores de Tempo
15.
Diagn Interv Radiol ; 26(3): 230-235, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32352922

RESUMO

PURPOSE: We aimed to compare the safety and effectiveness of 100-300 µm versus 300-500 µm drug-eluting bead transarterial chemoembolization (DEB-TACE) and to investigate the impact of tumor and feeding artery size on treatment outcome of different particle sizes in the treatment of hepatocellular carcinoma (HCC). METHODS: This retrospective cohort study enrolled 234 consecutive patients who underwent TACE using 100-300 µm DEB (Group A, n=75) and 300-500 µm DEB (Group B, n=159) in a tertiary center between August 2012 and March 2017. Initial treatment response and adverse events were assessed using modified Response Evaluation Criteria in Solid Tumors (mRECIST) and National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) version 5.0, respectively. RESULTS: A total of 704 HCCs in 234 patients were evaluated. The average index tumor size was 3.8 cm. Multivariate analysis showed that tumor size, lobe involvement, particle size, and tumor location were significant predictive factors of complete response. The overall rate of complete response in groups A and B were 56.0% and 33.3% (P = 0.001), respectively. Group A had higher complete response rate than group B in the subgroup of BCLC B with tumor <3 cm (57.9% vs. 21.1%; P = 0.020) and subgroup of feeding artery ≥0.9 mm (55.2% vs. 30.9%; P = 0.014). There were fewer major complications in group A compared with group B (0% vs. 6.9%, P = 0.018). CONCLUSION: TACE with 100-300 µm DEB is associated with better initial treatment response and fewer major complications compared with 300-500 µm. Our study also highlights the impact of tumor characteristics on treatment outcome of different DEB size, which might help to select the optimal sphere size for TACE in the treatment of HCC.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/patologia , Preparações Farmacêuticas/administração & dosagem , Idoso , Angiografia Digital/métodos , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Critérios de Avaliação de Resposta em Tumores Sólidos , Estudos Retrospectivos , Segurança , Resultado do Tratamento , Carga Tumoral
16.
Ann Transplant ; 25: e924336, 2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32958738

RESUMO

BACKGROUND Early hepatic artery thrombosis (eHAT) is a severe arterial complication leading to biliary complications and graft failure in living donor liver transplantation (LDLT). This study sought to early identify the abnormal waveforms of eHAT by using intensive Doppler ultrasonography (DUS) after LDLT and to assess the clinical outcome in these eHAT patients. MATERIAL AND METHODS DUS for 419 adult LDLT recipients was performed twice after vascular anastomosis during liver transplantation and once a day at the bedside for at least 2 weeks. RESULTS Nine adult LDLT recipients with eHAT were identified by using bedside DUS with subsequent computed tomography angiography (CTA). All eHAT cases were noted in the first 2 weeks. Five patients with CTA findings of partial thrombus with the small visualized intrahepatic hepatic artery (HA) were treated with intravenous thrombolysis (IVT) (medical group). Another 4 patients with CTA findings of extrahepatic HA occlusion and nonvisualization of intrahepatic HAs were treated by arterial re-anastomosis (surgical group). The prevalence of long-term non-anastomotic biliary strictures was 33.3% in the surgical group. Intensive post-LDLT DUS is a convenient and sensitive tool for eHAT detection. CONCLUSIONS Subsequent CTA gives valid information on occluded arteries and associated findings, which impact decision-making and are correlated with patient outcome. Our protocol of DUS has high sensitivity and diagnostic accuracy for use in in eHAT patients with partial occlusion, and it can be applied for IVT treatment, avoiding the need for reoperation and preventing long-term biliary complications.


Assuntos
Arteriopatias Oclusivas/etiologia , Artéria Hepática/diagnóstico por imagem , Hepatopatias/cirurgia , Transplante de Fígado/efeitos adversos , Trombose/etiologia , Ultrassonografia Doppler/métodos , Adulto , Idoso , Arteriopatias Oclusivas/diagnóstico por imagem , Feminino , Humanos , Hepatopatias/diagnóstico por imagem , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombose/diagnóstico por imagem
17.
Eur J Radiol ; 129: 109078, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32447148

RESUMO

PURPOSE: To evaluate the effective doses received by donors and recipients, identify effective dose contributions, and make risk assessments. MATERIALS AND METHODS: It was a retrospective study. 100 Donors and 100 recipients were enrolled with an operative day from March 2016 to August 2017. The dose was analyzed for all radiation-related examinations over a period of 2 years, 1 year before and 1 year after the LDLT procedure. The effective doses of plain X-rays, CT, fluoroscopy, and nuclear medicine per patient were simulated by a Monte Carlo software, evaluated by the dose-length product conversion factors, evaluated by the dose-area product conversion factors, and evaluated by the activity conversion factors, respectively. The risks of radiation-induced cancer were assessed on the basis of the ICRP risk model. RESULTS: The median effective doses were 71 (range: 30-186) mSv for donors and 147 (32-423) mSv for recipients. The radiation examinations were mainly performed in the last three months of preoperative period to first month of postoperative period for recipients and donors. The HCC recipients received a higher effective dose, 195 (64-423) mSv, than those with other indications. The median radiation-induced cancer risk was 0.38 % in male and 0.48 % in female donors and was 0.50 % in male and 0.58 % in female recipients. CONCLUSION: Donors and recipients received a large effective dose, mainly from the CT scans. To reduce effective doses should be included in future challenges in some living donor liver transplants centers that often use CT examinations.


Assuntos
Transplante de Fígado/métodos , Doadores Vivos , Doses de Radiação , Radiografia/métodos , Radiografia/estatística & dados numéricos , Adulto , Feminino , Fluoroscopia/métodos , Fluoroscopia/estatística & dados numéricos , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
18.
Pediatr Transplant ; 13(8): 984-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19032411

RESUMO

LT is the definitive treatment option in the management of end-stage liver disease. Preoperative vascular evaluation plays an important role for a safe and successful operation in LDLT. The purpose of this study is to assess the usefulness and accuracy of CTA and MRA in evaluating vascular anomalies in BA patients undergoing LDLT. Images of CTA and MRA for preoperative vascular evaluation in 57 BA patients undergoing LDLT were reviewed with the operative and pathologic findings. All underwent preoperative CTA and MRA. Pathologic PV (n = 20), interruption of the retro-hepatic vena cava (n = 1), aberrant right HA from the SMA (n = 2) were confirmed during the transplant operation. The success rate of CTA and MRA in identifying vascular anomalies was 96% and 82%, respectively (p = 0.01). The IQR scores were 3.25 +/- 0.53 for CTA and 2.91 +/- 0.70 for MRA (p = 0.001). The sensitivity, specificity and accuracy of CTA were 85%, 97% and 93%, respectively; and for MRA, were 65%, 95% and 84%, respectively. CTA is superior than MRA in the preoperative evaluation of the vascular anatomy in pediatric BA LDLT candidates.


Assuntos
Atresia Biliar/cirurgia , Transplante de Fígado , Fígado/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , Cuidados Pré-Operatórios , Estudos Retrospectivos , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Ácidos Tri-Iodobenzoicos/administração & dosagem
19.
Cancer Imaging ; 19(1): 74, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31730015

RESUMO

BACKGROUND: Tumor recurrence is the major risk factor affecting post-transplant survival. In this retrospective study, we evaluate the prognostic values of magnetic resonance (MR) diffusion-weighted imaging (DWI) in liver transplantation for hepatocellular carcinoma (HCC). METHODS: From April 2014 to September 2016, 106 HCC patients receiving living donor liver transplantation (LDLT) were enrolled. Nine patients were excluded due to postoperative death within 3 months and incomplete imaging data. The association between tumor recurrence, explant pathologic findings, and DWI parameters was analyzed (tumor-to-liver diffusion weighted imaging ratio, DWIT/L; apparent diffusion coefficients, ADC). The survival probability was calculated using the Kaplan-Meier method. RESULTS: Sixteen of 97 patients (16%) developed tumor recurrence during the follow-up period (median of 40.9 months; range 5.2-56.5). In those with no viable tumor (n = 65) on pretransplant imaging, recurrence occurred only in 5 (7.6%) patients. Low minimum ADC values (p = 0.001), unfavorable tumor histopathology (p <  0.001) and the presence of microvascular invasion (p <  0.001) were risk factors for tumor recurrence, while ADCmean (p = 0.111) and DWIT/L (p = 0.093) showed no significant difference between the groups. An ADCmin ≤ 0.88 × 10- 3 mm2/s was an independent factor associated with worse three-year recurrence-free survival (94.4% vs. 23.8%) and overall survival rates (100% vs. 38.6%). CONCLUSIONS: Quantitative measurement of ADCmin is a promising prognostic indicator for predicting tumor recurrence after liver transplantation.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Transplante de Fígado/efeitos adversos , Recidiva Local de Neoplasia/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/métodos , Transplante de Fígado/estatística & dados numéricos , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Taxa de Sobrevida
20.
World J Gastroenterol ; 14(28): 4529-34, 2008 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-18680234

RESUMO

AIM: To describe the radiological findings of a macro-regenerative nodule (MRN) in the liver of pre-transplantation biliary atresia (BA) patients and to correlate it with histological findings. METHODS: Between August 1990 and November 2007, 144 BA patients underwent liver transplantation (LT) at our institution. The pre-transplantation computer tomograghy (CT) and magnetic resonance imaging (MRI) findings were reviewed and correlated with the post-transplantation pathological findings. RESULTS: Nine tumor lesions in 7 patients were diagnosed in explanted livers. The post-transplantation pathological findings showed that all the lesions were MRNs without malignant features. No small nodule was detected by either MRI or CT. Of the 8 detectable lesions, 6 (75%) were in the central part of the liver, 5 (63%) were larger than 5 cm, 5 (63%) had intra-tumor tubular structures, 3 (38%) showed enhancing fibrous septa, 3 (38%) had arterial enhancement in CT, one (13%) showed enhancement in MRI, and one (13%) had internal calcifications. CONCLUSION: Although varied in radiological appearance, MRN can be differentiated from hepatocellular carcinoma (HCC) in most of BA patients awaiting LT. The presence of an arterial-enhancing nodule does not imply that LT is withheld solely on the basis of presumed malignancy by imaging studies. Liver biopsy may be required in aid of diagnostic imaging to exclude malignancy.


Assuntos
Atresia Biliar/diagnóstico por imagem , Atresia Biliar/patologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Atresia Biliar/cirurgia , Biópsia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Diagnóstico Diferencial , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Transplante de Fígado , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA