Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(24): 241401, 2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37390440

RESUMO

Contemporary gravitational-wave detectors are fundamentally limited by thermal noise-due to dissipation in the mechanical elements of the test mass-and quantum noise-from the vacuum fluctuations of the optical field used to probe the test-mass position. Two other fundamental noises can in principle also limit sensitivity: test-mass quantization noise due to the zero-point fluctuation of its mechanical modes and thermal excitation of the optical field. We use the quantum fluctuation-dissipation theorem to unify all four noises. This unified picture shows precisely when test-mass quantization noise and optical thermal noise can be ignored.

2.
Sensors (Basel) ; 22(12)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35746153

RESUMO

The aim of this study was to assess the validity of electro-goniometers as a tool for recording continuous relative phase data at two joint couplings during cycling tasks at a range of cadences. Seven participants (4 male, 3 female, age: 29 ± 7 years, height: 1.76 ± 0.10 m, mass: 71.97 ± 11.57 kg) performed exercise bouts of 30 s at four prescribed cadences (60, 80, 100, 120 rev·min-1) on a stationary ergometer (Wattbike, Nottingham, UK). Measures were synchronously recorded by bi-axial electro-goniometers (Biometrics, UK) and a 12-camera motion-capture system (Qualisys, Gothenburg, Sweden), with both systems sampling at 500 Hz. Sagittal plane joint angle and joint angular velocity were recorded at the hip, knee and ankle and analysed for ten complete pedal revolutions per participant per condition. Data were interpolated to 100 time points and used to calculate mean continuous relative phase (CRP) per pedal revolution at two intra-limb couplings: (i) knee flexion/extension-ankle plantarflexion/dorsiflexion (KA) and (ii) hip flexion/extension-knee flexion/extension (HK). At the KA coupling, significant differences in mean CRP were found between measurement systems at 120 rev·min-1 (p = 0.006). At the HK coupling, significant differences in mean CRP were found between measurement systems at 80 rev·min-1 (p = 0.043) and 100 rev·min-1 (p = 0.028). ICC values for most comparisons were below 0.5, suggesting poor levels of agreement between systems. Significant differences in mean CRP per pedal revolution and poor levels of agreement between systems suggests that electro-goniometers are not a suitable alternative to motion-capture systems when attempting to record CRP during cycling.


Assuntos
Articulação do Tornozelo , Ciclismo , Adulto , Fenômenos Biomecânicos , Exercício Físico , Feminino , Humanos , Articulação do Joelho , Masculino , Amplitude de Movimento Articular , Adulto Jovem
3.
Science ; 372(6548): 1333-1336, 2021 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-34140386

RESUMO

The motion of a mechanical object, even a human-sized object, should be governed by the rules of quantum mechanics. Coaxing them into a quantum state is, however, difficult because the thermal environment masks any quantum signature of the object's motion. The thermal environment also masks the effects of proposed modifications of quantum mechanics at large mass scales. We prepared the center-of-mass motion of a 10-kilogram mechanical oscillator in a state with an average phonon occupation of 10.8. The reduction in temperature, from room temperature to 77 nanokelvin, is commensurate with an 11 orders-of-magnitude suppression of quantum back-action by feedback and a 13 orders-of-magnitude increase in the mass of an object prepared close to its motional ground state. Our approach will enable the possibility of probing gravity on massive quantum systems.

4.
Sports (Basel) ; 6(3)2018 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-30189585

RESUMO

The use of mobile power measuring devices has become widespread within cycling, with a number of manufacturers now offering power measuring pedals. This study aimed to investigate the validity of PowerTap P1 pedals by comparing them with the previously validated Wattbike ergometer. Ten trained cyclists performed three simulated 10-mile (16-km) time trials on a Wattbike, while using PowerTap P1 pedals. There were no statistically significant differences (p > 0.05) between PowerTap P1 pedals and a Wattbike for maximum, minimum, and mean power output, or for maximum, minimum, and mean cadence. There were good to excellent levels of agreement between the PowerTap P1 pedals and Wattbike (ICC > 0.8) for all measured variables except minimum cadence (ICC = 0.619). This suggests that PowerTap P1 pedals provide a valid measurement of power output.

5.
Ann N Y Acad Sci ; 1098: 252-66, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17435133

RESUMO

Humans emit a complex array of volatile and nonvolatile molecules that are influenced by an individual's genetics, health, diet, and stress. Olfaction is the most ancient of our distal senses and may be used to evaluate food and environmental toxins as well as recognize kin and potential predators. Many body odors evolved to be olfactory messengers, which convey information between individuals. Consequently, those practicing the healing arts have used olfaction to aid in their diagnosis of disease since the dawn of medical practice. Studies using modern instrumental analyses have focused upon analysis of breath volatiles for biomarkers of internal diseases. In these studies, a subject's oral health status appears to seldom be considered. However, saliva and properly collected alveolar air samples must pass over or come in contact with the posterior dorsal surface of the tongue, a site of bacterial plaque development and source of halitosis-related volatiles. Because of our basic research into the nature of human body odors, our lab has received referrals of people with idiopathic malodor production, from either the oral cavity or body. We developed a protocol to help differentiate individuals with chronic halitosis from those with the genetic, odor-producing metabolic disorder trimethylaminuria (TMAU). In our referred population, TMAU is the largest cause of undiagnosed body odor. Many TMAU-positive individuals present with oral symptoms of dysguesia and halitosis as well as body odor. We present data regarding the presentation of our referred subjects as well as the analytical results from a small number of these subjects regarding their oral levels of halitosis-related malodorants and trimethylamine.


Assuntos
Biomarcadores/análise , Testes Respiratórios , Odorantes/análise , Halitose/diagnóstico , Halitose/metabolismo , Humanos , Metilaminas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA