RESUMO
INTRODUCTION: Pacemaker implantation can be challenging in patients with congenital heart disease. METHODS AND RESULTS: In a patient with Ebstein disease and symptomatic sinus node dysfunction, despite multiple attempts, the Micra® pacemaker could not be implanted in the severely dilated right ventricle. In that context, and after iodine injection to confirm the appropriate location, the Micra® pacemaker was successfully implanted in the right appendage at the first attempt. CONCLUSION: Despite the recent development of dedicated dual-chamber leadless pacemaker, to the best of our knowledge, this case is the first off-label Micra® implantation in a right appendage.
Assuntos
Apêndice Atrial , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/fisiopatologia , Síndrome do Nó Sinusal/diagnóstico , Anomalia de Ebstein/cirurgia , Anomalia de Ebstein/fisiopatologia , Resultado do Tratamento , Masculino , Desenho de EquipamentoRESUMO
AIMS: The implantable cardioverter defibrillator (ICD) has been increasingly used in children. Both epicardial and transvenous approaches are used, with controversy regarding the best option with no specific recommendations. We aimed to compare outcomes associated with epicardial vs. transvenous ICDs in children. METHODS AND RESULTS: Data were analysed from a retrospective study including all patients <18-year-old implanted with an ICD in a tertiary centre from 2003 to 2021. Outcomes were compared between epicardial and transvenous ICDs. A total of 122 children with an ICD (mean age 11.5 ± 3.8 years, 57.4% males) were enrolled, with 84 (64.1%) epicardial ICDs and 38 (29.0%) transvenous ICDs. Early (<30 days) ICD-related complications were reported in 17 (20.2%) patients with an epicardial ICD vs. 0 (0.0%) with a transvenous ICD (P = 0.002). Over a mean follow-up of 4.8 ± 4.0 years, 25 (29.8%) patients with an epicardial ICD and 9 (23.7%) patients with a transvenous ICD experienced at least one late ICD-related complication [hazard ratio (HR) 1.8, 95% confidence interval (CI) 0.8-4.0]. Implantable cardioverter defibrillator lead dysfunction occurred in 19 (22.6%) patients with an epicardial ICD vs. 3 (7.9%) with a transvenous ICD (HR 5.7, 95% CI 1.3-24.5) and was associated with a higher incidence of ICD-related reintervention (HR 3.0, 95% CI 1.3-7.0). After considering potential confounders, especially age and weight at implantation, this association was no longer significant (P = 0.112). The freedom from ICD lead dysfunction was greater in patients with pleural coils than in those with epicardial coils (HR 0.38, 95% CI 0.15-0.96). CONCLUSION: In children, after a consideration of patient characteristics at implantation, the burden of complications and ICD lead dysfunction appears to be similar in patients with epicardial and transvenous devices. Pleural coils seem to be associated with better outcomes than epicardial coils in this population. CLINICAL TRIAL REGISTRATION: NCT05349162.
Assuntos
Desfibriladores Implantáveis , Adolescente , Criança , Feminino , Humanos , Masculino , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
AIMS: The incidence of atrial tachyarrhythmias is high in patients with atrioventricular septal defect (AVSD). No specific data on catheter ablation have been reported so far in this population. We aimed to describe the main mechanisms of atrial tachyarrhythmias in patients with AVSD and to analyse outcomes after catheter ablation. METHODS AND RESULTS: This observational multi-centric cohort study enrolled all patients with AVSD referred for catheter ablation of an atrial tachyarrhythmia at six tertiary centres from 2004 to 2022. The mechanisms of the different tachyarrhythmias targeted were described and outcomes were analysed. Overall, 56 patients (38.1 ± 17.4 years, 55.4% females) were included. A total of 87 atrial tachyarrhythmias were targeted (mean number of 1.6 per patient). Regarding main circuits involved, a cavo-annular isthmus-dependent intra-atrial re-entrant tachycardia (IART) was observed in 41 (73.2%) patients and an IART involving the right lateral atriotomy in 10 (17.9%) patients. Other tachyarrhythmias with heterogeneous circuits were observed in 13 (23.2%) patients including 11 left-sided and 4 right-sided tachyarrhythmias. Overall, an acute success was achieved in 54 (96.4%) patients, and no complication was reported. During a mean follow-up of 2.8 ± 3.8 years, 22 (39.3%) patients had at least one recurrence. Freedom from atrial tachyarrhythmia recurrences was 77.5% at 1 year. Among 15 (26.8%) patients who underwent repeated ablation procedures, heterogeneous circuits including bi-atrial and left-sided tachyarrhythmias were more frequent. CONCLUSION: In patients with AVSD, most circuits involve the cavo-annular isthmus, but complex mechanisms are frequently encountered in patients with repeated procedures. The acute success rate is excellent, although recurrences remain common during follow-up.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos de Coortes , Taquicardia/diagnóstico , Taquicardia/cirurgia , Ablação por Cateter/efeitos adversos , RecidivaRESUMO
AIMS: Electrophysiology (EP) is a growing field in cardiology, with an increasing involvement of young people. Nevertheless, concerns about radiation exposure and its impact on reproduction and pregnancy may discourage the choice of an EP career. The study is aimed at investigating the level of awareness and main sources of concern about the effects of radiation on reproductive potential and pregnancy, exploring the safety measures adopted in different EP labs, and verifying the adherence to the current guidelines. METHODS AND RESULTS: An online survey was conducted using the European Heart Rhythm Association (EHRA) infrastructure from April to June 2022. A total of 252 EP personnel (42% women) participated, from 50 countries and different professional roles. Most participants expressed concerns regarding the effects of radiation on reproductive capacity (67.1%) and offspring diseases (68.2%). Only 37.9% of participants were aware of the EHRA 2017 consensus document about occupational radiation exposure. Most participants (80.9%) considered that occupational radiation during pregnancy is not safe. EP female staff were not allowed to work in the EP lab during pregnancy in 48.1% of cases. Zero-fluoroscopy was the preferred choice to continue working in the EP lab during pregnancy. CONCLUSION: EP staff, including both men and women, have concerns about the effects of radiation on reproductive capacity. Despite the recommendations issued by international bodies, implementation of the policies regarding pregnancy and occupational radiation exposure is heterogeneous. Zero-fluoroscopy is the preferred approach to ensure safety during pregnancy in the EP lab.
Assuntos
Exposição Ocupacional , Exposição à Radiação , Lesões por Radiação , Masculino , Gravidez , Feminino , Humanos , Adolescente , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Inquéritos e Questionários , Reprodução , Eletrofisiologia Cardíaca , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Doses de RadiaçãoRESUMO
AIMS: The epidemiology of sudden cardiac death (SCD) after heart transplantation (HTx) remains imprecisely described. We aimed to assess the incidence and determinants of SCD in a large cohort of HTx recipients, compared with the general population. METHODS AND RESULTS: Consecutive HTx recipients (n = 1246, 2 centres) transplanted between 2004 and 2016 were included. We prospectively assessed clinical, biological, pathologic, and functional parameters. SCD was centrally adjudicated. We compared the SCD incidence beyond the first year post-transplant in this cohort with that observed in the general population of the same geographic area (registry carried out by the same group of investigators; n = 19 706 SCD). We performed a competing risk multivariate Cox model to identify variables associated with SCD. The annual incidence of SCD was 12.5 per 1,000 person-years [95% confidence interval (CI), 9.7-15.9] in the HTx recipients cohort compared with 0.54 per 1,000 person-years (95% CI, 0.53-0.55) in the general population (P < 0.001). The risk of SCD was markedly elevated among the youngest HTx recipients with standardized mortality ratios for SCD up to 837 for recipients ≤30 years. Beyond the first year, SCD was the leading cause of death. Five variables were independently associated with SCD: older donor age (P = 0.003), younger recipient age (P = 0.001) and ethnicity (P = 0.034), pre-existing donor-specific antibodies (P = 0.009), and last left ventricular ejection fraction (P = 0.048). CONCLUSION: HTx recipients, particularly the youngest, were at very high risk of SCD compared with the general population. The consideration of specific risk factors may help identify high-risk subgroups.
Assuntos
Transplante de Coração , Função Ventricular Esquerda , Humanos , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Transplante de Coração/efeitos adversos , Fatores de RiscoRESUMO
Emerging evidence suggests that atrial fibrillation (AF) may be associated with an increased risk of sudden cardiac death (SCD). However, AF shares risk factors with numerous cardiac conditions, including coronary heart disease and heart failure-the 2 most common substrates for SCD-making the AF-SCD relationship particularly challenging to address. A careful consideration of confounding factors is essential, since interventions for AF will be effective in reducing SCD only if there is a causal association between these 2 conditions. In this translational review, we detail the plausible underlying pathophysiological mechanisms through which AF may promote or lead to SCD, as well as the existing epidemiological evidence supporting an association between AF and SCD. While the role of AF in predicting SCD in the general population appears limited and not established, AF might be integrated to improve risk stratification in some specific phenotypes. Optimal AF management, including that of its associated conditions, appears to be of interest to prevent AF-related SCD, especially because the AF-SCD relationship is in part driven by heart failure.
Assuntos
Fibrilação Atrial/etiologia , Morte Súbita Cardíaca/etiologia , Fibrilação Atrial/epidemiologia , Morte Súbita Cardíaca/epidemiologia , HumanosRESUMO
BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.
Assuntos
Desfibriladores Implantáveis/tendências , Tetralogia de Fallot/epidemiologia , Tetralogia de Fallot/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Sistema de RegistrosRESUMO
Catheter ablation for atrial fibrillation (AF) has become one of the most common procedures in the electrophysiology lab with rapidly increasing volumes. Peri-procedural anaesthesia for AF ablation varies between centres, from general anaesthesia to deep or conscious sedation. The aim of this survey was to assess current sedation practices for AF ablation worldwide and its evolution over the last decade. Centres regularly performing AF ablation responded to an online survey. A total of 297 centres participated in the survey. Overall, the median (interquartile range) number of AF ablation procedures increased from 91 (43-200) to 200 (74-350) per year (P < 0.001) between 2010 and 2019. The proportion of cryoablation also increased from 17.0% to 33.2% (P < 0.001). In 2019, the most used sedation technique was general anaesthesia (40.5%), followed by conscious sedation (32.0%) and deep sedation (27.5%). Between 2010 and 2019, the proportion of procedures performed under general anaesthesia (+4.4%; P = 0.02) and deep sedation (+4.8%; P < 0.01) increased, whereas the use of conscious sedation decreased (-9.2%; P < 0.001). The most commonly used hypnotic drugs were propofol and midazolam, whereas the most commonly used opioid drugs were remifentanyl and fentanyl. This worldwide survey shows that the number of AF ablation procedures has more than doubled over the last decade and general anaesthesia remains most commonly used. Studies comparing outcomes between different sedation strategies are needed to guide optimal decision-making.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Propofol , Anestesia Geral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Midazolam , Resultado do TratamentoRESUMO
AIMS: Atrial fibrillation (AF) catheter ablation is a common procedure requiring in most cases the use of fluoroscopy. We aimed to evaluate the factors associated with a lower dose of fluoroscopy used during AF ablation with cryoballoon or radiofrequency. METHODS: In this prospective European registry, centers were requested to provide procedural characteristics of consecutive AF ablation cases. Lower doses of fluoroscopy were defined as those with dose-area-product (DAP) under the median dose used in the radiofrequency and the cryoballoon ablation groups. RESULTS: A total of 638 AF ablation procedures were collected (n = 492 for radiofrequency and n = 146 for cryoballoon ablation groups) in 25 centers. The median [IQR] DAP were 926 [349;2092] and 1516 [418;3408] cGy*cm2 in the radiofrequency and cryoballoon groups, respectively. Main factors associated with lower DAP in cryoballoon ablation group were electrophysiology dedicated laboratory (OR 6.04, 95%CI 1.16-31.54; P = .03) and frequent dosimetry report (OR 21.39, 95%CI 5.43-98.54; P = .03). Main factors associated with lower DAP in the radiofrequency ablation group were the use of a chest dosimeter (OR 12.57, 95% CI 2.88-54.90; P = .01), biplane X-ray equipment (OR 3.12, 95%CI 1.89-5.16; P < .01), university hospital (OR 2.10, 95%CI 1.35-3.25; P = .01), electrophysiology dedicated laboratory (OR 2.45, 95%CI 1.48-4.05; P < .01) and use of contact force enabled catheter (OR 22.60, 95%CI 6.82-74.88; P < .01). CONCLUSION: This real-life study of fluoroscopy use during AF ablation provides new data about current practices across European countries. Technological advances and quality of the fluoroscopic environment were the main factors associated with lower radiation dose during AF ablation.
Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Doses de Radiação , Adulto , Idoso , Europa (Continente) , Feminino , Fluoroscopia , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de RegistrosRESUMO
AIMS: While pulmonary embolism (PE) appears to be a major issue in COVID-19, data remain sparse. We aimed to describe the risk factors and baseline characteristics of patients with PE in a cohort of COVID-19 patients. METHODS AND RESULTS: In a retrospective multicentre observational study, we included consecutive patients hospitalized for COVID-19. Patients without computed tomography pulmonary angiography (CTPA)-proven PE diagnosis and those who were directly admitted to an intensive care unit (ICU) were excluded. Among 1240 patients (58.1% men, mean age 64 ± 17 years), 103 (8.3%) patients had PE confirmed by CTPA. The ICU transfer and mechanical ventilation were significantly higher in the PE group (for both P < 0.001). In an univariable analysis, traditional venous thrombo-embolic risk factors were not associated with PE (P > 0.05), while patients under therapeutic dose anticoagulation before hospitalization or prophylactic dose anticoagulation introduced during hospitalization had lower PE occurrence [odds ratio (OR) 0.40, 95% confidence interval (CI) 0.14-0.91, P = 0.04; and OR 0.11, 95% CI 0.06-0.18, P < 0.001, respectively]. In a multivariable analysis, the following variables, also statistically significant in univariable analysis, were associated with PE: male gender (OR 1.03, 95% CI 1.003-1.069, P = 0.04), anticoagulation with a prophylactic dose (OR 0.83, 95% CI 0.79-0.85, P < 0.001) or a therapeutic dose (OR 0.87, 95% CI 0.82-0.92, P < 0.001), C-reactive protein (OR 1.03, 95% CI 1.01-1.04, P = 0.001), and time from symptom onset to hospitalization (OR 1.02, 95% CI 1.006-1.038, P = 0.002). CONCLUSION: PE risk factors in the COVID-19 context do not include traditional thrombo-embolic risk factors but rather independent clinical and biological findings at admission, including a major contribution to inflammation.
Assuntos
Betacoronavirus , Infecções por Coronavirus/complicações , Hospitalização/tendências , Pandemias , Pneumonia Viral/complicações , Embolia Pulmonar/etiologia , COVID-19 , Angiografia por Tomografia Computadorizada/métodos , Infecções por Coronavirus/epidemiologia , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/epidemiologia , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/epidemiologia , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Taxa de Sobrevida/tendênciasRESUMO
The important increase in life expectancy of adult patients with congenital heart disease (ACHD) has generated new challenges, including arrhythmias that represent one of the main late complications. Reentrant atrial arrhythmias are by far the main mechanism encountered, and catheter ablation has been now presented as a first-line therapy in this patient population. The number of procedures is expected to continuously increase year after year. The heterogeneity and complexity of phenotypes encountered require these cases to be performed by highly experienced operators, in specialized centers with multidisciplinary competencies. A thorough knowledge and understanding of anatomic specificities, vascular access issues, and main circuits encountered according to underlying phenotype is essential. Acute success rates have significantly improved and are now excellent, but recurrences remain a common issue, with different mechanisms or circuits frequently encountered. Observational data have suggested the interest of systematically targeting all inducible atrial arrhythmias, whether previously documented or not, and a lot of hope and research is based on the prediction of arrhythmia substrate before arrhythmia development by imaging or electroanatomic mapping to deliver a prophylactic patient tailored ablation approach. In this review, we summarize those different points in the most common or distinctive defects to offer a didactic overview of atrial flutter catheter ablation in ACHD patients.
RESUMO
Recently, four SCN5A mutations have been associated with Multifocal Ectopic Purkinje-related Premature Contractions (MEPPC), a rare cardiac syndrome combining polymorphic ventricular arrhythmia with dilated cardiomyopathy (DCM). Here, we identified a novel heterozygous mutation in SCN5A (c.611C>A, pAla204Glu) in a young woman presenting with polymorphic premature ventricular contractions (PVCs) and DCM. After failure of antiarrhythmic drugs and an attempt of radiofrequency catheter ablation showing three exit-sites of PVCs, all with presystolic Purkinje potentials, a treatment by hydroquinidine was tried, leading to an immediate and spectacular disappearance of all PVCs and normalization of cardiac function. Electrophysiological studies showed that Nav 1.5-A204E mutant channels exhibited a significant leftward shift of 8 mV of the activation curve, leading to a larger hyperpolarized window current when compared to wild-type. Action potential modeling using Purkinje fiber and ventricular cell models predicted an arrhythmogenic effect predominant in Purkinje fibers for the A204E mutation. Comparison with other MEPPC-associated Nav 1.5 mutations revealed a common electrophysiological pattern of abnormal voltage-dependence of activation leading to a larger hyperpolarized window current as a shared biophysical mechanism of this syndrome. These features of the mutant sodium channels are likely to be responsible for the hyperexcitability of the fascicular-Purkinje system observed in patients with MEPPC.
Assuntos
Estudos de Associação Genética , Predisposição Genética para Doença , Ramos Subendocárdicos/metabolismo , Ramos Subendocárdicos/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Adolescente , Alelos , Sequência de Bases , Análise Mutacional de DNA , Eletrocardiografia , Feminino , Mutação com Ganho de Função , Estudos de Associação Genética/métodos , Testes Genéticos , Genótipo , Humanos , Imageamento por Ressonância Magnética , Canal de Sódio Disparado por Voltagem NAV1.5 , Fenótipo , Complexos Ventriculares Prematuros/tratamento farmacológicoRESUMO
INTRODUCTION: Catheter ablation (CA) of atrial tachyarrhythmias (ATs) in patients with complex congenital heart disease (CHD) often requires technically challenging transbaffle or transconduit puncture. The aim was to assess the feasibility and safety of transbaffle/transconduit puncture based on computed tomography (CT) three-dimensional (3D) reconstruction merged with electro-anatomical mapping (EAM) without per-procedure echocardiographic guidance. METHODS AND RESULTS: We included 18 consecutive CHD patients in two centers who had atrial-switch or Fontan surgery and underwent CA of AT by an antegrade approach requiring intracardiac puncture. Twelve patients with atrial-switch surgery and six patients with extracardiac Fontan surgery were referred for CA of AT. Cardiac CT with 3D reconstruction was performed before the procedure. The 3D volume of the systemic venous atrium or extracardiac conduit acquired by EAM was merged with the corresponding CT 3D reconstruction. The ablation catheter was positioned at the optimal puncture site. Under fluoroscopic guidance, the needle was positioned next to the ablation and the puncture was performed. Balloon expansion of the puncture site was performed in every case of transconduit puncture and in two (17%) cases of transbaffle puncture. Overall, 17 intra-atrial reentrant tachycarrythmias and 9 focal ATs were successfully ablated, with no acute complications. The median time to access the pulmonary atrium was 78.5 minutes (range, 55-185) and total median fluoroscopy time was 23 minutes (range, 7-53). CONCLUSIONS: Transbaffle and transconduit punctures can be performed safely in CHD patients by using a simple technique relying on CT 3D reconstruction and EAM.
Assuntos
Ablação por Cateter , Técnica de Fontan , Cardiopatias Congênitas , Ablação por Cateter/efeitos adversos , Ecocardiografia , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Punções , Resultado do TratamentoRESUMO
Electrical injuries are a commonly encountered hazard in both the home and workplace. However, clinicians are often uncomfortable when faced with the patient who presents with an electric shock due to sparse literature and lack of systematic recommendations on this topic. Electrical injuries can range from minor skin burns to life threatening internal organ damage. A thorough clinical assessment to ascertain the path of current through the body and possible internal injury is essential. The main concern in an apparently stable individual after an electric shock is the potential for delayed occurrence of cardiac arrhythmias which will require monitoring in the intensive care setting. While it may be reasonable to discharge home from the emergency room selected patients with low voltage injuries, absence of syncope and a normal ECG, others may require monitoring for at least 24 h. Public education and increasing workplace as well as home safety measures are key steps in prevention. The present review summarizes current knowledge in pathophysiology, manifestations and management of electrical injuries, with specific focus on cardiac effects.
Assuntos
Traumatismos por Eletricidade/terapia , Traumatismos Cardíacos/terapia , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/fisiopatologia , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/fisiopatologia , HumanosRESUMO
Aims: Recent studies have shown that in more than half of apparently unexplained sudden cardiac arrests (SCA), a specific aetiology can be unmasked by a careful evaluation. The characteristics and the extent to which such cases undergo a systematic thorough investigation in real-life practice are unknown. Methods and results: Data were analysed from an ongoing study, collecting all cases of out-of-hospital cardiac arrest in Paris area. Investigations performed during the index hospitalization or planned after discharge were gathered to evaluate the completeness of assessment of unexplained SCA. Between 2011 and 2016, among the 18 622 out-of-hospital cardiac arrests, 717 survivors (at hospital discharge) fulfilled the definition of cardiac SCA. Of those, 88 (12.3%) remained unexplained after electrocardiogram, echocardiography, and coronary angiography. Cardiac magnetic resonance imaging yielded the diagnosis in 25 (3.5%) cases, other investigations accounted for 14 (2.4%) additional diagnoses, and 49 (6.8%) patients were labelled as idiopathic ventricular fibrillation (IVF) (48.7 ± 15 years, 69.4% male). Among those labelled IVF, only 8 (16.3%) cases benefited from a complete workup (including pharmacological testing). Younger patients [odds ratio (OR) 6.00, 95% confidence interval (CI) 1.80-22.26] and those admitted to university centres (OR 3.60, 95% CI 1.12-12.45) were more thoroughly investigated. Genetic testing and family screening were initiated in only 9 (18.4%) and 12 (24.5%) cases, respectively. Conclusion: Our findings suggest that complete investigations are carried out in a very low proportion of unexplained SCA. Standardized, systematic approaches need to be implemented to ensure that opportunities for specific therapies and preventive strategies (including relatives) are not missed.
Assuntos
Morte Súbita Cardíaca/etiologia , Parada Cardíaca Extra-Hospitalar/etiologia , Fibrilação Ventricular/diagnóstico , Adulto , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Doença do Sistema de Condução Cardíaco/complicações , Doença do Sistema de Condução Cardíaco/diagnóstico , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Ecocardiografia , Eletrocardiografia , Família , Feminino , Testes Genéticos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Sobreviventes , Fibrilação Ventricular/complicações , Fibrilação Ventricular/genéticaRESUMO
We present a case of sudden cardiac arrest 7 hours after radiofrequency ablation of the atrioventricular junction for symptomatic permanent atrial fibrillation unresponsive to medical therapy. The Holter monitoring revealed a progressive increasing of QT interval after the procedure, highlighting the repolarization instability after acute changes in heart rates associated with modification of ventricular activation, leading to occurrence of short coupling interval ventricular extra beats and finally to a "torsade de pointes." This illustration underlines the need to program a relatively rapid ventricular rate first weeks after junction ablation, especially in case of rapid ventricular rate prior to the procedure, as well as the role of continuous ECG and QT interval monitoring during hospital stay.