Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(3): 494-502, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36473060

RESUMO

OBJECTIVES: Circulating calprotectin (cCLP) has been shown to be a promising prognostic marker for COVID-19 severity. We aimed to investigate the prognostic value of serial measurements of cCLP in COVID-19 patients admitted to an intensive care unit (ICU). METHODS: From November 2020 to May 2021, patients with COVID-19, admitted at the ICU of the OLV Hospital, Aalst, Belgium, were prospectively included. For sixty-six (66) patients, blood samples were collected at admission and subsequently every 48 h during ICU stay. On every sample (total n=301), a cCLP (EliA™ Calprotectin 2, Phadia 200, Thermo Fisher Scientific; serum/plasma protocol (for Research Use Only, -RUO-) and C-reactive protein (CRP; cobas c501/c503, Roche Diagnostics) analysis were performed. Linear mixed models were used to associate biomarkers levels with mortality, need for mechanical ventilation, length of stay at ICU (LOS-ICU) and medication use (antibiotics, corticosteroids, antiviral and immune suppressant/modulatory drugs). RESULTS: Longitudinally higher levels of all biomarkers were associated with LOS-ICU and with the need for mechanical ventilation. Medication use and LOS-ICU were not associated with variations in cCLP and CRP levels. cCLP levels increased significantly during ICU hospitalization in the deceased group (n=21/66) but decreased in the non-deceased group (n=45/66). In contrast, CRP levels decreased non-significantly in both patient groups, although significantly longitudinally higher CRP levels were obtained in the deceased subgroup. CONCLUSIONS: Serial measurements of cCLP provides prognostic information which can be useful to guide clinical management of COVID-19 patients in ICU setting.


Assuntos
COVID-19 , Humanos , Biomarcadores , COVID-19/diagnóstico , Cuidados Críticos/métodos , Unidades de Terapia Intensiva , Prognóstico , Estudos Retrospectivos , Complexo Antígeno L1 Leucocitário
2.
Clin Chem Lab Med ; 61(7): 1199-1208, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36989428

RESUMO

OBJECTIVES: Detection of antinuclear antibodies (ANA) by indirect immunofluorescence assay using HEp-2 cells (HEp-2 IFA) is used to screen for various autoimmune diseases. HEp-2 IFA suffers from variability, which hampers harmonization. METHODS: A questionnaire was developed to collect information on HEp-2 IFA methodology, computer-assisted diagnosis (CAD) systems, training, inter-observer variability, quality assessment, reagent lot change control, and method verification. The questionnaire was distributed to laboratories by Sciensano (Belgium), national EASI groups (Italy, Croatia, Portugal, Estonia, Greece) and ICAP (worldwide). Answers were obtained by 414 laboratories. The results were analysed in the framework of the recent EFLM/EASI/ICAP ANA recommendations (companion paper). RESULTS: Laboratories used either HEp-2, HEp-2000, or HEp-20-10 cells and most laboratories (80%) applied the same screening dilution for children and adults. The conjugate used varied between laboratories [IgG-specific (in 57% of laboratories) vs. polyvalent]. Sixty-nine percent of CAD users reviewed the automatic nuclear pattern and 53% of CAD users did not fully exploit the fluorescence intensity for quality assurance. Internal quality control was performed by 96% of the laboratories, in 52% of the laboratories only with strongly positive samples. Interobserver variation was controlled by 79% of the laboratories. Limited lot-to-lot evaluation was performed by 68% of the laboratories. Method verification was done by 80% of the respondents. CONCLUSIONS: Even though many laboratories embrace high-quality HEp-2 IFA, substantial differences in how HEp-2 IFA is performed and controlled remain. Acting according to the EFLM/EASI/ICAP ANA recommendations can improve the global performance and quality of HEp-2 IFA and nurture harmonization.


Assuntos
Anticorpos Antinucleares , Doenças Autoimunes , Adulto , Criança , Humanos , Anticorpos Antinucleares/análise , Técnica Indireta de Fluorescência para Anticorpo/métodos , Doenças Autoimunes/diagnóstico , Testes Imunológicos , Variações Dependentes do Observador
3.
Clin Chem Lab Med ; 61(7): 1167-1198, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36989417

RESUMO

OBJECTIVES: Antinuclear antibodies (ANA) are important for the diagnosis of various autoimmune diseases. ANA are usually detected by indirect immunofluorescence assay (IFA) using HEp-2 cells (HEp-2 IFA). There are many variables influencing HEp-2 IFA results, such as subjective visual reading, serum screening dilution, substrate manufacturing, microscope components and conjugate. Newer developments on ANA testing that offer novel features adopted by some clinical laboratories include automated computer-assisted diagnosis (CAD) systems and solid phase assays (SPA). METHODS: A group of experts reviewed current literature and established recommendations on methodological aspects of ANA testing. This process was supported by a two round Delphi exercise. International expert groups that participated in this initiative included (i) the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group "Autoimmunity Testing"; (ii) the European Autoimmune Standardization Initiative (EASI); and (iii) the International Consensus on ANA Patterns (ICAP). RESULTS: In total, 35 recommendations/statements related to (i) ANA testing and reporting by HEp-2 IFA; (ii) HEp-2 IFA methodological aspects including substrate/conjugate selection and the application of CAD systems; (iii) quality assurance; (iv) HEp-2 IFA validation/verification approaches and (v) SPA were formulated. Globally, 95% of all submitted scores in the final Delphi round were above 6 (moderately agree, agree or strongly agree) and 85% above 7 (agree and strongly agree), indicating strong international support for the proposed recommendations. CONCLUSIONS: These recommendations are an important step to achieve high quality ANA testing.


Assuntos
Anticorpos Antinucleares , Doenças Autoimunes , Humanos , Doenças Autoimunes/diagnóstico , Técnica Indireta de Fluorescência para Anticorpo/métodos , Padrões de Referência , Linhagem Celular Tumoral
4.
J Clin Monit Comput ; 37(1): 311-317, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35896757

RESUMO

Isocapnic hyperventilation (ICHV) is occasionally used to maintain the end-expired CO2 partial pressure (PETCO2) when the inspired CO2 (PICO2) rises. Whether maintaining PETCO2 with ICHV during an increase of the PICO2 also maintains arterial PCO2 (PaCO2) remains poorly documented. 12 ASA PS I-II subjects undergoing a robot-assisted radical prostatectomy (RARP) (n = 11) or cystectomy (n = 1) under general endotracheal anesthesia with sevoflurane in O2/air (40% inspired O2) were enrolled. PICO2 was sequentially increased from 0 to 0.5, 1.0, 1.5 and 2% by adding CO2 to the inspiratory limb of the circle system, while increasing ventilation to a target PETCO2 of 4.7-4.9% by adjusting respiratory rate during controlled mechanical ventilation. Pa-ETCO2 gradients were determined after a 15 min equilibration period at each PICO2 level and compared using ANOVA. Mean (standard deviation) age, height, and weight were 66 (6) years, 171 (6) cm, and 75 (8) kg, respectively. Capnograms were normal and hemodynamic parameters remained stable. PETCO2 could be maintained within 4.7-4.9% in all subjects at all times except in 1 subject with 1.5% PICO2 and 5 subjects with 2.0% PICO2; data from the one subject in whom both 1.5 and 2.0% PICO2 resulted in PETCO2 > 5.1% were excluded from analysis. Pa-ETCO2 gradients did not change when PICO2 increased. The effect of a modest rise of PICO2 up to 1.5% on PETCO2 during RARP can be readily overcome by increasing ventilation without altering the Pa-ETCO2 gradients. At higher PICO2, airway pressures may become a limiting factor, which requires further study.


Assuntos
Dióxido de Carbono , Hiperventilação , Masculino , Humanos , Idoso , Respiração , Respiração Artificial , Pulmão
5.
Ann Rheum Dis ; 2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35697487

RESUMO

INTRODUCTION: Commercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement. The diagnostic industry has never adopted the International Union of Immunological Societies-Centers for Disease Control and Prevention (IUIS-CDC) ACPA reference standard. Recently, the National Institute for Biological Standards and Control (NIBSC) prepared a new candidate ACPA standard (18/204). We evaluated both reference materials using different commercially available ACPA assays. MATERIALS AND METHODS: This is an international study in which the NIBSC candidate ACPA standard and the IUIS-CDC ACPA reference material were analysed together with 398 diagnostic samples from individuals with rheumatoid arthritis (RA) and in 1073 individuals who did not have RA using nine commercial ACPA assays. RESULTS: For both reference materials and samples from individuals with RA and individuals who did not have RA, there were large differences in quantitative ACPA results between assays. For most assays, values for the IUIS-CDC standard were lower than values for NIBSC 18/204 and the IUIS-CDC/NIBSC ratio was comparable for several, but not all assays. When NIBSC 18/204 was used as a calibrator, an improvement in alignment of ACPA results across several of the evaluated assays was obtained. Moreover, NIBSC 18/204 could align clinical interpretation for some but not all assays. CONCLUSION: Adoption of an international standard for ACPA determination is highly desirable. The candidate NIBSC 18/204 standard improved the standardisation and alignment of most ACPA assays and might therefore be recommended to be used as reference in commercial assays.

6.
Clin Chem Lab Med ; 60(9): 1440-1448, 2022 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-35781357

RESUMO

OBJECTIVES: Serum free light chain (sFLC) measurements have inherent analytical limitations impacting sFLC clinical interpretation. We evaluated analytical and diagnostic performance of three polyclonal sFLC assays on four analytical platforms. METHODS: sFLC concentration was measured using Diazyme FLC assays (Diazyme) on cobas c501/c503 analyzer (Roche); Freelite assays (The Binding Site) on Optilite analyzer (The Binding Site) and cobas c501 analyzer and Sebia FLC ELISA assays (Sebia) on AP22 ELITE analyzer (DAS). Imprecision, linearity, method comparison vs. Freelite/Optilite, antigen excess detection and reference value verification were assessed. Diagnostic performance was compared on 120 serum samples and on follow-up samples of five patients with κ and λ monoclonal gammopathy. RESULTS: Method comparison showed excellent correlation with Freelite/Optilite method for all assays. A large proportional negative bias was shown for both Sebia κ and λ ELISA and a significant positive proportional bias for λ in the low (<10 mg/L) Freelite/cobas c501 method. Clinically relevant underestimation of κ sFLC levels due to antigen excess was shown for 7% of each Diazyme/cobas application and for 11 and 32.1% of λ sFLC assay of respectively Diazyme/cobas and Sebia/AP22. sFLC reference values revealed application specific. Cohen's κ values were (very) good for κ sFLC but only moderate to good for λ sFLC. In 4/10 follow-up patients, significant differences in clinical interpretation between sFLC assays were noticed. CONCLUSIONS: Important analytical limitations remain for all sFLC applications. Differences in reference values and diagnostic performance hamper interchangeability of sFLC assays. Assay specific sFLC decision guidelines are warranted.


Assuntos
Cadeias Leves de Imunoglobulina , Paraproteinemias , Ensaio de Imunoadsorção Enzimática , Humanos , Cadeias kappa de Imunoglobulina , Cadeias lambda de Imunoglobulina , Paraproteinemias/diagnóstico
7.
Clin Chem Lab Med ; 60(10): 1617-1626, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-35790193

RESUMO

OBJECTIVES: Rheumatoid factor (RF) is a well-established marker for the diagnosis and classification of rheumatoid arthritis (RA). Most studies evaluated IgM RF or isotype-nonspecific total RF assays. We evaluated the added value of IgA RF in this context. METHODS: An international sample cohort consisting of samples from 398 RA patients and 1073 controls was tested for IgA RF with 3 commercial assays. For all RA patients and 100 controls essential clinical and serological data for ACR/EULAR classification were available. RESULTS: The sensitivity of IgA RF for diagnosing RA was lower than the sensitivity of IgM RF. Differences in numerical values between IgA RF assays were observed. With all assays, the highest IgA RF values were found in patients with primary Sjögren's syndrome. Double positivity for IgM RF and IgA RF had a higher specificity for RA than either IgM RF or IgA RF. The sensitivity of double positivity was lower than the sensitivity of either IgA RF or IgM RF. Single positivity for IgA RF was at least as prevalent in controls than in RA patients. Adding IgA RF to IgM RF and anti-citrullinated protein antibodies (ACPA) did not affect RA classification. However, combined positivity for IgA RF, IgM RF and IgG ACPA had a higher specificity and lower sensitivity for RA classification than positivity for either of the antibodies. CONCLUSIONS: IgA RF showed a lower sensitivity than IgM RF. Combining IgA RF with IgM RF and ACPA did not improve sensitivity of RA classification. Combined positivity (IgA-RF/IgM-RF/ACPA) increased specificity.


Assuntos
Artrite Reumatoide , Imunoglobulina A , Imunoglobulina M , Fator Reumatoide , Artrite Reumatoide/diagnóstico , Humanos , Imunoglobulina A/química , Imunoglobulina M/química , Peptídeos Cíclicos , Fator Reumatoide/metabolismo , Sensibilidade e Especificidade
8.
Clin Chem Lab Med ; 59(7): 1247-1255, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-33594844

RESUMO

OBJECTIVES: Currently available computer-aided diagnosis (CAD) systems for the detection of anti-nuclear antibodies (ANA) by indirect immunofluorescence (IIF) assay enable a standardized measurement of system-specific fluorescent intensity (FI) measures. We aimed to evaluate an internal quality control (iQC) program that controls the total ANA IIF process in routine practice. METHODS: In addition to the kit iQC materials, supplemental quality indicators were integrated in a total quality assurance (QA) program: patient-derived iQC's samples (negative, 1/160 fine speckled and 1/160 homogeneous), median sample FI per run and percentage of ANA IIF positive samples per run. Analytical rejection criteria were based on the imprecision of the positivity index (PI) measure of the Zenit PRO system (Menarini). Clinical rejection criteria were based on changes in FI that correspond to a change in ANA IIF titer of ≥2. To evaluate the QA program, different artificial errors were introduced during the ANA IIF process. After every run, quality indicators were evaluated and compared to the pre-set target values. RESULTS: Rescanning the ANA IIF slides five times, using an old conjugate and a needle obstruction resulted in analytically and even clinically relevant errors in ANA IIF results. All errors were correctly detected by the different defined quality indicators. Traditional Westgard rules, including analytically (and clinically) defined rejection limits were useful in monitoring quality indicators. CONCLUSIONS: The integration of a total process iQC program in CAD systems, based on the specific FI measurands and performance criteria of the system, adds value to QA.


Assuntos
Anticorpos Antinucleares , Autoimunidade , Testes Diagnósticos de Rotina , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Controle de Qualidade
10.
Clin Chem Lab Med ; 58(1): 40-49, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-31665107

RESUMO

Background There is a need for additional biomarkers to assist in the diagnosis and prognosis of rheumatoid arthritis (RA). The aim of our study was to evaluate the (pre-analytical, analytical and clinical) performance of serum calprotectin as a marker of inflammation in RA. Methods The study population included 463 rheumatologic patients (including 111 RA patients and 352 controls) who for the first time consulted a rheumatologist, 20 healthy controls and 27 patients with an infectious disease. Calprotectin was measured (using four different assays) in serum or in serum and EDTA plasma (healthy controls and infectious disease group). For rheumatologic patients, results for C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), rheumatoid factor (RF) and anti-cyclic citrullinated peptide antibody (ACPA) were available. Results Results for blood calprotectin were assay- and matrix-dependent, with higher values found in serum than in plasma. Serum calprotectin was higher in RA patients than in rheumatologic diseased controls and in healthy controls. Serum calprotectin was lower in RA patients than in patients with an infectious disease. Serum calprotectin was associated with disease activity (DAS score). The area under the curve (AUC) to discriminate RA from controls was 0.756 for CRP, 0.714 for ESR and 0.726-0.783 for calprotectin. Conclusions Our data document that calprotectin measurement is assay- and matrix-dependent. Serum calprotectin is associated with disease activity. Additional (prospective) studies are warranted to further evaluate the prognostic and diagnostic value of blood calprotectin measurements.


Assuntos
Artrite Reumatoide/sangue , Análise Química do Sangue/métodos , Complexo Antígeno L1 Leucocitário/sangue , Adulto , Artefatos , Biomarcadores/sangue , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Masculino
11.
Clin Chem Lab Med ; 57(7): 990-998, 2019 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-30838836

RESUMO

Background The introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis may allow for more harmonized ANA IIF reporting, provided that a thorough quality assurance program controls this process. The aim of this study was to evaluate various quality indicators used for ANA IIF analysis with the final goal of optimizing the iQC program. Methods In an experimental setup, we introduced artificial errors, mimicking plausible problems during routine practice on a QUANTA-Lyser-NOVA View® system (Inova Diagnostics, San Diego, CA, USA). Predetermined quality indicators were evaluated against predefined acceptance criteria. In addition, we retrospectively investigated the applicability of the selected quality indicators in the daily routine practice during three pre-defined periods. Results Both the experimental as the retrospective study revealed that pre-analytical, analytical and post-analytical errors were not highlighted by company internal quality control (iQC) materials. The use of patient derived iQC samples, median fluorescence intensity results per run and the percentage of positive ANA IIF results as additional quality indicators ensured a more adequate ANA IIF quality assurance. Furthermore, negative and moderate positive sample iQC materials merit clinical validation, as titer changes of >1 correspond to clinically important shifts. Traditional Westgard rules, including a clinically defined stop limit, revealed to be useful in monitoring of the supplemental quality indicators. Conclusions A thorough ANA IIF quality assurance for daily routine practice necessitates the addition of supplemental quality indicators in combination with well-defined acceptance criteria.


Assuntos
Anticorpos Antinucleares/análise , Técnica Indireta de Fluorescência para Anticorpo/métodos , Automação , Erros de Diagnóstico , Técnica Indireta de Fluorescência para Anticorpo/normas , Humanos , Controle de Qualidade , Estudos Retrospectivos
13.
Ann Rheum Dis ; 77(5): 667-677, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29363510

RESUMO

OBJECTIVES: Rheumatoid factor (RF) and anti-cyclic citrullinated protein/peptide antibodies (ACPA) are integrated in the 2010 American College of Rheumatology/European League Against Rheumatism (ACR/EULAR) classification criteria for rheumatoid arthritis (RA). The objectives of this study were to evaluate the technical and diagnostic performance of different RF and ACPA assays and to evaluate whether differences in performance impact RA classification. METHODS: Samples from 594 consecutive patients who for the first time consulted a rheumatologist (44 of whom were diagnosed with RA) and 26 extra newly diagnosed patients with RA were analysed with six different RF assays (Menarini, Thermo Fisher, Inova, Roche, Abbott, Euroimmun) and seven different ACPA assays (Menarini, Thermo Fisher, Inova, Roche, Abbott, Euro Diagnostica, Euroimmun). RESULTS: We found differences in analytical performance between assays. There was poor numerical agreement between the different RF and ACPA assays. For all assays, the likelihood ratio for RA increased with increasing antibody levels. The areas under the curve of receiver operating characteristic analysis of the RF (range 0.676-0.709) and ACPA assays (range 0.672-0.769) only differed between some ACPA assays. Nevertheless, using the cut-off proposed by the manufacturer, there was a large variation in sensitivity and specificity between assays (mainly for RF). Consequently, depending on the assay used, a subgroup of patients (13% for RF, 1% for ACPA and 9% for RF/ACPA) might or might not be classified as RA according to the 2010 ACR/EULAR criteria. CONCLUSION: Due to poor harmonisation of RF and ACPA assays and of test result interpretation, RA classification according to 2010 ACR/EULAR criteria may vary when different assays are used.


Assuntos
Anticorpos Antiproteína Citrulinada/sangue , Artrite Reumatoide/diagnóstico , Imunoensaio/métodos , Fator Reumatoide/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Clin Chem Lab Med ; 56(7): 1090-1099, 2018 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-29427547

RESUMO

BACKGROUND: Screening for antinuclear antibodies by indirect immunofluorescence (ANA-IIF) is essential in the diagnostic workup of ANA-associated autoimmune rheumatic diseases (AARDs). However, also healthy individuals may test positive, making the interpretation challenging. Recent reports suggest that dense fine speckled 70 antibodies (anti-DFS70) may facilitate this challenge. Here, we investigate their clinical importance based on data from four Belgian laboratories (one primary, two secondary and one tertiary care). METHODS: At least one specific DFS70 assay (DFS70 IgG ELISA or lineblot [Euroimmun, full length antigen] and/or DFS70 IgG CLIA [Inova Diagnostics, truncated antigen]) was performed on four consecutive cohorts of homogeneous-like ANA-IIF samples (n=697). Co-occurrence with AARD-specific ANA and clinical information were documented in the anti-DFS70-positive samples. RESULTS: Using a combination of solid phase techniques, we found between 7.6% and 26% anti-DFS70 in the different cohorts. Focusing on anti-DFS70 CLIA-positive samples without co-occurrence of AARD-specific ANA, we observed a trend towards lower frequency in tertiary (8% [p=0.0786]) and secondary care (12% [p=0.1275] and 6% [p<0.001]) compared to primary care (21%). Moreover, in this specific subpopulation, AARD was less frequent (0%-50% compared to 6%-77% in the total anti-DFS70-positive group). CONCLUSIONS: Anti-DFS70 prevalence depends on the applied assay and care setting. Our data suggest that, for an ANA-IIF-positive patient, it is rather the absence of AARD-associated ANA and clinical symptoms that contribute to the exclusion of AARD than the presence of anti-DFS70. Nevertheless, isolated anti-DFS70 helps to clarify positive ANA-IIF results, especially if pretest probability for AARD is low.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/imunologia , Anticorpos Antinucleares/sangue , Doenças Autoimunes/diagnóstico , Doenças Reumáticas/diagnóstico , Fatores de Transcrição/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antinucleares/imunologia , Bélgica , Feminino , Técnica Indireta de Fluorescência para Anticorpo/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Clin Chem Lab Med ; 55(10): 1564-1573, 2017 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28222018

RESUMO

BACKGROUND: We evaluated the analytical performance of six different faecal calprotectin immunoassays together with their diagnostic accuracy in the discrimination between functional and organic bowel disorders. METHODS: The faecal samples were obtained from inflammatory bowel disease patients (n=27) at the time of diagnosis [Crohn's disease (n=15), colitis ulcerosa (n=12)], gastroenterologic disease control patients (n=52) and rheumatologic disease control patients (n=26). All individuals included in the study underwent a concurrent ileocolonoscopy. Analytical performance (imprecision, accuracy, carry-over, correlation and agreement) and diagnostic accuracy (sensitivity, specificity, likelihood ratios) of the different assays were evaluated. RESULTS: All methods demonstrated good analytical performance, but within-run and total imprecision varied depending on the assay methodology used. Using Passing Bablok and Bland-Altman analyses, low quantitative agreement was observed between the assays. All assays showed excellent diagnostic accuracy, with areas under the receiver operating characteristic curves (ROC) ranging from 0.974 to 0.998. The AUCs were not significantly different between assays (p>0.05). Diagnostic sensitivity at the cut-off at a fixed specificity of 75% ranged from 95.2% to 100%. Introduction of multiple result intervals increased the clinical interpretation of all the assays. CONCLUSIONS: Analytical and diagnostic performance of the evaluated faecal calprotectin assays is good, but numerical values differ substantially between the assays necessitating the use of different clinical cut-offs. Introduction of multiple result intervals aids in clinical decision-making.


Assuntos
Fezes/química , Imunoensaio , Doenças Inflamatórias Intestinais/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Colonoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Adulto Jovem
20.
Hemoglobin ; 39(6): 435-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26372398

RESUMO

We report the case of a 56-year-old Caucasian woman in whom hemoglobinopathy screening was triggered following an aberrant Hb A1c analysis. Preliminary diagnosis of the hemoglobin (Hb) variant was obtained through cation exchange high performance liquid chromatography (HPLC) and gel electrophoresis. DNA analysis confirmed the presence of Hb J-Amiens [ß17(A14)Lys→Asn; HBB: c.[54G > C or 54G > T)]. However, an unbalanced ratio between wild type and mutant signal after direct sequencing and a lower than expected percentage of this Hb variant led to the suggestion of a mosaic expression. Furthermore, different methods [capillary zone electrophoresis (CZE), cation exchange HPLC and boronate affinity] were tested to study the possible interference of this variant with Hb A1c measurements. These investigations showed a clinically relevant difference between the methods tested. Hb A1c analysis may lead to the discovery of new Hb variants or mosaicism for previously described Hb variants. This may have genetic consequences for the offspring of carriers and brings about the question of partner testing.


Assuntos
Hemoglobinas Glicadas/genética , Hemoglobina J/genética , Hemoglobina J/metabolismo , Fenótipo , Substituição de Aminoácidos , Códon , Análise Mutacional de DNA , Índices de Eritrócitos , Feminino , Expressão Gênica , Genótipo , Hemoglobinas Glicadas/metabolismo , Hemoglobinopatias/diagnóstico , Hemoglobinopatias/genética , Humanos , Pessoa de Meia-Idade , Mutação , Globinas beta/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA