Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Breast Cancer Res Treat ; 162(3): 479-488, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28176175

RESUMO

PURPOSE: This Phase I, multicenter, randomized study (ClinicalTrials.gov NCT01220128) evaluated the safety and immunogenicity of recombinant Wilms' tumor 1 (WT1) protein combined with the immunostimulant AS15 (WT1-immunotherapeutic) as neoadjuvant therapy administered concurrently with standard treatments in WT1-positive breast cancer patients. METHODS: Patients were treated in 4 cohorts according to neoadjuvant treatment (A: post-menopausal, hormone receptor [HR]-positive patients receiving aromatase inhibitors; B: patients receiving chemotherapy; C: HER2-overexpressing patients on trastuzumab-chemotherapy combination; D: HR-positive/HER2-negative patients on chemotherapy). Patients (cohorts A-C) were randomized (2:1) to receive 6 or 8 doses of WT1-immunotherapeutic or placebo together with standard neoadjuvant treatment in a double-blind manner; cohort D patients received WT1-immunotherapeutic in an open manner. Safety was assessed throughout the study. WT1-specific antibodies were assessed pre- and post-vaccination. RESULTS: Sixty-two patients were randomized; 60 received ≥ one dose of WT1-immunotherapeutic. Two severe toxicities were reported: diarrhea (cohort C; also reported as a grade 3 serious adverse event) and decreased left ventricular ejection fraction (cohort B; also reported as a grade 2 adverse event). Post-dose 4 of WT1-immunotherapeutic, 10/10 patients from cohort A, 0/8 patients from cohort B, 6/11 patients from cohort C, and 2/3 patients from cohort D were humoral responders. The sponsor elected to close the trial prematurely. CONCLUSIONS: Concurrent administration of WT1-immunotherapeutic and standard neoadjuvant therapy was well tolerated and induced WT1-specific antibodies in patients receiving neoadjuvant aromatase inhibitors. In patients on neoadjuvant chemotherapy or trastuzumab-chemotherapy combination, the humoral response was impaired or blunted, likely due to either co-administration of corticosteroids and/or the chemotherapies themselves.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/imunologia , Neoplasias da Mama/terapia , Vacinas Anticâncer , Proteínas Recombinantes/administração & dosagem , Proteínas WT1/administração & dosagem , Anticorpos/imunologia , Antígenos de Neoplasias/imunologia , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Neoplasias da Mama/patologia , Terapia Combinada , Feminino , Humanos , Imunoterapia , Terapia Neoadjuvante , Estadiamento de Neoplasias , Proteínas Recombinantes/imunologia , Resultado do Tratamento , Proteínas WT1/imunologia
2.
Anal Chim Acta ; 591(2): 239-47, 2007 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-17481415

RESUMO

Validation of analytical methods is a widely used and regulated step for each analytical method. However, the classical approaches to demonstrate the ability to quantify of a method do not necessarily fulfill this objective. For this reason an innovative methodology was recently introduced by using the tolerance interval and accuracy profile, which guarantee that a pre-defined proportion of future measurements obtained with the method will be included within the acceptance limits. Accuracy profile is an effective decision tool to assess the validity of analytical methods. The methodology to build such a profile is detailed here. However, as for any visual tool it has a part of subjectivity. It was then necessary to make the decision process objective in order to quantify the degree of adequacy of an accuracy profile and to allow a thorough comparison between such profiles. To achieve this, we developed a global desirability index based on the three most important validation criteria: the trueness, the precision and the range. The global index allows the classification of the different accuracy profiles obtained according to their respective response functions. A diacetyl-monoxime colorimetric assay for the determination of urea in transdermal iontophoretic extracts was used to illustrate these improvements.


Assuntos
Iontoforese , Ureia/análise , Colorimetria/métodos , Tomada de Decisões , Diacetil/análogos & derivados , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA