Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 127, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273324

RESUMO

Since Molar Incisor Hypomineralization was first described as a pathologic entity, public perception often suggests a considerable rise in prevalence of the respective disease. Since there are still considerable doubts regarding the etiology and-accordingly-prevention of MIH and respective therapeutic approaches are difficult this question is of considerable clinical and public interest. Accordingly, a systematic literature search in accordance with the PRISMA guidelines for systematic reviews on Medline, Cochrane Database, EMBASE, LILACS, Web of Science, Google scholar, Scopus was performed to retrieve original articles reporting the prevalence of MIH as defined by the European Academy of Pediatric Dentistry (EAPD). From initially 2360 retrieved titles, 344 full texts were assessed for possible inclusion and finally 167 articles of mainly moderate to high quality and based on data of 46'613 individuals were included in the meta-analysis. All studies published before 2001 had to be excluded since it was not possible to align the findings with the EAPD classification. Studies varied considerably regarding cohort size (25 to 23'320, mean 1'235)) and age (5.6-19 y, mean 9.8 y). Over all studies, the weighted mean for the prevalence for MIH was 12.8% (95% CI 11.5%-14.1%) and no significant changes with respect to either publication year or birthyear were found. A sub-analysis of eleven studies reporting on the prevalence in different age groups, however, revealed strong evidence for an increasing prevalence between the years 1992 (3%) and 2013 (13%).Therefore, based on data from cross-sectional studies a possible rise in prevalence of MIH remains unclear. Future prospective large-scale studies under standardized examination conditions with an emphasis on examiner calibration are needed to gain better understanding in the evolution of the prevalence of MIH.


Assuntos
Hipoplasia do Esmalte Dentário , Hipomineralização Molar , Criança , Humanos , Hipoplasia do Esmalte Dentário/epidemiologia , Prevalência , Estudos Transversais , Dente Molar/patologia , Incisivo
2.
Int J Dent Hyg ; 21(1): 172-177, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36057452

RESUMO

OBJECTIVE: The aim of this study was to investigate the resulting abrasive dentin wear using abrasive slurries with different RDA values and applying increasing brushing forces. METHODS: Forty-five bovine incisors were randomly allocated in three groups (A, B, C, n = 15). One hundred and eighty dentin samples were prepared from these incisors and allocated to twelve groups (A1-A4, B1-B4, C1-C4; n = 15). The groups were subjected to a brushing cycle (120 strokes/min, 25 min) as follows: groups A1 to A4 with an abrasive slurry (RDA = 71) applying increasing brushing forces (1, 2, 3 and 4 N). Groups B1 to B4 were brushed using an abrasive slurry (RDA = 85) and C1 to C4 (RDA = 133) applying the same above-mentioned brushing forces. Abrasive dentin wear was recorded using a stylus profilometer and compared amongst the groups using robust models. Pairwise comparisons in each model were tested and corrected after Tukey's method (α = 0.05). RESULTS: Applying 1-N brushing force resulted in the same amount of abrasive dentin wear in all groups regardless of the abrasivity of the used slurry. Increasing the brushing force to 2 N resulted in statistically significantly higher abrasive wear in all groups. This increase in abrasive wear was much higher when the slurry with high abrasivity was used (RDA = 133) compared with the lower abrasive slurry (RDA = 71). CONCLUSION: The abrasivity of the used slurry does not add to the resulting abrasive wear when the brushing force is kept at 1 N. It seems better to advise and help the patients (showing signs of non-carious cervical lesions) calibrating their brushing force to 1 N, than only to advise them to use toothpastes with lower abrasivities.


Assuntos
Dentifrícios , Abrasão Dentária , Humanos , Animais , Bovinos , Abrasão Dentária/etiologia , Escovação Dentária/efeitos adversos , Cremes Dentais , Dentina/patologia
3.
Int J Dent Hyg ; 21(1): 149-156, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36303293

RESUMO

OBJECTIVES: Very little data are known about charcoal toothpastes. The aim of this study was to counteract the missing data by determining the relative dentin abrasivity (RDA) and relative enamel abrasivity (REA) values of charcoal toothpastes. METHODS: Radioactively charged dentin and enamel samples were randomly divided into groups of eight specimens. Each group was brushed with two of total 12 charcoal toothpaste slurries and with a standard abrasive with a known RDA and REA value. The measured radioactivity in counts per minute within the slurries corresponds to the amount of dentin or enamel abraded. RDA and REA values of the charcoal toothpastes were expressed relative to the known value of the standard slurry. RESULTS: The RDA and REA values of the charcoal toothpastes have a broad range of 24-166 and 0-14, respectively. CONCLUSIONS: The RDA and REA values do not differ significantly from previously tested commercially available toothpastes. However, the lack of fluoride compounds in many of the investigated charcoal toothpastes can have a less beneficial effect for the consumers. It is very important to educate patients accordingly.


Assuntos
Abrasão Dentária , Cremes Dentais , Humanos , Cremes Dentais/efeitos adversos , Carvão Vegetal/efeitos adversos , Escovação Dentária , Dentina , Esmalte Dentário
4.
Acta Odontol Scand ; 80(6): 465-469, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35147472

RESUMO

OBJECTIVE: To investigate the effect of toothbrush bristles end configuration on the abrasive dentine wear at different brushing forces. MATERIAL AND METHODS: One hundred and sixty bovine dentine samples were randomized into eight groups (n = 20). Groups (1 to 4) were brushed with tapered-end bristles at 1-, 2-, 3-, and 4-N brushing forces, respectively. Groups (5 to 8) were brushed with round-end bristles with the same brushing forces. The brushing sequence was carried out using an abrasive slurry (RDA = 121) for 25 min. Profiles were recorded using a contact profilometer. Mean and standard deviation were calculated for the abrasive dentine wear in each group. Two-way ANOVA was used to locate any significance. The significance values were corrected after Tukey (α = 0.05). RESULTS: Brushing with tapered-end bristles resulted in statistically significantly less abrasive dentine wear than round-end bristles regardless of the applied brushing force (1 N: 4.4 ± 1.5 vs. 7.7 ± 2.0 µm; 2 N: 7.7 ± 2.1 vs. 12.2 ± 2.7 µm; 3 N: 11.3 ± 2.6 vs. 19.4 ± 3.7 µm; 4 N: 11.2 ± 2.1 vs. 25.3 ± 4.8 µm). The interaction between bristle configuration and brushing force was statistically significantly (p < 0.001). CONCLUSION: Tapered-end toothbrushes might be a safer choice for patients, especially when showing signs of non-carious cervical lesion. However, other toothbrush properties should also be considered.


Assuntos
Abrasão Dentária , Escovação Dentária , Animais , Bovinos , Análise de Variância , Dentina , Desenho de Equipamento , Abrasão Dentária/etiologia , Escovação Dentária/efeitos adversos
5.
BMC Oral Health ; 22(1): 248, 2022 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-35733139

RESUMO

BACKGROUND: Diamond particles have recently been used as abrasives in toothpastes, which raises questions about its abrasive behaviour towards enamel. This study was carried out to investigate the abrasive enamel wear caused by three diamond-loaded toothpastes (Candida White Diamond: CWD, Swiss Smile Diamond Glow: SSDG, Emoform F Diamond: EFD) and to compare it with a traditional toothpaste with silica abrasive (Colgate Total Original CTO). METHODS: Eighty bovine enamel samples were divided into four groups (n = 20) and brushed for 21,600 cycles (60 cycles/min) for 6 h at 2.5-N brushing force. The abrasive enamel wear was recorded with a contact profilometer. The median and interquartile range (IQR) of the abrasive enamel wear was calculated in each group. Pairwise comparisons were conducted using Wilcoxon signed rank exact test and the p value was adjusted according to Holm. Significance level was set at 0.05. RESULTS: Diamond-loaded toothpastes caused statistically significantly higher abrasive wear than the traditional toothpaste (p < 0.0001). SSDG caused statistically significantly higher enamel wear (19.0 µm (11.2)) than CWD (8.4 µm (4.6)) and EFD (7.3 µm (3.9)) (p < 0.0001). CONCLUSIONS: Diamond-loaded toothpastes cause higher enamel wear than toothpastes with traditional abrasives and also exhibit different abrasivity behaviour compared to each other.


Assuntos
Abrasão Dentária , Cremes Dentais , Animais , Bovinos , Esmalte Dentário , Diamante/efeitos adversos , Humanos , Fluoreto de Sódio , Abrasão Dentária/etiologia , Escovação Dentária/efeitos adversos , Cremes Dentais/efeitos adversos
6.
BMC Oral Health ; 21(1): 183, 2021 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-33836740

RESUMO

BACKGROUND: This in-vitro-study aimed to evaluate the potential of different fluoride gels to prevent gastroesophageal reflux induced erosive tooth wear. METHODS: Surface baseline profiles of a total of 50 bovine enamel specimens [randomly assigned to five groups (G1-5)] were recorded. All specimens were positioned in a custom made artificial oral cavity and perfused with artificial saliva (0.5 ml/min). Reflux was simulated 11 times a day during 12 h by adding HCl (pH 3.0) for 30 s (flow rate 2 ml/min). During the remaining 12 h (overnight), specimens were stored in artificial saliva and brushed twice a day (morning and evening) with a toothbrush and toothpaste slurry (15 brushing strokes). While specimens in the control group (G1) did not receive any further treatment, specimens in G2-5 were coated with different fluoride gels [Elmex Gelée (G2); Paro Amin Fluor Gelée (G3); Paro Fluor Gelée Natriumfluorid (G4); Sensodyne ProSchmelz Fluorid Gelée (G5)] in the evening for 30 s. After 20 days, surface profiles were recorded again and enamel loss was determined by comparing them with the baseline profiles. The results were statistically analysed using one-way analysis of variance (ANOVA) followed by Tukey`s HSD post-hoc test. RESULTS: The overall highest mean wear of enamel (9.88 ± 1.73 µm) was observed in the control group (G1), where no fluoride gel was applied. It was significantly higher (p < 0.001) compared to all other groups. G2 (5.03 ± 1.43 µm), G3 (5.47 ± 0.63 µm, p = 0.918) and G4 (5.14 ± 0.82 µm, p > 0.999) showed the overall best protection from hydrochloric acid induced erosion. Enamel wear in G5 (6.64 ± 0.86 µm) was significantly higher compared to G2 (p = 0.028) and G4 (p = 0.047). CONCLUSIONS: After 20 days of daily application, all investigated fluoride gels are able to significantly reduce gastroesophageal reflux induced loss of enamel.


Assuntos
Refluxo Gastroesofágico , Abrasão Dentária , Erosão Dentária , Desgaste dos Dentes , Animais , Bovinos , Fluoretos , Refluxo Gastroesofágico/etiologia , Refluxo Gastroesofágico/prevenção & controle , Géis , Humanos , Fluoreto de Sódio , Erosão Dentária/etiologia , Erosão Dentária/prevenção & controle
7.
BMC Oral Health ; 21(1): 295, 2021 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-34107938

RESUMO

BACKGROUND: This study aims to investigate the influence of different dentin pretreatment procedures on the resulting abrasive dentin wear. METHODS: Two groups (A, B) of 60 dentin samples each were prepared. Group A was brushed with an abrasive slurry (RDA = 85) and group B with a different abrasive slurry (RDA = 174). Four subgroups in each group (n = 15) were created (A1-A4) and (B1-B4). The subgroups were pretreated as follows: A1 + B1 with 1200-grit grinding paper, A2 + B2 with 1200- and 2000-grit papers, A3 + B3 with 1200-, 2000-, and 4000-grit papers, A4 + B4 with 1200-, 2000-, 4000-grit papers and with 1000 brushing strokes with a slurry of Elmex toothpaste. All samples were brushed for 25 min at 120 strokes/min. Abrasive dentin wear was measured for each sample profilometrically and the subgroups were compared with each other within the same group. Repeated measures one-way ANOVA was conducted to compare the subgroups and pairwise contrasts were estimated for multiple testing according to Tukey (α = 0.05). RESULTS: The resulting abrasive dentin wear in group A ranged between 15.3 ± 3.4 µm and 17.3 ± 5.5 µm and between 20.3 ± 6.8 µm and 22.5 ± 2.6 µm in group B. No statistically significant difference was noticed between any subgroups within the same group (p ˃ 0.05). CONCLUSIONS: Different dentin pretreatment procedures do not affect the resulting abrasive dentin wear independent of the RDA value of the employed abrasive slurry.


Assuntos
Abrasão Dentária , Erosão Dentária , Dentina , Humanos , Abrasão Dentária/etiologia , Escovação Dentária , Cremes Dentais
8.
Int J Dent Hyg ; 19(4): 355-359, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34270163

RESUMO

OBJECTIVE: To investigate the influence of toothbrush bristle stiffness and applied brushing force on the resulting abrasive dentine wear in vitro. METHODS: One hundred sixty bovine dentine samples were randomly allocated in eight groups (n = 20). Groups one to four were brushed with a soft-bristle toothbrush with soft bristles applying 1, 2, 3 and 4 N brushing force, respectively. Groups five to eight were brushed with a medium-bristle toothbrush applying the same aforementioned brushing forces (120 strokes/min, abrasive slurry (RDA = 121), 25 min). Profiles were recorded before and after the brushing sequence, and the median and interquartile range of abrasive dentine wear were calculated and compared using two-way ANOVA and pairwise tests corrected after Tukey (α = 0.05). RESULTS: At 1, 2 and 3 N brushing force, the tested toothbrushes caused no significantly different abrasive dentine wear. At 4 N brushing force, the medium-bristle toothbrush caused statistically significantly higher abrasive force than the soft-bristle toothbrush. Using the medium-bristle toothbrush, abrasive dentine wear statistically significantly increased with increasing brushing force from 1 to 3 N. However, increasing the brushing force to 4 N did not result in statistically significantly higher wear. Using the soft-bristle toothbrush, abrasive dentine wear statistically significantly increased with increasing brushing force from 1 to 2 N. However, increasing the brushing force to 3 or 4 N did not result in statistically significantly higher wear. CONCLUSION: The soft-bristle toothbrush tends to cause less abrasive wear with increasing brushing force than the medium-bristle toothbrush.


Assuntos
Abrasão Dentária , Escovação Dentária , Análise de Variância , Animais , Bovinos , Dentina , Humanos , Abrasão Dentária/etiologia
9.
Int J Dent Hyg ; 19(4): 407-412, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34115427

RESUMO

OBJECTIVE: This in vitro study aimed to investigate the effect of a sonic toothbrush on the resulting abrasive dentine wear using toothpastes with different abrasivities compared to the use of a manual toothbrush. METHODS: Ninety-six bovine dentine samples were divided into six groups and subjected to a brushing sequence (sonic: 20 min, 0.9 N, 10 strokes/min; manual: 20 min, 1.6 N, 60 strokes/min) as follows: group 1: Elmex Sensitive Plus (RDA = 28) + manual toothbrush; group 2: Elmex Sensitive + sonic toothbrush; group 3: Elmex Kariesschutz (RDA = 65) + manual toothbrush; group 4: Elmex Kariesschutz +sonic toothbrush; group 5: Colgate Total Original (RDA = 121) + manual toothbrush; and group 6: Colgate Total Original +sonic toothbrush. The abrasive dentine wear was measured profilometrically. RESULTS: The median (IQR) abrasive dentine wear was as follows: Elmex Sensitive Plus (manual toothbrush: 2.7 µm (0.8), sonic toothbrush: 3.1 µm (1.9)); Elmex Kariesschutz (manual toothbrush: 4.9 µm (1.4), sonic toothbrush: 6.4 µm (2.1)); and Colgate Total Original (manual toothbrush: 5.2 µm (1.1), sonic toothbrush: 9.0 µm (3.1)). Differences in dentine wear between sonic and manual toothbrushes were statistically significant only in the groups brushed with Elmex Kariesschutz and Colgate Total Original (p ≤ 0.05). CONCLUSION: Brushing with a sonic toothbrush could result in a higher abrasive dentine wear compared to manual toothbrush when combined with toothpastes with high abrasivity values.


Assuntos
Abrasão Dentária , Cremes Dentais , Animais , Bovinos , Dentina , Humanos , Fluoreto de Sódio , Abrasão Dentária/etiologia , Escovação Dentária , Cremes Dentais/efeitos adversos
10.
Caries Res ; 54(2): 127-133, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31910423

RESUMO

OBJECTIVES: This in situ study aimed to evaluate whether rinsing with a calcium-containing solution prior to an erosive attack reduces the softening of enamel. MATERIALS AND METHODS: A total of 240 bovine enamel samples with determined baseline surface microhardness (KHN) were allocated to 5 runs in which each of the 12 volunteers performed the following experiment: 4 enamel samples were inserted in a custom-made intraoral appliance and carried in the mouth (upper jaw) for 30 min before each volunteer either rinsed his mouth for 60 s with a fluoride- and stannous ion-containing dental erosion protection mouth rinse as positive control (run 1), milk (run 2), a solution prepared from a 500-mg calcium effervescent tablet dissolved in 100 mL (run 3) or 200 mL (run 4) water, or did not perform any rinsing with a test solution before the erosive attack (run 5, negative control). To simulate the erosive attack, volunteers rinsed their mouth with a commercial soft drink (Sprite Zero) for 60 s and afterwards with water to stop the erosive process. Finally, surface microhardness was measured again and hardness loss (ΔKHN) calculated. A mixed effect model was fitted to the data set to investigate whether the different runs showed differences with respect to ΔKHN. RESULTS: No significant difference in softening of enamel (mean of ΔKHN; lower confidence level/upper confidence level) was observed between the negative control run 5 (50.7; 60.8/40.6), run 2 (50.7; 60.8/40.6), run 3 (38.7; 48.8/28.6) and run 4 (40.7; 50.8/30.6) (p > 0.05, respectively). Enamel softening in the positive control run 1 (25.4; 35.6/15.3) was significantly lower compared to the softening in run 5 (p < 0.001). No significant difference was observed between run 1 and run 3 (p = 0.09). CONCLUSION: Other than the fluoride- and stannous ion-containing dental erosion protection mouth rinse, none of the investigated calcium-containing solutions is able to significantly reduce erosion-induced softening of enamel.


Assuntos
Esmalte Dentário , Erosão Dentária , Animais , Cálcio , Bovinos , Fluoretos , Dureza , Humanos , Erosão Dentária/prevenção & controle
11.
Caries Res ; 54(4): 336-342, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32998154

RESUMO

OBJECTIVES: This in vitro study aimed to evaluate and compare the effect of two different bioactive glasses, a hydroxyapatite-containing, fluoride-free toothpaste (HTP) and a fluoride toothpaste (FTP) on the remineralization behavior of initial caries lesions. MATERIALS AND METHODS: A total of 100 bovine enamel samples were randomly allocated to five groups of 20 samples each: NC = negative control group (artificial saliva); HTP = HTP group (Karex); FTP = FTP group (Elmex caries protection, 1,400 ppm); FTP + BGnano = FTP followed by Actimins bioactive glass; FTP + BGamorph = FTP followed by Schott bioactive glass. Radiographic documentation (advanced transversal microradiography; aTMR) was applied before and after all samples were exposed to a demineralizing gel for 10 days. Over a period of 28 days, samples were covered twice a day (every 12 h) with a toothpaste slurry of the respective test group or with artificial saliva in NC for 60 s and brushed with 15 brushing strokes. Samples in FTP + BGnano and FTP + BGamorph were additionally treated with the respective bioactive glass slurry for 30 s after brushing with the FTP. In the meantime, all samples were stored in artificial saliva. After 28 days, the structure of all samples was assessed again using aTMR and compared to the values measured after demineralization. The statistical evaluation of the integrated mineral loss was performed using Kruskal-Wallis test followed by a post hoc Conover test. RESULTS: The FTP revealed the significantly highest increase of mineral content while the HTP showed the significantly lowest remineralization. Compared to artificial saliva, the use of the HTP or the combined application of FTP followed by bioactive glasses (FTP + BGnano and FTP + BGamorph) showed no significant remineralization. CONCLUSION: Under remineralizing in vitro conditions, brushing with 1,400 ppm FTP induced significantly more remineralization compared to storage in artificial saliva. The additional administration of both bioactive glasses as well as the substitutional brushing with an HTP resulted in significantly less remineralization compared to brushing with 1,400 ppm FTP.


Assuntos
Durapatita , Cremes Dentais , Animais , Cariostáticos , Bovinos , Esmalte Dentário , Fluoretos , Microrradiografia , Remineralização Dentária
12.
J Esthet Restor Dent ; 32(4): 416-423, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32277866

RESUMO

OBJECTIVE: The aim of this study was to evaluate and compare surface roughness, gloss, and color change of dental enamel after being brushed with toothpastes containing diamond powder and traditional abrasives. MATERIALS AND METHODS: Seventy enamel slabs were derived from 70 bovine incisors. The slabs were brushed with six different toothpastes and artificial saliva as a negative control. The specimens were then stained with black tea mixed with citric acid (3 days, pH = 4) and again brushed with the same toothpastes. Ra (contact profilometer), gloss (glossmeter), and color (CIE L* a* b* system) values were measured after each step. RESULTS: Emoform-F Diamond (contains diamond powder and traditional abrasives) offered significantly the best improvement of Ra and gloss values after the first brushing sequence and the best recovery of the brightness of enamel after staining and second brushing sequence (P < .05). AMC 2.5 (contains only diamond powder as abrasive) was not able to offer such improvement. CONCLUSION: Diamond powder as an additional abrasive in toothpastes could be able to offer a further improvement of Ra , gloss, and color values of enamel.


Assuntos
Diamante , Cremes Dentais , Animais , Bovinos , Cor , Esmalte Dentário , Propriedades de Superfície , Escovação Dentária
13.
J Adhes Dent ; 19(2): 147-155, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28443834

RESUMO

PURPOSE: To evaluate the influence of different pretreatments on the microtensile bond strength (µTBS) of an etch-and-rinse adhesive to eroded dentin. MATERIALS AND METHODS: Thirty-six human teeth were ground down to their dentin layer and randomly divided into six groups (G1-G6; n = 6), G1 being the control group. Only in the test groups (G2-G6) were samples subjected to erosion using citric acid (pH 2.6) 10 x 2 min per day for five days. Between the erosive attacks, samples were stored in artificial saliva. After pretreatment - none (G1); none (G2); 2% chlorhexidine (30 s) (G3); prolonged primer application (1 min) (G4); roughening with a diamond bur (G5) and 10.5% NaOCl (1 min) (G6) - the adhesive OptiBond FL was applied. After the application of composite, samples were stored in water (7 d) and µTBS was determined. Data were evaluated using one-way ANOVA and Dunnett-T post-hoc test (p < 0.05). RESULTS: Eroded dentin without pretreatment (G2) resulted in significant reduction of µTBS compared with uneroded dentin (G1). µTBS after pretreatment with a diamond bur (G5) or NaOCl (G6) was not significantly different from that of the uneroded control group (G1). µTBS after pretreatment with chlorhexidine (G3) or with prolonged primer application (G4) was significantly lower than in the uneroded control group (G1), and not significantly different from the eroded control group (G2). CONCLUSION: The present data suggests that µTBS to eroded dentin pretreated with bur abrasion or NaOCl is similar to the µTBS to sound, uneroded dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Dentina , Humanos , Teste de Materiais , Distribuição Aleatória , Cimentos de Resina , Resistência à Tração
14.
Oral Health Prev Dent ; 15(1): 79-87, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28232978

RESUMO

PURPOSE: To determine whether reducing the light-curing time of resin-based surface sealants influences their potential to prevent erosion, as well as their mechanical stability and degree of conversion. MATERIALS AND METHODS: 240 bovine dentin samples were randomly divided into 10 groups (1-10). The 24 samples of one group remained unsealed and served as control. Three groups were sealed with Seal&Protect, another three groups with K-0184 (experimental sealant), and the remaining three groups with Syntac Classic. One group of each sealant was light cured for 10 s, another group of that sealant for 5 s, and the last group of the respective sealant for 2 s at 1014 mW/cm2. After 7-day water storage, the first measurement of sealant permeability was performed. The samples were stored in hydrochloric acid (pH 2.3) for 24 h and the dentin calcium release was measured by atomic absorption spectroscopy. Following thermomechanical loading (5000 cycles, 5°/50°C, 12,000 brushing strokes), the second measurement of sealant permeability was performed. Additionally, the sealants' degrees of conversion (DC) were determined by FTIR spectroscopy. RESULTS: For the first and second measurements, no significant difference in the permeability of the sealants was observed when the light-curing duration was shortened. Additionally, no significant difference in the stability of the respective sealants was observed when light cured for different durations. Regarding DC, a significant influence of the light-curing duration was observed (p = 0.000). CONCLUSION: Shortening the light-curing time has no influence on permeability and stability of the investigated sealants. However, short light-curing times (2 s or 5 s) decrease the DC of the tested sealants.


Assuntos
Lâmpadas de Polimerização Dentária , Dentina , Resinas Sintéticas , Erosão Dentária/prevenção & controle , Animais , Bovinos , Teste de Materiais , Distribuição Aleatória , Propriedades de Superfície , Fatores de Tempo
15.
BMC Oral Health ; 17(1): 12, 2016 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-27430972

RESUMO

BACKGROUND: The degree of conversion (DC) of resin based materials depends, beside other factors, on the light-intensity applied during light curing. A lower DC might be correlated with an increased cytotoxicity of the respective materials. Therefore, aim of the present study was to investigate the influence of the distance between light-curing tip and adhesives on their cytotoxicity and degree of conversion (DC). METHODS: For the cytotoxicity assay, a total of 98 bovine dentine samples were prepared, distributed to seven groups (G1-G7; n = 14) and treated as follows: G1: untreated; G2-G4: OptiBond FL; G5-G7: OptiBond All-In-One. Adhesives were light-cured (1200 mW/cm(2)) at 1 mm (G2;G5), 4 mm (G3;G6) or 7 mm (G4;G7) distance. Samples were stored in culture media for 24 h and extracts were added to cell cultures (dental pulp cells and gingival fibroblasts) for a further 24 h. Finally, released lactate dehydrogenase activity (LDH) was photometrically determined, as measure for the cytotoxic effects of the extracts. The cytotoxicity assay was performed three times. Additionally, the DC of the adhesives was determined by FTIR spectroscopy. DC measurements were performed five times. RESULTS: For both cell types, no significant difference of LDH release was observed between untreated control group (G1) and treated groups G2-G7 (p > 0.05, respectively), between the groups treated with same adhesive and light-cured at different distance (p > 0.05, respectively), as well as between groups treated with different adhesives and light-cured at the same distance (p > 0.05, respectively). Within the respective adhesive, no significant difference in the DC was observed when light-cured at different distance (p > 0.05, respectively), while OptiBond FL showed significantly higher DCs compared to OptiBond All-In-One when light-cured at same distances (p < 0.05, respectively). CONCLUSIONS: The distance between light-curing tip and adhesive surface does not significantly influence either the cytotoxicity or the DC of the tested adhesives.


Assuntos
Lâmpadas de Polimerização Dentária , Cimentos Dentários , Animais , Bovinos , Resinas Compostas , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Cimentos de Resina , Espectroscopia de Infravermelho com Transformada de Fourier
17.
Clin Oral Investig ; 19(5): 1021-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25248949

RESUMO

OBJECTIVES: This study investigated the influence of proximal box elevation (PBE) with composite resin when applied to deep proximal defects in root-filled molars with mesio-occluso-distal (MOD) cavities, which were subsequently restored with computer-aided designed/computer-aided manufacturing (CAD/CAM) ceramic or composite restorations. MATERIALS AND METHOD: Root canal treatment was performed on 48 human mandibular molars. Standardized MOD cavities were prepared with the distal box located 2 mm below the cemento-enamel junction (CEJ). The teeth were randomly assigned to one of four experimental groups (n = 12). In groups G1 and G2, the distal proximal box was elevated up to the level of the CEJ with composite resin (PBE). No elevation was performed in the remaining two groups (G3, G4). CAD/CAM restorations were fabricated with feldspathic ceramic (Vita Mark II, CER) in groups G1 (PBE-CER) and G3 (CER) or with resin nano-ceramic blocks (Lava Ultimate, LAV) in groups G2 (PBE-LAV) and G4 (LAV). Replicas were taken before and after thermomechanical loading (TML; 1.2 Mio cycles; 49 N; 3,000 thermocycles between 50 °C and 5 °C). Following TML, load was applied until failure. Fracture analysis was performed under a stereomicroscope (×16). Marginal quality before and after TML (tooth restoration, composite restoration) was evaluated using scanning electron microscopy (×200). RESULTS: After TML, lower percentages of continuous margins were observed in groups G1-G3 compared with pre-TML assessments; however, the differences were not statistically significant. For group G4-LAV, the marginal quality after TML was significantly better than in any other group. The highest mean fracture value was recorded for group G4. No significant difference was found for this value between the groups with PBE compared with the groups without PBE, regardless of the material used. The specimens restored with ceramic onlays exhibited fractures that were mainly restricted to the restoration while, in teeth restored with composite onlays, the percentage of catastrophic failures (fractures beyond bone level) was increased. CONCLUSION: PBE had no impact on either the marginal integrity or the fracture behavior of root canal-treated mandibular molars restored with feldspathic ceramic onlays. CAD/CAM-fabricated composite onlays were more favorable than ceramic onlays in terms of both marginal quality and fracture resistance, particularly in specimens without PBE. CLINICAL RELEVANCE: Composite onlays with or without PBE may be a viable approach for the restoration of root-filled molars with subgingival MOD cavities.


Assuntos
Cerâmica/química , Resinas Compostas/química , Desenho Assistido por Computador , Cárie Dentária/terapia , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Restaurações Intracoronárias , Dente Molar/cirurgia , Tratamento do Canal Radicular , Condicionamento Ácido do Dente , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Mandíbula , Materiais Restauradores do Canal Radicular
18.
Oral Health Prev Dent ; 13(4): 349-55, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25197725

RESUMO

PURPOSE: To determine the influence of the relative enamel abrasivity (REA) of fluoridated toothpaste on the uptake of KOH-soluble and structurally bound fluoride into enamel. MATERIALS AND METHODS: Bovine enamel samples were randomly allocated to 6 groups (n=36 per group). Groups A to C were treated with sodium fluoride (NaF) toothpastes and groups D to F with amine fluoride (AmF) toothpastes (1500 ppm F each). The REA in groups A and D was 2, in groups B and E it was 6 and in groups C and F it was 9. Twice a day, 18 samples of each group were immersed for 2 min in a slurry (toothpaste:artificial saliva=1:3), while the remaining samples were brushed with the respective slurry (2.5 N force; 60 strokes/min; 2 min). All samples were stored at 37°C and 100% humidity. After five days, the amount of KOH-soluble and structurally bound fluoride was determined and statistically compared by Scheffe's post-hoc tests. RESULTS: REA value and mode of application (immersion or brushing) had no significant influence on the amount of either kind of fluoride from NaF toothpastes. Only for the NaF toothpaste with REA 6 was the amount of KOH-soluble fluoride significantly higher after brushing. With AmF toothpastes, KOH-soluble and structurally bound fluoride concentrations were significantly higher when the samples were brushed. Furthermore, in the REA-2 group, the amounts of KOH-soluble fluoride (brushed or immersed) and structurally bound fluoride (brushed) were significantly higher than in the other groups. CONCLUSION: The REA dependency of KOH-soluble and structurally bound fluoride was found only for the AmF toothpastes. Using AmF toothpaste, the mode of application influenced the uptake of KOH-soluble and structurally bound fluoride into enamel.


Assuntos
Cariostáticos/farmacocinética , Esmalte Dentário/efeitos dos fármacos , Fluoretos/farmacocinética , Abrasão Dentária/metabolismo , Cremes Dentais/administração & dosagem , Amino Álcoois/química , Amino Álcoois/farmacocinética , Animais , Fluoreto de Cálcio/química , Fluoreto de Cálcio/farmacocinética , Cariostáticos/química , Bovinos , Precipitação Química , Esmalte Dentário/metabolismo , Fluoretos/química , Umidade , Hidróxidos/química , Imersão , Compostos de Potássio/química , Distribuição Aleatória , Saliva Artificial/química , Fluoreto de Sódio/química , Fluoreto de Sódio/farmacocinética , Solubilidade , Temperatura , Fatores de Tempo , Escovação Dentária/métodos , Cremes Dentais/química
19.
Acta Odontol Scand ; 72(8): 825-30, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24850503

RESUMO

OBJECTIVE: To test the stability of two conventional adhesives when combined with a low-viscosity caries infiltrant used for sealing sound enamel against toothbrush abrasion and acid challenge in vitro. MATERIALS AND METHODS: Bovine enamel discs (Ø = 3 mm) randomly assigned to three groups (n = 10/group) were etched with 37% phosphoric acid for 30 s and treated with resins of different monomer contents forming three test groups: (1) Untreated specimens (Control); (2) Infiltrant (Icon, DMG) + conventional enamel bonding adhesive (Heliobond, Ivoclar Vivadent); and (3) Infiltrant + conventional orthodontic adhesive (Transbond XT Primer, 3M Unitek). All specimens were immersed in hydrochloric acid (pH 2.6) for up to 9 days, during which they were exposed to 1825 toothbrush-strokes per day. Calcium dissolution was assessed using Arsenazo III method at 24-h intervals. Data were analyzed by Kruskal-Wallis and Wilcoxon signed ranks tests. RESULTS: Cumulative calcium dissolution for the untreated specimens (39.75 ± 7.32 µmol/ml) exceeded the sealed groups (Icon + Heliobond: 23.44 ± 7.03 µmol/ml; Icon + Transbond XT Primer: 22.17 ± 5.34 µmol/ml). Untreated specimens presented a relatively constant calcium dissolution rate throughout the experimental period, whereas the sealed groups presented a gradual increase indicating weakening of the seal by toothbrush abrasion. Both sealed groups presented significantly lower daily calcium dissolution at all time points compared to the control, except for Group 2 on the last measurement day. CONCLUSIONS: Low-viscosity caries infiltrant application on sound enamel prior to conventional resin application provided a protective effect against enamel demineralization, but this effect was not stable when challenged mechanically by toothbrush abrasion.


Assuntos
Esmalte Dentário/patologia , Selantes de Fossas e Fissuras/uso terapêutico , Resinas Sintéticas/uso terapêutico , Abrasão Dentária/prevenção & controle , Erosão Dentária/prevenção & controle , Condicionamento Ácido do Dente/métodos , Acrilatos/uso terapêutico , Animais , Arsenazo III , Cálcio/análise , Bovinos , Corantes , Esmalte Dentário/química , Materiais Dentários/química , Ácido Clorídrico/química , Ácidos Fosfóricos/química , Distribuição Aleatória , Cimentos de Resina/uso terapêutico , Solubilidade , Fatores de Tempo , Escovação Dentária/instrumentação
20.
Eur J Orthod ; 36(5): 595-602, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24385411

RESUMO

SUMMARY BACKGROUND/OBJECTIVES: White spot lesions (WSLs) are unwelcome side effects of fixed appliances that compromise the treatment outcome. Recently, infiltration of WSLs has been introduced as a viable treatment alternative. The objective was to evaluate the colour improvement of WSLs and their stability against discolouration following infiltration, fluoride, or micro-abrasion treatments in vitro. MATERIALS/METHODS: Artificial WSLs were created in bovine enamel (N = 96) using acidic buffer solution (pH 5, 10 days) and were randomly allocated to four groups. Specimens were treated with infiltration (Icon, DMG), fluoride (Elmex Caries Protection, GABA), and micro-abrasion (Opalustre, Ultradent) or remained untreated (control). Groups were discoloured for 24 hours in tea or tea + citric acid. Colour components and visible colour change (L*, a*, b*, ΔE) were measured spectrophotometrically on following time points: baseline, after WSL formation, after treatment, and during discolouration (8, 16, and 24 hours). Data were analysed using Kruskal-Wallis and Mann-Whitney tests. RESULTS: WSL formation increased (L*) in all groups. Only infiltration reduced this effect to baseline. Highest ΔE improvement was obtained by infiltration and micro-abrasion followed by fluoride. This improvement was stable only for infiltration during discolouration. L*, a*, and b* changed significantly during discolouration in all groups except infiltration. Within the same treatment group, discolouration solutions did not differ significantly. LIMITATIONS: In vitro testing cannot replicate the actual mode of colour improvement or stability but can be used for ranking materials and techniques. CONCLUSIONS/IMPLICATIONS: Infiltration and micro-abrasion treatments were capable of diminishing the whitish appearance of WSLs. Only infiltrated WSLs were stable following discolouration challenge.


Assuntos
Cariostáticos/uso terapêutico , Cárie Dentária/terapia , Microabrasão do Esmalte/métodos , Fluoretos/uso terapêutico , Resinas Sintéticas/uso terapêutico , Animais , Bovinos , Ácido Cítrico/efeitos adversos , Cor , Cárie Dentária/patologia , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/patologia , Diaminas/uso terapêutico , Polietilenoglicóis/uso terapêutico , Ácidos Polimetacrílicos/uso terapêutico , Distribuição Aleatória , Espectrofotometria/métodos , Chá/efeitos adversos , Descoloração de Dente/etiologia , Descoloração de Dente/patologia , Remineralização Dentária/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA