Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int Endod J ; 52(2): 244-249, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30040121

RESUMO

AIM: To determine the distortional angle and torsional load at the pseudoelastic limit of Reciproc Blue instruments and to verify the safety of using pre-set dedicated motors designed for use with the original Reciproc instruments. METHODOLOGY: Two torsional conditions of Reciproc R25 and Reciproc Blue R25 were tested using a custom device. The first condition fixed the file tips at 3 mm and repetitively rotated them, with gradually increasing angles, from 10° to 270°, and the resulting torque was recorded (n = 15). The second test involved a single continuous rotation until fracture (n = 15). The pseudoelastic limits of the instruments were determined from their torque-rotation curves. For statistical analysis, two-way analysis of variance and t-tests were used, at a 95% significance level. Tested specimens were examined using field-emission scanning electron microscopy (FE-SEM). RESULTS: The angle at the pseudoelastic limit was significantly greater for Reciproc Blue than Reciproc, regardless of test mode (P < 0.05). When torsional loading was repeated, using gradually increasing rotational angles, the torsional resistance was significantly lower than for a single rotation (P < 0.05). However, under all test conditions, the pseudoelastic limit was below the pre-set 170° of the dedicated reciprocating motor. FE-SEM evaluation of the lateral aspects of the instruments revealed numerous longitudinal microcracks running along their long axis. For Reciproc Blue groups, the file shaft machining grooves were distorted after repetitive and continuous torsional tests. CONCLUSIONS: The 170° pre-set angle of the dedicated endodontic motors for the Reciproc system was safe for Reciproc Blue in single or time-restricted use.


Assuntos
Instrumentos Odontológicos , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Torção Mecânica , Análise de Variância , Ligas Dentárias/química , Falha de Equipamento , Análise de Falha de Equipamento , Segurança de Equipamentos , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Níquel/química , Rotação , Estresse Mecânico , Propriedades de Superfície , Titânio/química , Torque
2.
Clin Exp Allergy ; 45(2): 347-67, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24766413

RESUMO

Food allergic patients have to deal with an avoidance diet. Confusing labelling terms or precautionary labels can result in misinterpretation and risk-taking behaviour. Even those patients that strictly adhere to their diet experience (sometimes severe) unexpected allergic reactions to food. The frequency, severity and causes of such reactions are unknown. The objective of this review was to describe the frequency, severity and causes of unexpected allergic reactions to food in food allergic patients aged > 12 years, in order to develop improved strategies to deal with their allergy. A systematic review was carried out by two researchers, in six electronic databases (CINAHL, Cochrane, EMBASE, Medline, Psychinfo and Scopus). The search was performed with keywords relating to the frequency, severity and causes of unexpected allergic reactions to food. This resulted in 24 studies which met the inclusion criteria; 18 observational and six qualitative studies. This review shows that knowledge about the frequency of unexpected reactions is limited. Peanut, nuts, egg, fruit/vegetables and milk are the main causal foods. Severe reactions and even fatalities occur. Most reactions take place at home, but a significant number also take place when eating at friends' houses or in restaurants. Labelling issues, but also attitude and risky behaviour of patients can attribute to unexpected reactions. We conclude that prospective studies are needed to get more insight in the frequency, severity, quantity of unintended allergen ingested and causes of unexpected allergic reactions to food, to be able to optimize strategies to support patients in dealing with their food allergy. Although the exact frequency is not known, unexpected reactions to food occur in a significant number of patients and can be severe. For clinical practice, this means that patient education and dietary instructions are necessary.


Assuntos
Alérgenos/imunologia , Hipersensibilidade Alimentar/diagnóstico , Hipersensibilidade Alimentar/etiologia , Alimentos/efeitos adversos , Hipersensibilidade Alimentar/epidemiologia , Humanos , Prevalência , Índice de Gravidade de Doença
3.
Int Endod J ; 48(7): 666-72, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25088359

RESUMO

AIM: To examine the effect of several standard geometric characteristics of rotary instruments on the 'screw-in' forces and stresses generated on root dentine using 3D finite element analysis (FEA). METHODOLOGY: Four cross-sectional designs (triangular, slender-rectangular, rectangular and square) were evaluated. The area of the triangular cross-section and of the slender-rectangular model were the same. Another rectangular model had the same centre-core diameter as the triangular one. Each design was twisted into a file model with 5, 10 or 15 threads over its 16-mm-long working section. Three curved root canals were simulated as rigid surface models: θ = 15 degrees/R = 36 mm radius; θ = 30/R = 18; and θ = 45/R = 12. A commercial FEA package was used to simulate the file rotating in the canal to determine the 'screw-in' force and reaction torque on the instrument. RESULTS: Instruments of a square cross-section had the highest 'screw-in' force and reaction torsional stresses followed by the rectangle, the triangle design and the slender-rectangle design, respectively. The file with closer pitch generated lower stresses, compared with that with longer pitch. The greater the root canal curvature, the higher the 'screw-in' force and reaction torque generated. CONCLUSION: This study demonstrated that the 'screw-in' tendency depends on both the instrument geometry and canal curvature. Clinicians should be aware that certain instrument designs are prone to develop high 'screw-in' forces, requiring the operator to maintain control of the handpiece or to use a brushing action to prevent instruments being pulled into the canal.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Ligas Dentárias , Análise do Estresse Dentário/métodos , Elasticidade , Desenho de Equipamento , Análise de Elementos Finitos , Níquel , Estresse Mecânico , Titânio , Torção Mecânica
4.
Gen Dent ; 62(4): e30-3, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24983182

RESUMO

This in vitro study investigated 4 products (containing calcium, phosphate, and/or fluoride) and their ability to reharden enamel softened by hydrochloric acid as compared to hardening with saliva alone. Extracted human molars were embedded and polished, and baseline Vickers hardness (VH) of enamel was measured. Statistical analysis was performed with ANOVA followed by Student-Newman-Keuls post hoc tests (P = 0.05). For all groups, VH decreased significantly after immersion in hydrochloric acid. Fluoride in combination with casein phosphopeptide amorphous calcium phosphate was the most effective treatment for enamel hardness recovery.


Assuntos
Esmalte Dentário , Ácido Clorídrico/administração & dosagem , Erosão Dentária/terapia , Humanos , Técnicas In Vitro , Erosão Dentária/etiologia
5.
Oper Dent ; 49(4): 475-483, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38987928

RESUMO

OBJECTIVES: Using a wetting resin or adhesive system as an instrument lubricant when placing composite layers is commonly practiced to improve handling. This study investigated whether instrument lubricants affected strength, stiffness, or hardness. METHODS: Composite beams (TPH Spectra) were fabricated using a stainless steel mold (25×2.5×2 mm) in two steps, where the second half (12.5 mm) was added and cured against a cured first half (n=15). The composite surface at the open end of the first half was smoothed using an instrument lubricated with wetting resin (Ultradent) or universal adhesive (ScotchBond Universal), enough to prevent sticking, or without lubrication. An additional beam of each group was characterized using scanning electron microscopy. Monolithic specimens were also fabricated. After 24 hour storage (37°C, 100% humidity), the beams' flexural strength and stiffness were determined by four-point bending. Vickers surface hardness was measured on 24-hour composite samples in 2 mm deep acrylic cavities, cured after the surface was smoothed with the two instrument lubricants or no lubricant (n=10). Hardness was remeasured after finishing with a series of contouring and polishing discs. Data were statistically analyzed using ANOVA followed by Student-Newman-Keuls post hoc test at 0.05 significance level. RESULTS: There were significant differences (p<0.001) in flexural strength and stiffness among groups. While strength and stiffness were not affected by using a wetting resin as instrument lubricant, use of a universal adhesive increased strength and stiffness significantly, achieving monolithic values. Scanning electron micrographs showed less porosities at the interface when using instrument lubricants. Surface hardness was significantly reduced in groups in which instrument lubricants were used, but finishing/polishing restored original hardness (p<0.001). CONCLUSIONS: Lubricating an instrument with a wetting agent did not adversely affect physical or surface properties, provided the surface was finished and polished. If a universal adhesive was used as lubricant, the strength and stiffness of a layered composite could be increased, reaching monolithic values.


Assuntos
Resinas Compostas , Resistência à Flexão , Dureza , Lubrificantes , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Lubrificantes/química , Resinas Compostas/química , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Humanos
6.
Int J Med Inform ; 181: 105296, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37992559

RESUMO

INTRODUCTION: The pressure on general practitioners (GPs) is rising due to the increasing demand for care and a decreasing availability of GPs. eHealth is seen as one of the solutions to enhance accessibility and reduce workload. A platform supporting the organization and communication in general practice has been developed offering services, such as econsultations. This study aims to evaluate healthcare usage and costs of patients using this platform by comparing these outcomes (1) before and after implementation and (2) an intervention with a matched control group. MATERIAL AND METHODS: This study is a retrospective observational cohort study. To evaluate the longitudinal impact of the implementation on healthcare usage, mixed model Poisson analyses were used with time as a factor term for the within-subject analysis and exposure to the platform as a factor term and an interaction term (i.e., exposure X 6-months) in the between-subject analysis. Cost analyses were done with mixed model analyses of variance over time. RESULTS: The total number of GP consultations significantly increased after compared to before implementation (i.e., Rate = 1.52; p < 0.001). The number of GP consultations was higher in the intervention compared to the control group (respectively, Rate = 1.23; p = 0.035). Healthcare costs increased for GP consultations after compared to before implementation (€13,57; p < 0.001). The costs for GP consults were significantly higher in the intervention compared to the control group (€7,06; p 0.018). CONCLUSION: This study showed a rise in GP consultations and costs when implementing a digital platform. This increase was presumably and partly caused by circumstances in one of the two included practices. Moreover, creating new options for contacting and communicating with the GP can enhance care accessibility and thereby driving an increase in consultations. This digital platform is a promising working method in general practice to facilitate patients and provide GPs with more flexibility.


Assuntos
Medicina Geral , Clínicos Gerais , Humanos , Estudos Retrospectivos , Seguradoras , Atenção à Saúde , Custos de Cuidados de Saúde , Comunicação
7.
J Mech Behav Biomed Mater ; 143: 105913, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37257311

RESUMO

Warming composite resin before insertion to reduce viscosity is advocated for improving adaptation and reducing voids. This study evaluated how prewarming altered porosities, adaptation, and strength. Twenty composite restorations were placed in 2 increments in typodont teeth with a large Class II preparation. The composite was either at room temperature (control) or prewarmed to 68 °C (n = 10/group). Each increment was light-cured for 20s. After 24h, the restored teeth were sectioned and imaged under a stereomicroscope. Examiners ranked the quality of adaptation to walls and between increments, and the presence of voids on a 0-3 scale. Results were statistically analyzed using Mann-Whitney U Test. Diametral tensile strength of monolithic or incrementally-filled composite cylinders (6 mm diameter × 4 mm height; n = 10/group) made with room temperature or prewarmed composite were tested at 0.5 mm/min. Strength results were analyzed using ANOVA statistics followed by pairwise comparisons. Restorations made with prewarmed composite had significantly fewer large voids and better adaptation to cavity walls and between layers (P < 0.05). Strength of prewarmed composite was higher than room temperature composite, and was significantly higher in monolithic specimens (P < 0.05). It was concluded that prewarming conventional composite can improve its handling, making it handle more like a flowable composite without jeopardizing physical properties. The prewarmed composite was found to have better adaptation and fewer voids, and attained higher strength than composite that was not prewarmed.


Assuntos
Resinas Compostas , Cimentos de Resina , Porosidade , Estatísticas não Paramétricas , Viscosidade , Restauração Dentária Permanente , Teste de Materiais
8.
Oper Dent ; 48(1): 98-107, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36445972

RESUMO

OBJECTIVES: High-power LED curing lights and bulk-fill resin composites are intended to reduce chair time. This study investigated depth of cure, post-gel shrinkage (responsible for shrinkage stress), and heat generation in bulk-fill composites when cured according to minimum curing times recommended by manufacturers of curing lights and composites. METHODS: A regular LED curing light (Demi Ultra, 1350 mW/cm2, Kerr Dental) and two LED curing lights with high-power modes (VALO Grand, 3117 mW/cm2 Xtra Power, Ultradent; and Bluephase PowerCure, 2435 mW/cm2 Turbo and 3344 mW/cm2 3sCure, Ivoclar Vivadent) were tested on three bulk-fill composites (Filtek One Bulk Fill, 3M Oral Care Solutions; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; Tetric Powerfill, Ivoclar Vivadent). Using minimum times recommended by manufacturers (3, 5, 6, 10, or 20 seconds), depth of cure was determined by Vickers hardness of specimens cured in a slot (n=10). Post-gel polymerization shrinkage was measured using a strain gauge (n=10) and temperature with a thermocouple (n=5). Results were analyzed using two- and one-way analysis of variance (ANOVA) followed by pairwise comparisons or Student-Newman-Keuls post hoc tests (α=0.05). RESULTS: Curing lights and curing protocols significantly affected depth of cure, post-gel shrinkage, and temperature rise (p<0.001). Cure decreased with depth whereby best overall curing performance was achieved by the 20 second exposure at lowest irradiance (Demi Ultra). Fast curing (3-5 seconds) at high irradiance resulted in lesser depth-of-cure performance, except for the BluePhase-Tetric PowerFill combination. Post-gel shrinkage was higher in all composites when cured at high irradiance (p<0.001), while heat generated also tended to be higher. CONCLUSIONS: Although the high-power LED curing lights advertise time savings, not all manufacturer recommended minimum curing times cured bulk-fill materials to the same extent. Moreover, these time savings came at a cost of higher post-gel shrinkage and generated more heat in the bulk-fill composites than the lower irradiance curing protocol.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Humanos , Temperatura , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Resinas Compostas/uso terapêutico , Dureza , Polimerização
9.
Dent Mater ; 38(8): 1404-1418, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35787894

RESUMO

OBJECTIVE: Evaluate the effect of different restorative filling techniques on the residual shrinkage stress (ShrS), cuspal strain (CS), depth of cure (DC), and enamel crack formation (Ec) in molars with MOD restorations. METHODS: Post-gel shrinkage, elastic modulus, compressive and diametral tensile strength of the Filtek One Bulk Fill composite were calculated. Sixty molars with MOD preparations were restored using four filling techniques: Bulk; Horizontal; Oblique; Natural enamel and dentin substitution (NEDS) technique. CS was measured using a strain gauge (n = 10). The DC (n = 5) was measured using Knoop hardness. Shrinkage stress/strain was analyzed using 3D finite element analysis. The Ec analysis was carried out by transillumination. Two-way ANOVA with repeated measures and Tukey's HSD test (α = 0.05) was performed for the CS data. Two-Way ANOVA and Tukey's HSD test was performed for the DC data (α = 0.05). RESULTS: CS was higher at the lingual cusp for the horizontal and NEDS technique. No statistical difference was found between the buccal and lingual CS values for the Bulk (p = 0.367) or Oblique techniques (p = 0.192). CS values were lower for the Bulk. More enamel cracks were found for the Bulk. DC was lower at 4 mm regardless the filling technique. The Horizontal showed the highest ShrS values. The Bulk generated the lower ShrS values. SIGNIFICANCE: A Bulk technique caused the lowest shrinkage stress/strain. An Oblique technique yielded the best balance between stress, strain and crack formation. NEDS technique is a good alternative to decrease the number of increments while maintaining the stress levels nearby the Oblique technique.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Esmalte Dentário , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Teste de Materiais , Dente Molar , Polimerização
10.
Int Endod J ; 44(6): 519-24, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21276019

RESUMO

AIM: To evaluate the effect of taper, specimen supports and the isotropic and orthotropic properties of the posts on flexure and stress response during three-point bending using finite element analysis. METHODOLOGY: A three-dimensional finite element model of a fibre post was created. The occlusal portion was cylindrical whilst the apical portion was tapered. Five different support positions were evaluated during a simulated three-point bending test: M1 - support distance of 10 mm centralized and no tilt; M2 - 10 mm centralized with tilt; M3 - 10 mm not centralized and no tilt; M4 - 10 mm not centralized with tilt; M5 - 6 mm not centralized with no tilt. A sixth post model (M6) was a centralized post without tapered section. The applied properties were elastic and orthotropic. RESULTS: Tilting the tapered posts to level them in the test setup had little effect on the outcome. Flexure increased when 50% of the bent portion involved taper (M1, M2). If only 20% of the bent post involved taper (M3, M4), the flexure values were close to M6 (no taper). The orthotropic properties also caused increased flexure compared to an isotropic post. Maximum stresses were only a little higher when 50% of the bend structure involved taper, whilst the orthotropic properties had little effect. CONCLUSIONS: Regardless of levelling, the flexural stress determination with tapered fibre posts in the three-point bending test was valid as long as the tapered portion was limited in length.


Assuntos
Simulação por Computador , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Análise de Elementos Finitos , Técnica para Retentor Intrarradicular/instrumentação , Fenômenos Biomecânicos , Humanos , Imageamento Tridimensional , Maleabilidade
11.
J Oral Rehabil ; 38(6): 469-74, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20955394

RESUMO

The aetiology of non-carious cervical lesions (NCCLs) is not well understood and still controversial. The aim of this ex-vivo study was to examine the morphological characteristics of NCCLs for clinical evidence of enamel loss above the cemento-enamel junction (CEJ) as suggested by the abfraction theory. Fifty extracted human teeth with various types of NCCLs were collected and scanned by micro computed tomography. The reconstructed three-dimensional models were evaluated from multiple aspects, including longitudinal cross-section series. The location of internal line angle and proximal exits of the lesions were evaluated in relation to the level of CEJ. The coronal margins of the lesions were inspected for evidence of enamel loss above the CEJ using the bucco-lingual longitudinal sectional images. Coronal margins of the lesions were located along and/or under the CEJ for all of the 50 samples. In most of the lesions, regardless of lesion type, the proximal exits and internal line angles were located below the CEJ. This study did not detect clinical evidence of enamel loss above the occlusal margin of NCCLs as would have been expected according to the general abfraction mechanism.


Assuntos
Esmalte Dentário/patologia , Colo do Dente/patologia , Desgaste dos Dentes/patologia , Humanos , Colo do Dente/diagnóstico por imagem , Desgaste dos Dentes/diagnóstico por imagem , Microtomografia por Raio-X
12.
Dent Mater ; 36(5): 681-686, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32238272

RESUMO

OBJECTIVES: Secondary caries can be accelerated by hydrodynamic flow in a gap between the tooth and restorative material. This study investigated whether occlusal loading can lead to increased hydrodynamic flow by deforming a gap between tooth and restorative material. METHODS: 3D finite element analysis was employed to model a molar containing a restoration with an interfacial gap. The model was loaded using direct cusp-to-restoration contact and using a rubber tube model simulating a food bolus. The object exerting pressure was moved across the molar from buccal to lingual side. The applied forces were 50, 100, 200 and 400N. The elastic modulus of the restoration material was varied between 5, 10, 15.9 and 25GPa to resemble different kinds of composite. The primary outcome parameter was the volume of the gap under occlusal pressure. RESULTS: Occlusal loading resulted in deformation of the gap area. Maximum deformation was seen when loading was applied in the middle of the restoration. Higher forces and lower restoration stiffness led to more deformation of the gap. Maximum deformation with a force of 100N and composite modulus of 15.9GPa was -0.0083mm3 (1.12%). SIGNIFICANCE: Deformation of the gap between tooth and restorative material could lead to increased hydrodynamic flow and faster secondary caries lesion formation. The measured deformation is small. Further research needs to show whether gap compression through occlusal loading affects secondary caries formation to a clinically relevant degree.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Materiais Dentários , Análise do Estresse Dentário , Módulo de Elasticidade , Análise de Elementos Finitos
13.
Int Endod J ; 42(7): 593-602, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19467053

RESUMO

AIM: To evaluate how different cross-sectional designs affect stress distribution in nickel-titanium (NiTi) instruments during bending, torsion and simulated shaping of a curved canal. METHODOLOGY: Four NiTi rotary instruments with different cross-sectional geometries were selected: ProFile and HeroShaper systems with a common triangle-based cross section, Mtwo with an S-shaped rectangle-based design and NRT with a modified rectangle-based design. The geometries of the selected files were scanned in a micro-CT and three-dimensional finite-element models were created for each system. Stiffness characteristics for each file system were determined in a series of bending and torsional conditions. Canal shaping was simulated by inserting models of the rotating file into a 45 degrees curved canal model. Stress distribution in the instruments was recorded during simulated shaping. After the instruments were retracted from the canal, residual stresses and permanent bending of their tips due to plastic deformation were determined. RESULTS: The greatest bending and torsional stiffness occurred in the NRT file. During simulated shaping, the instruments with triangle-based cross-sectional geometry had more even stress distributions along their length and had lower stress concentrations than the instruments with rectangle-based cross sections. Higher residual stresses and plastic deformations were found in the Mtwo and NRT with rectangle-based cross-sectional geometries. CONCLUSIONS: Nickel-titanium instruments with rectangle-based cross-sectional designs created higher stress differentials during simulated canal shaping and may encounter higher residual stress and plastic deformation than instruments with triangle-based cross sections.


Assuntos
Ligas Dentárias/química , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Cavidade Pulpar/anatomia & histologia , Módulo de Elasticidade , Desenho de Equipamento , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Teste de Materiais , Maleabilidade , Estresse Mecânico , Propriedades de Superfície , Torção Mecânica , Microtomografia por Raio-X
14.
Oper Dent ; 44(2): E97-E104, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30888925

RESUMO

OBJECTIVES:: This study tested whether delayed photoactivation could reduce shrinkage stresses in dual-cure composites and how it affected the depth-of-cure and mechanical properties. METHODS AND MATERIALS:: Two dual-cure composites (ACTIVA and Bulk EZ) were subjected to two polymerization protocols: photoactivation at 45 seconds (immediate) or 165 seconds (2 minutes delayed) after extrusion. Typodont premolars with standardized preparations were restored with the composites, and cuspal flexure caused by polymerization shrinkage was determined with three-dimensional scanning of the external tooth surfaces before restoration (baseline) and at 10 minutes and one hour after photoactivation. Bond integrity (intact interface) was verified with dye penetration. Depth-of-cure was determined by measuring Vickers hardness through the depth at 1-mm increments. Elastic modulus and maximum stress were determined by four-point bending tests (n=10). Results were analyzed with two- or three-way analysis of variance and pairwise comparisons (Bonferroni; α=0.05). RESULTS:: Delayed photoactivation significantly reduced cuspal flexure for both composites at 10 minutes and one hour ( p≤0.003). Interface was >99% intact in every group. Depth-of-cure, elastic modulus, and flexural strength were not significantly different between the immediate and delayed photoactivation ( p>0.05). The hardness of ACTIVA reduced significantly with depth ( p<0.001), whereas the hardness of Bulk EZ was constant throughout the depth ( p=0.942). CONCLUSIONS:: Delayed photoactivation of dual-cure restorative composites can reduce shrinkage stresses without negatively affecting the degree-of-cure or mechanical properties (elastic modulus and flexural strength).


Assuntos
Resinas Compostas , Dente Pré-Molar , Módulo de Elasticidade , Dureza , Teste de Materiais , Polimerização , Estresse Mecânico
15.
Oper Dent ; 43(6): E300-E307, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30457946

RESUMO

OBJECTIVE:: Cracks in amalgam-filled teeth may be related to amalgam expansion. This study measured cuspal flexure and used finite element analysis to assess associated stress levels in amalgam-filled teeth. METHODS AND MATERIALS:: External surfaces of 18 extracted molars were scanned in three dimensions. Nine molars were restored with mesio-occluso-distal amalgam fillings; the other teeth were left intact as controls. All teeth were stored in saline and scanned after two, four, and eight weeks. Cuspal flexure and restoration expansion were determined by calculating the difference between scanned surfaces. Stresses in a flexed tooth were calculated using finite element analysis. RESULTS:: Cusps of amalgam-filled teeth flexed outward approximately 3 µm, and restoration surfaces expanded 4 to 8 µm during storage. Cuspal flexure was significantly higher in the amalgam group (multivariate tests, p<0.05), but storage time had no significant effect (repeated measures, p>0.05). Expansion caused stress concentrations at the cavity line angles. These stress concentrations increased stresses due to mastication 44% to 178%. CONCLUSIONS:: Amalgam expansion pushed cavity walls outward, which created stress concentrations at the cavity line angles. Expansion stresses can raise stresses in amalgam-filled teeth and contribute to incidentally observed cracks.


Assuntos
Amálgama Dentário/química , Restauração Dentária Permanente/métodos , Adaptação Marginal Dentária , Materiais Dentários/química , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Técnicas In Vitro , Teste de Materiais , Dente Molar , Imagem Óptica , Polimerização , Propriedades de Superfície
16.
Oper Dent ; 43(1): 71-80, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28976847

RESUMO

OBJECTIVES: To analyze the effect of pulp-capping materials and resin composite light activation on strain and temperature development in the pulp and on the interfacial integrity at the pulpal floor/pulp-capping materials in large molar class II cavities. METHODS: Forty extracted molars received large mesio-occlusal-distal (MOD) cavity bur preparation with 1.0 mm of dentin remaining at the pulp floor. Four pulp-capping materials (self-etching adhesive system, Clearfil SE Bond [CLE], Kuraray), two light-curing calcium hydroxide cements (BioCal [BIO], Biodinâmica, and Ultra-Blend Plus [ULT], Ultradent), and a resin-modified glass ionomer cement- (Vitrebond [VIT], 3M ESPE) were applied on the pulpal floor. The cavities were incrementally restored with resin composite (Filtek Z350 XT, 3M ESPE). Thermocouple (n=10) and strain gauge (n=10) were placed inside the pulp chamber in contact with the top of the pulpal floor to detect temperature changes and dentin strain during light curing of the pulp-capping materials and during resin composite restoration. Exotherm was calculated by subtracting postcure from polymerization temperature (n=10). Interface integrity at the pulpal floor was investigated using micro-CT (SkyScan 1272, Bruker). The degree of cure of capping materials was calculated using the Fourier transform infrared and attenuated total reflectance cell. Data were analyzed using one-way analysis of variance followed by the Tukey test (α=0.05). RESULTS: Pulpal dentin strains (µs) during light curing of CLE were higher than for other pulp-capping materials ( p<0.001). During resin composite light activation, the pulpal dentin strain increased for ULT, VIT, and CLE and decreased for BIO. The pulpal dentin strain was significantly higher during pulp-capping light activation. The temperature inside the pulp chamber increased approximately 3.5°C after light curing the pulp-capping materials and approximately 2.1°C after final restoration. Pulp-capping material type had no influence temperature increase. The micro-CT showed perfect interfacial integrity after restoration for CLE and ULT; however, gaps were found between BIO and pulpal floor in all specimens. BIO had a significantly lower degree of conversion than ULT, VIT, and CLE. CONCLUSIONS: Light curing of pulp-capping materials caused deformation of pulpal dentin and increased pulpal temperature in large MOD cavities. Shrinkage of the resin composite restoration caused debonding of BIO from the pulpal floor.


Assuntos
Resinas Compostas/uso terapêutico , Polpa Dentária/efeitos da radiação , Dentina/efeitos da radiação , Cura Luminosa de Adesivos Dentários , Agentes de Capeamento da Polpa Dentária e Pulpectomia/efeitos da radiação , Temperatura Corporal , Polpa Dentária/efeitos dos fármacos , Dentina/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/efeitos adversos , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos , Técnicas In Vitro , Cura Luminosa de Adesivos Dentários/métodos
17.
Oper Dent ; 41(1): 23-33, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26237644

RESUMO

OBJECTIVES: To evaluate the effect of the restorative protocol on cuspal strain, fracture resistance, residual stress, and mechanical properties of restorative materials in endodontically treated molars. METHODS: Forty-five molars received mesio-occlusal-distal (MOD) Class II preparations and endodontic treatment followed by direct restorations using three restorative protocols: composite resin (CR) only (Filtek Supreme, 3M-ESPE), resin modified glass ionomer cement in combination with CR (Vitremer, 3M-ESPE in pulp chamber and Filtek Supreme in MOD cavity), conventional glass ionomer cement in combination with composite resin (CGI-CR) (Ketac Fil, 3M-ESPE in pulp chamber and Filtek Supreme in MOD cavity). Cuspal strain was measured using strain gauges, and fracture resistance was tested with an occlusal load. Elastic modulus (EM) and Vickers hardness (VH) of the restorative materials were determined at different depths using dynamic microhardness indentation. Curing shrinkage was measured using the strain gauge technique. The restorative protocols were also simulated in finite element analysis (FEA). The shrinkage strain, cuspal strain, EM, VH, and fracture resistance data were statistically analyzed using split-plot analysis of variance and Tukey test (p=0.05). Residual shrinkage stresses were expressed in modified von Mises equivalent stresses. RESULTS: Shrinkage strain values (in volume %) were Ketac Fil (0.08±0.01) < Vitremer (0.18±0.01) < Filtek Supreme (0.54±0.03). Cuspal strain was higher and fracture resistance was lower when using CR only compared with the techniques that used glass ionomer. The EM and VH of the materials in the pulp chamber were significantly lower for glass ionomer. The FEA showed that using CR only resulted in higher residual stresses in enamel and root dentin close to the pulp chamber than the combinations with glass ionomers (RMGI-CR and CGI-CR). CONCLUSIONS: The choice of restorative protocol significantly affected the biomechanical behavior of endodontically treated molars. Using glass ionomer to fill the pulp chamber is recommended when endodontically treated molars receive direct composite restorations because it reduces cuspal strain and increases fracture resistance.


Assuntos
Preparo da Cavidade Dentária , Restauração Dentária Permanente , Resinas Compostas , Materiais Dentários , Dureza , Dente Molar
18.
J Dent Res ; 95(5): 543-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26912221

RESUMO

The purpose of this study was to investigate the relationship between hygroscopic expansion and polymerization shrinkage for compensation of polymerization shrinkage stresses in a restored tooth. One resin-modified glass-ionomer (RMGI) (Ketac Nano, 3M ESPE), 2 compomers (Dyract, Dentsply; Compoglass, Ivoclar), and a universal resin-based composite (Esthet•X HD, Dentsply) were tested. Volumetric change after polymerization ("total shrinkage") and during 4 wk of water storage at 37°C was measured using an optical method (n= 10). Post-gel shrinkage was measured during polymerization using a strain gauge method (n= 10). Extracted human molars with large mesio-occluso-distal slot preparations were restored with the tested restorative materials. Tooth surfaces at baseline (preparation), after restoration, and during 4 wk of 37°C water storage were scanned with an optical scanner to determine cuspal flexure (n= 8). Occlusal interface integrity was measured using dye penetration. Data were analyzed using analysis of variance and post hoc tests (significance level 0.05). All tested materials shrunk after polymerization. RMGI had the highest total shrinkage (4.65%) but lowest post-gel shrinkage (0.35%). Shrinkage values dropped significantly during storage in water but had not completely compensated polymerization shrinkage after 4 wk. All restored teeth initially exhibited inward (negative) cuspal flexure due to polymerization shrinkage. Cuspal flexure with the RMGI restoration was significantly less (-6.4 µm) than with the other materials (-12.1 to -14.1 µm). After 1 d, cuspal flexure reversed to +5.0 µm cuspal expansion with the RMGI and increased to +9.3 µm at 4 wk. After 4 wk, hygroscopic expansion compensated cuspal flexure in a compomer (Compoglass) and reduced flexure with Dyract and resin-based composite. Marginal integrity (93.7% intact restoration wall) was best for the Compoglass restorations and lowest (73.1%) for the RMGI restorations. Hygroscopic expansion was more effective in compensating shrinkage stress than would be assumed based on total shrinkage, because only post-gel shrinkage needed compensation. Effective expansion is therefore hygroscopic expansion minus post-gel shrinkage.


Assuntos
Materiais Dentários/química , Corantes , Compômeros/química , Resinas Compostas/química , Preparo da Cavidade Dentária/classificação , Adaptação Marginal Dentária , Géis , Cimentos de Ionômeros de Vidro/química , Humanos , Cura Luminosa de Adesivos Dentários/instrumentação , Teste de Materiais , Imagem Óptica/instrumentação , Maleabilidade , Polimerização , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo , Coroa do Dente/anatomia & histologia , Água/química , Molhabilidade
19.
Oper Dent ; 41(5): 491-500, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26794188

RESUMO

OBJECTIVE: The aim of this study was to investigate the effect of delayed photo-activation on elastic modulus, Knoop hardness, and post-gel shrinkage of dual cure resin cements and how this affects residual shrinkage stresses in posterior teeth restored with ceramic inlays. METHODS AND MATERIALS: Four self-adhesive (RelyX Unicem, 3M ESPE; GCem, GC; MonoCem, Shofu; and seT, SDI) and two conventional (RelyX ARC, 3M ESPE; and AllCem, FGM) dual cure resin cements for cementing posterior ceramic inlays were tested. Strain gauge and indentation tests were used to measure the post-gel shrinkage (Shr), elastic modulus (E), and Knoop hardness (KHN) when photo-activated immediately and 3 and 5 minutes after placement (n=10). Shr, E, and KHN results were analyzed using two-way analysis of variance followed by Tukey honestly significant difference post hoc tests (α=0.05). The experimentally determined properties were applied in a finite element analysis of a leucite ceramic inlay (Empress CAD, Ivoclar Vivadent) cemented in a premolar. Modified von Mises stresses were evaluated at the occlusal margins and cavity floor. RESULTS: Shr, E, and KHN varied significantly among the resin cements (p<0.001). Highest overall Shr values were found for RelyX Unicem; GCem had the lowest. Increasing the photo-activation delay decreased Shr significantly. Delayed photo-activation had no effect on E (p=0.556) or KHN (p=0.927). RelyX Unicem had the highest E values; seT and MonoCem had the lowest E values. AllCem and RelyX Unicem had the highest KHN and MonoCem had the lowest KHN. Cements with high Shr and E values caused higher shrinkage stresses. Stresses decreased with delayed photo-activation for all cements. CONCLUSIONS: KHN and E values varied among the different resin cements. Residual shrinkage stress levels decreased with increasing photo-activation delay with all resin cements.

20.
Oper Dent ; 40(4): 364-71, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25535779

RESUMO

PURPOSE: When adding composite to a cured composite restoration, the intent is to achieve the same failure strength as the original restorative material. This study evaluated the failure strengths of added or repaired composite using various chemical and/or mechanical surface treatments. METHODS: Failure strengths were determined using a four-point bending test. Beam-shaped specimens were fabricated by adding new composite to cured composite (Filtek Supreme Ultra). The cured composites were either fresh or aged seven days (N=10-14). The composite surfaces were left unground or were ground before treatment with various combinations of roughening, acid etching, silane, and dental adhesives (conventional Adper SingleBond Plus or new multimode Scotchbond Universal) and/or tribochemistry (CoJet system). Monolithic composite specimens were the control. Failure strengths were statistically analyzed using one-way analysis of variance and the Fisher protected least significant difference (α=0.05). RESULTS: Failure strengths (mean ± standard deviation) when composite was added to unground freshly cured composites (111±25 MPa) and aged composites using a new multimode adhesive with (102±22 MPa) or without (98±22 MPa) tribochemical treatment were not significantly lower than the monolithic specimens (122±23 MPa). Grinding the surfaces of freshly cured composite significantly reduced failure strength, either with (81±30 MPa) or without (86±31 MPa) use of conventional adhesive. Failure strengths of aged composites were also significantly lower (51±21 MPa with SingleBond Plus), even after tribochemical treatment (71±29 MPa with SingleBond Plus; 73±35 MPa with Silane-Visiobond). CONCLUSIONS: Using a new multimode adhesive when adding composite to freshly cured or aged composite substrates recovered the failure strength to that of the original monolithic composite.


Assuntos
Resinas Compostas , Colagem Dentária , Cimentos Dentários , Falha de Restauração Dentária , Reparação de Restauração Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato , Análise do Estresse Dentário , Adesivos Dentinários , Técnicas In Vitro , Teste de Materiais , Cimentos de Resina , Silanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA