Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Echocardiography ; 39(12): 1571-1580, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36376261

RESUMO

BACKGROUND: The success of transcatheter aortic valve replacement (TAVR) in native aortic regurgitation (AR) is limited by the absence of calcified anchoring structures. We sought to evaluate transfemoral TAVR in patients with native AR using a novel aortic root imaging classification. METHODS: From March to November 2021, 81 patients with severe AR were prospectively enrolled in 2 cardiac centers in China. All were evaluated using multidetector computed tomography (MDCT) and classified into 4 anatomic types in reference to transcatheter heart valve (THV) anchoring: Type 1: anchoring at the left ventricular outflow tract (LVOT), annulus, and ascending aorta (AA); Type 2: anchoring at the annulus and AA; Type 3: anchoring at the annulus and LVOT; and Type 4: anchoring at only 1 level or none at all. Based on the dual-anchoring strategy, patients with Types 1-3 were considered TAVR candidates. Procedural and 30-day outcomes were assessed according to Valve Academic Research Consortium-3 definitions. RESULTS: TAVR was performed in 32 (39.5%) patients (71.9 ± 8.0 years of age, 71.9% were male) using 2 self-expanding THVs. Types 1, 2, and 3 comprised 13 (40.6%), 11 (34.4%), and 8 (25.0%) cases, respectively. The procedural and device success rates were 100% and 93.8%, respectively, with 2 THV migration. Eight patients (25.0%) required a permanent pacemaker, and 2 (6.3%) developed moderate paravalvular leaks. No deaths or other major complications occurred during the study. CONCLUSIONS: The novel anatomic classification and dual-anchoring strategy were associated with a high procedural success rate with favorable short-term safety and clinical outcomes.


Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Feminino , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , China
2.
J Clin Med ; 12(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36769804

RESUMO

INTRODUCTION: Chronic severe aortic regurgitation (AR) has a poor long-term prognosis, especially among old-age patients. Considering their advancing age, the surgical approach of aortic valve replacement may not always be the best alternative modality of treatment in such patients. Therefore, this study's primary goal was to provide an initial summary of the medium- and short-term clinical effectiveness of transcatheter aortic valve replacement (TAVR) guided by accurate multi-detector computed tomography (MDCT) measurements in patients with severe and chronic AR, especially in elderly patients. METHODS: The study enrolled retrospectively and prospectively patients diagnosed with severe AR who eventually underwent TAVR procedure from January 2019 to September 2022 at Fuwai cardiovascular Hospital, Beijing. Baseline information, MDCT measurements, anatomical classification, perioperative, and 1-year follow-up outcomes were collected and analyzed. Based on a novel anatomical categorization and dual anchoring theory, patients were divided into four categories according to the level of anchoring area. Type 1, 2, and 3 patients (with at least two anchoring regions) will receive TAVR with a transcatheter heart valve (THV), but Type 4 patients (with zero or one anchoring location) will be deemed unsuitable for TAVR and will instead receive medical care (retrospectively enrolled patients who already underwent TAVR are an exception). RESULTS: The mean age of the 37 patients with severe chronic AR was 73.1 ± 8.7 years, and 23 patients (62.2%) were male. The American Association of Thoracic Surgeons' score was 8.6 ± 2.1%. The MDCT anatomical classification included 17 cases of type 1 (45.9%), 3 cases of type 2 (8.1%), 13 cases of type 3 (35.1%), and 4 cases of Type 4 (10.8%). The VitaFlow valve (MicroPort, Shanghai, China) was implanted in 19 patients (51.3%), while the Venus A valve (Venus MedTech, Hangzhou, China) was implanted in 18 patients (48.6%). Immediate TAVR procedural and device success rates were 86.5% and 67.6%, respectively, while eight cases (21.6%) required THV-in-THV implantation, and nine cases (24.3%) required permanent pacemaker implantation. Univariate regression analysis revealed that the major factors affecting TAVR device failure were sinotubular junction diameter, THV type, and MDCT anatomical classification (p < 0.05). Compared with the baseline, the left ventricular ejection fraction gradually increased, while the left ventricular end-diastolic diameter remained small, and the N-terminal-pro hormone B-type natriuretic peptide level significantly decreased within one year. CONCLUSION: According to the results of our study, TAVR with a self-expanding THV is safe and feasible for patients with chronic severe AR, particularly for those who meet the criteria for the appropriate MDCT anatomical classification with intact dual aortic anchors, and it has a significant clinical effect for at least a year.

3.
Biosci Rep ; 40(9)2020 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-32893848

RESUMO

BACKGROUND: Galectin-3 may predict mortality for patients with aortic stenosis (AS) after transcatheter aortic valve replacement (TAVR). However, the results were inconsistent. We aimed to evaluate the association between baseline galectin and mortality after TAVR in a meta-analysis. METHODS: Related follow-up studies were obtained by systematic search of PubMed, Cochrane's Library, and Embase databases. Both the fixed- and the random-effect models were used for the meta-analysis. Subgroup analyses were performed to evaluate the influences of study characteristics on the outcome. RESULTS: Five prospective cohort studies with 854 patients were included, with a follow-up period between 1 and 1.9 years. Patients with higher baseline circulating galectin-3 had an increased risk of all-cause mortality after TAVR (random-effects model: risk ratio [RR]: 1.63, 95% confidence interval [CI]: 1.19-2.23, P=0.002; fixed-effects model: RR: 1.62, 95% CI: 1.19-2.20, P=0.002; I2 = 4%). Adjustment of estimated glomerular filtration rate (RR: 1.73, P=0.02) or B-type natriuretic peptide (BNP) or N-terminal pro-BNP (RR: 1.83, P=0.02) did not significantly affect the result. A trend of stronger association between higher baseline circulating galectin-3 and increased risk of all-cause mortality after TAVR was observed in studies with an enzyme-linked fluorescent assay (ELFA) (RR: 3.04, P=0.003) compared with those with an enzyme-linked immunosorbent assay (ELISA) (RR: 1.42, P=0.04; P for subgroup difference =0.06). CONCLUSION: Higher circulating galectin-3 before the procedure may predict all-cause mortality of AS patients after TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Galectinas/sangue , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Proteínas Sanguíneas , Causas de Morte , Humanos , Período Pós-Operatório , Período Pré-Operatório , Medição de Risco/métodos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
4.
Interv Cardiol Clin ; 7(3): 293-299, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29983142

RESUMO

Subclinical leaflet thrombosis has been increasingly recognized as a common imaging finding after surgical or transcatheter aortic valve replacement (TAVR) in recent studies. This finding has raised concerns over TAVR valve durability and debates on optimal postprocedural antithrombotic regime. Hypoattenuated leaflet thickening (HALT) and the associated reduced leaflet motion (RELM) were noted as computed tomography hallmarks of the phenomenon. The coexistence of HALT and significant RELM has been suggested as a threshold for reporting of subclinical leaflet thrombosis. This methodology may contribute to the standardization of reporting for research collaboration, hence the better understanding and management of this common yet largely unknown phenomenon.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/etiologia , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/patologia , Humanos , Falha de Prótese , Trombose/diagnóstico por imagem , Trombose/patologia , Tempo para o Tratamento , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA