Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 76: 232-243, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34182119

RESUMO

BACKGROUND: The purpose of this study was to examine the incidence of acute kidney injury and chronic renal impairment following branched endovascular aneurysm repair (BEVAR) of complex thoracoabdominal aortic aneurysms (TAAA) using the Medtronic Valiant Thoracoabdominal Aortic Aneurysm stent graft system (MVM), the physician-modified Visceral Manifold, and Unitary Manifold stent graft systems. The objective was to report the acute and chronic renal function changes in patients following complex TAAA aneurysm repair. METHODS: This is an analysis of 139 patients undergoing branched endovascular repair for complex TAAAs between 2012 and 2020. Patient renal function was evaluated using serum creatinine and estimated glomerular filtration rate at baseline, 48 hr, discharge, 1 month, 6 months, and annually to 2 years. Patients on dialysis prior to the procedure were excluded from data analysis. RESULTS: A total of 139 patients (mean age 71.13; 64.7% male) treated for TAAA with BEVAR met inclusion criteria and were evaluated. A total of 530 visceral vessels were stented. A majority of patients (n = 131, 94.2%) underwent a single procedure while 8 required staged procedures. Thirty-day, 1-year and 2-year all-cause mortality rates were 5.8%, 25.2%, and 32.4%, respectively. Primary and secondary patency rates at a median follow-up of 26.9 months (95% CI; 21.1 - 32.7) were 96.2% and 97.5% for all vessels and 95.4% and 96.9% for renal arteries, respectively. Postoperative acute kidney injury (AKI) was identified in 22 (15.8%) patients. At discharge, 16 patients (11.6%) had an increase in CKD stage with 3 requiring permanent dialysis. Five additional patients required permanent dialysis over the 2-year follow-up period for a total of 8 (5.8%). Increasing age (HR = 1.0327, P= 0.0477), hemoglobin < 7 prior to procedure (HR = 2.4812, P= 0.0093), increasing maximum aortic diameter (HR = 1.0189, P= 0.0084), presence of AKI (HR = 2.0757, P= 0.0182), and increase in CKD stage (HR = 1.3520, P= 0.002) at discharge were significantly associated with decreased patient survival. CONCLUSIONS: Postoperative AKI and a chronic decline in renal function continue to be problematic in endovascular repair of complex aortic aneurysms. This study found that BEVAR using the manifold configuration resulted in immediate and mid-term renal function that is comparable to similar analyses of branched and/or fenestrated grafts.


Assuntos
Injúria Renal Aguda/epidemiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Falência Renal Crônica/epidemiologia , Injúria Renal Aguda/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/epidemiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Incidência , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA