Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Angiogenesis ; 27(1): 37-49, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37493987

RESUMO

Modern drug development increasingly requires comprehensive models that can be utilized in the earliest stages of compound and target discovery. Here we report a phenotypic screening exercise in a high-throughput Organ-on-a-Chip setup. We assessed the inhibitory effect of 1537 protein kinase inhibitors in an angiogenesis assay. Over 4000 micro-vessels were grown under perfusion flow in microfluidic chips, exposed to a cocktail of pro-angiogenic factors and subsequently exposed to the respective kinase inhibitors. Efficacy of compounds was evaluated by reduced angiogenic sprouting, whereas reduced integrity of the main micro-vessel was taken as a measure for toxicity. The screen yielded 53 hits with high anti-angiogenicity and low toxicity, of which 44 were previously unassociated with angiogenic pathways. This study demonstrates that Organ-on-a-Chip models can be screened in high numbers to identify novel compounds and targets. This will ultimately reduce bias in early-stage drug development and increases probability to identify first in class compounds and targets for today's intractable diseases.


Assuntos
Angiogênese , Antineoplásicos , Humanos , Sistemas Microfisiológicos , Antineoplásicos/uso terapêutico , Neovascularização Patológica/tratamento farmacológico , Inibidores de Proteínas Quinases/farmacologia
2.
Angiogenesis ; 25(4): 455-470, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35704148

RESUMO

With recent progress in modeling liver organogenesis and regeneration, the lack of vasculature is becoming the bottleneck in progressing our ability to model human hepatic tissues in vitro. Here, we introduce a platform for routine grafting of liver and other tissues on an in vitro grown microvascular bed. The platform consists of 64 microfluidic chips patterned underneath a 384-well microtiter plate. Each chip allows the formation of a microvascular bed between two main lateral vessels by inducing angiogenesis. Chips consist of an open-top microfluidic chamber, which enables addition of a target tissue by manual or robotic pipetting. Upon grafting a liver microtissue, the microvascular bed undergoes anastomosis, resulting in a stable, perfusable vascular network. Interactions with vasculature were found in spheroids and organoids upon 7 days of co-culture with space of Disse-like architecture in between hepatocytes and endothelium. Veno-occlusive disease was induced by azathioprine exposure, leading to impeded perfusion of the vascularized spheroid. The platform holds the potential to replace animals with an in vitro alternative for routine grafting of spheroids, organoids, or (patient-derived) explants.


Assuntos
Microfluídica , Organoides , Animais , Azatioprina , Técnicas de Cocultura , Humanos , Fígado , Microfluídica/métodos
3.
J Neurochem ; 157(3): 393-412, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33382092

RESUMO

Amyotrophic lateral sclerosis (ALS) is a fatal and progressive neurodegenerative disease affecting upper and lower motor neurons with no cure available. Clinical and animal studies reveal that the neuromuscular junction (NMJ), a synaptic connection between motor neurons and skeletal muscle fibers, is highly vulnerable in ALS and suggest that NMJ defects may occur at the early stages of the disease. However, mechanistic insight into how NMJ dysfunction relates to the onset and progression of ALS is incomplete, which hampers therapy development. This is, in part, caused by a lack of robust in vitro models. The ability to combine microfluidic and induced pluripotent stem cell (iPSC) technologies has opened up new avenues for studying molecular and cellular ALS phenotypes in vitro. Microfluidic devices offer several advantages over traditional culture approaches when modeling the NMJ, such as the spatial separation of different cell types and increased control over the cellular microenvironment. Moreover, they are compatible with 3D cell culture, which enhances NMJ functionality and maturity. Here, we review how microfluidic technology is currently being employed to develop more reliable in vitro NMJ models. To validate and phenotype such models, various morphological and functional read-outs have been developed. We describe and discuss the relevance of these read-outs and specifically illustrate how these read-outs have enhanced our understanding of NMJ pathology in ALS. Finally, we share our view on potential future directions and challenges.


Assuntos
Esclerose Lateral Amiotrófica/fisiopatologia , Simulação por Computador , Dispositivos Lab-On-A-Chip , Microfluídica/métodos , Junção Neuromuscular/fisiopatologia , Animais , Humanos , Neurônios Motores/patologia
4.
Int J Mol Sci ; 21(14)2020 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-32674311

RESUMO

Intestinal organoids have emerged as the new paradigm for modelling the healthy and diseased intestine with patient-relevant properties. In this study, we show directed differentiation of induced pluripotent stem cells towards intestinal-like phenotype within a microfluidic device. iPSCs are cultured against a gel in microfluidic chips of the OrganoPlate, in which they undergo stepwise differentiation. Cells form a tubular structure, lose their stem cell markers and start expressing mature intestinal markers, including markers for Paneth cells, enterocytes and neuroendocrine cells. Tubes develop barrier properties as confirmed by transepithelial electrical resistance (TEER). Lastly, we show that tubules respond to pro-inflammatory cytokine triggers. The whole procedure for differentiation lasts 14 days, making it an efficient process to make patient-specific organoid tubules. We anticipate the usage of the platform for disease modelling and drug candidate screening.


Assuntos
Diferenciação Celular/fisiologia , Células-Tronco Pluripotentes Induzidas/citologia , Intestinos/citologia , Biomarcadores/metabolismo , Células CACO-2 , Linhagem Celular , Linhagem Celular Tumoral , Citocinas/metabolismo , Enterócitos/citologia , Enterócitos/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Inflamação/metabolismo , Dispositivos Lab-On-A-Chip , Células Neuroendócrinas/citologia , Células Neuroendócrinas/metabolismo , Organoides/citologia , Organoides/metabolismo , Celulas de Paneth/citologia , Celulas de Paneth/metabolismo
5.
Int J Mol Sci ; 21(13)2020 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-32645937

RESUMO

To advance pre-clinical vascular drug research, in vitro assays are needed that closely mimic the process of angiogenesis in vivo. Such assays should combine physiological relevant culture conditions with robustness and scalability to enable drug screening. We developed a perfused 3D angiogenesis assay that includes endothelial cells (ECs) from induced pluripotent stem cells (iPSC) and assessed its performance and suitability for anti-angiogenic drug screening. Angiogenic sprouting was compared with primary ECs and showed that the microvessels from iPSC-EC exhibit similar sprouting behavior, including tip cell formation, directional sprouting and lumen formation. Inhibition with sunitinib, a clinically used vascular endothelial growth factor (VEGF) receptor type 2 inhibitor, and 3-(3-pyridinyl)-1-(4-pyridinyl)-2-propen-1-one (3PO), a transient glycolysis inhibitor, both significantly reduced the sprouting of both iPSC-ECs and primary ECs, supporting that both cell types show VEGF gradient-driven angiogenic sprouting. The assay performance was quantified for sunitinib, yielding a minimal signal window of 11 and Z-factor of at least 0.75, both meeting the criteria to be used as screening assay. In conclusion, we have developed a robust and scalable assay that includes physiological relevant culture conditions and is amenable to screening of anti-angiogenic compounds.


Assuntos
Inibidores da Angiogênese/farmacologia , Bioensaio/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Endotélio/efeitos dos fármacos , Células-Tronco Pluripotentes Induzidas/efeitos dos fármacos , Neovascularização Patológica/tratamento farmacológico , Neovascularização Fisiológica/efeitos dos fármacos , Técnicas de Cultura de Células/métodos , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Endotélio/metabolismo , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Microvasos/efeitos dos fármacos , Microvasos/metabolismo , Neovascularização Patológica/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo
6.
Int J Mol Sci ; 20(18)2019 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-31546820

RESUMO

Pancreatic Ductal Adenocarcinoma (PDAC) is one of the most lethal cancers due to a high chemoresistance and poor vascularization, which results in an ineffective systemic therapy. PDAC is characterized by a high intratumoral pressure, which is not captured by current 2D and 3D in vitro models. Here, we demonstrated a 3D microfluidic interstitial flow model to mimic the intratumoral pressure in PDAC. We found that subjecting the S2-028 PDAC cell line to interstitial flow inhibits the proliferation, while maintaining a high viability. We observed increased gemcitabine chemoresistance, with an almost nine-fold higher EC50 as compared to a monolayer culture (31 nM versus 277 nM), and an alleviated expression and function of the multidrug resistance protein (MRP) family. In conclusion, we developed a 3D cell culture modality for studying intratissue pressure and flow that exhibits more predictive capabilities than conventional 2D cell culture and is less time-consuming, and more scalable and accessible than animal models. This increase in microphysiological relevance might support improved efficiency in the drug development pipeline.


Assuntos
Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Carcinoma Ductal Pancreático/metabolismo , Desoxicitidina/análogos & derivados , Resistencia a Medicamentos Antineoplásicos/efeitos dos fármacos , Intestino Delgado/metabolismo , Técnicas Analíticas Microfluídicas , Modelos Biológicos , Proteínas de Neoplasias/metabolismo , Neoplasias Pancreáticas/metabolismo , Carcinoma Ductal Pancreático/patologia , Linhagem Celular Tumoral , Desoxicitidina/farmacologia , Humanos , Intestino Delgado/patologia , Dispositivos Lab-On-A-Chip , Neoplasias Pancreáticas/patologia , Gencitabina
7.
Int J Mol Sci ; 20(22)2019 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-31726729

RESUMO

A common bottleneck in any drug development process is finding sufficiently accurate models that capture key aspects of disease development and progression. Conventional drug screening models often rely on simple 2D culture systems that fail to recapitulate the complexity of the organ situation. In this study, we show the application of a robust high throughput 3D gut-on-a-chip model for investigating hallmarks of inflammatory bowel disease (IBD). Using the OrganoPlate platform, we subjected enterocyte-like cells to an immune-relevant inflammatory trigger in order to recapitulate key events of IBD and to further investigate the suitability of this model for compound discovery and target validation activities. The induction of inflammatory conditions caused a loss of barrier function of the intestinal epithelium and its activation by increased cytokine production, two events observed in IBD physiopathology. More importantly, anti-inflammatory compound exposure prevented the loss of barrier function and the increased cytokine release. Furthermore, knockdown of key inflammatory regulators RELA and MYD88 through on-chip adenoviral shRNA transduction alleviated IBD phenotype by decreasing cytokine production. In summary, we demonstrate the routine use of a gut-on-a-chip platform for disease-specific aspects modeling. The approach can be used for larger scale disease modeling, target validation and drug discovery purposes.


Assuntos
Descoberta de Drogas , Doenças Inflamatórias Intestinais , Procedimentos Analíticos em Microchip , Modelos Biológicos , Células CACO-2 , Avaliação Pré-Clínica de Medicamentos , Técnicas de Inativação de Genes , Humanos , Doenças Inflamatórias Intestinais/tratamento farmacológico , Doenças Inflamatórias Intestinais/genética , Doenças Inflamatórias Intestinais/metabolismo , Doenças Inflamatórias Intestinais/patologia , Dispositivos Lab-On-A-Chip , Fator 88 de Diferenciação Mieloide/genética , Fator 88 de Diferenciação Mieloide/metabolismo , Fator de Transcrição RelA/genética , Fator de Transcrição RelA/metabolismo
8.
BMC Cancer ; 17(1): 709, 2017 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-29096610

RESUMO

BACKGROUND: Breast cancer is the most common invasive cancer among women. Currently, there are only a few models used for therapy selection, and they are often poor predictors of therapeutic response or take months to set up and assay. In this report, we introduce a microfluidic OrganoPlate® platform for extracellular matrix (ECM) embedded tumor culture under perfusion as an initial study designed to investigate the feasibility of adapting this technology for therapy selection. METHODS: The triple negative breast cancer cell lines MDA-MB-453, MDA-MB-231 and HCC1937 were selected based on their different BRCA1 and P53 status, and were seeded in the platform. We evaluate seeding densities, ECM composition (Matrigel®, BME2rgf, collagen I) and biomechanical (perfusion vs static) conditions. We then exposed the cells to a series of anti-cancer drugs (paclitaxel, olaparib, cisplatin) and compared their responses to those in 2D cultures. Finally, we generated cisplatin dose responses in 3D cultures of breast cancer cells derived from 2 PDX models. RESULTS: The microfluidic platform allows the simultaneous culture of 96 perfused micro tissues, using limited amounts of material, enabling drug screening of patient-derived material. 3D cell culture viability is improved by constant perfusion of the medium. Furthermore, the drug response of these triple negative breast cancer cells was attenuated by culture in 3D and differed from that observed in 2D substrates. CONCLUSIONS: We have investigated the use of a high-throughput organ-on-a-chip platform to select therapies. Our results have raised the possibility to use this technology in personalized medicine to support selection of appropriate drugs and to predict response to therapy in a real time fashion.


Assuntos
Antineoplásicos/farmacologia , Técnicas de Cultura de Células/métodos , Matriz Extracelular/metabolismo , Microfluídica/métodos , Proteína BRCA1/metabolismo , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Cisplatino/farmacologia , Colágeno , Combinação de Medicamentos , Feminino , Humanos , Laminina , Mutação , Avaliação de Resultados em Cuidados de Saúde/métodos , Paclitaxel/farmacologia , Ftalazinas/farmacologia , Piperazinas/farmacologia , Prognóstico , Proteoglicanas , Neoplasias de Mama Triplo Negativas/genética , Neoplasias de Mama Triplo Negativas/metabolismo , Neoplasias de Mama Triplo Negativas/patologia , Proteína Supressora de Tumor p53/genética , Proteína Supressora de Tumor p53/metabolismo
9.
Anal Chem ; 86(9): 4078-87, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24670194

RESUMO

Isotachophoresis (ITP) and electric field gradient focusing (EFGF) are two powerful approaches for simultaneous focusing and separation of charged compounds. Remarkably, in many EFGF methods, isotachophoretic hallmarks have been found, including observations of plateau concentrations and contiguous analyte bands. We discuss the similarities between ITP and EFGF and describe promising possibilities to transfer the functionality and applications developed on one platform to other platforms. Of particular importance is the observation that single-electrolyte isotachophoretic separations with tunable ionic mobility window can be performed, as is illustrated with the example of depletion zone isotachophoresis (dzITP). By exploiting the rapid developments in micro- and nanofluidics, many interesting combinations of ITP and EFGF features can be achieved, yielding powerful analytical platforms for sample preparation, biomarker discovery, molecular interaction assays, drug screening, and clinical diagnostics.


Assuntos
Bioensaio , Eletricidade , Isotacoforese
10.
Anal Chem ; 86(16): 8048-56, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-24892382

RESUMO

We present a continuous-flow microelectroextraction flow cell that allows for electric field enhanced extraction of analytes from a large volume (1 mL) of continuously flowing donor phase into a micro volume of stagnant acceptor phase (13.4 µL). We demonstrate for the first time that the interface between the stagnant acceptor phase and fast-flowing donor phase can be stabilized by a phaseguide. Chip performance was assessed by visual experiments using crystal violet. Then, extraction of a mixture of acylcarnitines was assessed by off-line coupling to reversed phase liquid chromatography coupled to time-of-flight mass spectrometry, resulting in concentration factors of 80.0 ± 9.2 times for hexanoylcarnitine, 73.8 ± 9.1 for octanoylcarnitine, and 34.1 ± 4.7 times for lauroylcarnitine, corresponding to recoveries of 107.8 ± 12.3%, 98.9 ± 12.3%, and 45.7 ± 6.3%, respectively, in a sample of 500 µL delivered at a flow of 50 µL min(-1) under an extraction voltage of 300 V. Finally, the method was applied to the analysis of acylcarnitines spiked to urine, resulting in detection limits as low as 0.3-2 nM. Several putative endogenous acylcarnitines were found. The current flowing-to-stagnant phase microelectroextraction setup allows for the extraction of milliliter range volumes and is, as a consequence, very suited for analysis of low-abundant metabolites.


Assuntos
Carnitina/análogos & derivados , Técnicas Eletroquímicas/instrumentação , Lauratos/isolamento & purificação , Extração em Fase Sólida/instrumentação , Carnitina/isolamento & purificação , Carnitina/urina , Cromatografia de Fase Reversa , Desenho de Equipamento , Humanos , Lauratos/urina , Limite de Detecção , Espectrometria de Massas
11.
Sci Rep ; 14(1): 11157, 2024 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834598

RESUMO

Snakebite envenomation is a major public health issue which causes severe morbidity and mortality, affecting millions of people annually. Of a diverse range of clinical manifestations, local and systemic haemorrhage are of particular relevance, as this may result in ischemia, organ failure and even cardiovascular shock. Thus far, in vitro studies have failed to recapitulate the haemorrhagic effects observed in vivo. Here, we present an organ-on-a-chip approach to investigate the effects of four different snake venoms on a perfused microfluidic blood vessel model. We assess the effect of the venoms of four snake species on epithelial barrier function, cell viability, and contraction/delamination. Our findings reveal two different mechanisms by which the microvasculature is being affected, either by disruption of the endothelial cell membrane or by delamination of the endothelial cell monolayer from its matrix. The use of our blood vessel model may shed light on the key mechanisms by which tissue-damaging venoms exert their effects on the capillary vessels, which could be helpful for the development of effective treatments against snakebites.


Assuntos
Dispositivos Lab-On-A-Chip , Venenos de Serpentes , Animais , Humanos , Células Endoteliais/efeitos dos fármacos , Hemorragia , Sobrevivência Celular/efeitos dos fármacos , Mordeduras de Serpentes/tratamento farmacológico , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Sistemas Microfisiológicos
12.
Anal Chem ; 85(12): 5734-9, 2013 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-23679001

RESUMO

We report the use of pendant droplet evaporation for exchange of eluents for (1)H nuclear magnetic resonance ((1)H NMR) purposes. Analytes are fed and retained in 500 nL droplets, which are concentrated by evaporation and subsequently redissolved in deuterated solvent. Droplet size is monitored by machine vision (MV), and heating rates are adjusted concordingly to maintain a stable droplet volume. Evaporation control is independent of solvent properties, and the setup handles feed rates up to 7 µL min(-1). The interface is capable of exchanging up to 90% of solvent for deuterated solvent, with a good recovery and repeatability for tomato extracts (Solanum lycopersicum). The system was capable of handling both polar and nonpolar analytes in one run. Volatiles such as formate, acetate, and lactate and the thermosensitive compound epigallocatechin gallate were recovered without significant losses. Ethanol and propionate were recovered with significant losses due to the formation of a minimum boiling azeotrope. The current setup is ideally suited for on- and off-line hyphenation of liquid chromatography and NMR, as it is comprehensive, fully automated, and easy to operate.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Solventes/química , Água/química , Cromatografia Líquida/métodos , Extratos Vegetais/análise
13.
Acta Biomater ; 164: 363-376, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37116636

RESUMO

Pathologies associated with uteroplacental hypoxia, such as preeclampsia are among the leading causes of maternal and perinatal morbidity in the world. Its fundamental mechanisms are yet poorly understood due to a lack of good experimental models. Here we report an in vitro model of the placental barrier, based on co-culture of trophoblasts and endothelial cells against a collagen extracellular matrix in a microfluidic platform. The model yields a functional syncytium with barrier properties, polarization, secretion of relevant extracellular membrane components, thinning of the materno-fetal space, hormone secretion, and transporter function. The model is exposed to low oxygen conditions and perfusion flow is modulated to induce a pathological environment. This results in reduced barrier function, hormone secretion, and microvilli as well as an increased nuclei count, characteristics of preeclamptic placentas. The model is implemented in a titer plate-based microfluidic platform fully amenable to high-throughput screening. We thus believe this model could aid mechanistic understanding of preeclampsia and other placental pathologies associated with hypoxia/ischemia, as well as support future development of effective therapies through target and compound screening campaigns. STATEMENT OF SIGNIFICANCE: The human placenta is a unique organ sustaining fetal growth but is also the source of severe pathologies, such as preeclampsia. Though leading cause of perinatal mortality in the world, preeclampsia remains untreatable due to a lack of relevant in vitro placenta models. To better understand the pathology, we have developed 3D placental barrier models in a microfluidic device. The platform allows parallel culture of 40 perfused physiological miniaturized placental barriers, comprising a differentiated syncytium and endothelium that have been validated for transporter functions. Exposure to a hypoxic and ischemic environment enabled the mimicking of preeclamptic characteristics in high-throughput, which we believe could lead to a better understanding of the pathology as well as support future effective therapies development.


Assuntos
Placenta , Pré-Eclâmpsia , Gravidez , Feminino , Humanos , Células Endoteliais , Hipóxia , Isquemia , Dispositivos Lab-On-A-Chip , Hormônios
14.
Anal Chem ; 84(21): 9065-71, 2012 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-23013213

RESUMO

We present a novel concept of filtering based on depletion zone isotachophoresis (dzITP). In the micro/nanofluidic filter, compounds are separated according to isotachophoretic principles and simultaneously released selectively along a nanochannel-induced depletion zone. Thus, a tunable low-pass ionic mobility filter is realized. We demonstrate quantitative control of the release of fluorescent compounds through the filter using current and voltage actuation. Two modes of operation are presented. In continuous mode, supply, focusing, and separation are synchronized with continuous compound release, resulting in trapping of specific compounds. In pulsed mode, voltage pulses result in release of discrete zones. The dzITP filter was used to enhance detection of 6-carboxyfluorescein 4-fold over fluorescein, even though it had 250× lower starting concentration. Moreover, specific high-mobility analytes were extracted and enriched from diluted raw urine, using fluorescein as an ionic mobility cutoff marker and as a tracer for indirect detection. Tunable ionic filtering is a simple but essential addition to the capabilities of dzITP as a versatile toolkit for biochemical assays.


Assuntos
Filtração/métodos , Isotacoforese/métodos , Movimento (Física)
15.
Methods Mol Biol ; 2373: 87-105, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34520008

RESUMO

The study of epithelial barrier properties in the human body is of paramount interest to a range of disciplines, including disease modeling, drug transport studies, toxicology, developmental biology, and regenerative biology. Current day in vitro studies largely rely on growing epithelial cells in a static environment on membrane cell culture inserts. With the advancement of microfluidic and organ-on-a-chip techniques it became possible to culture 3D intestinal tubules directly against an extracellular matrix (ECM) under flow and without the need for artificial membranes. Here we describe detailed protocols for culturing epithelial tubules in a high-throughput format, assessing their permeability and marker expression. The platform harbors 40 independent microfluidic chips in a microtiter plate format. The resulting 40 epithelial tubules are analyzed in parallel using a high-content microscopy. Protocols described here allow for adoption and routine application of microfluidic techniques by nonspecialized end-users.


Assuntos
Mucosa Intestinal , Dispositivos Lab-On-A-Chip , Técnicas de Cultura de Células , Células Epiteliais , Humanos , Microfluídica
16.
Kidney360 ; 3(2): 217-231, 2022 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-35373131

RESUMO

Background: Renal ischemia/reperfusion injury (rIRI) is one of the major causes of AKI. Although animal models are suitable for investigating systemic symptoms of AKI, they are limited in translatability. Human in vitro models are crucial in giving mechanistic insights into rIRI; however, they miss out on crucial aspects such as reperfusion injury and the multitissue aspect of AKI. Methods: We advanced the current renal proximal tubule-on-a-chip model to a coculture model with a perfused endothelial vessel separated by an extracellular matrix. The coculture was characterized for its three-dimensional structure, protein expression, and response to nephrotoxins. Then, rIRI was captured through control of oxygen levels, nutrient availability, and perfusion flow settings. Injury was quantified through morphologic assessment, caspase-3/7 activation, and cell viability. Results: The combination of low oxygen, reduced glucose, and interrupted flow was potent to disturb the proximal tubules. This effect was strongly amplified upon reperfusion. Endothelial vessels were less sensitive to the ischemia-reperfusion parameters. Adenosine treatment showed a protective effect on the disruption of the epithelium and on the caspase-3/7 activation. Conclusions: A human in vitro rIRI model was developed using a coculture of a proximal tubule and blood vessel on-a-chip, which was used to characterize the renoprotective effect of adenosine. The robustness of the model and assays in combination with the throughput of the platform make it ideal to advance pathophysiological research and enable the development of novel therapeutic modalities.


Assuntos
Injúria Renal Aguda , Dispositivos Lab-On-A-Chip , Injúria Renal Aguda/prevenção & controle , Animais , Humanos , Isquemia/complicações , Túbulos Renais/metabolismo , Reperfusão/efeitos adversos
17.
Sci Rep ; 12(1): 16930, 2022 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-36209279

RESUMO

In early systemic sclerosis (Scleroderma, SSc), the vasculature is impaired. Although the exact etiology of endothelial cell damage in SSc remains unclear, it is hypothesized that endothelial to mesenchymal transition (EndoMT) plays a key role. To perform physiologically relevant angiogenic studies, we set out to develop an angiogenesis-on-a-chip platform that is suitable for assessing disease parameters that are relevant to SSc and other vasculopathies. In the model, we substituted Fetal Bovine Serum (FBS) with Human Serum without impairing the stability of the culture. We showed that 3D microvessels and angiogenic factor-induced sprouts exposed to key pro-inflammatory and pro-fibrotic cytokines (TNFα and TGFß) undergo structural alterations consisting of destructive vasculopathy (loss of small vessels). We also showed that these detrimental effects can be prevented by compound-mediated inhibition of TGFß-ALK5 signaling or addition of a TNFα neutralizing antibody to the 3D cultures. This demonstrates that our in vitro model is suitable for compound testing and identification of new drugs that can protect from microvascular destabilization or regression in disease-mimicking conditions. To support this, we demonstrated that sera obtained from SSc patients can exert an anti-angiogenic effect on the 3D vessel model, opening the doors to screening for potential SSc drugs, enabling direct patient translatability and personalization of drug treatment.


Assuntos
Escleroderma Sistêmico , Fator de Necrose Tumoral alfa , Indutores da Angiogênese , Anticorpos Neutralizantes , Humanos , Dispositivos Lab-On-A-Chip , Microvasos , Neovascularização Patológica , Soroalbumina Bovina , Fator de Crescimento Transformador beta
18.
Anal Chem ; 83(20): 7910-5, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21861489

RESUMO

Isotachophoretic separations are triggered at the border of a nanochannel-induced ion-depleted zone. This depletion zone acts as a terminating electrolyte and is created by concentration polarization over the nanochannel. We show both continuous and discrete sample injections as well as separation of up to four analytes. Continuous injection of a spacer compound was used for selective analyte elution. Zones were kept focused for over one hour, while shifting less than 700 µm. Moreover, zones could be deliberately positioned in the separation channel and focusing strength could be precisely tuned employing a three-point voltage actuation scheme. This makes depletion zone isotachophoresis (dzITP) a fully controllable single-electrolyte focusing and separation technique. For on-chip electrokinetic methods, dzITP sets a new standard in terms of versatility and operational simplicity.


Assuntos
Eletrólitos/química , Isotacoforese/métodos , Íons/química , Isotacoforese/instrumentação , Nanotecnologia
19.
Sci Rep ; 11(1): 2080, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33483540

RESUMO

We report a method to generate a 3D motor neuron model with segregated and directed axonal outgrowth. iPSC-derived motor neurons are cultured in extracellular matrix gel in a microfluidic platform. Neurons extend their axons into an adjacent layer of gel, whereas dendrites and soma remain predominantly in the somal compartment, as verified by immunofluorescent staining. Axonal outgrowth could be precisely quantified and was shown to respond to the chemotherapeutic drug vincristine in a highly reproducible dose-dependent manner. The model was shown susceptible to excitotoxicity upon exposure with excess glutamate and showed formation of stress granules upon excess glutamate or sodium arsenite exposure, mimicking processes common in motor neuron diseases. Importantly, outgrowing axons could be attracted and repelled through a gradient of axonal guidance cues, such as semaphorins. The platform comprises 40 chips arranged underneath a microtiter plate providing both throughput and compatibility to standard laboratory equipment. The model will thus prove ideal for studying axonal biology and disease, drug discovery and regenerative medicine.


Assuntos
Axônios/fisiologia , Modelos Biológicos , Neurônios Motores/fisiologia , Neuritos , Animais , Antineoplásicos/farmacologia , Materiais Biocompatíveis , Células Cultivadas , Ácido Glutâmico/farmacologia , Células-Tronco Pluripotentes Induzidas/citologia , Microfluídica , Neuritos/efeitos dos fármacos , Vincristina/farmacologia
20.
Fluids Barriers CNS ; 18(1): 59, 2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-34906183

RESUMO

BACKGROUND: In ischemic stroke, the function of the cerebral vasculature is impaired. This vascular structure is formed by the so-called neurovascular unit (NVU). A better understanding of the mechanisms involved in NVU dysfunction and recovery may lead to new insights for the development of highly sought therapeutic approaches. To date, there remains an unmet need for complex human in vitro models of the NVU to study ischemic events seen in the human brain. METHODS: We here describe the development of a human NVU on-a-chip model using a platform that allows culture of 40 chips in parallel. The model comprises a perfused vessel of primary human brain endothelial cells in co-culture with induced pluripotent stem cell derived astrocytes and neurons. Ischemic stroke was mimicked using a threefold approach that combines chemical hypoxia, hypoglycemia, and halted perfusion. RESULTS: Immunofluorescent staining confirmed expression of endothelial adherens and tight junction proteins, as well as astrocytic and neuronal markers. In addition, the model expresses relevant brain endothelial transporters and shows spontaneous neuronal firing. The NVU on-a-chip model demonstrates tight barrier function, evidenced by retention of small molecule sodium fluorescein in its lumen. Exposure to the toxic compound staurosporine disrupted the endothelial barrier, causing reduced transepithelial electrical resistance and increased permeability to sodium fluorescein. Under stroke mimicking conditions, brain endothelial cells showed strongly reduced barrier function (35-fold higher apparent permeability) and 7.3-fold decreased mitochondrial potential. Furthermore, levels of adenosine triphosphate were significantly reduced on both the blood- and the brain side of the model (4.8-fold and 11.7-fold reduction, respectively). CONCLUSIONS: The NVU on-a-chip model presented here can be used for fundamental studies of NVU function in stroke and other neurological diseases and for investigation of potential restorative therapies to fight neurological disorders. Due to the platform's relatively high throughput and compatibility with automation, the model holds potential for drug compound screening.


Assuntos
Astrócitos , Células Endoteliais , Células-Tronco Pluripotentes Induzidas , AVC Isquêmico , Dispositivos Lab-On-A-Chip , Modelos Biológicos , Neurônios , Acoplamento Neurovascular , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA