Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Physiol ; 594(21): 6333-6347, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27273807

RESUMO

KEY POINTS: Pulmonary perfusion measurement using magnetic resonance imaging combined with deformable image registration enabled us to quantify the change in the spatial distribution of pulmonary perfusion at different lung volumes. The current study elucidated the effects of tidal volume lung inflation [functional residual capacity (FRC) + 500 ml and FRC + 1 litre] on the change in pulmonary perfusion distribution. Changes in hydrostatic pressure distribution as well as transmural pressure distribution due to the change in lung height with tidal volume inflation are probably bigger contributors to the redistribution of pulmonary perfusion than the changes in pulmonary vasculature resistance caused by lung tissue stretch. ABSTRACT: Tidal volume lung inflation results in structural changes in the pulmonary circulation, potentially affecting pulmonary perfusion. We hypothesized that perfusion is recruited to regions receiving the greatest deformation from a tidal breath, thus ensuring ventilation-perfusion matching. Density-normalized perfusion (DNP) magnetic resonance imaging data were obtained in healthy subjects (n = 7) in the right lung at functional residual capacity (FRC), FRC+500 ml, and FRC+1.0 l. Using deformable image registration, the displacement of a sagittal lung slice acquired at FRC to the larger volumes was calculated. Registered DNP images were normalized by the mean to estimate perfusion redistribution (nDNP). Data were evaluated across gravitational regions (dependent, middle, non-dependent) and by lobes (upper, RUL; middle, RML; lower, RLL). Lung inflation did not alter mean DNP within the slice (P = 0.10). The greatest expansion was seen in the dependent region (P < 0.0001: dependent vs non-dependent, P < 0.0001: dependent vs middle) and RLL (P = 0.0015: RLL vs RUL, P < 0.0001: RLL vs RML). Neither nDNP recruitment to RLL [+500 ml = -0.047(0.145), +1 litre = 0.018(0.096)] nor to dependent lung [+500 ml = -0.058(0.126), +1 litre = -0.023(0.106)] were found. Instead, redistribution was seen in decreased nDNP in the non-dependent [+500 ml = -0.075(0.152), +1 litre = -0.137(0.167)) and increased nDNP in the gravitational middle lung [+500 ml = 0.098(0.058), +1 litre = 0.093(0.081)] (P = 0.01). However, there was no significant lobar redistribution (P < 0.89). Contrary to our hypothesis, based on the comparison between gravitational and lobar perfusion data, perfusion was not redistributed to the regions of the most inflation. This suggests that either changes in hydrostatic pressure or transmural pressure distribution in the gravitational direction are implicated in the redistribution of perfusion away from the non-dependent lung.


Assuntos
Inalação , Pulmão/fisiologia , Circulação Pulmonar , Adulto , Feminino , Humanos , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Volume de Ventilação Pulmonar
2.
Artigo em Inglês | MEDLINE | ID: mdl-23367125

RESUMO

To evaluate the nature of small scale lung deformation between multiple pulmonary magnetic resonance images, two different kinematic intensity based image registration techniques: affine and bicubic Hermite interpolation were tested. The affine method estimates uniformly distributed deformation metrics throughout the lung. The bicubic Hermite method allows the expression of heterogeneously distributed deformation metrics such as Lagrangian strain. A cardiac triggered inversion recovery technique was used to obtain 10 sequential images of pulmonary vessel structure in a sagittal plane in the right lung at FRC in 4 healthy subjects (Age: 28.5(6.2)). One image was used as the reference image, and the remaining images (target images) were warped onto the reference image using both image registration techniques. The normalized correlation between the reference and the transformed target images within the lung domain was used as a cost function for optimization, and the root mean square (RMS) of image intensity difference was used to evaluate the quality of the registration. Both image registration techniques significantly improved the RMS compared with non-registered target images (p= 0.04). The spatial mean (µE) and standard deviation (σ(E)) of Lagrangian strain were computed based on the spatial distribution of lung deformation approximated by the bicubic Hermite method, and were measured on the order of 10(-3) or less, which is virtually negligible. As a result, small scale lung deformation between FRC lung volumes is spatially uniform, and can be simply characterized by affine deformation even though the bicubic Hermite method is capable of expressing complicated spatial patterns of lung deformation.


Assuntos
Pulmão/anormalidades , Adulto , Fenômenos Biomecânicos , Humanos , Imageamento por Ressonância Magnética , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA