Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Med Virol ; 95(12): e29313, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38100626

RESUMO

Autoantibodies against angiotensin-converting enzyme 2 (ACE2) are frequently reported in patients during coronavirus disease 2019 (COVID-19) with evidence for a pathogenic role in severe infection. However, little is known of the prevalence or clinical significance of ACE2 autoantibodies in late convalescence or following COVID-19 vaccination. In this study, we measured ACE2 autoantibodies in a cohort of 182 COVID-19 convalescent patients, 186 COVID-19 vaccine recipients, and 43 adolescents with post-mRNA vaccine myopericarditis using two ACE2 enzymatic immunoassays (EIAs). ACE2 IgM autoantibody EIA median optical densities (ODs) were lower in convalescent patients than pre-COVID-19 control samples with only 2/182 (1.1%) convalescents testing positive. Similarly, only 3/182 (1.6%) convalescent patients tested positive for ACE2 IgG, but patients with history of moderate-severe COVID-19 tended to have significantly higher median ODs than controls and mild COVID-19 patients. In contrast, ACE2 IgG antibodies were detected in 10/186 (5.4%) COVID-19 vaccine recipients after two doses of vaccination. Median ACE2 IgG EIA ODs of vaccine recipients were higher than controls irrespective of the vaccine platform used (inactivated or mRNA). ACE2 IgG ODs were not correlated with surrogate neutralizing antibody levels in vaccine recipients. ACE2 IgG levels peaked at day 56 post-first dose and declined within 12 months to baseline levels in vaccine recipients. Presence of ACE2 antibodies was not associated with adverse events following immunization including myopericarditis. One convalescent patient with ACE2 IgG developed Guillain-Barre syndrome, but causality was not established. ACE2 autoantibodies are observed in COVID-19 vaccine recipients and convalescent patients, but are likely innocuous.


Assuntos
COVID-19 , Miocardite , Adolescente , Humanos , COVID-19/prevenção & controle , Autoanticorpos , Vacinas contra COVID-19/efeitos adversos , Enzima de Conversão de Angiotensina 2 , Vacinação , Anticorpos Neutralizantes , Imunoglobulina G , Anticorpos Antivirais
2.
Lasers Med Sci ; 38(1): 145, 2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37347307

RESUMO

The purpose of the study was to determine the influence of preparation techniques on marginal adaptation and sealing of Biodentine™ and TotalFill® RRM bioceramic retrograde fillings. Fifty-two single-root teeth extracted for periodontal reasons were used. Root canals were instrumented using Reciproc Blue #25 and obturated using a single cone technique with an AH Plus® root canal sealer. Retrograde cavities were prepared with Piezomed device (Piezo), Er:YAG laser in short-pulse(SP) and quantum square pulse(QSP) modes and filled with Biodentine™ (BD) or TotalFill® RRM (TF). There were 6 groups (n=8): (1) Piezo BD, (2) Piezo TF, (3) SP BD, (4) SP TF, (5) QSP BD, and (6) QSP TF, and positive and negative controls (n=2). Micro-CT analysis was performed on two samples from each group. Percentage volumes of internal and external voids in apical 1.5 mm were determined. Rhodamine B dye leakage was done on six samples. The samples were cut longitudinally and examined under a stereomicroscope. Digital recordings were analyzed in ImageJ software. The deepest penetration of color in mm was recorded. The data were statistically analyzed using ANOVA and Duncan's test at the level of significance α=0.05. TotalFill® RRM performed significantly better than Biodentine™ in terms of sealing (p<0.05) and marginal adaptation, as evaluated by micro-CT. Sealing was significantly better in SP compared to QSP mode preparations (p<0.05). Differences between Piezomed and laser modes were not significantly different (p>0.05). Sealing was statistically significantly better with TotalFill® RRM compared to Biodentine™ and in Er:YAG SP preparations compared to Er:YAG QSP.


Assuntos
Infiltração Dentária , Lasers de Estado Sólido , Materiais Restauradores do Canal Radicular , Humanos , Lasers de Estado Sólido/uso terapêutico , Ultrassom , Microtomografia por Raio-X , Projetos de Pesquisa , Frequência Cardíaca , Preparo de Canal Radicular , Cavidade Pulpar
3.
J Evid Based Dent Pract ; 23(1S): 101796, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36707171

RESUMO

OBJECTIVE: Dentists use a large number of dental materials to treat patients, mainly for pain relief, improved oral function, and orofacial appearance purposes. These materials supposably have been clinically tested and registered before launching onto the market. In terms of clinical testing, despite various objective and subjective assessments that could be done, the dentist-centred outcomes and regulatory body requirements might not fully reflect the perspective of the patient. Thus, dental-patient reported outcomes (dPROs) might be useful in providing valuable self-perceived feedback to stakeholders across a long period of time about the materials... performances. METHODS AND RESULTS: This narrative review evaluated various assessment dPROs tools and their applications to contemporary dental materials, trying to link up basic materials science and biomechanics with the patients... reported outcomes. CONCLUSIONS: dPROs can eventually form a basis of value-based dentistry for dental materials that would be of importance in terms of research, regulatory and safety.


Assuntos
Materiais Dentários , Medidas de Resultados Relatados pelo Paciente , Humanos
4.
J Hum Evol ; 173: 103268, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36288639

RESUMO

Recent studies have shown that global variation in body proportions is more complex than previously thought as some traits formerly associated with climate adaptation are better explained by geographic proximity and neutral evolutionary forces. While the recent incorporation of quantitative genetic methodologies has improved understanding of patterns related to climate in Africa, Europe, and the Americas, Asia remains underrepresented in recent and historic studies of body form. As ecogeographic studies tend to focus on male morphology, potential sex differences in features influenced by climate remain largely unexplored. Skeletal measurements encompassing the dimensions of the skull, pelvis, limbs, hands, and feet were collected from male (n = 459) and female (n = 442) remains curated in 13 collections across seven countries in East Asia (n = 901). Osteological data were analyzed with sex and minimum temperature as covariates adjusted by autosomal single-nucleotide polymorphism population genetic distance using univariate Bayesian linear mixed models, and credible intervals were calculated for each trait. Analysis supports a relationship between specific traits and climate as well as providing the magnitude of response in both sexes. After accounting for genetic distance between populations, greater association between climate and morphology was found in postcranial traits, with the relationship between climate and the skull limited primarily to breadth measurements. Larger body size is associated with colder climates with most measurements increasing with decreased temperature. The same traits were not always associated with climate for males and females nor correlated with the same intensity for both sexes. The varied directional association with climate for different regions of the skeleton and between the sexes underscores the necessity of future ecogeographic research to holistically evaluate body form and to look for sex-specific patterns to better understand population responses to environmental stresses.


Assuntos
Clima , Crânio , Feminino , Masculino , Humanos , Teorema de Bayes , Crânio/anatomia & histologia , Deriva Genética , Clima Frio
5.
Clin Oral Implants Res ; 33(9): 886-899, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35770363

RESUMO

PURPOSE: To investigate the error accumulation and distribution through various stages of the digital workflow for complete-arch implant-supported framework fabrication. MATERIALS AND METHODS: A resin model of edentulous maxilla with 6 dental implants was scanned using an intraoral scanner for 10 times (Complete-digital group). Ten conventional gypsum casts were made and digitized by a laboratory scanner (Analogue-digital group). Five implant frameworks were designed and milled using CAD-CAM technique for each workflow. Inter-implant distances and angles of the resin model (reference) and frameworks were measured by a coordinate measuring machine, while the scans and virtual frameworks were examined by an inspection software. Effect of type of workflow and the individual stage on the accuracy of the frameworks were analysed by Two-way ANOVA. RESULTS: The expanded uncertainty of both workflows was ~150 µm and ~ 0.8°. The accuracy of the CAD stage was the highest. In the complete-digital workflow, the greatest distortion was found in the data acquisition stage, while in the analogue-digital workflow, it was found in the CAM stage. Compared with the analogue-digital group, the complete-digital group showed a significant higher precision in the first quadrant, but lower trueness in the second quadrant in data acquisition, and a significantly lower precision in the second quadrant at the CAD stage. CONCLUSIONS: Linear distortions of the complete-digital and analogue-digital workflows were clinically acceptable, while angular distortions were not. Distortions were generally derived from data acquisition and CAM stage. The CAD precision depended on the distortions derived from data acquisition. The complete-digital workflow was not as accurate as the analogue-digital in complete-arch implant rehabilitation.


Assuntos
Implantes Dentários , Boca Edêntula , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Imageamento Tridimensional
6.
Clin Oral Implants Res ; 33(3): 313-321, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34971468

RESUMO

OBJECTIVES: To compare 2 implant scan bodies with different geometry on the accuracy of the virtual alignment process in the digital workflow. MATERIALS AND METHODS: A master model of the edentulous maxilla with 6 implants and multiunit abutments (MUA) inserted was fabricated. Six dome-shaped and cuboidal scan bodies were mounted on the MUAs, respectively, and consecutively scanned by a laboratory scanner 10 times. The original scans were imported to a dental-specific CAD software and virtually aligned with the default CAD model in the implant library. Thus, 10 aligned models were created. Both the original scans and the aligned models were evaluated by an inspection software for deviation of the scan body surfaces, the centroids of scan body and MUA, the scan body center-axis, and the inter-MUA distances/angles. The two-sample T-test/Mann-Whitney U test were used to analyze the data with the level of significance set at 0.05. RESULTS: The cuboidal group showed significant greater deviations of the model surface (13.9 µm vs. 10.7 µm) and the MUA centroids (31.7 µm vs. 22.8 µm) but smaller deviation of the inter-MUA angle (0.047° vs. 0.070°) than those of the dome-shaped group (p < .05). No significant differences in the deviation of scan body centroids, center-axis, and the inter-MUA distances between the 2 groups were found. CONCLUSIONS: Virtual alignment of implant scan body affected the accuracy of the digital workflow for complete-arch implant-supported prostheses (up to ~30 µm/0.09°). Different geometries of the implant scan body could also influence the transfer accuracy in the CAD process.


Assuntos
Implantes Dentários , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Imageamento Tridimensional , Fluxo de Trabalho
7.
BMC Oral Health ; 22(1): 470, 2022 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-36335339

RESUMO

BACKGROUND: The aim of the study was to investigate whether the citric acid and rough surface have a synergistic effect leading to severe wear behavior of resin composite. MATERIALS AND METHODS: Disk-shaped (Ø15 × 1.5 mm) specimens of resin composite (n = 12) with different initial roughness were prepared. Reciprocating ball-on-flat wear tests were performed under distilled water and citric acid (pH = 5.5) respectively. The coefficient of friction (COF), wear volume loss, and duration of the running-in period were quantified to assess the wear performance. And the values were analyzed with one-way ANOVA (α = 0.05). Regression analysis was applied to examine the influence of Ra values and mediums on the wear data. The wear morphology was analyzed by scanning electron microscopy and a 3D profilometer. RESULTS: The average COF was higher in distilled water than in citric acid but was independent of the surface roughness. For the composite, the volume loss of worn area and running-in period increased with surface roughness when tested under distilled water. However, these increasing trends were not found in citric acid. All specimens exhibited mild wear behavior with low COF and less superficial abrasion in acidic medium. CONCLUSIONS: The effect of initial roughness on wear behavior depends on the medium. In distilled water, resin composites with high initial roughness exhibit a longer running-in time, which eventually leads to a significant increase in material loss. The adverse effects of high roughness can be alleviated by the lubrication of citric acid, which can maintain a mild wear behavior regardless of initial surface roughness.


Assuntos
Resinas Compostas , Água , Humanos , Propriedades de Superfície , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácido Cítrico
8.
Ann Surg Oncol ; 28(1): 363-375, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32572853

RESUMO

BACKGROUND: Surgeons are pursuing accurate head and neck reconstruction to enhance aesthetic and functional outcomes after oncologic resection. This study aimed to investigate whether accuracy of head and neck reconstruction is improved with the use of three-dimensionally (3D)-printed patient-specific surgical plates compared with conventional plates. METHODS: In this comparative study, patients were prospectively recruited into the study group (3DJP16) with 3D-printed patient-specific surgical plates. The patients in control group with conventional surgical plates were from a historic cohort in the same unit. The primary end point of the study was the accuracy of head and neck reconstruction. The secondary end points were accuracy of osteotomy, intraoperative blood loss, total operative time, and length of hospital stay. RESULTS: The study recruited of 33 patients, including 17 in the study group and 16 in the control group. The patients' baseline characteristics were similar between the two groups. The absolute distance deviation of the maxilla or mandible was 1.5 ± 0.5 mm in the study group and 2.1 ± 0.7 mm in the control group [mean difference, - 0.7 mm; 95% confidence interval (CI) - 1.1 to - 0.3; p = 0.003], showing superior accuracy of reconstruction for the patients with 3D-printed patient-specific surgical plates. Improved accuracy of reconstruction also was detected in terms of bilateral mandibular angles and bone grafts. Concerning the secondary end points, the accuracy of the osteotomy was similar in the two groups. No difference was found regarding intraoperative blood loss, total operative time, or length of hospital stay. CONCLUSIONS: This is the first study to prove that compared with conventional plates, 3D-printed patient-specific surgical plates improve the accuracy of oncologic head and neck reconstruction.


Assuntos
Reconstrução Mandibular , Procedimentos de Cirurgia Plástica , Cirurgia Assistida por Computador , Placas Ósseas , Humanos , Mandíbula/cirurgia , Impressão Tridimensional
9.
Am J Phys Anthropol ; 175(3): 718-730, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33772761

RESUMO

OBJECTIVES: The present work describes the status and contents of The Human Bone Collection of the Faculty of Dentistry at the University of Hong Kong. MATERIALS AND METHODS: The Collection originates from the 1980s and became officially established in 2017 for teaching and research purposes. Most of the Collection consists of unclaimed human remains of southern Chinese individuals exhumed from local cemeteries and donated to the Faculty in the last few decades. The demographic information was provided largely from burial records and forensic estimations. Since 2016, the Collection has undergone a process of reorganization into cranial and postcranial remains, followed by preservation procedures that included cleaning and classification. RESULTS: The Collection currently consists of remains belonging to about 368 individuals (243 males, 54 females, 71 unknown), with ages ranging from 0.8 to 90 years (mean 57.4 years). It comprises cranial remains belonging to 260 individuals (169 males, 39 females, 52 unknown), and postcranial remains belonging to 248 individuals (180 males, 42 females, 26 unknown). The preservation status ranges from poor to good, with the cranial remains better preserved than the postcranial elements. For a large number of individuals, ear ossicles, soil samples, and other materials are also available. DISCUSSION: The Collection is accessible to local and international institutions for teaching and research.


Assuntos
Restos Mortais , Crânio , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cemitérios , Criança , Pré-Escolar , Odontologia , Docentes , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Clin Oral Implants Res ; 32(12): 1466-1473, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34545614

RESUMO

OBJECTIVES: To develop a novel auxiliary device for improving the accuracy of intraoral implant scanning in the complete-edentulous arch. MATERIALS AND METHODS: A standard model of edentulous maxilla with six dummy implants was prepared. Scan bodies were attached to the model, which was scanned by a laboratory scanner. A simulated mucosa (Group 0), a resin base (Group 1), a resin base with a cuboidal reference block and 4 fiduciary spheres (Group 2) or artificial teeth (Group 3) in between the implants were mounted on the model, respectively. Each group were consecutively scanned using an intraoral scanner (n = 10). The scans were analysed for trueness and precision in inter-implant distances and angles by inspection software. Effects of the auxiliary device and different quadrants on the accuracy of complete-arch intraoral scanning were analysed by two-way ANOVA. RESULTS: Significant effects of the auxiliary device and quadrant were found on both linear and angular accuracies. The lowest linear accuracy was found in group 0. Group 1 and group 3 showed the best linear accuracy in quadrant 1 and quadrant 2, respectively. Group 2 showed the least angular precision among the three groups. CONCLUSIONS: The three designs of auxiliary devices significantly improved the accuracy of complete-arch intraoral implant scanning. The base-only design showed good scanning accuracy in a single quadrant, while the base with tooth-shaped landmarks design showed better accuracy in cross-arch. The fiduciary spheres might compromise the precision of scanning.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Imageamento Tridimensional , Modelos Dentários
11.
J Prosthet Dent ; 126(4): 512-522, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33008629

RESUMO

STATEMENT OF PROBLEM: Lithium disilicate (LD) is a popular dental ceramic and has been a focus of dental research. Nevertheless, a quantified literature analysis focusing on the research of lithium disilicate is lacking. PURPOSE: The purpose of this bibliometric analysis was to review the progress of research into lithium disilicate in dentistry, including the identification of contributing researchers, organizations, countries or regions, journals, and the analysis of high-impact keywords and research trending. MATERIAL AND METHODS: The search was carried out within the topic field of the Web of Science (WoS) database, collecting publications related to LD from between 1996 and 2019. Metadata including the titles, abstracts, keywords, authors, affiliations, countries or regions, and references were extracted. Bibliometric indicators in terms of documents, authors, journals, and keywords were analyzed. RESULTS: Between 1996 and 2019, the dental research on LD trended upward. Scholars in the United States, Germany, Switzerland, and Brazil actively participated in the research on LD, and publications from the United States had the most citations. The Journal of Prosthetic Dentistry and Dental Materials were the major contributing journals. High-impact terms could be categorized into types of restorative material, types of prostheses, and properties or techniques of materials. Co-occurrence and relative normalized citation analysis of keywords highlighted several research interests, such as comparison studies between LD and zirconia, computer-aided design and computer-aided manufacturing (CAD-CAM) techniques, and the performance of complete coverage LD restorations. CONCLUSIONS: With the global upsurge in research on lithium disilicate, extensive collaborations and citations have been noted among authors, institutions, and countries or regions. Research hotspots include types of restorative material, types of prostheses, and properties or techniques of materials.


Assuntos
Coroas , Porcelana Dentária , Bibliometria , Cerâmica , Desenho Assistido por Computador , Teste de Materiais
12.
J Clin Pediatr Dent ; 44(5): 332-341, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33181840

RESUMO

OBJECTIVE(S): To: 1) examine the fluoride concentrations in commercial child formula dentifrices (CFD)s; and 2) investigate the effect of arginine incorporation in CFDs on fluoride bioavailability. STUDY DESIGN: Five commercial CFDs were examined for fluoride concentrations. Total, total soluble, and insoluble fluorides in CFDs were determined by the modified Taves acid-diffusion method (TAD). Ionic F and MFP were estimated by modified direct method with standard addition technique. L-arginine (L-Arg)/L-arginine monohydrochloride (L-Arg.HCl) were incorporated at 2% w/w in the commercial CFDs. The pH of the toothpaste slurries, buffer capacity of the added Arg, potentially available fluorides (PAF) and 1-min PAF by TAD were determined. RESULTS: The CFDs had 4 to 32% of insoluble fluorides. Addition of L-Arg/L-Arg.HCl significantly improved the fluoride bioavailability in CFDs (p<0.05). Incorporation of L-Arg significantly increased the pH of toothpaste slurries (p<0.05); while L-Arg.HCl decreased the pH. Principal component analysis showed that L-Arg.HCl decreased the pH of toothpaste slurries due to the presence of Cl in the form of HCl; whereas the inherent elements/molecules (Na/P/Pi/F) remain distinct with unidentified influence on the variables. CONCLUSION(S): The CFDs containing NaF only have higher concentrations of bioavailable fluoride. Incorporating arginine (L-arginine or L-arginine monohydrochloride) at 2% w/w improves fluoride bioavailability of the child formula dentifrices.


Assuntos
Dentifrícios , Fluoretos , Arginina , Disponibilidade Biológica , Cariostáticos , Criança , Humanos , Fosfatos , Fluoreto de Sódio , Cremes Dentais
13.
Clin Oral Implants Res ; 26(3): 332-41, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24450938

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the effect of novel silane system coatings on zirconia and titanium implant surfaces and the attachment of the fungal pathogen Candida albicans. MATERIALS AND METHODS: Titanium and zirconia specimens were silica-coated and silanized either with a commercial silane primer (RelyX Ceramic Primer™, 3M ESPE) or a novel silane system primer. The novel silane system primer was a blend of 1.0 vol% 3-acryloxypropyltrimethoxysilane and 0.3 vol% bis-1,2-(triethoxysilyl)ethane diluted in acidified ethanol-water solvent. The surface roughness (Ra ), the surface free energy and the chemical composition of substrate surfaces after treatments were evaluated. C. albcans biofilms were developed on silica-coated + silanized surfaces during 48 h of incubation time. Colony forming units (CFU) and real-time PCR (RT-PCR) quantified the cells on the material surfaces. Statistical analyses were carried out by 1-way ANOVA, Tukey post hoc and Games Howell post hoc test at 5% significance level (p). RESULTS: On zirconia and titanium surfaces, the Ra and the chemical composition of the specimens were equal (P < 0.05). The surface free energy was decreased on titanium specimens and increased on zirconia specimen after silanization. CFU of C. albicans was significantly lower on zirconia coated with RelyX Ceramic Primer™, (P < 0.001) and on titanium coated with both silanes (P = 0.002). RT-PCR revealed no differences between the mean quantities of C. albicans (P ≥ 0.067). CONCLUSION: Silica-coating and silanization had modified the titanium and zirconia surfaces significantly. Both the control and experimental silane primers might inhibit the biofilm formation of C. albicans.


Assuntos
Candida albicans , Adesão Celular/fisiologia , Materiais Revestidos Biocompatíveis/química , Implantes Dentários , Silanos/química , Titânio/química , Zircônio/química , Biofilmes , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Reação em Cadeia da Polimerase em Tempo Real , Cimentos de Resina , Células-Tronco , Propriedades de Superfície
14.
J Prosthet Dent ; 114(3): 440-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26013069

RESUMO

STATEMENT OF PROBLEM: Fluorophlogopite glass ceramic (FGC) is a biocompatible, etchable, and millable ceramic with fluoride releasing property. However, its mechanical properties and reliability compared with other machinable ceramics remain undetermined. PURPOSE: The purpose of this in vitro study was to compare the mechanical properties of 3 commercially available millable ceramic materials, IPS e.max CAD, Vitablocs Mark II, and Vita Enamic, with an experimental FGC. MATERIAL AND METHODS: Each type of ceramic block was sectioned into beams (n=15) of standard dimensions of 2×2×15 mm. Before mechanical testing, specimens of the IPS e.max CAD group were further fired for final crystallization. Flexural strength was determined by the 3-point bend test with a universal loading machine at a cross head speed of 1 mm/min. Hardness was determined with a hardness tester with 5 Vickers hardness indentations (n=5) using a 1.96 N load and a dwell time of 15 seconds. Selected surfaces were examined by scanning electron microscopy and energy-dispersive x-ray spectroscopy. Data were analyzed by the 1-way ANOVA test and Weibull analysis (α=.05). Weibull parameters, including the Weibull modulus (m) as well as the characteristic strength at 63.2% (η) and 10.0% (B10), were obtained. RESULTS: A significant difference in flexural strength (P<.001) was found among groups, with IPS e.max CAD (341.88 ±40.25 MPa)>Vita Enamic (145.95 ±12.65 MPa)>Vitablocs Mark II (106.67 ±18.50 MPa), and FGC (117.61 ±7.62 MPa). The Weibull modulus ranged from 6.93 to 18.34, with FGC showing the highest Weibull modulus among the 4 materials. The Weibull plot revealed that IPS e.max CAD>Vita Enamic>FGC>Vitablocs Mark II for the characteristic strength at both 63.2% (η) and 10.0% (B10). Significant difference in Vickers hardness among groups (P<.001) was found with IPS e.max CAD (731.63 ±30.64 H(V))>Vitablocs Mark II (594.74 ±25.22 H(V))>Vita Enamic (372.29 ±51.23 H(V))>FGC (153.74 ±23.62 H(V)). CONCLUSIONS: The flexural strength and Vickers hardness of IPS e.max CAD were significantly higher than those of the 3 materials tested. The FGC's flexural strength was comparable with Vitablocs Mark II. The FGC's Weibull modulus was the highest, while its Vickers hardness was the lowest among the materials tested.


Assuntos
Silicatos de Alumínio/química , Cerâmica/química , Porcelana Dentária/química , Zircônio/química , Análise do Estresse Dentário , Dureza , Humanos , Teste de Materiais , Maleabilidade , Reprodutibilidade dos Testes , Estresse Mecânico , Propriedades de Superfície
15.
Dent Mater ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38926013

RESUMO

OBJECTIVE: The commonly used base monomer utilized in resinous commercial dental restorative products is bis-GMA which is derived from bisphenol-A (BPA) - a well-known compound which may disrupt endocrine functions. To address concerns about its leaching into the oral environment and to optimize the quality of dental composites, a BPA-free alternative base monomer, fluorinated urethane dimethacrylate (FUDMA), was designed by modifying a UDMA monomer system. METHODS: Nine groups of composites were prepared by mixing the base monomers and TEGDMA in a ratio of 70/30 wt% to which were added silanized glass particles (mean diameter: 0.7 µm) in 3 different volume fractions (40, 45, and 50 vol%). Bis-GMA and UDMA base monomers were used as control groups in the same ratios. Various properties including degree of conversion (DC), flexural strength (FS) and flexural modulus (FM), water sorption (WS), solubility (SL), surface hardness and roughness, and initial adhesion property against S.mutans were investigated. One-way analysis of variance followed by Bonferroni test at α = 0.05 was used to analyze the results. RESULTS: A significant difference in FS between FUDMA-based composite with 40 vol% filler (120.3 ± 10.4 MPa) and Bis-GMA-based composite with the same filler fraction (105.8 ± 10.0 MPa) was observed but there was no significant difference among other groups. The UDMA based group exhibited the highest WS (1.3 ± 0.3 %). Bis-GMA showed greater initial bacterial adhesion but was not statistically different from the other groups (p = 0.082). SIGNIFICANCE: FUDMA-based resin composites exhibit comparable mechanical and bacterial adhesion properties compared with Bis-GMA and UDMA-based composites. The FUDMA composites show positive outcomes indicating they could be used as substitute composites to Bis-GMA-based composites.

16.
J Dent ; 146: 105031, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38710315

RESUMO

OBJECTIVES: To investigate and compare the chemical and optical stability of four restorative composite materials: two injectable resins, one flowable resin and one compomer. METHODS: Two injectable nano-filled composite resins: G-aenial Universal (GU) and Beautifil Injectable XSL (BI), a flowable composite resin: Filtek Supreme Flowable (FS) and a compomer: Dyract Flow (DF), in A2 shade were tested and compared. Water sorption and solubility were conducted according to ISO4049:2019 standard; ICP-OES and F-ion selective electrode were used to test the elemental release; Degree of conversion (DC) was obtained by using FTIR; water contact angle was obtained by static sessile drop method, and a spectrophotometer was used for optical properties (ΔE⁎, ΔL⁎ and TP). SPSS 28.0 was used for statistical analysis and the significant level was pre-set as α = 0.05. RESULTS: GU performed the best in water sorption and solubility, FS had the lowest elemental release, the best colour stability, and the highest DCIM and DC24-h. DF, the compomer had the lowest, and GU and BI, the injectable composites had the largest water contact angle, respectively. Correlations were found between water sorption and water solubility. CONCLUSIONS: The four composite restorative materials showed different chemical and optical behaviours. Overall, composite resins performed better than compomer, while additional laboratory and in vivo tests are necessary to obtain a more comprehensive comparison between injectable and flowable composite resins. Wsp and Wsl are influenced by many common factors, and the values are highly positively related. CLINICAL SIGNIFICANCE: A comprehensive understanding of materials is crucial before selecting materials for clinical practice. Composite resins rather than compomers are recommended because of their exceptional properties, which make them eligible for a wide range of clinical applications and an elongated lifespan.


Assuntos
Cor , Compômeros , Resinas Compostas , Materiais Dentários , Teste de Materiais , Solubilidade , Água , Resinas Compostas/química , Materiais Dentários/química , Água/química , Compômeros/química , Humanos , Restauração Dentária Permanente/métodos , Espectrofotometria , Espectroscopia de Infravermelho com Transformada de Fourier , Metacrilatos/química , Injeções , Poliuretanos/química , Nanocompostos/química , Propriedades de Superfície , Fenômenos Ópticos , Bis-Fenol A-Glicidil Metacrilato
17.
Dent J (Basel) ; 12(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38786540

RESUMO

This study aims to investigate whether toothbrushes with fluoride-infused bristles have any (re)mineralisation effects on bovine enamel. Bovine incisors (N = 160) were extracted, and the buccal side of the crown was cut into dimensions of ~5 mm × 5 mm with a low-speed saw. These specimens were randomly allocated into four groups: half (80 teeth) were stored in demineralising solution (DM), and the other half were stored in deionised water (DW) for 96 h. Then, they were brushed with a force of 2.0 ± 0.1 N for five min with a manual toothbrush with either fluoride-infused (TF) or regular (TR) bristles. Microhardness (Vickers), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS), and scanning electron microscopy (SEM) were used to investigate the surfaces of the bovine enamel specimens before and after brushing. Two-way ANOVA was used to analyse the hardness data, and the pairwise comparison method was used to analyse the Ca/P ratio, for each group at α = 0.05. The results show that brushing with either of these toothbrushes increased the Vickers microhardness on DM and DW enamel (p < 0.001), whereas hydroxyapatite was revealed in all groups by XRD. The DM samples showed a significant increase (p < 0.05) in the Ca/P ratios after brushing with TR and TF. Conversely, under DW conditions, these ratios decreased significantly after brushing. In terms of the F atomic%, TF increased significantly. SEM revealed mineral deposition in the DM groups after toothbrushing. To conclude, toothbrushing effectively induces the microhardness of sound and demineralised enamel, while fluoride-infused bristles might be able to retain fluoride on the enamel surface.

18.
J Dent ; 146: 105025, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38697507

RESUMO

OBJECTIVES: To evaluate the mechanical, wear, antibacterial properties, and biocompatibility of injectable composite materials. METHODS: Two injectable composite resins (GU and BI), one flowable composite resin (FS), and one flowable compomer (DF), in A2 shade, were tested. Mechanical properties were tested via three-point bending test immediately after preparation and after 1-day, 7-day, 14-day, and 30-day water storage. Under water-PMMA slurry immersion, specimens were subjected to a 3-body wear test (10,000 cycles) against stainless steel balls, while the roughness, wear depth, and volume loss were recorded. After 1-day and 3-day MC3T3-E1 cell culture, cell viability was evaluated with CCK-8 test kits, while the cell morphology was observed under CLSM and SEM. Antibacterial properties on S. mutans were assessed via CFU counting, CLSM, and SEM observation. SPSS 26.0 was used for statistical analysis (α = 0.05). RESULTS: The mechanical properties were material-dependent and sensitive to water storage. Flexural strength ranked GU > FS > BI > DF at all testing levels. Three nanocomposites had better wear properties than DF. No significant difference on 1-day cell viability was found, but DF showed significantly lower cell proliferation than nanocomposites on 3-day assessment. GU and FS had more favourable cell adhesion and morphology. CFU counting revealed no significant difference, while FS presented a slightly thicker biofilm and BI showed relatively lower bacteria density. CONCLUSIONS: Injectable nanocomposites outperformed the compomer regarding mechanical properties, wear resistance, and biocompatibility. The tested materials presented comparable antibacterial behaviours. Flowable resin-based composites' performances are affected by multiple factors, and their compositions can be attributed. CLINICAL SIGNIFICANCE: A profound understanding of the mechanical, wear, and biological properties of the restorative material is imperative for the clinical success of dental restorations. The current study demonstrated superior properties of highly filled injectable composite resins, which imply their wider indications and better long-term clinical performances.


Assuntos
Antibacterianos , Materiais Biocompatíveis , Sobrevivência Celular , Resinas Compostas , Teste de Materiais , Streptococcus mutans , Propriedades de Superfície , Resinas Compostas/química , Resinas Compostas/farmacologia , Antibacterianos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química , Camundongos , Animais , Sobrevivência Celular/efeitos dos fármacos , Materiais Dentários/química , Compômeros/farmacologia , Água/química , Nanocompostos/química , Resistência à Flexão , Injeções , Polimetil Metacrilato/química
19.
J Funct Biomater ; 15(5)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38786632

RESUMO

This study aims to develop multi-functional bio-safe dental resin composites with capabilities for mineralization, high in vitro biocompatibility, and anti-biofilm properties. To address this issue, experimental resin composites consisting of UDMA/TEGDMA-based dental resins and low quantities (1.9, 3.8, and 7.7 vol%) of 45S5 bioactive glass (BAG) particles were developed. To evaluate cellular responses of resin composites, MC3T3-E1 cells were (1) exposed to the original composites extracts, (2) cultured directly on the freshly cured resin composites, or (3) cultured on preconditioned composites that have been soaked in deionized water (DI water), a cell culture medium (MEM), or a simple HEPES-containing artificial remineralization promotion (SHARP) solution for 14 days. Cell adhesion, cell viability, and cell differentiation were, respectively, assessed. In addition, the anti-biofilm properties of BAG-loaded resin composites regarding bacterial viability, biofilm thickness, and biofilm morphology, were assessed for the first time. In vitro biological results demonstrated that cell metabolic activity and ALP expression were significantly diminished when subjected to composite extracts or direct contact with the resin composites containing BAG fillers. However, after the preconditioning treatments in MEM and SHARP solutions, the biomimetic calcium phosphate minerals on 7.7 vol% BAG-loaded composites revealed unimpaired or even better cellular processes, including cell adhesion, cell proliferation, and early cell differentiation. Furthermore, resin composites with 1.9, 3.8, and 7.7 vol% BAG could not only reduce cell viability in S. mutans biofilm on the composite surface but also reduce the biofilm thickness and bacterial aggregations. This phenomenon was more evident in BAG7.7 due to the high ionic osmotic pressure and alkaline microenvironment caused by BAG dissolution. This study concludes that multi-functional bio-safe resin composites with mineralization and anti-biofilm properties can be achieved by adding low quantities of BAG into the resin system, which offers promising abilities to mineralize as well as prevent caries without sacrificing biological activity.

20.
J Mech Behav Biomed Mater ; 155: 106543, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38636445

RESUMO

The potential of using specimens with a double-semicircular-notched configuration for performing tensile tests of orthodontic thermoplastic aligner materials was explored. Unnotched and double-semicircular-notched specimens were loaded in tension using a universal testing machine to determine their tensile strength, while finite element analysis (FEA) and digital image correlation (DIC) were used to estimate stress and strain, respectively. The shape did affect the tensile strength, demonstrating the importance of unifying the form of the specimen. During the elastic phase under tension, double-semicircular-notched specimens showed similar behavior to unnotched specimens. However, great variance was observed in the strain patterns of the unnotched specimens, which exhibited greater chance of end-failure, while the strain patterns of the double-semicircular-notched specimens showed uniformity. Considerable agreement between the theoretical (FEA) and practical models (DIC) further confirmed the validity of the double-semicircular-notched models.


Assuntos
Análise de Elementos Finitos , Teste de Materiais , Estresse Mecânico , Resistência à Tração , Teste de Materiais/instrumentação , Testes Mecânicos , Plásticos , Temperatura , Aparelhos Ortodônticos , Fenômenos Mecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA