Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Surg ; 226(6): 882-885, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37532591

RESUMO

INTRODUCTION: A Code White (CW) activation is a hospital-wide alert for postpartum hemorrhage (PPH) and acute care surgeons (ACS) were added to the response team to assist in resuscitation. A multidisciplinary training program was also implemented. This study aimed to evaluate the impact of ACS involvement and training on maternal outcomes. METHODS: A retrospective review was performed on all CW activations from 1/1/2015-8/31/2022. Three groups-pre-ACS response, ACS response, and ACS response â€‹+ â€‹training (R&T)-were compared. RESULTS: 218 patients had CW activations. ACS response increased MTP activations (50.0%vs76.5%vs76.2%, p â€‹= â€‹0.014) and TXA administration (50.0%vs96.5%vs93.3%, p â€‹< â€‹0.0001). The ACS R&T had the highest ACS presence (53.6%vs72.9%vs96.2%, p â€‹< â€‹0.0001), shortest operation (99 vs 67 vs 53min, p â€‹= â€‹0.002), lowest crystalloid use (2000 vs 1110 vs 800 â€‹ml, p â€‹= â€‹0.003), and lowest transfusion requirements. Mortality decreased from 17.9% in pre-ACS to 2.4% in ACS response and 0% in ACS R&T (p â€‹< â€‹0.0001). CONCLUSION: ACS assistance in CW activations and multidisciplinary PPH education led to the prevention of maternal mortality. ACS are a valuable resource in this unique population.


Assuntos
Hemorragia Pós-Parto , Cirurgiões , Gravidez , Feminino , Humanos , Hemorragia Pós-Parto/prevenção & controle , Mães , Estudos Retrospectivos , Transfusão de Sangue
2.
J Neurol Neurosurg Psychiatry ; 82(4): 373-6, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20826877

RESUMO

BACKGROUND: Hippocampal changes may be a useful biomarker for Alzheimer's disease if they are specific to dementia sub-type. We compare hippocampal volume and shape in population-based incident cases of Alzheimer's disease and vascular dementia (VaD). METHODS: Participants are Japanese-American men from the Honolulu Asia Aging Study. The following analysis is based on a sub-group of men with mild incident Alzheimer's disease (n=24: age=82.5 ± 4.6) or incident VaD (n=14: age=80.5 ± 4.5). To estimate hippocampal volume, one reader, blinded to dementia diagnosis, manually outlined the left and right formation of the hippocampus using published criteria. We used 3-D mapping methods developed at the Laboratory of Neuro Imaging (LONI) to compare regional variation in hippocampal width between dementia groups. RESULTS: Hippocampal volume was about 5% smaller in the Alzheimer's disease group compared to the VaD group, but the difference was not significant. Hippocampal shape differed between the two case groups for the left (p<0.04) but not right (p<0.21) hippocampus. The specific region of the hippocampus that most consistently differed between the Alzheimer's disease and VaD cases was in the lateral portion of the left hippocampus. Our interpretation of this region is that it intersects the CA1 sub-region to a great extent but also includes the dentate gyrus (and hilar region) and subiculum. CONCLUSION: As indicated by shape analysis, there are some differences in atrophy localisation between the Alzheimer's disease and VaD cases, despite the finding that volume of the hippocampi did not differ. These findings suggest hippocampal atrophy in Alzheimer's disease may be more focal than in VaD.


Assuntos
Doença de Alzheimer/patologia , Demência Vascular/patologia , Hipocampo/patologia , Idoso de 80 Anos ou mais , Atrofia/patologia , Mapeamento Encefálico/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
3.
Curr Opin Clin Nutr Metab Care ; 14(6): 635-41, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21892077

RESUMO

PURPOSE OF REVIEW: Obesity is a growing worldwide epidemic. Obese patients are often deficient in micronutrients despite macronutrient excess. Bariatric surgery is an increasingly utilized modality in the treatment of obesity and obesity-related conditions. Bariatric surgery itself may cause or exacerbate micronutrient deficiencies with serious sequelae. This review will focus on perioperative strategies to detect, prevent and treat micronutrient deficiencies in patients undergoing bariatric surgery, and will highlight practical and clinical aspects of these nutritional problems. RECENT FINDINGS: Micronutrient deficiency is common in obese patients undergoing bariatric surgery both preoperatively and postoperatively. Bariatric procedures with a malabsorptive component are more likely to result in postoperative micronutrient deficiency. A system-based approach will facilitate clinical suspicion of specific or combined micronutrient deficiencies, leading to appropriate laboratory tests for confirmation. Supplementation by the oral route is always tried first, reserving parenteral administration for specific situations. SUMMARY: Clinicians should be aware that micronutrient deficiencies are common in obese patients who may have macronutrient excess. Micronutrient deficiency may exist preoperatively or be caused by bariatric procedures themselves. A systematic and team-based approach will decrease morbidity associated with delays in diagnosis and treatment.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Suplementos Nutricionais , Desnutrição/prevenção & controle , Micronutrientes/deficiência , Obesidade/epidemiologia , Administração Oral , Cirurgia Bariátrica/métodos , Gerenciamento Clínico , Humanos , Desnutrição/etiologia , Micronutrientes/administração & dosagem , Obesidade/cirurgia , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios/métodos
4.
IEEE Trans Vis Comput Graph ; 16(5): 854-69, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20616399

RESUMO

Physics-based particle systems are an effective tool for shape modeling. Also, there has been much interest in the study of shape modeling using deformable contour approaches. In this paper, we describe a new deformable model with electric flows based upon computer simulations of a number of charged particles embedded in an electrostatic system. Making use of optimized numerical techniques, the electric potential associated with the electric field in the simulated system is rapidly calculated using the finite-size particle (FSP) method. The simulation of deformation evolves based upon the vector sum of two interacting forces: one from the electric fields and the other from the image gradients. Inspired by the concept of the signed distance function associated with the entropy condition in the level set framework, we efficiently handle topological changes at the interface. In addition to automatic splitting and merging, the evolving contours enable simultaneous detection of various objects with varying intensity gradients at both interior and exterior boundaries. This electric flows approach for shape modeling allows one to connect electric properties in electrostatic equilibrium and classical active contours based upon the theory of curve evolution. Our active contours can be applied to model arbitrarily complicated objects including shapes with sharp corners and cusps, and to situations where no a priori knowledge about the object's topology and geometry is made. We demonstrate the capabilities of this new algorithm in recovering a wide variety of structures on simulated and real images in both 2D and 3D.

5.
Neuroimage ; 47(1): 122-35, 2009 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-19345740

RESUMO

Characterizing the performance of segmentation algorithms in brain images has been a persistent challenge due to the complexity of neuroanatomical structures, the quality of imagery and the requirement of accurate segmentation. There has been much interest in using the Jaccard and Dice similarity coefficients associated with Sensitivity and Specificity for evaluating the performance of segmentation algorithms. This paper addresses the essential characteristics of the fundamental performance measure coefficients adopted in evaluation frameworks. While exploring the properties of the Jaccard, Dice and Specificity coefficients, we propose new measure coefficients Conformity and Sensibility for evaluating image segmentation techniques. It is indicated that Conformity is more sensitive and rigorous than Jaccard and Dice in that it has better discrimination capabilities in detecting small variations in segmented images. Comparing to Specificity, Sensibility provides consistent and reliable evaluation scores without the incorporation of image background properties. The merits of the proposed coefficients are illustrated by extracting neuroanatomical structures in a wide variety of brain images using various segmentation techniques.


Assuntos
Algoritmos , Encéfalo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Humanos , Sensibilidade e Especificidade
6.
J Trauma ; 65(6): 1478-85; discussion 1485-7, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19077646

RESUMO

BACKGROUND: Data from our previous studies indicate that Taser X26 stun devices can acutely alter cardiac function in swine. We hypothesized that most transcardiac discharge vectors would capture ventricular rhythm, but that other vectors, not traversing the heart, would fail to capture the ventricular rhythm. METHODS: Using an Institutional Animal Care and Use Committee (IACUC) approved protocol, four Yorkshire pigs (25-36 kg) were anesthetized, paralyzed with succinylcholine (2 mg/kg), and then exposed to 10 second discharges from a police-issue Taser X26. For most discharges, the barbed darts were pushed manually into the skin to their full depth (12 mm) and were arranged in either transcardiac (such that a straight line connecting the darts would cross the region of the heart) or non-transcardiac vectors. A total of 11 different vectors and 22 discharge conditions were studied. For each vector, by simply rotating the cartridge 180-degrees in the gun, the primary current-emitting dart was changed and the direction of current flow during the discharge was reversed without physically moving the darts. Echocardiography and electrocardiograms (ECGs) were performed before, during, and after all discharges. p values < 0.05 were considered significant. RESULTS: ECGs were unreadable during the discharges because of electrical interference, but echocardiography images clearly demonstrated that ventricular rhythm was captured immediately in 52.5% (31 of 59) of the discharges on the ventral surface of the animal. In each of these cases, capture of the ventricular rhythm with rapid ventricular contractions consistent with ventricular tachycardia (VT) or flutter was seen throughout the discharge. A total of 27 discharges were administered with transcardiac vectors and ventricular capture occurred in 23 of these discharges (85.2% capture rate). A total of 32 non-transcardiac discharges were administered ventrally and capture was seen in only eight of these (25% capture rate). Ventricular fibrillation (VF) was seen with two vectors, both of which were transcardiac. In the remaining animals, VT occurred postdischarge until sinus rhythm was regained spontaneously. CONCLUSIONS: For most transcardiac vectors, Taser X26 caused immediate ventricular rhythm capture. This usually reverted spontaneously to sinus rhythm but potentially fatal VF was seen with two vectors. For some non-transcardiac vectors, capture was also seen but with a significantly (p < 0.0001) decreased incidence.


Assuntos
Ecocardiografia , Traumatismos por Eletricidade/fisiopatologia , Eletrocardiografia , Traumatismos Cardíacos/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/fisiopatologia , Armas , Animais , Morte Súbita Cardíaca/etiologia , Traumatismos por Eletricidade/diagnóstico por imagem , Traumatismos Cardíacos/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Suínos , Taquicardia Ventricular/diagnóstico por imagem , Fibrilação Ventricular/diagnóstico por imagem
7.
Comput Med Imaging Graph ; 32(1): 22-35, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17933492

RESUMO

A new deformable model, the charged fluid model (CFM), that uses the simulation of charged elements was used to segment medical images. Poisson's equation was used to guide the evolution of the CFM in two steps. In the first step, the elements of the charged fluid were distributed along the propagating interface until electrostatic equilibrium was achieved. In the second step, the propagating front of the charged fluid was deformed in response to the image gradient. The CFM provided sub-pixel precision, required only one parameter setting, and required no prior knowledge of the anatomy of the segmented object. The characteristics of the CFM were compared to existing deformable models using CT and MR images. The results indicate that the CFM is a promising approach for the segmentation of anatomic structures in a wide variety of medical images across different modalities.


Assuntos
Imageamento Tridimensional/métodos , Modelos Biológicos , Anatomia Transversal , Animais , Vasos Sanguíneos/anatomia & histologia , Encéfalo/anatomia & histologia , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética , Reconhecimento Automatizado de Padrão/métodos , Reologia , Eletricidade Estática
8.
Mil Med ; 173(2): 167-73, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18333493

RESUMO

OBJECTIVE: Electromuscular incapacitation (EMI) devices are being used and evaluated by both military and law enforcement agencies. Although the gross muscular response is obvious, physiological responses to these devices are poorly understood. We hypothesized that the intense, repetitive, muscle contractions evoked by EMI devices would cause dose-dependent metabolic acidosis, accompanied by neuromuscular or cardiac injury. METHODS: Using an approved protocol, 26 Yucatan mini-pigs (22 experimental animals and 4 control animals) were anesthetized with ketamine and xylazine. Experimental animals were exposed to MK63 (Aegis Industries, Bellevue, Idaho) discharges over the left anterior hind limb for 10, 20, 40, or 80 seconds. Electrocardiograms, electromyograms, troponin I levels, blood gas values, and electrolyte levels were recorded before and 5, 15, 30, and 60 minutes and 24, 48, and 72 hours after discharge. Skin, muscle, and nerve biopsies were taken from the shocked and contralateral sides. RESULTS: Core body temperature significantly decreased (1.0-1.5 degrees C) in all shocked animals but not in sham-treated control animals. No cardiac dysrhythmias or deaths were seen, and heart rate was unaffected. No clinically significant changes were seen in troponin I, myoglobin, or creatine kinase-MB levels. Central venous blood pH decreased, whereas carbon dioxide pressure and lactate levels increased for 60 minutes after discharge. All values returned to normal by 24 hours after discharge, and no significant histological or electromyographic changes were found. CONCLUSIONS: Changes in blood chemistry were observed but were of little clinical significance, and no neuromuscular damage was detected. Therefore, within the limitations of this model, it appears that EMI can safely be achieved by using this device, even for lengthy periods, without causing significant injury.


Assuntos
Eletrochoque/efeitos adversos , Eletrochoque/instrumentação , Músculo Esquelético/inervação , Porco Miniatura , Acidose/etiologia , Animais , Traumatismos Cardíacos/etiologia , Modelos Animais , Monitorização Fisiológica/métodos , Músculo Esquelético/fisiopatologia , Suínos
9.
J Neurosurg ; 106(6): 1051-60, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17564178

RESUMO

OBJECT: Due to the difficulty of obtaining patient-specific velocity measurements during imaging, many assumptions have to be made while imposing inflow boundary conditions in numerical simulations conducted using patient-specific, imaging-based cerebral aneurysm models. These assumptions can introduce errors, resulting in lack of agreement between the computed flow fields and the true blood flow in the patient. The purpose of this study is to evaluate the effect of the assumptions made while imposing inflow boundary conditions on aneurysmal hemodynamics. METHODS: A patient-based anterior communicating artery aneurysm model was selected for this study. The effects of various inflow parameters on numerical simulations conducted using this model were then investigated by varying these parameters over ranges reported in the literature. Specifically, we investigated the effects of heart and blood flow rates as well as the distribution of flow rates in the A1 segments of the anterior cerebral artery. The simulations revealed that the shear stress distributions on the aneurysm surface were largely unaffected by changes in heart rate except at locations where the shear stress magnitudes were small. On the other hand, the shear stress distributions were found to be sensitive to the ratio of the flow rates in the feeding arteries as well as to variations in the blood flow rate. CONCLUSIONS: Measurement of the blood flow rate as well as the distribution of the flow rates in the patient's feeding arteries may be needed for numerical simulations to accurately reproduce the intraaneurysmal hemodynamics in a specific aneurysm in the clinical setting.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Aneurisma Intracraniano/fisiopatologia , Algoritmos , Pressão Sanguínea/fisiologia , Angiografia Cerebral , Artérias Cerebrais/fisiopatologia , Análise de Elementos Finitos , Frequência Cardíaca/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Reologia , Tomografia Computadorizada por Raios X
10.
IEEE Trans Biomed Eng ; 54(10): 1798-813, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17926678

RESUMO

In this paper, we developed a new deformable model, the charged fluid model (CFM), that uses the simulation of a charged fluid to segment anatomic structures in magnetic resonance (MR) images of the brain. Conceptually, the charged fluid behaves like a liquid such that it flows through and around different obstacles. The simulation evolves in two steps governed by Poisson's equation. The first step distributes the elements of the charged fluid within the propagating interface until an electrostatic equilibrium is achieved. The second step advances the propagating front of the charged fluid such that it deforms into a new shape in response to the image gradient. This approach required no prior knowledge of anatomic structures, required the use of only one parameter, and provided subpixel precision in the region of interest. We demonstrated the performance of this new algorithm in the segmentation of anatomic structures on simulated and real brain MR images of different subjects. The CFM was compared to the level-set-based methods [Caselles et al. (1993) and Malladi et al (1995)] in segmenting difficult objects in a variety of brain MR images. The experimental results in different types of MR images indicate that the CFM algorithm achieves good segmentation results and is of potential value in brain image processing applications.


Assuntos
Neoplasias Encefálicas/diagnóstico , Encéfalo/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Neurológicos , Reologia/métodos , Simulação por Computador , Humanos , Eletricidade Estática
11.
J Trauma ; 63(3): 581-90, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18073604

RESUMO

BACKGROUND: Very little objective laboratory data are available describing the physiologic effects of stun guns or electromuscular incapacitation devices (EIDs). Unfortunately, there have been several hundred in-custody deaths, which have been temporally associated with the deployment of these devices. Most of the deaths have been attributed to specific cardiac and metabolic effects. We hypothesized that prolonged EID exposure in a model animal system would induce clinically significant metabolic acidosis and cardiovascular disturbances. METHODS: Using an Institutional Animal Care and Use Committee-approved protocol, 11 standard pigs (6 experimentals and 5 sham controls) were anesthetized with ketamine and xylazine. The experimentals were exposed to two 40-second discharges from an EID (TASER X26, TASER Intl., Scottsdale, AZ) across the torso. Electrocardiograms, blood pressure, troponin I, blood gases, and electrolyte levels were obtained pre-exposure and at 5, 15, 30, and 60 minutes and 24, 48, and 72 hours postdischarge. p values <0.05 were considered significant. RESULTS: Two deaths were observed immediately after TASER exposure from acute onset ventricular fibrillation (VF). In surviving animals, heart rate was significantly increased and significant hypotension was noted. Acid-base status was dramatically affected by the TASER discharge at the 5-minute time point and throughout the 60-minute monitoring period. Five minutes postdischarge, central venous blood pH (6.86 +/- 0.07) decreased from baseline (7.45 +/- 0.02; p = 0.0004). Pco2 (94.5 mm Hg +/- 14.8 mm Hg) was significantly increased from baseline (45.3 mm Hg +/- 2.6 mm Hg) and bicarbonate levels significantly decreased (15.7 mmol/L +/- 1.04 mmol/L) from baseline (30.4 mmol/L +/- 0.7 mmol/L). A large, significant increase in lactate occurred postdischarge (22.1 mmol/L +/- 1.5 mmol/L) from baseline (1.5 mmol/L +/- 0.3 mmol/L). All values returned to normal by 24 hours postdischarge in surviving animals. A minor, nonsignificant increase in troponin I was seen at 24 hours postdischarge (0.052 ng/mL +/- 0.030 ng/mL, mean +/- SEM). CONCLUSIONS: Immediately after the discharge, two deaths occurred because of ventricular fibrillation. In this model of prolonged EID exposure, clinically significant acid-base and cardiovascular disturbances were clearly seen. The severe metabolic and respiratory acidosis seen here suggests the involvement of a primary cardiovascular mechanism.


Assuntos
Arritmias Cardíacas/etiologia , Eletrochoque/efeitos adversos , Eletrochoque/instrumentação , Equilíbrio Ácido-Base , Análise de Variância , Animais , Arritmias Cardíacas/fisiopatologia , Gasometria , Determinação da Pressão Arterial , Creatina Quinase Forma MB/sangue , Ecocardiografia , Eletrocardiografia , Eletrólitos/análise , Frequência Cardíaca/fisiologia , Modelos Lineares , Mioglobina/sangue , Suínos , Toracotomia , Troponina I/sangue
12.
J Clin Oncol ; 23(34): 8835-44, 2005 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-16314644

RESUMO

PURPOSE: To evaluate the safety of sequentially administered recombinant (r) human (h) interleukin-12 (IL-12) and interferon alfa-2b (IFN-alpha-2b) in patients with advanced cancer and to determine the effects of endogenously produced IFN-gamma on Janus kinase-signal transducer and activator of transcription (Jak-STAT) signal transduction in patient peripheral-blood mononuclear cells (PBMCs). PATIENTS AND METHODS: Forty-nine patients with metastatic cancer received rhIL-12 on day 1 and IFN-alpha-2b on days 2 to 6 of either a 14-day (n = 43) or a 7-day treatment cycle (n = 6). rhIL-12 was initially administered subcutaneously at a dose of 100 ng/kg, whereas IFN-alpha-2b was escalated from 1 to 10 million units (MU) in cohorts of three patients (1, 3, 5, 7, or 10 MU). rhIL-12 was subsequently administered intravenously (IV) in escalating doses (100 to 500 ng/kg) to achieve greater IFN-gamma production. Peripheral blood was drawn for measurement of plasma IFN-gamma and the induction of Jak-STAT signal transduction in PBMCs. RESULTS: No IL-12-or IFN-alpha-related dose-limiting toxicities were observed. There were no responses in 41 assessable patients. Five patients exhibited stable disease lasting 6 months or longer while on therapy. Optimal induction of IFN-gamma by IL-12 occurred after an IV dose of 250 ng/kg. Patient PBMCs exhibited increased levels of STAT1 after IL-12 administration. The peak level of IFN-gamma achieved with IL-12 therapy correlated with the peak level of intracellular STAT1 in patient PBMCs (r = 0.38, P = .021). CONCLUSION: The combination of rhIL-12 and IFN-alpha-2b can be administered sequentially with minimal toxicity. IV administration of rhIL-12 modulates IFN-alpha-induced Jak-STAT signal transduction in patient PBMCs.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/administração & dosagem , Antineoplásicos/efeitos adversos , Relação Dose-Resposta a Droga , Humanos , Interferon alfa-2 , Interferon-alfa/administração & dosagem , Interferon-alfa/efeitos adversos , Interferon gama/sangue , Interleucina-12/administração & dosagem , Interleucina-12/efeitos adversos , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/metabolismo , Pessoa de Meia-Idade , Neoplasias/sangue , Neoplasias/fisiopatologia , Proteínas Recombinantes , Fator de Transcrição STAT1/sangue , Transdução de Sinais/efeitos dos fármacos , Fatores de Tempo , Resultado do Tratamento
13.
Neuroimage ; 40(3): 1003-15, 2008 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18280181

RESUMO

Understanding the variability of the hippocampus in human brain research is essential. The effect of age on the hippocampus has been explored in several studies that have been focused on either normal aging or neural degeneration. Shape analysis of magnetic resonance imaging (MRI) provides morphological measures for brain structures. This study further investigates the age effects on hippocampal morphology in three groups (104 normal controls, 24 Alzheimer's disease (AD) and 14 vascular dementia (VaD) patients). By utilizing a parametric shape analysis of hippocampal MRI scans, each individual distance map is generated and analyzed statistically. Specifically, after eliminating similarity parameters (rotation, translation, and scaling) effects for each hippocampus, an individual distance map is generated from parametric hippocampal surfaces and medial axes. Then statistical methods, including regression, and permutation tests, are applied to detect the differences in hippocampal distance maps and volumes under the effect of age in each group. Statistical analyses reveal that the loss of hippocampal volume and changes in shape are more significantly related to aging in the control group than in AD/VaD. The results also show that the asymmetry of hippocampus in healthy subjects is greater than that in either of the disease groups. Our study shows that 3D statistical shape analysis could enhance the understanding of age effects on local areas of hippocampi. However, the sample sizes of disease groups are relatively low; further studies with more AD/VaD data are needed.


Assuntos
Envelhecimento/fisiologia , Demência Vascular/patologia , Hipocampo/anatomia & histologia , Hipocampo/crescimento & desenvolvimento , Idoso , Algoritmos , Doença de Alzheimer/patologia , Encéfalo/anatomia & histologia , Hipocampo/patologia , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos
14.
Acad Emerg Med ; 15(1): 66-73, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18211316

RESUMO

OBJECTIVES: Data from the authors and others suggest that TASER X26 stun devices can acutely alter cardiac function in swine. The authors hypothesized that TASER discharges degrade cardiac performance through a mechanism not involving concurrent acidosis. METHODS: Using an Institutional Animal Care and Use Committee (IACUC)-approved protocol, Yorkshire pigs (25-71 kg) were anesthetized, paralyzed with succinylcholine (SCh; 2 mg/kg), and then exposed to two 40-second discharges from a TASER X26 with a transcardiac vector. Vital signs, blood chemistry, and electrolyte levels were obtained before exposure and periodically for 48 hours postdischarge. Electrocardiograms and echocardiography (echo) were performed before, during, and after the discharges. p-Values < 0.05 were considered significant. RESULTS: Electrocardiograms were unreadable during the discharges due to electrical interference, but echo images showed unmistakably that cardiac rhythm was captured immediately at a rate of 301 +/- 18 beats/min (n = 8) in all animals tested. Capture continued for the duration of the discharge and in one animal degenerated into fatal ventricular fibrillation (VF). In the remaining animals, ventricular tachycardia (VT) occurred postdischarge for 1-17 seconds, whereupon sinus rhythm was regained spontaneously. Blood chemistry values and vital signs were minimally altered postdischarge and no significant acidosis was seen. CONCLUSIONS: Extreme acid-base disturbances usually seen after lengthy TASER discharges were absent with SCh, but TASER X26 discharges immediately and invariably produced myocardial capture. This usually reverted spontaneously to sinus rhythm postdischarge, but fatal VF was seen in one animal. Thus, in the absence of systemic acidosis, lengthy transcardiac TASER X26 discharges (2 x 40 seconds) captured myocardial rhythm, potentially resulting in VT or VF in swine.


Assuntos
Arritmias Cardíacas/etiologia , Traumatismos por Eletricidade/complicações , Disfunção Ventricular/etiologia , Animais , Arritmias Cardíacas/sangue , Arritmias Cardíacas/diagnóstico , Pressão Sanguínea , Modelos Animais de Doenças , Armas de Fogo , Frequência Cardíaca , Masculino , Valores de Referência , Volume Sistólico , Suínos , Disfunção Ventricular/sangue , Disfunção Ventricular/diagnóstico
15.
J Trauma ; 62(5): 1134-42, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17495713

RESUMO

BACKGROUND: Little objective laboratory data are available describing the physiologic effects of stun guns or electromuscular incapacitation (EMI) devices, but increasing morbidity and even deaths are associated with their use. We hypothesized that exposure to EMI discharges in a model animal system would induce clinically significant acidosis and cardiac arrhythmia. METHODS: Ten Yucatan mini-pigs, six experimental and four sham controls, were anesthetized with ketamine, xylazine, and glycopyrrolate. Experimental pigs were exposed to two 40-second discharges from an EMI device over the left thorax. Electrocardiograms, troponin I, blood gases, and lactate levels were obtained pre-exposure, at 5, 15, 30, 60 minutes, and at 24, 48, and 72 hours postdischarge. RESULTS: No acute or delayed cardiac arrhythmias were seen. Heart rate was not affected significantly (p>0.05). A subclinical increase in troponin I was seen at 24 hours postdischarge (0.040+/-0.030 ng/mL, p>0.05). Central venous blood pH (7.432+/-0.014) and pCO2 (36.1+/-0.9 mm Hg) were not changed significantly (p>0.05) during the 60-minute postdischarge period. A moderate significant increase in lactate occurred in the 5-minute postdischarge group (4.9+/-0.3 mmol/L, p=0.0179). All blood chemistry and vital signs were normal at 24, 48, and 72 hours postdischarge. CONCLUSIONS: Although significant changes in some parameters were seen, these changes were small and of little clinical significance. Lengthy EMI exposures did not cause extreme acidosis or cardiac arrhythmias. These findings may differ from those seen with other EMI devices because of the unique MK63 waveform characteristics or to specific characteristics of the model systems.


Assuntos
Equilíbrio Ácido-Base/fisiologia , Pressão Sanguínea/fisiologia , Estimulação Elétrica/instrumentação , Frequência Cardíaca/fisiologia , Equilíbrio Hidroeletrolítico/fisiologia , Animais , Estimulação Elétrica/efeitos adversos , Desenho de Equipamento , Suínos , Porco Miniatura
16.
J Surg Res ; 143(1): 78-87, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17950076

RESUMO

BACKGROUND: Stun guns or electromuscular incapacitation devices (EMIs) generate between 25,000 and 250,000 V and can be discharged continuously for as long as 5 to 10 min. In the United States, over 200,000 individuals have been exposed to discharges from the most common type of device used. EMI devices are being used increasingly despite a lack of objective laboratory data describing the physiological effects and safety of these devices. An increasing amount of morbidity, and even death, is associated with EMI device use. To examine this type of electrical injury, we hypothesized that EMI discharges will induce acute or delayed cardiac arrhythmia and neuromuscular injury in an animal model. METHODS: Using an IACUC approved protocol, from May 2005 through June 2006 in a teaching hospital research setting, 30 Yucatan mini-pigs (24 experimentals and 6 sham controls) were deeply anesthetized with ketamine and xylazine without paralytics. Experimentals were exposed to discharges from an EID (MK63; Aegis Industries, Bellevue, ID) over the femoral nerve on the anterior left hind limb for an 80 s exposure delivered as two 40 s discharges. EKGs, EMGs, troponin I, CK-MB, potassium, and myoglobin levels were obtained pre-discharge and post-discharge at 5, 15, 30, and 60 min, 24, 48, and 72 h (n = 6 animals) and 5, 15, and 30 d post-discharge (n = 6 animals at each time point). Skin, skeletal muscle, and peripheral nerve biopsies were studied bilaterally. Data were compared using one-way analysis of variance and paired t-tests. P-values <0.05 were considered significant. RESULTS: No cardiac arrhythmias or sudden deaths were seen in any animals at any time point. No evidence of skeletal muscle damage was detected. No significant changes were seen in troponin I, myoglobin, CK-MB, potassium, or creatinine levels. There were no significant changes in compound muscle action potentials (CMAP). No evidence of conduction block, conduction slowing, or axonal loss were detected on EMG. M-wave latency (M(lat), ms), amplitude (M(amp), mV), area (M(area), mV-ms), and duration (M(dur), ms) were not significantly affected by MK63 discharge compared with contralateral or sham controls. F-wave latency (F(lat), ms), a sensitive indicator of retrograde nerve conduction and function, was not significantly affected by MK63 discharge compared with contralateral or sham controls. No significant histological changes were seen at any time point in skeletal muscle or peripheral nerve biopsies although mild skin inflammation was evident. CONCLUSIONS: There was no evidence of acute arrhythmia from MK63 discharges. No clinically significant changes were seen in any of the physiological parameters measured here at any time point. Neuromuscular function was not significantly altered by the MK63 discharge. In this animal model, even lengthy MK63 discharges did not induce muscle or nerve injury as seen using EMG, blood chemistry, or histology.


Assuntos
Eletrochoque/efeitos adversos , Músculo Esquelético/inervação , Músculo Esquelético/fisiopatologia , Animais , Arritmias Cardíacas/etiologia , Biópsia , Creatina Quinase Forma MB/metabolismo , Eletromiografia , Frequência Cardíaca/fisiologia , Modelos Animais , Músculo Esquelético/patologia , Mioglobina/sangue , Nervos Periféricos/patologia , Potássio/metabolismo , Pele/patologia , Suínos , Porco Miniatura , Armas
17.
Neuroimage ; 32(1): 79-92, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16697666

RESUMO

The segmentation of brain tissue from nonbrain tissue in magnetic resonance (MR) images, commonly referred to as skull stripping, is an important image processing step in many neuroimage studies. A new mathematical algorithm, a model-based level set (MLS), was developed for controlling the evolution of the zero level curve that is implicitly embedded in the level set function. The evolution of the curve was controlled using two terms in the level set equation, whose values represented the forces that determined the speed of the evolving curve. The first force was derived from the mean curvature of the curve, and the second was designed to model the intensity characteristics of the cortex in MR images. The combination of these forces in a level set framework pushed or pulled the curve toward the brain surface. Quantitative evaluation of the MLS algorithm was performed by comparing the results of the MLS algorithm to those obtained using expert segmentation in 29 sets of pediatric brain MR images and 20 sets of young adult MR images. Another 48 sets of elderly adult MR images were used for qualitatively evaluating the algorithm. The MLS algorithm was also compared to two existing methods, the brain extraction tool (BET) and the brain surface extractor (BSE), using the data from the Internet brain segmentation repository (IBSR). The MLS algorithm provides robust skull-stripping results, making it a promising tool for use in large, multi-institutional, population-based neuroimaging studies.


Assuntos
Encéfalo/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Crânio/anatomia & histologia , Idoso , Algoritmos , Automação , Humanos , Processamento de Imagem Assistida por Computador , Modelos Neurológicos
18.
Telemed J E Health ; 12(1): 50-7, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16478413

RESUMO

The purpose was to design and implement a Web-based telemedicine system for diabetic retinopathy screening using digital fundus cameras and to make the software publicly available through Open Source release. The process of retinal imaging and case reviewing was modeled to optimize workflow and implement use of computer system. The Web-based system was built on Java Servlet and Java Server Pages (JSP) technologies. Apache Tomcat was chosen as the JSP engine, while MySQL was used as the main database and Laboratory of Neuro Imaging (LONI) Image Storage Architecture, from the LONI-UCLA, as the platform for image storage. For security, all data transmissions were carried over encrypted Internet connections such as Secure Socket Layer (SSL) and HyperText Transfer Protocol over SSL (HTTPS). User logins were required and access to patient data was logged for auditing. The system was deployed at Hubert H. Humphrey Comprehensive Health Center and Martin Luther King/Drew Medical Center of Los Angeles County Department of Health Services. Within 4 months, 1500 images of more than 650 patients were taken at Humphrey's Eye Clinic and successfully transferred to King/Drew's Department of Ophthalmology. This study demonstrates an effective architecture for remote diabetic retinopathy screening.


Assuntos
Retinopatia Diabética/diagnóstico , Angiofluoresceinografia/instrumentação , Internet , Telemedicina/instrumentação , Humanos , Design de Software
19.
Hum Mol Genet ; 15(12): 2025-9, 2006 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-16687438

RESUMO

Normal human brain volume is heritable. The genes responsible for variation in brain volume are not known. Microcephalin (MCPH1) and ASPM (abnormal spindle-like microcephaly associated) have been proposed as candidate genes as mutations in both genes are associated with microcephaly, and common variants of each gene are apparently under strong positive selective pressure. In 120 normal subjects, we genotyped these variants and measured brain volumes using magnetic resonance imaging. We found no evidence that the selected alleles were associated with increases or decreases in brain volume. This result suggests that the selective pressure on these genes may be related to subtle neurobiological effects or to their expression outside the brain.


Assuntos
Encéfalo/anatomia & histologia , Proteínas do Tecido Nervoso/genética , Adolescente , Adulto , Proteínas de Ciclo Celular , Proteínas do Citoesqueleto , Genótipo , Humanos , Imageamento por Ressonância Magnética , Microcefalia/genética , Tamanho do Órgão , Reação em Cadeia da Polimerase , Polimorfismo de Nucleotídeo Único
20.
J Digit Imaging ; 19(2): 148-58, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16598642

RESUMO

Over the past decade, the use of informatics to solve complex neuroscientific problems has increased dramatically. Many of these research endeavors involve examining large amounts of imaging, behavioral, genetic, neurobiological, and neuropsychiatric data. Superimposing, processing, visualizing, or interpreting such a complex cohort of datasets frequently becomes a challenge. We developed a new software environment that allows investigators to integrate multimodal imaging data, hierarchical brain ontology systems, on-line genetic and phylogenic databases, and 3D virtual data reconstruction models. The Laboratory of Neuro Imaging visualization environment (LONI Viz) consists of the following components: a sectional viewer for imaging data, an interactive 3D display for surface and volume rendering of imaging data, a brain ontology viewer, and an external database query system. The synchronization of all components according to stereotaxic coordinates, region name, hierarchical ontology, and genetic labels is achieved via a comprehensive BrainMapper functionality, which directly maps between position, structure name, database, and functional connectivity information. This environment is freely available, portable, and extensible, and may prove very useful for neurobiologists, neurogenetisists, brain mappers, and for other clinical, pedagogical, and research endeavors.


Assuntos
Mapeamento Encefálico , Diagnóstico por Imagem , Processamento de Imagem Assistida por Computador/métodos , Neurobiologia/instrumentação , Software , Interpretação Estatística de Dados , Bases de Dados Factuais , Humanos , Imageamento Tridimensional , Redes Locais , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA