Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Biotechnol Bioeng ; 110(2): 500-10, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22951992

RESUMO

Anion exchange membrane adsorbers are used for contaminant removal in flow-through polishing steps in the manufacture of biopharmaceuticals. This contribution describes the clearance of minute virus of mice, DNA, and host cell proteins by three commercially available anion-exchange membranes: Sartobind Q, Mustang Q, and ChromaSorb. The Sartobind Q and Mustang Q products contain quaternary amine ligands; whereas, ChromaSorb contains primary amine based ligands. Performance was evaluated over a range of solution conditions: 0-200 mM NaCl, pH 6.0-9.0, and flow rates of 4-20 membrane volumes/min in the presence and absence of up to 50 mM phosphate and acetate. In addition contaminant clearance was determined in the presence and absence of 5 g/L monoclonal antibody. The quaternary amine based ligands depend mainly on Coulombic interactions for removal of negatively charged contaminants. Consequently, performance of Sartobind Q and Mustang Q was compromised at high ionic strength. Primary amine based ligands in ChromaSorb enable high capacities at high ionic strength due to the presence of secondary, hydrogen bonding interactions. However, the presence of hydrogen phosphate ions leads to reduced capacity. Monoclonal antibody recovery using primary amine based anion-exchange ligands may be lower if significant binding occurs due to secondary interactions. The removal of a specific contaminant is affected by the level of removal of the other contaminants. The results of this study may be used to help guide selection of commercially available membrane absorbers for flow-through polishing steps.


Assuntos
Resinas de Troca Aniônica/química , Cromatografia por Troca Iônica/instrumentação , Cromatografia por Troca Iônica/métodos , Membranas Artificiais , Vírus Miúdo do Camundongo/isolamento & purificação , Proteínas/isolamento & purificação , Adsorção , Animais , Anticorpos Monoclonais/isolamento & purificação , Células CHO , Cricetinae , Cricetulus , DNA/isolamento & purificação , Contaminação de Medicamentos/prevenção & controle , Concentração de Íons de Hidrogênio , Cloreto de Sódio/química
2.
Biotechnol Bioeng ; 110(2): 491-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22949170

RESUMO

Membrane adsorbers may be a viable alternative to the packed-bed chromatography for clearance of virus, host cell proteins, DNA, and other trace impurities. However, incorporation of membrane adsorbers into manufacturing processes has been slow due to the significant cost associated with obtaining regulatory approval for changes to a manufacturing process. This study has investigated clearance of minute virus of mice (MVM), an 18-22 nm parvovirus recognized by the FDA as a model viral impurity. Virus clearance was obtained using three commercially available anion exchange membrane adsorbers: Sartobind Q®, Mustang Q®, and ChromaSorb®. Unlike earlier studies that have focused on a single or few operating conditions, the aim here was to determine the level of virus clearance under a range of operating conditions that could be encountered in industry. The effects of varying pH, NaCl concentration, flow rate, and other competing anionic species present in the feed were determined. The removal capacity of the Sartobind Q and Mustang Q products, which contain quaternary ammonium based ligands, is sensitive to feed conductivity and pH. At conductivities above about 20 mS/cm, a significant decrease in capacity is observed. The capacity of the ChromaSorb product, which contains primary amine based ligands, is much less affected by ionic strength. However the capacity for binding MVM is significantly reduced in the presence of phosphate ions. These differences may be explained in terms of secondary hydrogen bonding interactions that could occur with primary amine based ligands.


Assuntos
Resinas de Troca Aniônica/química , Cromatografia por Troca Iônica/instrumentação , Cromatografia por Troca Iônica/métodos , Membranas Artificiais , Vírus Miúdo do Camundongo/isolamento & purificação , Adsorção , Contaminação de Medicamentos/prevenção & controle , Condutividade Elétrica , Concentração de Íons de Hidrogênio , Cloreto de Sódio
3.
Biotechnol Bioeng ; 108(11): 2645-53, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21618475

RESUMO

This contribution describes the preparation of strong anion-exchange membranes with higher protein binding capacities than the best commercial resins. Quaternary amine (Q-type) anion-exchange membranes were prepared by grafting polyelectrolyte nanolayers from the surfaces of macroporous membrane supports. A focus of this study was to better understand the role of polymer nanolayer architecture on protein binding. Membranes were prepared with different polymer chain graft densities using a newly developed surface-initiated polymerization protocol designed to provide uniform and variable chain spacing. Bovine serum albumin and immunoglobulin G were used to measure binding capacities of proteins with different size. Dynamic binding capacities of IgG were measured to evaluate the impact of polymer chain density on the accessibility of large size protein to binding sites within the polyelectrolyte nanolayer under flow conditions. The dynamic binding capacity of IgG increased nearly linearly with increasing polymer chain density, which suggests that the spacing between polymer chains is sufficient for IgG to access binding sites all along the grafted polymer chains. Furthermore, the high dynamic binding capacity of IgG (>130 mg/mL) was independent of linear flow velocity, which suggests that the mass transfer of IgG molecules to the binding sites occurs primarily via convection. Overall, this research provides clear evidence that the dynamic binding capacities of large biologics can be higher for well-designed macroporous membrane adsorbers than commercial membrane or resin ion-exchange products. Specifically, using controlled polymerization leads to anion-exchange membrane adsorbers with high binding capacities that are independent of flow rate, enabling high throughput. Results of this work should help to accelerate the broader implementation of membrane adsorbers in bioprocess purification steps.


Assuntos
Cromatografia por Troca Iônica/métodos , Membranas/química , Nanoestruturas/química , Polímeros/química , Proteínas/isolamento & purificação , Adsorção , Resinas de Troca Aniônica/química , Biotecnologia/métodos , Imunoglobulina G/isolamento & purificação , Ligação Proteica , Soroalbumina Bovina/isolamento & purificação
4.
Biotechnol Bioeng ; 108(11): 2654-60, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21618476

RESUMO

The surface-initiated polymerization protocol developed in part I was used to prepare strong anion-exchange membranes with variable polymer chain graft densities and degrees of polymerization for DNA and virus particle separations. A focus of part II was to evaluate the role of polymer nanolayer architecture on DNA and virus binding. Salmon sperm-DNA (SS-DNA) was used as model nucleic acid to measure the dynamic-binding capacities at 10% breakthrough. The dynamic-binding capacity increases linearly with increasing poly ([2-(methacryloyloxy)ethyl]trimethylammonium chloride) chain density up to the highest chain density used in this study. The new membranes yielded threefold higher SS-DNA-binding capacity (30 mg/mL) than a leading commercial membrane with the same functional group chemistry. Elution of bound DNA yielded a sharp peak, and resulted in a 13-fold increase relative to the feed concentration. This concentration effect further demonstrates the highly favorable transport properties of the newly designed Q-type membranes. However, unlike findings in part I on protein binding, SS-DNA binding was not fully reversible. Minute virus of mice (MVM) was used as model virus to evaluate the virus clearance performance of newly designed Q-type membranes. Log reduction of virus (LRV) of MVM increased with increasing polymer chain density. Membranes exhibited >4.5 LRV for the given MVM impurity load and may be capable of higher LRV values, as the MVM concentration in the flow-through fraction of these samples was below the limit of detection of the assay.


Assuntos
Cromatografia por Troca Iônica/métodos , DNA/isolamento & purificação , Membranas/química , Vírus Miúdo do Camundongo/isolamento & purificação , Nanoestruturas/química , Polímeros/química , Adsorção , Animais , Resinas de Troca Aniônica/química , Biotecnologia/métodos , Salmão
5.
PDA J Pharm Sci Technol ; 73(5): 470-486, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31101706

RESUMO

The BioPhorum Development Group Viral Clearance Workstream performed a collaborative retrospective analysis to evaluate packed bed chromatographic resin performance after repeated cycling for two commonly used chromatography steps in biopharmaceutical manufacturing: protein A and anion exchange. Key variables evaluated in the assessment included virus type, resin type, number of reuse cycles, and virus challenge. In this retrospective analysis of viral clearance data on naïve versus cycled resin, powered by the availability of a decade's worth of accumulated industry data, clearance capability was not negatively impacted by resin cycling. This finding is consistent with publications showing that surrogates for viral clearance capabilities could be employed in lieu of testing the viral clearance of cycled resins for protein A and anion exchange chromatography. The rigorous analysis of the retrospective data supports the view that viral clearance studies for cycled resins are not necessary provided that appropriate cleaning methods are applied during repeated use of the chromatography columns.LAY ABSTRACT: The manufacturing processes for biopharmaceutical products often include reusable chromatographic resins that remove process- and product-related impurities as well as potential contaminating viruses. Typically, chromatography resin is "cycled" through repeated steps of resin conditioning, product purification, and resin cleaning. The cycling approach has been evaluated in both small- and full-scale studies that show the performance parameters are maintained. The ability to remove virus is demonstrated separately in a focused small-scale virus-spiking study that is resource-intensive and costly. This paper is a retrospective review of industry data comparing virus removal by naïve and repeatedly cycled resins that summarizes the viral clearance impact of re-using protein A and anion exchange chromatography resins. The key variables evaluated in the assessment included virus type, resin type, number of cycles, and virus challenge. In this retrospective analysis, it was found that the viral clearance capability is not negatively impacted by resin cycling. This finding is consistent with other publications and supports the view that viral clearance studies for cycled resins are not necessary if appropriate cleaning methods are applied during the repeated use of the chromatography columns.Abbreviations: AAV-2, Adeno-associated virus; A-MuLV, Amphotropic murine leukemia virus; AEX, Anion-exchange chromatography; B/E, Bind and elute; BVDV, Bovine viral diarrhea virus; C.P.G., Controlled pore glass; DEAE, Diethylaminoethanol; EMCV, Encephalomyocarditis virus; FT, Flow through; HAV, Hepatitis A virus; HSV-1, Herpes simplex virus type 1; LOD, Limit of detection; LOQ, Limit of quantification; LRF, Log10 reduction factor; mAb, Monoclonal antibody; MVM, Minute virus of mice; NaOH, Sodium hydroxide; PA, Protein A; PPV, Porcine parvovirus; QA, Quaternary amine; QP, Quaternized polyethyleneimine; qPCR, Quantitative polymerase chain reaction; Reo3, Reovirus type 3; SuHV-1, Suid herpesvirus; SV40, Simian virus 40; X-MuLV, Xenotropic murine leukemia virus.


Assuntos
Produtos Biológicos/normas , Cromatografia por Troca Iônica/métodos , Contaminação de Medicamentos/prevenção & controle , Vírus/isolamento & purificação , Resinas de Troca Aniônica , Estudos Retrospectivos , Proteína Estafilocócica A/química
6.
Polymers (Basel) ; 10(7)2018 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-30960703

RESUMO

Purification of biologically-derived therapeutics is a major cost contributor to the production of this rapidly growing class of pharmaceuticals. Monoclonal antibodies comprise a large percentage of these products, therefore new antibody purification tools are needed. Small peptides, as opposed to traditional antibody affinity ligands such as Protein A, may have advantages in stability and production costs. Multiple heptapeptides that demonstrate Fc binding behavior that have been identified from a combinatorial peptide library using M13 phage display are presented herein. Seven unique peptide sequences of diverse hydrophobicity and charge were identified. All seven peptides showed strong binding to the four major human IgG isotypes, human IgM, as well as binding to canine, rat, and mouse IgG. These seven peptides were also shown to bind human IgG4 from DMEM cell culture media with 5% FCS and 5 g/L ovalbumin present. These peptides may be useful as surface ligands for antibody detection and purification purposes. Molecular docking and classical molecular dynamics (MD) simulations were conducted to elucidate the mechanisms and energetics for the binding of these peptides to the Fc region. The binding site was found to be located between the two glycan chains inside the Fc fragment. Both hydrogen bonding and hydrophobic interactions were found to be crucial for the binding interactions. Excellent agreement for the binding strength was obtained between experimental results and simulations.

7.
J Pharm Sci ; 105(12): 3496-3506, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27793346

RESUMO

The role of antibody structure (conformation) in solution rheology is probed. It is demonstrated here that pH-dependent changes in the tertiary structure of 2 mAb solutions lead to viscoelasticity and not merely a shear viscosity (η) increase. Steady shear flow curves on mAb solutions are reported over broad pH (3.0 ≤ pH ≤ 8.7) and concentration (2 mg/mL ≤ c ≤ 120 mg/mL) ranges to comprehensively characterize their rheology. Results are interpreted using size exclusion chromatography, differential scanning calorimetry, analytical ultracentrifugation, near-UV circular dichroism, and dynamic light scattering. Changes in tertiary structure with concentration lead to elastic yield stress and increased solution viscosity in solution of "mAb1." These findings are supported by dynamic light scattering and differential scanning calorimetry, which show increased hydrodynamic radius of mAb1 at low pH and a reduced melting temperature Tm, respectively. Conversely, another molecule at 120 mg/mL solution concentration is a strong viscoelastic gel due to perturbed tertiary structure (seen in circular dichroism) at pH 3.0, but the same molecule responds as a viscous liquid due to reversible self-association at pH 7.4 (verified by analytical ultracentrifugation). Both protein-protein interactions and structural perturbations govern pH-dependent viscoelasticity of mAb solutions.


Assuntos
Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Elasticidade , Animais , Células CHO , Varredura Diferencial de Calorimetria/métodos , Cromatografia em Gel/métodos , Cricetinae , Cricetulus , Soluções Farmacêuticas/análise , Soluções Farmacêuticas/química , Domínios e Motivos de Interação entre Proteínas , Reologia/métodos , Viscosidade
8.
J Funct Biomater ; 3(4): 776-98, 2012 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-24955747

RESUMO

Synthetic tissue scaffolds have a high potential impact for patients experiencing osteogenesis imperfecta. Using electrospinning, tissue scaffolds composed of hydroxyapatite/polycaprolactone (HAp/PCL) composite nanofibers were fabricated with two different HAp concentrations-1% and 10% of the solid scaffold weight. After physico-chemical scaffold characterization, rat bone marrow stromal cells were cultured on the composite scaffolds in maintenance medium and then in osteogenic medium. Quantitative PCR, colorimetric assays, immunofluorescent labeling, and electron microscopy measured osteogenic cell responses to the HAp/PCL scaffolds. In maintenance conditions, both Hap/PCL scaffolds and control scaffolds supported cell colonization through seven days with minor differences. In osteogenic conditions, the 10% HAp scaffolds exhibited significantly increased ALP assay levels at week 3, consistent with previous reports. However, qPCR analysis demonstrated an overall decrease in bone matrix-associated genes on Hap/PCL scaffolds. Osteopontin and osteocalcin immunofluorescent microscopy revealed a trend that both mineralized scaffolds had greater amounts of both proteins, though qPCR results indicated the opposite trend for osteopontin. Additionally, type I collagen expression decreased on HAp scaffolds. These results indicate that cells are sensitive to minor changes in mineral content within nanofibers, even at just 1% w/w, and elucidating the sensing mechanism may lead to optimized osteogenic scaffold designs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA