1.
Arthroscopy ; 39(3): 887-901, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36574536

RESUMO

PURPOSE: To perform a systematic review of the literature and evaluate the return to play (RTP) time frame after a concussion diagnosis. Our secondary purpose was to analyze and compare different prognostic variables affecting concussions, time to return to school, time to symptom resolution of concussive symptoms, and time each patient spent in the RTP protocol. METHODS: A PubMed, Scopus, Medline, Embase, and Cochrane Library database literature review was performed in August 2022. The studies needed to report, in days, the length of time a patient/athlete was removed from play due to concussion management. The Risk of Bias in Non-Randomized Studies of Interventions tool was used for risk of bias for each study, and Methodological Index for Non-Randomized Studies criteria were used for quality assessment. RESULTS: There were 65 studies included in the systematic review and a total of 21,966 patients evaluated. The RTP time intervals ranged from 1 to 1,820 days, with 80.7% of the median RTP time frames for each study within 21 days. Preconcussion risk factors for prolonged RTP included female sex, younger age, presence of psychiatric disorders, and history of previous concussion. Postconcussion risk factors included severe symptom scores at initial clinic visit, loss of consciousness, nonelite athletes, and delayed removal from competition. The most common sports resulting in concussion were contact sports, most commonly football and soccer. Median time to return to school was 3 to 23 days. Median time to symptom resolution ranged from 2 to 11 days. Median time in RTP protocol was 1 to 6 days. CONCLUSIONS: Median time to return to sports after concussion is within 21 days in 80% of published studies. LEVEL OF EVIDENCE: IV, systematic review of Level I to IV studies.


Assuntos
Concussão Encefálica , Futebol Americano , Volta ao Esporte , Futebol , Feminino , Humanos , Atletas/psicologia , Traumatismos em Atletas/diagnóstico , Concussão Encefálica/diagnóstico , Concussão Encefálica/etiologia , Concussão Encefálica/psicologia
2.
Arch Orthop Trauma Surg ; 142(3): 401-408, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33123810

RESUMO

INTRODUCTION: Management of humerus nonunions with previously failed fixation presents a complex problem. There are multiple revision fixation strategies, of which compression plating is a mainstay. The aim of this study was to assess the results of open reduction and direct compression plating without the need for autograft or allograft in the setting of revision humerus open reduction internal fixation. METHODS: This study is a retrospective analysis of 19 patients treated between 2008 and 2017 for humerus nonunions following failed fixation who were treated by a single surgeon using direct compression plating with bone graft substitutes. Patients were treated with neurolysis of the radial nerve, hardware removal, debridement of the nonunion site with shortening osteotomies, compression plating, and augmentation with bone graft substitutes. All patients were followed until radiographic and clinical union. RESULTS: Nineteen patients were identified for the study and 17 had adequate follow-up for final analysis. Humeral union was achieved in 16/17 (94.1%) patients with a mean time to union of 23 weeks. Two patients required a repeat compression plating with bone graft substitute to achieve union. The one patient with a nonunion radiographically reported minimal clinical symptoms and opted for no revision surgery. An association with the index procedure was seen, as three out of four of the patients who experienced radial nerve palsies after their index procedure subsequently experienced a radial nerve palsy after the procedure to repair their nonunion. All patient's all experienced a return of function in their radial nerve either back to baseline or improved from before the revision nonunion surgery. CONCLUSION: The use of humeral shortening osteotomy and compression plating without autograft or allograft is a viable option for management of humeral nonunions which avoids the morbidity associated with autograft harvest. The patients with radial nerve palsy after the index procedure are likely to have a transient radial nerve palsy as well after the revision surgery necessitating proper informed consent prior to the operation.


Assuntos
Fraturas não Consolidadas , Fraturas do Úmero , Placas Ósseas , Transplante Ósseo , Fixação Interna de Fraturas , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38788054

RESUMO

CASE: A 34-year-old man was a restrained passenger involved in a high-speed rollover motor vehicle crash. The patient sustained a type 5 AC joint separation, severely comminuted intra-articular glenoid fracture with extension to the coracoid process base, displaced open scapular body fracture, a posterior shoulder dislocation of the glenohumeral joint, and a 2-part proximal humerus fracture. CONCLUSION: To our knowledge, this is the first report describing this injury pattern involving the superior shoulder suspensory complex with an associated open proximal humerus fracture-dislocation.


Assuntos
Luxação do Ombro , Fraturas do Ombro , Humanos , Masculino , Adulto , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Luxação do Ombro/diagnóstico por imagem , Fraturas Expostas/cirurgia , Fraturas Expostas/diagnóstico por imagem , Acidentes de Trânsito , Fraturas Cominutivas/cirurgia , Fraturas Cominutivas/diagnóstico por imagem
4.
J Spine Surg ; 9(4): 434-443, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-38196725

RESUMO

Background: Traditional pedicle screws (TPSs) and cortical based trajectory pedicle screws each apply stability with fusions of the lumbar spine and have shown good success. However, the technical considerations of each technique imply complications of loosening and failure that either technique is uniquely prone to having. The current study proposes a new pedicle screw technique through the articular surface of the vertebral superior facet. It is hypothesized that this path will allow utilization of a larger screw that rivals that of the TPS technique, while also maintaining the high-density bone encountered in the cortical based trajectory technique. Methods: Retrospective review of 50 consecutive trauma patients that underwent lumbar computed tomography (CT) scans at a Level 1 Trauma Center in the age range 18-45. These scans were uploaded to Brainlab software for ideal starting point and trajectory mapping of pedicle screws coursing through each superior facet and pedicle of vertebral levels L1-S1 without cortical breach. Satisfactory pedicle screw variables consisted of a medial angle <10 degrees, screw length at least 30 mm, screw width at least 5.0 mm, and starting point measurements such as distance to the inferior articular surface and distance to the lateral articular surface. Results: A total of 600 virtual pedicle screws were placed, in which 525 were satisfactory and measured with the above variables. The pedicle widths were shown to significantly widen with lower-level vertebra in the lumbar spine. Approximately 72% of unsuccessful pedicle screws were placed in levels L1 and L2 allowing wider pedicle screws to be placed more further down the vertebral column. Conclusions: The articular surface technique (AST) for pedicle screw placement is a viable alternative in lumbar spinal fusions that offers decreased soft tissue dissection. However, the technique is likely better suited for lower lumbar fusions in L3 to S1.

5.
Arthrosc Tech ; 12(9): e1479-e1485, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37780666

RESUMO

The hip capsule has been recognized as a vital structure in the stability and proper function of the hip. Preserving its integrity during arthroscopic surgery is one of the utmost important principles in hip preservation surgery. When capsular deficiency is present, capsular reconstruction may be indicated to restore stability and proper hip mechanics. In this technical note, we introduce a simple and reproducible shuttle method technique for hip capsular reconstruction using a dermal allograft.

6.
Arthrosc Tech ; 12(8): e1383-e1389, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37654867

RESUMO

Tibial anterolateral rotary instability associated with anterior cruciate ligament (ACL) tears is a well-documented and difficult problem with a long history of solutions. The lateral extra-articular tenodesis (LET) has undergone multiple refinements in technique, largely focusing on the femoral site insertion using either an interference screw versus a staple for adequate fixation. In this article, we present an improved technique using a suture anchor as an alternative to a staple or an interference screw with secure fixation to insert the LET graft onto the femur. This technique diminishes the chance of ACL tunnel-LET drilling convergence, minimizes the footprint required for adequate graft fixation, and allows the surgeon to dial in the correct tension necessary for adequate augmentation of an ACL reconstruction.

7.
Clin Med Insights Case Rep ; 15: 11795476221111771, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35991755

RESUMO

Background: Osteochondromas are a relatively common primary bone tumor, which may share common clinical features with Osgood-Schlatter disease (OSD). A limited number of cases have described tumors misdiagnosed as OSD. Case Presentation: We report the case of an 11-year-old male with a sessile osteochondroma of the tibial tubercle and concomitant involvement of the distal extension and attachment of the patellar tendon into the tibial periosteum. A prior diagnosis OSD had been made. The lesion was resected and repair of the extensor mechanism was required at the time of surgery. The patient was followed for 20 months postoperatively and had restoration of knee function with minimal pain, as demonstrated by a PEDI-IKDC score of 94.6 at 19-month. Conclusion: This is a rarely reported case of benign tumor masquerading as OSD requiring excisional biopsy with extensor mechanism repair.

8.
Cureus ; 14(9): e29554, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36312639

RESUMO

Introduction Femoral torsion is an important anatomical consideration of the hip that has major implications on the natural motion of the hip joint. Similarly, it affects pathologic conditions of the hip, including femoroacetabular impingement, dysplasia, and/or microinstability. Femoral torsion is typically measured on two-dimensional (2D) axial CT cuts by creating the angle between the femoral neck and the posterior aspect of the ipsilateral femoral condyles. Position of the leg during imaging may affect 2D measurements. Three-dimensional (3D) analysis of a hip CT with inclusion of femoral alignment may portray the anatomy of the hip more accurately as compared to a 2D slice-based analysis of a hip CT scan. It is thought that femoral torsion measured using this system could be a more accurate and reliable means of measurement. The primary purpose of this study is to assess the differences in measuring femoral torsion with 3D modeling and analysis compared to the standard 2D slice-based approach on a CT scan. Secondarily, we attempt to determine how the passive range of motion of the hip correlates with femoral torsion measured using the 3D model versus the 2D model. Methods In a prospective cohort study of 20 patients, femoral torsion was assessed using both 2D analysis and 3D analysis. The differences between these measurements on each of the imaging modalities were compared. Additionally, each patient had the passive range of motion of their hip measured with a goniometer. The amount of internal and external rotation was measured with the hip in a neutral position and with the hip flexed to 90°. Acetabular version, combined version, and alpha angle were added to multivariate regression analysis to evaluate their effect versus femoral torsion alone. Results Femoral antetorsion measured using the standard 2D slice-based approach on CT scan was 22.1° (SD: 11.1°), which was higher (p<0.001) than that using 3D analysis (8.25°; SD: 10.5°). There was a strong correlation between femoral torsion measurements using 3D analysis and 2D analysis (R=0.91). Based on 3D analysis, there was a moderate correlation between femoral torsion and passive hip external rotation measured with the hip flexed to 90° (R=0.65, p<0.002) and with the hip in a neutral position (R=0.58, p<0.007). Conclusion There was a significant difference between femoral torsion measurements using the 3D analysis, which showed approximately 14° of less antetorsion on average. Additionally, rotation of the hip and femoral torsion was correlated to higher levels of antetorsion associated with more internal rotation of the hip.