Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 277
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 144(6): 426-437, 2021 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-34039025

RESUMO

BACKGROUND: In the randomized COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation), among 614 patients with heart failure with 3+ or 4+ secondary mitral regurgitation (MR), transcatheter mitral valve repair (TMVr) with the MitraClip reduced MR, heart failure hospitalizations, and mortality and improved quality of life compared with guideline-directed medical therapy (GDMT) alone. We aimed to examine the prognostic relationship between MR reduction and outcomes after TMVr and GDMT alone. METHODS: Outcomes in COAPT between 30 days and 2 years were examined on the basis of the severity of residual MR at 30 days. RESULTS: TMVr-treated patients had less severe residual MR at 30 days than GDMT-treated patients (0/1+, 2+, and 3+/4+: 72.9%, 19.9%, and 7.2% versus 8.2%, 26.1%, and 65.8%, respectively [P<0.0001]). The rate of composite death or heart failure hospitalizations between 30 days and 2 years was lower in patients with 30-day residual MR of 0/1+ and 2+ compared with patients with 30-day residual MR of 3+/4+ (37.7% versus 49.5% versus 72.2%, respectively [P<0.0001]). This relationship was consistent in the TMVr and GDMT arms (Pinteraction=0.92). The improvement in Kansas City Cardiomyopathy Questionnaire score from baseline to 30 days was maintained between 30 days and 2 years in patients with 30-day MR ≤2+ but deteriorated in those with 30-day MR 3+/4+ (-0.3±1.7 versus -9.4±4.6 [P=0.0008]) consistently in both groups (Pinteraction=0.95). CONCLUSIONS: In the COAPT trial, reduced MR at 30 days was associated with greater freedom from death or heart failure hospitalizations and improved quality of life through 2-year follow-up whether the MR reduction was achieved by TMVr or GDMT. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01626079.


Assuntos
Insuficiência Cardíaca/epidemiologia , Insuficiência da Valva Mitral/epidemiologia , Qualidade de Vida , Cateterismo Cardíaco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Próteses Valvulares Cardíacas , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/terapia , Avaliação de Resultados em Cuidados de Saúde , Prognóstico , Vigilância em Saúde Pública , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença , Fatores de Tempo
2.
N Engl J Med ; 379(24): 2307-2318, 2018 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-30280640

RESUMO

BACKGROUND: Among patients with heart failure who have mitral regurgitation due to left ventricular dysfunction, the prognosis is poor. Transcatheter mitral-valve repair may improve their clinical outcomes. METHODS: At 78 sites in the United States and Canada, we enrolled patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy. Patients were randomly assigned to transcatheter mitral-valve repair plus medical therapy (device group) or medical therapy alone (control group). The primary effectiveness end point was all hospitalizations for heart failure within 24 months of follow-up. The primary safety end point was freedom from device-related complications at 12 months; the rate for this end point was compared with a prespecified objective performance goal of 88.0%. RESULTS: Of the 614 patients who were enrolled in the trial, 302 were assigned to the device group and 312 to the control group. The annualized rate of all hospitalizations for heart failure within 24 months was 35.8% per patient-year in the device group as compared with 67.9% per patient-year in the control group (hazard ratio, 0.53; 95% confidence interval [CI], 0.40 to 0.70; P<0.001). The rate of freedom from device-related complications at 12 months was 96.6% (lower 95% confidence limit, 94.8%; P<0.001 for comparison with the performance goal). Death from any cause within 24 months occurred in 29.1% of the patients in the device group as compared with 46.1% in the control group (hazard ratio, 0.62; 95% CI, 0.46 to 0.82; P<0.001). CONCLUSIONS: Among patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy, transcatheter mitral-valve repair resulted in a lower rate of hospitalization for heart failure and lower all-cause mortality within 24 months of follow-up than medical therapy alone. The rate of freedom from device-related complications exceeded a prespecified safety threshold. (Funded by Abbott; COAPT ClinicalTrials.gov number, NCT01626079 .).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hospitalização/estatística & dados numéricos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/tratamento farmacológico , Insuficiência da Valva Mitral/mortalidade , Intervenção Coronária Percutânea , Falha de Prótese , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
3.
N Engl J Med ; 379(12): 1107-1117, 2018 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-30145941

RESUMO

BACKGROUND: Lorcaserin, a selective serotonin 2C receptor agonist that modulates appetite, has proven efficacy for weight management in overweight or obese patients. The cardiovascular safety and efficacy of lorcaserin are undefined. METHODS: We randomly assigned 12,000 overweight or obese patients with atherosclerotic cardiovascular disease or multiple cardiovascular risk factors to receive either lorcaserin (10 mg twice daily) or placebo. The primary safety outcome of major cardiovascular events (a composite of cardiovascular death, myocardial infarction, or stroke) was assessed at an interim analysis to exclude a noninferiority boundary of 1.4. If noninferiority was met, the primary cardiovascular efficacy outcome (a composite of major cardiovascular events, heart failure, hospitalization for unstable angina, or coronary revascularization [extended major cardiovascular events]) was assessed for superiority at the end of the trial. RESULTS: At 1 year, weight loss of at least 5% had occurred in 1986 of 5135 patients (38.7%) in the lorcaserin group and in 883 of 5083 (17.4%) in the placebo group (odds ratio, 3.01; 95% confidence interval [CI], 2.74 to 3.30; P<0.001). Patients in the lorcaserin group had slightly better values with respect to cardiac risk factors (including blood pressure, heart rate, glycemic control, and lipids) than those in the placebo group. During a median follow-up of 3.3 years, the rate of the primary safety outcome was 2.0% per year in the lorcaserin group and 2.1% per year in the placebo group (hazard ratio, 0.99; 95% CI, 0.85 to 1.14; P<0.001 for noninferiority); the rate of extended major cardiovascular events was 4.1% per year and 4.2% per year, respectively (hazard ratio, 0.97; 95% CI, 0.87 to 1.07; P=0.55). Adverse events of special interest were uncommon, and the rates were generally similar in the two groups, except for a higher number of patients with serious hypoglycemia in the lorcaserin group (13 vs. 4, P=0.04). CONCLUSIONS: In a high-risk population of overweight or obese patients, lorcaserin facilitated sustained weight loss without a higher rate of major cardiovascular events than that with placebo. (Funded by Eisai; CAMELLIA-TIMI 61 ClinicalTrials.gov number, NCT02019264 .).


Assuntos
Fármacos Antiobesidade/uso terapêutico , Benzazepinas/uso terapêutico , Doenças Cardiovasculares/complicações , Hipoglicemia/induzido quimicamente , Obesidade/tratamento farmacológico , Sobrepeso/tratamento farmacológico , Redução de Peso/efeitos dos fármacos , Idoso , Fármacos Antiobesidade/efeitos adversos , Insuficiência da Valva Aórtica/induzido quimicamente , Benzazepinas/efeitos adversos , Doenças Cardiovasculares/induzido quimicamente , Doenças Cardiovasculares/epidemiologia , Diabetes Mellitus Tipo 2/complicações , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Sobrepeso/complicações , Fatores de Risco
4.
Circulation ; 139(1): 37-47, 2019 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-30586701

RESUMO

BACKGROUND: Secondary mitral regurgitation (SMR) occurs in the absence of organic mitral valve disease and may develop as the left ventricle dilates or remodels or as a result of leaflet tethering with impaired coaptation, most commonly from apical and lateral distraction of the subvalvular apparatus, with late annular dilatation. The optimal therapy for SMR is unclear. This study sought to evaluate the 1-year adjudicated outcomes of all patients with SMR undergoing the MitraClip procedure in the EVEREST II (Endovascular Valve Edge-to-Edge Repair Study) Investigational Device Exemption program, which is comprised of the randomized clinical trial, the prospective High-Risk Registry, and the REALISM Continued Access Registry (Multicenter Study of the MitraClip System). METHODS: Patients with 3+/4+ SMR enrolled in EVEREST II were stratified by non-high surgical risk (non-HR) and high surgical risk (HR) status (defined as Society of Thoracic Surgeons risk of mortality ≥12% or predefined risk factors). Clinical, echocardiographic, and functional outcomes at 1 year were evaluated. RESULTS: A total of 616 patients (482 HR, 134 non-HR; mean age, 73.3±10.5 years; Society of Thoracic Surgeons risk, 10.2±6.9%) with SMR underwent the MitraClip procedure. At baseline, 80.5% of patients were in New York Heart Association class III/IV. Major adverse events at 30 days included death (3.6%), stroke (2.3%), and renal failure (1.5%). At discharge, 88.8% had MR ≤2+. At 1 year, there were 139 deaths, and the Kaplan-Meier estimate of freedom from mortality was 76.8%. The majority of surviving patients (84.7%) remained with MR ≤2+ and New York Heart Association class I/II (83.0%). Kaplan-Meier survival at 1 year was 74.1% in HR patients and 86.4% in non-HR patients ( P=0.0175). At 1 year, both groups achieved comparable MR reduction (MR ≤2+, 84.0% versus 87.0%) and improvement in left ventricular end-diastolic volume (-8.0 mL versus -12.7 mL), whereas New York Heart Association class I/II was found in 80.1% versus 91.8% ( P=0.008) of HR and non-HR patients, respectively. In HR patients, the annualized rate of heart failure hospitalizations decreased from 0.68 to 0.46 in the 12 months before to 12 months after the procedure ( P<0.0001). CONCLUSIONS: Transcatheter mitral valve repair with the MitraClip in patients with secondary MR is associated with acceptable safety, reduction of MR severity, symptom improvement, and positive ventricular remodeling. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov . Unique identifiers: NCT00209274, NCT01940120, and NCT01931956.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Ecocardiografia Transesofagiana , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
5.
Circulation ; 137(24): 2557-2567, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29530883

RESUMO

BACKGROUND: Comparative echocardiographic data on transcatheter aortic valve replacement systems from randomized trials are limited. The REPRISE III trial (Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Randomized Clinical Evaluation) is a multicenter, randomized comparison of a mechanically expanded (Lotus) versus self-expanding (CoreValve) transcatheter aortic valve replacement device. This analysis rigorously assesses Doppler-derived valve hemodynamics and the impact on outcomes at 1 year in patients with extreme/high surgical risk treated with Lotus and CoreValve from REPRISE III. METHODS: REPRISE III includes patients with extreme- and high-risk aortic stenosis. Patients were enrolled at 55 centers. All transthoracic echocardiograms with Doppler were obtained following a standard protocol up to 12 months postimplant and analyzed by a core laboratory. Valve size, mean gradient, aortic valve area, and Doppler velocity index and their impact on clinical outcomes are reported. Additional parameters including paravalvular leak were evaluated using a multiparametric approach. RESULTS: A total of 912 patients were randomly assigned (2:1 ratio; 607 Lotus:305 CoreValve). Median age was 84 years, 51% of the patients were women, and the Society of Thoracic Surgeons score was 6.8±4.1. CoreValve demonstrated lower gradients and larger aortic valve area and Doppler velocity index than Lotus at discharge; the difference decreased in subsequent follow-up up to a year (all P<0.01). Lotus had lower rates of paravalvular leak that persisted over time (P<0.05). Similar outcomes were seen when comparing each valve type by size group (small, medium, large). The hemodynamic differences between valves did not translate into worse clinical outcomes. All-cause mortality was not different between the 2 groups in any of the 3 valve sizes. When comparing patients with normal valve gradients (<20 mm Hg, n=780) with those with abnormal gradients (>20 mm Hg, n=48) in the entire patient population, all-cause mortality was not different. This was also not significant when evaluating each valve type separately. Similarly, there were no differences for aortic valve area >1.1 cm2 or <1.1 cm2 and for Doppler velocity index >0.35 or <0.35 (all P=not significant). CONCLUSIONS: Lotus had significantly greater freedom from moderate or severe paravalvular leak and smaller valve area and higher gradients than CoreValve. The hemodynamic differences were not associated with any clinical differences in the composite end point of mortality, disabling stroke, and moderate paravalvular leak or with quality of life at 1 year of follow-up. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02202434.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia , Hemodinâmica , Qualidade de Vida , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos
6.
Eur Heart J ; 39(15): 1224-1245, 2018 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-28430909

RESUMO

The VARC (Valve Academic Research Consortium) for transcatheter aortic valve replacement set the standard for selecting appropriate clinical endpoints reflecting safety and effectiveness of transcatheter devices, and defining single and composite clinical endpoints for clinical trials. No such standardization exists for circumferentially sutured surgical valve paravalvular leak (PVL) closure. This document seeks to provide core principles, appropriate clinical endpoints, and endpoint definitions to be used in clinical trials of PVL closure devices. The PVL Academic Research Consortium met to review evidence and make recommendations for assessment of disease severity, data collection, and updated endpoint definitions. A 5-class grading scheme to evaluate PVL was developed in concordance with VARC recommendations. Unresolved issues in the field are outlined. The current PVL Academic Research Consortium provides recommendations for assessment of disease severity, data collection, and endpoint definitions. Future research in the field is warranted.


Assuntos
Valva Aórtica/cirurgia , Ensaios Clínicos como Assunto/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Dispositivos de Oclusão Vascular/normas , Valva Aórtica/patologia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Ensaios Clínicos como Assunto/normas , Ecocardiografia/métodos , Determinação de Ponto Final , Próteses Valvulares Cardíacas/normas , Humanos , Avaliação de Resultados em Cuidados de Saúde , Projetos de Pesquisa , Medição de Risco , Índice de Gravidade de Doença , Suturas
7.
N Engl J Med ; 373(21): 2015-24, 2015 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-26436963

RESUMO

BACKGROUND: A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and prompted further investigation. METHODS: We analyzed data obtained from 55 patients in a clinical trial of TAVR and from two single-center registries that included 132 patients who were undergoing either TAVR or surgical aortic-valve bioprosthesis implantation. We obtained four-dimensional, volume-rendered CT scans along with data on anticoagulation and clinical outcomes (including strokes and transient ischemic attacks [TIAs]). RESULTS: Reduced leaflet motion was noted on CT in 22 of 55 patients (40%) in the clinical trial and in 17 of 132 patients (13%) in the two registries. Reduced leaflet motion was detected among patients with multiple bioprosthesis types, including transcatheter and surgical bioprostheses. Therapeutic anticoagulation with warfarin, as compared with dual antiplatelet therapy, was associated with a decreased incidence of reduced leaflet motion (0% and 55%, respectively, P=0.01 in the clinical trial; and 0% and 29%, respectively, P=0.04 in the pooled registries). In patients who were reevaluated with follow-up CT, restoration of leaflet motion was noted in all 11 patients who were receiving anticoagulation and in 1 of 10 patients who were not receiving anticoagulation (P<0.001). There was no significant difference in the incidence of stroke or TIA between patients with reduced leaflet motion and those with normal leaflet motion in the clinical trial (2 of 22 patients and 0 of 33 patients, respectively; P=0.16), although in the pooled registries, a significant difference was detected (3 of 17 patients and 1 of 115 patients, respectively; P=0.007). CONCLUSIONS: Reduced aortic-valve leaflet motion was shown in patients with bioprosthetic aortic valves. The condition resolved with therapeutic anticoagulation. The effect of this finding on clinical outcomes including stroke needs further investigation. (Funded by St. Jude Medical and Cedars-Sinai Heart Institute; Portico-IDE ClinicalTrials.gov number, NCT02000115; SAVORY registry, NCT02426307; and RESOLVE registry, NCT02318342.).


Assuntos
Anticoagulantes/uso terapêutico , Valva Aórtica/fisiopatologia , Bioprótese/efeitos adversos , Doenças das Valvas Cardíacas/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/etiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Sistema de Registros , Acidente Vascular Cerebral/etiologia
8.
Am Heart J ; 205: 1-11, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30134187

RESUMO

BACKGROUND: Patients with heart failure (HF) and symptomatic secondary mitral regurgitation (SMR) have a poor prognosis, with morbidity and mortality directly correlated with MR severity. Correction of isolated SMR with surgery is not well established in this population, and medical management remains the preferred approach in most patients. The Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) trial was designed to determine whether transcatheter mitral valve (MV) repair with the MitraClip device is safe and effective in patients with symptomatic HF and clinically significant SMR. STUDY DESIGN: The COAPT trial is a prospective, randomized, parallel-controlled, open-label multicenter study of the MitraClip device for the treatment of moderate-to-severe (3+) or severe (4+) SMR (as verified by an independent echocardiographic core laboratory) in patients with New York Heart Association class II-IVa HF despite treatment with maximally tolerated guideline-directed medical therapy (GDMT) who have been determined by the site's local heart team as not appropriate for MV surgery. A total of 614 eligible subjects were randomized in a 1:1 ratio to MV repair with the MitraClip plus GDMT versus GDMT alone. The primary effectiveness end point is recurrent HF hospitalizations through 24 months, analyzed when the last subject completes 12-month follow-up, powered to demonstrate superiority of MitraClip therapy. The primary safety end point is a composite of device-related complications at 12 months compared to a performance goal. Follow-up is ongoing, and the principal results are expected in late 2018. CONCLUSIONS: HF patients with clinically significant SMR who continue to be symptomatic despite optimal GDMT have limited treatment options and a poor prognosis. The randomized COAPT trial was designed to determine the safety and effectiveness of transcatheter MV repair with the MitraClip in symptomatic HF patients with moderate-to-severe or severe SMR.


Assuntos
Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/mortalidade , Morbidade/tendências , Estudos Prospectivos , Desenho de Prótese , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
9.
Circulation ; 134(2): 130-40, 2016 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-27400898

RESUMO

BACKGROUND: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. METHODS: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. RESULTS: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P<0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P<0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. CONCLUSIONS: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01314313.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Desenho de Equipamento , Feminino , Artéria Femoral , Humanos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/epidemiologia , Modelos de Riscos Proporcionais , Recuperação de Função Fisiológica , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Lancet ; 387(10034): 2218-25, 2016 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-27053442

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve demonstrates good 30 day clinical outcomes in patients with severe aortic stenosis who are at intermediate risk of surgical mortality. Here we report longer-term data in intermediate-risk patients given SAPIEN 3 TAVR and compare outcomes to those of intermediate-risk patients given surgical aortic valve replacement. METHODS: In the SAPIEN 3 observational study, 1077 intermediate-risk patients at 51 sites in the USA and Canada were assigned to receive TAVR with the SAPIEN 3 valve [952 [88%] via transfemoral access) between Feb 17, 2014, and Sept 3, 2014. In this population we assessed all-cause mortality and incidence of strokes, re-intervention, and aortic valve regurgitation at 1 year after implantation. Then we compared 1 year outcomes in this population with those for intermediate-risk patients treated with surgical valve replacement in the PARTNER 2A trial between Dec 23, 2011, and Nov 6, 2013, using a prespecified propensity score analysis to account for between-trial differences in baseline characteristics. The clinical events committee and echocardiographic core laboratory methods were the same for both studies. The primary endpoint was the composite of death from any cause, all strokes, and incidence of moderate or severe aortic regurgitation. We did non-inferiority (margin 7·5%) and superiority analyses in propensity score quintiles to calculate pooled weighted proportion differences for outcomes. FINDINGS: At 1 year follow-up of the SAPIEN 3 observational study, 79 of 1077 patients who initiated the TAVR procedure had died (all-cause mortality 7·4%; 6·5% in the transfemoral access subgroup), and disabling strokes had occurred in 24 (2%), aortic valve re-intervention in six (1%), and moderate or severe paravalvular regurgitation in 13 (2%). In the propensity-score analysis we included 963 patients treated with SAPIEN 3 TAVR and 747 with surgical valve replacement. For the primary composite endpoint of mortality, strokes, and moderate or severe aortic regurgitation, TAVR was both non-inferior (pooled weighted proportion difference of -9·2%; 90% CI -12·4 to -6; p<0·0001) and superior (-9·2%, 95% CI -13·0 to -5·4; p<0·0001) to surgical valve replacement. INTERPRETATION: TAVR with SAPIEN 3 in intermediate-risk patients with severe aortic stenosis is associated with low mortality, strokes, and regurgitation at 1 year. The propensity score analysis indicates a significant superiority for our composite outcome with TAVR compared with surgery, suggesting that TAVR might be the preferred treatment alternative in intermediate-risk patients. FUNDING: None.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Tempo de Internação , Masculino , Pontuação de Propensão , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade
12.
Ann Intern Med ; 164(6): 377-84, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26903039

RESUMO

BACKGROUND: Female sex is associated with poorer outcomes after surgical aortic valve replacement (SAVR). Data on sex-specific differences after transcatheter aortic valve replacement (TAVR) are conflicting. OBJECTIVE: To examine sex-specific differences in patients undergoing TAVR in the PARTNER (Placement of Aortic Transcatheter Valves) trial. DESIGN: Secondary analysis of the randomized and nonrandomized portions of the PARTNER trial. (ClinicalTrials.gov: NCT00530894). SETTING: 25 hospitals in the United States, Canada, and Germany. PATIENTS: High-risk and inoperable patients (1220 women and 1339 men). INTERVENTION: TAVR. MEASUREMENTS: Demographic characteristics, cardiac and noncardiac comorbidities, mortality, stroke, rehospitalization, vascular complications, bleeding complications, and echocardiographic valve parameters. RESULTS: At baseline, women had lower rates of hyperlipidemia, diabetes, smoking, and renal disease but higher Society of Thoracic Surgeons Predicted Risk of Mortality scores (11.9% vs. 11.1%; P < 0.001). After TAVR, women had more vascular complications (17.3% vs. 10.0%; difference, 7.29 percentage points [95% CI, 4.63 to 9.95 percentage points]; P < 0.001) and major bleeding (10.5% vs. 7.7%; difference, 2.8 percentage points [CI, 0.57 to 5.04 percentage points]; P = 0.012) but less frequent moderate and severe paravalvular regurgitation (6.0% vs. 14.3%; difference, -8.3 percentage points [CI, -11.7 to -5.0 percentage points]; P < 0.001). At 30 days, the unadjusted all-cause mortality rate (6.5% vs. 5.9%; difference, 0.6 percentage point [CI, -1.29 to 2.45 percentage points]; P = 0.52) and stroke incidence (3.8% vs. 3.0%; difference, 0.8 percentage point [CI, -0.62 to 2.19 percentage points]; P = 0.28) were similar. At 1 year, all-cause mortality was significantly lower in women than in men (19.0% vs. 25.9%; hazard ratio, 0.72 [CI, 0.61 to 0.85]; P < 0.001). LIMITATION: Secondary analysis that included nonrandomized trial data. CONCLUSION: Despite a higher incidence of vascular and bleeding complications, women having TAVR had lower mortality than men at 1 year. Thus, sex-specific risk in TAVR is the opposite of that in SAVR, for which female sex has been shown to be independently associated with an adverse prognosis. PRIMARY FUNDING SOURCE: Edwards Lifesciences.


Assuntos
Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Estudos de Coortes , Feminino , Humanos , Incidência , Masculino , Readmissão do Paciente , Hemorragia Pós-Operatória/epidemiologia , Fatores de Risco , Fatores Sexuais , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Doenças Vasculares/epidemiologia
13.
Eur Heart J ; 37(28): 2252-62, 2016 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-27190101

RESUMO

AIMS: Based on randomized trials using first-generation devices, transcatheter aortic valve replacement (TAVR) is well established in the treatment of high-risk (HR) patients with severe aortic stenosis (AS). To date, there is a paucity of adjudicated, prospective data evaluating outcomes with newer generation devices and in lower risk patients. We report early outcomes of a large, multicentre registry of inoperable, HR, and intermediate-risk (IR) patients undergoing treatment with the next-generation SAPIEN 3 transcatheter heart valve (THV). METHODS AND RESULTS: Patients with severe, symptomatic AS (583 high surgical risk or inoperable and 1078 IR) were enrolled in a multicentre, non-randomized registry at 57 sites in the USA and Canada. All patients received TAVR with the SAPIEN 3 system via transfemoral (n = 1443, 86.9%) and transapical or transaortic (n = 218, 13.1%) access routes. The rate of 30-day all-cause mortality was 2.2% in HR/inoperable patients [mean Society of Thoracic Surgeons (STS) score 8.7%] and 1.1% in IR patients (mean STS score 5.3%); cardiovascular mortality was 1.4 and 0.9%, respectively. In HR/inoperable patients, the 30-day rate of major/disabling stroke was 0.9%, major bleeding 14.0%, major vascular complications 5.1%, and requirement for permanent pacemaker 13.3%. In IR patients, the 30-day rate of major/disabling stroke was 1.0%, major bleeding 10.6%, major vascular complications 6.1%, and requirement for permanent pacemaker 10.1%. Mean overall Kansas City Cardiomyopathy Questionnaire score increased from 47.8 to 67.8 (HR/inoperable, P < 0.0001) and 54.7 to 74.0 (IR, P < 0.0001). Overall, paravalvular regurgitation at 30 days was none/trace in 55.9% of patients, mild in 40.7%, moderate in 3.4%, and severe in 0.0%. Mean gradients among patients with paired baseline and 30-day or discharge echocardiograms decreased from 45.8 mmHg at baseline to 11.4 mmHg at 30 days, while aortic valve area increased from 0.69 to 1.67 cm(2). CONCLUSIONS: The SAPIEN 3 THV system was associated with low rates of 30-day mortality and major/disabling stroke as well as low rates of moderate or severe paravalvular regurgitation. TRIAL REGISTRATION: ClinicalTrials.gov #NCT01314313.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Canadá , Cateterismo Cardíaco , Ecocardiografia , Humanos , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
14.
Mod Healthc ; 47(23): 25, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30481418

RESUMO

Academic medicine generates the knowledge every physician uses today when practicing contemporary, evidence-based medicine. To meet current challenges in healthcare, however, academic medicine must broaden its focus to include the science of how we improve the delivery of care.


Assuntos
Centros Médicos Acadêmicos , Melhoria de Qualidade/organização & administração , Qualidade da Assistência à Saúde , Integração de Sistemas , Medicina Baseada em Evidências , Estados Unidos
15.
Eur Heart J ; 36(7): 449-56, 2015 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-25273886

RESUMO

AIM: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) remains uncertain. In this analysis, we sought to evaluate the impact of varying degrees of PVR on both mortality and changes in ventricular geometry and function. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent TAVR from the randomized cohorts and continued access registries in the PARTNER trial were analysed after stratifying by severity of post-implant PVR, which was graded as none/trace in 52.9% (n = 1288), mild in 38.0% (n = 925), and moderate/severe in 9.1% (n = 221). There were significant differences in baseline clinical and echocardiographic characteristics. After TAVR, all the patients demonstrated increase in left ventricular (LV) function and reduction in the LV mass index, although the magnitude of mass regression was lower in the moderate/severe PVR group. The 30-day mortality (3.1 vs. 3.4 vs. 4.5%, P = 0.56) and stroke (3.4 vs. 3.7 vs. 2.3%, P = 0.59) were similar in all groups (none/trace, mild, and moderate/severe). At 1 year, there was increased all-cause mortality (15.9 vs. 22.2 vs. 35.1%, P < 0.0001), cardiac mortality (6.1 vs. 7.4% vs. 16.3%, P < 0.0001) and re-hospitalization (14.4 vs. 23.0 vs. 31.3%, P < 0.0001) with worsening PVR. A multivariable analysis indicated that the presence of moderate/severe PVR (HR: 2.18, 95% CI: 1.57-3.02, P < 0.0001) or mild PVR (HR: 1.37, 95% CI: 1.14-1.90, P = 0.012) was associated with higher late mortality. CONCLUSION: Differences in baseline characteristics in patients with increasing severities of PVR may increase the risk of this complication. Despite these differences, multivariable analysis demonstrated that both mild and moderate/severe PVR predicted higher 1-year mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/patologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/patologia , Ecocardiografia , Feminino , Prolapso das Valvas Cardíacas , Humanos , Masculino , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/patologia , Tamanho do Órgão , Reoperação/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
Circulation ; 128(15): 1667-74, 2013 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-24014834

RESUMO

BACKGROUND: MitraClip has been shown to reduce mitral regurgitation (MR) severity safely but to a lesser degree than surgery. No data exist on the magnitude of MR reduction necessary to reverse left ventricular (LV) and left atrial (LA) dilation in patients with severe MR. Therefore, an analysis was performed to evaluate the relationship between MR reduction and LV and LA volumes after MitraClip therapy. METHODS AND RESULTS: A total of 801 patients treated with MitraClip and 80 patients treated surgically were included. All patients had severe (3-4+) MR. MR severity, LV volumes at end-diastole and end-systole, and LA volumes were measured at baseline, discharge, 30 days, 6 months, and 1 year by an independent echocardiographic core laboratory. A linear repeated measures model was developed to determine the relationship between MR severity and time of measurement postindex procedure on longitudinal LV and LA volumes. Separate models were fit for functional MR and degenerative MR. In both degenerative and functional MR, reduction in LV volumes at end-diastole was associated with degree of residual MR at 12 months (P<0.0001). LV volumes at end-systole was significantly reduced in functional MR but not degenerative MR. LA volumes were significantly related to reduction of MR severity in both groups. CONCLUSIONS: Reduction of LV volumes at end-diastole and LA volumes, but not LV volumes at end-systole in degenerative MR, is consistent with correction of volume overload from primary MR. Reduction of all 3 measurements in functional MR demonstrates reverse remodeling when MR severity is reduced to either 1+ or 2+ by MitraClip therapy. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00209274.


Assuntos
Remodelamento Atrial/fisiologia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Remodelação Ventricular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Volume Cardíaco/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Índice de Gravidade de Doença , Resultado do Tratamento , Ultrassonografia
17.
JAMA Cardiol ; 9(1): 25-34, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37966817

RESUMO

Importance: Tafamidis has been shown to improve survival in patients with transthyretin amyloid cardiomyopathy (ATTR-CM) compared with placebo. However, its effect on cardiac function has not been fully characterized. Objective: To examine the effect of tafamidis on cardiac function in patients with ATTR-CM. Design, Setting, and Participants: This was an exploratory, post hoc analysis of the Tafamidis in Transthyretin Cardiomyopathy Clinical Trial (ATTR-ACT), a multicenter, international, double-blind, placebo-controlled phase 3 randomized clinical trial conducted from December 2013 to February 2018. The ATTR-ACT included 48 sites in 13 counties and enrolled patients aged 18 to 90 years with ATTR-CM. Data were analyzed from July 2018 to September 2023. Intervention: Patients were randomized to tafamidis meglumine, 80 mg or 20 mg, or placebo for 30 months. Main Outcomes and Measures: Patients were categorized based on left ventricular (LV) ejection fraction at enrollment as having heart failure with preserved ejection fraction (≥50%), mildly reduced ejection fraction (41% to 49%), or reduced ejection fraction (≤40%). Changes from baseline to month 30 in LV ejection fraction, LV stroke volume, LV global longitudinal strain, and the ratio of early mitral inflow velocity to septal and lateral early diastolic mitral annular velocity (E/e') were compared in patients receiving tafamidis, 80 mg, vs placebo. Results: A total of 441 patients were randomized in ATTR-ACT, and 436 patients had available echocardiographic data. Of 436 included patients, 393 (90.1%) were male, and the mean (SD) age was 74 (7) years. A total of 220 (50.5%), 119 (27.3%), and 97 (22.2%) had heart failure with preserved, mildly reduced, and reduced LV ejection fraction, respectively. Over 30 months, there was less pronounced worsening in 4 of the echocardiographic measures in patients receiving tafamidis, 80 mg (n = 176), vs placebo (n = 177) (least squares mean difference: LV stroke volume, 7.02 mL; 95% CI, 2.55-11.49; P = .002; LV global longitudinal strain, -1.02%; 95% CI, -1.73 to -0.31; P = .005; septal E/e', -3.11; 95% CI, -5.50 to -0.72; P = .01; lateral E/e', -2.35; 95% CI, -4.01 to -0.69; P = .006). Conclusions and Relevance: Compared with placebo, tafamidis, 80 mg, attenuated the decline of LV systolic and diastolic function over 30 months in patients with ATTR-CM. Approximately half of patients had mildly reduced or reduced LV ejection fraction at enrollment, suggesting that ATTR-CM should be considered as a possible diagnosis in patients with heart failure regardless of underlying LV ejection fraction. Trial Registration: ClinicalTrials.gov Identifier: NCT01994889.


Assuntos
Amiloidose , Cardiomiopatias , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Feminino , Humanos , Masculino , Cardiomiopatias/tratamento farmacológico , Insuficiência Cardíaca/tratamento farmacológico , Pré-Albumina , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
18.
Artigo em Inglês | MEDLINE | ID: mdl-38795108

RESUMO

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6 and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).

19.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316377

RESUMO

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Idoso de 80 Anos ou mais , Resultado do Tratamento , Ajuste de Prótese
20.
N Engl J Med ; 363(3): 245-56, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20647200

RESUMO

BACKGROUND: Lorcaserin is a selective serotonin 2C receptor agonist that could be useful in reducing body weight. METHODS: In this double-blind clinical trial, we randomly assigned 3182 obese or overweight adults (mean body-mass index [the weight in kilograms divided by the square of the height in meters] of 36.2) to receive lorcaserin at a dose of 10 mg, or placebo, twice daily for 52 weeks. All patients also underwent diet and exercise counseling. At week 52, patients in the placebo group continued to receive placebo but patients in the lorcaserin group were randomly reassigned to receive either placebo or lorcaserin. Primary outcomes were weight loss at 1 year and maintenance of weight loss at 2 years. Serial echocardiography was used to identify patients in whom valvulopathy (as defined by the Food and Drug Administration) developed. RESULTS: At 1 year, 55.4% of patients (883 of 1595) receiving lorcaserin and 45.1% of patients (716 of 1587) receiving placebo remained in the trial; 1553 patients continued into year 2. At 1 year, 47.5% of patients in the lorcaserin group and 20.3% in the placebo group had lost 5% or more of their body weight (P<0.001), corresponding to an average loss of 5.8+/-0.2 kg with lorcaserin and 2.2+/-0.1 kg with placebo during year 1 (P<0.001). Among the patients who received lorcaserin during year 1 and who had lost 5% or more of their baseline weight at 1 year, the loss was maintained in more patients who continued to receive lorcaserin during year 2 (67.9%) than in patients who received placebo during year 2 (50.3%, P<0.001). Among 2472 patients evaluated at 1 year and 1127 evaluated at 2 years, the rate of cardiac valvulopathy was not increased with the use of lorcaserin. Among the most frequent adverse events reported with lorcaserin were headache, dizziness, and nausea. The rates of serious adverse events in the two groups were similar. CONCLUSIONS: In conjunction with behavioral modification, lorcaserin was associated with significant weight loss and improved maintenance of weight loss, as compared with placebo. (Funded by Arena Pharmaceuticals; ClinicalTrials.gov number, NCT00395135.)


Assuntos
Fármacos Antiobesidade/uso terapêutico , Terapia Comportamental , Benzazepinas/uso terapêutico , Obesidade/tratamento farmacológico , Sobrepeso/tratamento farmacológico , Agonistas do Receptor 5-HT2 de Serotonina , Agonistas do Receptor de Serotonina/uso terapêutico , Adulto , Fármacos Antiobesidade/efeitos adversos , Benzazepinas/efeitos adversos , Pressão Sanguínea , Doenças Cardiovasculares , Terapia Combinada , Método Duplo-Cego , Feminino , Doenças das Valvas Cardíacas/epidemiologia , Humanos , Insulina/sangue , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Obesidade/terapia , Sobrepeso/fisiopatologia , Sobrepeso/terapia , Fatores de Risco , Agonistas do Receptor de Serotonina/efeitos adversos , Circunferência da Cintura , Redução de Peso/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA